Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
FPS2O,/-Q3132 "5° RECEIVED OCT 2 6 2021 CITY OF TIGARD BUILDING DIVISION =1 �- SPRINKLERS Bulletin 013 August 2021 , c Reliable Models Fl Series Standard Response o Sprinklers N O N Model F156 Sprinkler Types Standard Upright 111 Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model F156 Recessed Sprinkler Types Upright en ent Conventional Pendent/F1/F2/FP Horizontal Sidewall Model F142, F1XLH & F128 Sprinkler Types Standard Upright Standard Pendent Model F142, F1XLH & F128 Recessed Sprinkler Vertical Sidewall Horizontal Sidewall Recessed Types Pendent/F 1/F2 Pendent/F 1/F2/FP Approval Organizations 1. Underwriters Laboratories Inc. and certified for Can- ada (cULus) 2. Factory Mutual Approvals (FM) 3. Loss Prevention Council (LPCB, UK) 4. VdS Schadenverhutung GmbH Recessed Recessed XLH Upright 5. EC Certificate: 0786-CPD-40237 (RA1314) Horizontal Sidewall Pendent/FP 0786-CPD-40253 (RA1325) 0786-CPD-40254 (RA1375) UL Listing Category4111) Sprinklers,Automatic&Open (VNIV) Product Description XLH Pendent XLH Recessea XLH Recessed The F156, F142, F1XLH & F128 Series Glass Bulb Sprin- Pendent F1/F2 Pendent FP kler combines the durability of a standard sprinkler with the The F156, F142, F1XLH & F128 Series Automatic Sprin- attractive low profile of a decorative sprinkler. Whether in- kler utilizes a 5.0 mm frangible glass bulb. The glass bulb stalled on exposed piping or in an office ceiling, it is func- consists of an accurately controlled amount of special fluid tional and attractive. hermetically sealed inside a precisely manufactured glass Beautifully versatile is the description for the Reliable Mod- capsule. This glass bulb is specially constructed to provide els F156, F142, F1XLH & F128 Series Recessed glass bulb fast thermal response. sprinkler. Recessing the F156, F142, F1XLH & F128 Series At normal temperatures, the glass bulb contains the fluid enhances its already low profile decorative appearance, in both the liquid phase and in the vapor phase. The vapor and facilitates a rapid and perfect installation. phase can be seen as a small bubble. As heat is applied, The recessed escutcheon of the Models F156, F142, the liquid expands forcing the bubble smaller and smaller F1XLH & F128 are highly adjustable. The two piece con- as the liquid pressure increases. Continued heating forces struction makes field installation a very easy and rapid task. the liquid to push out against the bulb, causing the glass to This also allows ceiling panels to later be removed without shatter, opening the waterway and allowing the deflector to shutting down the fire protection system, thus facilitating distribute the discharging water. maintenance of above ceiling services. The F156, F142, F1XLH &F128 Series Sprinkler tempera- ture rating is identified by the color of the glass bulb capsule as well as frame color where applicable. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Pintle (XLH Only) Deflector Olie lit; IL Load Screw /hasher Bulb Frame AIL Cup Pi. or 10•41. I1I 0 13FG04 Model F142, F1XLH Upright Technical data: Max. Min. Models Nominal K-Factor Response Thread Working Working Temperature Finish Size Pressure Pressure Rating F156 5.6(80 Metric) 250 PSI* 1/2"NPT See F142 4.2(60 Metric) Standard FA) 7 PSI "Temperature " See Finish Table" F1XLH 175 PSI Ratings"Table F128 2.8(40 Metric) Material Data: Frame Deflector Load Screw Pintle Cup Washer Bulb CDA Alloy 260, CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 DZR Brass CDA Alloy 220 or or or Nickel Alloy 440 or Alloy 360 Glass QM Brass or coated with PTFE Adhesive Tape CDA Alloy 510 CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 *Note: Model F156 upright, pendent, and recessed pendent sprinklers(SIN RA1325 and RA1314)are cULus Listed for 250 psi (17 bar). 2. Model F156, Upright, Pendent & Conventional Sprinklers • Model F142, F1XLH & F128 Upright & Pendent Sprinklers Installation Wrench: Model W2 Sprinkler Wrench Installation Data: Nominal Thread Nominal K-Factor Sprinkler Approval Sprinkler Identification Number Orifice Size Height Organization (SIN) US Metric Upright Pendent Standard-Upright(SSU)and endent Deflectors Marked to Indicate Position 1/2"(15mm)(1) 1/2" NPT(R1/2) 5.6 80 2.25"(57mm) 1,2,3,4, 5 RA1325(2)(3)(5)(6) RA1314(2)(3)(5)(6) '/16"(10mm) 1/2"NPT(R1/2) 4.2 60 2.25"(57mm) 1 RA1323(2)(6) RA1313(6) 3/6"(10mm) 1/2"NPT(R1/2) 2.8 40 2.25"(57mm) 1 RA1321(2)(6) RA1311(6) Conventional-Install in Upright or Pendent Position 15mm(1) '/2" NPT(R'/2) 5.6 80 57mm 3,4,5 RA1375(5) (I)Refer to Bulletin 024 for Special Response Sprinklers(F1 S5-56) (2)cULus Listed corrosion resistant(Polyester coated)sprinkler. (3)Polyester coated FM Approved sprinkler. (4) (5)Polyester coated LPCB&VdS approved sprinkler RA1325,RA1314&RA1375. (6)Electroless Nickel PTFE Plated -UL listed Corrosion Resistant . s 1 Upright Pendent Conventional Model F156, F142, F1XLH & F128 Recessed Pendent Sprinklers(') Installation Wrench: Model W4 Sprinkler Wrench Installation Data: Nominal Thread Nominal K-Factor Sprinkler Sprinkler Identification Number Orifice Size US Metric Height (SIN) 1/2"(15mm) 1/2" NPT(R1/2) 5.6 80 2.25"(57mm) RA1314(2) '/,6"(10mm) 1/2" NPT(RI/2) 4.2 60 2.25"(57mm) RA1313(2) 3/8"(10mm) 1/"NPT(RY2) 2.8 40 2.25"(57mm) RA1311(2) (/)Refer to escutcheon data table for approvals&dimensions (2)Electroless Nickel PTFE Plated -cULus listed Corrosion Resistant 2 1/4'HOLE IX4. 