Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
VED OFFICE. coPY ►+��` a + GREENHECK `-C �[ Printed Date: 09/09/2021 ( ] 4 ?RI Courtyard by Marriott - Tigard Building Value in Air. Mark: SF-1 Revised i Y OF TIGARD Model: CSP-A290 --15.5-- 31J;LDING D VISLON Model: CSP-A290 12.875 Inline Cabinet Fan + Standard Construction Features: 6.75 — AIR FLOW -Corrosion resistant galvanized steel scroll and housing-Sound absorbing insulation-Rectangular inlet and outlet duct collar-Outlet with integral spring loaded back draft damper-Double inlet forward curved wheel-Plug type 14 — 11.875 — disconnect-Adjustable mounting brackets-Field rotatable discharge — I—ey 1— — —--1 Selected Options &Accessories: Motor rated for continuous use 8 Motor with Thermal Overload MOUNTING Motor with CSA Approval BRACKET 11.25 L_ 10 Motor with 40 Degree C Ambient Temperature UL/cUL 507 Listed-Electric Fan Solid State Speed Control,6 Amp, Shipped Loose Adjustable easy installation mounting bracket Polypropylene Wheel Material Dimensional Quantity 1 Weight w/o Ace's(Ib) 23 Weight w/Ace's(Ib) 24 1.0 shaded • • Performance _ Requested Volume(CFM) 250 0.8 ?Op •• a • Actual Volume(CFM) 250 p Ra • Total External SP(in.wg) 0.25 0 • Fan RPM 1005 c 0.6 0° 'FLA(A) 0.83 y Elevation(ft) 108 N Airstream Temp.(F) 70 -.-_ d 0.4 -_ -.-. -... ........ ` a Air Density(Ib/ft3) 0.075 a : Bones 2.0 m 0.2 - • • System -._ - . - 0.0 \ 0 40 80 120 160 200 240 280 320 Motor Volume (CFM) Motor Mounted Yes 0 Operating point at Total External SP `*Input Watts(W) • 85 -Fan curve Voltage/Cycle/Phase 115/60/1 - - - -.System curve Enclosure l ODP Notes: All dimensions shown are in units of in. ----- 'FLA is approximate and will vary slightly with the motor. CIMCI3 Songs-calculated using AMCA 301 at 5 ft EIORIDWIDE OERTItIED ' Wattage is approximate and may vary between motors. RRTIRGf N., MUORMWE MR G:1M \2 ikeMorrison021 -Secured\Courtyard by Marriott-Tigard.gfcj CAPS 4.36.1184 Generated by:jbuntrock@johnsonair.com Page 1 of 1 This cut sheet was generated from Quick Delivery Online and Is for the product SKU referenced below.Cut sheets for accessories or ancillary products must be printed separately. ENJob Name: ftl SKU Mark: Quick Delivery 385031 Submitted By: Date:09/09/2021 Speed Control, 6 Amp, 120V, Wall Mounted ti Speed controls are used for manual adjustment of the fan's performance(for final system balancing) .is r or to control the fan's output in confined spaces, • such as conference or meeting rooms.The fan can be adjusted to 60%of design airflow with a speed control.This reduction in airflow and fan speed is also accompanied by a reduction in noise level. Note: For use on direct drive fans with single phase, PSC or shaded pole motors. Performance Characteristics This cut sheet was generated^y from Quick Delivery Online and is for the product SKU referenced below.Cut sheets for accessories or ancillary products must be printed separately. G N CK SKU Mark:Name. Quick Delivery VI KIT-SP/CSP Submitted By: Date:09/09/2021 Vibration Isolation Kit, Hanging, For Models SP/CSP Vibration isolation kit for suspended installation to minimize vibration, ensuring quiet operation. ilii Performance Characteristics Construction Features No Fan Curve Available. Document 451329 rl GREENHECK Hanging Vibration Isolator Kit for Models SP and CSP Building Value in Air. Assembly Instructions Please read these instructions carefully before attempting to assemble, install,operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! A 4. Install hanging t- support rods fit' 1/4.20_, using the hanging euppon following roa Uy others ► tt vibration isolator Ill centerline dimensions Assembly shown in table below. 1. Upon receiving kit, check for any damage and report it immediately to the shipper. Also, check to see that all parts are accounted for. (See reverse side for parts list). Isolator Centerline Dimensions 2. Determine desired location of mounting bracket on Unit Size A B SP/CSP fan; 9/64 inch diameter holes are factory B50-B200 41/2(114) 155 (397) prepunched for attaching mounting brackets. A50-A190 51/2(140) 15 (381) If different locations are desired, drilling will be A200-A390 63/4(171) 153/4(400) required. (See CAUTION). A410, A510,A710,A780 91/4(235) 193/4(502) 3. Insert neoprene grommets into large holes in A700 51/2(140) 253/a(645) mounting brackets. Thread one nut into each A900-A1050,A1410-A1550 91/4(235) 251/2(648) 1/4-20 threaded support rod (supplied by others) A1750, A2150 91/4(235) 363/4(933) followed by one flat washer and a shaft sleeve. A3600 91/4(235) 471/4(1200) Insert end of support rod and sleeve into grommet. All dimensions shown in inches(millimeters). Install another flat washer and nut on end of support rod, refer to Figure 1. Maintenance All fasteners should be checked for tightness each time maintenance checks are performed prior to ` r restarting unit.A proper maintenance program will a help these units deliver years of dependable service. v, DANGER 4) Always disconnect, lock and tag power source before installing or servicing. Failure to disconnect el,,... power source can result in fire, shock or serious �'/= injury. CAUTION Figure 1 When drilling be certain not to penetrate motor or 0 electrical components. rd Hanging Vibration Isolator Kit for SP/CSP .13 • Hanging Vibration Isolator Parts List 0 B ice 1/4-20 Threaded Rod rop:. - , V �(by others) /l0 Vim--- 1/4-20 Zinc Plated Nut � " 4 Zinc Plated Flat Washer c. Shaft Sleeve 7 F—Neoprene Grommet Qty Part No. Item Description e • 41110 4 370007 Neoprene Grommets 8 415386 1/4-20 Zinc Plated Nuts 8 415084 Zinc Plated Flat Washers .4 Zinc Plated Flat Washer 4 472045 3/8 x 1/4 Shaft Sleeves g .