Loading...
Report ozi-cxDl.cc ► 0220 SW re4-,%P.�J t25 LINCON Fitness Center RECEIVED Tenant Improvements ` CITY OF TIGARD Material Data Report 3UILDINGDIVISION ZinS t/'�/ For Fire Protection Systems fe Of Your Building 3 LINCOLN TIGARD,OR 10220 SW Greenburg Road 2021/09/09 x i Ulli /111111101111 , . , .t y3 A.P y I� "Ps': rn .gym. , . ; 410 =1 RSw.. t. Yk 1 11 Contents 3 - FIRE SPRINKLERS 13 - PIPE 16 - THREADED FITTINGS liStrY5005 THIRD AVENUE S. 0 F SEATTLE,WA 98134 Jt V l•u •tally 206.762.3311 •MCKINSTRY.COM FIRE SPRINKLERS 5005 THIRD AVENUE S. SEATTLE,WA 98134 MIImFMA 206.762.3311• MCKINSTRY.COM Bulletin 034 February 2021 Reliable') Model G5 Series Sprinklers Standard Spray,Flat Concealed Pendent Available with Gasketed Cover Plate Features • Standard Coverage,Concealed Pendent(K2.8,4.2,5.6,&8.0 [40,60,80,&115 metric]) • Flat concealed cover plate available in a variety of finishes. • Available with Stainless Steel Clad cover plate(see Table I). ., • 3/4-inch (19 mm)cover plate adjustment. • Cover plate available with optional gasket. Model G5 Cover Plate Model G5 Cover Plate Product Description with QR Gasket Model G5 series sprinklers are standard coverage,flat plate concealed sprinklers designed for installation in accordance with NFPA 13 and FM Global Property Loss Prevention Data Sheets.All Model G5 series sprinklers use a fusible-link operating element. The sprinklers are offered with a standard Model G5 cover plate, a Model G5 cover plate with a quick-response(QR)gasket,or a Model G5 cover plate with a standard-response(SR)gasket.Model G5 sprinklers with a gasketed cover plate are intended for use in Model G5 Cover Plate dust free environments such as clean rooms. with SR Gasket Model G5 sprinklers must only be used with the Model G5 cover Note:Gasket material is silicone rubber,available in white only. plate listed or approved with the sprinkler.Table A provides a summary of available Model G5 series sprinklers,along with Listing and Approval information for each sprinkler and cover plate combination. Model G5 Series Sprinkler Summary Sprinkler mf si,� Cover Plate and SensitivityPressure Identification K-Factor Listings Max.WorkingS rinkler i 9P p Model (Umin/bar"2) Model Approvals psi(bar) Number(SIN) G5 cULus OR 2.8 FM SR G5-28 (40) G5 QR Gasket cULus OR 175(12) RA3411 G5 SR Gasket cULus,FM SR G5 G5-42 (60) G5 QR Gasket cULus QR 175(12) RA3413 G5 SR Gasket cULus SR G5 cULus QR 250(17) FM, LPCB, VdS, CE SR 175(12) G5-56 (80) G5 QR Gasket cULus OR 250(17) RA3415 G5 SR Gasket cULus SR 250(17) FM SR 175(12) G5 G5-56 300 (80 G5 OR Gasket cULus QR 300 (21) RA4014 G5 SR Gasket cULus SR G5 8G5-80 ($15) G5 OR Gasket cULus OR 175(12) RA3412 G5 SR Gasket cULus SR G5-80F 8'0 G5 FM SR 175(12) RA3417 (115) G5 SR Gasket www.refiablesprinkler.com Model G5-28 Standard Coverage,Concealed Pendent Sprinkler SIN RA3411 Technical Specifications Sprinkler Temperature Ratings Style:Flat Concealed Pendent 165°F(74°C) `. Threads:'/2"NPT or ISO 7-1 R1/2 212°F(100°C) " Nominal K-Factor:2.8(40 metric) Sensitivity Max.Working Pressure:175 psi(12 bar) (See Table B) k Material Specifications Cover Plates Fusible Link:Beryllium Nickel Model G5 Sprinkler Body:Brass Alloy Model G5 OR Gasket(cULus only) , W Levers:Bronze Alloy Model G5 SR Gasket +' Yoke:Brass Alloy Cover Plate Finishes k Sealing washer:Nickel with PTFE Load Screw:Bronze Alloy (See Table I) Towers:Copper Alloy Sprinkler Wrench a Pins:Stainless Steel Model W3 Deflector:Bronze Alloy Model FC `IeIIr‘o, Cup:Steel Listings and Approvals cULus Listed(Light Hazard only) .ss FM Approved Model G5-28 Sprinkler Components and Dimensions Figure 1 2-5/16" (58 mm) Dia. Threads Body lei -IN ill .i Cup iIaI Ceiling � II ........ ` iri-Tower ndi ...... [ 7 Fusible Link U! 3/4"(19 mm)Max. ' Deflector(retracted) _„...-I I ill Cover Plate Adjustment ' 2,,, 3/16' (5 mm) Pin(extended) j j 1 Deflector(extended) _ L' Model G4/G5 Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model G5-28 Sprinkler Sensitivity Table B Listing or Approval Agency Cover Plate Model cULus FM G5 OR SR G5 OR Gasket QR -- G5 SR Gasket SR SR QR: Quick-response SR:Standard-response Bulletin 034 Reliable Page 2 of 9 February 2021 www.reliablesprinkler.com Model G5-42 Standard Coverage,Concealed Pendent Sprinkler SIN RA3413 Technical Specifications Sprinkler Temperature Ratings Style:Flat Concealed Pendent 165'F(74'C) Threads:1/2"NPT or ISO 7-1 RI/2 212°F(100°C) Nominal K-Factor:4.2(60 metric) Sensitivity Max.Working Pressure: 175 psi(12 bar) (See Table C) _ - s Material Specifications P Cover Plates Fusible Link:Beryllium Nickel Model G5 Sprinkler Body:Brass Alloy Model G5 OR Gasket , ,is . . Levers: Bronze Alloy Model G5 SR Gasket 4^. w Yoke:Brass Alloy Sealing washer: Nickel with PTFE Cover Plate Finishes Load Screw:Bronze Alloy (See Table I) Towers:Copper Alloy Sprinkler Wrench r , Pins:Stainless Steel Model W3 Deflector:Bronze Alloy Model FC Cup:Steel Listings and Approvals cULus Listed(Light Hazard only) Model G5-42 Sprinkler Components and Dimensions Figure 2 2-5/16' (58 mm) Dia. Threads--- Body >�a Cup I_!_!l!_W Ceiling Tower -► i0 ` Fusible Link 3/4"(19 mm)Max. Deflector(retracted) / Cover Plate Adjustment 3/16"(5 mm) Pin(extended) i Deflector(extended)---q.f 34 Model G4/G5 Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model G5-42 Sensitivity Table C Listing or Approval Agency Cover Plate Model cULus G5 OR G5 OR Gasket QR G5 SR Gasket SR QR: Quick-response SR: Standard-response Bulletin 034 Page 3 of 9 February 2021 MEM www.reliablesprinkler.com Model G5-56 Standard Coverage,Concealed Pendent Sprinkler SIN RA3415 Technical Specifications Sprinkler Temperature Ratings Style: hrea Flat Concealed PendentO7-1165°F1 (74°C)1 Threads:'!z"NPT or ISO 7-1 Po/z 212°F(100°C)(cULus,FM,LPCB,CE only) Nominal K-Factor:5.6(80 metric) Sensitivity Max.Working Pressure: (See Table D) 175 psi(12 bar) • Cover Plates 250 psi(17 bar)(cULus only) Model G5 Material Specifications Model G5 OR Gasket(cULus only) Fusible Link:Beryllium Nickel Model G5 SR Gasket(cULus and FM only) Sprinkler Body:Brass Alloy Cover Plate Finishes t ` Levers:Bronze Alloy (See Table I) Yoke:Brass Alloy Sealing washer:Nickel with PTFE Sprinkler Wrench Load Screw:Bronze Alloy Model W3 Towers:Copper Alloy Model FC er.t v�`Y Pins:Stainless Steel Listings and Approvals . .s„ d' Deflector: Bronze Alloy cULus Listed(Light&Ordinary Hazard only) ' ` Cup:Steel FM Approved T rt LPCB Approved . VdS Approved[165°F(74°C)only] CE Listed(2831-CPR-S2062) Model G5-56 Sprinkler Components and Dimensions Figure 3 2-5/16" (58 mm) - Dia. Threads--'— Body mrstri -_-,MI KW---"---.—VII Cup IPA Ceiling - , -, Tower ►+a� ` t►e�aa' Fusible Link 3/4"(19 mm)Max. I I 3/16"(5 mm) Deflector(retracted) 1 Cover Plate AdjustmentNEE I I Pin(extended) j ;; -� --.- - Deflector(extended)--4' _, _ =' ` l Model G4/G5 Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model G5-56 Sensitivity Table D Listing or Approval Agency Cover Plate Model cULus FM LPCB,VdS,CE G5 OR SR SR G5 QR Gasket OR — -- G5 SR Gasket SR SR -- QR:Quick-response SR:Standard-response Bulletin 034 HIM Page 4 of 9 February 2021 www.reliablesprinkler.com Model G5-56 300 Standard Coverage,Concealed Pendent Sprinkler SIN RA4014 Technical Specifications Sprinkler Temperature Ratings Style:Flat Concealed Pendent 165°F(74°C) ;q Threads:lb"NPT or ISO 7-1 RVz 212°F(100°C) b _ Nominal K-Factor:5.6(80 metric) Sensitivity Max.Working Pressure:300 psi(21 bar) (See Table E) Material Specifications Cover Plates Fusible Link:Beryllium Nickel Model G5 F Sprinkler Body:Brass Alloy Model G5 QR Gasket '4'4, .0 Levers:Bronze Alloy Model G5 SR Gasket ,«,:• Yoke:Brass Alloy Cover Plate Finishes Sealing washer:Nickel with PTFE (See Table I) `•qr a�. Load Screw: Bronze Alloy + Towers:Copper Alloy Sprinkler Wrench �^ Pins:Stainless Steel Model W3 Deflector:Bronze Alloy Model FC Cup:Steel Listings and Approvals cULus Listed(Light F.Ordinary Hazard only) Model G5-56 300 Sprinkler Components and Dimensions Figure 4 2-5/16" (58 mm) Dia. Threads Body ii Ii iI Cup '01_R' Ceiling �'r ,''- Tower -ra� ` _► � Fusible Link i 3/4"(19 mm)Max. 1,; 3/16"(5 mm) Deflector(retracted) I Cover Plate Adjustment ;"" .SS Pin(extended)_____ I f �. _� Deflector(extended)— Model G4/G5 Cover Plate 3-5/16"(84 mm)Dia.— Ceiling Model G5-56 300 Sensitivity Table E Listing or Approval Agency Cover Plate Model cULus G5 OR G5 OR Gasket QR G5 SR Gasket SR QR:Quick-response SR: Standard-response Bulletin 034 Page 5 of 9 February 2021 www.reliablesprinkler.com Model G5-80 Standard Coverage,Concealed Pendent Sprinkler SIN RA3412 Technical Specifications Sprinkler Temperature Ratings Style: Flat Concealed Pendent 165'F(74'C) Threads:V."NPT or ISO 7-1 R3/4 212°F(100°C) Nominal K-Factor:8.0(115 metric) Sensitivity t Max.Working Pressure:175 psi(12 bar) (See Table F) Material Specifications Cover Plates 0Fusible Link:Beryllium Nickel Model G5 r Sprinkler Body:Brass Alloy Model G5 OR Gasket 40 b- Levers:Bronze Alloy Model G5 SR Gasket # ✓' Yoke:Brass Alloy Cover Plate Finishes Sealing washer:Nickel with PTFE (See Table I) �r Load Screw:Bronze Alloy ": Towers:Copper Alloy Sprinkler Wrench t., ( i c ; Pins:Stainless Steel Model W3 Deflector: Bronze Alloy Model FC Cup:Steel Listings and Approvals cULus Listed(Light&Ordinary Hazard only) Model G5-80 Sprinkler Components and Dimensions Figure 5 2-5/16" ---(58 mm) - Dia. Threads — Body 111 _ Cup •11 1 1 i. .