3/l6.0B (19.2mmJ r �l ?ir I .,.X i/2•REDUCER I L_ '1-rr==_=I Zs_ , 2 5/8'DIA.(66.1mm] 1'A 1/2'REDUCER HOLE IN CEILING 1 I NRN court RENCBOSS2 ER 1 2 5/I6'OR.[5B.7mm] —• / w.I WRENCH BOSS \ / FACE a<FlIIING CUP \ I/ 1 TO FACE OF CEILING DIMENSION II f --1 1 Ar MAXIMUMCMFON CE L J MAXIMUM RECESS T254mm] CEILING ���jj/77/T AT MINIMUM RECESS J/BT95mm] � FACE OF FITTING fJ%T 9TmmJ-`-`-'�� �jj, E:,11) f2 ESCUTCHEON III IIII TO FACE OF CEILING 11 I MariMUM RECESS-J/4q19mm] _ 1111, DIMENSION _ I AADJUSIMENI AIMINIMUM RECESS S/B(9Smm] (\ l AT MAXIMUM RECESS= 1 1/27JBmm] F2 ESCUTCHEON _�`i II 'i,,,% \_ Ai MINIMUM RECESS= 1725.4mmj J Il UIII�� I`I���I 1/2T12Tmm l AF1 ES MUMHEON AD/usrMENr ,;//% III � ) I/e• MAX RECEss=2/e7zzzmm) �t � PEAR.] AT MINIMUM RECESS-15/B14I.Smm) 1 ,$' "I/ ,�1"��� F2 ESfUTCHFON J `,•: �� AT MAXIMUM RECESS=9/16714.Jmm] Nike T MAXIMUM RECESS= Sz750.emm] ..M�!% AT MINIMUM RECESS= 1 725.4mm] •• I-I/872B.6mm] �,1111,!� AI MINIMUM RECESS-1-5/BT41.Smm] ADJUSTMENT . I .- 2(R.2m /J2'm) [82.6mm] OIJTW IC RECESSED PENDENT W/F1 OR F2 ESCUTCHEON RECESSED PENDENT W/FP ESCUTCHEON MI,FSA2R 'SPRINKLER NOT FM APPROVED MMTH FI ESCUTCHEON 'SPRINKLER NOT FM APPROVED WITH FP ESCUTCHEON Model F156, F142, F1XLH&F128 F1 or F2 Model F156, F142, F1XLH&F128 FP 3. • Model F156 Vertical Sidewall Sprinkler Installation Wrench: Model W2 Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy U.S. Patent No. 6,374,920 Sprinkler Type Deflector to Ceiling Distance (Min.-Max.) Upright 4"(102mm)-12"(305mm) Pendent 4"(102mm)-12"(305mm) Installation Data: Vertical Sidewall Nominal Nominal K Factor Sprinkler Approval(1) Sprinkler Orifice Thread Size Height Organizations Identification US Metric gNumbers(SIN) 1/2"(15mm) 1/2"NPT(R1/2) 5.6 80 2.25"(57mm) 1,2,3 RA1385(1)(2)(3)(4) (1)LPC Approval is pendent only,57°C through 141°C ratings. (2)cULus Listed corrosion resistant(Polyester coated)sprinkler. (3)cULus Listed&FM Approved corrosion resistant for lead,wax and wax over lead. (4)Electroless Nickel PTFE Plated -cULus listed Corrosion Resistant Model F156 Horizontal Sidewall Sprinkler Deflector:HSW Installation Wrench:Model W2 Sprinkler Wrench FACE OF FITTING r0 FACE OF CEILING DIMENSION FI EScurCHEon j' FIAT MAXIMUM RECESS = 1 725.4mm]AT MINIMUM RECESS = 3/8[95mm] ESCUTCHEON F2 ESCUTCHEON AT MAXIMUM RECESS = 1-3/8 734.9mm] AT MAXIMUM RECESS = 3/4[19mm] AT MINIMUM RECESS =2-1/16(52.4mm] AT MINIMUM RECESS = 3/8.9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS= 1-5/8[41.3mm] 2 1/4"HOLE DIA. AT MINIMUM RECESS = 2-1/16[52.4mm] [57.2mm) [3.12m/8"m] 1"X 1/2"REDUCER ,(/ J r'- ^) (I) 1 15/16"DIA.11IiLN [101.6mm-304.8mm] [49.2mm] om 2 27/32"DIA. CEILING TO [72.2mm] DEFLECTOR L_L TURN COLLAR UNTIL � I WREN TIGHT CH BO AGAINSTSS SPRINKLER \N F1 ESCUTCHEON 3/4[19mm]ADJUSTMENT —+j F2 ESCUTCHEON 1/2[12.7mm]ADJUSTMENT RECESSED HSW W/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4"- 6"[101.6MM - 152.4MM]CEILING TO DEFLECTOR. Horizontal Sidewall Note:For Recessed HSW Sprinklers use installation wrench W4.FM and cULus permits use with Fl or F2 escutcheons for"Light Hazard"only. Installation Data: Horizontal Sidewall Nominal K Factor Sprinkler A roval Organizations Height pp g Sprinkler g Nominal Orifice Thread Size Identification US Metric Light Hazard Ordinary Numbers(SIN) Hazard 1/2"(15mm) 1/2"NPT(R1/2) 5.6 80 2.63"(67mm) 1,2 1 RA1335(1)(2)(3)(4) (1)cULus Listed corrosion resistant(Polyester coated)sprinkler. (2)cULus Listed&FM Approved corrosion resistant for lead,wax and wax over lead. (3)Polyester coated FM approved sprinkler. (4)Electroless Nickel PTFE Plated -cULus listed Corrosion Resistant 4. Application Maintenance Model F156, F142, F1XLH, F128 & Model F156, F142, The Model F156, F142, F1XLH &Model F156, F142, F1X- F1XLH & F128 Recessed sprinklers are used in fixed fire LH & F128 Recessed Sprinklers should be inspected and protection systems: Wet, Dry, Deluge or Preaction. Care the sprinkler system maintained in accordance with NFPA must exercised that the orifice size, temperature rating, de- 25. Do not clean sprinklers with soap and water, ammonia flector style and sprinkler type are in accordance with the or any other cleaning fluid. Replace any sprinkler which has latest published standards of the National Fire Protection been painted (other than factory applied)or damaged in any Association or the approving Authority Having Jurisdiction way. A stock of spare sprinklers should be maintained to al- Installation. low quick replacement of damaged or operated sprinklers. Installation Prior to installation, sprinklers should be maintained in the Model F156, F142, F1XLH & F128 Series sprinklers are original cartons and packaging until used to minimize the standard response sprinklers intended for installation as potential for damage to sprinklers that would cause improp- specified in NFPA 13. They must also be installed with the er operation or non-operation. Model W2 Sprinkler Wrench specifically designed by Reli- Temperature Ratings able for use with these sprinklers. Sprinkler Max.Ambient Bulb The Model F156, F142, F1XLH & F128 Recessed Sprin- Classification ,� ,F Temperature Temp. Color klers are to be installed with a maximum recess of 3/4 inch Ordinary 57 135 100°F(38°C) Orange (19mm). The Model F1, F2, and FP Escutcheon illustrated Ordinary 68 155 100°F(38°C) Red are the only recessed escutcheon to be used with the Model Intermediate 79 175 150°F(66°C) Yellow F156, F142, F1XLH & F128 Recessed Sprinklers. The use Intermediate 93 200 150°F(66°C) Green of any other recessed escutcheon will void all approvals and High'> 141 286 225°F(107°C) Blue negate all warranties. When installingModel F156, F142, Extra High 2160 500 47 300°F(149°C) Mauve g Ultra High r�c2� 260 500 475°F(246°C) Black F1XLH & F128 Recessed Sprinklers use the Model W4 1 Not available for recessed Sprinklers. Sprinkler Wrench. Any other type of wrench may damage (2)cULus listed for SIN RA1325 and RA1314 only. these sprinklers. Maximum Working Pressure Note: A leak tight '/2" NPT (RY2) sprinkler joint can be ob- 175 psi (12 bar) tained with a torque of 8 - 18 ft-lbs (11 - 24 N-m). Do not SIN RA1325 & RA1314 cULus listed for 250 psi (17 bar) tighten sprinklers over maximum recommended torque. It 100% Factory tested hydrostatically to 500 psi (34.5 bar) may cause leakage or impairment of the sprinklers. Glass bulb sprinklers have orange covers to protect the Finisht') Standard Finishes bulb during the installation process. REMOVE THIS PRO- Sprinkler Escutcheon TECTION ONLY AFTER THE SYSTEM HAS BEEN HYDRO- Bronze Brass Chrome Chrome STATICALLY TESTED AND, WHEN APPLICABLE, THE ES- Polyester Coated(6)(7)(9) White Painted CUTCHEONS HAVE BEEN INSTALLED. RASCO wrenches Special Application Finishes are designed to install sprinklers when covers are in place. Sprinkler 3 ° Escutcheon Electroless Nickel PTFE Electroless Nickel PTFE Ordering Information Bright Brass(2) Bright Brass Specify: Black Plated Black Plated 1. Sprinkler Model Black Paint131191 Black Paint 2. Sprinkler Type Off White131191 Off White 3. Nominal K-Factor Chrome Dull Chrome Dull 4. Temperature Rating Lead Plated13114>18> 5. Sprinkler Finish Wax Coated(3)(4)(5i") 6. Thread Type: [1/2" NPT] [ISO 7-1 R'h] Wax Over Lead 3 c4u5>ce> 7. Escutcheon Finish (where applicable) 1)Other colors and finishes are available on special order.Consult factory Note:When Models F156,F142,F1XLH&F128 Recessed Sprinklers are for details.Custom color painted sprinklers may not retain their UL Cor- ordered,the sprinklers and escutcheons are packaged separately. rosion resistance listing. 21200°F(93°C)maximum. Escutcheon Data t'i (3)UL and ULC listed only. (4)155°F to 200°F(68°C to 93°C)ratings only. ")SIN: RA1335-cULus and FM permits use with F1 or F2 escutcheons (5)286°F(141°C)sprinklers may be coated for ambient conditions not ex- for light hazard only. ceeding 150°F(66°C). (6)cULus listed "corrosion resistant" applies to SIN Number RA1325 (Upright) RA1323 (upright), RA1321(Upright), RA1335 (HSW), RA1385(VSW)and RA1314 (Pendent)in standard black or white. Cor- rosion resistance in other polyester colors is available upon request. (7) FM Approved finish as "Polyester Coated" applies to SIN number RA1314,RA1335&RA1325 in standard black or white. (8)FM Approved finish applies only to SIN number RA1335&RA1385. (9) LPCB and VdS Approved finish applies only to RA1325, RA1314 and RA1375. (10)cULus listed Corrosion Resistant applies to SIN RA1325 ,RA1314 ,RA1323,RA1313,RA1321,RA1311, RA1385 and RA1335 5. 'Rel iable . . . For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many pre- cision-made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gauges • Electrical sprinkler alarm switches • Identification signs • Water flow detectors • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 100 years. Manufactured by Reliable Automatic Sprinkler Co.,Inc. Recycled Y ) Sales Offices(800 Paper Reliable (800)431 848 1588051 Fax Corp (914)829-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.08/21 P/N 9999970299 PIPE - - :fig. z� _. _ _ - - _ - �_ - 1. _ `- _ _ • _ - xx • _ _ _ �_ _ _ _ _ _ SPRINKLER PIPE Trust Bull Moose when it comes to protecting your most valuable assets. As the leading manufacturer of steel sprinkler pipe, we understand that there are no second chances in fire suppression. You need products of enduring quality and exceptional strength—plus reliable service. You need Bull Moose. • UL listed(US&Canada)and FM approved • We have the most stocking locations in industry,for best delivery and availability • ASTM A135 and A795 Type E, Grade A Certified • Plain end or roll groove • Complies with NFPA-13,13R and 14 • Eddy Guard II'bacterial-resistant internal coating • Industry-leading hydraulic characteristics. • Custom length options • CRR of 1.0 and greater • Hot dipped galvanization • All pipe NDT weld tested • Reddi-Pipe®red pipe to eliminate field painting Exclusive maker of Reddi-Pipe® • Compatible for use in wet,dry, preaction red painted pipe. and deluge sprinkler systems 1 A c®us LISTED d APPROVED CiO] A01, NFPA so.+nkI.A `�,®„•., ` �. . . , 800.325.4467 f BULL D/ 00SE sates bulb* 1 f w'' BullMooseTube.com Bull Moose Fire Sprinkler Pipe Product Information ,,t Nominal Pipe Size(Inches) 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 4" 6" 8" 1, O.D.(in) 1.660 1.900 2.375 2.875 3.500 4.500 I D.(in) 1.530 1.728 2.203 2.705 3.334 4.310 ',ktiE' 1.222 1.844 20 2.809 3.361 4.968 '.]