- 1/4-20 Zinc Plated Nut Our Commitment As a result of our commitment to continuous improvement, Greenheck reserves the right''to change specifica- tions without notice. Specific Greenheck,product warranties are located on greenheck.com within the product area tabs and in the Library under Warranties. Greenheck's Centrifugal Ceiling and Cabinet Exhaust Fans AMCA Publication 410-96,Safety Practices for Users and catalog provides additional information describing the Installers of Industrial and Commercial Fans, provides equipment, fan performance,available accessories,and additional safety information.This publication can be specification data. obtained from AMCA International, Inc. at www.amca.org. PI GREENHECK Building Value in Air. Phone:715.359.6171 •Fax:715.355.2399• Parts:800.355.5354•E-mail:gfcinfocgreenheck.com•Website:www.greenheck.com © 451329• Flanging Vibration Isolator Kit for SP/CSP,Rev.6,June 2021 Copyright 2021 ©Greenheck Fan Corporation 1. GREENHECK IDHE Duct Heater The IDHE series is the industry's first and only electric duct heater approved by UL for multiple mounting positions. This allows the control cabinet to be installed on either side of a horizontal duct or in any orientation on a vertical duct.The control cabinet is offset from the heating elements similar to traditional heaters. However, the IDHE affords the installer the flexibility to position the offset on the left or right as preferred. Standard Features • UL 1996 certified • 50/60 Hz compatibility • Zero clearance rating • Hinged control cabinet cover • Power and control terminal boards • Automatic reset thermal safety switch for primary over temperature protection • Heavy gauge G60 construction Individual maximum capacities are dependent on voltage/phase, control type, and heater dimensions. Absolute maximum capacity: 478.8 kW ff *The Greenheck model IDHE duct heater is universally configured to allow airflow in either direction in all mounting orientations. Construction Standard Optional Size Limitations Airflow Direction Universal W x H Minimum Size Maximum Size Contactor Magnetic Inches 8 x 8 120 x 144* Control Box mm 203 x 203 3048 x 3658 Offset Universal - *Consult factory for heights larger than 90 in. Control Voltage 24 Vac - (2286mm). Element Wire Standard 80/20 Heater Control Stage SCR,Vernier SCR* Options available: Heater Type Slip in Flange •Airflow switch (adjustable or fixed set point) 208/1,208/3, • Disconnect switch with door interlock Heater Voltage/ 240/1,240/3, • Dust tight box with gasketed door Phase 120/1 277/1,480/1, • Room thermostat 480/3 • Duct thermostat(available with SCR or Vernier SCR Material Galvanized Steel - control) • Pilot light Recess (in.) None 1,2,3 •Vapor barrier Control Unfused Fused, • 80/20 element wire Transformer None • De-rated coils .035' • Recess for internally insulated ducts Deration (kW) None 025 • Stainless steel hardware • Time delay relay- delay heater or delay stages *Vernier SCR is required in heaters greater than 48 amps to comply with NEC requirements. Installation instructions available at www.greenheck.com. IDHE: Air Flow Requirements Minimum Air Velocity: See charts below Maximum Inlet Air Temp: 110°F Maximum Heater KW: 30 KW per Square Foot of Duct Cross Section Inlet Air °F vs CFM /KW Minimum 180 160 140 j120 >= 100 Bo 60 LL V 40 20 0 - -50 —40 —30 —20 —10 0 10 20 30 40 50 GO 70 80 90 100 110 120 Inlet Air Temp ° F FPM Chart vs. KW/ Ft 2 —40°F 0'F —20•F 32°F 50°F 70°F 80°F 90°F 100°F 110°F 30- 24 26 24 22 • 20 N 18 LL 16 14 12 10 8 6 2 0 0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 FPM Minimum I M GREENHECK Copyright©2021 Greenheck Corporation IDHE Rev.7 May 2021 P.O.Box 410•SchoBeIC.WI 54476-0410•715.359.6171•greenhec0.corn GREENHECK Printed Date: 07/14/2021 / Job: Courtyard by Marriott - Tigard Building Value in Air. Mark: DH-1 Model: IDHE DHE Duct Heater APPLICATION & DES GN The IDHE se ies is the industry's first and only electric duct heate approved by UL for multiple mounting positions. This allows the control cabinet to be installed on eithe side of a ho izontal duct or in any orientation on a vertical duct. The control cabinet is offset from the heating elements similar to traditional heaters. However, the IDHE affords the installer the flexibility to position the offset on the left or right as preferred. Standard features include: -UL 1996 ce tiled -50/60 Hz compatibility -Zero clearance rating -Hinged control cabinet cover FLIP HEAT=R TO -Power and control terminal boa ds ACHIEVE RIGHT OFFSET -Automatic eset the mal safety switch for primary over temperature protection -Heavy gauge G60 construction R I . C PRODUCT DETAILS 1 SN Airflow Direction Universal Control Box Offset Universal I ac . Control Voltage 24 VAC 1- Deration None / ,-� Element Wire Standard -- ;)`< Heater Control Stage Heater Type Slip In !