• 2201-03ti O RECEIVED SEP , 4F;: BMANHESTER CITY OFTIGARD BUILDING DIVISION TECHNOLOGY SYSTEMS EQUIPMENT SUBMITTAL for Courtyard by Marriott - Pool Conversion 15686 SW Sequoia Pkwy, Tigard, OR 97224 Fire Alarm System AdditionlAlteration submitted by GB Manchester Inc CCB 202097 MODEL # DESCRIPTION MFG iO500GD FIRE ALARM CONTROL PANEL(EXISTING) EST G1AVWF HORN-STROBE,WALL,WHITE EST GCVWF STROBE,WALL,WHITE EST GCAVWF HORN-STROBE, CEILING,WHITE EST GCVWF STROBE,CEILING,WHITE EST 6000 NE 88th St,Vancouver, WA. 98665 Portland 503.287.1112 Vancouver 360.816.0484 Toll Free 877.816.0484 THIS PAGE INTENTIONALLY LEFT BLANK ** EXISTING ** Small Building Fire Alam1 Solutions E Life Safety & Communications MOO i0500 Intelligent men MIND NNW - f Life Safety System woo °°° .LOG FDNY COA 6020 ii 7165-1657. 0244 S3000 Overview Features The EST i0500 intelligent life safety system offers the power of • Comes standard with one loop(expandable to two)that high-end intelligent processing in a configuration that delivers an supports up to 250(expandable to 500)intelligent devices: uncomplicated solution for small to mid-sized applications.With each i0500 loop supports up to 125 detectors and up to 125 intelligent detection,electronic addressing, automatic device map- modules. ping, optional Ethernet®connectivity,and a full line of easily-con- • Supports Signature Series intelligent modules and detectors figured option cards and modules,this flexible system offers offers versatility that benefits building owners and contractors alike. • Combines the Signature intelligent releasing module with Signature multisensor detectors for reliable suppression The i0500 provides one Class A or Class B analog device loop • Four Class B NACs or two Class A NACs. that supports up to 250 device addresses.A second 250-point loop may be added to the i0500 to expand total system capacity • Form C contacts for alarm and trouble, Form A for supervisory to up to 500 device addresses.The panel includes four NACs that • Electronic addressing with automatic device mapping may be wired for either Class A or Class B operation. • Optional Ethemet port for diagnostics, programming and a The i0500 supports a wide range of accessories and related variety of system reports equipment,including: • Two programmable switches with LEDs and custom labeling • Signature Series intelligent modules,detectors, and bases • Supports Genesis horn silence over two wires and UL • R-Series remote annunciators 1971-compliant strobe synchronization • option cards that expand system capacity and extend system • Supports up to eight serial annunciators,(LCD, LED-only,and capabilities graphic interface). • Listed for releasing applications using SIGA-REL • 1,000 event panel history log • Fully integrated CO detection using Signature Series 2 detec- • Can use existing wiring for most retrofit applications tors with or w/o audible signaling • Upload/download remotely or locally • Two-level maintenance alert reporting • Pre-alarm and alarm verification by point • Adjustable detector sensitivity • 4 x 20 character backlit LCD display • Optional earthquake hardening:OSHPD seismic pre-approval for component Importance Factor 1.5 Page 1 ei 10 85005-0130 Issue 7.1 ** EXISTING ** Application Operation The i0500 life safetysystem is apowerful intelligent solution for The frontpanelprovides ii� ys 9 Him] KID; small to mid-sized buildings.Advanced analog technology delivers an easy-to-use operator's Him. I .1i. the benefits of flexible system installation,while a clean and easy- interface, as well as all Kj� —. ,f I lm to-operatate user interface makes panel operation and system the necessary controls for timm v; HIS a" ," ® IH.I maintenance quick and intuitive. front panel programming. RR a of KI- A large back-lit 80-char- HIS, ( I ®i l..� The smart choice acter LCD displays ( I[1a® Kim Signature Series electronic addressing eliminates the tedium of system status,event {1umm woo ({ice settingdi switches and automatic device mapping ensures that details,and programming ti��. OO© Ig i� P PP 9 K�a_ D® ii� each device resides on the system at its correct location. Mean- prompts. Large tactile tint 000 i.{Ioomm while, innovative programming allows the designer to customize control buttons are easy K C C S'' l'a the system to precisely suit the needs of the building owner. to see in low light condi- tions,and bright multi-color LEDs offer at-a-glance status indica- Flexibility built right in tion. Two fully-programmable front panel switch/LED combinations pro- vide an added measure of flexibility.Their slide-in labels take the mystery out of custom applications,and present a clean finished Control buttons appearance. Button Description , Reset Perfect for retrofits Initiates a system reset. The i0500 is particularly well-suited to retrofit applications.All ACK/Panel Silences the panel and remote annunciators during Silence active trouble,supervisory,or alarm event and connections are made over standard wiring—no shielded cable acknowledges new event activations. required.This means that in most situations existingwiringcan .__ q Signal Silence Alarm mode:Silences active notification appliances. be used to upgrade a legacy control panel to i0500 technology Pressing Signal Silence a second time turns NACs pack without the expense or disruption of rewiring the entire building. on. Drill Initiates a drill confirmation.Pressing drill a second time Signals with a difference turns off the drill function. 10500 NACs are configurable to fully support the advanced signal- Remote Dialer: Disables or enables dialer ing technology of Edwards Genesis and Enhanced Integrity notifi- Disconnect Dialer set to modem only:Disables or enables the cation appliances.These devices offer precision synchronization of common alarm relay strobes to UL 1971 standards. For Genesis devices,enabling this Let arrow Display mode:Moves the cursor to the left. feature allows connected horns to be silenced while strobes on Menu mode:Toggles between programming selections. the same two-wire circuit continue to flash until thepanel is reset. v s Right arrow Display mode:Moves the cursor to the right. Menu mode:Retrieves a programming option's sub Clear-cut remote annunciation menu and toggles between a programming option's Remote annunciation is a strong suit of the i0500. Up to eight an- selections 9 Menu mode:Moves the cursor up. nunciators can be installed on a single system.Compatible annun- Up arrow Display mode:Advances to the previous event. ciators include a range of LED and LCD models that provide zone or point annunciation,as well as common control capabilities. Down arrow Display mode:Advances to the next event. Menu mode:Moves the cursor down. The i0500 also supports graphic annunciation with optional Enter Display mode:Displays selected event details. graphic annunciator interface modules.Each interface provides Menu mode:Retrieves a programming option's sub common control, indicators,and LED drivers. Consult the Order- menu or jumps to the Save function in the menu. ing Information section for details. Entry mode:Enters the selected data into the system. Cancel Display mode:Exits the detailed information display. A complete line of accessories Menu mode:Exits the current menu level. Entry mode:Clears the current entry. The i0500 life safety system is supported by a complete line of Menu Display mode:Enters the menu mode intelligent detectors, modules and related equipment.Consult the Menu mode:Exits menu mode Ordering Information section for details. Space Enters a space,such as a space between words. Alphanumeric Entry mode:Pressing a button once enters the number keypad on the button.Pressing the button twice enters the secondary value. Programmable These buttons can be programmed to control outputs, buttons disable devices or unlatch system outputs.The buttons can be labeled with a slip-in insert. Page 2 of 10 85005-0130 Issue 7.1 ** EXISTIN ** - System LEDs nel Operation Options LED Description Language English or French Alarm Red LED.On steady when there is an active Marketplace U.S.or Canada alarm AC fail delay Off:Off-premise notification of an AC power failure Trouble Yellow LED. Flashes when there is a fault on a is immediate. monitored circuit or system component,or when a 1 to 15 hours:Delays the off-premise notification of circuit is disabled. an AC power failure by the time period selected. Sup Yellow LED On steady when there is an active Zone resound On:NACs resound each time a device in the zone supervisory event. goes into alarm even if they were silenced Off:Inhibits the NACs from turning on again(after AC Power Green LED. On when the panel has AC power. they were silenced)when a second device in the Disable Yellow LED. Double-flashes when there is a dis- zone goes into alarm. abled circuit, alarm relay,or remote annunciator. Reset inhibit after Off.Panel reset is operational immediately. Ground Yellow LED.On steady during an active ground fault. NACs turn on 1 minute:Panel reset is inhibited for one minute. Fault Auto signal Off:Allows immediate silencing of signals from an Test Yellow LED. Hashes when performing an audible silence off-normal condition using the Signal Silence button walk test.Steady indicates a silent test. 5 to 30 minutes:Delays the silencing of signals from an off-normal condition by disabling the Signal Monitor Yellow LED. On steady when there is an active Silence button for the time period selected. monitor event Day start Start time for daytime sensitivity Service Yellow LED. Indicates that detector needs servicing. Night start Start time for nighttime sensitivity Detector Date U.S.:MM/DD/YYYY,Canada:DD/MM/YYYY Signal Yellow LED.On steady indicates that NAG circuits Sounder Base Six configuration settings Silence are turned off but the panel is still in alarm. Mapping Disabled:Device mapping is not available Remote Yellow LED.On steady indicates that the dialer Enabled:Device mapping is available Disconnect is disabled or that the alarm relay is enabled or LCD banner Banner text for line one and line two.Each line is disabled when the dialer is set to modem only. capable of up to 20 characters. Drill Yellow LED. Indicates that the panel is in drill. Event notification Zone:When a device is a member of a zone,only i Reset Yellow LED. Indicates that the panel is resetting. the zone information is sent to the LCD display, LEDs,printer,and dialer. Panel Yellow LED. Indicates that the panel has been Zone/device:Zone information is sent to the LCD Silence silenced during an active trouble, supervisory, or display and LEDs. Device information is sent to the alarm event and indicates that new event activa- printer and dialer. tions have been acknowledged. Device:Only device information is reported. User Keys Yellow LED. Programmable. Programming Dimensions i0500 life safety systems are simple to set up,yet also offer ad- Surface mounting holes vanced programming features that put these small building panels 1-D2-01 D3 into a class of their own.The auto programming feature quickly — gets the panel operational using factory default settings. Basic ®°• 0 II •0 ° zone and point settings can be programmed easily through the ° _ ° A front panel interface,so the system is up and running in no time. II For more advanced system configuration and correlation groups • - t programming, i0500 systems interface to a PC running compat- ible i0-CU software.This option offers full system configuration — 0 - in the familiar Windows®operating environment.Connection is 7 typically made to a laptop through the panel's optional RS-232 °•-1, D1 ° D4 t ll communications port,which can also be used to connect a sys- ® N tern printer. 0 0 0 w Among the many innovative features of i0500 control panels is the aEi optional network card.This module provides a standard 10/100 ' ® : Base T Ethernet®network connection that permits access to the ° Surface mounting holes control panel from any remote location with the correct commu- nications protocols.The connection can be used to download to the panel from the i0-CU,or upload and view system reports I D6 • using the i0-CU. Ir. • D5 ► Available system reports include: • Correlation groups • Device details Panel dimensions,in(cm) • Device maintenance • History Model D1* D2 D3 D4 D5* ' D6 • • • Internal status • System configuration 0500 28.0 3.85 9.0 22.0 15.75 10.25 • System status • Walk test I (71.1) (9.8) (22.8) (55.8) (40.0) (26.0) • Dialer • CO runtime "Add 1-1/2 in. (3.81 cm)to D1 and D5 dimensions for trim kit. Page 3 of 10 85005-0130 Issue 7.1 Wiring & Configuration ** EXISTING ** Notification appliance circuits(T82) Signature Device loop 10500 control panels come equipped with four notification ap- The system provides one device loop circuit with a total capacity pliance circuits. Each circuit can be individually configured for of 125 detectors and 125 module addresses.The loop circuit is continuous,temporal,synchronized,latching,and coded output. supervised for opens,shorts,and grounds. Circuit specifications The Signature Loop Controller uses broadcast polling and ad- ' Circuit Type 4 Class B or 2 Class A,2.5 amps each vanced communications formats to regularly check the entire Voltage 24 VFWR device circuit for anomalies. If a change of state is detected at the Current 6.0 A total,2.5 A max.per circuit at 120/230 VAC 60 Hz circuit level,the Loop Controller then uses a direct address search 5.0 A total at 230VAC 50 Hz,2.5 A max.per circuit to find the reporting device.This two-staged technique ensures Impedance 26 0 total,0.35 pF max that only new information is transmitted,thus allowing for a re- EOLR 15 K 0,,1 W duced baud rate while still achieving nearly instant device reporting. Circuit specifications Device loops 1 loop,expandable to 2,Class A or B,each loop Class B wiring supporting up to 250 device addresses0 NAC1- + + Communication Maximum 20 V peak-to-peak • NAC1+ - a - a _line voltage _ NAC2+ - EOLR Circuit CURent A max �C A A .—. .... ..—_ NAC2- + + 0 Circuit 660 total,0.5 pF max O _ dance T62 Isolators 64 maximum O NAC3- m NAC3+ 4+ + c G Class B Wiring Class A Wiring - NAC4- EOLR Marking indicates Loop I sEC Data Line <I + a (so NAC4+ output signal polarity + when the circuit is ac- -m "�e + + + TB6 tive.Polarity reverses Loop 1 PRI + when the circuit is not Loop Loop Loop Loop active.Wire notification device device device device accordingly. Loop card Data Line Class A wiring appliances NAO1 Notification appliance +N < + <I polarityshown in ac- Annunciator loop(TB4) A1+ rive state. te. NAC2- The control panel provides a connection for up to eight serially O NAC2+ + Q + Q driven and supervised remote annunciators. TTB2 Circuit specifications O - Device loops Class B(Style Y)or Class A(Style Z) O + Circuit voltage 2.55 V - Circuit current 30 mA max + Circuit Up to 8 annunciators or 4000 feet e impedance TB6 Class B Class A Channel 1 Channel 2 Channel 1 Channel 2 Auxiliary&Smoke power outputs(TB3) 0 t9 TB4 0 &®TB4 The control panel provides two auxiliary power outputs which can Annunciator Annundator be used for powering ancillary equipment such as remote an- - QCHI(+)IN ®CHI(+)IN nunciators and two wire smoke detectors. Aux 2 can be software t9 CHt(-)IN CHi(-)IN selected to operate continuous.The circuit is supervised for shorts and rounds. 