� ' ' Ceiling �'r 4. Tower _►`! 4— ` ► 7.�_ — -------- Fusible Link 1I 3/4"(19 mm)Max. Deflector(retracted) i Cover Plate Adjustment ism 3/16"(5 mm) 1' Pin(extended) j , t ;cam Deflector(extended) I Model G4/G5 Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model G5-80 Sensitivity Table F Listing or Approval Agency Cover Plate Model cULus G5 QR G5 QR Gasket QR G5 SR Gasket SR QR:Quick-response SR:Standard-response Bulletin 034 Page 6 of 9 February 2021 REM www.reliablesprinkler.com Model G5-8OF Standard Coverage,Concealed Pendent Sprinkler SIN RA3417 Technical Specifications Sprinkler Temperature Ratings Style:Flat Concealed Pendent 165°F(74°C) Threads:7"NPT or ISO 7-1 R3/4 212°F(100°C) • Nominal K-Factor:8.0(115 metric) Sensitivity 7 Max.Working Pressure:175 psi(12 bar) Standard Response Material Specifications Cover Plates ' k Fusible Link:Beryllium Nickel Model G5 �i "' Sprinkler Body:Brass Alloy Model G5 SR Gasket N Levers:Bronze Alloy • Yoke:Brass Alloy Cover Plate Finishes Sealing washer:Nickel with PTFE (See Table I) Load Screw:Bronze Alloy Sprinkler Wrench e..'' Towers:Copper Alloy Model W3 '3 • 4114 Pins:Stainless Steel Model FC Deflector:Stainless Steel Listings and Approvals 41 Cup:Steel FM Approved Silliiiiilli, Model G5-80F Sprinkler Components and Dimensions Figure 6 2-5/16" (58 mm) Dia. Threads Bo Cup IIJJ1!II■ Ceiling Tower —Adirs.41a _ Fusible Link 3/4"(19 mm)Max. - Deflector(retracted) I I Cover Plate Adjustment 3/16"(5 mm) Pin(extended) 1 Deflector(extended)— Model G4/G5 Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model G5-80F Sensitivity Table G Listing or Approval Agency Cover Plate Model FM G5 SR G5SR Gasket SR SR:Standard-response Bulletin 034 Page 7 of 9 February 2021 MEM www.reliablesprinkler.com Installation Dimensions and Cover Plate Information Table H Min.to Max. Min.to Max. Cover Plate Recommended Cover Plate Face of Fitting Dropped Cover Plate Cover Plate Diameter Hole Diameter in Adjustment to Deflector Temperature Ceiling Distance Rating Model Inch Inch Ceiling (mm) Inch (mm) Inch below Ceiling °F (mm) (mm) Inch (°C) (mm) G 3-5/ie (84) 135°F31 3_)ihe (57°C) G5 QR Gasket-) (94) 2-5/8 3/4 1-1/2 to 2-1/4 1/4 to 1 (67) (19) (38 to 57) (6 to 25) or G5 SR Gasket', 4 165°Fw (101 mm) (7474°C) Notes: 1. Face of fitting to ceiling dimensions are based on nominal thread make up.Verify dimensions based on fitting and thread sealing method prior to installation.A 1/"x 1/2"brass nipple extension(Reliable P/N 6999991900)is available to assist with replacement of Reliable Model G4A sprinklers. 2. Model G5 OR Gasket and Model G5 SR Gasket cover plates are sold as assembled units including both the cover plate and gasket. Model G5 QR Gasket and Model G5 SR Gasket cover plates and caskets are not interchangeable, 3. For use with 165°F(74°C)temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F(38°C). 4. For use with 212°F(100°C)temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 150`F(66°C). Cover Plate Finlshest'tj2, Listing & Approval Agencies Standard Finishes Special Application Finishes White Paint Off-White Paint Individual Model G5 series sprinkler may be listed or approved by Chrome'') Black Paint the following agencies: Custom Color Paint(Specify)(3) • Underwriters Laboratories, Inc. and UL Canada(cULus) Raw Brass(Lacquered) Listing Category: Sprinklers,Automatic and Open Bright Brass^! Guide Number:VNIV Finished Bronze ' • FM Approvals (FM) Black Plated 01 • Loss Prevention Certification Board(LPCB) Satin Chrome 14) Stainless Steel Clad(5) • VdS SchadenverhUtung GmbH (VdS) • EC-Certificate of Conformity 0832-CPD-2062(CE) Notes: See Table A and the individual sprinkler data sheets in this Bulletin 1. Paint or any other coating applied over the factory finish will void all for listings and approvals applicable to each sprinkler. approvals and warranties. 2. Cover plates do not carry corrosion resistant listings or approvals. 3. Custom color paint is semi-gloss unless specified otherwise. 4. Not listed for use with OR sealing gasket. Installation 5. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Alloy on the back side. Model G5 series sprinklers are intended to be installed in accordance with NFPA 13, FM Global Property Loss Prevention Application Data Sheets, and the requirements of applicable authorities having jurisdiction. Model G5 series sprinklers must not be Model G5 series sprinklers are standard coverage,flat plate installed in ceilings with positive pressure in the space above. concealed pendent sprinklers.The sprinklers are intended for Ensure that the 4 slots in the cup are open and unobstructed use in accordance with NFPA 13 and FM Global Property Loss following installation. Prevention Data Sheets, as well as the requirements of the Model G5 series sprinklers are shipped with a wrench-able applicable approval agencies. protective cap that should remain on the sprinkler until the sprinkler system is placed in service following construction. Model G5 series sprinklers are available as either Quick-response Model G5 series sprinklers can be installed without removing (QR) or Standard-response (SR)depending on the approval the wrench-able protective cap using the Model W3 wrench. agency and cover plate selected. Alternatively, Model G5 series sprinklers can be installed using the Model FC wrench by temporarily removing the protective cap Model G5 series sprinklers use Model G5 flat cover plates. Model during installation of the sprinkler.The use of any other wrench G5 QR Gasket and G5 SR Gasket cover plates are available to to installed Model G5 series sprinklers is not permitted and may limit air and dust movement through the ceiling. damage the sprinkler. Bulletin 034 Page 8 of 9 February 2021 MON www.reliablesprinkler.com Wrench 11111) r"> Model FC Model W3 For use with Model G5 Series sprinklers For use with Model G5 Series sprinklers with without wrench-able cap installed wrench-able cap installed Fully insert the Model W3 wrench over the cap until it reaches Replace any sprinkler or cover plate which has been painted(other the bottom of the cup, or the Model FC wrench over the sprinkler than factory applied). Properly installed Model G5 cover plates will until the wrench engages the body. Do not wrench any other have an air gap that is required for proper operation, do not seal part of the sprinkler/cup assembly.The Model W3 and FC the gap or paint the cover plates. Model G5 series sprinklers have wrenches are designed to be turned with a standard 1/2"square holes in the cup that must remain unobstructed. drive.lighten the sprinkler into the fitting after applying a PTFE Replace any sprinkler which has been damaged.A stock of spare based thread sealant to the sprinkler's threads. Recommended sprinklers should be maintained to allow quick re-placement installation torque is specified in Table J. of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non-operation during a fire event. Installation Torque Table J Recommended Installation Guarantee Sprinkler Threads Torque (min.—max.) For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, ft.lb N.m and conditions,visit www.reliablesprinkler.com. '/2"NPT or ISO7-1 R1/2 8-18 11-24 ' "NPT or ISO7-1 R3/4 14-20 19-27 Patents Do not exceed the maximum recommended torque.Exceeding the Model G5 series sprinklers may be covered by one or more of the maximum recommended torque may cause leakage or impairment following patents: of the sprinkler. Use care when inserting or removing the wrench U.S. Patent 6,554,077, U.S. Patent 7,275,603, U.S. Patent from the sprinkler to avoid damage to the sprinkler. 8,776,903, U.S. Patent 9,248,327 Install the cover plate by hand,pushing and then turning the cover Ordering Information in the clockwise direction until it is tight against the ceiling. For Specify the following when ordering. Model G5 QR Gasket and Model G5 SR Gasket cover plates,the gasket should be attached to the flange of the cover plate skirt Sprinkler only. Do not glue the gasket in place or allow the gasket to overlap • Model[G5-28][G5-42][G5-56][G5-56 300] both the cover plate and the flange of the skirt. [G5-80][G5-80F] • Temperature Rating[165°F(74°C)] [212°F(100°C)] Maintenance • Threads[NPT or ISO 7-1] Reliable Model G5 series sprinkler should be inspected and the Cover Plate sprinkler system maintained in accordance with NFPA 25, as well • Model[G5, G5 QR Gasket, G5 SR Gasket] as the requirements of any Authorities Having Jurisdiction. • Finish(See Table I) Prior to installation,sprinklers should remain in the original cartons Sprinkler Wrench and packaging until used. This will minimize the potential for • Model W3 damage to sprinklers that could cause improper operation or non- • Model FC operation. Do not clean sprinklers with soap and water,ammonia liquid or any v other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. rn a) a, a, z Bulletin 034 NEM Page 9 of 9 February 2021 www.reliablesprinkler.com PIPE 5005 THIRD AVENUE S. SEATTLE,WA 98134 einstry n Cr ror unafl 206.762.3311 •MCKINSTRY.COM _ � � Mg Mg I' . ve a i?'' d a # - ti - - _ _ _ o .