..A.44]] .33 Empty Weight(Ib/ft} Water Filled Weight(lb/ft) 2.019 2.860 3.982 5.299 7.144 11.290 4 C.R.R. 1.98 3.44 2.78 1.66 1.00 1.00 <_ Pieces per Lift 61 61 37 30 19 19 Lift Weight(Ibs)21'lengths 1,565 2,362 1,810 1,770 1,341 1,982 Lift Weight(Ibs)24'lengths 1,789 2,700 2,069 2,022 1,533 2,265 Lift Weight(Ibs)25'lengths 1,864 2,812 2,155 2,107 1,596 2,360 11- O.D.(in) 1.315 1.660 1.900 2.375 2.875 3.500 4.500 6.625 8.625 I.D.(in) 1.097 1.442 1.682 2.157 2.635 3.260 4.260 6.357 8.249 ' Empty Weight(Ib/ft) 1.410 1.810 2.090 2.640 3.530 4.340 5.620 9.290 16.940 W Water Filled Weight(Ib/ft) 1.820 2.518 3.053 4.223 5.893 7.957 11.196 23.038 40.086 Ci C.R.R. 15.27 9.91 7.76 6.27 4.92 3.54 2.50 1.158 1.805 W = Pieces per Lift 91 61 61 37 30 19 19 10 7 tj 1 Lift Weight(Ibs)21'lengths 2,695 2,319 2,677 2,051 2,224 1,732 2,242 ' 1,951 2,490 Lift Weight(Ibs)24'lengths } 3,079 2,650 3,060 2,344 2,542 1,979 2,563 2,230 2,848 Lift Weight(Ibs)25'lengths 3,208 2,760 3,187 1 2,442 2,648 2,062 2,670 D.D.(in) 1.295 1.650 1.900 2.375 G , I.D.(in) 1.083 1.418 1.645 2.123 r.T ; O Empty Weight(Ib/ft) G 1.461 2.070 2.547 3.308 'Q Water Filled Weight(Ib/ft) 1.860 2.754 3.468 4.842 W , CZ C R.R. 1.00 1.00 1.00_._... 1.00 F-- Pieces per Lift 1 70 51 44 30 G Lift Weight(Ibs)21'lengths j 2,148 2,217 2,353 2,084 W lift Weight(Ibs)24'lengths 2,454 2,534 2,690 2,382 Lift Weight(Ibs)25'lengths 2,557 2,639 2,802 2,481 0.D.(in) 1.315 1.660 1.900 2.375 2.875 3.500 4.500 `` I.D.(in) 1.049 1.380 1.610 2.067 2.469 3.068 4.026 Empty Weight)Ib/ft) 1.680 2.270 2.720 3.660 5.800 7.580 10.800 Water Filled Weight(Ib/ft) 2.055 2.918 3.602 5.114 7.875 10.783 16.316 C R.R. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Pieces per Lift 70 51 44 30 30 19 19 Lift Weight(Ibs)21'lengths 2,470 2,431 2,513 2,306 3,654 3,024 4,309 Lift Weight(Ibs)24'lengths 2,822 2,718 2,872 2,635 4,176 3,456 4,925 Lift Weight(Ibs)25 lengths j 2,940 2,894 2,992 2,745 4,350 3,601 5,130 . fki,Z, ii.SPO 1:OO.325.446 ', BULL lYEOOSE sales@,bullmooSe)tlils i• `i : u IMooseTube.com GROOVED FITTINGS FireLock® Rigid Coupling Style 005H ictaulic° with Vic-Plus' Gasket System 10.02 Material Specifications: Housing: Ductile iron conforming to ASTM A-536, grade 111, 1114;ii 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Patented Exaggerated for clarity Housing Coating: (specify choice) &PittS Standard: Orange enamel (North America); red t System enamel (Europe) ❑ Optional: Hot dipped galvanized Approvals/Listings: LPCB Coupling Gasket: (specify choice) FM �P VdS NOTE:Additional gasket styles are available.Contact Victaulic for details. USTED 104-1a/02 See Victaulic Publication 10.01 for more details. ❑ Grade "E" EPDM Type A Vic-PlusT° Gasket System' LPC and VdS Approved,see notes on page 3 EPDM (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc.and Approved by Factory Mutual Research for wet and dry(oil free air) Product Description: sprinkler services up to the rated working pressure using the Grade"E"Type A Vic-Plus'"'Gasket System, requiring no field FireLock Style 005H rigid coupling has a unique, lubrication for most installation conditions. patented angle-pad design which allows the housings ❑ Grade "L" silicone to offset while clamping the grooves. By permitting the housings to slide on the angled bolt pads, rigidity is Recommended for dry heat,air without hydrocarbons to obtained. +350°F and certain chemical services. Support and hanging requirements correspond to For dry services, Victaulic continues to recommend the NFPA 13 Sprinkler Systems. Angle-pad design permits use of Grade "E" Type A FlushSeal®Gasket. assembly by removing one nut/bolt and swinging the Contact Victaulic for details. housing over the gasket. This reduces components to handle during assembly. Bolts/Nuts: Heat-treated plated carbon steel, trackhead Style 005H FireLock coupling are designed and meeting the physical and chemical requirements of recommended for use ONLY on fire protection systems. ASTM A-449 and physical requirements of ASTM A-183. Standard gasket and FlushSeal gasket approved for dry pipe systems to Vic-Plus'" Gasket System: —40°F/-40°C.Based on"typical"pipe surface conditions,supplemental lubricant is recommended for services installed below 0°F/-18°C and Victaulic offers a gasket system which requires no field for all dry pipe systems or systems to be subjected to air tests prior to lubrication on wet pipe systems that are hydrostatically being filled with water.Supplemental lubrication may also be required on tested. The Vic-Plus System (patented) is dry, clean, pipe with raised or undercut weld seams or pipe that has voids and/or cracks at the weld seams.Victaulic continues to recommend the use of and non-toxic. It reduces assembly time substantially FlushSeal gaskets for dry services. and eliminates the mess and chance of over-lubrication. Please refer to the latest copy of the Victaulic Field Installation Handbook (1-100) for supplemental lubrication requirements and dry pipe fire protection system notes. Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Couplings I Rigid I Style 005H I Publication 10.02 10.02 1538 Rev M Updated 10/2014 ©2014 Victaulic Company.All rights reserved. 