0CH2(+)IN 0CH2(+)IN g ( cH2(-)IN 0 CH2(-)IN Note:For a complete list of devices that can be connected to this circuit, refer to the iO Series compatibility list(p/n 3101064). Alarm,trouble,and supervisory relay(TB3) Circuit specifications The trouble relay is normally-open,held closed, and opens on any Circuit voltage range 21.9 to 28.3 V trouble event or when the panel is de-energized.The supervisory Resettable circuit 24 VDC nominal at 500 mA relay is normally-open, and closes on any supervisory event.The (Aux power 2) alarm relay changes over on any alarm event. Continuous circuit 24 VDC nominal at 500 mA.Use this circuit for Relay specifications (Aux power 1) powering two-wire smoke detectors. - - ---- ---- Alarm Trouble Supervisory Note.Any current above 0.5 amp connected to both Aux 1 and 2 will reduce the total —_- Supervisory_ Note available NAC power by that amount. Type Form C Form A Voltage 24 VDC at 1 A resistive 24 VDC at 1 A resistive Relay circuits can only be connected to power-limited sources. Page 4 of 10 85005-0130 Issue 7.1 Option Cards " EXISTING ' i0500 panels are supported by a complete line of modules and SMK Smoke Power Converter related equipment that enhance performance and extend system The SMK Smoke Power Convert- ezwo capabilities.Option cards plug directly into the control panel main er Module provides a regulated eery + power circuit board or are connected to it with a ribbon cable.After in- power source for two-wire smoke (notr oe)- stallation,terminals remain accessible.The cabinet provides ample circuits connected to a Signature room for wire routing, keeping wiring neat at all times. data circuit.The SMK moni- eve; tors the operating power from SAW a's' thepower supply. powerP""'ro irt SA•ETH Ethernet Interface Card ppy.When Power SA-ETH wiring The SA-ETH card provides a begins to degrade,the SMK o o3 z r rEa goo standard 10/100 Base T Ethernet provides the necessary operating e Network cable Tnetwork connection for connect- voltage to the two-wire smoke r.°,°-°,1fe sm°ke detection circuits. detectors V ing to an Intranet,a local net- , 77� 9 ` ° 1 work,or the Internet.The card s,,,;1332j 1211109 - ® ® can be used to download 0 configuration programming from e T o e o o z ° the iO CU to the panel over the �sdn4: a network. B Data in 7i The Ethernet card is installed on Two-wire smoke the plastic assembly and con- d` tors Ethernet card °O 95i69,� 1S nects to the main circuit board 16131413 92,uvme via a ribbon cable. JP1 -` erm;n�e or to next SA-ETH specifications s a - UM 0 z r Ethernet 10/100 Base T Operating environment D9a° ut Temperature 32 to 120°F(0 to 49°C) Humidity 0 to 93%RH,noncondensing at 90°F SMK specifications --..-.---(32°C __-- -_- Input voltage 21.9 to 28.3 VDC(not resettable) Output voltage 24 VDC nom.at 200 rnA,max.,special applications XAL250 Loop Expander Card Ground fault 10 k ohm The XAL250 Loop Expander Card provides an additional Signature impedance Series device loop on the control panel.The card expands the Operating environment control panel's device capacity to 500 total device addresses,250 Temperature 32 tot 20°F(0 to 49°C) per loop.The card is compatible with Class B or Class A wiring. It Humidity 0 to 93%RH,noncondensing at 90°F(32°C) is compatible with 10500 control panels only. Storage temperature -4 to 140°F(-20 to 60°C) Compatible electrical North American 4 inch square x 2-1/2 in. The loop expander card connects to connector J7 on the main boxes (64 mm)deep 2 gang box or Standard 4 in. circuit board. square box 1-1/2 in.(38 dim)deep Class B Wiring Class A Wiring Wire size 14, 16,or 18 AWG wire(1.5, 1.0,or 0.75 sq. • - mm)(Sizes 16 and 18 AWG are preferred) Loop 1 SEC 0 Data Line .. ....._. • Loop 1 PRI Q + „(e = - - SA-232 RS-232 interface Loop Loop Loop Loop SA-232 wiring Loop card device device device device The SA-232 card provides an RS-232 Data Line interface with i0500 panels. It can be GND(black wire) -TXD(white wire) used for connecting a printer to the —RXD(red wire) XAL250 specifications control panel to print system events.The Device addresses on loop 125 detectors and 125 modules --v S®S®C-' WiringClass B(Style card also can be used for connecting a y °or Class A(Style Z) computer to download a configuration 0� � I 1 I Operating voltage 20 V peak-to-peak program from the i0-CU to the control -1 Operating current 0.5 A total panel. Circuit impedance 66 a 0.5 pF,max Terminal rating 12 to 18 AWG(0.75 to 2.5 sq mm) The RS-232 card is installed on the plastic assembly and con- Operating environment nects to the main circuit board via a ribbon cable. Temperature 32 to 120°F(0 to 49°C) Humidity 0 to 93%RH,noncondensing at 90°F SA-232 specifications • (32°C) Operating voltage Standard EIA-232 Terminal rating 12 to18 AWG(0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120°F(0 to 49°C) Humidity 0 to 93%RH,noncondensing at 90°F(32°C) Page 5 of 10 85005-0130 Issue 7.1 ** EXISTING ** SA-DACT Dialer SIGA-REL Releasing Module The SA-DACT provides communications between the control The SIGA-REL is an analog addressable module that communi- panel and the central station over a telephone line system. It sates directly with the fire alarm panel Signature loop controller.The transmits system status changes(events)to a compatible digital SIGA-REL controls sprinkler, pre-action and deluge systems,and alarm communicator receiver over the public switched telephone may also be used to release extinguishing agents such as CO2, network.The dialer is capable of single, dual, or split reporting Halon,or foam.The module is easily configured in the field and of- of events to two different account and telephone numbers.The fers a wide range of options that ensure dependable service,while • modem feature of the SA-DACT can also be used for uploading preventing the unnecessary release of extinguishing agent. and downloading panel configuration,history,and current status to a PC running the iO-CU. SIGA-REL specifications • SA-DACT Phone line 2 Input voltage 24 Vdc(power limited) wiring To well Supervisory current 25 mA,max. Phone line i hone jack Power riser B P Riser input current 4 amps maximum Phone sabres °° e ° Alarm 170 mA min.;4 A max. (supplied) 1 T RJ31 jacks Output rating 2 A @ 24 Vdc(per dreuit) Vri1_J Valves per circuit 4 valves,max. �I�V�I Release Max.supervisory current 0.4 mA(short circuit) The dialer phone lines connect circuits Nominal supervisory current 0.18 mA 47k Ohm EOL • '•gm•I ..e �nnciruits tobond P onneand1•°901 to connectors on the dialer's SEndoOfoinedde[iry gce 2A@)24Vdc(foe 26 Vdc,max. p each en ii-VerfrArcuit) r 9 q,. phone Ilne 2 connects to Max.supervisory current - Pre-release 0.4 mA(short circuit) connectorJl. alarm circuits Nominal supennsorycurtert 0.18 mA ❑�°.II.o-E t°�:r°p� Supervisory voltage End of line vice °Up6 giC❑❑U Max.sups v sory dere t 0.4 47k Ohm sresisthort circuit)circuit)26 Vdc,max.(open Manual Nominal supervscryctrrent 0.18 mA release input Supervisory voltage 26 Vdc,max.(open circuit) The SA-DACT queues messages and transmits them based on End of line device 47k Ohm resistor priority(alarm,supervisory,trouble,and monitor).Activations are circuit Circuit type Class B N.O.latching transmitted before restorations. Circuit capacitance 0.1 pF,max Max.supervisory current 0.4 mA(short circuit) The SA-DACT is installed on the plastic assembly and connects to Nominal supervisory cure rt 0.18 mA the main circuit board via a ribbon cable. Abort circuit Supervisory voltage 26 Vdc,max.(open circuit) End of line device 47k Ohm resistor SA-DACT specifications Circuit type Class B N.O.non-latching Phone line type One or two loop-start lines on a public, Circuit capacitance 0.1 pF,max switched network First alarm 3 A @ 24 Vdc Contact rating Phone line connector RJ-31/38X(C31/38X) output relay (0.6 power factor)Form C Communication formats Contact ID(SIA DC-05) Operating voltage 5.2 to 19.95 Vdc Operating environment Signature Supervisory current 1000 pA Data line Alarm current 1000 pA Temperature 32 to 120°F(0 to 49°C) Humidity 0 to 93%RH,noncondensing at 90°F Note:Output circuits are power-limited when the riser circuit is power-limited. (32°C) i0500 Control Panel ® Signature Series smoke detectors Compatible DACRs I- --- 1 Receiver Models Formats i Loop Controller i B Signature Series modules i Ademco 685 Contact ID ------,--------' Horn drevt FBII CP220 Contact ID Strobe circuit OH 2000 Contact ID M r 1 Service Disconnect Station Radionics D6600 Contact ID I ET Manual Abort station Silent Knight 9800 Contact ID I r1 Manual Release Saar, Sur-Gard SG-MLR1,MLR2 Contact ID Fire Alarm Control Panel 0 IMI First Adam output Relay 1;1 7 D I Auxiliary Releasing Module SO RELA-EOL Release Circuitl Power Supply (sIGA-REL) SD REL.A{OL Release ClrcuN2 WA MR For detailed specification and ordering information on the SIGH-REL,refer to Data Sheet 85001-0531 --Releasing Module. Page 6 of 10 85005-0130 Issue 7.1 Specifications ** EXISTING ** Device loops 1 loop,expandable to 2,Class A or B,each loop Battery placement iO500 cabinets accommodate up to 18 A/H supporting up to 250 device addresses batteries.Use a external cabinet for larger battery NAC circuits 4 Class B or 2 Class A,2.5 amps each sizes. Power supply 6.0 A total,2.5 A max.per circuit at 120/230 VAC Batteries Batteries must be sealed lead acid type only. 60 Hz Maximum charging capacity=26 Ah. 5.0 A total at 230VAC 50 Hz,2.5 A max.per Loop circuit Maximum loop resistance:66 D.Maximum loop circuit capacitance:0.5 F.Style 4,6,and 7 wiring.64 0.5 amps aux power isolators maximum. NAC Operating 24 VDC.NAC minimum voltage: 19.5 VDC @ 20.4 SIGA-UM/SIGA- 1.5 mA(see the UL and ULC compatibility list for voltage V battery voltage MAB for the maximum quantity of detectors per circuit) Loop circuit 20 V peak-to-peak Compatibility ID 100 operating voltage Alarm contact Form C 24 VDC 1 A(resistive load) SLC Primary power 120 VAC,60 Hz,230 VAC 50-60 Hz Trouble contact Form C 24 VDC Q 1 A(resistive load) Aux Power 1 24 VDC nominal at 500 mA.A SMK module is Supervisory contact Form A 24 VDC Q 1 A(resistive load) (Continuous circuit) required when using the SIGA-UM module to Environmental Temperature:0 to 49°C(32 to 120°F). support two-wire smoke detectors. Humidity:0 to 93%RH, noncondensing Aux Power 2 24 VDC nominal at 500 mA Terminal rating Al terminals rated for 12 to 18 AWG(0.75 to 2.5 mm2) (Resettable circuit) Serial Voltage:2.55 V.Current:30 mA max Auxiliary output 19 to 25.7 VDC communications Base panel Standby: 172 mA Remote annunciator 8 drops max, RS-485 Class A or B current draw Alarm:267 mA Input zones 32 max. Panel History Log 1,000 events Agency Listing UL864,UL2017,CSFM,ULC and NYFD#6020, FM approved Ordering Information Part Description iO500 Intelligent Multi-Loop Analog Systems iO500G 1 Loop system,500 point capacity,4 NACs,gray door,surface mount enclosure, 115 Vac,English. iO500G-2 1 Loop system,500 point capacity,4 NACs,gray door,surface mount enclosure,230 Vac,English. iO500GC Canada only:1 Loop system,500 point capacity,4 NACs,16-zone LED display,grey door,surface mount, 115 Vac,English. iO500G-F Canada only: 1 Loop system,500 point capacity,4 NACs,16-zone LED display,grey door,surface mount, 115VAC, French. iO500GD 1 Loop system,500 point capacity, two-line dialer,4 NACs,Gray door,surface mount enclosure, 115VAC transformer, English, iO50OR 1 Loop system,500 point capacity,4 NACs, red Door,surface mount enclosure, 115VAC transformer.English. iO500R-2 1 Loop system,500 point capacity,4 NACs,red door,surface mount enclosure,230VAC transformer, English. iO500RD 1 Loop system,500 point capacity,two line dialer,4 NACs,Red Door,surface mount enclosure, 115VAC transformer,English. iO500G-SP 1 Loop system,500 point capacity,4 NACs,gray door,surface mount enclosure, 115vac, Spanish. iO500G-2-SP 1 Loop system,500 point capacity,4 NACs,gray door,surface mount enclosure,230vac,Spanish. iO500G-PG 1 Loop system,500 point capacity,4 NACs,gray door,surface mount enclosure,115vac, Portuguese. iO500G-2-PG 1 Loop system,500 point capacity,4 NACs,gray door,surface mount enclosure.,230vac,Portuguese. SA-TRIM2 Flush mount trim,black Replacement Electronics 500e1ec-iO Replacement electronics kit,complete motherboard and user interface, English 500e1ec-iO-SP Replacement electronics kit,complete motherboard and user interface,Spanish 500elec-iO-PG Replacement electronics kit,complete motherboard and user interface,Portuguese 500e1ec-iO-FR Replacement electronics kit,complete motherboard and user interface,Canadian French Option Cards SA-DACT Dual Line Dialer/Modem,supports Contact ID,mounts in cabinet on base plate. SA-232 Serial Port(RS-232),for connection to printers&computers,mounts in cabinet to base plate SA-ETH Ethernet Port,Slave,mounts in cabinet on base plate. XAL250 Signature Loop Expansion Module.Adds second loop to iO500 systems,250 point capacity.Mounts in cabinet on main board. D16L-iO-2 LED Annunciator module. 16 X 2 LED zones(4 programmable for sup). Mounts in cabinet to right of LCD display for zones 17-32. D16L-iO-1 LED Annunciator module. 16 X 2-LED zones(4 programmable for sup). Mounts in cabinet to left of LCD display for zones 1-16. D8RY-10 2 Canada only:LED Annunciator module,two LEDs per zone, 16 zones(4 alarm only,8 supervisory only,4 alarm or supervisory). Mounts in cabinet to right of LCD display for zones 17-32. D8RY-iO-1 Canada only:LED Annunciator module,two LEDs per zone, 16 zones(4 alarm only,8 supervisory only,4 alarm or supervisory). Mounts in cabinet to left of LCD display for zones 1-16. Page 7 of 10 85005-0130 Issue 7.1 ** EXISTING ** Remote Annunciators(refer to Data Sheet 85005-0128) LCD Remote Annunciators(mount to standard 4"square electrical box) RLCD Remote Annunciator,4X20 LCD&Common Indicators for displaying system status.Gray housing. RLCD-R Remote Annunciator,4X20 LCD&Common Indicators for displaying system status.Red housing. RLCD-C Remote Annunciator,4X20 LCD.Common controls and status indicators.Gray housing. RLCD-CR Remote Annunciator,4X20 LCD.Common controls and status indicators. Red housing. RLCD-SP Remote Annunciator,4X20 LCD.Common system status indicators.White housing.Spanish. RLCD-PG Remote Annunciator,4X20 LCD.Common system status indicators.White housing.Portuguese. RLCD-C-SP Remote Annunciator,4X20 LCD.Common controls and status indicators.White housing.Spanish. RLCD-C-PG Remote Annunciator,4X20 LCD.Common controls and status indicators.White housing. Portuguese. RLED-C-SP Remote Annunciator,common controls and status indicators. 16 groups w/2 LEDs each for zone display.White housing.Spanish. RLED-C-PG Remote Annunciator,common controls and status indicators. 16 groups w/2 LEDs each for zone display.White housing.Portuguese. GCI Graphic Annunciator Driver Master for R Series annunciators.Outputs for 32 LEDs,connection to common control switches and LEDs. GCIX Graphic Annunciator Driver Expander for use with GCI Masters.Outputs for 48 LEDs,24 switch inputs for R-Series annunciators. For French common control,add suffix F to model number. LED Remote Annunciators&Expander(mount to standard 4"square electrical box) RLED-C Remote Annunciator.Common controls and status indicators with 16 X 2-LED groups for zone display.Gray housing. RLED-CF Remote Annunciator.Common controls and status indicators with 16 X 2-LED groups for zone display.Gray housing,French. RLED-CR Remote Annunciator.Common controls and status indicators with 16 X 2-LED groups for zone display.Red housing. RLED24 Remote Annunciator Zone expander.24 X 2-LED groups with custom label areas for display of alarm and trouble.Gray housing. RLED24R Remote Annunciator Zone expander.24 X 2-LED groups with custom label areas for display of alarm and trouble. Red housing. Remote Annunciator Cabinets&Accessories RA-ENC1 Remote Annunciator Enclosure,key locked with plexiglass window for one RLCD(C)or RLED(C). RA-ENC2 Remote Annunciator Enclosure,key locked with plexiglass window with space for 2 of either RLCDx,RLEDx or RLED24. RA-ENC3 Remote Annunciator Enclosure,key locked with plexiglass window with space for 3 of either RLCDx, RLEDx or RLED25. • RKEY Keyswitch,single gang,provides key operated enable or disable of common controls on RLCD or RLED units. LSRA-SB Surface Mount Box-for R Series single units. Programming Tools 10-al EST Series configuration and diagnostics utility. 