Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
FFS20z1 -co OFFIGNIM el.6 "1117 " RECEIVED 1FFICE COPY SEP , u21 CITY OF TIGARD ti/6 3UILDING DIVISION Western States Fire Protection Co. A(Waif, Zai-e4 � Ptoizeteet POWERED BY API Group 17500 SW 65th Avenue Lake Oswego, OR 97035 Phone (503) 657-5155 Fax (503) 657-5182 Fire Protection Calculations Fred Shearer & Sons - Exterior Renovation 8015 SW Hunziker St. Tigard, OR 97223 WSFP Project #LG5726 Prepared by: Kevin Olson Designer ��p PRO Western States Fire Protection Co. /�� " I N- SS'' 17500 SW 65th Avenue �' F'P�O17 Lake Oswego, OR 97035 cr/ 80861 PE \r- `l Phone: (503) 330-0162 Digitally signed by Brandon Koonz \ OREGON Email: kevin.olson@wsfp.us ,. ' '< 9'�� �a� Web: www.wsfp.com 12 1- August 25, 2021 C . C . q4� EXPIRES: 6/30/2023 Water Data 1116 Western States 17500 SW 65th Avenue,Lake Oswego,OR 97035 Fire Protection Co. Phone:(503)657-5155•Fax:(503)657-5182 pzofece 9 .dauee awe puovto HYDRANT FLOW TEST REPORT PROJECT: Fred Shearer& Sons Exterior Renovation JOB NO: LG5726 LOCATION: 8015 SW Hunziker St. Tigard, OR 97223 DATE: 08/12/21 TIME: 9:30 am MAJOR CROSS STREETS: SW Hunziker St JURISDICTION: Tigard Water District TEST MADE BY: Kevin Olson, Yu Lee Han REPRESENTING: Western States Fire Protection WITNESSED BY: REPRESENTING: Tigard Water District PURPOSE OF TEST: Analysis of available water flow to design new sprinkler heads. Note: 4" Hose Monster w/pitotless nozzle. Calibrated gauge used for GPM. FLOW HYDRANTS A-0 A-1 A-1 B-2 C-1 C-2 SIZE NOZZLE-2.50/4.00 4" INCH PITOT READING 102 96 PSI DISCHARGE COEFFICIENT FLOW 2350 GPM ELEVATION FEET STATIC PRESSURE: 102 PSI STATIC HYDRANT ELEVATION: FEET RESIDUAL PRESSURE: 96 PSI TOTAL FLOW: 2350 GPM FLOW @ 20 PSI: 9659 GPM # I •; v Hydrant A-0 for Flow saL mir Hydrant A-1 for static/ Residual Pressure g ■ _ , ,m i. _. __Fire Hydrant Test Te E u I • zma m am m mnm +m .o MM REMARKS: Hydraulic Calculations Job Number:LG5726 Id Hydraulic Overview Report Description:Light Hazard(FS&S-East Canopy) Job Job Number Oe,on Engineer LG5726 Kevin Olson Plane - -.. FA% FS&S Exterior Renovation 503-330-0162 Am.t Stele GrlBubbNllar+e Plumber 6015 SW Hunziker St. 104570 Maros s NO Tigard,OR 97223 City of Tigard Adem.e 3 Job saeBurunp FS&S Office System berm &eO o,APPfufnn 0.100gpm/fF 1500.00ft'(Actual 465.28ft') not oebwd.ro SoMdo,one Xw SN.n 5.6 K-Factor 14.82 at 7.000 100.00 Over Pr SIAMbr Number Or Spnlaae MOOR! Mmb'OfSptNrt Cwewe 130.00ft' 6 0 S.*.eP ve Orrrrq Sy.--0erw4 78.068 95.36 Total Demand —- —_ - - --- P2Mve Result 195.36 @ 78.068 +23.872(23.4%) Supplies Check Point Gauges Node Name Flowlgpmj Hose Flowfdpm) Slatic(psit Residual(osit Identifier Pressureipslj K-Fector(Kl Flow(gpmt 1 Water Supply 2350.00 100.00 102.000 96.000 LG5726-FS&S Exterior Canopy Water Supply at Node 1 (2350.00,100.00.102.000,96.000) 150 135 120 105 tatic Pressure 102.000 90 -0.00 @ 96.000 a 5.36 @ 78.068 75 195.36 with hose streams N a 60 45 ystem demand curve 30 15 • 0 Ill/llll1111111111111111111111IIII II 111111111 111111111 111111111 25V935118°°2250 2700 3150 3600 4050 4500 _....._..___.._--.__. Water flow,gpm LM ®M.E.P.CAD,Inc. ®AutoSPRINK 2019 v15.1.20.0 8/25/2021 3:39:46PM Page 1 Hydraulic Summary Job Number LG5726 � 5 Report Description:Light Hazard(FS&S-East Canopy) Job Job'Amber Design Engineer LG5726 Kevin Olson Job Nerm: State Granmbmplmm.latmea, FS&S Exterior Renovation 104570 Address l AHJ 8015 SW Hunziker St. City of Tigard Address: Jab 59YRW0y _ Tigard,OR 97223 FS&S Office Address 3 D,w:s, LG5726-FS&S Exterior Canopy System _ Remote Area(s) Moot Demanding Sprinkler Data Oawpemry .be soTA 5.6 K-Factor 14.82 at 7.000 Light Hazard Hose Marano,Al Source Density Ante or Wagon 100.00 0.100gpm/RX 1500.00ft'(Actual 465.28ft) Rddnional Host Supplies Number a SprHkbre Gambled Weber Of Wales CMNMed Covemd.Per SpAtor Node Flow(aoml 6 0 130.00f Nrl0Peek Results:Peeue For Remote MO)Mpcerrt To Most Rarola Ma Toot Ross Stream 100.00 Syseem MOO Demand Total Water Requited(Including Hose Nkmwce) 95.36 195.36 MmM1nun Prepare UnbSnce In Loops 0.000 MCLLnun VNONy Mass OrpM 16.73 between nodes 13 and 14 Mainurn Wank Under Ogund volume 4pWy e1 Wet Pips VOL...cepacty m My PIN. 453.68ga1 Supplies Hose Flow Static Residual Flow Available Total Demand Required Safety Margin Node Name (gpm) (psi) (psi) ;gpm) (psi) @ (gpm) (psi) (psi) 1_ Water Supply 100.00 102.000 96.000 2350.00 101.940 I 195.36 78.068 23.872 Contractor '- Contractor Number Centex Ne o Coma TNs LG5726 Kevin