1 jctaullc° victaulic.com I Couplings I Rigid I Style 005H I Publication 10.02 Dimensions: < Y �z--> Rated for wet and dry sprinkler systems at 350 psi/2413 kPa � i����i for 1 V4-4'/32-100 mm sizes and 300 psi/2068 kPa for ,, akeirr� -. 4 V4-87108-200 mm sizes;Schedule 10 roll grooved or J(�' �J Schedule 40 cut or roll grooved steel pipe.Style 005H is rigid t� '1 II and does not accommodate expansion,contraction or angular �J-�J deflection. Actual Maximum Maximum I Allow. Approx. Nominal Outside Working End Pipe End Dimensions Weight Size Diameter Pressure14 Load' Separation2 Bolt/Nut3 X Y Z Each inches inches psi lbs. inches No.-size inches inches inches lbs. mm mm kPa N mm inches mm mm mm kg 1 /4 1.660 350 755 0.05 2.75 4.50 1.88 1.2 32 42.4 2413 3370 1.2 2 '/°x 2'/4 70 114 48 0.5 11/2 1.900 350 990 0.05 3.00 4.75 1.88 1.2 40 48.3 2413 4415 1.2 2 3/8 x 2'/4 76 121 48 0.5 2 2.375 350 1550 0.07 3.50 5.25 1.88 1.6 50 60.3 2413 6900 1.7 2 3/8 x 21/2 89 133 48 0.7 21/2 2.875 350 2270 0.07 4.00 5.75 1.88 1.9 65 73.0 2413 10110 1.7 2 3/8 x 21/2 102 146 48 .09 3.000 350 2475 0.07 4.13 5.75 1.88 1.9 76.1 mm 76.1 2413 11010 1.7 2 '/°x 2'/z 105 146 48 0.9 3 3.500 350 3365 0.07 4.63 6.13 1.88 2.1 80 88.9 2413 14985 1.7 2 3/8 x 2'/2 118 156 48 1.0 4 4.500 350 5565 0.16 5.75 7.25 2.13 3.1 100 114.3 2413 24770 4.1 2 '/8 x 2'/z 146 184 54 1.4 4.250 300 4255 0.16 5.63 7.25 2.13 3.1 108.0 mm 108.0 2068 18940 4.1 2 3/°x 2'/z 143 184 54 1.4 5 5.563 300 7290 0.16 6.88 9.00 2.13 4.5 125 141.3 2068 32445 4.1 2 1/2 x 3 175 229 54 2.0 . 5.250 300 6495 0.16 6.63 9.00 2.13 4.5 133.0mm 133.0 2068 28900 4.1 2 1/2 x 23/a 168 229 54 2.0 5.500 300 7125 0.16 6.88 9.00 2.13 4.8 139.7mm 139.7 2068 31715 4.1 2 '/zx23/° 175 229 54 2.2 6 6.625 300 10340 0.16 8.00 10.00 2.13 5.0 150 168.3 2068 46020 4.1 2-1/2 x 3 203 254 53 2.3 6.250 300 9200 0.16 7.63 10.00 2.13 5.5 159.0 mm 159.0 2068 40955 4.1 2-1/2 x 2 3/" 194 254 54 2.5 6.500 300 9955 0.16 8.15 10.00 2.13 5.5 165.1 mm 165.1 2068 44295 4.1 2-1/2 x 3 207 254 54 2.5 8 8.625 300 17525 0.19 10.50 13.14 2.63 11.3 200 219.1 2068 78000 4.8 2 5/a x 43/4 267 334 67 5.1 1 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Contact Victaulic for performance on other pipe.WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. 2 The allowable pipe separation dimension shown is for system layout purposes only.Style 005H couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. 3 Number of bolts required equals number of housing segments.Metric thread size bolts are available(color coded gold)for all coupling sizes upon request. Contact Victaulic for details. 4 Style 005H couplings are VdS and LPC Approved to 16 Bar/235 psi. 10.02 1538 Rev M Updated 10/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 2 :ctauI.c' victaulic.com I Couplings I Rigid I Style 005H I Publication 10.02 Listings/Approvals: The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Related Working Pressure Related Working Pressure Related Working Pressure psi psi psi Pipe Size Pipe Size Pipe Size Sch. inches UL ULC FM Sch. inches UL ULC FM Sch. inches UL ULC FM 5 11/4-3 175 175 175 EL 1'/a-2 300 N/A N/A MT 11/4-2 300 N/A i N/A 1'/4-3 350 350 350 ET 11/4-2 300 N/A N/A STF 1'/4-4 N/A N/A 300 10,40 5-8 300 300 300 EZ 4-6 3006 N/A 300 Steady- 11/4-2 N/A N/A 300 BLT 11/4-2 300 300 N/A FF 1'A-4 N/A N/A 300 TF 3-8 N/A N/A 300 DF 1 Y-4 300 300 300 GAL-7 1'/4-2 300 N/A N/A WLS 1 Y-2 300 300 N/A DT 1 Y4-2 300 300 N/A MLT 1 Y4-2 300 N/A N/A XL 1 Y-3 300 300 300 L EF 13/4-4 1757 N/A 175 MF 1'/4-4 300 N/A 3005 5 FM approved for service in 1 1/2-4"pipe. 6 UL Listed for service up to 4"pipe only. 7 UL Listed for service up to 3"only. Installation Note Reference should always be made to the 1-100 Victaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Victaulic specifications.All products the product you are installing.Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data,and are available in PDF format Victaulic reserves the right to change product specifications,designs and standard on our website at www.victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic®is a registered trademark of Victaulic Company. 10.02 1538 Rev M Updated 10/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 3 ✓ctaul.c' CARBON STEEL PIPE - GROOVED FITTINGS 07.01 Grooved End Fittings ® ® �S• LPCB• SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Victaulic offers a broad line of fittings in sizes through 48"/1200mm in a variety of straight and reducing styles.Most standard fittings are cast of durable ductile iron to precise tolerances. 