260097 RS232 cable,4 conductor,DB9 PC interface Intelligent Analog Addressable Devices & Accessories Part# Description _._...... _._ Ship wt. Intelligent Detectors&Bases SIGA2-PHCOS Intelligent Multisensor Photoelectric/Heat Detector with carbon monoxide sensor SIGA2-PHS Intelligent Multisensor Photoelectric/Heat Detector SIGA2-PHSB Intelligent 4D Multisensor Detector(Black)-UL/ULC Listed SIGA2-PCOS Intelligent Photoelectric Detector with carbon monoxide sensor SIGA2-PS Intelligent Photoelectric Detector 0.4(0.16) SIGA2-HRS Intelligent combination fixed temperature/rate-of-rise heat detector SIGA2-HFS Intelligent fixed temperature heat detector SIGA2-HCOS Intelligent fused temperature heat detector with CO sensor SIGA2-COS Intelligent Carbon Monoxide Detector SIGA-HFS Intelligent Fixed Temperature Heat Detector SIGA-HRS Intelligent Fixed Temperature/Rate-of-Rise Heat Detector SIGA-IPHS Intelligent 40 Multisensor Detector SIGA-IPHSB Intelligent 4D Multisensor Detector(Black) 0.5(0.23) SIGA-PHS Intelligent 3D Multisensor Detector SIGA-PS Intelligent Photoelectric Detector SIGA-SD Intelligent Duct Detector SIGA-SB Detector Mounting Base SIGA-SB4 4-inch Detector Mounting Base c/w SIGA-TS Trim Skirt SIGA-RB Detector Mounting Base w/Relay SIGA-RB4 4-inch Detector Mounting Base /w Relay c/w SIGA-TS Trim Skirt 0.2(0.09) SIGA-IB Detector Mounting Base w/Fault Isolator SIGA-IB4 4-inch Detector Mounting Base w/Fault Isolator c/w SIGA-TS Trim Skirt SIGA-LED Remote Alarm LED SIGA-AB4G Audible(Sounder)Base 0.3(0.15) Page 9 of 10 85005-0130 Issue 7.1 • ** EXISTING ** SIGA-TS4 Trim Skirt(supplied with 4-inch bases) 0.1 (.04) SIGA-AB4GT Audible(Sounder)Base for CO and Fire Detectors 0.3(0.15) SIGA-TCDR Temporal Pattern Generator 0.3(0.15) Modules SIGA-CC1 Single Input Signal Module(Standard Mount) 0.5(0.23) SIGA-MCC1 Single Input Signal Module(UIO Mount) 0.18(0.08) SIGA-CC1 S Synchronization Output Module(Standard Mount) 0.5(0.23) SIGA-MCC1S Synchronization Output Module(U10 Mount) 0.18(0.08) SIGA-CC2 Dual Input Signal Module(Standard Mount) 0.5(0.23) SIGA-MCC2 Dual Input Signal Module(U1O Mount) 0.18(0.08) SIGA-CR Control Relay Module(Standard Mount) 0.4(0.15) SIGA-MCR Control Relay Module(U10 Mount) 0.18(0.08) SIGA-CRR Polarity Reversal Relay Module(Standard Mount) 0.4(0.15) SIGA MCRR Polarity Reversal Relay Module(UIO Mount) 0.18(0.08) SIGA-RM1 Riser Monitor Module(Standard Mount) 0.5(0.23) SIGA-MRM1 Riser Monitor Module(Plug-in) 0.18(0.08) SIGA-IO Input/Output Module(Standard Mount) 0.34(0.15) SIGA-MIO Input/Output Module(Plug-in) 0.22(0.10) SIGA-MAB Universal Class A/B Module(Plug-in) 0.18(0.08) SIGA-CT1 Single Input Module 0.4(0.15) SIGA-CT2 Dual Input Module 0.4(0.15) SIGA-MCT2 Dual Input Plug-in(U10)Module 0.1 (0.05) SIGA-IM Fault Isolator Module 0.5(0.23) SIGA-MM1 Monitor Module 0.4(.15) SIGA-WTM Waterflow/Tamper Module 0.4(.15) SMK Smoke Power Converter Module 0.4(0.15) SIGA-U1O2R Universal Module Board w/Riser Inputs-Two Module Positions 0.32(0.15) SIGA-UIO6R Universal Module Board w/Riser Inputs-Six Module Positions 0.62(0.28) SIGA-UIO6 Universal Module Board-Six Module Positions 0.56(0.25) SIGA-REL Analog addressable releasing module 0.5(0.23) 276A-REL Manual releasing station(single-action), English markings,black text on yellow polycarbonate body. 1.0(0.45) 278A-REL Manual releasing station(double-action). English markings,black text on yellow polycarbonate body. 1.0(0.45) RELA-ABT Manual Abort Station.English markings, black text on yellow polycarbonate body. 1.0(0.45) RELA-SRV-1 Service Disconnect Switch.One n/c contact and one n/o contact.English markings,white text on blue 1.0(0.45) polycarbonate body. RELA-EOL Polarized end-of-line relay.English markings on stainless steel cover. 0.2(0.1) Accessories GC' Graphic Annunciator Driver,provides outputs for common indicators and 32 alarm/supv zones as well as inputs for common switches. Provided with a snap track for mounting in custom graphic enclosures. CTM City Tie Module.Provides connection to a local energy fire alarm box. 0.6(0.3) RPM Reverse Polarity Module 3.0(1.36) BC-1 Battery Cabinet. 14.0"x 18.25"x 7.25". Holds 2 12V24A batteries. 50.0(22.7) BC-1 R Battery Cabinet-Red. 14.0"x 18.25"x 7.25".Holds 2 12V24A batteries. 50.0(22.7) BC-1 EQ Seismic hardening Kit for iO series panels. Includes battery hardening for BC-1 enclosure and components to harden panel internal components. See note below. MFG-A Multifunction Fire Cabinet,8"x 14"x 3.5"-RED. 20.6(9.4) PT 1 S System Printer-Desktop style. 35.6(16.6) Note: For earthquake anchorage,including detailed mounting weights and center of gravity detail,please refer to Seismic Application Guide 3101676-EN. Approval of panel anchorage to site structure may require local AHJ,structural,or civil engineer review. Standby batteries must be mounted externally from fire panel in separately mounted BC-1 enclosure.Order BC-1 and BC-1 EQ separately. Page 9 of 10 85005-0130 Issue 7.1 ** EXISTING ** EDWARDS Contact us... Email: edwards.fire@fs.utc.com Web: 1vw w.es t-fire.com EST is an EDWARDS brand. 1016 Corporate Park Drive Mebane,NC 27302 In Canada,contact Chubb Edwards... Email: inquiries@chubbedwards.com Web: www.chubbedwards.com ©2013 UTC Fire&Security Americas Corporation,Inc.All rights reserved. Specifications subject to change without notice.Edwards is part of UTC Climate,Controls&Security,a unit of United Technologies Corporation. Page 10 of 10 85005-0130 Issue 7.1 Strobes,Horns,Balls.Chimes cEDWARDs ALERT : ........... Genesis LED "" "'" •eeesseeeseseese --Heegese»esese FIf E r� G1 Series as{{{e{\{s Compact Notification Devices " ell 11::;:.;:; c : us 521 8. jj fir, 55389 .r' tEjr) 7125-1657:0506 7135-1657:0502 FC Overview Standard Features Genesis LED G1 Series horns and LED strobes feature a sleek • High Performance LED Strobe Technology low profile design and energy-efficient technology that makes -Ultra low device current consumption them less expensive to install and operate by reducing overhead. -High efficiency optics High performance LEDs require fewer circuits and power supplies. -Selectable 15, 30, or 75 cd light output These new appliances are designed with energy-efficiency and life -LED devices may be mixed with legacy Xenon strobes safety in mind. • Efficient Audible Output Genesis LED G1 Series uses high efficiency optics,combined -Selectable high or low dB horn output with patented electronics,to deliver a highly controlled and -Selectable temporal or steady horn output efficiently focused light distribution pattern in exchange for lower -Improved audio frequency range for better wall penetration current requirements.Strobes feature field-selectable 15,30, • Low-profile Design or 75 cd light output. p g -Compact design... single gang mounting Compared with Xenon-type strobes,Genesis LED G1 Series -Ultra-slim...protrudes about 1"from the mounting surface appliances need fewer power supplies and often smaller wire -Attractive appearance... no visible mounting screws gauge,which lightens conduit requirements.They are also • Multiple"FIRE" Marking Options backwards compatible with legacy strobes,so there's no need -Order English, French,Spanish or no FIRE markings to replace all your existing devices to upgrade to new LED -Change markings at any time with quick-swap covers technology. In fact,G1 strobes can be mixed on the same circuit and used in the same field of view as Xenon-based strobes.This • Easy to Install makes Genesis LED G1 Series ideal for new installations and -Diagnostic test points streamline device circuit testing retrofits alike. -Fits standard 1-gang electrical boxes, no trim ring needed Field-configurable sound output levels provide the flexibility - Optional trim ring available for 4-inch square boxes modern life safety projects demand,while the Genesis LED - Slide switches for field configuration control protocol keeps multiple strobes on compatible NAC -12 to 18 AWG in-out screw terminals for quick wiring circuits synchronized to well within NFPA 72 requirements. Serviceability is another area where G1 Series appliances shine. The innovative under-cover diagnostic test points provide easy access to device circuit testing while mounted. Page 1 018 E85001-0667 Issue 1 Application Genesis LED G1 Series horns and strobes mount to any standard Strobes one-gang surface or flush electrical box. Matching optional G1 T trim rings are available to cover oversized openings and can Genesis LED G1 Series strobes are UL 1971-listed for use accommodate one-gang or four-inch square boxes.Optional indoors as wall-mounted public-mode notification appliances color matched single-gang surface boxes are also available. for the hearing impaired. Prevailing codes require strobes to be used where ambient noise conditions exceed 105 dBA(87 dBA (.0.) One-gang in Canada),where occupants use hearing protection,and in t Electrical Box areas of public accommodation as defined in the Americans 0 �;, lam Ring Bookplate with Disabilities Act. �,% "41�I Synchronization is important in order to avoid epileptic sensitivity. ty,,;. ,ir" pis- Signaling Appliance P , jl 01 All Genesis LED strobes exceed UL synchronization requirements (,. ,I rl!/I `\ „Alt �' (within 10 milliseconds over a two-hour period)when used with -'J %,9 - " a1 Appliance Cover a synchronization source.See the specifications table for a list ,I;!lil :I 'J010 /,�j%, of compatible sources. 0;7,41. 1 Horns r 'i I - e t Air a 01 Genesis LED horn output reaches as high as 92 dBA and features Two-gang I�/ an improved audio frequency range compared with other Genesis Electrical Box 1 LED horns.This results in excellent sound penetration through walls and a clear warning of danger.They can also be set for high , or low dBA output.This setting reduces horn output by about 6 dBA. Horn-only models may be ceiling-mounted or wall-mounted Optional and may be configured for either coded or non-coded notification I !�. Trim Ping appliance circuits. t, Using a trim ring is optional -� 4-inch Octagon except when installing the ll The suggested sound pressure level for each signaling zone used 10sinaling appliance on electrical Electrical Box e with alarm signals is at least 15 dBA above the average ambient bowidies greats than three inches sound level, or 5 dBA above the maximum sound level having a '4. duration of at least 60 seconds,whichever is greater.These values are measured at five feet(1.5 m)above the floor.The average 00 ambient sound level is A-weighted,fast response sound pressure I ?, measured over a 24-hour period. ® 4-inch Square Doubling the distance from the signal to the ear will theoretically Electrical Box result in a 6 dBA reduction of the received sound pressure level. The actual effect depends on the acoustic properties of materials in the space.A 3 dBA difference represents a barely noticeable change in volume. Installation Wiring All Genesis LED devices come with mounting screws for easy — T —installation.The tab at the bottom of the device unlocks the cover Ooto reveal the mounting holes.The shallow depth of Genesis LEDHorn/strobe Horn strobe devices leaves ample room behind them for extra wiring.Oncecircuit in � circuit out installed with the cover in place, no mounting screws are visible. + 1 ,O'0 t t :oil■ t + ICI■;e;L :■I��I�I■:el ■ICI P +� LIL----. ' 1 ri �''�� 14 OP Signal polarity shown in the active condition. • o . l ,I Page 2 of a E85001-0667 Issue 1 Dimensions Field Configuration G1 Notification Appliances Temporal horn and horn-strobe models are factory set to sound in a three-pulse temporal pattern. By sliding the tone selector switch, 1-1/8• 2.86 cm 3' horn-only units may be configured for constant horn output that (7.62 cm) can be coded at precise intervals by EDWARDS control panels I and control modules. II I FORE t Horns and horn-strobes are factory set for high dB output. Low tcioiliiiONOlit o°o°o°o°o°o'o'oecio`o ' dB output may be selected by sliding the tone selector switch. ® ...0000..... This reduces the output by about 6 dBA. }Il ! Genesis LED clear strobes and horn-strobes may be set for 15, y � � 4-5/8' 30, or 75 candela output.The output settingis changed bysimply- ` 7111'. (11.75 cm) removing the cover and sliding the candela switchto the desired �� �t��\� setting.The device does not have to be removed from the wall �i �"�'� to change the output setting.The setting remains visible through r a small window on the left-hand side of the device after the cover \it s closed. T3 temporal horn,high dB E( T3 temporal horn,low dB Constant horn,high dB G1T Trim Ring Constant horn,low dB 9/16" _ I I.,1 !!!! II 75 candela _1I;/ 30 candela frh Ito l 15 candela 1`-. �..u. 5-7/8' i 4 (14.92 cm) Operating current Horns Strobes Sound 16 to 33 16 to 33 Strobe 16 to 33 16 to 33 l setting VDC VFWR setting VDC VFWR 1 O C-LOW 13 mA 15 mA 15,30,75 24 mA 32 mA C HIGH 23 mA 29 mA T-LOW 13 mA 15 mA T-HIGH 23 mA 29 mA Diagnostics Horn-Strobes !!!! Strobe setting Sound setting 16 to 33 VDC 16 to 33 VFWR �1 15,30 75 C-Low,T Low 35 mA 43 mA (� ) ¢ C-High,T High 45 mA 55 mA e I Mk ,le:p. _ a__..-ri, 111111r oll Test points indicated above are used to validate the Notification Appliance Circuit and verify device function. Pogo 3 o16 E85001-0667 Issue 1 Sound Output Light Distribution Reverberant dBA(UL 464) Horizontal Left 0 Sound setting Horn Horn-strobe 30 25 20 15 15 20 zs 30 C-LOW 80 80 35 35 C-HIGH 86 86 40 iAlt 40 46011111 45 T-LOW 80 80 so 50 T-HIGH 86 86 ss 55 60 60 65 65 70 _fi4--1 70 Anechoic dBA(CAN/ULC-S525) 75 75 Sound setting Horn Horn-strobe B0 80 C-LOW 86 86 ea � .., Zr ,� . ' 90 C-HIGH 92 92 T-LOW 86 86 o T-HIGH 92 92 �� 15 '� 20 f� 25 Sound pattern(ULC) 30 35 Axis Angle Change in output 40 45°and 115° -3 dBANIPIP 5045 Horizontal 5°and 130° -6 dBA - 55 _ 60 65°and 135° 3 dBA 70 65 Vertical Bottom Vertical 45°and 140° -6 dBA 90 85 80 75 Measured UL Minumum Specifications Operating voltage 16 to 33 VDC, 16 to 33 VFWR Horn signal type Constant or T3 temporal Light output 15,30,or 75 candela Strobe flash rate 1 fps(flash per second)approx. 20 D max.between any two devices. Synchronization (To determine allowed wire resistance, refer to these specifications, and the specifications for the synchronized signal source.) EDWARDS CC Series Signal Modules,Booster and Auxiliary Power Supplies, Synchronization sources and Intelligent and Conventional Control Panels Wire size 12 to 18 AWG(0.75 to 2.50 mm°) Dimensions(WxHxD) 3 x 4-5/8 x 1-1/8 in.(7.62 x 11.75 x 2.86 cm) Strobe-to-box -0.71 inches(-1.8 cm) center offset Compatible electrical boxes[1] 1-gang,2-gang,4-inch octagon,4-inch square Trim rings G1 TR,G1TW-Dimensions 5 x 5-7 x 9/16 in.(12.7 x 14 92 x 1.43 cm) FCC,ICC,UL1971,UL1638,UL464, CSFM Agency Listings (All models comply with ADA code of federal regulation Chapter 28 Part 36 final rule) Operating environment Temperature 32 to 122°F(0 to 50°C) Relative humidity 0 to 93%noncondensing Ill Electrical boxes must be at least 1-1/2 in.