Loading...
Plans w41.4 /01) Sw 1.1 t .'vj(w -'" CO (per 0 RECEIVED S`I SEP 07 2021 �I CITY OF TIGARD • BUILDING DIVISION ii 3 ^ E,s§-1 A � ; zo t. C.If?> 40.... t c.,\ i O AL Us./ I -692 0 ...• . r ,it 4 s ,, : "" ,a• r , fir ,-�- -4r- r..� . 1 . . :' - aA. Ilik I: y:aij . 414 �` .0I.,-' - +��tt +: f F w s _4 v: -ri..- s _ .T. 7 1 . \. `. - 4.. s. d r -.. ' ,t ` \� '`'' !n. r 'i�r~. . '(IV•1' RECEIVED SEP 0 7 20 RID I0713 G() �y 4641A1/ (6'Q 3 TIOZG s TABULAR DATA SHEEt10N LX SERIES SPLIT SYSTEM AIR CONDITIONERS 13.0 SEER - R-410A- 1 PHASE - 1.5 TO 5 NOMINAL TONS MO ELS: TC3B18 TO 60 PHYSICAL AND ELECTRICAL DATA • MODEL TC3B1822S TC 2423S I TC383022S I TC3B3623S J TC384223S I TC3B4821S TC3B6022S Unit Supply Voltage 208-230 V, 10,60 Hz Normal Voltage Rangel 187 to 252 Minimum CircuitAmpacity 12.9 11.4 18.4 19.8 21.1 28.5 29.1 Maximum Overcurrent Device(A)2 20 15 30 30 35 50 50 Minimum Overcurrent Device(A)3 15 15 20 20 25 30 30 Type4 Scroll Rotary Scroll Scroll Scroll Scroll Scroll Compressor Rated Load 9.7 8.4 14.1 14.7 15.9 21.8 22.2 Locked Rotor 46.0 53.0 73.0 75 112.3 117.0 127.9 Crankcase Heater No No No No No No No Factory External Discharge Muffler No No No No No No No HS Kit Required with TXV No n/a No No No No No HS Kit Part Number(S1-2SA067 )' 21806 n/a 10106 10106 10206 10106 10206 Fan Diameter(in.) - 18 18 18 18 22 22 22 Rated HP 1/8 1/8 1/8 1/4 1/4 1/4 1/4 Fan Motor Rated Load(A) 0.80 0.80 0.80 1.50 1.30 1.30 1.30 Nominal RPM 1075 1075 1075 1100 850 850 850 Nominal CFM 1950 1950 2150 2575 2925 3225 3350 Face Area(ft2) 9.78 9.78 11,07 12.37 13.83 13.83 17.37 Coil Rows Deep 1 1 1 1 1 1 1 Fins per Inch 23 23 23 23 23 23 23 Liquid Line Set OD(Field Installed) 3/8 3/B 3/8 3/8 3/8 3/8 3/8 Vapor Line Set OD(Field Installed)6 3/4 3/4 3/4 3/4 7/8 7/8 1-1/81 UnitCharge(lb-oz)7 2-13 3-7 3-10 3-12 4-6 4-8 5-1 Charge(oz/ft) 0.62 0.62 0.62 0.62 0.67 0.67 0.75 Operating Weight(lb) 125 130 140 165 175 165 190 1. Rated in accordance with AHRI Standard 110-2012,utilization range'A'. 2. Dual dement fuses or HACR circuit breaker.Maximum allowable overcurrent protection. 3. Dual dement fuses or HACR circuit breaker.Minimum recommended overcurrent protection, 4. Rotary compressor models are limited to en equivalent length of lineset 01100 ft with no exceptions. 5. Use S1-2SA067 series kit. Refer to the Hard Start Kit Accessory Installation Manual, 6. For applications with non-standard vapor line sizes,refer to the APPLICATIONS AND ACCESSORIES section In the Technical Guide. 7. The unit charge is correct for the outdoor unit,smallest matched indoor unit,and 15 ft of refrigerant tubing.For tubing lengths ether than 15 ft,add or subtract the amount of refrigerant,using the difference in actual linesel length(not the equivalent length)multiplied by the per foot value. DIMENSIONS =- - Dimensions Refrigerant Connection � Unit �! Model (1°) Service Valve Size 1 frt�*-I A 6 C Liquid Vapor ~`` - �, TC3B1822S 26 314 24 2A � + ":� TC3B2423$ 26 3/4 24 24 TC3B3022S 30 24 24 �= % =` TC3B3623S 33 1/4 24 24 3/8 3/4 A _`�.1` :i:�+�.'