Olson Designer/PM Name of Common: Awe Epernbn Western States Fire Protection ' 503-657-5155 Address I FAX 17500 SW 65th Ave. Address2 E_ma,l Lake Oswego,OR 97035 kevin.olson@wsfp.us Address 66,©M.E.P.CAD,Inc. AutoSPRINK 2019 v15.1.20.0 8/25/2021 3:39:49PM Page 2 +' ; H;ydraulrc Graph Job Number.LG5726 Report Description:Light Hazard(FS&S-East Canopy) Water Supply at Node 1 150 135 120 105 -Static Pressure 102.000 350.00 96.000 90 a -95.36 Y 78.068 1i i m 75 195.36 with hose streams z W o_ 60 45 S/stem demand curve 30 15 3 0 1111111111111111111111 111111111 111111111 111111111 111111111 11111 II I L 1 I I 1 1 1 1 1 1 111111111 0 900 1350 1800 2250 2700 3150 3600 4050 4500 Water flow,gpm Nydrsulk Gres. Water Supply at Node 1 Stern:Prue — --- _ 102.000 Meekpet 96.000 n 2350.00 Areiede Pressure MU.of Test 101.940 @ 195.36 System p.iem 78.068 @ 95.36 .wmm Pound(Including Hose No.....at Sew* 78.068 @ 195.36 ©M.E.P.CAD,Inc. 1-4 AutoSPRINK 2019 v15.1.20.0 8/25/2021 3:39:51PM Page 3 e Summary Of Outflowing Devices ` Jop Number LG5726 Report Description:Light Hazard(FS&S-East tanopy) Actual Flow Minimum Flow K-Factor Pressure Device (gpm) (gpm) (K) (psi) 40, Sprinkler 101 14.82 10.93 5.8 7.000 Sprinkler 102 14.95 11.62 5.6 7.127 Sprinkler 103 15.45 11.62 5.6 7.615 Sprinkler 104 15.68 10.93 5.6 7.835 Sprinkler 105 15.82 10.93 5.6 7.976 Sprinkler 106 18.65 10.80 5.6 11.096 14> Most Demanding Sprinkler Data G„ ®M.E.P.CAD,Inc. ill AutoSPRINK 2019 v15.1.20.0 8/25/2021 3:39:53PM Page 4 kli Hydraulic Analysis Job Number:LG5726 Report Description:Light Hazard(FS&S-East Canopy) Pipe Type Diameter Flow _ Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length = Route 1 BL 1.4420 14.82 2.91 120 0.015862 8'-0 Pf 0.127 101 9'-0'% 14.82 5.6 7.000 Sprinkler Pe 102 9'-0% 7.127 8'-0 Pv BL 1.4420 29.77 5.85 120 0.057680 8'-S% Pt 0.488 102 9'-DY. 14.95 5.6 7.127 Sprinkler Pe 103 9'-0Y. 7.615 8'-514 Pv BL 1.4420 45.22 8.88 120 0.124979 2'-1% Pf 1.192 103 9'-0'/. 15.45 5.6 7.615 Sprinkler, 7'-5% Pe 15 9'-014 8.806 T(7'-5%) 9'-6%Pv CM 1.4420 76.71 15.07 120 0.332253 8'-0% Pf 2.677 15 9'-0% 31.49 8.806 Flow(q)from Route 2 Pe 0.425 14 8'-0% 11.908 8-0'h Pv CM 1.4420 95.36 18.73 120 0.496993 22'-9% Pf 20.574 14 8'-0'% 18.65 11.908 Flow(q)from Route 3 18'-7 Pe -0.413 13 9'-0 32.070 5E(3'-8%) 41'-4%Pv CM 1.6820 95.36 13.77 120 0.234822 34'-0Y. Pf 13.878 13 9'-0 32.070 24'-9 Pe 11 9'-0 45.947 5E(4•-11+%) 59'-1% Pv CM 1.6100 95.36 15.03 120 0.290582 19'-0% Pf 15.115 11 9'-0 45.947 33'-0 Pe 0.397 10 8'-1 61.460 T(6'-0),CV(9'-0),2E(4'-0),BV, 52.-0% Pv mecT(8'-0) CM 6.0650 95.36 1.06 120 0.000455 2'-7'% Pf 10.001 10 8'-1 61.460 Pe 3.342 5 0'-4%z 74.803 BFP(-10.000) 2'-7Y•Pv FR 6.2800 95.36 0.99 140 0.000289 164'-4% Pf 0.067 5 0'-4% 74.803 69'-4 Pe 3.197 1 -7'-0 78.068 E(22'-0%),T(47'-3%),S 233'-8% Pv 100.00 Hose Allowance At Source 1 195.36 Si Route 2 BL 1.4420 15.68 3.08 120 0.017605 8'-0 Pf 0.141 104 9'-0'/. 15.68 5.6 7.835 Sprinkler Pe 105 9'-0% 7.976 8'-0 Pv BL 1.4420 31.49 6.19 120 0.063994 5'-6'% Pf 0.830 105 9'-0'/. 15.82 5.6 7.976 Sprinkler, 7'-5'% Pe 15 9'-0'/. 8.806 T(7'-5Y.) 12'-11%Pv OD Route 3 BL _ 1.0490 18.65 6.92 120 0.114390 2'-1'% Pf 0.813 106 8'-O% 18.65 5.6 11.096 Sprinkler, 5'-0 Pe 14 8'-0'/. 11.908 P0(5.-0) 7'-1% Pv Equivalent Pipe Lengths of Valves and Fittings(C=120 only) C Value Multiplier Actual Inside Diameter 4 el Value Of C 100 130 140 150 ( Schedule 40 Steel Pipe Inside Diameter ) =Factor Multiplying Factor 0.713 1.16 1.33 _ 1.51 EA,©M.E.P.CAD, Inc. AAutoSPRINK 2019 v15.1.20.0 8/25/2021 3:39:55PM Page 5 i�� Hydraulic Analysis 1 Job Number:LG5726 Report Description:Light Hazard(FS&S-East Canopy) Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length Pipe Type Legend Units Legend Fittings Legend AO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing DN Drain Dischar egpm BalV Ball Valve DR Drop 9 BFP Backflow Preventer DY Dynamic Velocity fps BV Butterfly Valve FM Feed Main Pressure psi C Cross Flow Turn 90° FR Feed Riser Length Foot cplg Coupling MS Miscellaneous Friction Loss psi/Foot Cr Cross Run OR Outrigger HWC Hazen-Williams Constant CV Check Valve RN Riser Nipple Pt Total pressure al a point in a pipe DelV Deluge Valve SP Sprig DPV Dry Pipe Valve ST Stand Pipe Pn Normal pressure at a point in a pipe E 90°Elbow UG Underground Pf Pressure loss due to friction between points EE 45°Elbow Pe Pressure due to elevation difference between indicated Eel 11W Elbow points Ee2 22Yz Elbow Pv Velocity pressure at a point in a pipe f Flow