(3.81 cm)deep.Electrical boxes greater than three inches wide require a trim ring. Page 4 of 6 E85001-0667 Issue 1 Ordering Information • = • '•• • • Replacement Appliance Covers Color Marking G1ARF Red FIRE G1ARA-CVR Red ALERT G1ARF-FR Red FEU G1ARF-CVR Red FIRE G1ARF-FR-CVR Red FEU U G1ARF-SP Red FUEGO G1ARF-SP-CVR Red FUEGO G1ARN Red None G1ARN-CVR Red None G1AWF White FIRE GIAWA-CVR White ALERT Home ... . _ _ " selectable G1AWF-FR White FEU Horn G1AWF-CVR White FIRE High/low dB --- -- - ---G1AWF-SP Covers G1AWF-FR-CVR White FEU White FUEGO " G1AWF-SP-CVR White FUEGO G1AWN White None GIAWN-CVR White None GIVRF Red FIRE G1VRA-CVR Red ALERT G1VRF-FR Red FEU G1VRF-CVR Red FIRE -- G1 VRF-SP Red FUEGO G1VRF-FR-CVR Red FEU G1VRN Red None G1VRF-SF-CVR Red FUEGO G1VWA` White ALERT G1VRN-CVR Red None G1VWA-CVR White ALERT G1VWF White FIRE — Strobes __ lobe G1VWF-CVR White FIRE Selectable G1VWF-FR White FEU Covers G1VWF-FR-CVR White FEU 15,30,75 cd G1VWF-SP White FUEGO G1VWF-SP-CVR White FUEGO G1VWN White None G1VWN-CVR White None GIAVRF Red FIRE GIAVRA-CVR Red ALERT G1AVRF-CVR Red FIRE GIAVRF FR Red FEU GIAVRF-FR-CVR Red FEU ILG1AVRF-SP Red FUEGO G1AVRF-SP-CVR Red FUEGO G1AVRN Red None GIAVRN-CVR Red None G1AVWF White FIRE G1AVWA-CVR White ALERT Horn-strobes _. ---"-- -""- Selectable GIAVWF FR White FEU Horn-strobe GIAVWF-CVR White FIRE 15,30,75 cd, - -.---.. _._-._,-..--__. ..-_ Covers G1AVWF-FR-CVR White FEU High/low dB GIAVWF-SP White FUEGO GIAVWF-SP-CVR White FUEGO G1AVWN White None G1AVWN-CVR White None Accessories EllG1TR Trim ring,G1 Series,red G1TW Trim ring,G1 Series,white 27193-11 One gang surface mount box,red 27193-16 One-gang surface mount box,white Model Number Syntax, Appliances Model Number Syntax, Replacement Covers Genesis LED Series —Genesis LED Series G1=Wall mount appliances G1=Wall mount appliances Housing Color Housing Color R=Red R=Red W=White W=White i I I I Cover G1 AVRF Housing Marking G1 AVRF-CVR Designation I I N=None 'ALERT Marking I I I F-FR=FEU available on white Cover Marking F-SP=FUEGO strobe model with N=None Functions F=FIRE clear lens only. —Functions F-FR=FEU A=Horn only A=ALERT' See replacement A=Horn only F-SP=FUEGO V=Strobe only covers for more V=Strobe only F=FIRE AV=Horn-Strobe options. AV=Horn-Strobe A=ALERT Page 5 of 8 E85001-0667 Issue 1 R BS Contact us... Email: edwards.fire@fs.utc.com Web: edwards-fire.corn 1016 Corporate Park Drive Mebane,NC 27302 EDWARDS is a registered mark in the United States and other countries. ©2018 United Technologies Corporation. All rights reserved. 0 E85001-0667 5 Issue 1 Strobes,Horns,Bells,Chimes EDWARDS Genesis LED F'R� GCSeries • elf • • • Ceiling Mount • • • • . . . . . . .•ti Notification Devices .r ::. .:.•. • • • • • • ,`� ... .. ••••:.'................. �. 5218, I` ;„ S5389 �► ®> FC f Overview Standard Features Genesis LED GC Series horns and LED strobes feature a sleek • High Performance LED Strobe Technology low profile design and energy-efficient technology that makes —Ultra low device current consumption allows: them less expensive to install and operate by reducing overhead. —More devices per circuit High performance LEDs require fewer power supplies, backup —Ability to use lower gauge wire power,and batteries.These new appliances are designed with, —Longer wire runs energy-efficiency,and life safety in mind. —Fewer booster power supplies Genesis LED GC Series uses high efficiency optics,combined —High tableffice ncy optics — with patented electronics,to deliver a highly controlled and Selectable 15,30, 75, or 115 cd light output efficiently focused light distribution pattern in exchange for — LED devices may be mixed with legacy Xenon strobes lower current requirements.Strobes feature field-selectable • Efficient Audible Output 15,30,75, or 115 cd light output. —Selectable high or low dB horn output —Selectable temporal or steady horn output Compared with Xenon-type strobes,Genesis LED GC Series —Improved audio frequency range for better wall penetration appliances need fewer power supplies and often smaller wire gauge,which lightens conduit requirements.They are also • Low-profile Design backwards compatible with legacy strobes,so there's no need to —Ultra-slim...protrudes about 1.5"from the mounting surface replace all your existing devices to upgrade to new LED technology. —Attractive appearance... no visible mounting screws In fact,GC strobes can be mixed on the same circuit and used in • Multiple"FIRE"Marking Options the same field of view as Xenon-based strobes.This makes Genesis —Order English, French, Spanish or no FIRE markings LED GC Series ideal for new installations and retrofits alike. —Change markings at any time with replaceable Field-configurable sound output levels provide the flexibility quick-swap covers modem life safety projects demand,while the Genesis LED • Easy to Install control protocol keeps multiple strobes on compatible NAC —Pre-install and pre-wire with convenient universal room circuits synchronized to well within NFPA 72 requirements. side wiring plate Serviceability is another area where GC Series appliances shine. — Check electrical continuity on room side wiring plate with The universal room side wiring plate allows for pre-installation included diagnostics check bar and electrical wiring as well as checking continuity with the —Diagnostics port streamlines device circuit testing included diagnostics check bar.GC Series devices can then be -Fits 1-gang, 2-gang,4-inch octagon,and 4-inch square easily snapped into place with the confidence of knowing the electrical boxes wiring is correct.The innovative under-cover diagnostic test points —Optional red and white trim plates available provide easy access to device circuit testing while mounted. —Slide switches for field configuration —12 to 18 AWG in-out screw terminals for quick wiring Page 1 of 6 E85001-1021 Issue 1.1 Application Genesis LED GC Series horns,strobes,and horn-strobes mount Strobes to any standard one-gang,two-gang,4-inch octagon,and 4-inch square electrical box.Matching optional GCT trim rings are available Genesis GC Series strobes are UL 1971-listed for use indoors to cover oversized openings.Optional color matched double-gang as ceiling-mounted public-mode notification appliances for the surface boxes are also available.Genesis LED GC series are listed to hearing impaired. Prevailing codes require strobes to be used be both wall mounted or ceiling mounted. where ambient noise conditions exceed 105 dBA(87 dBA in Canada),where occupants use hearing protection,and in areas of public accommodation as defined in the Americans with (1) /'C Disabilities Act. Synchronization is important in order to avoid triggering seizures Ili in people with photosensitive epilepsy.All Genesis strobes exceed __ IIII' i.I.UL synchronization requirements(within 10 milliseconds over a ` two-hour period)when used with a synchronization source. See (2) I I the specifications table for a list of compatible sources. \ Horns /� Genesis horn output reaches as high as 92 dBA and features an - e__ improved audio frequency range compared with other Genesis I I horns.This results in excellent sound penetration through walls and a clear warning of danger.Horn only models may be configured for (3) +�1 either coded or non-coded notification appliance circuits.They can \, ��l�l also be set for high or low dBA output.This setting reduces horn I!�� Jam- ''% Ly-___-_4/1/j=' I output by about 6 dBA. I I- I The suggested sound pressure level for each signaling zone used (4)\1 with alarm signals is at least 15 dBA above the average ambient (5) sound level,or 5 dBA above the maximum sound level having a \ duration of at least 60 seconds,whichever is greater.These values are measured at five feet(1.5 m)above the floor.The average ...44 ►jj ,y ambient sound level is A-weighted,fast response sound pressure ,�%�./ measured over a 24-hour period. `4, i' .%�•, Doubling the distance from the signal to the ear will theoretically t` ... result in a 6 dBA reduction of the received sound pressure level. (1)Elect cal Box (3)Trim Plate(optional) The actual effect depends on the acoustic environment in the space. Wiring Wiring plate(required,ordered separately) A 3 dBA difference represents a barely noticeable change in volume. (4)Machine screw(2X,supplied with winng plate) (5)GC signaling appliance Installation Genesis GC horns and strobes mount to the required GP10 room side wiring plate.The GP10 mounting plate is ordered separately Wiring from the GC device in packs of 10 for convenient pre-installing and pre-wiring.The device can be removed easily from the room side wiring plate by pushing up with a screwdriver.The cover can also o i be removed from the device easily with a screwdriver to access the ''�j o I Qo light and sound output settings and a diagnostics test port for voltage testing. 0 Horn/strobe + +Horn/strobe circuit in I I 11 I - circuit out Removing Cover Removing Device (signal polarity I:OI� I: Butt t shown in the ..-1l((♦9.151P'14k)1111MI�I iMINIIIINIMINA\ C1B1 active condition) �. lMilil__,�lit!lIli 1--Shorting Clip j 111111( ik I�o�l '/I erMINIIMIIIIIMINI 1IIIIIIIIIIIIIrailliiiiilliiraoep.,--- ...., x I Page 2 of 6 E85001-1021 Issue 1.1 Dimensions Field Configuration GC Notification Appliances Temporal horn and horn-strobe models are factory set to sound in 82,. a three-pulse temporal pattern. By sliding the tone selector switch, (4.62 cm) 6.6' horn only models may be configured for constant horn output that (17.27 cm) — can be coded at precise intervals by EDWARDS control panels and control modules. ., Note:Temporal 3 coding is the required output for fire notification devices per NFPA 72.Any device coding other than temporal 3 is at the discretion and approval of the local authority having jurisdiction(AHJ). 'eo o°o°o°o°o°o°° �' �"„ e o°o o°o°oo -; , t �l', l (.. o -,,°o.� Horns and horn-strobes are factory set for high dB output. Low \1: o�' )11 dB output may be selected by sliding the tone selector switch. /•': 0008 ptoo °�f /► I� o ono 0 o.. o q� This reduces the output by about 6 dBA. `�° ® Genesis LED clear strobes and horn-strobes may be set for 15, \_, � 30, 75, or 115 candela output.The output setting is changed by �. \` simply removing the cover and sliding the candela switch to the �� desired setting.The device does not have to be removed from the wall to change the output setting. The setting remains visible — through a small window on the device after the cover is closed. GCT Trim Plate(optional) Light and Sound Output Settings (0.76 cm) .9.6c ,�/`. (2692 cm) IGH ) OW ) ) i213i Ii ii = —li IGH �) (4) 100 :; 4.4. 61,4 I o ° ±� 0 0 (1)Constant,low dB ir;'' lit' I t (6) (2)Constant,high dB E # 0 itq 8 (3)T3 temporal,low dB I)'„ i l i (7) (4)T3 temporal,high dB ‘�, 4AV- �' ( ) (6)75 candela(5)115 s ',\1�I�P ��', 7 (7)30 candela (8)15 candela - Diagnostics ,,,& ,. � Operating current ye, mom. Horns Strobes i � . � ,������ � Sound 16 to 33 16 to 33 Strobe 16 to 33 16 to 33 °��rtr 0 )1) v� setting VDC VFWR setting VDC VFWR ` I'', C Low, 20 mA 25 mA 15.30, 35 mA 45 mA T Low 75,115 \\,���•�•,,` �/ T Highh 30 mA 40 mA u .i Horn-Strobes Test points indicated — — Strobe above are used to validate �� setting Sound setting 16 to 33 VDC 16 to 33 VFWR the Notification Appliance ftweem....� 15,30, C-Low,T-Low 50 mA 60 mA Circuit and verify device function. _ 75, 115 C-High,T-High 60 mA 75 mA Page 3of6 E85001 -1021 Issue 1.1 Sound Output Light Distribution Horn&Horn-Strobe Horizontal Left ze 15 m 2,0 0 5 10 15 20 Horizontal Right Sound setting Reverberant AnechoiC r 30 25 25 30 (UL484) (CAN/ULC-592+) 35 35 • C-Low,T-Low 80 dBA 86 dBA 40 200 40 45 45 l C-High,T-High 86 dBA 92 dBA 50 50 55 I 55 60 60 65 65 70 t u • `~I 70 75 a ti, (5 Sound pattern-Horn Models(ULC) 80 + 50 1 80 85 85 Axis Ana's('. Output(dBA) 90 t 90 Horizontal 115 and 55 93.3 85lik 85 Vertical 125 and 50 91.7 80 80 75 ]5 70 ]0 65 65 60 60 55 55 Sound pattern-Horn-Strobe Models(ULC) 50 50 45 45 Axis Angie PI Output(dBAi 40 40 35 35 Horizontal 145 and 35 93.0 155 and 35 90.8 30 25 20 15 10 5 0 5 10 15 20 25 ao Vertical Bottom Vertical 135 and 35 92.0 Measured 155 and 25 85.4 UL Minumum Specifications Operating voltage 16 to 33 VDC, 16 to 33 VFWR Horn signal type Constant or TC3 temporal Light output 15,30,75,or 115 candela Strobe flash rate 1 fps(flash per second)approx. Synchronization 20 D max.between any two devices.To determine allowed wire resistance,refer to these specifications,and the specifications for the synchronized signal source. Synchronization Sources Edwards CC Series Signal Modules,Booster and Auxiliary Power Supplies, Intelligent and Conventional Control Panels Wire size 12 to 18 AWG(0.75 to 2.50 mm7) Mounting Wall or Ceiling mount Dimensions(0 x D) 6.8 x 1.82 in.(17.27 x 4.62 cm) Strobe-to-box center offset -1.70 inches(-4.32 cm) Compatible electrical boxes[1] 1-gang,2-gang,4-inch octagon.4-inch square Trim plates GCTR,GCTW 10.6 x 0.3 in.(26.92 x 0.76 cm) Operating environment Temperature 32 to 122°F(0 to 50°C) Relative humidity 0 to 93%noncondensing Storage Temperature -40 to 158 F(-40 to 70 C) [1]Electrical boxes must be at least 1-1/2 in.(3.81 cm)deep. Page 4 o1 6 E85001-1021 !Niue 1.1 Ordering Information Notification Appliances Color Marking Replacement Appliance Covers Color Marking GCARF Red FIRE GCARA-CVR Red ALERT GCARF-FR Red FEU GCARF-CVR Red FIRE GCARF-FR-CVR Red FEU GCARF-SP0 Red FUEGO GCARF-SP-CVR Red FUEGO GCARN Red None GCARN-CVR Red None GCAWF White FIRE GCAWA CVR White ALERT Horns GCAWF-FR White FEU Horn GCAWF-CVR White FIRE Covers GCAWF-FR-CVR White FEU GCAWF-SP White FUEGO _----- ---- --- -- -- - GCAWF-SP-CVR White FUEGO GCAWN White None GCAWN-CVR White None GCVRF Red FIRE GCVRA-CVR Red ALERT GCVRF-FR Red FEU GOVHF-CVR Red FIRE ,--^ -,,. GCVRF-SP Red FUEGO II GCVRF-FR CVR Red FEU irt GCVRN Red None II r GCVRF-SP CVR Red FUEGO k:. GCVWF White FIRE GCVRN-CVR Red None ■ - GCVWA-CVR White ALERT Strobes GCVWF-FR White FEU _...._--_.