—. $ w'MI " MI — — — - _ _ ° -_ o _ M 77 Mg - ac.. Y i) II.. Miii _ -_ - ar _ — - M1I -g, k - NM - ^-� _ - :1.1 s i r ' Z.' — am _ _ Itas _ _ no - _ _ _ _ _ i _ _ - _ — - - » of , • RINKLER PIP�� Trust Bull Moose when it comes to protecting your most valuable assets. As the leading manufacturer of steel sprinkler pipe, we understand that there are no second chances in fire suppression. You need products of enduring quality and exceptional strength-plus reliable service. You need Bull Moose. BULL MOOSE ADVANTAGES: OTHER BENEFITS/SERVICES: • UL listed(US&Canada)and FM approved • We have the most stocking locations in industry,for best delivery and availability • ASTM A135 and A795 Type E, Grade A Certified • Plain end or roll groove • Complies with NFPA-13,13R and 14 • Eddy Guard IIJ bacterial-resistant internal coating • Industry-leading hydraulic characteristics. • Custom length options • CRR of 1.0 and greater • Hot dipped galvanization • All pipe NDT weld tested • Reddi-Pipe®red pipe to eliminate field painting Exclusive maker of Reddi-Pipe® • Compatible for use in wet,dry,preaction and deluge sprinkler systems red painted pipe. w c®os LISTED Q APPROVE® lml NFPA A..,..- ,. SonnF:n Assocla:len £ • �.. 1 .� . 5•.I= 800.325.4467 �„ ,,.. sales®bullmooseindustries.com BU . ., MOOSE . q (�� s ,filif 1 I :.._.`�'�y"` ` 1Jli .. Bull Moose Fire Sprinkler Pipe Product Information Nominal Pipe Size(Inches) 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 4" 6" 8" 00.;10 1.660 1.900 2.375 2.875 3.500 4.500 i.0.(in) 1.530 1.728 2.203 2.705 3.334 4.310 Empty Weight(Ib/ft) 1.222 1.844 i 2.330 2.809 3.361 4.968 OJ Water Filled Weight(Ib/ft) 2.019 2.860 3.982 5.299 7.144 11.290 L.L. C.R.R. 1.98 3.44 2.78 1.66 1.00 1.00 G Pieces per Litt 61 61 37 30 19 19 W Lift Weight(Ibs)21'lengths 1,565 1 2,362 1,810 1,770 1,341 1,982 Lift Weight(Ibs)24'lengths 1,789 2,700 2,069 2,022 1,533 2,265 Lift Weight(Ibs)25'lengths 1,864 2,812 2,155 2,107 1,596 2,360 On (in) 1.315 1.660 1.900 2.375 2.875 3.500 4.500 6.625 8.625 ID.(in) 1.097 1.442 1.682 2.157 2.635 3.260 4.260 6.357 l 8.249 Ct— Empty Weighthb/ft) 1.410 1.810 2.090 2.640 3.530 4.340 5.620 9.290 16.940 W water Filled Weight hb/ft) 1.820 2.518 3.053 4.223 5.893 7.957 11.796 23.038 40.086 _G E.R.R. 15.27 i 9.91 7.76 6.27 4.92 3.54 2.50 1.158 1.805 1, W = Pieces per Lift 91 61 61 37 30 19 19 10 1 u Lift Weight(Ibs)21'lengths 2,695 2,319 2,611 2,051 2,224 1,732 2,242 1,951 2,490 Lift Weight(Ibs)24'lengths 3,079 2,650 3,060 2,344 2,542 1,979 2,563 2,230 2,848 Lift Weight(Ibs)25'lengths 3,208 2,760 3,187 2,442 2,648 2,062 2,670 0.0.(in) 1.295 1.650 1.900 2.375 p 10.(in) 1.083 1.418 1.545 2.123 locr Empty Weight hb/ft) I 1.461 2.070 2.547 330E 'Q Water Filled Weight(lb/ft) 1.860 2.754 3.468 4.842 W _ C R.R. I 1.00 1.00 1.00 1.00 _ - ~ Pieces per Lift 70 51 44 30 G Lift Weight(Ibs)21'lengths 2,148 2,211 2,353 2,084 C3 W Lift Weight(Ibs)24'lengths 2,454 2,534 2,690 2,382 Lift Weight(Ibs)25'lengths 2,557 2,639 2,802 2,481 11 0.0.(in) 1.315 1.660 1.900 2.375 2.875 3.500 4.500 I.O.(in) 1.049 1.380 1.610 2.067 2.469 3.068 4.026 G Empty Weight(Ib/ft) 1.680 2.270 2.720 3.660 5.800 7.580 10.800 W I Water Filled Weight(Ib/ft) 2.055 2.918 3.602 5.114 7.875 10.783 16.316 J —* 2 C R.R. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0 W Pieces per Lift 70 51 44 30 30 19 19 LA Lift Weight(lbs)21'lengths 2,470 2,431 2,513 2,306 3,654 3,024 4,309 Lift Weight(lbs)24'lengths 2,822 2,778 2,872 2,635 4,176 3,456 4,925 Lift Weight Ohs)25'lengths 2,940 2,894 2,992 2,745 4,350 3,601 5,130 800 325.4467 BULL ]V[OOSE— salesCa bUHmooseindu tries. o u1INl00SETube.com THREADED FITTINGS 5005 THIRD AVENUE S. einstry SEATTLE,WA 98134 m%.s.nn.y 206.762.3311 •MCKINSTRY.COM SECTION 10 TEELOXTM MECHANICAL BRANCH CONNECTOR Designed for fast installation of bolted branch outlets, �- TeeloxlM mechanical branch connectors are practical alternatives to existing branch connect systems. Made from high quality cast iron, TeeloxTM are tip,, .„,,,, known for long-lasting, maintenance-free performance. Key Features: ,. • A high grade EPDM rubber gasket surrounds the . locating collar for accurate, permanent installation '� , } _ and the best seal in the industry. • The locating collar is an integral part of the casting. _ _ • A zinc-plated high-tensile steel U-bolt ensures rust-free aTl attachment. `" • TeeloxTM is approved for conventional and arm-over installations. Pipe Center Hole Dia. Take NPS to Outlet B Out c A Pr 1 1/4 x 1/2 1.98 1.19 1.19 11/4x3/4 2.05 1.19 1.19 1 I ==330�� R 1 1/4 x 1 2.13 1.19 1.19 1 1/2x 1/2 1.98 1.19 1.19TAKE OUT 1 1/2x3/4 2.05 1.19 1.19 11/2x1 2.13 1.19 1.192x1/2 2.26 1.19 1.47liii 2x3/4 2.33 1.19 1.472x1 2.41 1.19 1.47 21/2x1/2 2.57 1.19 1.78 2 1/2 x 3/4 2.64 1.19 1.78 2 1/2 x 1 2.72 1.19 1.78 Material: Cast Iron ASTM A126 Class A Minimum Gasket: E.P.D.M. Rubber ASTM D-2000 U Bolt: Zinc Plated High-Tensile Steel Dimensions: ANSI/ASME B1.20.1 Pressure Ratings: 175 psi Coatings: ASTM B633, ASTM A153 Additional UL,ULC and FM where applicable Specifications: Torque 20 ft.-lbs.max. Requirement 80 5PF/ANVIL" DUCTILE IRON THREADED FITTINGS ®4M/1I_ FIG. 3201 90° Elbow Eyhu .. A usreo APPROVED For Lis[ings/Approval Details and Limttations, visit our mesas at wens anolintl.com or tooted an AnviN Sales Representative. FIGURE 3201 - 90° ELBOW MATERIAL SPECIFICATIONS Nominal Size Maximum Dimension A Approx.WI.Each Dimensions: ASME B 16.3 Working Pressure In.(aim) PSI(kPo) In.(mm) lbs.(kg) Material: ASTM A536 Grade 65-45-12 1 500 1.50 0.62 Finish: Black 345C 0.23 11/4 500 1.75 0.90 Threads: NPT per ASME B1.20.1 3% 3450 .945 1.20�4' Agency Approvals: All ductile iron threaded fittings are l Y2 500 1.94 9 Y PP 40 3450 49.276 0.54 UL/ULC Listed and FM Approved. 2 500 2.25 1.85 50 3450 57.I 0.84 NOTICE Ductile iron fittings have higher tensile strength than that of steel pipe. A—Working Pressure Ratings are for reference only and based on Sch.4a pipe.For the Therefore,over tightening can cause damage to pipe threads which may cause latest UL/ULC,and FM pressure ratings versus pipe schedule,please visit anvilind.com or leakage.Ductile iron fittings should be tightened approximately three turns beyond contact your local Anvil Representative. hand tight,but no more than four turns. PROJECT INFORMATION APPROVAL STAMP Project: ❑Approved Address: ❑Approved as noted Contractor: ❑Nat approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 SPF/ANVIL' ) DUCTILE IRON THREADED FITTINGS = 4Nv!L FIG. 3201R Reducing 90° Elbow r . �B-► I r 2 i + __T_---- - C115 41> A LISTED APPROVED 1 For Listings/Approval Details and Limitations, visit our bsite at anvilinti.corn or 1 X 2 contact anaAnvl Sales Representative. FIGURE 3201R - REDUCING 90° ELBOW MATERIAL SPECIFICATIONS Nominal Size Max.Working Dimensions Approx. 1 x 2 Pressurei, A B Wt.Each Dimensions: ASME B16.3 In.(mm) PSI(kPa) fn.(cam) In.(cam) lbs.(kg) Material: ASTM A536 Grade 65-45-12 1 x'b 500 1.26 1.36 0.44 Finish: Black 25 x 15 3450 3200 34.54 0.20 1 xVi 500 1.37 1.45 0.52 Threads: NPT per ASME B1.20.1 25 x 20 3450 34.79 36.83 024 Agency Approvals: All ductile iron threaded fittings are 1'/,x'h 500 1.34 1.53 0.64 UL/ULC Listed and FM Approved. 32 x 15 34550 34.03 38.86 029 11/4 x r/ 500 1.45 1.62 0.72 32x 20 3450 36.83 41.14 0.33 NOTICE:Ductile iron fittings have higher tensile strength than that of steel pipe. 1'/x 1 500 1.58 1.67 0.75 Therefore,over tightening can cause damage to pipe threads which may cause leakage.Ductile iron fittings should be tightened approximately three turns beyond 32x 25 3450 40.13 42.41 0.34 hand tight,but no more than four sums. 1 V2 x I 500 1.65 1.80 0.92 40425 3450 41.91 45.72 0.42 11/2 x 1'% 500 1.82 1.88 1.08 40432 3450 46.22 47.15 0.49 2 x1/2 500 1.49 1.88 1.08 50x 15 3450 3184 47.75 0.49 2 x/ 500 1.60 1.97 1.24 50420 3450 4264 50.03 0.56 2 x 1 500 1.73 2.02 1.40 50 x 25 3450 43.94 51.30 0.64 2 x 1Y, 500 1.90 2.10 1.52 50x32 3450 48.26 53.34 0.70 2 x 1'/I 500 2.02 2.16 1.65 50 x 40 3450 5430 54.86 0.15 A-Working Pressure Ratings are for reference only and based on Sch.40 pipe.For the latest UL/ULC,and FM pressure ratings versus pipe schedule,please visit anvilintl.com or contact your local Anvil Representative. PROJECT INFORMATION APPROVAL STAMP Project: ['Approved Address: ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 sPFiannrtc DUCTILE IRON THREADED FITTINGS ii(z;),AMivN FIG. 3202 45° Elbow at . f Ous 41> A I LISTED APPROVED I For Listings/Approval Details end Limitations. visil our o 1 contact an AnviP Sales Representative. FIGURE 3202 - 45° ELBOW MATERIAL SPECIFICATIONS Nominal Size Maximum Dimension A Approx.Wt.Each Working Pressure. PP Dimensions: ASME B16.3 In.