40010"141. - Victaulic standard fittings pressure ratings conform to the ratings of Victaulic Style 77 couplings. All fittings are supplied with grooves or shoulders to permit fast installation without field preparation. The grooved design permits flexibility for easy alignment. These fittings are not intended for use with Victaulic couplings for plain end pipe(refer to Section 14.04 for fittings available for plain end applications). Fittings are provided in various materials including ductile iron,steel or segmentally welded steel NO.20 TEE depending on styles and size.Fittings are painted orange enamel with a galvanized finish available as an option,contact Victaulic for details. Victaulic fittings are designed specifically for use in grooved piping systems.Fittings are provided ;.. grooved or with shoulders conforming to standard steel pipe outside diameters.When connecting wafer or lug-type butterfly valves directly to Victaulic fittings with 741 or 743 Vic-Flange®adapters, check disc clearance dimensions with I.D.dimension of fitting. Note:The followingVictaulic fittings are VdS approved:NO.10 90"Elbow,NO.11 45"Elbow,NO.20 g pP Tee and NO.60 Cap. Note:The following Victaulic fittings are LPCB approved:NO.10 90"Elbow,NO.11 45"Elbow, NO.12 221 "Elbow,NO.13 111/4"Elbow,NO.30 45"Lateral,NO.30-R Reducing Lateral,NO.100 No.10 ELBOW Long Radius Elbow,NO.110 Long Radius Elbow,NO.20 Tee,NO.35 Cross,NO.60 Cap,NO.25 Reducing Tee,NO.33 True Wye,NO.50 Concentric Reducer,NO.51 Eccentric Reducer,NO.29M Tee with Threaded Branch,NO.27 Standpipe Tee,and NO.32 Tee Wye. Advanced Groove System-For 14-24"/350-600mm piping systems,Victaulic now offers the -. Advanced Groove System(AGS).Refer to Section 20.05 for AGS fitting details. Stainless Steel-Grooved end fittings are available in Schedule 10 Type 316 stainless steel(Schedule 5,40 and Type 304 available as an option)in various sizes.Fitting center-to-end dimensions will vary depending upon type and schedule.Refer to Section 17.04 and 17.16 for details. Aluminum-Grooved end fittings are available in aluminum alloy 356 T6,in sizes from 1-8'/25-200mm.Refer to Section 21.03 or contact Victaulic for details. AGS-ADVANCED GROOVE SYSTEM ALTERNATE STYLES Extra Heavy EndSeal®"ES"Fittings-EndSeal fittings are available in 2-12"/50-300mm for use with"ES"grooved pipe and HP-70ES EndSeal couplings."ES"fittings are painted black for easy identification.EndSeal(and standard)fittings may be easily internally coated(by others)for severe service requirements.Always specify"ES EndSeal fittings"when ordering.See Section 07.03 for information on EndSeal fittings. Fittings Machined for Rubber or Urethane Lining(MRL)-For severe abrasive services,Victaulic fittings may be rubber or urethane lined(by others).Lining may be inside diameter/end(abrasion resistance)or wrap-around(corrosion and/or abrasion)machined.Refer to Section 25.03 or contact Victaulic for specific details. Note:Fittings are available with a variety of coatings upon request such as hot dip galvanized,epoxy, glass lined and others. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICtaUI.C' REV_N 07.01_1 CARBON STEEL PIPE-GROOVED FITTINGS 07.0 1 Grooved End Fittings MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. • Or: Segmentally welded steel as shown under nipples Nipples: (adapter,swaged&hose) • 3/4-4'/20-100mm:Carbon steel, Schedule 40,conforming to ASTM A-53,Type F • 5-6'/125- 150mm:Carbon steel, Schedule 40,conforming to ASTM A-53,Type E or S, Gr. B • 8- 12'/200-300 mm: Carbon steel, Schedule 30 or 40, conforming to ASTM A-53,Type E or S, Gr. B Flanged Adapter Nipples: (Nipple-see above) • Class 125 Flange:Cast iron conforming to ANSI B-16.1 • Class 150 Flange:Carbon steel conforming to ANSI B-16.5, raised or flat face • Class 300 Flange:Carbon steel conforming to ANSI B-16.5, raised or flat face Fitting Coatings:Orange enamel • Optional: Hot dip galvanized and others. Some fittings supplied electroplated as standard-see product specifications. Flanged Adapter Nipple Coating: None(Unfinished) • Optional: Orange enamel, hot dip galvanized and others. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. •Cta'11.1lIC' 0701 2 , CARBON STEEL PIPE-GROOVED FITTINGS 07.01 Grooved End Fittings FLOW DATA The chart expresses the frictional resistance of various Victaulic fittings as equivalent feet of straight (Frictional Resistance) pipe.Fittings not listed can be estimated from the data given,for example,a 22r/z°elbow is approximately one-half the resistance of a 45°elbow.Values of mid-sizes can be interpolated. Size Dimension-Feet/meters Elbows Tees 90°Elbows 45°Elbows Actual No.100 No.110 Nominal Outside No.10 1' D No.11 11/2 D Size Dia. Std. Long Std. Long In./mm In./mm Radius Radius Radius Radius Branch Run 1 1.315 1.7 0.8 4.2 1.7 25 33.7 0.5 0.2 1.3 0.5 2 2.375 3.5 2.5 1.8 1.1 8.5 35 50 60.3 1.1 0.8 0.5 0.3 2.6 1.1 76.1 mm 3.000 4.3 - 2.1 10.8 4.3 76.1 1.3 0.7 3.3 1.3 3 3.500 5.0 3.8 2.6 1.6 13.0 5.0 80 88.9 1.5 1.2 0.8 0.5 4.0 1.5 108.0 mm 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 5.0 3.4 2.1 16.0 6.8 100 114.3 2.1 1.5 1.0 0.6 4.9 2.1 133.0 mm 5.250 8.1 4.1 20.0 8.1 133.0 2.5 1.2 6.2 2.5 139.7 mm 5.500 8.5 4.2 21.0 8.5 - 139.7 26 1.3 6.4 2.6 5 5 563 8.5 _ 4.2 - 21.0 8.5 125 141.3 2.6 1.3 6.4 2.6 159.0 mm 6.250 9.4 - 4.9 _ 25.0 9.6 159.0 2.9 1.5 7.6 2.9 165.1 mm 6.500 9.6 - 5.0 25.0 10.0 - 165.1 2.9 1.5 7.6 3.0 6 6.625 10.0 7.5 5.0 3.0 25.0 10.0 150 168.3 3.0 2.3 1.5 0.9 7.6 3.0 8 8.625 13.0 9.8 6.5 4.0 33.0 13.0 200 219.1 4.0 3.0 2.0 1.2 10.1 4.0 10 10.750 17.0 12.0 8.3 5.0 41.0 17.0 250 273.0 5.2 3.7 2.5 1.5 12.5 5.2 12 12.750 20.0 14.5 10.0 6.0 50.0 20.0 300 323.9 6.1 4.4 3.0 1.8 15.2 6.1 14 14.000 24.5§ 15.8 18.5 5 11.0 70.0 23.0 350 355.6 z5 4.8 5.6 3.4 21.3 7.0 16 16.000 28.0§ 18.0 21.0 4 13.0 80.0 27.0 400 406.4 8.5 5.5 6.4 4.0 24.4 8.2 18 18.000 31.0§ 20.0 23.5§ 14.0 90.0 30.0 450 457.0 9.5 6.1 7.2 4.3 27.4 9.1 20 20.000 34.0 4 22.5 25.5§ 16.0 100.0 33.0 800 508.0 101 6.9 7.8 4.9 30.5 10.1 24 24.000 42.0§ 27.0 29.5 4 19.0 120.0 40.0 600 610.0 