-_... .. .. Strobe GCVWF-CVR White FIRE GCVWF-SF' White FUEGO Covers GCVWF FR-CVR White FEU GCVWN White None GCVWF-SP-CVR White FUEGO GCVWN-CVR White None GCAVRF Red FIRE .._._._.._.. GCAVRF-FR Red FEU GCAVRA-CVR Red ALERT GCAVRF-CVR Red FIRE GCAVRF-SP Red FUEGO Nm GCAVRF-FR-CVR ii ii Red FEU ZF GCAVRN Red None GCAVRF-SP-CVR Red FUEGO u R GCAVWF White FIRE a GCAVRN-CVR Red None Horn-strobes GCAVWF-FR White FEU GCAVRA-CVR White ALERT GCAVWF SP White FUEGO Horn-strobe GCAVWF-CVR White FIRE Covers GCAVWF-FR-CVR __White FEU GCAVWN White None GCAVWF-SP-CVR White FUEGO GCAVWN-CVR White None Accessories Giii. Room Side Wiring Trim plate,GC Series, Trim late,GC Series, GP10 Plate(required, IC) GCTR red GCTW p ordered separately) white 27193-21 Two-gang surface 27193-26 Two-gang surface • mount box,red mount box,white Model Number Syntax, Appliances Model Number Syntax, Replacement Covers —Genesis Series GC=Ceiling mount appliances —Genesis Series GC=Ceiling mount appliances Housing Color R=Red Housing Color • W=White R=Red • W=White GCAVRF Housing Marking I I Cover N=None ALERT Marking GCAVRF-CVR Designation F-FR=FEU available on white i FSP=FUEGO strobe model only. Cover Marking Functions F=FIRE See replacement N=None A=Horn only A=ALERT* covers for more Functions F-FR=FEU V=Strobe only options. A=Horn onlyF-SP=FUEGO AV=Horn-Strobe V=Strobe or At F=FIRE AV=Horn-Strobe A=ALERT Page 5 of 6 E85001-1021 Issue 1.1 -DWARDS Contact us Phone: 800-655-4497(Option 4) Email: Mwards.fire Carrier.Com Website: edwardsfiresatetv.com 8985 Town Center Pkvd/ Bradenton,FL 34202 I� ®2020 Carrier All rights reserved. a Page 8 of 6 E85001 -1021 Issue 1.1 RECEIVED BMANHESTER CITY OF TIGARD TEc -)7Y SYSTEMS BUILDING DIVISION EQUIPMENT SUBMITTAL for Courtyard by Marriott - Pool Conversion 15686 SW Sequoia Pkwy, Tigard, OR 97224 Fire Alarm System Addition/Alteration submitted by GB Manchester Inc CCB 202097 MODEL # DESCRIPTION MFG i0500GD FIRE ALARM CONTROL PANEL (EXISTING) EST "I GIAVWF HORN-STROBE,WALL, WHITE EST G1VWF STROBE,WALL,WHITE EST GCAVWF HORN-STROBE, CEILING,WHITE EST GCVWF STROBE,CEILING,WHITE EST 6000 NE 88th St,Vancouver, WA. 98665 Portland 503.287.1112 Vancouver 360.816.0484 Toll Free 877.816.0484 THIS PAGE INTENTIONALLY LEFT BLANK ** EXISTING ** Small Building Fire Alarm Solutions EST Life Safety & Communications i0500 Intelligent = _VIM gig mom .. ont 000 Dap Life Safety System WOO/ FDNY COA 6020 howl 7165-1657: 0244 S3000 Overview Features The EST i0500 intelligent life safety system offers the power of • Comes standard with one loop(expandable to two)that high-end intelligent processing in a configuration that delivers an supports up to 250(expandable to 500)intelligent devices: uncomplicated solution for small to mid-sized applications.With each i0500 loop supports up to 125 detectors and up to 125 intelligent detection,electronic addressing,automatic device map- modules. ping, optional Ethernet°connectivity,and a full line of easily-con- • Supports Signature Series intelligent modules and detectors figured option cards and modules,this flexible system offers offers versatility that benefits building owners and contractors alike. • Combines the Signature intelligent releasing module with Signature multisensor detectors for reliable suppression The i0500 provides one Class A or Class B analog device loop • Four Class B NACs or two Class A NACs. that supports up to 250 device addresses.A second 250-point loop may be added to the i0500 to expand total system capacity • Form C contacts for alarm and trouble, Form A for supervisory to up to 500 device addresses.The panel includes four NACs that • Electronic addressing with automatic device mapping may be wired for either Class A or Class B operation. • Optional Ethernet port for diagnostics, programming and a The i0500 supports a wide range of accessories and related variety of system reports equipment,including: • Two programmable switches with LEDs and custom labeling • Signature Series intelligent modules, detectors, and bases • Supports Genesis horn silence over two wires and UL • R-Series remote annunciators 1971-compliant strobe synchronization • option cards that expand system capacity and extend system • Supports up to eight serial annunciators,(LCD, LED-only,and capabilities graphic interface). • Listed for releasing applications using SIGA-REL • 1,000 event panel history log • Fully integrated CO detection using Signature Series 2 detec- • Can use existing wiring for most retrofit applications tors with or w/o audible signaling • Upload/download remotely or locally • Two-level maintenance alert reporting • Pre-alarm and alarm verification by point • Adjustable detector sensitivity • 4 x 20 character backlit LCD display • Optional earthquake hardening:OSHPD seismic pre-approval for component Importance Factor 1.5 Pogo 1 of 10 85005-0130 Issue 7.1 l ** EXISTING ** . 1 Application Operation The i0500 life safetysystem is apowerful intelligent solution for The frontpanelprovides � i1� Y 9 KID; filler small to mid-sized buildings.Advanced analog technology delivers an easy-to-use operator's Htl, l q1� the benefits of flexible system installation,while a clean and easy- interface, as well as all kill v: j� to-operatate user interface makes panel operation and system the necessary controls for H1�; Q' Wit, silo, HIS, :©.: •., iti11 maintenance quick and intuitive. front panel programming. K1r_ ems' 1.Ls, p� i1� A large back-lit 80-char- H1 , ( ®CM 'i1im, The smart choice acter LCD displays ice; ( ®® 'KjINIEN Signature Series electronic addressing eliminates the tedium of system status,event R1 Woo -i1i setting dipswitches,and automatic device mapping ensures that details,and programming 31111 000 �12 I-Ljmm each device resides on the system at its correct location. Mean- prompts. Large tactile iiil l OO®0 ffi 31N while,innovative programming allows the designer to customize control buttons are easy a., ,Im 0®0® 1� the system to precisely suit the needs of the building owner. to see in low light condi- tions,and bright multi-color LEDs offer at-a-glance status indica- Flexibility built right in tion. Two fully-programmable front panel switch/LED combinations pro- vide an added measure of flexibility.Their slide-in labels take the mystery out of custom applications,and present a clean finished Control buttons appearance. 1 Button Description Reset Initiates a system reset. Perfect for retrofits A The i0500 is particularly well-suited to retrofit applications.All Silencel Silences the panel and remote annunciators during an active trouble,supervisory,or alarm event and connections are made over standard wiring-no shielded cable acknowledges new event activations. required.This means that in most situations existing wiring can Signal Silence Alarm mode:Silences active notification appliances. be used to upgrade a legacy control panel to i0500 technology Pressing Signal Silence a second time turns NACs back without the expense or disruption of rewiring the entire building. on. Drill Initiates a drill confirmation.Pressing drill a second time Signals with a difference turns off the drill function. i0500 NACs are configurable to fully support the advanced signal- Remote Dialer:Disables or enables dialer. ing technology of Edwards Genesis and Enhanced Integrity notifi- Disconnect Dialer set to modem only:Disables or enables the cation appliances.These devices offer precision synchronization of common alarm relay. strobes to UL 1971 standards. For Genesis devices,enabling this Left arrow Display mode:Moves the cursor to the left. Menu mode:Toggles between programming feature allows connected horns to be silenced while strobes on selections. R arrow panelRight arrow Display mode:Moves thee cursor to the right. the same two-wire circuit continue to flash until the is reset. t. Menu mode:Retrieves a programming option's sub Clear-cut remote annunciation menu and toggles between a programming option's Remote annunciation is a strong suit of the i0500. Up to eight an- selections. nunciators can be installed on a single system.Compatible annun- Up arrow Display mode:Advances to the previous event. ciators include a range of LED and LCD models that provide zone _._..._"_ Menu mode:Moves the cursor up. or point annunciation,as well as common control capabilities. Down arrow Display mode:Advances to the next event. Menu mode:Moves the cursor down. The i0500 also supports graphic annunciation with optional Enter Display mode:Displays selected event details. graphic annunciator interface modules. Each interface provides Menu mode:Retrieves a programming option's sub common control, indicators,and LED drivers.Consult the Order- menu or jumps to the Save function in the menu. ing Information section for details. Entry mode:Enters the selected data into the system. Cancel Display mode:Exits the detailed information display. Menu mode:Exits the current menu level. A complete line of accessories Entry mode:Clears the current entry. The i0500 life safety system is supported by a complete line of Menu Display mode:Enters the menu mode intelligent detectors, modules and related equipment.Consult the Menu mode:Exits menu mode Ordering Information section for details. Space Enters a space,such as a space between words. Alphanumeric Entry mode:Pressing a button once enters the number keypad on the button.Pressing the button twice enters the secondary value. Programmable These buttons can be programmed to control outputs, buttons disable devices or unlatch system outputs.The buttons can be labeled with a slip-in insert. Page 2 of 10 85005-0130 Issue 7.1 System n stem LEDs ** EXISTING ** el Operation Options LED Description Language English or French Alarm Red LED. On steady when there is an active Marketplace U.S.or Canada alarm. AC fail delay Off:Off-premise notification of an AC power failure Trouble Yellow LED. Flashes when there is a fault on a is immediate. monitored circuit or system component, or when a 1 to 15 hours:Delays the off-premise notification of circuit is disabled. an AC power failure by the time period selected. Sup Yellow LED. On steady when there is an active Zone resound On:NACs resound each time a device in the zone goes into alarm even if they were silenced supervisory event. Off:Inhibits the NACs from turning on again(after AC Power Green LED. On when the panel has AC power. they were silenced)when a second device in the Disable Yellow LED. Double-flashes when there is a dis- zone goes into alarm. abled circuit, alarm relay,or remote annunciator. Reset inhibit after Off:Panel reset is operational immediately. Ground Yellow LED. On steady during an active ground fault. NACs turn on 1 minute:Panel reset is inhibited for one minute. Fault Auto signal Off'Allows immediate silencing of signals from an Test Yellow LED. Flashes when performing an audible silence off-normal condition using the Signal Silence button walk test. Stead Indicates a silent test. 5 to 30 minutes:Delays the silencing of signals y from an off-normal condition by disabling the Signal Monitor Yellow LED. On steady when there is an active Silence button for the time period selected. monitor event. Day start Start time for daytime sensitivity Service Yellow LED. Indicates that detector needs servicing. Night start Start time for nighttime sensitivity Detector Date U.S.:MM/DD/YYYY,Canada:DD/MM/YYYY Signal Yellow LED.On steady indicates that NAG circuits Sounder Base Six configuration settings Silence are turned off but the panel is still in alarm Mapping Disabled:Device mapping is not available Remote Yellow LED.On steady indicates that the dialer Enabled:Device mapping is available Disconnect is disabled or that the alarm relay is enabled or LCD banner Banner text for line one and line two.Each line is disabled when the dialer is set to modem only. capable of up to 20 characters. Drill Yellow LED. Indicates that the panel is in drill. Event notification Zone:When a device is a member of a zone,only Reset Yellow LED Indicates that the panel is resetting. the zone information is sent to the LCD display, LEDs,printer,and dialer. i Panel Yellow LED. Indicates that the panel has been Zone/device:Zone information is sent to the LCD i Silence silenced during an active trouble, supervisory,or display and LEDs.Device information is sent to the alarm event and indicates that new event active- printer and dialer. tions have been acknowledged. Device.Only device information is reported. User Keys Yellow LED. Programmable. Programming Dimensions i0500 life safety systems are simple to set up,yet also offer ad- Surface mounting holes vanced programming features that put these small building panels 4-D2-vi —D3—► into a class of their own.The auto programming feature quickly — gets the panel operational using factory default settings. Basic 0°• '® ® b 8® ° zone and point settings can be programmed easily through the ° ° 4 front panel interface,so the system is up and running in no time. II m For more advanced system configuration and correlation groups o programming, i0500 systems interface to a PC running compat- II 01 ible i0-CU software.This option offers full system configuration ➢ I 0 c c in the familiar Windows®operating environment.Connection is m typically made to a laptop through the panel's optional RS-232 00. Dt �[ ° D4 E communications port,which can also be used to connect a sys- 07 tem printer. - Among the many innovative features of i0500 control panels is the m optional network card.This module provides a standard 10/100 II ® rn Base T Ethernet®network connection that permits access to the 0 Surface mounting holes ° control panel from any remote location with the correct commu- 0. e ° ° nications protocols.The connection can be used to download to the panel from the i0-CU,or upload and view system reports I D6—v il using the i0-GU. D5 Available system reports include: • Correlation groups • Device details Panel dimensions,in(cm) • Device maintenance • History Model 7 DV D2 D3 D4 D5' D6 • Internal status • System configuration , 28.0 1 3.85 9.0 22.0 15.75 10.25 • System status 0500 Walk test ( (71:_) (9.8) (22.8) (55.8) (40.0) (26.0) • Dialer • CO runtime "Add 1-1/2 in.(3.81 cm)to D1 and D5 dimensions for trim kit. Page 3 of 10 85005-0130 Issue 7.1 Wiring & Configuration ** EXISTING ** Notification appliance circuits(TB2) Signature Device loop i0500 control panels come equipped with four notification ap- The system provides one device loop circuit with a total capacity pliance circuits.Each circuit can be individually configured for of 125 detectors and 125 module addresses.The loop circuit is continuous,temporal,synchronized, latching,and coded output. supervised for opens,shorts,and grounds. Circuit specifications The Signature Loop Controller uses broadcast polling and ad- Circuitvanced communications formats to regularly check the entire Circuit Type 4 Class B or 2 Class A,2.5 amps each � y Voltage 24 VFWR device circuit for anomalies. If a change of state is detected at the Current 6.0 A total.2.5 A max.per circuit at 120/230 VAC 60 Hz circuit level,the Loop Controller then uses a direct address search 5.0 A total at 230VAC 50 Hz,2.5 A max.per circuit to find the reporting device.This two-staged technique ensures Impedance 26 0 total,0.35 pF max that only new information is transmitted,thus allowing for a re- EOLR 15 K 0,1h W duced baud rate while still achieving nearly instant device reporting. • Circuit specifications 1 Device loops 1 loop,expandable to 2,Class A or B,each loop Class B wiring supporting up to 250 device addresses O- NAC1- . ' Communication Maximum 20 V peak-to-peak • NAC1+ all/, /`I line voltage NAC2- EOLR Circuit current 0.5 A max Circuit 660 total,0.5 pF,max O NAC2+ .11/111141Al impedance Tee Isolators 64 maximum (71- NAC3- e NAC3+ + a + 4 _ Class B Wiring Class A Wiring NAC4- EOLR Marking indicates Loop 1 SEC -m Data Line O + < + < h output signal polarity + NAC4+ 4 when the circuit is ac- ;'le + + + TBB two.Polarity reverses Loop 1 PRI + when the circuit is not Loop Loop Loop Loop active.wire notification Loop cent device device Data Line device device Class A wiring appliances accordingly. NAc1- Notification appliance + + polarity shown in ac- Annunciator loop(TB4)0 NACi+ Q a tive state. 0 NAC2- The control panel provides a connection for up to eight serially NAC2+ + a + c driven and supervised remote annunciators. TB2 Circuit specifications ___ 0 - Device loops Class B(Style Y)or Class A(Style Z) __ 175 + Circuit voltage 2.55 V - Circuit current 30 mA max Circuit Up to 8 annunciators or 4000 feet O + impedance TB6 Class B Class A Channel 1 Channel 2 Channel 1 Channel 2 + — + — + — + — Auxiliary&Smoke power outputs(TB3) 0 0 0 0 TB4 B & TB4 The control panel provides two auxiliary power outputs which can Annundator Annunciator be used for powering ancillary equipment such as remote an- 0 CH1(+)IN B CH1(+)IN nunciators and two wire smoke detectors. Aux 2 can be software 0 CH1(-)IN QCHi(-)IN selected to operate continuous.The circuit is supervised for shorts (Si CH2(+)IN (S)CH2(+)IN and grounds. 