(mm) PSI(kPa) In.(mm) tbs.(kg) Material: ASTM A536 Grade 65-45-12 1 500 1.12 0.46 3460 284 Finish: Black 11/4 500 1.29 0.73 Threads: NPT per ASME B 1.20.1 32 500 3 0.33 Agency Approvals: All ductile iron threaded fittings are 11/2 500 1.43 0.92 40 3450 3632 0.42 UL/ULC Listed and FM Approved. 2 500 1.68 1.50 50 3450 42.61 0.68 NOTICE:Ductile iron fittings have higher tensile strength than that of steel pipe. A—Working Pressure Ratings are for reference only and based on Sch.40 pipe.For the Therefore,over tightening can cause damage to pipe threads which may cause latest UL/ULC,and FM pressure ratings versus pipe schedule,please visit anvilinil.com or leakage.Ductile iron fittings should be tightened approximately three turns beyond contact your local Anvil Representative. hand tight,but no more than four turns. PROJECT INFORMATION APPROVAL STAMP Project: ❑Approved Address: 0 Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 • SPF/RNVIL' DUCTILE IRON THREADED FITTINGS (Cz�&nivi FIG. 3205 Straight Tee w_ T ' A On 41> 11S/E11 APPROVED For Listings/Approval Details and Limitations. t visit our website at www.anvilNtl.com Or contact an Anvil*Sales Representative. I<-A--E—A FIGURE 3205 - STRAIGHT TEE MATERIAL SPECIFICATIONS Nominal Size Maximum Dimension A Approx.Wt.Each Working Pressure. Pp Dimensions: ASME B16.3 In.(mm) PSI(kPa) In.(mm) Lbs.(kg) Material: ASTM A536 Grade 65-45-12 1 500 1.50 0.85 Finish: Black 342 JC.IU, 0.39 P/< 500 1.75 1.22 Threads: NPT per ASME B1.20.1 32 3450 44.4 055 Agency Approvals: All ductile iron threaded fittings are 1 Y 500 1.94 1.55 40 3450 49.27 0.70 UL/ULC Listed and FM Approved. 2 500 2.25 2.45 50 3450 57.15 1.11 NOTICE:Ductile iron fittings have higher tensile strength than that of steel pipe. A—Working Pressure Ratings ore for reference only and based on Sch.40 pipe.For the Therefore,over tightening can cause damage to pipe threads which may cause latest MARC,and FM pressure ratings versus pipe schedule,please visit anvilintl.com or leakage.Ductile iron fittings should be tightened approximately three turns beyond contact your local Anvil Representative. hand tight,but no more than four turns. PROJECT INFORMATION APPROVAL STAMP Project: 0 Approved Address: ['Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 5PF/R1s.n DUCTILE IRON THREADED FITTINGS (z)AM/IL FIG. 3205R Reducing Tee �- C -- 1-- 2 B 1 I 3 USSEII APPROVED A 1 1 For listings/Approval Details and Limitations. -- 1 X 2 x 3 visit our4Jt5i alaes epresen t or contactf an Anvir Sales Representative o. I FIGURE 3205R - REDUCING TEE MATERIAL SPECIFICATIONS Nominal Size Max. Dimensions Working Approx. Wt. Each Dimensions: ASME B16.3 1 x 2 x 3 Pressure. A 8 Material: ASTM A536 Grade 65-45-12 In.(mm) PSI GP& In.(mm) In.(mm) In.(mm) lbs.(kg) Finish: Black 1 x lh x 1 500 1.501.361.500.64NPT per ASME B 1.20.1 25 x 15 x 25 3450 38.1.10 34.5.54 38.1.10 0.29 29 Threads: 1 x3/4x 1 500 1.50 1.45 1.50 0.73 Agency Approvals: All ductile iron threaded fittings are 25x20x25 3450 38.10 3683 3810 0.33 UL/ULC Listed and FM Approved. l x 1 x'h 500 1.26 1.26 1.36 0.71 25 x 25 x 15 3450 32.00 32.00 34.54 0.32 1 x 1 xi, 500 1.37 1.37 1.45 0.76 NOTICE:Ductile iron fittings have higher tensile strength than that of steel pipe. 25 x 25 x 20 3450 34.80 34.80 36.83 0.34 Therefore,over tightening can cause damage to pipe threads which may cause 1 X 1 x 1'/<* 500 1.b1 1.67 1.58 0.98 leakage.Ductile iron fittings should be tightened approximately three turns beyond hand tight,but no more than four turns. 25 x 25 x 32 3450 42.4! 42 41 40.13 0.44 l x 1 x 1'/* 500 1.80 1.80 1.65 1.16 25x25x40 3450 45.72 45.72 41.91 0.53 FIGURE 3205R - REDUCING TEE 11/4 x 1 x'/:* 500 1.34 1.26 1.53 0.82 32x25x I5 3450 34.04 3200 38.86 0.37 Nominal Size Max. Dimensions 1V4 x 1 x 3/ 500 1.45 1.37 1.62 0.90 ' Working Approx. 32x25x20 3450 3683 34.80 41.15 0.41 1 x 2 x 3 Pressure& A B E Wl.Each 1'/+x 1 xl 500 1.58 1.50 1.67 1.00 ( ) PSI(kPo) In.(min) In.(mm) In.(mm) lbs.(kg) 32 x 25 x 25 3450 40.13 38.10 42.42 0.45 g 1'/4 x 1 x 1'b 500 1.75 1.67 1.75 1.08 1 lh x 1'/+x 3/ 500 1.45 1.45 1.62 0.92 32 x 25 x 32 3450 44.45 42.41 44.45 0.49 32 x 32 x 20 3450 36.83 36.83 41.15 0.42 11/4 x 1 x 11/2 500 1.88 1.80 1.82 1.42 11/4 x 1%x l 500 1.58 1.58 1.67 0.95 32 x 25 x 40 3450 47.75 45.72 46.22 0.64 32 x 32 x 25 3450 40.13 40.13 42.42 0.43 1'/4 x 1 lA x'h 500 1.34 1.34 1.53 0.86 l'/i x l%x 1'A* 500 1.88 1.88 1.82 1.45 32 x 32 x 15 3450 34 04 34 04 38.86 0.39 32 x 32 x 40 3450 47.75 47.75 46.22 0.66 ♦Working Pressure Ratings are for reference only and based on Sch.40 pipe.For the latest UL/ULC,and FM pressure ratings versus pipe schedule,please visit anvilintl.com or contact your local Anvil Representative. * Part supplied as"Bull Head Tee". PROJECT INFORMATION APPROVAL STAMP Project: ❑Approved Address: D Approved as noted Contractor: ['Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 SPF/RNV DUCTILE IRON THREADED FITTINGS = /1NviL FIG. 3205R Reducing Tee .-6,- C -- 2 F , ' 1 1 mormil 1x2x3 FIGURE 3205R - REDUCING TEE FIGURE 3205R - REDUCING TEE Nominal Size Max. Dimensions Nominal Size Max. Dimensions Working Approx. Working Approx. 1 x 2 x 3 PressureA A B ( Wt.Each 1 x 2 x 3 PressureA A B ( Wt.Each In,(mm) PSI(kPo) In.(mm) In.(mm) In.(mm) Lbs.(kg) In.(mm) PSI(kPo) In.(mm) In.(mm) In_(mm) tbs.(kg) 1/x11/4x2* 500 2.10 2.10 1.90 1.75 1/x1/02* 500 2.16 2.16 2.02 1.98 32 x 32 x 50 3450 53.34 53 34 48.26 0.72 40 x 40 x 50 3450 54.86 54.86 51.30 0.90 1'/2 x 1 x'/2 500 1.41 1.34 1.66 0.95 2 x 1 x 2 500 2.25 2.02 2.25 2.15 40 x 25 x 15 3450 35.81 34 04 4216 0.43 50 x 25 x 50 3450 57.15 51.31 57.15 0.98 1/x1x2/4 500 1.52 1.37 1.75 1.14 2x11/2x2 500 2.25 2.10 2.25 2.30 40 x 25 x 20 3450 38.61 34.80 44.45 0.52 50 x 32 x 50 3450 57.15 53.34 57.15 1.04 1/2xlx1 500 1.65 1.50 1.80 1.17 2x11/2x1/2 500 1.49 1.41 1.88 1.50 40x25x25 3450 41.91 38.10 45.72 0.53 _ 50x40x15 3450 37.85 35.81 47.75 0.68 1'/2 x 1 x 1'/4 500 1.82 1.67 1.88 1.34 2 x 11/2 x 3 500 1.60 1.52 1.97 1.62 40 x 25 x 32 3450 46.23 42.42 47.75 0.61 50 x 40 x 20 3450 40.64 38.61 50.04 0.73 11/4 x 1 x 11/4 500 1.94 1.80 1.94 1.45 2 x 11/2 x 1 500 1.73 1.65 2.02 1.64 40 x 25x 40 3450 49.28 45.72 49.28 0.66 50 x 40 x 25 3450 43.94 41.91 51.31 0.74 11/2 xl'/x'/2 500 1.41 1.34 1.66 1.05 2 x 1/2 x 1'A 500 1.90 1.82 2.10 1.80 40 x 32 x 15 35.81 34.04 42.16 0.48 50 x 40 x 32 3450 48.26 46.23 53.34 0.82 1'/2 xl'/x 3% 500 1.52 1.45 1.75 1.15 2 x 11/2 x 1/n 500 2.02 1.94 2.16 2.00 40x32x20 3450 38.61 36.83 44.45 0.5 50x40x40 3450 51.31 49.28 54.86 0.91 1'/2 x 1'/4 x 1 500 1.65 1.58 1.80 1.25 2 x 1'/2 x 2 500 2.25 2.16 2.25 2.35 40 x 32 x 25 3450 41.91 40.13 45.72 0.57 50 x 40 x 50 3450 57.15 54.86 57.15 1.07 1'/2 x 1'//x 2* 500 2.16 2.10 2.02 1.90 2 x 2 x'h 500 1.49 1.49 1.88 1.60 40 x 32 x 50 3450 54.86 53.34 51.30 0.86 50 x 50 x 15 3450 37.85 37.85 4775 0.73 11/2x11/4x1/2 500 1.41 1.41 1.16 1.15 2x2x3/4 500 1.60 1.60 1.97 1.68 40x40x15 3450 35.81 35,81 29.46 0.52 50x50x20 3450 40.64 40.64 50.04 0.76 11/2 x 1'/2 x s/4 500 1.52 1.52 1.75 1.24 2 x 2 x 1 500 1.73 1.73 2.02 1.85 40 x 40 x 20 3450 38.61 38.61 44.45 0.56 50 x 50 x 25 3450 43.94 43.94 51.31 0.84 11/2 x 11/2 x 1 500 1.65 1.65 1.80 1.30 2 x 2 x 1%4 500 1.90 1.90 2.10 2.04 40x40x25 3450 41.91 41.91 45.72 0.59 50x50x32 3450 44.45 42.42 44.45 0.93 11/4 x l'/2 x 11/4 500 1.82 1.82 1.88 1.48 2 x 2 x 1'/2 500 2.02 2.02 2.16 2.18 40 x 40 x 32 3450 46.23 46.23 47.75 0.67 50 x 50 x 40 3450 44.45 42.42 44.45 0.99 ♦Working Pressure Ratings are for reference only and based on Sch.40 pipe.For the latest UL/ULC,and FM pressure ratings versus pipe schedule,please visit anvilintl.com or contact your local Anvil Representative. * Part supplied as"Bull Head Tee". SPF/DI-1.15 SPF/ANVIL' DUCTILE IRON THREADED FITTINGS �z� nivi FIG. 3221 Coupling A Os 41> - ---i--- — USIFD APPROVED For LislingslApproval Details and Limitations, alert our webstie at www.anvilintl.aom or contact an Anvil*Sales Representative. FIGURE 3221 - COUPLING MATERIAL SPECIFICATIONS Nominal Size Maximum Dimension A Approx.Wt.Each Dimensions: ASME B 16.3 Working Pressure In.(mm) PSI(kPe) _ In.(mm) uu.(kg) Material: ASTM A536 Grade 65-45-12 1 500 1.67 0.40 Finish: Black 25 _ 42.42 0.18 500 1.93 0.57 Threads: NPT per ASME B1.20.1 32 49.02 0.26 Agency Approvals: All ductile iron threaded fittings are 0 2.15 0. 40 3UL/ULC Listed and FM A roved. 4.55o 54 s4.61 0 34 pp 2 500 2.53 1.15 50 3450 6426 0.52 NOTICE:Ductile iron fittings have higher tensile strength than that of steel pipe. —Working Pressure Ratings are for reference only and based on Sch.40 pipe.For the Therefore,over tightening can cause damage to pipe threads which may cause latest UL/ULC,and FM pressure ratings versus pipe schedule,please visit anvilintl.com or leakage.Ductile iron fittings should be tightened approximately three turns beyond contact your local Anvil Representative. hand tight,but no more than four turns. PROJECT INFORMATION APPROVAL STAMP Project: ❑Approved Address: ❑Approved as noted Contractor: ❑Noi approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 1;;F/RNVIL' DUCTILE IRON THREADED FITTINGS 1: I4NVI<: FIG. 3221R Reducing Coupling .li a®. A USTEI APPROVED For Listings/Approval Details end Limitations, Visit our website at W os envitinll Lom or contact an Anvil.Sales Representative. FIGURE 3221R - REDUCING COUPLING MATERIAL SPECIFICATIONS Nominal Size Maximum Dimension A Approx.WI.Each Dimensions: ASME B16.3 Working Pressure. In.