Device fd Flex Drop FDC Fire Department Connection fE 90°FireLock(TM)Elbow fEE 45°FireLock(TM)Elbow fig Flange FN Floating Node fT FireLock(TM)Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LIE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap k,©M.E.P.CAD,Inc. . AutoSPRINK 2019 v15.1.20.0 8/25/2021 3:39:55PM Page 6 +-I'ii, Hydraulic Overview ` Job Number:LG5726 Report Description:Light Hazard(FS&S-South Canopy) Job Joh Weber Oesgn Engineer LG5726 Kevin Olson - IS Na,.: — Phone . - _ FAX FS&S Exterior Renovation 503-330-0162 Adorwt I Sete cerHAetion kerse Number 8015 SW Hunziker St. 104570 AO'Jtw I AHl Tigard,OR 97223 City of Tigard Andress 3 Job Sile?Buikig FS&S Office '..na System • ..::...,_ r...., _ hnsN Area of Applului 0.100gpmlft' 1500.00ft'(Actual 301.38ft2) Moat MnrdLB SpMlsr Dale lime Streams 5.6 K-Factor 16.46 at 8.638 100.00 Coverage Per Sprinkler pumper Of Spinners Cakolled Humber Of Spinners C&arl.d 225.00ft 4 0 sense PTW.Connor hid.Fret Osmod 65.555 66.60 TOIM Remand Pmure ReWt 166.60 Cry 65.555 +36.400(35.7%) Supplies Check Point Gauges Node Name Flow(opmt Hose Flowlooml Static(psit Reedual(psi) Identifier Pressure(psi( K-Factor(K( Flowfopm) 1 Water Supply 2350.00 100.00 102.000 96.000 LG5726-FS&S Exterior Canopy Water Supply at Node 1 (2350.00,100.00,102.000,96.000) 150 135 120 105--Static Pressure 102.000 90 _ - .2350.00 @ 96.000 4.1 75 366.60 @ 65.555 rjr e 60—166.60 with hose streams 45 =_System demand curve ( 30 - Lf l ,l 15 O q11111•11111111111111111111111111 111111111 111111111 111111111 111111111 IIIIII III 45i7935018002250 2700 3150 3600 4050 4500 Water flow,gpm Lk,©M.E.P.CAD,Inc. AutoSPRINK 2019 v15.1.20.0 8/25/2021 3:40:20PM Page 1 Hydraulic Summary JobNumberaG5726 Report Description:Light Hazard(FS&S-South Canopy) Job Job Number Design Engineer LG5726 Kevin Olson Job Neon: Sale C*HCS edLla l..weber FS&S Exterior Renovation 104570 AddesN AHI ---- ------ 8015 SW Hunziker St. City of Tigard Minas 2 Job Saebuidrg Tigard,OR 97223 FS&S Office Address 3 Drmrng N.m. LG5726-FS&S Exterior Canopy S -ern 3 Most Demanding SprOMer Dam CmrAralr Job a'� 5.6 K-Factor 16.46 at 8.638 Light Hazard Hose uwwana Al Scums panty an.ofApgkppn 100.00 0.1 oogpm/ft2 1500.00ft2(Actual 301.38ft2) AWM1Mal Hoge Supplies wmh.r Of Sprinklers CMabMd HM*'erpl Humes CMNMW Coercive PVSpdi]x Node Flow(gpm) 4 0 225.00fta AUSPeak Results:Pressure For Remote Nea(s)Mimb le Ts Mat RCMP Ma Right:65.555 Total Hose Streams 100.00 System Raw Demand Total WNr Rebored tlnck,lg Hose Aauwge) 66.60 166.60 wan..Prue.Unbalance In taupe 0.000 MWnum V.kOly More groorrd 13.08 between nodes 21 and 22 MUMIm Velocity Under Ground Vt.,.aap.ury al Wet Pipes Volume ap.0Sy of Dry Plpen 453.68ga1 Hose Flow Static Residual Flow Available Total Demand Required Safety Margin Node Name (gpm) (psi) (psi) @ (gpm) (psi) @ (gpm) (psi) (psi) 1 Water Supply 100.00 102.000 96.000 2350.00 101.955 166.60 65.555 36.400 Contractor 1111111111.11111111111 cono-.nor Dumber cmWcm Name Contact 110a LG5726 Kevin Olson Designer/PM Hams of Conbw3a: Phone E.lerldn Western States Fire Protection 503-657-5155 Pedro., FAD 17500 SW 65th Ave. Address 2 Em0I Lake Oswego,OR 97035 kevin.olson@wsfp.us Address Web-Sire �,®M.E.P.CAD,Inc. G4 AutoSPRINK 2019 v15-1.20.0 8/25/2021 3:40:23PM Page 2 111 Hydraulhc Graph Job Number:LG5726 Report Description:Light Hazard(FS&S-South Canopy) Water Supply at Node 1 150 135 120 105 Static Pressure 102.000 350.00 @ 96.000 90 6 75 (n iv a ® 66.60 T"65.555 166.60 with hose streams 60 45 —S stem demand curve 30 15 0 II Milli I I I I I I l 111 11 I I I I I I I I I 1 1 1 1 1 1 1 I I I I I I 1 1 1 1 I I 1 I 1 I 1 I 1 0450 90D 1350 1800 2250 2700 3150 3600 4050 4500 Water flow,gpm Hydraulic Graph Water Supply at Node 1 Blelle Pressure 102.000 Residual.Pressure 96.000 @ 2350.00 Avallade Pressure al Term of Teal 101.955 @ 166.60 snlemoernane 65.555 @ 66.60 snr.moananulmrWinglbsaaluwaouua 5ourwl —._.. 65.555 @ 166.60 M.E.P.CAD,Inc. 11 AutoSPRINK 2019 v15.1.20.0 8/25/2021 3:40:24PM Page 3 i�� Summary Of Outflowing Devices JogNumber.