0 CH2(-)IN 1Sl CH2(-)IN Note: For a complete list of devices that can be connected to this circuit,refer to the i0 Series compatibility list(p/n 3101064). Alarm,trouble,and supervisory relay(TB3) Circuit specifications The trouble relay is normally-open,held closed,and opens on any Circuit voltage range 21.9 to 28.3 V trouble event or when the panel is de-energized.The supervisory Resettable circuit 24 VDC nominal at 500 mA relay is normally-open,and closes on any supervisory event.The (Aux power 2) alarm relay changes over on any alarm event. Continuous circuit 24 VDC nominal at 500 mA.Use this circuit for (Aux power 1) powering two-wire smoke detectors. Relay specifications Alarm Trouble Supervisory Note:Any current above 0.5 amp connected to both Aux 1 and 2 will reduce the total Type Form C Form A available NAC power by that amount. - ---- Voltage 24 VDC at 1 A resistive 24 VDC at 1 A resistive Relay circuits can only be connected to power-limited sources. Page 4 of 10 85005-0130 Issue 7.1 Option Cards ** EXISTING ** 10500 panels are supported by a complete line of modules and SMK Smoke Power Converter related equipment that enhance performance and extend system The SMK Smoke Power Convert- capabilities.Option cards plug directly into the control panel main er Module provides a regulated a 4 VDC +EA circuit board or are connected to it with a ribbon cable.After in- power source for two-wire smoke (ne re=ee)- [' � stallation,terminals remain accessible.The cabinet provides ample circuits connected to a Signature room for wire routing, keeping wiring neat at all times. data circuit.The SMK moni- tors the operating power from SMK s 5 1150-rverirl SA-ETH Ethernet Interface Card the power supply.When power °owe,out SA-ETH wiring The SA-ETH card provides a begins to degrade,the SMK 0 °,;, �� To network provides the necessary operating Network cable ar� connection standard 10/100 Base T Ethernet voltage to the two-wire smoke 1 network connection for connect- g Two-yore sruere detection circuits. detectors �I ng to an Intranet,a local net- Q, ■ 1 work,or the Internet.The card t,' a ,es,a,338i,:,,,°e ®p ® can be used to download JP1 - + ii configuration programming from o ' '- 8765 8o321 31 the i0-CU to the panel over the a network. oats, e The Ethernet card is installed on v�-w�Es,r" e ie.lels the plastic assembly and con- de ■ Ethernet card m GI.,.,.y;1' nects to the main circuit board 16 15 11 13 3 2,-;3,1 to 9 via a ribbon cable. 81511 -, Terminate °r t°next 6 6 um SA-ETH specifications 5 7 5 5 .3-i_,_____ ___ -_-__. ._..._._ -.-..-. •��' 3 Ethernet 10/100 Base T ■ Operating environment Data°"' Temperature 32 to 120°F(0 to 49°C) Humidity 0 to 93%RH,noncondensing at 90°F SMK specifications (32°C) .—... -- ---- ----- --.--- --- Input voltage 21.9 to 28.3 VDC(not resettable) Output voltage 24 VDC nom.at 200 mA,max..special applications XAL250 Loop Expander Card Ground fault 10 k ohm The XAL250 Loop Expander Card provides an additional Signature impedance Series device loop on the control panel.The card expands the Operating environment control panel's device capacity to 500 total device addresses, 250 Temperature 32 to 120°F(0 to 49°C) per loop.The card is compatible with Class B or Class A wiring. It Humidity 0 to 93%RH,noncondensing at 90°F(32°C) is compatible with 10500 control panels only. Storage temperature 4 to 140°F(-2D 10 60°C) Compatible electrical North American 4 inch square x 2-1/2 in. The loop expander card connects to connector J7 on the main boxes (64 mm)deep 2 gang box or Standard 4 in. circuit board. square box 1-1/2 in.(38 mm)deep • Class B Wiring Class A Wiring Wire size 14, 16,or 18 AWG wire(1.5, 1.0,or 0.75 sq. mm)(Sizes 16 and 18 AWG are preferred) Loop 1 SEC ® —Data Line Loop 1 PRI • + + + +® ��[e SA-232 RS-232 interface Loop Loop Loop Loop SA-232 wiring Loop card device device device device The SA-232 card provides an RS-232 Data Line interface with 10500 panels. It can be GND(clack wire) TXD(white wire) used for connecting a printer to the r RXD(red wire) XAL250 specifications control panel to print system events.The Device addresses on loop 125 detectors and 125 modules card also can be used for connecting a +®®S®r i Wiring Class B(Style Y)or Class A(Style Z) �r�., computer to download a configuration Operating voltage 20 V peak-to-peak program from the i0-CU to the control Operating current 0.5 A total ---. panel. Circuit impedance 66 0,0.5 pF,max Terminal rating 12 to 18 AWG(0.75 to 2.5 sq mm) The RS-232 card is installed on the plastic assembly and con- Operating environment nects to the main circuit board via a ribbon cable. Temperature 32 to 120°F(0 to 49°C) Humidity 0 to 93%RH,noncondensing at 90°F SA-232 specifications (32°C) Operating voltage Standard CIA-232 Terminal rating 12 to18 AWG(0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120°F(0 to 49°C) Humidity 0 to 93%RH,noncondensing at 90°F(32°C) Page 5 of 10 85005-0130 Issue 7.1 ** EXISTING ** SA-DACT Dialer SIGA-REL Releasing Module The SA-DACT provides communications between the control The SIGA-REL is an analog addressable module that communi- panel and the central station over a telephone line system. It cates directly with the fire alarm panel Signature loop controller.The transmits system status changes(events)to a compatible digital SIGA-REL controls sprinkler,pre-action and deluge systems,and I alarm communicator receiver over the public switched telephone may also be used to release extinguishing agents such as CO2, network.The dialer is capable of single,dual,or split reporting Halon,or foam.The module is easily configured in the field and of- of events to two different account and telephone numbers.The fers a wide range of options that ensure dependable service,while modem feature of the SA-DACT can also be used for uploading preventing the unnecessary release of extinguishing agent. and downloading panel configuration,history,and current status to a PC running the i0-CU. SIGA-REL specifications SA-DACT Phone line 2 Input voltage 24 Vdc(power limited) wiring aTo well Supervisory current 25 mA,max. Phone line 1 hone jack Power riser P Riser input current 4 amps maximum Phone cablesx • Alarm 170 mA min.;4 A max. • (supplied) I T• RJ31 jacks Output rating 2 A 124 Vdc(per dreutt) ElIT I Valves per circuit 4 valves,max. ll9l �llVl�l Release Max.supervisory current 0.4 mA(short circuit) The dialer hone lines connect circuits Nominal sLpervisorycurrent 0.18 mA I . to connectors on the dialer's Supervisory voltage 26 Vdc,max.(open circuit) '..''°•°Q End of line device 47k Ohm EOL 'soup. main circuit board.Phone line 1 :11Wa ET to connector J4 and Output rating 2 A Q 24 Vdc(for each °qr phone line 2 connects to Max.supervisory current circuit) ..C:''' CCM connector J1. Pre-release Nomi el y anent 0.4 mA(short circuit) {{�� alarm circuits 0.18 mA n❑❑ °,,gy�pp ° i. Supervisory voltage 26 Vdc,max.(open circuit) °o❑❑L_I ..• ,, . End of line device 47k Ohm resistor _ —.o g o D° Max supervisory current 0.4 mA(short circuit) Manual Nominal supervisory current 0.18mA release input Supervisory voltage 26 Vdc,max.(open circuit) The SA-DACT queues messages and transmits them based on End of line device 47k Ohm resistor priority(alarm,supervisory, trouble,and monitor).Activations are circuit Circuit type Class B N.O.latching transmitted before restorations. Circuit capacitance 0.1 pF,max Max.supervisory current 0.4 mA(short circuit) The SA-DACT is installed on the plastic assembly and connects to Nominal supervisorycurent 0.18 mA the main circuit board via a ribbon cable. Abort circuit Supervisory voltage 26 Vdc,max.(open circuit) End of line device 47k Ohm resistor SA-DACT specifications Circuit type Class B N.O.non-latching Phone line type One or two loop-start lines on a public, Circuit capacitance 0.1 pF,max switched network First alarm Contact rating 3 A @a 24 Vdc Phone line connector RJ-31/38X(C31/38X) output relay (0.6 power factor)Form C Communication formats Contact ID(SIA DC 05) Operating voltage 5.2 to 19.95 Vdc ------ Signature Operating environment Supervisory current 1000 pA Temperature 32 to 120°F(0 to 49°C) Data line Alarm current 1000 pA Humidity 0 to 93%RH,noncondensing at 90°F Note:Outour circuits are power-limited when the riser circuit is power-limited. (32°C) 10500 Control Panel ® Signature Senes smoke detectors Compatible DACRs -- — — — Receiver Models Formats Loop Controller i a si°°eura seriaa moamea Ademco 685 Contact ID -------1--------) Hornar°mt FBII CP220 Contact ID _ � I pu Shot*tircmt Osborne Hoffman OH 2000 Contact ID I" �, Shot*driamnnea Station Radionics D6600 Contact ID 1---1 Manoai A..rtstae°n Sur-Gardg SG-MLR1, MLR2 Contact ID Fire Alarm Control Panel © I First irm Output Station Silent Knight 9800 Contact ID F— M I,si Alarm ul°N Relay l 017 Di Auxiliary Releasing Module SD RELA-EOL Release Cirwill Power Supply (SIGA-REL) SD REL4 EOL Release Circuil2 I A ) 1 For detailed specification and ordering information on the SIGA-REL,refer to Data Sheet 85001-0531 --Releasing Module, Page 6 0110 85005-0130 Issue 7.1 Specifications ** EXISTING ** Device loops 1 loop,expandable to 2,Class A or B.each loop Battery placement i0500 cabinets accommodate up to 18 NH supporting up to 250 device addresses batteries.Use a external cabinet for larger battery NAC circuits 4 Class B or 2 Class A,2.5 amps each sizes. Power supply 6.0 A total,2.5 A max.per circuit at 120/230 VAC Batteries Batteries must be sealed lead acid type only. 60 Hz Maximum charging capacity=26 Ah. 5.0 A total at 230VAC 50 Hz,2.5 A max.per Loop circuit Maximum loop resistance:66 0.Maximum loop circuit capacitance:0.5 pF.Style 4,6,and 7 wiring.64 0.5 amps aux power isolators maximum. NAC Operating 24 VDC. NAC minimum voltage: 19.5 VDC©20.4 SIGA-UM/SIGA- 1.5 mA(see the UL and ULC compatibility list for voltage V battery voltage MAB for the maximum quantity of detectors per circuit) Loop circuit 20 V peak-to-peak Compatibility ID 100 operating voltage Alarm contact Form C 24 VDC 4 1 A(resistive load) SLC Primary power 120 VAC,60 Hz,230 VAC 50-60 Hz Trouble contact Form C 24 VDC @ 1 A(resistive load) Aux Power 1 24 VDC nominal at 500 mA.A SMK module is Supervisory contact Form A 24 VDC A 1 A(resistive load) (Continuous circuit) required when using the SIGA-UM module to Environmental Temperature:0 to 49°C(32 to 120'F). support two-wire smoke detectors. Humidity:0 to 93°ro RH,noncondensing Aux Power 2 24 VDC nominal at 500 rnA Terminal rating All terminals rated for 12 to 18 AWG(0.75 to 2.5 mm2) (Resettable circuit) Serial Voltage:2.55 V.Current:30 mA max Auxiliary output 19 to 25./VDC communications Base panel Standby: 172 mA Remote annunciator 8 drops max,RS-485 Class A or B current draw Alarm:267 mA Input tones 32 max. Panel History Log 1,000 events Agency Listing UL864,UL2017, CSFM, ULC and NYFD#6020, FM approved Ordering Information Part Description i0500 Intelligent Multi-Loop Analog Systems i0500G 1 Loop system,500 point capacity,4 NACs,gray door,surface mount enclosure, 115 Vac,English. 10500G-2 1 Loop system,500 point capacity,4 NACs,gray door,surface mount enclosure,230 Vac,English. i0500GC Canada only:1 Loop system.500 point capacity,4 NACs, 16-zone LED display,grey door, surface mount, 115 Vac,English. i0500G-F Canada only:1 Loop system,500 point capacity,4 NACs,16-zone LED display,grey door,surface mount, 115VAC, French. i0500GD 1 Loop system,500 point capacity,two-line dialer,4 NACs,Gray door,surface mount enclosure, 115VAC transformer,English. i0500R 1 Loop system,500 point capacity,4 NACs,red Door,surface mount enclosure, 115VAC transformer,English. i0500R-2 1 Loop system,500 point capacity,4 NACs,red door,surface mount enclosure,230VAC transformer,English. 10500RD 1 Loop system,500 point capacity,two-line dialer,4 NACs, Red Door,surface mount enclosure, 115VAC transformer,English. i0500G-SP 1 Loop system,500 point capacity,4 NACs,gray door,surace mount enclosure, 115vac,Spanish. i05003-2-SP 1 Loop system,500 point capacity,4 NACs,gray door,surface mount enclosure,230vac,Spanish. i0500G-PG 1 Loop system,500 point capacity,4 NACs,gray door,surface mount enclosure, 115vac, Portuguese. i0500G-2-PG 1 Loop system,500 point capacity,4 NACs,gray door,surface mount enclosure„230vac,Portuguese. SA-TRIM2 Flush mount trim,black Replacement Electronics 500e1ec-iO Replacement electronics kit,complete motherboard and user interface,English 500e1ec-i0-SP Replacement electronics kit,complete motherboard and user interface,Spanish 500e1ec-iO-PG Replacement electronics kit,complete motherboard and user interface, Portuguese 500e1ec-i0-FR Replacement electronics kit,complete motherboard and user interface,Canadian French Option Cards SA-DACT Dual Line Dialer/Modem,supports Contact ID,mounts in cabinet on base plate. SA-232 Serial Port(RS-232),for connection to printers&computers,mounts in cabinet to base plate SA-ETH Ethernet Port,Slave,mounts in cabinet on base plate. XAL250 Signature Loop Expansion Module,Adds second loop to i0500 systems,250 point capacity.Mounts in cabinet on main board. D16L-i0-2 LED Annunciator module, 16 X 2-LED zones(4 programmable for sup). Mounts in cabinet to right of LCD display for zones 17-32. D16L-i0-1 LED Annunciator module, 16 X 2-LED zones(4 programmable for sup). Mounts in cabinet to left of LCD display for zones 1-16. D8RY-i0-2 Canada only:LED Annunciator module,two LEDs per zone, 16 zones(4 alarm only,8 supervisory only,4 alarm or supervisory). Mounts in cabinet to right of LCD display for zones 17-32. D8RY-i0-1 Canada only:LED Annunciator module,two LEDs per zone, 16 zones(4 alarm only,8 supervisory only,4 alarm or supervisory). Mounts in cabinet to left of LCD display for zones 1-16. Page 7 0110 85005-0130 Issue 7.1 ** EXISTING ** Remote Annunciators(refer to Data Sheet 85005-0128) LCD Remote Annunciators(mount to standard 4"square electrical box) RLCD Remote Annunciator.4X20 LCD&Common Indicators for displaying system status.Gray housing. RLCD-R Remote Annunciator,4X20 LCD&Common Indicators for displaying system status.Red housing. RLCD-C Remote Annunciator,4X20 LCD.Common controls and status indicators.Gray housing. RLCD-CR Remote Annunciator,4X20 LCD.Common controls and status indicators.Red housing. RLCD-SP Remote Annunciator,4X20 LCD.Common system status indicators.White housing.Spanish. RLCD-PG Remote Annunciator,4X20 LCD.Common system status indicators.White housing. Portuguese. RLCD-C-SP Remote Annunciator,4X20 LCD.Common controls and status indicators.White housing.Spanish. RLCD-C-PG Remote Annunciator,4X20 LCD.Common controls and status indicators.White housing.Portuguese. RLED-C-SP Remote Annunciator,common controls and status indicators. 16 groups w/2 LEDs each for zone display.White housing.Spanish. RLED-C-PG Remote Annunciator,common controls and status indicators. 16 groups w/2 LEDs each for zone display.White housing. Portuguese. GCI Graphic Annunciator Driver Master for R-Series annunciators.Outputs for 32 LEDs,connection to common control switches and LEDs. • GCIX Graphic Annunciator Driver Expander for use with GCI Masters.Outputs for 48 LEDs,24 switch inputs for R-Series annunciators. For French common control,add suffix F to mode'number. LED Remote Annunciators&Expander(mount to standard 4"square electrical box) RLED-C Remote Annunciator.Common controls and status indicators with 16 X 2-LED groups for zone display.Gray housing. RLED-CF Remote Annunciator.Common controls and status indicators with 16 X 2-LED groups for zone display.Gray housing,French. RLED-CR Remote Annunciator.Common controls and status indicators with 16 X 2 LED groups for zone display.Red housing. R_ED24 Remote Annunciator Zone expander.24 X 2-LED groups with custom label areas for display of alarm and trouble.Gray housing. RLED24R Remote Annunciator Zone expander.24 X 2-LED groups with custom label areas for display of alarm and trouble.Red housing. Remote Annunciator Cabinets&Accessories RA-ENC1 Remote Annunciator Enclosure,key locked with plexiglass window for one RLCD(C)or RLED(C). RA-ENC2 Remote Annunciator Enclosure, key locked with plexiglass window with space for 2 of either RLCDx, RLEDx or RLED24. RA-ENC3 Remote Annunciator Enclosure, key locked with plexiglass window with space for 3 of either RLCDx, RLEDx or RLED25. RKEY Keyswitch,single gang,provides key operated enable or disable of common controls on RLCD or RLED units. LSRA-SB Surface Mount Box-for R Series single units. Programming Tools iO-CU EST Series configuration and diagnostics utility. 