/ Z Heater Voltage/Phase 208/1 H Stainless Hardware No Power Fusing No Preference TYPE S W I V OPTIONS &ACCESSORIES sL' 'n . O-FSET LEFT Airflow Switch Non-Adjustable STANDARD Control Transformer Unfused Contactor Magnetic •This drawing shows a general damper configuration and is not Disconnect Switch Yes intended to depict the exact configuration of the heater. Thermostat None •All dimensions shown are in units of in. Fan Interlock No •Individual maximum capacities are dependent on voltage/phase, Vapor Barrier No control type and heater dimensions. Dust Tight Box No •Capacity:478.8 kW maximum Pilot Light None •Greenheck duct heaters are universally configured Time Delay Relay None to allow airflow in either direction in horizontal ducts. ID# TAG QTY WIDTH I HEIGHT CONFIGURATION Kilowatts. Stages: Amps: Power Fusing: 5 1 24.038 No 1-1 1 10.000 in. 10.000 in. , Dimension Q: Dimension Z: Dimension BD: Dimension U: 20.000 in. 11.938 in. 6.250 in. 6.000 in. Dimension N: Dimension R. Dimension T: 13.000 in. 1.000 in. 1.000 In. Minimum CFM* nlet Air Temp(F) -25 0 20 40 60 70 80 100 Row ID 1-1 78 93 112 137 176 202 237 349 'Minimum ai flow values are determined with uniform air volume across the face of heater coils.If air flow is not consistent across heater coils at minimum values,localized hotspots may occur and cause temperature overload to trip. Minimum FPM* nlet Air Temp(F) -25 0 20 40 60 70 80 100 Row ID 1-1 112 134 162 198 253 291 341 502 "Minimum air flow values are determined with uniform air flow across the face of heater coils. If air flow is not consistent across heater coils at minimum values,localized hotspots may occur and cause temperature overload to trip. G:1MikeMorrison12021 -Secured\Courtyard by Marriott-Tigard.gfcj CAPS 4.35.1025 Generated by:mmorrison@johnsonair.com Page 2 of 3 " z I' ,J � 7„ f v' 1 U1 CONTROL TERMINAL.. TO BRING ON HEAT STAGE(S) AR` WITH INTERNAL TRANSFORMER COMMON 1 0--o + CONNECT COMMON TO STAGE 1 1 (TYPICALLY WITH A THE.RMO TAP) sTAC- 1l :--0 1 I 1 1 WITHOUT INTERNAL TRANSFORMER 1 APPLY CONTROL VOL'IAGE TO COMMON / STAGE 1 1 1 1 1 \ L`_ - NA._. EA ER POWER BOARTERMINAL _ I \A/II R J J A H , J Q ,_. R J J 1 (CR ORTIONA_ I 1 LiSCONNEC- SWITCH) -- L 1 o� c ' 1 (L2 or N) o� 1 1 E- --J I 1 J ` JV L PO - � D ICEO P JCTJICAL_ HA -7 NOS MI NM - - - -.. l_. L_-_ CTR C; AL_ C. ONICJ - C; IC.) Nc r CP A JJC Jll` A ILL WI R AS CT, 2LVAC O 120 AC CON 0I._. ( i. , _ S This print and the confidential business if-for-motion which it GREENH�CK contain ore the prap -ty of Creenhec Fan Corporation ;f -afield Vbl It is 'oaned for con`id_ntlal a e by reupiFnt solely to per the busine 5 ntere is of Gr enheck e isr ub Act o return or recuest and with the mutual understanding that it Nit not be used in any manner detrimental :o -the interests at Gfeenheck. • GREENHECK Magnetic Contactor Magnetic contactors are standard in all duct heaters. They are used for primary or back-up control. UL approved for 250,000 cycle operation . moo` ', f Control Transformer Utilized when control voltage differs from line voltage. Primary over current protection. Class 1 units must have primary side protection by fusing. Class 2 units have internal protection and do not require additional fusing unless specified. � r Disconnect Switch Available unfused door interlocking disconnect switch (maximum 384 AMPS). 4�; Proposal TR�UVE (Valid for 30 days from Proposal date) PROPRIETARY AND CONFIDENTIAL PROPERTY OF Trane U.S. Inc. DISTRIBUTION TO OTHER THAN THE NAMED RECIPIENT IS PROHIBITED 2021 Trane Technologies All rights reserved Job Name: Date: September 8, 2021 Courtyard by Marriott Pool Renovation Proposal Number:Y2-89967-1 Tag Data -Trane - Mitsubishi Ductless Split(MXZ) Accy Item Tag(s) Qty Description Al No Tag 2 Trane - Mitsubishi Ductless Split (MXZ) Item: Al TAR-40MAAU, Wired, Wall-Mounted Programmable Controller MAC-3341F-E, M-net Interface for Controller Tag Data -Trane - Mitsubishi Ductless Split(MXZ) IDU Item Tag(s) Qty Description B1 FCU-1A, ECU-1 B 2 Trane- Mitsubishi Ductless Split (MXZ) Item: B1 NTXWST18A112AA, 1.5-Ton Wall-Mounted Indoor Unit Tag Data -Trane - Mitsubishi Ductless Split (MXZ) ODU Item Tag(s) Qty Description C1 HP-1 1 Trane- Mitsubishi Ductless Split (MXZ) Item: Cl NTXMMX36A142AA, 3-Ton Multi-Zone Heat Pump MAC-A454JP-E, Port Adaptor 3/8"x1/2" Tag Data -Trane - Mitsubishi Ductless Split (M Series) Item Tag(s) Qty Description D1 HP-2 1 Trane- Mitsubishi Ductless Split (M Ser D2 HP-3 1 Trane- Mitsubishi Ductless Split (M Ser Item: D1, D2 NTXSST12A112AB, 1-Ton Single Zone Heat Pump NTXWST12A112AA, 1-Ton Wall-Mounted Indoor Unit TAR-40MAAU, Wired, Wall-Mounted Programmable Controller MAC-3341F-E, M-net Interface for Controller MITSUBISHI ELECTRIC Nv-SERIES 800SUBMITTTALDDATA: NTXWS INDOOR UNIT FOR DT18A112AS1NE HEAT PUMP TEMS Job Name. Courtyard by Marriott System Reference: FCU-1A,FCU-1B Date 912/2021 Indoor Unit 'ireless Remote Controller NTX'JSSTlSA112A* FCU-1A, FCU-1B GENERAL FEATURES • Slim wall-mounted indoor units provide zone comfort control • The outdoor unit powers the indoor unit,and should a power outage occur,the system is automatically restarted when power returns • Multiple fan speed options'.Quiet,Low,Medium,High,Super-high,Auto • Multiple control options available: -Hand-held Remote Controller(provided with unit) -kumo cloud®Sinai device app for remote access •Third-party interface options -Wred or wireless controllers • Hot-Start Technology'.no cold air rush at equipment startup or when restarting after Defrost Cycle • Quiet operation • Smart Set:recalls a preferred preset temperature setting at the touch of a button Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC,All rights reserved. SPECIFICATIONS: NTXWST18A112A* Cooling Capeotyt•a _... _.. BTU/H 18,000 • •Heating Capacity,.' BTU/H 21,600 Voltage,Phase.Frequency 20B/230V,1 phase,60Hz I Guaranteed Voltage Range V AC 187-253 Electrical Voltage:Indoor-Outdoor,S1-S2 V AC 208 f 230 • Voltage:Indoor-Outdoor,S2-S3 V DC 24 Short-circuit Current Rating(SCCR) 5 MCA A 1 Blower Motor Full Load Amperage A 0.87 Blower Motor Output W 30 Airflow Rate at Cooling,Dry CFM 646-522-417 332 258 • • _.. Airflow Rate at Cooling,Wet CFM 581-470-375-299-232 Airflow Rate at Heating,Dry CFM 646-565-469-385-297 Sound Pressure Level(Cooling) dB(A) 49-44-38-33-28 Sound Pressure Level(Heating) dB(A) 48-43-38-33-28 Oran Pipe Size In.