•LG5726 ® Report Description:Light Hazard(FS&S-South Canopy) Actual Flow Minimum Flow K-Factor Pressure Device (gpm) (gpm) (K) (psi) Sprinkler 201 16.74 3.90 5.6 8.933 Sprinkler 202 16.57 16.46 5.6 8.754 qt !pdnkler 203 16.46 16.46 5.6 8.638 Sprinkler 204 16.84 3.90 5.6 9.040 ♦ Most Demanding Sprinkler Data /�i ©M.E.P.CAD,Inc. li AutoSPRINK 2019 v15.1.20.0 8/25/2021 3:40:26PM Page 4 Hydraulic Analysis ` Job Number:LG5726 Report Description:Light Hazard(FS&S-South Canopy) Pipe Type Diameter _ Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length o Route 1 DY 1.0490 16.46 _6.11 120 0.090738 0'-0 Pf 2.631 203 10'-3 16.46 5.6 8.638 Sprinkler, 29'-0 Pe -0.072 25 10'-5 11.197 PO(5'-0),fd(24'-0) 29'-0 Pv BL 1.4420 33.30 6.54 120 0.070942 7-6% Pf 1.063 25 10'-5 16.84 11.197 Flow(q)from Route 4 7'-5'% Pe 22 10'-5 12.260 T(T-5Y,) 14'-11'/. Pv CM 1.4420 66.60 13.08 120 0.255824 5'-3'Y Pf 4.206 22 10'-5 33.31 12.260 Flow(q)from Route 2 11'-1% Pe 0.145 21 10'-1 16.611 3E(3'-8%) 16'-5Y.Pv CM 1.4420 38.45 7.55 120 0.092591 0'-5'% Pf 0.387 21 10'-1 16.611 3'-6Yz Pe 0.199 20 9'-7% 17.196 E(3'-8+%) 4'-2 Pv CM 1.4420 66.60 13.08 120 0.255824 52'4'% Pf 16.253 20 9'-7% 28.15 17.196 Flow(q)from Route 5 11'-1% Pe 0.271 12 9'-0 33.720 E(3'-8Y),PO(7'-5Y..) 63.-6'% Pv CM 1.6820 66.60 9.62 120 0.120873 33'-lOY. Pf 7.083 12 9'-0 33.720 24'-9 Pe 11 9'-0 40.803 5E(4'-11%) 58'-7/. Pv CM 1.6100 66.60 10.50 120 0.149575 19'-0% Pf 7.780 11 9'-0 40.803 33'-0 Pe 0.397 10 8'-1 48.961 T(8'-0),CV(9'-0),2E(4'-0),BV, 52'-0% Pv mecT(8'-0) CM 6.0650 66.60 0.74 120 0.000234 2'-7'% Pf 10.001 10 8'-1 48.981 Pe 3.342 5 0'4'% 62.323 BFP(-10.000) 2'-7'% Pv FR 6.2800 66.60 0.69 140 0.000149 164'-4% Pf 0.035 5 0'-4% 62.323 69'4 Pe 3.197 1 -7.-0 65.555 E(22'-0%),T(4T-3V.),S 233'-8'/ Pv 100.00 Hose Allowance At Source 1 166.60 w Route 2 DY 1.0490 16.57 6.15 120 0.091871 0'-0 Pf 2.664 202 10'-3 16.57 5.6 8.754 Sprinkler, 29'-0 Pe -0.072 23 10'-5 11.346 P0(5'-0),fd(24'-0) 29'-0 Pv BL 1.4420 33.31 6.54 120 0.070985 5'-5'/. Pf 0.914 23 10'-5 16.74 11.346 Flow(q)from Route 3 7'-5% Pe 22 10'-5 12.260 T(7'-5%) 12'-10'% Pv OD Route 3 BL 1.0490 16.74 6.21 120 0.093603 1'-9 Pf 3.720 201 7'-2 16.74 5.6 8.933 Sprinkler, 38'-0 Pe -1.409 24 10'-5 11244 2E(2'-0),T(5'-0),P0(5-0),fd(24' 39'-9 Pv -0) BL 1.4420 16.74 3.29 120 0.019875 5'-2 Pf 0.103 24 10'-5 11.244 Pe 23 10'-5 11.346 5'-2 Pv v Route 4 BL 1.0490 16.84 6.25 120 0.094640 1'-3 Pf 3.524 204 7'-0 16.84 5.6 9.040 Sprinkler, 36'-0 Pe -1.481 26 10'-5 11.083 E(2'-0),T(5'-0),PO(5'-0),fd(24'- 37'-3 Pv 0) BL 1.4420 16.84 3.31 120 0.020095 5'-8 Pf 0.114 26 10'-5 11.083 Pe 25 10'-5 11.197 5'-8 Pv o Route 5 DY 1.4420 28.15 5.53 120 0.052006 0'-0 Pt 0.387 21 10'-1 16.611 E(3'-8%) 7'-5'% Pe 0.199 20 9'-7'/ 17.196 E(3+-a%) 7'-5% Pv Equivalent Pipe Lengths of Valves and Fittings(C=120 only) ` C Value Multiplier Actual Inside Diameter a.e7 Value Of C 100 130 140 150 ( Schedule 40 Steel Pipe Inside Diameter ) =Factor Multiplying Factor 0.713 1.16 1.33 1.51 k,©M.E.P.CAD,Inc. 41AutoSPRINK 2019 v15.1.20.0 8/25/2021 3:40:28PM Page 5 Hydraulic Analysis Joh,Number:,Lc5726 • Report Description:Light Hazard(FS&S-South Canopy) • Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length Pipe Type Legend Units Legend Fittings Legend AO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flowgpm b Bushing DN Drain BalV Ball Valve DR Drop Discharge gpm BFP Backflow Preventer DY Dynamic Velocity fps BV Butterfly Valve FM Feed Main Pressure psi C Cross Flow Turn 90° FR Feed Riser Length Foot cplg Coupling MS Miscellaneous Friction Loss psi/Foot Cr Cross Run OR Outrigger HWC Hazen-Williams Constant CV Check Valve RN Riser Nipple Pt Total pressure at a point in a pipe DelV Deluge Valve SP Sprig DPV Dry Pipe Valve ST Stand Pipe Pn Normal pressure at a point in a pipe E 90°Elbow UG Underground Pf Pressure loss due to friction between points EE 45°Elbow Pe Pressure due to elevation difference between indicated Eel 11Y+°Elbow points Ee2 2216°Elbow Pv Velocity pressure at a point in a pipe Flow Device fd Flex Drop FDC Fire Department Connection fE 90°FireLock(TM)Elbow fEE 45°FireLock(TM)Elbow fig Flange FN Floating Node fT FireLock(TM)Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap • [4,©M.E.P.CAD,Inc. JAutoSPRINK 2019 v15.1.20.0 8/25/2021 3:40:28PM Page 6 RECEIVED CITY OF TIGARD BUILDING DIVISION Western States Fire Protection Co. 17500 SW 65th Ave. Lake Oswego, OR 97035 Phone (503) 657-5155 Fax (503) 657-5182 Fire Protection Product Data Sheets Fred Shearer & Sons Exterior Renovation 8015 SW Hunziker St. Tigard, OR 97223 WSFP Project #: LG5726 Prepared by: Kevin Olson Western States Fire Protection Co. Phone: (503) 330-0162 Email: kevin.olson@wsfp.us Web: www.wsfp.com Aug 25, 2021 Table of Contents 1 . Steel Pipe 2. Fittings and Couplings 3. Sprinkler Heads 4. Hangers 5. Valves 6. Antifreeze Solution Steel Pipe r Schedule 10 and Schedule 40 FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer Bull Moose Tube's Sch. 10 and Sch. 40 pipes are of quality pipe products. Our Schedule 10 and made to ASTM A135 and ASTM A795. These Schedule 40 are FM Approved and UL Listed (for U.S. products are typically supplied with our protective and Canada), even though these products do not coating but can be supplied without the coating so require separate approvals and listings. Bull Moose they can be hot-dip galvanized to meet FM Tube made the decision to have them approved and requirements for use in dry systems in accordance listed for your peace of mind. Our Sch. 10 and Sch. 40 with the zinc coating specifications of ASTM A795 or have been through the same rigorous testing as our ASTM A53. All Schedule 10 and Schedule 40 pipe other fine pipe products. has a pressure rating of 300 PSI. Schedule 10 Pipe Nominal Pipe Size(in) Nominal O.D. (in) Nominal I.D. (in) Weight/Ft Bundle Size 1 1.315 1.097 1.41 lbs/ft 91 1 1/4 1.660 1.442 1.81 lbs/ft 61 11/2 1.900 1.682 2.09 lbs/ft 61 2 2.375 2.157 2.64 lbs/ft 37 21/2 2.875 2.635 3.53 lbs/ft 30 3 3.500 3.260 4.34 lbs/ft 19 4 4.500 4.260 5.62 lbs/ft 19 Schedule 40 Pipe ce ' '` ` a',2 sue`0.' `::& , 4' .�"w' .r ": `+§ " ,- #r a.as m, r " r w,€ w r '+r. V:, t 6 I t a rq �� f i I'W cu r r' p ,f,.�ttt eo h»4 i(i a '} t a F� w�sn`�, «. JL.�1 �1&C�+si�.� ,`_�,.t , � u��r .ice TIP " ' � ,W�M�«c���. . �..a�k€� r�L',�:,3�' ? k�+��sF'r..� La 1 1.315 1.049 1.68 lbs/ft 70 11/4 1.660 1.380 2.27 lbs/ft 51 11/2 1.900 1.610 2.72 lbs/ft 44 2 2.375 2.067 3.66 lbs/ft 30 21/2 2.875 2.468 5.80 lbs/ft 30 3 3.500 3.068 7.58 lbs/ft 19 4 4.500 4.026 10.80 lbs/ft 19 PIPE PREPARATION For proper operation,all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket,pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale,dirt,chips,grease,and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also,check the manufacturer's instructions for the specific fitting used. i(No (1 1819 Clarkson Road For additional information, �M�+/1 Chesterfield,MO 63017 contact your salesperson COus ke1 RI n t MOOSE TUBE COMPANY (800)325-4467 today at(800)325-4467 or USIED ;— FAX:(636)537-2645 (636)537-2600 in the USA, www.bullmoosetube.com or from Canada41t A(CAPAROcompany e-mail; sales@bullmoosetube.com call(800)882-4666 APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 12/09 Fittings and Couplings III PICTORIAL TABLE OF CONTENTS II, Cast Iron CAST IRON THREADED FITTINGS - CLASS 125 (STANDARD) r AiIIIIII dir at i.' iiirg.„, Fig. 351 Fig.371 f Fig.356& 356R i Fig.356A Fig.352 90°Elbow 90'Elbow-Flange&Screw t 45'Elbow t 221/2°Street Elbow 90°Reducing Elbow Size Range:'/"thru 8" Size Range:21/z'thru 6" (Straight&Reducing) Size Range: 3/4"thru 21/2" Size Range: 1/2'x 1/4"thru 6"x 5" Page 38 Page 38 Size Range: '14'thru 8"(Straight) f Page 39 Page 40 1'x'/2'(Reducing) Page 39 i 411. , I Fig.358 FIg.359 Fig. 360 Fig. 361 Fig.366 Tee Reducing Tee Cross Cross Reducing Screwed Hex Coupling Size Range:'/;'thru 8' Size Range: Size Range:'/z'thru 6" Size Range: Size:1" Page41 1/ex1/2"X1/"ihru6"x6'x5' , Page 46 1"x1"x3/;x3/:thu4"x4"x2"x2' Page 47 Page 41 -45 i Page 46 NIP I c Illr I il• Fig. 487 Fig.367 Fig. 368 Fig. 383 Fig.385 Flanged Union Gasket Type Concentric Reducer Eccentric Reducer Hex Bushing Face Bushing Size Range:'/2 thru 8° Size Range:'/4"x'12"thru 8'x 6" Size Range:3/4"x'/2"thru 6'x 4' 1 Size Range:1'/z'x'/;Ihru 10'x 8" Size Range:3'x 2'thru 4'x 3' Page 47 Page 48 Page 49 Page 50-51 Page 51 I I I 0 Fig. 387 I Fig.388 Fig. 389 1FIg. 380 Fig.390 Square Head Plugs,Cored t Square Head Plugs,Solid d Bar Plugs,Cored a Bar Plugs,Solid r Countersunk Plugs Size Range:3A"thru 4 Size Range:lb"thru 3'/2" ' Size Range:4"thru 8' # Size Range:4"thru 8' Size Range:1'thru 4" Page 52 L Page 52 Page 52 Page 52 Page 52 11. C3111 , Fig. 381 Fig.370 Cap i Locknut Size Range:21/2'thru 8' Size Range:21/2'thru 4' Page 52 Page 53 CAST IRON THREADED FITTINGS - CLASS 250 (EXTRA HEAVY do ,, Fig.421 ig. 424 Fig. - i Fig. 426 90°Elbow tt 45°Elbow I Tee Reducing Tee , Size t..