�'v, TC3B4223S 30 291/4 291/4 � ` ry may- TC3B4621S 30 291/4 291/4 7/8 �. vi == i 7C3660225 361/4 291/4 291/4 7/8$ � �.Y1Y�l-� ,' L 1 +j r+ t Adapter fitting must be field installed for the required 1 1/8-in.fine set. `��-�-, i +'; All dimensions are in Inches and are subject to change without notice. i i. F, .ice =��� Overall height is from the bottom of the base pan to the lop of the fan guard. �..t? g Overall length and width include screw heads. ewuvm Johnson Controls Ducted Systems 5717290-BTD-C-1220 20 - 7 SYSTEM CHARGE FOR VARIOUS MATCHED SYSTEMSf6;, Outdoor Unit TC3B18225 TC3B2423S TC3830225 TC3B3623S TC3B42238 TC3B4B21S TC386022S Required Orifice or TXV" 0.049/BHI 0.057/BH1 0.061/BA1 0.070/BA1 0.0751 BC1 0.077/BC1 0.0841 BD1 Indoor Unit3'4'5 Additional Charge(oz) AP18B 0 - - - _ _ _ AP24B 3 0 - - - - - AP306 - 7 2 - - - - AP366 - - - 0 - - - AP36C - - 2 2 - - - AP37C - - - 5 _ _ - AP42C - - - _ - - - AP48C - - - 5 2 0 - AP48D - _ . - - 2 0 AP60(C,D) - - - - 2 - AE18B 0 - - - - - - AE246 3 0 - - - - - AE3OB S 5 0 - - - - AE38(B,C) - 7 2 0 - - - AE42C - - - 5 2 - - AE48(C,D) - - - 5 2 0 - AE60C - - - - 9 2 0 AE60D - - - - 29 oz TXV ONLY 22 oz TXV ONLY 20 az TXV ONLY AVC18B 0 - - - - - - AVC24B 3 0 - - - - - AVC3OB 8 5 0 - - - - AVC36(B,C) - 7 2 0 - - - AVC42C - - - 5 2 - - AVC48(C,D) - - - 5 2 0 - AVC60C - - - - - 2 0 AVC6OD - - - - 29 oz TXV ONLY 22 oz TXV ONLY 20 oz TXV ONLY CF/CM/CU18(A,B) 0 - - - - - - CF/CMICU24(A,B) 3 0 - - - - - CF/CM/CU30(A,B,C) 8 5 0 - - - - CF/CM/CU36(A,B,C,D) 10 7 2 0 - - - CF/CM/CU42(B,C,D) - 11 2 2 0 - - CF/CMICU48(C,D) - - - 5 2 0 - CF/CM/CU60(C,D) - - - - 9 2 0 CF/CM64D - - - - 29 oz TXV ONLY 22 oz TXV ONLY 20 oz TXV ONLY Note:Some of the combinations shown in this table require Advanced Main Air Circulating Fan indoor product.For approved coil only matches,refer to the COOLING CAPACITY-Upflow,Downflow,and Horizontal Furnaces and Coils(Coil Only Ratings)table in the Technical Guide. 1. For applications requiring a TXV,use S1-1TVM^'series kit. 2. Approved orifice(s)shipped with outdoor unit. 3. Systems matched with furnaces or air handlers not equipped with blower-off delays may require 60-s time delay. 4. CF cots cannot be used in horizontal applications. 5. Charge adders shown above do not Indicate that coils are rated for every application.Reler to the performance data tables in the Technical Guide for actual perfor- mance for specified system matches.Obtain certified system ratings from pvtw.ahridirectory.oro CHARGING PROCEDURES 1. Check the factory unit charge Usted on the unit nameplate to verify the refrigerant charge for the outdoor unit,the smallest matched Indoor unit,and the 15 ft of inter- connecting lineset. 