(ran) 5/8(15.88) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.OY 9.2/0.2 W.In.(mrn) 36-5/16(923) • Unit Dimensions D.In.(mm) 9-13/16(250) j H.In.(mm) • 12(305) • W:In.(mm) 39(990) Package Dimensions D In.(min) 13(330) H'.In.(mm) 15(380) Unit Weight _.... Lbs.(kg) 28(13) Package Weight Lbs.(kg) 33(15) Refrigerant Type _ , R410A Gas Pipe Size 0.0.(Flared) In.(mm) 1/2(12.7) Piping Liquid Pipe Size O.D.(Flared) In.(mm) 1/4(6.35) Notes: 'Cooling(Indoor/l Outdoor) °F 80 DB 67 WB//95 DB,75 VVB Nominal Conditions -- 'Heating at 47°E(Indoor/1 Outdoor) °F 70 DB,60 WH/147 DB,43 W13 'Capacity vanes based on the number of indoor units operating and the model of the Multi-zone Outdoor Unit.For reference to connected capacity charts,please refer Multi-zone Outdoor Unit • Operational Performance. • Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. ACCESSORIES: NTXWST18A112A* TI.-atb rqy Enzyme Filter MAC-408FT-E kunn ::,mn M RedLINKTM Wireless Controller r MHK2 Deluxe MA Remote Conlrotlerl TAR-00MAAU Simple MA Controller' TAC-YT53CRAU-J Touch MA Controller's--- ---- --- ---- •c TAR-CTOIMAU-SB - - Wireless Temperature and Humidity Sensor r PAC-USW1S003-TH-1 System Control Interface' --- - - _ '.c MAC-3341E-E Wireless Interface 2 ---- ---- ---- -_-- _-- ---- --- nPAC-USWHS002-VVF-2 -_- -_ Thermostat Interface --- _--' '.n PAC-US444CN-1 kumo stations __--. -... .... -... _.. u TAC-WHS01 HC-E USNAP Interface -_- ---- _-- _--- E _-- PAC-WHSa1UP- IT Extender _...._ _...- __. _.... __._ _. . ......... _.. u PAC-WHS011E-E BACnete'and MODBUSe'Interface PAC-UKPRC001-CN-1 Lockdown bracket for Hand-held Remote Controllers u RCMKPiCB • Blue Diamond Sensor Extension Cable-15 FL 'r C13 103 '. Blue Diamond Alarm Extension Cable-6.5 Ft. oC13-192 Blue Diamond MultiTank—wllection tank for use with multiple pumps c C21.014 Blue Diamond Rubber Foot Pads c F10-010 Mini Condensate Pump-230 volt application '.05130.230 MegaSlue Advanced Blue Diamond Condensate Pump w/Reservoir&Sensor o X87-835-110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(110V)up to 48,000 BTU/H[recommended] n X87-711-110V Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(208/230V)[recommended] �'o X87-721-208/230V MicroBlue Blue Diamond Mini Condensate Pump(110/206l230V)up to 18,000 BTU/H a X85-003 Fascia Kit for MicroBlue Pump—mourns the MicroBlue and sensor directly beneath the indoor unit n T18-016 Drain Pan Level Sensor -_-- -- - -- --- --_-- • -_ u SS61oE (30A/600VIUL)[fits 2"X 4"utility box]-Black o TAZ-MS303 (30A/600V/UL)[fits 2"X 4"utility box]-White _-- o TAZ-M S303W t Requires MAC-3341E-E 2 Allows indoor units to connect to an MA Controller • Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. DIMENSIONS: NTXWSTI8A112A* Unit: inch 7116x13/16 Installation plate Oblong hole Indoor unit 1 x7/16 Oblong hole 3.11116 3GSi1fi _ 3-11/16 8-7/8 8-718 ' 35-13116 114 f r l_� 9-13/16 8-11/16 8-1/16 _ 3116 -I 2-5/16 15.718 15-3/16 3 'I ,I Airin Wall hole 03 N _ _ V Installation plate "I ■. a' 2-112 2-1/16 27-15/16 6-5116 Pi In N m oo 7 g \ / Drain hose 2-5/16I II 3/4 ` 1Tm=� 2-9116 `r � � 4-1/2 ciii IT ICI 1��1 Air out 5-3/4 ��� N I I 2.9/16 2-9/16 CO ' 3-11116 o, Insulation 02 0.0 N A A o. Liquid line 05/16 15-3/8 (Flared connection 01/4) 6- Gas line 015/32 13-3/8(Flared connection 01/2) Drain hose Insulation 01-1/8 Connected part 05/8 0.D 't' FORM#NTXWST1eA112A'FOR MULTI•ZONE HEAT PUMP SYSTEMS-202008 .N4zA^.=ve Interfek Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. � I mir 10)01c- Job Name: Courtyard by Marriott System Reference: HP-1 Date:9/2/2021 HP-1 ,1i10,l1i1llllllllllii1i1l. 1iIIIIIIIIIIII111111IIIIIIIIIIII IIII 1111111111111111111111111111IIIIIIN 1111113 111111111111111111111111111111111111111 114 • FEATURES • Variable speed INVERTER-driven compressor • Optional base pan heater • Quiet outdoor unit operation as low as 56 dB(A) • High pressure protection • Compressor thermal protection • Compressor overcurrent detection • Fan motor overheating/voltage protection Specifications are subject to change without notice. C 2021 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. r � SPECIFIGATIONS. (For data on specific Indoor units,see the MXZ-C Technical and Service Manual.) Rated Capacity Btum 35,400/34,400 Cooling' Capacity Range Btum 9,500-36,400/9,500-34,400 (Non-ducted/Ducted) Rated Total Input W 3,780/3,940 Rated Capacity Btum 36,000/34.400 Heating at 47°F' Capacity Range Btum 15,500-43.000/15,500-41,400 (Nan-ducted/Ducted) Rated Total Input W 3,020/3,100 Heating at 17°F• Rated Capaaty Btu/h 22,200/20,300 (Non-ducted/Ducted) Rated Total Input W 3,340/3,450 Connectable Capacity Btufn 12,000-,42,000 -. Power Supply Voltage.Phase,Hertz 208/230V,1-Phase,60 Hz Electrical Requirements Recommended Fuse/Breaker Size A 25 MCA A __. 