(mm) PSI(kPo) In.(mm) lbs.(kg) Material: ASTM A536 Grade 65-45-12 l x'/t 500 1.69 0.39 Finish: Black 25 A 15 3450 a,"% 1 x3/4 500 1.69 0.53 Threads: NPT per ASME B1.20.1 25 x 20 3450 42.92 024 Agency Approvals: All ductile iron threaded Fittings are ♦-Working Pressure Ratings are for reference only and based on Sch.40 pipe.For the latest uL/uLC,and FM pressure ratings versus pipe schedule,please visit anvilinfl.cam or UL/ULC Listed and FM Approved. contact your local Anvil Representative. NOTICE:Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore,over tightening can cause damage to pipe threads which may cause leakage.Ductile iron fittings should be tightened approximately three turns beyond hand tight,but no more than four turns. PROJECT INFORMATION APPROVAL STAMP Project: ❑Approved Address: ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/DI-1.15 SPF/FINVIL' DUCTILE IRON THREADED FITTINGS (- )AIvvi4 FIG. 3224 Cap i Y it ?' .y„Y ,,�zprT r; ( W W a � f YYt A _„,., LISTED APPROVED 1 -""^+ For Llsb gslApproval Details and Limitations, visit our Webslle at mew anvlllntl.com or contact an Anvil°Sales Representative. FIGURE 3224 - CAP MATERIAL SPECIFICATIONS Nominal Size Maximum Dimension A Approx.Wt.Each Dimensions: ASME B 16.3 Working Pressure In.(nun) PSI(kPo) In.(mm) Ibs.(kg) Material: ASTM A536 Grade 65-45-12 1 500 1.16 0.32 Finish: Black 25 3450 29 do 015 11/ 500 1.28 0.43 Threads: NPT per ASME 31.20.1 32 3450 3251 010 Agency Approvals: All ductile iron threaded fittings are llh 500 1.33 0.60 40 3450 3378 0 p UL/ULC Listed and FM Approved. 2 500 1.45 0.91 50 3450 36-83 0.41_ NOTICE:Ductile iron fittings have higher tensile strength than that of steel pipe. ♦-Working Pressure Ratings are for reference only and based on Sch.40 pipe.For the - Therefore,over tightening can cause damage to pipe threads which may cause latest UL/ULC,and FM pressure ratings versus pipe schedule,please visit anvilintl.com or leakage.Ductile iron fittings should be tightened approximately three turns beyond contact your local Anvil Representative hand tight,but no more than four turns. PROJECT INFORMATION APPROVAL STAMP Project: ['Approved Address: ❑Approved as noted Contractor: ['Nat approved Engineer: Remarks: Submittal Dale: Notes 1: • Notes 2: SPF/DI-1.15 SUBMITTAL PACKAGE ,„ 7i X(' `k + qY 400gp311—P' I i i. • i. RY Y„, •Ys fr'... t I "1,dt s i,„„ &9iR T Ys{`a` as 4{R.. ..' 4YY 4 dT iil if 4dl. #Yi .+ sY 4 P *Al. 4 1 1 j ' ♦ 41 d frr* ,:* Y.t rs 4 q .. N;izz: Y 1• ws F . + - • , `.=, r 0 ` .w 4"4 > „a • §, MYe�M' y .yN �•.. £r a a j r t' x. a' II I , , . e, C ® �� FLEXHEAD ,t FBc', _..,.. . a brand of ((Il ../) 1L <OMPPiWtF SeMaE APPROVED �� 1F " r •'` 4s5'a ;�tiwr aa�rm we{ae.,d.h�yr;,uresa :%e%a rit ✓,,a% a.*.,✓s:,+iy. We invented the concept of flexible fire protection TM The FlexHeadR Advantage FLEXHEAD:' QUALITY FLEXHEAD' FEATURES • Best corrosion resistance • Is seismically qualified for use, Made from 100% 304 stainless steel eliminating the need for an oversized • Excellent friction loss values ring around the sprinkler head in One-inch true-bore ID reducing the seismic areas need to upsize mains and branch lines, • Has the same product design that is 1'/4" available dual listed by both UL and FM • Pressure surge protection • Can be produced domestically to Fully braided connection improves meet all your project requirements pressure capability and prevents • Has serial identification with complete hose damage audit tracking of finished goods • Highest maximum working pressure • Has a comprehensive limited warranty Rated up to 300 psig backed by an A++ insurance company ■ No o-rings or gaskets Welded • Offers a variety of flexible fire sprinkler connections reduce potential leak connections, suspended ceilings, points at the inlet and outlet fitting gypsum board ceilings, institutional • Tightest thread tolerances applications, cleanroom and duct Outlet fitting threads are machined from applications solid bar stock reducing potential leaks • Offers 1.25" FlexHead® hose for superior at the sprinkler head fit-up friction loss numbers ■ Extra stability Bracket has a full 6-inch base to stabilize the sprinkler head during installation, pressurization or activation ! iI r � 1 TABLE OF OF CONTENT a �• i+Y Ie(°1s', y }f"+ Introduction 2 Table of Contents 3 Installation Instructions 4 - 7 NFPA 13 Code Language and Seismic Qualification 8 - 9 Friction Loss Data and Specifications 10 - 11 Suspended Ceiling Detail 12 Hose Specification Sheet 13 Bracket Specification Sheet 14 FlexHead'- Commercial Products 15 FlexHead Sprinkler Hose Fittings 16 Warranty 17 Whether your application is commercial, industrial, clean room, or institutional, FlexHeacr flexible sprinkler systems can save you time and money by offering reli- able, highly efficient, seismically qualified, and environmentally responsible products. U.S.and international patents pending:#6,123,154,#6,119,784,#6,752,218,#7,032,680,#6,488,097. The FlexHead®name and logo are trademarks of FlexHead Industries, Inc. FGG/BM/CZTM System Compatible indicates that this product has been tested,and is monitored on an ongoing basis,to assure its chemical compatibility with FlowGuard Gold®,BlazeMaster®and Corzan®pipe and fittings. FGG/BM/CZTM,FlowGuard Gold®, BlazeMaster®,and Corzan®are licensed trademarks of The Lubrizol Corporation USGBC and LEED are registered trademarks of the U.S.Green Building Council.The FlexHead®Commercial Products have been tested and evaluated by Spears®for acceptable use with FlameGuard®CPVC Fire Sprinkler products. 800.829.6975 We invented the concept of flexible fire protectionTM INSTALLATION INSTRUCTIONS - MPT-24-BKT1 Installation of FlexHead Commercial Ceiling T Bar Ceiling Grid Installation Flexible Sprinkler Drop System The MPT bracket is designed for use on ceiling grids conforming to ASTM C 635*. Recommend the use of proper PPE for installation. MPT-24-BKT1 is approved for use with the standard FlexHead®and SuperFlex"" A. Locate the center of the ceiling tile marking, align the offset Flexible Sprinkler Hose in accordance to NFPA 13, 13D, & screw with that marking for true center of the installation. Insert 13R for use in wet and dry sprinkler system.The Standard & one bracket leg at a time, applying a downward pressure on the SuperFlex'" Flexible sprinkler hoses are UL approved for Limited bracket leg and T-Bar. Screw the self tapping screw using a#2 flexibility and are intended for direct sprinkler connection. square head driver. Place the second leg on the T-Bar and repeat process. (Fig. 1) Fig,t ill ., 4t::;.$,,;ii.,:it..:„.. fI FlexHead* Standard Tall • j 2024T, 2036T, 2048T, 2060T, 2072T t- - .. / "•%,.. aa1 's 4 "`t::1 FlexHead* Standard Tall Elbow 2024ET, 2036ET, 2048ET, 2060ET, 2072ET FlexHead Flexible Hose Installation A.Apply Teflon®tape and pipe sealant to the 1"NPT thread. Install into branch outlet.Any direction is acceptable,ensure the hose ,.� is allowed at least one bend per installation to allow for seismic movement. (See Friction Loss Chart on page 3 for details.) e�� B.Tighten hose using the pipe drop section, never apply a wrench to the braided hose for installation.(Fig.2) SuperFlex" . 2036SF, 2048SF, 2072SF Fig.2 � ar The MPT bracket is set for 24"center of tile installation. (See back side for additional installation configurations) r it r .« , "Intended for use on ASTM C 635 intermediate or heavy duty ceilings ® ® r systems installed in accordance to ASTM C 636, APPROVED Do not wrench on braided hose 4 www.flexhead.com Secure the FlexHead Sprinkler Drop to Installation Complete MPT Bracket � �,�°r A. Maneuver the flexible sprinkler drop from the branch to the MPT y bracket. Review that the hose length, number of bends, and bend radius are applicable for the installation per NFPA guidelines. (See Corresponding hose technical data sheet for installation information.) ° ' B.The MPT bracket has an open hub for ease of installation. Open the hinge apparatus by turning the locking shaft 1/4 turn. Slide the flexible hose drop into the hub. Ensure the drop is vertical, and the SS Flexible` hose is not applying a substantial moment on the bracket r' causing sprinkler misalignment. Latch the hinge door close and adjust the sprinkler drop for desired ceiling height.Tightening the set screw till hand tight plus two full revolutions, (130 in-Ibs). J (Fig.3a and 3b) Installation Configuration C. Install desire sprinkler head, per the manufacturers installation instructions. i' t 1 Fig.3a ./ i L\ iL '" 'r 24"Tile— 24/4 ► Quarter Mark Position il em `'• =e Ufa i�2�IIi'l Gi�i� V / Ceiling Tile Installation 16"Tile — 16/2 Center Position A. The flexible sprinkler drop system with MPT Bracket is able to be installed prior to the ceiling tile installation, preventing the need for sprinkler contractor tile adjustment. '- B. For ease of tile installation, cut the largest sprinkler hole recommended by the manufacture.The largest hole that is still covered by the sprinkler escutcheon allows for an easier install C. Angle the tile at 45 degrees and push the tile through the hole and -� up above the ceiling T-bar, maneuver the tile and allow it to drop in the proper location. (Fig.4) 16' Metal Stud ,l'r� (Web Size > 5") i.