260097 RS232 cable,4 conductor,DB9 PC interface Intelligent Analog Addressable Devices & Accessories Part q Description Ship wt. Intelligent Detectors&Bases SIGA2-PHCOS Intelligent Multisensor Photoelectric/Heat Detector with carbon monoxide sensor SIGA2-PHS Intelligent Multisensor Photoelectric/Heat Detector SIGA2-PHSB Intelligent 4D Multisensor Detector(Black)-UL/ULC Listed SIGA2-PCOS Intelligent Photoelectric Detector with carbon monoxide sensor SIGA2-PS Intelligent Photoelectric Detector 0.4(0.16) SIGA2-HRS Intelligent combination fixed temperature/rate-of-rise heat detector SIGA2-HFS Intelligent fixed temperature heat detector SIGA2-HCOS Intelligent fixed temperature heat detector with CO sensor SIGA2-COS Intelligent Carbon Monoxide Detector SIGA-HFS Intelligent Fixed Temperature Heat Detector SIGA-HRS Intelligent Fixed Temperature/Rate-of-Rise Heat Detector SIGA-IPHS Intelligent 4D Multisensor Detector SIGA-IPHSB Intelligent 4D Multisensor Detector(Black) 0.5(0.23) SIGA PHS Intelligent 3D Multisensor Detector SIGA-PS Intelligent Photoelectric Detector SIGA-SD Intelligent Duct Detector SIGA-SB Detector Mounting Base SIGA-SB4 4-inch Detector Mounting Base c/w SIGA-TS Trim Skirt SIGA RB Detector Mounting Base w/Relay SIGA-RB4 4-inch Detector Mounting Base /w Relay c/w SIGA-TS Trim Skirt 0.2(0.09) SIGA-IB Detector Mounting Base w/Fault Isolator SIGA-IB4 4-inch Detector Mounting Base w/Fault Isolator c/w SIGA-TS Trim Skirt SIGA-LED Remote Alarm LED SIGA-AB4G Audible(Sounder)Base 0.3(0.15) Page 8 of 10 85005-0130 Issue 7.1 ** EXISTING ** SIGA-TS'- Trim Skirt(supplied with 4-inch bases) 0.1 (.04) SIGA-AB4GT Audible(Sounder)Base for CO and Fire Detectors 0.3(0.15) SIGA-TCDR Temporal Pattern Generator 0.3(0.15) Modules SIGA-CC1 Single Input Signal Module(Standard Mount) 0.5(0.23) SIGA-MCC1 Single Input Signal Module(UIO Mount) 0.18(0.08) SIGA-CC1S Synchronization Output Module(Standard Mount) 0.5(0.23) SIGA-MCC1S Synchronization Output Module(UIO Mount) 0.18(0.08) SIGA-CC2 Dual Input Signal Module(Standard Mount) 0.5(0.23) SIGA-MCC2 Dual Input Signal Module(UIO Mount) 0.18(0.08) SIGA CR Control Relay Module(Standard Mount) 0.4(0.15) SIGA-MCR Control Relay Module(UIO Mount) 0.18(0.08) SIGA-CRR Polarity Reversal Relay Module(Standard Mount) 0.4(0.15) SIGA-MCRR Polarity Reversal Relay Module(U10 Mount) 0.18(0.08) SIGA-RM1 Riser Monitor Module(Standard Mount) 0.5(0.23) SIGA-MRM1 Riser Monitor Module(Plug-in) 0.18(0.08) SIGA-IO Input/Output Module(Standard Mount) 0.34(0.15) SIGA-MIO Input/Output Module(Plug-in) 0.22(0.10) SIGA-MAB Universal Class A/B Module(Plug-in) 0.18(0.08) SIGA-CT1 Single Input Module 04(0.15) SIGA-CT2 Dual Input Module 0.4(0.15) SIGA-MCT2 Dual Input Plug-in(UIO)Module 0.1 (0.05) SIGA-IM Fault Isolator Module 0.5(0.23) SIGA-MM1 Monitor Module 0.4(.15) SIGA-WTM Waterflow/Tamper Module 0.4(.15) SMK Smoke Power Converter Module 0.4(0.15) SIGA-UIO2R Universal Module Board w/Riser Inputs-Two Module Positions 0.32(0.15) SIGA-UIO6R Universal Module Board w/Riser Inputs-Six Module Positions 0.62(0.28) SIGA-U1O6 Universal Module Board-Six Module Positions 0.56(0.25) SIGA-REL Analog addressable releasing module 0.5(0.23) 276A-REL Manual releasing station(single-action).English markings, black text on yellow polycarbonate body. 1.0(0.45) 278A-REL Manual releasing station(double-action). English markings, black text on yellow polycarbonate body. 1.0(0.45) RELA-ABT Manual Abort Station.English markings, black text on yellow polycarbonate body. 1.0(0.45) RELA-SRV-1 Service Disconnect Switch.One n/c contact and one n/o contact.English markings,white text on blue 1.0(0.45) polycarbonate body. RELA-EOL Polarized end-of-line relay. English markings on stainless steel cover. 0.2(0.1) Accessories GCI Graphic Annunciator Driver,provides outputs for common indicators and 32 alarm/supv zones as well as inputs for common switches.Provided with a snap track for mounting in custom graphic enclosures. CTM City Tie Module.Provides connection to a local energy fire alarm box. 0.6(0.3) RPM Reverse Polarity Module 3.0(1.36) BC-1 Battery Cabinet. 14.0"x 18.25"x 7.25".Holds 2 12V24A batteries. 50.0(22.7) BC-1 R Battery Cabinet-Red. 14.0"x 18.25"x 7.25".Holds 2 12V24A batteries. 50.0(22.7) BC-1 EO Seismic hardening Kit for iO series panels. Includes battery hardening for BC-1 enclosure and components to harden panel internal components. See note below. MFC-A Multifunction Fire Cabinet,8"x 14"x 3.5" -RED. 20.6(9.4) PT-1 S System Printer-Desktop style. 36.6(16.6) Note: For earthquake anchorage,including detailed mounting weights and center of gravity detail,please refer to Seismic Application Guide 3101676-EN. Approval of panel anchorage to site structure may require local AHJ,structural,or civil engineer review. Standby batteries must be mounted externally from fire panel in separately mounted BC-1 enclosure.Order BC-1 and BC-1 EQ separately. Page 9 of 10 85005-0130 Issue 7.1 ** EXISTING ** • EDVVAROS Contact us... Email: edwards.fire@fs.utc.com Web: www.est-fire.com EST is an EDWARDS brand. 1016 Corporate Park Drive Mebane,NC 27302 In Canada,contact Chubb Edwards... Email: inquiries@chubbedwards.com Web: www.chubbedwards.com ®2013 UTC Fire&Security Americas Corporation,Inc.All rights reserved. Specifications subject to change without notice.Edwards is part of UTC Climate,Controls&Security,a unit of United Technologies Corporation. pPage 10 of 10 85005-0130 Issue 7.1 Strobes,Horns,Bells,Chimes DWARS ALERT Genesis LED • . """"••••" ................ aiii�i�iiiiii G1 Series FIREi, Compact Notification Devices $, 1.:;, ;: C®urn S218. r - s5369 ill 7125-1657:0506 7135 116679502 FC Overview Standard Features Genesis LED G1 Series horns and LED strobes feature a sleek • High Performance LED Strobe Technology low profile design and energy-efficient technology that makes -Ultra low device current consumption them less expensive to install and operate by reducing overhead. -High efficiency optics High performance LEDs require fewer circuits and power supplies. -Selectable 15,30,or 75 cd light output These new appliances are designed with energy-efficiency and life -LED devices may be mixed with legacy Xenon strobes safety in mind. • Efficient Audible Output Genesis LED G1 Series uses high efficiency optics,combined -Selectable high or low dB horn output with patented electronics,to deliver a highly controlled and -Selectable temporal or steady horn output efficiently focused light distribution pattern in exchange for lower - Improved audio frequency range for better wall penetration current requirements.Strobes feature field-selectable 15,30, or 75 cd light output. • Low-profile Design -Compact design...single gang mounting Compared with Xenon-type strobes,Genesis LED G1 Series -Ultra-slim... protrudes about 1"from the mounting surface appliances need fewer power supplies and often smaller wire -Attractive appearance... no visible mounting screws gauge,which lightens conduit requirements.They are also • Multiple"FIRE"Marking Options backwards compatible with legacy strobes,so there's no need -Order English, French,Spanish or no FIRE markings to replace all your existing devices to upgrade to new LED technology. In fact, G1 strobes can be mixed on the same circuit - Change markings at any time with quick-swap covers and used in the same field of view as Xenon-based strobes.This • Easy to Install makes Genesis LED G1 Series ideal for new installations and -Diagnostic test points streamline device circuit testing retrofits alike. -Fits standard 1-gang electrical boxes, no trim ring needed Field-configurable sound output levels provide the flexibility - Optional trim ring available for 4-inch square boxes modern life safety projects demand,while the Genesis LED - Slide switches for field configuration control protocol keeps multiple strobes on compatible NAC - 12 to 18 AWG in-out screw terminals for quick wiring circuits synchronized to well within NFPA 72 requirements. Serviceability is another area where G1 Series appliances shine. The innovative under-cover diagnostic test points provide easy access to device circuit testing while mounted. Pegs+ore E85001-0667 leave 1 Application Genesis LED G1 Series horns and strobes mount to any standard one-gang surface or flush electrical box. Matching optional G1T Strobes trim rings are available to cover oversized openings and can Genesis LED G1 Series strobes are UL 1971-listed for use accommodate one-gang or four-inch square boxes.Optional indoors as wall-mounted public-mode notification appliances color matched single-gang surface boxes are also available. for the hearing impaired. Prevailing codes require strobes to be used where ambient noise conditions exceed 105 dBA(87 dBA chi One-gang in Canada),where occupants use hearing protection,and in Imo electrical Box areas of public accommodation as defined in the Americans Trim Fling Backplate with Disabilities Act. 1 S'4 Synchronization is important in order to avoid epileptic sensitivity. '\ r.!s !> .,- {�I Slgnalmg Appliance All Genesis LED strobes exceed UL synchronization requirements �\1/^y M` �i i l 4). i�r / Appliance Cover (within 10 milliseconds over a two-hour period)when used with $1,,Jl, ,nx�a a synchronization source.See the specifications table for a list .I!Isi�i,1�i1i ' 3), of compatible sources. ���0� �1'� �!" „ _ Horns �� o to Genesis LED horn output reaches as high as 92 dBA and features 0 Two-gang ��/ vaudio frequency range com compared with other Genesis Electrical Box an improved q cYp I LED horns.This results in excellent sound penetration through c walls and a clear warning of danger.They can also be set for high 3 or low dBA output.This setting reduces horn output by about 6 dBA.Horn-only models may be ceiling-mounted or wall-mounted (or Optional _ and may be configured for either coded or non-coded notification 4 >.-o Trim Ring appliance circuits. , ( Using a trim ring is optional 4-inch tn Octagon except when installing the The suggested sound pressure level for each signaling zone used ® . Electrical Box signaling appliance on electrical with alarm signals is at least 15 dBA above the average ambient (�� wide. i boxes greater than three inches sound level,or 5 dBA above the maximum sound level having a \ duration of at least 60 seconds,whichever is greater.These values are measured at five feet(1.5 m)above the floor.The average Co* ambient sound level is A-weighted,fast response sound pressure I measured over a 24-hour period. 4-inch Square Doubling the distance from the signal to the ear will theoretically V Electrical Box result in a 6 dBA reduction of the received sound pressure level. ®, The actual effect depends on the acoustic properties of materials '® in the space.A 3 dBA difference represents a barely noticeable change in volume. Installation Wiring All Genesis LED devices come with mounting screws for easy __--_— __ installation.The tab at the bottom of the device unlocks the cover rn Horn/strobe to reveal the mounting holes.The shallow depth of Genesis LED Horn/strobep-1- devices leaves ample room behind them for extra wiring. Once circuit in Iftcircuit out installed with the cover in place, no mounting screws are visible. + CI■:Gr ■III.III■:0r ■CI + /� I ' Lj L!H 1, ilr p I [JN Signal polarity shown in the active condition. '/, ial\ Ni Page 2 of a E85001-0667 Issue 1 Dimensions Field Configuration G1 Notification Appliances Temporal horn and horn-strobe models are factory set to sound in a three-pulse temporal pattern. By sliding the tone selector switch, 1-1/8" (2.86 cm 3" horn-only units may be configured for constant horn output that (7.62 cm) can be coded at precise intervals by EDWARDS control panels and control modules. ,' I FORE i s e o o e e e o e o.a a e e. Horns and horn-strobes are factory set for high dB output. Low 000000000000000o dB output may be selected by sliding the tone selector switch. IN I 0.•••• •i'• This reduces the output byabout 6 dBA. .....:.:e e .:.te P Cfll ,1 " " _I Genesis LED clear strobes and horn-strobes may be set for 15, �ti��' 4-5/e' 30, or 75 candela output.The output settingis changed bysimply }'l 11111111.M11111(11.75 cm) p P 9 P Y 1 removing the cover and sliding the candela switch to the desired h 1 =.��M= I setting.The device does not have to be removed from the wall OP .F„�' to change the output setting.The setting remains visible through ,_. i p re a small window on the left hand side of the device after the cover is closed. T3 temporal horn,high dB E( T3 temporal horn,low dB Constant horn,high dB G1T Trim Ring Constant horn,low dB 9/16^ (1.43 cm) 7^ I WI 11 (12.7 cm) - ���� ei I�1 J LaI 75 candela i _I%������' '� 30 candela I 15 candela f ��O 5-7/8' ' -- , ' (14.92 cm) Operating current Horns Strobes Sound 18 to 33 16 to 33 Strobe 16 to 33 16 to 33 • J setting VDC VFWR setting VDC VFWR \I r- C-LOW 13 mA 15 mA _ 15,30,75 24 mA 32 mA C-HIGH 23 mA 29 mA T-LOW 13 mA 15 mA T-HIGH 23 mA 29 mA Diagnostics Horn-Strobes !!!i Strobe Sound setting 16 to 33 VDC 16 to 33 VFWR pri setting 5,30, 75 C-Low,T Low35 mA43 mA C-High,T High 45 mA 55 mA r113 . I .c,-),,y s'11111 all •!• �+'. Test points indicated above are used to validate the Notification Appliance Circuit and verify device function. Page 3 of 8 E85001-0667 Issue 1 Sound Output Light Distribution Reverberant dBA(UL 464) Horizontal Left t0 0 5 10 15 Horizontal Right Sound setting Horn Horn-strobe 2025 20 15 20 25 30 C-LOW 80 80 35 35 C-HIGH 86 86 40 10111111110 40 45 45 7� so LOW 80 80 50id* 50 7-HIGH 86 86 55 55 6555 70 70 Anechoic dBA(CAN/ULC-S525) '� $ 60 75 Sound seing Horn Hero-strobe 80a0 85 nt 2 85 C-LOW 86 86 ea1 � s0 C-HIGH 92 92T-LOW 86 86 10 T-HIGH 92 9215 zo 25 35 Sound pattern(ULC) 30 Axis Angle Lthance of detput Nig40 .--_-- 45°and 115° 3 dBA 50as Horizontal 5°and 130° -6 dBA 55 60 Vertical 65'and 135° -3 dBA 70 65 75 Vertical Bottom 45°and 140° -6 dBA 90 S5 8° Measured UL Minumum Specifications Operating voltage 16 to 33 VDC,16 to 33 VLWR P 9 9 Horn signal type Constant or T3 temporal Light output 15,30,or 75 candela Strobe flash rate 1 fps(flash per second)approx. 20 0 max.between any two devices. Synchronization (To determine allowed wire resistance,refer to these specifications, and the specifications for the synchronized signal source.) Synchronization sources EDWARDS CC Series Signal Modules,Booster and Auxiliary Power Supplies, and Intelligent and Conventional Control Panels Wire size 12 to 18 AWG(0.75 to 2.50 mm°) Dimensions(WxHxD) 3 x 4-5/8 x 1-1/8 in.(7.62 x 11.75 x 2.86 cm) Strobe-to-box -0.71 inches(-1.8 cm) center offset Compatible electrical boxes[1] 1-gang,2-gang,4-inch octagon.4 inch square Trim rings G1TR,G1TW-Dimensions 5 x 5-7 x 9/16 in.(12.7 x 14 92 x 1.43 cm) Agency Listings FCC,ICC,UL1971, UL1638,UL464,CSFM (All models comply with ADA code of federal regulation Chapter 28 Part 36 final rule) Operating environment Temperature 32 to 122°F(0 to 50°C) Relative humidity 0 to 93%noncondensing [1]Electrical boxes must be at least'.-1/2 in.