22.1 Indoor-Outdoor 51-52 V AC 208/230 Voltage Indoor-Outdoor S2-S3 V DC±24 Compressor INVERTER-driven Scroll Hermetic Fan Motor(ECM) - FLA 2.43 Cooling dB(A) 54 Sound Pressure Level - Heating dB(A) 56 In 31-11/32 x 37-13/32 x 13 External Dimensions(H x Wx D) MIT (796 x.950 x 330) Net Weight Lbs 1 kg 139(63) External Finish' Munsell 3.0Y 7.0/1.1 Liquid(High Pressure) In/mm 1/4(12.7) Refrigerant Pipe Size O.D. . -- Gas(Low Pressure) In/tom A:1/2(6.35) B,C,D.3/8(952)230(70) Max.Refrigerant Line Length Ft/m 230(70) Max.Piping Length for Each Indoor Unit Ft/m 82(25) Max.Refrigerant Pipe'Height If IDU is Above ODU Ft/m 49(15) Difference If IDU is Below.ODU Ft/m 49(15) Connection Method Flared/Flared ' Refrigerant R410A *Rating Conditions per AHRI Standard. Cooling I Indoor.80°F(27°C)DB/67°F(19°C)W8 Heating at 47°F I Indoor',70°F(21°C)DB Heating at 17°F 1 Indoor:70°F(21°C)DB Cooling 1 Outdoor 95°F(35°C)DB/75°F(24°C)WB Healing at 47°F I Outdoor:47°F(8°C)DB/43°F(6°C)VvB Heating at 17°F I Outdoor 17°F(-8°C)DB/15°F(-9°C)WB OPERATING RANGE, ENERGY EFFICIENCIES: Outdoor Indoor Unit Type SEER EER HSPF COP(t 47°F COP @ 17°F Cooling 14 to 115'F(-10 to 46°C)DB Non-ducted 19.2 9.4 11 0 3.50 2.67 (09+09+09+09) Heating 5 to 65°F(-15 to 18°C)WB Ducted and 176 9.05 10.4 3.38 2.61 Non-ducted Ducted 16.0 8.7 9.8 3.25 2.54 i (09+09+09+09) NOTES: For actual capably performance based on indoor unit type and number of indoor units connected,please refer to MXZ Operational Performance. Although the maximum connectable capacity can exceed rated,the outdoor unit cannot provide more than 100%of the rated capacity.Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Specifications are subject to change without notice. m 2021 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. Refrigeration Ball Valve-1/2' ❑ BV12FFSI2 Refrigeration Ball Valve-1/4 ❑ BV14FFSI2 Ball Valve - --- Retngerahon Ball Valve-3/8" ❑ BV38FFSI2 Refngeratton Ball Valve-5/8'. ❑ BV58FFSI2 Centralized Drain Pan Drain Pan ❑ PAC-SH97DP-E Drain Socket Orals Socket ❑ PAC-5G60DS-E Hail Guards Had Guard ❑ HG-A9 Condensing Unit Mounting Pad 24"x 42"x 3" ❑ ULTRILITE2 Mounting Pad Outdoor Unit 3-1/4 inch Mounting Base(Pair)-Plastic ❑ DSD-400P Optional Defrost Heater Optional Defrost Heater D PAC-645BH-E Adaptor.1l2'x 3/8" ❑ MAC-A455JP-E Adaptor 1/2"x 5/8" 0 MAC-A456JP-E Port Adapter Adaptor 3/8'x 1/2 C MAC-A454JP-E Adaptor'.3/8'x 5/8" C..PAC-SG76RJ-E 24'Dual Fan Stand _.. C OSMS2402M Condenser Wall Bracket ❑ CISVWB2000M-1 Stand _. Condenser Wall Bracket Stainless Steel Finish D CS WBSS Outdoor Unit Stand-12'High ❑ OSMS1202M Specifications are subject to change without notice. ©2021 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. m " Unit: inch 6-7/8' 23-S/8' 6-7/8' " P _1?/16' - e L-19 32' 2- Sna•ed NOlclle• HO -1.3Z' r el IFOundO'lOn Bolt M101 m II .. I ' mlL 4 ry l-l-ems_ --a=_ ��- .� see e.mrnke0 , ._-. - - f- 6-11-5/16'Orme •Hole u If7�i�� oIsmeree r' 1 9-9 b 3/32'1. 13/32' 1-1/32' 2-.2/8'knockaul ode 2-115/32'x1-13/32'l Oval Mole 1 11/2 I 1Co'. r e wire hole/ novae -, '/ 32 1 32. L ---. Oun M/O iDn O 0 1 5/8 II 3 2/8 p Idled Idle 31/32' - -13' 19/32' 11 (Co ecl g wire Iolel I ml 11 1 1 14 ato 1 - ■f 'I J®f 1 q s I�ti111 i- •.__J 2-3,L' E=CCIi f C p dxe 1.0 o® IIj � Jljj, I ;10.1 cssI '' d ea35F/.FE f [44 f 1® �'"'" ..a I-+`�l I�� _GPS 3 BiP953FLPFE mB! i 4i Gn5L'o f Li-P Sntr2'tmto 7,V.:PRE=11._ I� 1 1 bra — ---° ,. 5 I 1-11,32' 1.FREE SPACE Ik E r. 3-15/16' or more l} as f1� PI 3-15/16' or more 13-25/32 or more 2.SERVICE SPACE ,r 4I1 L iI Conduit plates it, conduit Conduit connector r '� Iv •ri I'1Iw._ __ 3-15/16' or MOPS SEFv4E SPACE Lock nut 13-25/32' or mare 13-25/32' or acre AM WOWED' e.mw *-=a•-� FT i� .l c us I FORM#T SUBMITTAL_NTXMMX36A142AA_en-202107 ?" - Intertek Specifications are subject to change without notice. ®2021 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. MITSUBISHI ELECTRIC Nv-SERIES SUBMITTAL DATA: NTXWST12A112A* & NTXSST12A112A* 12,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM Job Name: Courtyard by Marriott System Reference:FCU-2, HP-2 Date:9/2/2021 Indoor Unit: Outdoor Unit: Wireless Remote NTXWST12A112A` ❑NTXSST12A112AA Controller I NTXSST12A112AB FCU-2 HP-2, HP-3 FCU-3 II I [ I1 I < GENERAL FEATURES • Slim wall-mounted indoor units provide zone comfort control • The outdoor unit powers the indoor unit,and should a power outage occur,the system is automatically restarted when power returns • INVERTER-driven compressor and LEV provide high efficiency and comfort while using only the energy needed to maintain maximum performance • Multiple fan speed options:Quiet,Low, Medium, High,Super-high,Auto • Multiple control options available: -Hand-held Remote Controller(provided with unit) -kumo cloud®smart device app for remote access -Third-party interface options -Wired or wireless controllers • Quiet operation • Smart Set:recalls a preferred preset temperature setting at the touch of a button • Blue Fin anti-corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. SPECIFICATIONS: NTXWST12A112A* & NTXSST12A112A* Maximum Capacity BTU/H 13,600 Rated Capacity BTU/H 12,000 Minimum Capacity BTU/H 1,500 Coolingi Maximum Power Input W 1,300 Rated Power Input W 920 Moisture Removal Pints/h 2.5 Sensible Heat Factor 0.77 Power Factor % 95/95 Maximum Capacity BTU/H 18,100 Rated Capacity BTU/H 14,400 Minimum Capacity BTU/H 2,000 Heating at 47°F2 Maximum Power Input W 1 620 Rated Power Input W 1:100 Power Factor % 96/96 Maximum Capacity BTU/H 12,000 Rated Capacity BTU/H 9,200 Heating at 17°F3 Maximum Power Input W 1,240 Rated Power Input W 870 Maximum Capacity BTU/H 9,790 Heating at 5°F4 Maximum Power Input W 1,020 Heating at-4°FS Maximum Capacity BTU/H 7,920 SEER 23.1 EER1 13.0 HSPF(IV) 12.5 Efficiency COP at 47°F2 3.84 COP at 17°F in Maximum Capacity3 2.84 COP at 5°F in Maximum Capacity4 2.81 ENERGY