\ Fig 4 Center Position" ".4.:' t t 4--- . t. Jr '". '4 m ./. t S,„ ... .1, Y -, x«r , ,. . it 14' 2"Wood Stud r,, Center Position` 1' ` 'i' U.S.and International Patent Pending: #6,123,154,#6,119,784,#6,752,218, #7,032,680,#6,488,097 'FM Approved,Installation has not been evaluated by UL 800.829.6975 20XXET with MPT-24BKT1 bracket has not been evaluated by UL. We invented the concept of flexible fire protection?"' INSTALLATION INSTRUCTIONS - MPO & ADO BRACKET Installation of FlexHead® Commercial Ceiling Flexible Sprinkler Drop System For use with FlexHead®hoses; 2024T, 2036T, 2048T, 2060T, 2072T 2024ET, 2036ET, 2048ET, 2060ET, 2072ET Y •jYl IJ J.. T-Bar Ceiling Grid Installation FlexHead'' Flexible Hose Installation The bracket is designed for use on ceiling grids conforming 1. Apply Teflon°tape and pipe sealant to the 1" NPT to ASTM C635. thread. Install into branch outlet. Any direction is 1. Locate the center of the ceiling tile marking, then align acceptable, ensure the hose is allowed at least one the screw hole for true center of tile installation. bend per installation to allow for seismic movement. 2. Clip the bracket on the T-Bar Ceiling Grid. 2, Tighten hose using the pipe drop section, never apply 3. Center of the leg section must be on the outside of a wrench to the braided hose for installation. the T-Bar(Fig. 1). 4. Secure each bracket leg to the T-Bar with #2 Head self Fig.2 k tapping screw. , 4. Fig.1 In - MPO Bracket Shown • : 19Nn• Do not wrench on braided hose 011 www.flexhead.com 3 Secure the FlexHead 4 Sprinkler Drop to Bracket Adjustment for Multiple Positions the Bracket 1. MPO Hub Adjustment- Remove the nut and screw 1. Maneuver the flexible sprinkler drop from the branch on the hub assembly. Slide out the tab and move to to the bracket. Review that the hose length, number desired position. Insert tab into square opening at of bends, and bend radius are applicable for the desired position and install screw from below. Install installation per NFPA guidelines. (See corresponding nut and tighten to hand tight plus one turn. hose technical data sheet for installation information on pages 10-11.) 2. The bracket has an open hub for ease of installation. Open the hinge apparatus by turning the locking shaft Ya turn. Slide the flexible hose into the hub. Ensure the I drop is vertical and the SS Flexible®hose is not applying ,,, • r a substantial moment on the bracket, causing sprinkler C �'41 f misalignment Latch the hinge door close and adjust "' " the sprinkler drop for desired ceiling height. Tightening the set screw till hand tight plus 1 full revolution, (100 in-Ibs). 3. Install desired sprinkler head per the manufacturer's \ installation instructions. JJ1r7� � h :; 2. ADO Hub Adjustment- Loosen screw and nut on each side of the hub, do not remove. Slide the hub to , , . i th/ e hdtesirtehd position h aanndd e ghpttightenlu screw e tounr neach side. t r it ' rP s Fig.3 ., 11, MPO Bracket Shown ' - U.S. and International Patent Pending: #6,123,154, __ ,; #6,119,784, #6,752,218, #7,032,680, #6,488,097 s:;. P1111 We invented the concept of flexible fire protections"' NFPA 13 CODE LANGUAGE & SEISMIC QUALIFICATION NFPA 13 STANDARD FOR INSTALLATION OF SPRINKLER SYSTEMS 2016 EDITION 9,2.1.3.3 Flexible®Sprinkler Hose Fittings. 9.2.1.3.3.1 Listed flexible sprinkler hose fittings and their anchoring components intended for use in installations connecting the sprinkler system piping to sprinklers shall be installed in accordance with the requirements of the listing, including any installation instructions. 9,2.1,3.3.2 When installed and supported by suspended ceilings, the ceiling shall meet ASTM C 635, Standard Specification for the Manufacture, Performance, and Testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings, and shall be installed in accordance with ASTM C 636, Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-In Panels. 9.2.1.3.3.3 When flexible sprinkler hose fittings exceed 6 ft(1.83 m) in length and are supported by a suspended ceiling in accordance with 9.2.1.3.3.2, a hanger(s)attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft. (1.83 m). 9.2.1,3.3.4 Where flexible sprinkler hose fittings are used to connect sprinklers to branch lines in suspended ceilings, a label limiting relocation of the sprinkler shall be provided on the anchoring component. A. 9.2.1.3.3.3 The committee evaluation of flexible sprinkler hose fittings supported by suspended ceilings was based on a comparison of the weight of a 6 ft, 1 in (1.8 m)diameter Schedule 40 water-filled unsupported armover weighing approximately 13 lb(5.9 kg)to the weight of a 6 ft, 1 in, (1.8 m)diameter water-filled flexible hose fitting weighing approximately 9 lb(4.1 kg). The information provided to the committee showed that the maximum load shed to the suspended ceiling by the flexible hose fitting was approximately 6 lb(2.7 kg)and that a suspended ceiling meeting ASTM C 635, Standard Specification for the Manufacture, Performance, and Testing of Metal Suspension Systems of Acoustical Tile and Lay-In Panel Ceilings, and installed in accordance with ASTM C 636, Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-In Panels, can substantially support that load. In addition, the supporting material showed that the flexible hose connection can be attached to the suspended ceilings because it allow the necessary deflections under seismic conditions. A,9.2.1,3,3.4 An example of language for the label is as follows: CAUTION: DO NOT REMOVE THIS LABEL, Relocation of this device should only be performed by qualified and/or licensed individuals that are aware of the original system design criteria, hydraulic criteria, sprinkler head listing parameters, and knowledge of the state and local codes including NFPA 13 installation standards. Relocation of the device without this knowledge could adversely affect the performance of this fire protection and life safety system. Reproduced with permission from NFPA 13-2016, Standard for the Installation of Sprinkler Systems, Copyright© 2015, National Fire Protection Association, This reprinted material is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. www.flexhead.com FLEXHEAD° SATISFIES SEISMIC CODE REQUIREMENTS The FlexHead®hose allows the head to move Typically, each unit consists of a threaded pipe in any direction during a seismic event without nipple for connecting to the main or branch causing damage to the sprinkler system. feeder • rreducing f tting thate rose in standard lengths,the sprinkler head attaches ASV:: +�•+•ti• ••••4� 4�'� 4 �• 1" /oAriSb 4. to, and a mounting bracket. ;.,.*„ Mounting _ Bracket —L—_ alt e na NNW 1 Ceiling Tile FlexHead® Industries recently satisfactorily completed full-scale seismic qualification testing at the Structural Engineering Earthquake Simulation Laboratory located at the State University of New York at Buffalo. Tests were conducted using the International Code Council(ICC)acceptance criteria"ICC-ES AC-156 Seismic Qualification Testing of Nonstructural Components". • More than 90% of the states in the U.S. are adopting the • In Seismic Design Categories D, E&F, suspended International Building Code (IBC)that address, among ceilings are to be designed and installed in accordance other things, the installation of fire sprinkler systems in with CISCA recommendations for seismic Zones 3 and 4 seismic zones. with some additional requirements. Except where rigid •The latest version of the IBC defers to ASCE 7 for the braces are used to limit lateral deflections, sprinkler heads sprinkler/ceiling design in Seismic Design Categories and other penetrations shall have a 2-inch oversized ring, 9SDC)C and D, E&F. sleeve, or adapter through the ceiling to allow for free movement of at least 1 inch of ceiling movement in all • In Seismic Design Category C, suspended ceilings are to horizontal directions. be designed and installed in accordance with Ceilings& Interior Systems Construction Association (CISCA) • Flexible sprinkler connection provide characteristics that recommendations for Zones 0-2; and sprinkler heads exceed the most stringent seismic code requirements, and other penetrations shall have a minimum of/ inch The flexibility of the hose allows the head to move with clearance on all sides, the ceiling in any direction during a seismic event without causing damage to the sprinkler system. 