•; " t 4 ru 3 Size Range: thru 21/2 Size Range: V4"thru 4' Size Range: 3 V2'thru 2'x 2"x 1'/z" r Page 53 iPage 53 Page 54 Page ° 8 www.anvilinttl.com Z / M/114 PF-11.10 MP Victaulic® FireLockTM Installation-ReadyTM Rigid Couplings tal�liC J,c Ii Style 009N and Style 109 10.64 Patented Patented 1.0 PRODUCT DESCRIPTION Available Sizes • Style 009N: 11/4 — 12"/DN32 — DN300 • Style 109: 114—4"/DN32 — DN100 Pipe Material • Schedule 10, Schedule 40 or specialty carbon steel pipe listed in Section 5. For use with alternative materials and wall thicknesses please contact Victaulic • For exceptions reference section 6.0 Notifications Maximum Working Pressure • Up to 365 psi/2517 kPa Function • Joins carbon steel pipe with grooved ends conforming to publication 25.01 • Provides a rigid pipe joint designed to restrict axial or angular movement 2.0 CERTIFICATION/LISTINGS c AL n ® f(LPCLi IIS C E LISTED 104-1a/36 EN 10311 Regulation (EU) No.305/2011 ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved j Date victaulic.com 10.64 7072 Rev 0 Updated 02/2021 ©2021 Victaulic Company.At rights reserved. 1 ictaulic` victaulic.com • -_ _- S. • 3.0 SPECIFICATIONS- MATERIAL Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) ❑ Orange enamel (North America, Asia Pacific) ❑ Red enamel (Europe) ❑ Optional for Style OO9N: Hot Dipped Galvanized per ASTM GasIWpecify choice) ❑ Grade "E" EPDM (Type A) Vic.PIusTM Pre-lubricated Gasket EPDM (Violet Color Code). Applicable for wet and dry (oil-free air)fire protection systems only. Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems at-40°F/-40°C and above. Not compatible for use with hot water services or steam services. NOTES • Reference should always be made to publication I-100,Victaulic Field Installation Handbook for gasket lubrication instructions. • Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible.Reference should always be made to p 01,Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: (specify choice) Standard: Carbon steel oval neck track bolt(s) meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (M1O-M16) Class 8.8 (M2O and greater). Carbon steel hex nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial) and ASTM A563M Class 9 (metric). Track bolts and hex nuts are zinc electroplated per ASTM B633 Fe/Zn 5, finish Type III (imperial) or Type II (metric). ❑ Optional for Style 009N: Stainless steel oval neck track bolts meeting the requirements of ASTM F593, Group 2 (316 stainless steel), condition CW. Stainless steel Heavy Hex nuts meeting the requirements of ASTM F594, Group 2 (316 stainless steel), condition CW, with galling-resistant coating.' r Optional bolts/nuts are available in imperial size only. Coupling Linkage: High Strength Steel with comparable physical properties to that of the Track Bolt (ASTM A449). Linkage is zinc electroplated per ASTM B633 Fe/Zn 5, Type III Finish. • 10.64 7072 Rev 0 Updated 02/2021 ®2021 Victaulic Company.All rights reserved. victaulic.com 2 ✓cta ulr c` victaulic.com 4.0 DIMENSIONS Style 009N Two-Bolt Installation-Ready Coupling 11 I)11W ) ;l dL Ill�t Ar v �.0 ✓ Style 009N Pre-Assembled Style 009N Joint Assembled Size Bolt/Nut Dimensions Weight Actual Maximum Maximum Allow. Pre-assembled Joint Assembled Outside Working End Pipe End Approx. Nominal Diameter Pressure2 Load2 Separation Qty. Size X Y X Y Z (Each) inches inches I psi lb ' inches inches inches inches inches inches inches lb DN mm kPa N mm mm mm mm mm mm mm kg 1 Y4 1.660 365 790 0.10 '/a x 2 J'J 3.13 5.00 2.75 5.00 ' 2.00 : 1.4 DN32 42.4 2517 3514 2.54 M10x51 I 79 1 127 70 127 _ 51 0.6 • 1 Y2 1.900 365 1035 0.10 'A x 2 3.38 5.13 3.00 5.13 _. 2.00 1.5 DN40 48.3 2517 4604 I 2.54 2 M 10 x 51 86 130 76 130 51 0.7 2 2.375 365 i 1617 0.12 3a x 2 Y2 4.00 5.63 3.50 5.63 2.00 1.9 0N50 60.3 2517 I 7193 3.05 2 M10 x 63 102 143 89 143 1 51 0.9 21/2 2.875 365 I 2370 0.12 3a x 21Y2 4.50 6.13 4.00 6.13 2.00 2.1 73.0 2517 10542 3.05 2 M 10 x 63 114 156 102 156 51 1.0 3.000 365 2580 0.12 2/e x 2 Y2 4.63 6.00 4.13 6.13 2.00 2.1 DN65 76.1 2517 11476 3.05 2 M 10 x 63 118 152 105 156 51 1 1.0 3 3.500 365 3512 0.12 3/e x 2 Yz 5.13 6.75 4.63 6.75 2.00 2.3 DN80 4 88.9 2517 15622 3.05 2 M10 x 63 130 171 117 171 51 1.0 - 4 4.500 1 365 I 5805 0.17 3/e x 2 Y2 6.00 7.88 5.63 7.50 i 2.13 2.9 DN100 l 114 3 2517 I 25822 4.32 2 M10 x 63 152 200 143 191 I 54 1.3 4.250 365 5178 0.17 • 2/8 x 2 1/2 5.63 7.38 5.38 7.38 2.13 3.1 108.0 2517 23020 4.32 2 M10 x 63 152 1.87 137 187 54 1.4 - 5 5.563 365 8872 0.17 2 '/2 x 3 7.25 9.25 6.75 9.13 2.25 5.0 141.3 2517 39456 4.32 M12 x 76 184 235 171 232 57 2.3 5.250 365 7901 0.17 2 1/2x 3 6.63 9.00 6.38 9.00 2.25 4.8 133.0 2517 35106 4.32 M12 x 76 168 229 162 229 57 2.2 5.500 365 8672 0.17 1/2 x 3 6.88 9.25 6.75 9.13 2.25 4.9 DN125 139.7 2517 38529 4.32 2 M12x76 • 175 235 171 232 57 2.2 6 6.625 365 12582 0.17 /2 x 3/4 8.38 10.38 7.88 10.13 2.25 6.0 DN150 168.3 2517 44469 4.32 ; 2 M12 x 83 _ 213 264 200 257 57 2.7 6.250 365 11198 : 0.17 ' x 3'/4 7.88 10.00 7.38 9.88 2.25 5.6 159.0 2517 49753 4.32 2 M12 x 83 200 254 187 251 57 2.5 6.500 365 12112 0.17 I 1 1/2 x 31/4 8.00 10.25 7.75 10.13 2.25 6.0 2 I 165.1 2517 53813 4.32 M12 x 83 203 260 197 257 57 2.7 8 8.625 365 21326 0.17 1 Vs x4 10.88 13.38 10.25 13.13 2.50 11.4 0N200 219.1 2517 94863 4.32 2 M 16 x 101 276 340 260 333 64 5.2 8.500 365 1 20712 0.17 21 '/e x 4 10.63 13.25 10.25 10.13 • 2.63 11.4 216.0 2517 I 55968 4.32 ! i M16 x 101 270 337 260 1 257 67 5.2 10 10.750 300 27229 0.25 1 2/e x 6'/2 13.75 17.00 13.25 17.13 2.75 22.6 , DN250 273.0 2068 121121 6.4 2 M22 x 165 349 432 337 435 70 10.3 '.. 