STAR®certified units(ENERGY STAR products are third-party YES certified by an EPA-recognized Certification Body.) Voltage, Phase, Frequency 208/230V, 1 phase,60Hz Guaranteed Voltage Range VAC 187-253 Voltage: Indoor-Outdoor, S1-S2 VAC 208/230 Electrical Voltage: Indoor-Outdoor, S2-S3 V DC 24 Short-circuit Current Rating(SCCR) kA 5 Recommended Fuse/Breaker Size(Outdoor) A 15 Recommended Wire Size(Indoor-Outdoor) AWG 14 MCA A 1 MOCP A 15 Blower Motor Full Load Amperage A 0.76 Blower Motor Output W 30 Airflow Rate at Cooling, Dry CFM 399-321-237-170-145 Indoor Unit Airflow Rate at Cooling,Wet CFM 364-286-201-134-109 Airflow Rate at Heating, Dry CFM 406-321-237-170-145 Sound Pressure Level(Cooling) dB(A) 45-37-30-22-19 Sound Pressure Level(Heating) dB(A) 43-37-30-22-19 Drain Pipe Size In. (mm) 5/8(15.88) Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. . . SPECIFICATIONS: NTXINST12A112A* & NTXSST12A112A* Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.0Y 9.2/0.2 W: In.(mm) 31-7/16(798) Unit Dimensions D: In. (mm) 9-1/8(232) H: In. (mm) 11-5/8(295) W: In. (mm) 33-1/2(850) Package Dimensions D: In. (mm) 12(300) H: In. (mm) 14(350) Unit Weight Lbs. (kg) 22(10) Package Weight Lbs. (kg) 26(11.5) Indoor Unit Operating Cooling Intake Air Temp(Maximum/Minimum)* °F 90 DB,73 WB I 67 DB,57 WB Temperature Range Heating Intake Air Temp(Maximum/Minimum) °F 80 DB/70 DB MCA A 9 MOCP A 15 Fan Motor Full Load Amperage A 0.5 , Fan Motor Output W 55 Airflow Rate CFM 1,229/1,172 Refrigerant Control LEV Defrost Method Reverse cycle Heat Exchanger Type Plate fin coil Sound Pressure Level,Cooling1 dB(A) 49 Sound Pressure Level, Heating2 dB(A) 51 Compressor Type , , DC INVERTER-driven Compressor Model SNB092FQAMT Outdoor Unit Compressor Rated Load Amps A 6.6 Compressor Locked Rotor Amps A 8.2 Compressor Oil Type//Charge oz. FV505//11.8 External Finish Color Munsell 3Y 7.8/1/1 Base Pan Heater Optional VV: In.(mm) 31-1/3(800) Unit Dimensions , D: In. (mm) 11-1/5(285) H: In. (mm) 21-5/9(550) W: In. (mm) 37(940) Package Dimensions D: In.(mm) 14-15/16(380) H: In. (mm) 24-13/16(630) • Unit Weight Lbs. (kg) 81 (37) • Package Weight Lbs. (kg) 89(40) Cooling Air Temp(Maximum/Minimum)* , °F 115/14 Outdoor Unit Cooling Thermal Lock-out/Re-start Temperatures** ; °F -1 /3 Operating Temperature Range Heating Air Temp(Maximum/Minimum) , °F 75/-4 Heating Thermal Lock-out/Re-start Temperatures** ' °F -9/-4 Type R410A Refrigerant Charge Lbs,oz 2, 9 Gas Pipe Size O.D. (Flared) In. (mm) 3/8(9.52) Piping Liquid Pipe Size O.D. (Flared) In. (mm) ' 1/4(6.35) Maximum Piping Length Ft. (m) 65(20) Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. 1 I SPECIFICATIONS: NTXWST12A112A* & NTXSST12A112A* Maximum Height Difference Ft. (m) 40(12) Maximum Number of Bends 10 Notes AHRI Rated 1Cooling (Indoor!/Outdoor) °F 80 DB,67 WB//95 DB, 75 WB Conditions(Rated 2Heating at 47°F(Indoor//Outdoor) °F 70 DB,60 WB//47 DB,43 WB data is determined at a fixed compressor 3Heating at 17°F(Indoor//Outdoor) °F 70 DB,60 W B//17 DB, 15 WB speed) 4Heating at 5°F(Indoor//Outdoor) °F 70 DB,60 WB//5 DB,4 WB Conditions 5Heating at-4°F(Indoor//Outdoor) °F 70 DB,60 WB//-4 DB,-5 WB *Applications should be restricted to comfort cooling only;equipment cooling applications are not recommended for low ambient temperature conditions. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. ACCESSORIES: NTXWST12A112A* Anti-allergy Enzyme Filter MAC-408FT-E kumo touch RedLINK-fm Wireless Controller ❑MHK2 Deluxe MA Remote Controller TAR-40MAAU Simple MA Controllers TAC-YT53CRAU-J Touch MA Controllers ❑TAR-CTO1 MAU-SB Wired Remote Sensor ❑M21-EAA-307 Wireless Temperature and Humidity Sensor ❑PAC-USWHS003-TH-1 System Control Interface2 MAC-3341F-E Wireless Interface 2 :: PAC-USWHS002-WF-2 Thermostat Interface ❑PAC-US444CN-1 kumo station® o TAC-WHS01 HC-E USNAP Interface ❑PAC-VVHSO1UP-E IT Extender ❑PAC-WHS011E-E BACnet®and MODBUS®Interface ❑PAC-UKPRC001-CN-1 Lockdown Bracket for Hand-held Remote Controllers ❑RCMKP1CB Blue Diamond Sensor Extension Cable-15 Ft. ❑C13-103 Blue Diamond Alarm Extension Cable-6.5 Ft. a C13-192 Blue Diamond MultiTank—collection tank for use with multiple pumps ❑C21-014 Blue Diamond Rubber Foot Pads ❑F10-010 Mini Condensate Pump-230 volt application ❑S130-230 MegaBlue Advanced Blue Diamond Condensate Pump w/Reservoir&Sensor ❑X87-835- 110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(110V)up to 48,000 BTU/ ❑X87-711 -110V H[recommended] Advanced Blue Diamond Mini Condensate Pump w/Reservoir&Sensor(208/230V) [recommended] a X87-721 -208/230V MicroBlue Blue Diamond Mini Condensate Pump(110/208/230V)up to 18,000 BTU/H a X85-003 Fascia Kit for MicroBlue Pump—mounts the MicroBlue and sensor directly beneath the indoor unit a T18-016 Drain Pan Level Sensor E SS610E (30A/600V/UL)[fits 2"X 4"utility box]-Black c TAZ-MS303 (30A/600V/UL)[fits 2"X 4"utility box]-White TAZ-MS303W s Requires MAC-3341F-E 2Allows indoor units to connect to an MA Controller Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. DIMENSIONS: NTXWST12A112A* Unit: inch 7/16x1 Oblonq hole 7/16x13/16 Oblong hole Installation plate 3-1/81 _ 8-718 I 8-118 3-1/6 p, A A 31-7/16 A __ 30-15/16___. J_I_I4 o m _ — - - 60 m 6-II8. 6-II8 �T , - 2-3/8 13-5/16 13-9/16 - 2-I18 9-1/8 3!16 Indoor unit Ai in all hole t3 Milli -"- " 47;, late Il)55t0 24 I z Pi In 1 I-5/8 1-314 1-15/16 24-3/8 5-1/8 _ — r ,.