128 8.2 9.0 5.8 36.6 12.2 26 26.000 28.0 20.5 130.0 43.0 650 660.4 # 8.5 # 6.3 39.6 13.1 30 30.000 34.0 24.0 150.0 50.0 750 _ 762.0 # 10.4 # 7.3 45.7 15.2 • 36 36.000 40.5 28.5 180.0 60.0 900 914 0 # 12.3 # 8.7 54.9 18.3 • 42 42.000 47.0 33.0 210.0 70.0 1050 1067.0 # 14.3 # 10.1 64.0 21.3 #Contact Victaulic for details. #For use on cut grooved systems only.For roll grooved systems,Victaulic offers the Advanced Groove System(AGS).For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales office. §Fitting flow data for 14-247350-600 mm size NO.10 and NO.11 Elbows is based on fittings for Style 07 and 77 couplings.For flow data on AGS fittings(NO.W10 and NO.W11 Elbows),refer to submittal 20.05. Note:All fittings are ductile iron unless otherwise noted with an"sw"or"s".SW=Segmentally Welded. 5=Carbon Steel wwwvictaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICtauI,C° REV_N 07.01.3 GROOVED FITTINGS 90° ELBOW l''!'.'ANVIL (CCE-PF Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fittings ore UL& ULC Listed& FM Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-12. Dimensions conform to ASME B16.3 Threads are NPT per ANSI/ASME B 1.20.1. NOTICE:Duthie iron fittings have higher tensile strength than that of steed pipe.Therefore,over tightening earl case damage to pipe threads which may cause leakage.Ductile iron fittings should be tightened three turns beyond hand tight,but no more than tour turns C®M fM Il EI APPROVED forLarWrastatarreirtei area aria Umtata*. 9 0} ELBOW resa+ag falai+s Iracenatia n a Nominal Size Max.Working Dimensions Approx. Pressure. A B Wt.Each A in,(it a FSt Ore; la,Carl i4 Ow) fbx Ck) 1 500 1.50 1.50 0.62 20 3$.10 11 500 1.15 1.15 0,90 t -r- 3a51� 44 di 44.45 ad B 14 500 1.94 1.94 1.20 I m= 2 S00 2.25 2.25 1.85 Si t5 ♦-Working Pressure Ronegs ore for ref m net only and based art Sch.40 pipe For she knell ULIULC. and FM pressure ratings rernun tape schedule,pfeose visit oavitinii core or contact your local Anvil Representohve f441/4,-sr)AN/ L REV 45.12-10 www.anvilintLcam STRAIGHT TEE z AnwiL (C /ww ) Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fittings are Ul& ULC Listed& FM Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-12, f Dimensions conform to ASME B16.3 t ',,f j Threads are NPT per ANSI/ASME B 1.20.1. NOTICE:Ducele wars fittings have higher tensile strength than that of steel pipe.Therefore,over tightening con cause damage to pipe threads which may cause leakage Ductile iron fittin47s should be tightened three turns beyond hand tight,but no more them four turns. ltl1B APPNOWO for uaa+9rHppeew10,1 is and lm?esn s.. STRAIGHT TEE WSki our«*»..i.ar «om 1.04.10 art er r trdsa Nominal Size Moe.Working Dimensions Approx. Pressure. A 8 Wt.Each M.(asut PSI fkPo In tie A.:, s fon' tex(kqt t -- 1 ._..._ 500 �.. 1 50 t 50 0.85 B 1` 1 500 1 75 1.75 1 22 -_ 1 500 1 94 1.94 1.55 I-—A—f--A--1t7�70 2 500 2.25 2.25 2.45 ♦—Watling Pressure Rcxings are for reference way end based or Sas 4O pipe for the latest UA/Ut.C. and FM pressure ratings versus pipe schedule.please visit arolind corn or contact your local Ane l Represmtaeve. $Z /11 VIL www.anvilintl.com COUPLING ',,r ,,Zn1VIL 5PF/RNVL Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fittings are UL& ULC Listed& FM Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-12. Dimensions conform to ASME B 16.14 Threads are NPT per ANSI/ASME B 1.20.1. NOTICE:Ductile iron fittings have higher tensile strength than that of steel pipe.Therefore,over tightening con cause domoge to pipe threads while may cause leakage.Oudde iron fittings should be tightened three turns beyond hand tight,but no more than four turns/�� cols fM WM APPROVE° ro.Gs rgs,APP-'±.A aetah.mntl lmdah.s. COUPLING IRzniri « .x,...Aft , Nominal Size Max.Working Dimensions Approx. Pressure. A Wt.Each lea Act) PSf tV M.lemon.) tbs.IV , C--� 1 500 1.67 0.40 25 3450 42.42 1' 500 1.93 0.57 32 3450 4902 1 Yr 500 2.15 0.15 4! 3450 0 34 2 500 2.53 1.15 3450 64.26 7 C? A-Working Pressure%tinge ore for reference only and based on Sch,40 pipe For the truest UI.NtC. and FM pressure ratings serves pipe schedule,ploase visit amnlirdl.cam ce contact your local Anvil Representative. 'x'4111 4Yv!l! www.anvilintl.com REV d 5 11 18 CAP -1r ANV t «(C Fiaw Ductile Iron MATERIAL SPECIFICATIONS k= � Ductile iron threaded fittings ore UL& ULC Listed& FM Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-12. Dimensions conform to ASME B 16.14 Threads are NPT per ANSI/ASME B 1.20.1. NOTICE Ductile iron fittings have higher tensile strength than that of steel pipe.Therefore,over tightening can mute domoge to pipe threods which may coarse leakage.Ductile iron fittings should be tightened three turns beyond hand tight,but no mare that four turns. C®M um. rArrecNED ffotbos owftwagm war and Urnrfar. CAP .>Ra«..a..r.l.eaulnwaa...n« ,x 41.0.1 n kwr solos fMa+waeMo. Nominal Size Max.Working Dimensions Approx. PressoreA A WI.Each k.(Am) fkfbl Nt ttnral 1 500 1.16 0.32 25 3a',, 29.46 0,15 A 1Yi 500 1.28 0.43 3? 34rii l r 500 1.33 €0.60 40 34 ,. 