800.829.6975 C We invented the concept of flexible fire protections"' FRICTION LOSS DATA & SPECIFICATIONS Maximum Max Rated Minimum Bend Number of Equivalent Length of tin.Diameter Schedule 40 Pipe(Ft) Pressure Outlet Hose Radius 4 9 Model Orifice Assembly 90 Bends PSI(I(pa) Number Size Length (FM) (EMI (FM) (FM) (FM) (FM) UL • FM in(cm) m(mm) FM UL UL FM (UL) 56k-factor 80k-factor 112k-factor 14.0k-factor 16.8k-factor 22.4k-factor PSI PSI in(tom) in(mml- Ft(m) Ft(m) Ft(m) Ft(m) Ft(m) Ft(m) Ft(m) (Kpa) ) (KPa) SUPERFLEX"1"INTERNAL DIAMETER(111.1 HOSE SERIES 2036SF-50 36(914) 5 2 30(91) 16.2(4.9) 16-915.1) 11.5(3.51 - - 2048SF-50 � 48112191 7 2 8 3 47114.3) 28.7(8.7) 293(89) 15.4(4.7) - - - 175 175 (1.27) 1178) 150.8) (1205) (12051 20725F-50 72(1828) 12 4 71121.61 539(16.4) 54.3116.5) 23.217) - - - 2036SF-75 36(914) 5 2 29(8.8) - 21.516.5) 21.616.51 21.8(6.6) 22(6.7) - 2048SF-75 (1 90) 48(1219) 1178) (50.81 8 3 44113.41 - 305(92) 30.6(9.3) 31.1(9.41 30.8(9.31 - (11205)75 (112051 2072SF-75 72(1828) 12 4 70121.3) - 48.5114.71 46.8114.81 49.9115.2) 48.6114.8) - FLEXHEAD'r STANDARD/TALL COMMERCIAL.1"INTERNAL DIAMETER 11 D_I HOSE SERIES 20241-50 24(610) 3 1 11 18 4(5.61 7 7(2 3) 7 612.3) - - - 20361-50 361914) 3 2 16 26.6(8.1) 11 5(3 5) 11.5(3.5) - - - 2048T-50 (127) 4811219) I (200) (76.2) 4 3 24 30.3(9.2) 15314.6) _ 15.4(4.7) - - - (1205) (11205) 2060T-50 60(1524) 4 4 29 35.8(10.91 19.1(5.8) 19.315.8) - 20721-50 72(18281 4 4 35 45.5(13.91 23.0(7) 23.2(7) - - - 20241-75 24(6101 3 1 12 - - - 14.7(4.51 7-1(2.1) - 20367-75 36(914) 3 2 1 R - 21.5(6.5) 21.6(6.6) 21.8(66I 10.9(3.3) - 75 175 2048T-75 (1,90) 4811219) (200) (762) 4 3 23 - 30.519.3) 30.619.3) 2918.8) 14.814.5) - (112 5) 11205) 20601-75 60(1524) 4 4 29 - 39.5(12) 39.61121 36.1(11) 18.7(5.6) - 2072T-75 72(1828) 4 4 'I 32 - 48-51147) 48.0114.9) 432(13.1) 22.616.8) - FLEXHEAD®TALL ELBOW SERIES 202402.50 24(6101 3 1 19 26.4(8-01 6-8(2) 7.4(2 2) - - - 2036E7 50 361914) 3 2 I 23 i 30.1(9.1) 11 8(3 61 12.5(3.8) - - - iln2048ET50 (127) 75 4811219) 8(2001 (76.2) 4 3 27 33.8(10.31 16 17.5133) - (11205)75 (11205) 2060E7-50 60(1524) 4 4 : 32 1 37.5(11.4) 21 9(6 6) '. 22.7(6.9) - - - 2072ET-50 72118281 4 4 35 412112.51 27.018.2) 27.818.41 - - - 2024E7-75 2416101 3 1 16 - -- - 14.7(4.51 82(25) - 2036E4-75 36(914) 3 2 23 - 252(771% .. 26(7.9) ', 21.8(6.6) 13(3.6) - 2048E475 (190) 48(12191 _ )200) (76.2) 4 3 23 - 32.9(10) 331101 29(8.81 17.815.4) - (11205)75 1112051 2060ET75 60(1524) 4 4 1 29 I - 406(1231 40(12.1) ( 36.1(11.0) 22.6(6.8) - 2072E4-75 ', 72(1828) 4 4 32 - 48.5(147) 47114.3) 432(13.1) 27.518.31 FLEXHEAD®STANDARD ELBOW 2024E-50 24(610) 3 1 19 26.4(8.0) -- - - - 2036E 50 '.. 36(9141 I 3 '.. 2 23 i 30.1(9.2) 1 - - - - - 2048E 50 48(1219) 8 3 4 3 27 33.8110.3) - -. _. 175 175 (1.27) 12001 (76.2) (1205) (1205) 2060E-50 60(1524) 4 4 ! 32 I 37.5(11.4) - - 2072E-50 72(1828) 4 4 35 41.2(12.6) - - - - - 2024E-75 24(6101 3 1 18 - 14.7(4.5) - - - - 2036E-75 36(914) 3 2 23 i - 21 8(6.6) '.. -. - - - 2048E-75 VI48(1219) 6 3 4 3 23 - 29.018.81 - - _.. _ 175 175 (1901 1200) (76.2) (12051 (1205) 2060E75 ', 60(1524) 4 I 4 29 ',.. - 1 36.1111.01 '.. - - '. - - 2372E-75 72(1828) 4 4 32 - 432(13.2) - - - Chart continued on the next page Notes: •Model Numbers:The"SF"designates SuperFlex'"Hose series.The'50"designates Nz"Outlet Hose series.The"75"designates 3"Outlet Hose series.Inlet size 1". •Model Numbers:The"T"designates tall drops length hose series. The'ET"designates tall elbow drop hose series. The"E"designates elbow drop hose series.The"H" designates high pressure 300PSI working pressure hose series.THE HE designates high pressure 300PSI elbow hose series.The"F"designates high flow rate using 1 39 L.D. hose series.The"OPS"designates dry pendent system hose series. •Max ambient temperature rating on all model numbers are 300 F(148 C) •Equivalent lengths are shown with maximum number of 90°bends at the minimum bend radius per agency. 2-45°or 3-30°bends equal 1-90°bend.Different values were obtained by FM and UL due to the difference in minimum bend radius testing protocol and calculation methods. Please see individual standards for more information relative to Friction Loss(equivalent length of pipe) •All hoses require a minimum of one bend for installation. Bend radius tool available for"T"hose,"SF"hose does not require bend radius tool. •20XX,SuperFlex° Hose,is UL Listed with MPT-24-BKT1 Bracket with largest k-factor of 16.8. •FM Equivalent length calculation includes Sprinkler Head fiction loss.UL equivalent length calculation include the hose only. •FlexHead products are intended for use in hydraulically designed wet,pre-action,deluge or dry pendent sprinkler connections per NFPA 13, 13R and 130 guidelines. •See listing(s)approval agency for latest approval details. 1111 www"fiexhead"com FRICTION LOSS DATA & SPECIFICATIONS fcont'd) Maximum Max Rated Pressure Minimum Number of E uivalent Len th of tin.Diameter Schedule 40 Pie(Ft) Outlet Hose Bend Radius q 0 P PSI(Kpa) Model Orifice Assembly 90 Bends Number Size Length FM UL ' (FM) IFM) IFM) (FM) (FM) (FM) fn(cm in mm (UL) ( UL PSI FM PSI I ( ) in in UL FM 5.6k-factor 6.0k-factor 11.2k-factor ' 14.0k-factor 16.6k-factor 22.4k-factor Ft(m) (Kpa) (Kpa) (mm) (mm) i Ft(m) Ft(m) { Ft(m) Ft(m) Ft(m) Ft(m) FLEXHEAD®HIGH PRESSURE'!"INTERNAL DIAMETER(1.0.1 HOSE SERIES 2024H-50 241610) ..._.... 3 2 11 18 4(5.6) 7.7(2.3) 7.6(2.31 - - 2036H-50 36(914) 3 3 16 26.6(8.1) 11.5(3.5) 11.5(3.5) - ,:, - ,:, - 2048H 50 A 48112191 8 3 4 4 24 30.3(92) 15.3(4 6) 15-4(4.7) - 300 PSI 300 PSI (1 27) (2001 17621 12068Kpa) 120684a) 2060H-50 60(15241 4 4 29 35.8(10.91 19.1(5.81 19.3(5.81 - - 20721-I-50 72(18281 4 4 35 45.5113.91 23(71 23.2171 - - - 2024H-75 2416101 3 2 12 - 14.7(4.5) 14.7(4.51 14.7(4.5) 7.1(2.1) - 2036H 75 36(914) 3 3 18 - 21.8(6.61 j 21.6(6.6) 21.8(6.61 10.9(3.3) - 2048H 75 �" 48(12191 8 3 4 4 23 2918.8) 30.6(9.31 29(8,81 14.814.5) - 300 PSI 300 PSI (1.90) (200) 17621 12068Kpa) (2068Kpa) 2060H-75 60(15241 4 4 29 - 361(11.0) ! 39.6(12) 36.1111.0) 18.7(5.7) - 2072H-75 72(18281 4 4 32 43.2113.1) 48.6114.8) 43.2(131) 22.6(6 8) - FLEXHEAD5 HIGH PRESSURE ELBOW 2024HE-50 24(610) 3 ,i 2 19 14.7(4.51 6.8121 7A(22) - - - 2036HE-50 361914) 3 '.I 3 23 21.8(6.6) 11.8(3.6) 12.5(3.81 '': - - - 2048HE50 48(1219) 8 8 4 4 27 29.0(8.81 169(5.1) 17.6(53) - - 330 PSI 300 P51 1127) (2001 (7621 (2068Kpa) (2068Kpa1 206011E-50 ', 60(1524) 4 4 32 36.1(11) 21.9(6.6) 22.8(6.91 1 - - 2072HE-50 7211828) 4 4 35 43.2(13.1 27(8.2) 27.8(8.4) - - ' 202411E-75 241610) 3 2 18 - 14.7(4.5) - 14.7(4.5) 1 8.2(2.5) - 2036HE-75I 361914) 3 3 23 - 21.8(6.6) 2617.9) 21.8(6.6) 13(3.9) 2048HE-7534 48(1219) 8 3 4 4 23 - 29(8-8) 33(10) 29(8.81 17.8(54) _ 300 P51 300 PSI (1 90) (200) (76 2) (2068Kpa) 12068Kpal 2060HE 75 6011524) '. 4 4 29 - 36.1(11.0) ' 40(12.2) 36.1(11.01 22.6(6.8) ' - 2072HE-75 7211828/ 4 4 32 - 43.2(13.1) 47(14.31 43.2113-11 27-5(8-3) - FLEXHEADe DRY PENDENT SYSTEM 2024-0PS 2416101 - 1 - 18.4(5.61 7.7(2.31 7.6)2.31 - 7.1(2.1) 10.713.3) 2036-LIPS 36(914) - 2 26.6(8.11 11.512.3) 11.513.5) ; - ` 10.9(3.3) 15.1(4.6) 2048-DPS j254) 48(1219) )1801 - 3 - 30.3(9.21 15.3(3.5) 15.4(4.7) - 14.8(4.5) 21.5(6.5) - 112 5) 2060-DPS I 60(1524) 4 ' - 35.8(10.9) 19.115.8) 19.315.9) - 18.7(5.7) 1 25.317.7) :. 2072-DES ' 72118281 - 4 - 45.6(13.91 2317) 23.2(71 - 22.6(6.9) 26.918.11 1.25"INTERNAL DIAMETER(I.D.)HOSE SERIES 2036F-50 36(9141 - 1 - 4.1(1.2) 4.111.21 4.1(1.2) - - 2048F50 ': (127) 48(1219) (180) 2 5.4(1.6) 5.6(1.71 5.7(1.7) - - - - (1175 205j 2072F-50 72118281 - 4 - 8.0(2.41 8.6(2.6) 9.1(2.7) - - - 2036F-75 36(914) - 1 - - - - 3.4(1,01 ':. 3.4(1.011/2 7 2048F75 , 0501 48(1219) (180) - - 2 - ': - - ', - 4.8(1.5) ', 4.811.4) - - (112051 20726-75 72118281 - 4 - - - - 76(2.3) 7-6(231 - 2036F-100 36(914) 2 - - - - - - 34(1.0) 1 2048F-100 ., (1541 7 48{7219) (1so) - 3 - - - - 4.811.4) - 75 (11205) 2072F-100 72(1828) - 4 - - - - - - 7.6(2.3) Notes: •Model Numbers:The"SF"designates SuperFlex'"Hose series.The"50"designates'h°Outlet Hose series.The"75"designates 3"Outlet Hose series,Inlet size 1". •Model Numbers:The"T"designates tall drops length hose series. The"ET"designates tall elbow drop hose series.The"E°designates elbow drop hose series.The"H"designates high pressure 300PSI working pressure hose series.THE"HE"designates high pressure 300P51 elbow hose series.The"F"designates high flow rate using 1-1/4 I.D.hose series.The"DPS'designates dry pendent system hose series. •Max ambient temperature rating on all model numbers are 300 F(148 C) •Equivalent lengths are shown with maximum number of 90°bends at the minimum bend radius per agency.2-45°or 3-30°bends equal 1-90°bend.Different values were obtained by FM and UL due to the difference in minimum bend radius testing protocol and calculation methods.Please see individual standards for more information relative to Friction Loss(equivalent length of pipe) •All hoses require a minimum of one bend for installation. Bend radius tool available for"T"hose,"SF"hose does not require bend radius tool. •20XX,SuperFlex'"Hose,is UL Listed with MPT-24-BKT1 Bracket with largest k-factor of 16.8. •FM Equivalent length calculation includes Sprinkler Head friction loss.UL equivalent length calculation include the hose only. •F1esHead products are intended for use in hydraulically designed wet,pre-action,deluge or dry pendent sprinkler connections per NFPA 13, 13R and 13D guidelines. •See listing(s)approval agency for latest approval details. 