12 ' 12.750 ' 300 38303 ' 0.25 2/k x 6'/2 16.00 19.00 15.50 19.13 I 2.75 27.6 0N300 323.9 2068 1 170380 I 6.4 2 M22 x 165 406 l 483 394 486 I 70 12.5 2 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.See the Listings/Approvals section of this publication for ratings on other pipe. • 3 The allowable pipe separation dimension shown is for system layout purposes only.Style 009N couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. NOTES • When assembling Style 009N or Style 109 couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop. For Style 009N or Style 109 couplings,use FireLock No.006 end caps containing the"EZ"marking on the inside face or No.60 end caps containing the"QV EZ"marking on the inside face.Non-Victaulic end cap products shall not be used with Style 009N or Style 109 couplings.IMPORTANT!Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N or Style 109 coupling.There is no interchanging of gaskets or housings between coupling styles. • Use Of FlushSeal Gaskets For Dry Pipe Systems Style 009N or Style 109 couplings are supplied with Grade"E"Type A gaskets.These gaskets include an integral pipe stop,that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems.It should be noted that standard Victaulic FlushSeal gaskets cannot be used with the Style 009N or Style 109 couplings. • The Allowable Pipe End Separation dimension shown is for system layout purposes only.Style 009N or Style 109 Installation-Ready rigid couplings are considered rigid connections and will not accommodate expansion/contraction or angular movement of the piping system.Contact Victaulic for torsional resistance information. 10.64 7072 Rev 0 Updated 02/2021 0 2021 Victaulic Company.All rights reserved. victaulic.com 3 Jcta u I.c` IPS CARBON STEEL PIPE-GROOVED COUPLINGS 06.05 , VIC1A6116° IS AN ISO 9001 CL-H I. I'= r'',1 Style 75 Coupling (Flexible Coupling) PRODUCT DESCRIPTION Style 75 is available where moderate pressures are expected or weight considerations are a factor. Up to • 50% lighter in weightthan the Style 77,the Style 75 coupling is recommended for service up to 500 psi/ 4, 3450 kPa depending on size. Housings are cast in two identical pieces in all sizes. Hot-dip galvanized and special coatings are available for all sizes. i ®® See Victaulic publication 10.01 for details. Exaggerated for clarity DIMENSIONS Max.Imo- Deflect.Fr. Dimensions Aprx.-�I Max. Allow. Z Max CIA. Inches/millimeters Work End Pipe ® Wgt. rGr rile trial Nominal Actual Pres. Load End t Per Pipe Boll/Nut Each I I I I �I'I�, Size Out.Dia. PSI' Lbs.` Sep. Cplg. In./Ft. InJmm kPa N !minim Deg. minimNo.-Size Lbs. 1 F� InJmm Inches X Y Z kg MT 1 1.315 500 680 0-0.06 2` -43' 0.57 48 2-'/r,X 2 236 4.27 1.77 1.3 25 33.4 3450 3025 0-1.6 61 108 45 0.6 1 V. 1.660 500 1080 0-0.06 0.45 2.68 4.61 1.77 1.4 32 42.2 3450 4805 0-1.6 2 -1 D 38 2-1/¢X 2 68 Ill 45 0.6 172 1.900 500 1.420 0-0.06 1°-56' 0.40 2-3/a k 2 2.91 4.82 1.77 1.5 40 48.3 3450 6320 0-1.6 33 74 122 45 0,6 2 2.375 500 2.215 0-0.06 0.32 3.43 5.22 1.88 1.7 50 60.3 3450 9860 0-1.6 1 -31 26 2- /8 X 2 87 133 48 0.8 21/, 2.875 500 3.245 0-0.06 0.26 3.88 5.68 1.88 1.9 65 73,0 3450 14440 0.1.6 1°- 1 5' 22 2- /e X 2 98 144 48 0.9 76.1 mm # 3.000 500 3.535 0-0.06 1°- 12' 0.26 2 3/x H 2 4.00 5.90 1,88 1,9 76.1 3450 15730 0-1.6 22 102 150 48 0.9 3 3.500 500 4.800 0-0.06 1° 2, 0.22 2 '/2 X 23/q 4.50 7.00 1.88 2.9 80 88,9 3450 21360 0-1.6 18 114 178 48 1.3 3r/2 4.000 500 6.300 0-0.06 0.19 5.00 7.50 1.88 2.9 90 101.6 3450 28035 0-1.6 0°-54' 16 2-Vz X 2'4 127 191 48 1.3 4 4.500 500 7.950 0-0.13 1,-36, 0.34 2 ,/2 X 2'/< 5.80 8.03 2.13 4.1 100 114.3 3450 35380 0-3.2 28 141 204 54 1.9 108,0 m m 4.250 450 6.380 0-0.13 1°-41' 0.35 2-12 X 70.0 5.55 7.79 2.13 3.7 108.0 3100 28395 0-3.2 29 141 198 54 1.7 4V2 5.000 450 8.820 0-0.1 3 0.25 6.13 9.43 2.13 5.5 120 127.0 3100 39250 0-3.2 1°-26' 21 2-s/e X 3 Va 156 240 54 2.5 5 5.563 450 10.935 0-0.1 3 1° 18' 0.27 2.5/n X 3'/e 6.88 10.07 2.13 5.8 125 141.3 3100 48660 0-3.2 23 175 256 54 2.6 133.0 mm 5.250 450 9.735 0-0.13 1, -21, 0.28 2 16X825 6.55 9.37 2.13 6.0 133.0 3100 43325 0-3.2 24 166 238 54 2.7 139.7 mm # 539.7 3100 00 450 10�476605 06 0-• �3 1"- 18' 0.28 2-l/8 X 31h 6.80 9.173 459 24 543 6.3 152.4 m m 6.000 450 12.735 0-0.13 1,_ 12' 0.21 2-s/a g 3'/< 7.38 10.48 1.88 6.2 152.4 3100 56670 0-3.2 18 187 266 48 2.8 6 6.625 450 15.525 0-0.1 3 1°_5, 0.23 2 '/e X 3'4 8.00 11.07 2.13 7.0 150 168.3 3100 69085 0-3.2 18 203 281 54 3.2 • Table continued on page 2. 