Report Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
( ,c , am the general contractor or the owner-builder
at the following address:
Site Address:
City:
Permit#:
Subdivision/Lot#:
and/or
Map and Tax Lot#:
To conform with the 2008 Oregon Residential Specialty Code(ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
(Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes, the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
(
Signature:
Date: (;.
-ta-grat tracto)or Owner-Builder
lAttuildinifferrrARES-MotstureSensilaveWood.doc o9r2s18
- -
Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
1-7:\ , am the general contractor or the owner-builder
at the following address:
Site Address:
1L1cL33
City:
Permit#: a. ) CD, 3 I
Subdivision/Lot#:
and/or
Map and Tax Lot#:
To conform with the 2014 Oregon Residential Specialty Code(ORSC), Section R408.1
Ventilation. I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
ErThe ground surface of the under-floor space is covered with 6-nail black polyethylene
sheeting with
L....9loints lapped 12"at seams and
M- tending up the foundation walls 12".
7""
Signatur0: c Date: (..,./7 z/
G ' • or Owner-Builder
IABuildinifform\RES-MoistureBarriendoc 09/13/2016
Oregon Residential Specialty Code N1107.2
HIGII—EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: A )1 1 Jurisdiction: —
-
Site Address:
SL cA
— —e_
Subdivision/Lot#:
and/or
Map and Tax Lot#:
By my signature below, I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code N1107.2)I
Signature: .
Date: i-v7,7cci raj
tractor/Authoriied Agent
Print Name: nAr,-, c,
ORSC Section N11072.High-efficiency interior lighting systems. A minimum of fifty(50)percent a the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that
has a minimum efficacy of 40 lumens per input watt Screw-in compact fluorescent lamps comply with this
requirement.
The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per
input watt.
I ABuilding\Forms\ ghEfficiency Lighting Ax 07/01/08
Moffet Energy Modeling
CCB#223372
Phone: 916-342-0742
tyler@moffetco.com
Blower Door Test Affidavit
Permit#: Builder: Taylor Morrison
Site Address: Roshak Lot 83: 14433 SW 169th Ave,Tigard, OR 97224
Conditioned Floor Area (sq.ft.): 1554
Source: Calculated from plans Calculated Building Volume (cubic feet): 14970
TEST RESULTS: 1155 CFM @ 50 Pa
ACH @ 50 Pa = {(CFM x 60)_Volume}: 4.63
Ring: Open 0 B
Minneapolis Blower Door and DG 700 Manometer
I certify that these building leakage rates are accurate and determined using standard BPI testing
protocol.
Company Name: Moffet Energy Modeling Technician: Tyler Moffet
Technician Signature: 1-7%''' Date: 10/28/2020