� 4-3/16,„- - Drain hose IRE 2-5/16I I 3/4 ■ Air out — I ^I — M Insulation m1-3/8 O.D ,�I� i l I II • n Liquid line m114 19-11/16(Flared connection 01/4) "a Gas line m3/8 16-15/16 2-3/16 1-15/16 (Flared connection,e3/8(06109112 KBTUIH),m1/2(15 KBTU/H) I 1-3/16 Drain hose Insulation m1-1/8 O.D Connected part 05/80.D • Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. DIMENSIONS: NTXSST12A112A* Unit: inch REQUIRED SPACE *1 4 in. or more when front and sides of the unit are clear Al i;l1!1iiIIIIIIIIVIIIIIIII Hill IIIIIIIIIIIIIIII�IIIIIIIIIIIIIII Illllidlllllllllllllllllll r. I 15-3/4L. �I ', v Aw ':!Iliillll!Illguiiilllllll ��� n Drain hole 01-21/32(09/12115 Bluth) ° �. .;;till 1 10 Y, hey < ` (n° a ' 40 l> I .�o [�I a\� Ore 2 N 2.2` — �e *2 When any 2 sides of left, right ig 1-9/16 go and rear of the unit are clear Air out 2-holes 3/8X13/16 Service lane! 7/8 11/16 1 .. y , =.ri I ._J. Liquid refrigerant pipe joint (� 1� �; r Refrigerant pipe(flared)0 1/4 co f �'- = m ' - I Gas refrigerant pipe joint N L\ I ��\ � N f Refrigerant pipe(flared)03/8(09/12 KBTU/H) m n m I sr� ll m 1/2(15 KBTUIH) r jl., It �� d rim.�: I`imiiil t t it W 11-29/3 ._ 5-11/32 -15/14. 19-11/16 6-23/32 Bolt pitch for installation 31-1/2 2-3/4 SUSUS FORM#NTXWST12A112A*/NTXSST1 2A11 2A*-202003 Intertek Specifications are subject to change without notice. ©2020 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. h= eN t(liu w 1 f13 x l i 1'hSa_,: "II4ti � y iii� Mau: + y Lys y. - t N ae ..S gg t d`a r a va i - �� Job Name: Courtyard by Marriott Pool Renovation System Reference: Wired, Wall-Mounted Programmable Controller Date: 9/2/2021 0 NTITSUBIShk 8 MtTStJBISH I ELECTRIC Wit ELECTRIC 2:3G Fri r;. 72.0`F 72:0 F a Pura 78.0°F 7$.O*F ' 70.0.E sr. 7 °� x� Mode - Temp. + ® Mode — Temp. + Fan MENU ' RERAN SELECT MENU RETURPI SEi E O #IOtn OFF w010 OFF FULL VIEW BASIC VIEW OPERATION/DISPLAY • ON/OFF • Clock - Switches between ON and OFF - Date(year/month/day)and time(hour/minute)can be set. • Operation mode switching - The set time as well as the day of the week will be displayed on the Main display. - Switches between Cool/Dry/Fan/Auto/Setback/Heat. - It is also possible for the time to not display on the main display. - The clock can be displayed in 12-hour format(AM/PM before or after the time)and 24-hour • Hold format Switches between enable and disable the Hold function • - If the Hold function is enable,the following functions will be prohibited. Daylight saving time - ON/OFF timer/Schedule(Weekly timer)/Auto return/Auto-OFF timer - The daylighstart/et saving time funcion will be activated based on the setting contents. • Temperature setting • - Changes the set temperature. Room temp,display - The room temperature display can be enabled or disabled. - Set temperature range vanes depending on the indoor unit model. • Fan speed setting • Error information - Changes fan speed. - When an error occurs,an error code and the unit address appear Available fan speeds vary depending on the model. - The air-conditioning unit model,serial number,and contact number can be set to appear when an error occurs.(The above information needs to be entered in advance.) • Air flow director setting • Filter information Changes airflow direction. - A filter sign will appear when it is time to clean the filter. - Available airflow directions vary depending on the model. • Remote controller information • Louver setting - The version of the remote controller can be checked. - Switches between louver ON/OFF. • Ventilation equipment control •1 This function is active only for the units that support the function. - Interlocked setting and interlocked operation setting with City Multi Lossnay units can be •2 The clock is accurate within 45 seconds per month(at the temperature of 77'F[25°C]). performed. - The Stop/Low/High settings of the ventilation equipment can be controlled. The clock is backed up for 3 days. • Main display mode setting - The Main display can be displayed in two different modes:"Full"and"Basic." • BBW inversion - The colors of the display can be inverted,turning white background to black and black characters to white. i5T ;ter.. -` dd ___ SCHEDULE AND TIMER SETTING MISCELLANEOUS ITEMS • Timer • Language Selection • ON/OFF timer - Select the display language from the following 3 languages. Turns ON and OFF daily at a set time. . English,French,Spanish - Time can be set in 5-minute increments. • Brightness Contrast It is also possible to set the ON time only or the OFF time only. - The brightness of the LCD can be adjusted.The contrast of the LCD can be adjusted. - Auto-OFF timer • - Turns off the unit after a certain period of operation. Manual Vane Angle" - Operation lime can be set to a value from 30 to 240 minutes in 10-minute increments. - Fixes the vane position for each air outlet. • • Weekly timer Service" Weekly ON/OFF times and set temperatures can be set. - Contains Test run,Function setting,Request code,and Error history. - Tme can be set in 5-minute increments.Up to schedule patterns can be set per day of • 3D i-see Sensor the week. - Settings for 3D i-see Sensor can be made. - Not valid when the ON/OFF timer is set. ENERGY SAVING OPTION RESTRICTION SETTINGS • No occupancy energy save • Allows/disallows local operation - Requires 30 i-see sensor on applicable indoor units - The following operation can be prohibited by applying certain settings on the centralized controller.ON/OFF operation mode,set temperature,filter sign reset,air direction,fan ' Room Occupancy energy save speed and timer - Requires 3D i-see sensor on applicable indoor units - Vvhile an operation is prohibited,the operation