2. Verify the indoor metering device and additional charge required for the specific matched Indoor unit In the system using the SYSTEM CHARGE FOR VARIOUS MATCHED SYSTEMS table. 3. Add additional charge for the amount of interconnecting lineset tubing greater than 16 ft at the rate specified in the PHYSICAL AND ELECTRICAL DATA table. 4, For installations requiring additional charge,weigh in refrigerant for the specific matching indoor unit and actual llneset length. 5. After weighing in the charge adders for the matched indoor unit and lineset,verify the system operation against the temperatures and pressures in the charging chart for the outdoor unit,Locate the charging charts on the outdoor unit and also in the Service Data Application Guide on mar.simnlvoettinetheiobdones_om.Follow the subcool or superheat charging procedure in the Installation Manual according to the type of indoor metering device In the system,and allow 10 min after each charge adjustment for the system operation to stabilize.Record the charge adjustment made to match the Charging chart. 6. Permanently stamp the unit nameplate with the TOTAL SYSTEM CHARGE defined as follows:TOTAL SYSTEM CHARGE=base Charge(as shipped)+charge adder for matched indoor unit+charge adder for actual Ilneset length+charge adjustments to match the charging chart. Subject to change without notice.Published in U.S.A. 5717290-BTD-C-1220 Copyright®2020 by Johnson Controls.All rights reserved. Supersedes:5717290-BTD-B-0420 York International Corp. 5 York 6 9- 730 Norman, �OK 73069 . • lob g SL,Lf �tt( �j ��, (03 Goodman GMEC80 / GCEC80 Air Conditioning&Heating HEATING INPUT: 40,000-120,000BTU/H TWO-STAGE, MULTI-SPEED ECM GAS FURNACE 80%AFUE Contents Nomenclature 2 Product Specifications 3 I Goodman Dimensions 5 Accessories 6 G oddmo Airflow Data 7 Wiring Diagram 24 Standard Features Cabinet Features • Two-stage gas valve provides quiet, • Fully insulated,heavy-gauge steel cabinet economical heating with durable baked-enamel finish • Efficient and quiet multi-speed ECM circulator motor • Multi-position installation: • SureStart®Silicon Nitride igniter GMEC80:upflow,horizontal left or right designed for long igniter life GCECSO:downflow,horizontal left or right • Self-diagnostic control board • Removable bottom for side-or • Low constant fan speed circulates air bottom-return applications throughout the home • Convenient left or right connection • Quiet,two-speed induced draft blower for gas/electric service • California Low NOx emissions-compliant • Cabinet air leakage 5 2% models available • Coil and furnace fit flush • Can no longer be installed in California's for most installations South Coast Air Quality Management District (SCAQMD)on or after October 1,2019. • AHRI Certified;ETL listed ILIFETIME 1 O UNITI 10 PARTS NfiAT EXCXANOER LIMITED LIMITED A. LIMITta WARRANTY' YEAR WARRANT,' YEAR WARRANT! ���:1.......t. emBaM'MTM 1.1111coManrsnvN BI3Ei C 11• nrii.,5y41d rvmUA0000 000I. _ - cramra••1111. scan