800,829.6975 E We invented the concept of flexible fire protectionTM FLEXHEAD° CEILING DETAIL , FlexHead® Suspended Ceiling Detail FlexHead" MPO24BKT2 FlexHead ' r Bracket } MPT24BKT1 Bracket :'1 �' �` V —The lr1 I _ F_".-- 1 p. 'Allows for bracket installation without pre-installing the ceiling the FlexHead® Sheetrock Ceiling Detail FlexHead"' MPO24BKT2 FlexHead" Bracket 7---lingiii;:iilititglantialle MPT24BKT1 Bracket/ ?.;f ; iigli :nig§§§§§;. , : 1: Ill , Each FM approved and UL listed unit is ready to install, pressure- and leak-tested, and comes complete with a flexible stainless steel hose and mounting bracket with adjustable hub. FlexHead ' Standard Hose 3" Bend Radius FlexHead" Standard Hose Shown per UL Guidelines (2 Bends Shown) with 3 Bends 71 . t . �� I! 1nn.n _a ".. 2 3 7••••••• I ,,,,. (-----...„ y4 fa- ` W' --% , i- X \,.., , • M . . • '- A 1,1Hy _ r `�T.!.l `1 p>. lille PI ' ~,y,\ _ .";wry`, _.. Notes: See SuperFlex"bend radius information on page 9.SuperFlex"2"bend radius eliminates the need to count or measure the bends. Ili800,829,6975 www.flexhead.com ': FLEXHEAD® CEILING DETAIL , REGULAR 1"HOSE MODEL; REGULAR 1"HOSE MODEL; ELBOW 1"HOSE MODEL; REGULAR 1-1/4"HOSE MODEL: 20XXSF&20XXT SERIES 20XXH SERIES 20XXE,20XXHE,& OXXET SERIES 20XXF SERIES 1 I"NPT. lir 1'NPT I'NPT I Sin CUT GROOVE 1I-1/4 CUPT T ROOEAD OR OPTION WITH 3in 3in Sin l-I/a^CUT GROOVE 2OXXSf I_ L OPTION AVAILABLE L±20mm L±20mm L±20}mm L±20mm .,,c_ 1 1 5 I/7 NPT OR 3/4 NPT 1 FEMALE THREAD _ 1.Sin 01.315in!r� ) 4.50. '- 4.50in „D„ 6.3in SEE CHART .2 f T v_ .` 0 1315in 01.66in f?NP I T OR 3/4"NPT 1/7 NPT.3/C NPT. FEMALE THREAD OR I'NPT FEMALE THREAD 0 1.315in 1/7 NPT OR 3/4^NPT FEMALE THREAD MODEL# "Hose Assembly(L)Length Inches(mm)" "Drop""0""Size(Inches)" 2024E/2024HE 24(610) 2036E/2036HE 36(914) 2048E/2048HE 48(1219) 1.5,3.0,&4.0 2060E/2060HE 60(1524) 2072E/2072HE 72(1828) 2024ET 24(610) 2036ET 36(914) 2048ET 48(1219) 671 2060ET 60(1524) 2072ET 72(1928) C • We invented the concept of flexible fire protection' BRACKET SPECIFICATION SHEET Multiport Design (For use with T-bar and Adjustable Design (For use with T-bar, Metal Metal Stud Applications) Stud and Chicago Grid Applications): standard sizes are 16", 24", 30" and 48" long Model # MP024BKT2 Model # AD016BKT3, AD024BKT3, ADO3OBKT3, AD048BKT3 OVERALL LENGTHS 16".20"771F6.P PATTERN--w.-- OR 24. -. - 11--- - . S milii_ - _ _ ; �� —i �i.,��; . a \ m . � � I _ � � ;� q a s B r.l&r,OR 22.r—N Lm CORP6: ADp16: 6a-2.75 *DO2Hf I6%)-3 . ,—OPEN HUB DESIGN:UHO-3° 3/$'-16 NUT�\\ [L � 3/$'-16.L=LQ'BOLT- 1,14 in t _._ 77-J Multi-Position Tall Bracket(For use with T-bar, Wood and Metal Studs): 24"standard size collapsible to 14.5" and 16" long. Model # MPT24BKT1 `o ( X� � (p 24in t fi [60Smm 0'. d v t .>'r loin '' . 1406mm 14.SIn [366.3mm 1 I., �'-1 f 4www.flexhead.com Pwo,,()�i '�1CYII �� C aria--.e�sm�q,t 24",36",48",60", 72"hose lengths, 24",36",48",60", 72" hose lengths. Rated working pressure 175psi,optional 300psi. Rated working pressure 175psi,optional 300psi. Straight model, Elbow model. Standard 1"I.D.,optional 11 d' I.D. SuperFlex" Hose Lengths:36",48"and 72" . 'i,�, .. gar ,,,�' r € r y 24" Multiport Bracket for T-bar Grid or Metal 16"/24"/30"/48"Adjustable Bracket for Stud applications. T-bar Grid,Chicago Grid or Metal Stud applications. Model #: MP024BKT2 Model #s:AD016BKT3/AD024BKT3/AD030BKT3/ ADO48BKT3 � #ass:si+rk+iis iYM1iu1 e4 dd3d-^' 1'""� ! Hat Channel Bracket System for Metal Stud or 24" Multi-Position Tall Bracket Hat Channel applications. Model #: MPT24BKT1 Model #:ADO24BKT3 with BKT-HTA 4111 • Bracket for Confined Space Armstrong"TechZone Ceiling Bracket Dry Pendent System for Freezer and applications having a concrete for use with Armstrong TechZone Cold Storage applications deck above the ceiling. Ceiling systems. Model #: 20XX-DPS-UH03 Model #: UH0-3 Available in 6"long. Model #:SP06TZBKT2 800.829.6975 ''i- We invented the concept of flexible fire protectionTM y#, FLEXIBLE SPRINKLER HOSE FITTINGS USE EXAMPLES - "mar, Aotit- �- . � ' APPROVED 4 F /! •VV`. b i UL i" z• y 4,04t.; 4--f-L- t Ili ' '''' ' - — ):. tp ,, / �,.a Suspended Ceilings SuperFlex" Exhaust Ducts y' (EEx-Ea. ` :• APPROVED t' A ' APPROVED f i i AA_ - •-.,_ .. i I Institutional Cold Storage and Freezer Cleanroom Ceilings Applications Flexible Sprinkler Hose Fittings were developed to satisfy specific needs of the industry, save the industry millions in losses, provide superior seismic protection and promote the installation of sprinklers. They have been evaluated for use by both Underwriters Laboratory and FM approvals and are tested to approval standards that were independently developed by the testing laboratories. The first listing for a Flexible Sprinkler Hose Fitting was in 1990. www.flexhead.com WARRANTY FLEXHEAD® PRODUCTS LIMITED WARRANTY Flexhead Industries, Inc.warrants that its products will be free from defects in materials and workmanship under normal conditions of use and service when properly installed for a period of one year from date of sale. Our obligation under this warranty is limited to repairing or replacing any product that is returned to us with transportation charges prepaid within one year after the date of original sale and that our examination shows to our satisfaction to have been defective in materials or workmanship under normal conditions of use and service.The decision as to whether to repair or to replace any product shall be made by us, and any repair shall be made at our facility. Notwithstanding the foregoing,the following are specifically excluded from the coverage of this warranty: (a)Any product not manufactured by Flexhead Industries, Inc., including any sprinkler head(s)installed with or attached to a Flexhead Industries, Inc. product, provided, however, Flexhead Industries Inc. hereby assigns the right to enforce any original manufacturer's warranty of such product to the original purchaser of the Flexhead Industries, Inc. product(s). For the avoidance of doubt, Flexhead Industries, Inc.does not manufacture sprinkler heads and,therefore,does not warrant any such products. (b)defects resulting from ordinary wear and tear, including,without limitation,the replacement of the so-called poly bag components of any Flexhead Industries, Inc. product (c)products that have been altered in any manner by the buyer or by anyone other than Flexhead Industries, Inc. (d) products that have been subjected to misuse,abusive use, or damage by accident or casualty (e)products that have been installed or used in a manner contrary to our specifications, instructions or recommendation (f) products that have been installed or used in a manner that is not in compliance with all applicable requirements of any code, law, regulation or rule of any federal, state or local governmental or industry authority; and (g)products that have not been inspected and maintained in accordance with our specifications, instructions or recommendations, including,without limitation,our recommendations as to following the inspection and maintenance standards published by Factory Mutual Research Corporation(FMRC)and the National Fire Protection Association (NFPA); and (h)products that have been affected by Microbiologically Influenced Corrosion(MIC). This warranty is not assignable and shall benefit only the original purchaser of a Flexhead Industries, Inc. product. If any provision hereof or any portion of any provision shall be held invalid,the remainder of this Limited Warranty shall not be affected thereby, and all provisions of this Limited Warranty shall remain valid and in full force and effect to the fullest extent permitted by law.THIS WARRANTY IS IN LIEU OF ALL IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO,WARRANTIES OF MERCHANTABILITY AND WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE. NOTWITHSTANDING ANY PROVISION TO THE CONTRARY HEREIN OR ANY APPLICABLE LAW TO THE CONTRARY, IN NO EVENT SHALL FLEXHEAD INDUSTRIES, INC. BE LIABLE FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES UNDER ANY CIRCUMSTANCES WHATSOEVER,WHETHER ARISING FROM ANY BREACH OF THIS LIMITED WARRANTY OR OTHERWISE ARISING FROM OR IN CONNECTION WITH THE USE OR OPERATION OF, OR ANY DEFECT IN,ANY FLEXHEAD INDUSTRIES, INC. PRODUCT, OR OTHERWISE.The risk of damages from any breach of warranty with respect to injury to any person will be born by the purchaser of Flexhead Industries, Inc. product. 800.829.6975 C We invented the concept of flexible fire protection' NOTES www.flexhead.com NOTES 800.829,6975 E #(.strum$tntNvs¢t"v6YS t v4Pt x+i°&#Ysn S.Mk.9 M+tda4'tt&t Aaen••u�<#..m'-ta*M:.ry.YrAY 56 Lowland Street Holliston, MA 01746 PRONE/ 508-893-9596 TOLL FREE/ 800-829-6975 www.flexhead.com G LOK' /FIN © Cat awissa. l44p ,ANVIL EPS° tP 411) l': ai- I N T E R N A T I O N A L ©2018 Anvil International.All rights reserved.FXH-L-4005-1803