icon lights up(only on the Main display in the • No occupancy Auto-OFF "Full"mode). - Requires 3D i-see sensor on applicable indoor units • Operation lock • Setback Mode - The following operations can be prohibited Sensing Location,ON/OFF Mode.Set temp., Menu,Fan,Louver,Vane,or Hold '1 This function is active only for the units that support the function. • Temperature range restriction '2 The clock is accurate within 45 seconds per month(at the temperature of 77°F[25°C)). - The room temperature range for each operation mode can be restricted. The clock is backed up for 3 days_ • Auto return - The units operate at the preset temperature after a designated pedal. Time can be set to a value from 30 to 120 minutes in 10-minute increments. - Not valid when the temperature setting range is restricted. • Password - Administrator password(required for schedule setting etc.)and Maintenance password (required for test run and function setting etc.)can be set SYSTEM EXAMPLE *When a TAR-40MAAU is connected to a group,no other MA remote l l controllers can be connected to the same group. �f Non-polarized Non-polarized y 2-wire 2-wire Deluxe MA Deluxe MA remote remote cm controller ®6 controller Specifications are subject to change without notice. ©2021 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. DIMENSIONS (Front view) (Side view) (Rear view) Unit: mm [in.] 120[4-23/32] 14.5[37/64] I-. • : ...Fiji. n kit* I 0 En 0 0 0 0 COMPATIBILITY CHART SPECIFICATIONS CITY MULIP' lily-Serles P•SeneS Product size In. 4 3l4 x 4 3/4 x 0.57 '.. TPMFYP'BM Yes FKS MAC-334 TPCA Yes (W x H z D) (mm) (120 x 120 x 14.5) TPWFYP'BU Yes WST MAC-334 TPEAD Yes Lbs. 9/18 TPEFYP'MA Yes VVPH MAC-334 TPKA Yes Net Weight (kg) ': (0.25) '.. TPEFY*MH Yes MSY-HM MAC-334 TPLA Yes Rated Power - 12 VDC TPEFY*MS Yes , WMT MAC-334 TPVA Yes Supply Voltage (supplied from indoor units) '.. TPMFY-BM Yes AMT Yes Power Consumption W 0.3 TPLFY'EM Yes DKS Yes P TPLFY'FM Yes CKS Yes.. _... I_. Usage Temperature:0 to 40°C(32 to 104°F) TPKFY'LM Yes UKS MAC-334 Environment Humidity:30 to 90%RH (with no condensation) Note:MAC-334 indicates that the unit PCFY-VKM Yes requires a MAC-3341F-E Adapter in order to use the TAR-4OMAAU Panel PMMA TPCFY'KM Yes Material _-.. _.. _... '.. TPFFY'CS' Yes Main PC+ABS body TPFFY'RE Yes TPVFY'AM Yes Sound Pressure Level TPKFY'BM Yes dB(A) ", <70(A-weighted sound pressure level] TPKFY*HM Yes _. "Per Machinery Directive 2006/421EC FORM#T Submittal TAR-4OMAAU-202103 Specifications are subject to change without notice. 0 2021 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. MODEL: MAC-3341F..E �►w Job Name:Courtyard by Marriott Pool Renovation System Reference:M-net Interface for Controller Date:9/2/2021 • qy � Ffl •He MAC-3341F-E system control interface specifications for Nv-Series indoor units • Allows the Nv-Series indoor units to communicate with the CITY MULTI®Controls Network via M-Net - Room temperature setting by 1°F(0.5°C)for M-NET connection. • Dual Auto mode setting configured by dip switch • External heater ON/OFF based on set and room temperature • Provides two outputs to allow for the following control scenarios: - Note: External 12VDC power supply is required - Equipment Status and Error - Equipment Status and Auxiliary Heat Source - Equipment Status and Humidifier Control - Auxiliary Heat Source and Humidifier Control • Provides an input to allow remote On/Off control of indoor unit(3-Wire plug adapter included) • Allows the Nv-Series indoor units to connect to CN105 interface via CN505 on the MAC-3341F-E when using other MAC-3341F functions - Note:external 12VDC power supply is required - Note: CN105 interfaces that can be used is the Wireless Interface(1 or 2)or MHK1 • Allows the Nv-Series indoor units to connect to a MA remote controller • Operating conditions: indoor only(ambient temperature 32° F to 104° F[0°C to 40° C], no condensation) • Indoor unit connecting cable:dedicated CN105 cable included • In order to have a MAC-3341F-E in the same group as a MAC-3331F-E, DIP switch 502-7 must be set to ON SYSTEM CONFIGURATION Possible components connected with System Control Interface: 1. Centralized Controller (TE-200,TW-50A,TT-24B-J*) 2. System Control Interface(MAC-3341F) 3. Nv-Series indoor unit "5 ,] 4 4. CN105 Interface "' J 5. MA Remote Controller 8 6. Input Contact(field supplied) 7. Output Relay(field supplied) 9 2 3 8. M-Net Power Supply Unit(PAC-SC51 KUA) 9. External 12VDC Power Supply(field supplied) 1 7 10. LMAP04U* / s J r t TT-24B-J is not compatible with LMAPO4U. 7 For details on individual components, 10 please refer to the appropriate manual(s). Specifications are subject to change without notice. ®2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved. Unit: In. (mm) 78-3/4 2000 6-5/16 160) J ---may �® "il6"".6111 Q ININfines mend 17/32I 2-1/8 Holes to fix the interface to the wall (13.5) 5-3/16(132) (54) (2 places indicated by asterisks) COMPATIBILITY Wall-mount Indoor NTYWST/ NTYWST/ Unit NTXWST MSZ-EF NTXWPH NTXWST NTXWMT**A112 NTXWMT**A111 NTXVVEL Outdoor NTXSST NTXMMX NTXSPH NTYSST! NTXSMT**A112 NTXSMT**A111 NTXSEL Unit NTXSST One-way 4-Way Ceiling- Ceiling-Cassette Horizontal Ducted cassette Indoor NTXUKS NTXCKS TPEAD NTXDKS Unit Outdoor NTXSKS NTXSKS NTXSKS NTXSKS Unit Multi-Position Floor-standing air handler Indoor Unit NTXAMT NTXFKS Outdoor NTXSKS NTXSPF Unit MITSUBISHI ELECTRIC Specifications are subject to change without notice. ®2019 Mitsubishi Electric Trane HVAC US LLC.All rights reserved.