(3.8' cm)deep.Electrical boxes greater than three inches wide require a trim ring. Page 4 of 6 E85001-0667 Issue 1 • Ordering Information Notification Appliances Color Marking Replacement Appliance Covers Color Marking G1ARF Red FIRE G1ARA-CVR Red ALERT G1ARF-FR Red FEU G1ARF CVR Red FIRE G1ARF-Fit-CVR Red FEU G1ARF-SP Red FUEGO II G1ARF-SP-CVR Red FUEGO G1ARN Red None G1ARN-CVR Red None G1AWF White FIRE G1AWA-CVR White ALERT Horns Selectable G1AWF-FR White FEU Horn G1AWF-CVR White FIRE High/lowdB GIAWF SP White FUEGO Covers G1AWF-FR-CVR White FEU G1AWF-SP-CVR White FUEGO G1AWN White None G1AWN CVR White None G1VRF Red FIRE G1VRA-CVR Red ALERT G1VRF-FR. ... .._ Red FEU GIVRP-CVR Red FIRE G1VRF-SP Red FUEGO G1VRF-FR-CVR Red FEU r G1VRN Red NoneF G1VRF-SCVRP-CVR RedRed NoUEGOne "� G1VWA' White ALERT 15 G1VRN- G1VWA-CVR White ALERT Strobes G1VWF White FIRE G1VWF-CVR White FIRE Selectable Strobe G1 WVF-FR White FEU Covers 15,30,75 cd --- ---- -----. __._. GIVWF FR-CVR White FEU G1VWF-SP White FUEGO G1VWF-SP-CVR White FUEGO GlVWN White None G1VWN-CVR White None GIAVRF Red FIRE GIAVRA-CVR Red ALERT G1AVRF-CVR Red FIRE G1AVRF-FR Red FEU G1AVRF-FR-CVR Red FEU ii., G1AVRF-SP Red FUEGO G1AVRF-SP-CVR Red FUEGO G1AVRN Red None GIAVRN-CVR Red None G1AVWF White FIRE GIAVWA-CVR bVhile ALERT Horn-strobes --- — --- G1AVWF-CVR White FIRE Selectable GIAVWF FR While FEU Horn-strobe 15.30,75 cd, -- ---- -- ... Covers G1 AVWF-FR-CVR White FEU HlghlbwdB G1AVWF SP White FUEGO GIAVWF-SP-CVR White FUEGO GIAVWN White None G1AVWN-CVR White None Accessories 0 GITR Trim ring,G1 Series,red T-.. G1TW Trim ring,G1 Series,white 27193-11 One-gang surface mount box,red 27193-16 One-gang surface mount box,white Model Number Syntax, Appliances Model Number Syntax, Replacement Covers I —Genesis LED Series Genesis LED Series GI=Wall mount appliances GI=Wall mount appliances Housing Color r Housing Color R=Red R=Red W=White W=White 1 I Cover G1IAVRF Housing Marking G1AVRF-CVR Designation I - I N=None *ALERT Marking L F-F-FR=FUEGO=FEU available on white YI I Cover Marking strobe model with L N=None Functions F=FIRE clear lens only. Functions F-FR=FEU A=Horn only A=ALERT' See replacement A=Horn only F-SP=FUEGO V=Strobe only covers for more V=Strobe only F=FIRE AV=Horn-Strobe options. AV=Horn-Strobe A=ALERT Page 5 of a E85001 -0667 Issue 1 ED ARCS Contact us... Email: edwards.fire@fs.utc.com Web: edwerds-fire.com 1016 Corporate Park Drive Mebane,NC 27302 EDWARDS is a registered mark in the United States and other countries. ©2018 United Technologies Corporation. All rights reserved. 0 Page 6 of 6 E85001 -0667 m Issue 1 Strobes,Horns, Bells,Chimes EDWARDS • At Genesis LED `� GC Series • -�n Ceiling Mount 410 ~! \C\___ . . . . 4. Notification Devices ••�'••••� a ,) ••••.•.••' c• 4L US 0 • - S218, k S5389 y �, a fC CO)mmis leer Overview Standard Features Genesis LED GC Series horns and LED strobes feature a sleek • High Performance LED Strobe Technology low profile design and energy-efficient technology that makes -Ultra low device current consumption allows: them less expensive to install and operate by reducing overhead. -More devices per circuit High performance LEDs require fewer power supplies, backup -Ability to use lower gauge wire power,and batteries.These new appliances are designed with, -Longer wire runs energy-efficiency,and life safety in mind. -Fewer booster power supplies -Genesis LED GC Series uses high efficiency optics,combined High -Selecttableable ncy optics 15,30, 75, or 115 cd light output with patented electronics,to deliver a highly controlled and -LED devices may be mixed with legacy Xenon strobes efficiently focused light distribution pattern in exchange for lower current requirements.Strobes feature field-selectable • Efficient Audible Output 15,30,75,or 115 cd light output. -Selectable high or low dB horn output -Selectable temporal or steady horn output Compared with Xenon-type strobes,Genesis LED GC Series -Improved audio frequency range for better wall penetration appliances need fewer power supplies and often smaller wire gauge,which lightens conduit requirements.They are also • Low-profile Design backwards compatible with legacy strobes,so there's no need to -Ultra-slim...protrudes about 1.5"from the mounting surface replace all your existing devices to upgrade to new LED technology. -Attractive appearance... no visible mounting screws In fact,GC strobes can be mixed on the same circuit and used in • Multiple"FIRE"Marking Options the same field of view as Xenon-based strobes.This makes Genesis -Order English, French, Spanish or no FIRE markings LED GC Series ideal for new installations and retrofits alike. -Change markings at any time with replaceable Field-configurable sound output levels provide the flexibility quick-swap covers 11 modern life safety projects demand,while the Genesis LED • Easy to Install control protocol keeps multiple strobes on compatible NAC -Pre-install and pre-wire with convenient universal room circuits synchronized to well within NFPA 72 requirements.y side wiring plate -Check electrical continuity on room side wiringplate with Serviceability is another area where GC Series appliances shine. The universal room side wiring plate allows for pre-installation included diagnostics check bar and electrical wiring as well as checking continuity with the -Diagnostics port streamlines device circuit testing included diagnostics check bar.GC Series devices can then be -Fits 1-gang, 2-gang,4-inch octagon,and 4-inch square easily snapped into place with the confidence of knowing the electrical boxes wiring is correct.The innovative under-cover diagnostic test points -Optional red and white trim plates available provide easy access to device circuit testing while mounted. -Slide switches for field configuration -12 to 18 AWG in-out screw terminals for quick wiring Page t of 6 E85001-1021 Issue 1.1 Application Genesis LED GC Series horns, strobes,and horn-strobes mount Strobes to any standard one-gang,two-gang,4-inch octagon,and 4-inch square electrical box.Matching optional GCT trim rings are available Genesis GC Series strobes are UL 1971-listed for use indoors to cover oversized openings.Optional color matched double-gang as ceiling-mounted public-mode notification appliances for the surface boxes are also available.Genesis LED GC series are listed to hearing impaired. Prevailing codes require strobes to be used be both wall mounted or ceiling mounted. where ambient noise conditions exceed 105 dBA(87 dBA in Canada),where occupants use hearing protection,and in areas of public accommodation as defined in the Americans with (1) /% 'O Disabilities Act. \ O Synchronization is important in order to avoid triggering seizures in people with photosensitive epilepsy.All Genesis strobes exceed ��. UL synchronization requirements(within 10 milliseconds over a 'vl two-hour period)when used with a synchronization source.See (2)\ I I the specifications table for a list of compatible sources. i Horns /� 1, Genesis horn output reaches as high as 92 dBA and features an e — _ improved audio frequency range compared with other Genesis I I horns.This results in excellent sound penetration through walls and a clear warning of danger.Horn only models may be configured for (3) i +-/ V I either coded or non-coded notification appliance circuits.They can \ 1�1 also be set for high or low dBA output.This setting reduces horn I!"70. J,jam` �0 output by about 6 dBA. r '.��"�� -. The suggested sound pressure level for each signaling zone used (4)A with alarm signals is at least 15 dBA above the average ambient (5) sound level,or 5 dBA above the maximum sound level having a \ duration of at least 60 seconds,whichever is greater.These values are measured at five feet(1.5 m)above the floor.The average � I, ►jj - ambient sound level is A-weighted,fast response sound pressure \��`� ��/(1 measured over a 24-hour period. '� Doubling the distance from the signal to the ear will theoretically ` . ` result in a 6 dBA reduction of the received sound pressure level. (1)Elect ica Box The actual effect depends on the acoustic environment in the space. (3)WiringTrim Plate e(required,pa (3) plate(required,ordered separately) A 3 dBA difference represents a barely noticeable change in volume. (4)Machine screw(2X,supplied with wiring plate) (5)GC signaling appliance Installation Genesis GC horns and strobes mount to the required GP10 room side wiring plate.The GP10 mounting plate is ordered separately Wiring from the GC device in packs of 10 for convenient pre-installing and pre-wiring.The device can be removed easily from the room side wiring plate by pushing up with a screwdriver.The cover can also be removed from the device easily with a screwdriver to access the I,G o 0 0 O light and sound output settings and a diagnostics test port for voltage testing. 0 0 Horn/strobe + -I-Horn/strobe circuit in - 1 1 tl 1 - circuit out Removing Cover Removing Device (signal polarity ):�i--a5-aoiolol shown in the . s���)IC•fJl��.�IQIQ ¢ active condition) p - — - - -q• ___ t,p]�i�i,�i�u �9lL,.11i �Shorting Clip hiI = �� �e� ao� ' '' mof iila iri �\ y II �1I j ellIMINIMMIIIM Qj=,! I ., '.fir l ems .ao ,1 . X''s Page 2 of 6 E85001 -1021 Issue 1.1 Dimensions Field Configuration GC Notification Appliances Temporal horn and horn-strobe models are factory set to sound in e2° a three-pulse temporal pattern. By sliding the tone selector switch, 1.(4.62 cm) s.a° horn only models may be configured for constant horn output that (17.27 cm) — can be coded at precise intervals by EDWARDS control panels and control modules. 1 i Note:Temporal 3 coding is the required output for fire notification devices per NFPA 72.Any device coding other than temporal 3 is at the discretion and approval of the local authority having I_ jurisdiction(AHJ). • a o o°o° 0 no°,000.7,41 �i� da !�p Horns and horn-strobes are factory set for high dB output. Low loll: ( >o° dB output may be selected by sliding the tone selector switch. IIIIV h oo o'o°o‘ This reduces the output by about 6 dBA. _ �. No5.7.0.072.°700 � Genesis LED clear strobes and horn-strobes may be set for 15, II30, 75, or 115 candela output.The output setting is changed by � simply removing the cover and sliding the candela switch to the � Tji", desired setting.The device does not have to be removed from the wall to change the output setting.The setting remains visible through a small window on the device after the cover is closed. GCT Trim Plate(optional) Light and Sound Output Settings o�e�m) 106 -. 11... ...F. (26.92 cm) /ll ^� Wii (1) IGH (2) , j'I" H (4) O°° ° °� , /*1 ° ° /i.��-ow .. / / "mks \\� (5) s/ �\ (1)Constant,low dB ' /� ��ft (6)(2)Constant,high dB �__. 0 )1) d 'i�(3)T3 tem oral,low dB 1 �� (7) (4)T3 temporal,high dB �\ ���/ (8) (5)115 candela \', ••ZI`s� �,',C�/ (6)75 candela �'Nl��.r`����f/ `` 1�f (7)30 candela \ _� (8)15 candela �� Diagnostics Operating current (4. vow � i Horns Strobes /♦ 1. I♦ Sound 16 to 33 16 to 33 Strobe 16 to 33 16 to 33 IIr i setting VDC VFWR setting VDC VFWR Flit(A 5rL , , li' C Low 20 mA 25 mA 15 30, 35 mA 45 mA T-Low 75,115 \,�I\ �`�i//' ` C-High, �I/i `al T-High 30 mA 40 mA -, 9 5, O Horn-Strobes Test points indicated — — Strobe ' above are used to validate "ft........... setting Sound setting 16 to 33 VDC 16 to 33 VFWR the Notification Appliance 15,30, C-Low,T-Low 50 mA 60 mA Circuit and verify device function. 75, 115 C-High,T-High 60 mA 75 mA Page 3 of 8 E85001-1 021 Issue 1.1 Sound Output Light Distribution Horn&Horn-Strobe Horizontal Left 25 20 15 1° 250 ID Horizontal 10 15 20 25 30 Horizontal Right Sound setting Reverberant Anechoic (UL454) (CAN/ULC-5925) 35 35 C Low,T-Low 80 dBA 86 dBA 40 zoo 40 45 45 C High,T-High 86 dBA 92 dBA 50 56 55 ' -• 55 60 60 65 ' , 65 70 100 F - 70 75 _ 60 w v�� 75 Sound pattern—Horn Models(ULC) 80 `�' ao Axi,. An. ,dBA) es _--1 rirriall 855 Horizontal 115 and Sb 03 3 85 ---r _ 85 Vertical 125 and 50 91 7 so E— 1 '-�)60 ' 80 70 1,, t.. 70 65 r / 5 60 C✓ 75 Sound pattern—Horn-Strobe Models(ULC) 5550 ���, 505s 45 i A \ 46 Axis Angle(3 p1rt(dBA) 35 ' .<75 ° \+� 30 Vertical Bottom 145 and 35 93.0 _ 30 2525 Horizontal 155 and 35 90.8 20 10 5 s ° 20 135 and 35 92.0 Vertical 155 and 25 85.4 Measured — — — UL Minumum Specifications Operating voltage 16 to 33 VDC, 16 to 33 VFWR Horn signal type Constant or TC3 temporal Light output 15,30, 75,or 115 candela Strobe flash rate 1 fps(flash per second)approx. Synchronization 20 0 max.between any two devices.To determine allowed wire resistance,refer to these specifications,and the specifications for the synchronized signal source. Synchronization Sources Edwards CC Series Signal Modules, Booster and Auxiliary Power Supplies, Intelligent and Conventional Control Panels Wire sire 12 to 18 AWG(0.75 to 2.50 mm3) Mounting Wall or Ceiling mount Dimensions(0 x D) 6.8 x 1.82 in.(17.27 x 4.62 cm) Strobe-to box center offset -1.70 inches(-4.32 cm) Compatible electrical boxes[11 1-gang,2 gang.4-inch octagon,4-inch square Trim plates GCTR,GCTW 10.6 x 0.3 in.(26.92 x 0.76 cm) Operating environment Temperature 32 to 122°F(0 to 50°C) Relative humidity 0 to 93%noncondensing Storage Temperature -40 to 158 F(-40 to 70 C) 11]Electrical boxes must be at least 1-1/2 in.(3.81 cm)deep. Page Sole E85001 -1021 issue 1.1 Ordering Information Notification Appliances Color Marking Replacement Appliance Covers Color Marking GCARF Red FIRE GCARA-CVR Red ALERT GCARF-FR Red FEU GCARF-CVR Red FIRE GCARF-FR-CVR Red FEU GCARF-SP Red FUEGO GCARF-SP-CVR Red FUEGO `r10 GCARN Red None GCARN-CVR Red None GCAWF White FIRE GCAWA-CVR White ALERT Horns GCAWF-FR White FEU Horn GCAWF-CVR White FIRE Covers GCAWF-FR-CVR White FEU GCAWF-SP White FUEGO GCAWF-SP-CVR White FUEGO GCAWN While None GCAWN-CVR White None GCVRF Red FIRE GCVRA-CVR Red ALERT GCVRF-FR Red FEU GCVRF-CVR Red FIRE GCVRF-SP Red FUEGO ■A`. GCVRF-FR-CVR Red FEU f GCVRN Red None . ■ GCVRF-SP-CVR Red FUEGO k. GCVRN-CVR Red None GCVWF White FIRE ■' Strobes GCVWF FR White FEU GCVWA-CVR White ALERT Strobe GCVWF-CVR White FIRE GCVWF-SP White FUEGO Covers GCVWF FR-CVR White FEU GCVWN White None GCVWF-SP-CVR White FUEGO GCAWN-CVR White None GCAVRF Red FIRE GCAVRF-FR Red FEU GCAVRA-CVR Red ALERT GCAVRF CVR Red FIRE GCAVRF SP Red FUEGO %g® GCAVRF-FR-CVR Red FEU FXRF GCAVRN Red None GCAVRF-SP-CVR Red FUEGO ^�T#�� GCAVWF White FIRE oa ` GCAVRN-CVR Red None Horn-strobes GCAVWF FR White FEU a GCAVWA-CVR White ALERT Horn-strobe GCAVWF-CVR White FIRE GCAVWF-SP White FUEGO Covers GCAVWF-FR-CVR White FEU GCAVWN White None GCAVWF-SP-CVR White FUEGO GCAVWN-CVR White None Accessories Room Side Wiring 1;;;I: GP10 Plate(required, cio GCTR red pTrimlate,GC Series, GCTW Trim plate,GC Series, • ordered separately) white - 27193-21 Two-gang surface 27193-26 Two-gang surface mount box,red mount box,white Model Number Syntax, Appliances Model Number Syntax, Replacement Covers Genesis Series GC=Ceiling mount appliances—Housing Color —Genesis Series GC=Ceiling mount appliances R=Red r Housing Color W=White R=Red W=White GCAVRF Housing Marking I I Cover N=None ALERT Marking GCAVRF-CVR Designation F-FR=FEU available on white I I 1—r. F-SP=FUEGO I I Cover Marking strobe model only. N=None Functions F=FIRE See replacement A=Horn only A=ALERT* covers for more Fu ions only F-FR A =FUEGO V=Strobe only options. V=Strobe onlyF=FIRE AV=Horn-Strobe AV=Horn-Strobe A=ALERT Page 5 of e E85001-1021 Issue 1.1 �DWARDS Contact us Phone: 800-655-4497(Option 4) Email: edwards.fireOcarrier.com WebsIto: edwardsfire$aferi.com 8985 Town Center Pkwy Bradenton,FL 34202 ©2020 Carrier All rights reserved. 0 Page 6 of 6 E85001-1021 Issue 1.1