33.7E 2 500 1.45 0.91 ♦-Working Pressure Ratings are far reference only and based an Soh 40 pipe For die bast UVUCC, and fM pressure ratings versus pupa schedule,please visit anvilinti can Of contact your local Anvil Representative www.anvilintl.com • • BUSHINGS (111r)iiNVIL: s /RNV ► j Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fittings are UL& ULC Listed & FM Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-12. Dimensions conform to ASME B16.14 Threads are NPT per ANSI/ASME B1.20.1. NOTICE:Duchle iron fittings have higher tensile strength than that of skid pipe.Therefore,over tightening can cause damage to pipe threads which may cause leakage.Ductile iron fittings should be tightened three tums beyond hand tight,but no more Chars four Karns/���.�� egli FN UM APPROVW For lstlY +Appo m:M40M ad LMOMIUA. BUSHINGS ,...r wrwebw re;warMrsm w. wt or oil Amor Ste. Nominal Size Max.Waking Dimensions Approx. Pressures A a h t Style WI.Each to,fru) PSI(km Le 0.0 hi ow h.(met) lbs.(kgf ''C 1 x'4 S00 US US 1.42 Outside 0.27 1=1 " J ;I }I Bis : , a; 6,35 '; �. t 1 x Y, 500� 0 75 0.25 142 Outside 0,17 4 A 635 1_=x 1 500 0.80 0.28 1.76 Outside 0.28 Inside Head 20 32 2 13 1' x 1 500 0.83 0.31 2.00 outside 0.45 7,13 s,'4 02t 1,,x 1 i 500 0.83 0.31 2.00 Outside 010 r C I } .`t. i 1_324 51 - 4 _ MI 111111111111111 B 2 x 1 500 0.88 0.41 1.95 inside 0.67 A 50 r 75 2235 ;0 4'4 4%<? 0,"te 2 x 1% 500 0.88 0,34 2.48 Outside 0.73 ._'_.w r32 2235 543E - Outside Head 2 x 1 h 500 0.88 0.34 2 48 Outside 0.61 50r40 2 ;?} 3,'t a-Waking Pressure Ratings ore for reference only and hosed on Sch dp pipe.For the fates+UL'UIC. and FM pressure ratings versus pipe schedule,please visit°m aintl tern at contact yo+;r local Arnil Representanvm. Z 41°41V11; www.anvilintl.com ' s REDUCING COUPLING !A!v!L (<(EPF/ANV Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fittings are Ul& ULC Listed & rE FM Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-12, Dimensions conform to ASME B16.3 Threads are NPT per ANSI/ASME 81.20.1. NOTICE:Ductile iron fittings have higher tensile strength than that of steel pipe.Therefore,over tightening eon cause damage to pipe threads which may cause leakage.Ductile iron fittings should be tightened three turns beyond hand tight,but no more than four trims Ca. 11111111 WOWED for itwgtrMP_+d+r Os and UneMsra REDUCING COUPLING veal«s atawritaniallGemN crortaci Awl* retina ltew tlomiocl Size Max.Working Dimensions Approx. UMW e. A WI.Each PSI re / I x h 500 1.69 0.39 A 25 x t5 3450 42,92 1 x3 500 1.69 0,53 3450 t?92 t-Wanting Pressure Ratings are far referenne only and based on Sch.40 pipe.Far the latest ULrUIc, and FM pseswre ratings versus pips scM dine,please visit o wil;nrl corn or contact you*iocol Anvil Represa<rtotiva. (13/ANVIL www,anviiintl.com SPF/FiNVIL° DUCTILE IRON THREADED FITTINGS z ANVIL FIG. 3388 Cored Plug 1 . C CS N. ../' - LISTED APPROVED / —"` For Listings/Approval Details and Limitations, visit our website at www.anvilinticom or ""r'4'-" � contact an Anvil®Sales Representative. FIGURE 3388 - CORED PLUG MATERIAL SPECIFICATIONS Nominal Size Maximum Dimension A Approx.Wt.Each Dimensions: ASME B 16.14 Working Pressure. In.(mm) PSI(kPa) In.(mm) Lbs.(kg) Material: ASTM A536 Grade 65-45-12 /2* 500 0.94 0.10 Finish: Black 15 3450 23.87 0.05 3/4 500 1.07 0.17 Threads: NPT per ASME B1.20.1 20 3450 27.17 0.08 1 500 1.25 0.28 Agency Approvals: All ductile iron threaded fittings are 25 3450 31-75 0.13 UL/ULC Listed and FM Approved. 1 i/, 500 1.36 0.44 32 34.54 70 A Pressure-Temperature Ratings in accordance with ASME B16.3 Class 150 11/2 500 1.45 0.62 NOTICE:Ductile iron fittings have higher tensile strength than that of steel pipe. 40 36.83 0.2E Therefore,over tightening can cause damage to pipe threads which may cause 2 500 1.56 0.91 leakage.Ductile iron fittings should be tightened approximately three turns beyond hand tight,but no more than four turns. 50 39.62 A—Working Pressure Ratings are for reference only and based on Sch.40 pipe.For the latest UL/ULC,and FM pressure ratings versus pipe schedule,please visit anvilintl.com or contact your local Anvil Representative. *Part supplied as Solid Plug. PROJECT INFORMATION APPROVAL STAMP Project: ❑Approved Address: 0 Approved as noted Contractor: 0 Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-5.16 BULL HEAD TEE MAIV.V11.4 5PF/RNVIL. -D) Cast Iron - Class 125 Fittings MATERIAL SPECIFICATIONS Cost iron threaded fittings ore UL& ULC listed - and FM Approved. Cast iron per ASTM A126. ,.. , . Dimensions conform to ANSI B16.4 Class 125. Threads are NPT per ANSI/ASME 81.20.1. _ . um APPROVE° Fry Lot-qv/44mM Oslais and UMW OW 0vl ois**mita IWONAWIIIMPAIDDIT et =Mg sti Amor sin annonown BULL HEAD TEE Nominal Size Max.working Dimensions Approx. Pressure. A B C Wt.Each b.Ow PS/(APa) ht.(jnm) itt(aor) ex Not) tbs.(1) 1xix114 300 1 67 1 67 138 1.52 1. 8--..-:-.---A-*I x 7.3.t3" 40 132 0.69 1x1x1'. 300 1 8 1,8 1.65 1.73 45,11 41 , 1 -dd. 300 1 88 1.8 1.82 2.05 -- ,,.,., 77 0.9'3 , - 1 1 ili.; 300 1.88 1.88 1.82 2.21 C .7.52 .7 Li ./.............. 1 4 x 1 v,x2 300 2.1 2.1 1.9 2.55 53.34 33 34 11/2x lAx2 300 2.16 2.1 2.02 2.80 40,02x40 ; ,. 54 364 '....' 51 308 1 21 114x114x2 300 2.16 2 16 2 02 3.28 e0x40;50 54 364 i‘ 1.4d 2x2x2i4 300 2.6 2 6 2 39 5.10 66 04 2.31 •-Wort.og Pressure Rohnos are for refererve only and bowl oe Sth 40 rhpe For the lorest UMW.,end FM pressure ming' versus pipe schedule,please war onvilind can or confect your loccd Artv 1 I Represeereew. ®141:9M114 www.anvilinticom Rei 4 5 12-6