glUt Rmu •-�-�_ Intertek .aemor. .ae rw• •tomplein wauaniy[kWh ayarlalde from you; afal dttdrxr as at wwytgoodnt mmfi['Mtn to lemma lhr ldethne Hoot Exchange(tlrmrod Warranty(gwd Ief as long as you own your Iwtn✓).101Cn 1.0•1111 fIJ,4men1I nmX•d Warraolo and 10V¢ar Pans LlrMtcd wartanty online rmjitt4 W n must be (VmdeNrl wdtan(N)dns of rs,rallaUtln adlrM regntfalbn n not rayWccl Ui CaldWma w()miter SS-GMEC80/GCECSO www.goodmanmfg.com 2/21 YUWOMLR FIIO I0f l3 S'bk-} �° li' j Lp 72 SPECIFICATIONS 1 A IGMEC80 GMEC80 I GMEC80 I GMEC80 I GMEC80 GMEC80 1 GMEC80 I GMECBD I GMEC80 i GMEC80 I GMEC80 0403A• 0603A* 06038* 08036• 08048* 0804C• 0805C• 0805D• 1004C* 1005C* 1205D* HEATING CAPACITY High Fire Input(BTU/h)' 40,000 60.000 60,000 80,000 80,000 80,000 80,000 80000 100,000 100,000 120,000 High Fire Output(BTU/h)': Natural Gas 32.000 43,000 48,000 64,000 64,000 64,000 64,000 64,000 30,000 80,000 96,000 LP Gas 32,000 48,000 48,000 64,000 64,000 64,000 64,000 64,000 80,000 80,000 96,000 Low Fire Input(BTU/h)' 28,000 42,000 42,000 56,000 56.000 56,000 56,000 56,000 70,000 70,000 84,000 Low Fire Output(BTU/h)': Natural Gas 22,400 33.600 33,600 44,800 44,800 44,800 44,800 44,800 56,000 56,000 67,200 LP Gas 22,400 33,600 33,600 44,800 44,800 44,800 44.800 44,800 56,000 56,000 67,200 AFUE2 Bo 80 80 80 80 80 80 80 8D 80 80 Available AC@ 0.5'ESP 1.5.3.0 1.5-4.0 1.5-4.0 3.0-4.0 2.0-5.0 2.5-5.0 2.5-5.0 2.5-5.0 2.0:5.0 2.0.5.0 2.0-5.0 Temperature Rise Range(°F) 15-45/ 20-50/ 15.45/ 30-60/ 30-60/ 25-55/ 25-55/ 20-50/ 25-55/ 20-50/ 40-70/ 15-45 20-50 15-45 30-60 30-60 25.55 25-55 20-50 25-55 20-50 40-70 CIRCULATOR BLOWER Size (Dx W) 10"x 6" 10"x 6' 10'x8" 10"x8" 10'x 10' 10"x 10" 10"x1o" 11"x 10'' 10"x 10" 10"x 10' 11"x 10" Horsepower-RPM 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 1 1 Speed 5 5 5 5 5 5 5 5 5 5 5 Vent Diameter' 4" 4" 4" 4" 4' 4" 4' 4" 4" 4" 4" No,of Burners 3 3 3 4 4 4 4 4 5 5 6 ELECTRICAL DATA Min.Grout Ampacity' 8.7 3.7 8.7 8.7 12.45 12.45 15.32 15.32 12.45 15.32 15.32 Max Gvercurrent Device lamps)' 15 15 15 15 15 15 20 20 15 20 20 SHIP WEIGHT(1133) 105 10 107 118 121 129 129 129 124 124 124 ' Natural Gas BTU/h:for altitudes 0-4500'above see level.reduce input rating by 4%for each 1000'above 4500'altitude ' DOE AFUE based upon Isolated Combustion system IICSI ' Minimum Circuit Ampacity=(1.25 a Circulator Blower Amps).ID Blower amps,Wire size should be determined in accordance with National Electrical Codes.Extensive wire runs will require larger wire sizes. " Maximum Overcommit Protection Device refers to maximum recommended fuse or circuit breaker size.May use fuses or HACK-type circuit breakers of the same size as noted. NOTES • All furnaces are manufactured for use on 315 VAC 6014z.singk-phase electrical supply. • Gas Service Connection W'MT • Important:Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. • • • SS-GMEC80/GCEC80 wwwgoodmanmlg.com 3 9 G