'I 4r t Refer-to notes on page 2. • • ®REGISTERED TRADEMARK OF VICTAULIC-0 COPYRIGHT 2005 VICTAULIC-PRINTED IN U.S.A.-SKU RWCAS-6A4MBY 1470 REV G United States• Phone:1-800-PICK-VIC(1-800-742-5842) • Fax:610-250-8817 •e-mail:pickvic@viclaulic com Canada• Phone:905-884-7444• Fax:905-884-9774 •e-mail:viccanada@victaulic.com Europe • Phone:32-9-381-1500• Fax:32-9-380-4438•e-mail:viceuro@viclaulic.be UK • Phone:44(0)14 38 7 41100• Fax:44(0)1438313883 • e-mail:viceure@victaulic.be ��� �® Central and South America • Phone:610-559-3300• Fax:610-559-3608•e-mail:uicel@viclaulic.com Australasia • Phone:86-21-54253300• Fax:86-21-54253671 • e-mail:vicapeeictaulic.com ,. 06.b5 DIMENSIONS .- Y �Z1 Pipe Size Deflect Fr. SP Dimensions Aprx. Max, Max, Allow. Cc t Inches/millimeters Work End Pipe Bolt/Nut WO. lit mil 9 Nominal i Actual Pres. Load End f Per Pipe No.-Size Each 1 I I I 1�t'L> Diameter : Out.Dia. PSI Lbs.' Sep. Cplg. In/Ft. Inches Lbs. tit In./mm InJmm kPa N InJmm Deg. mmlm mm X Y Z kg �� 1�' 159,0 mm 6.250 450 13.800 0- 3.2 1• -9' 0.24 2- 16 X 82.5 7.63 10.49 2.13 6.8 159.0 3100 61405 0-3,2 20 194 266 54 3.1 165.1 mm t 6271 16500 450 5.1 3t 00 14.940 6 00 0.- z3 1° _6' 0.23 2 -s/x X 3'I^ 7.84 10.66 2.06 2 3.3 203.2 in m# 8.000 450 22,635 0-0.13 0°-54' 0.16 2-'/q X 4'h 9.72 13.33 2.31 12.6 203,2 3100 100725 0-3,2 13 247 339 58 5.7 8 8.625 450 26.280 0-0.13 0°- 50' 0.18 2.3/n X 4'/n 10.34 13.97 2.32 12.4 200 219.1 3100 116945 0-3.2 14 263 355 59 5,6 254.0 m m# 10.000 350 27.500 0-0.13 0' 43' 0.15 2-'/e X 5'/z 12.16 15.81 2.53 20.R 254.0 2400 122375 0-3.2 11 309 402 64 9.4 304.8 m m# 12.000 350 39.500 0-0.13 0°- 36' 0.13 2-'/e X 5Vz 14.16 17,69 2.53 23.5 304.8 2400 175775 0-3.2 9 360 449 64 10.7 d Style 74 Couplings 'I c t Refer to notes below. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: Orange enamel • Optional: Hot dipped galvanized and others. Gasket: (specify choice')t • Grade"E"EPDM EPDM (Green color code). Temperature range -30°F to +230°F/-34°C to +110°C. Recommended for hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. U L classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot 18O'F/+82°C potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade"T"nitrile Nitrile (Orange color code). Temperature range -20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range; except hot, dry air over +140°F/+60°C and water over +150°F/+66°C. NOT RECOMMENDED FOR HOT WATER SERVICES. `Services listed are General Service Recommendations only.It should be noted thatthere are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended, tSupplemental lubricant is recommended for services installed at or continuously operating below 0°F/-18°C. Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. NOTES `Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 11/4times the figures shown. f Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each jointfor standard roll grooved pipe. Figures for standard cut grooved pipe may he doubled.These figures are maximums;for design and installation purposes these figures should he reduced by:50%for s/e- 3V2720-90 mm;25%far 47100 mm and larger. e Number of bolts required equals number of housing segments. t Style 75 couplings in these sizes have assembly lugs that aid in the proper assembly of the coupling. Metric thread size bolts are available (color coded gold)for all coupling sizes upon request Contact Victaulic for,details. WARNING: Depressurize and drain the piping system before attempting to install,remove,or adjust any Victaulic piping products. This product shall be manufactured by Victaulic or to Victaulic specifications,All products shall be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. 2 Style 75 Coupling CARBON STEEL PIPE-GROOVED FITTINGS 07.01 Grooved End Fittings 0 ® ® ids) LPCB SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Victaulic offers a broad line of fittings in sizes through 6071500mm in a variety of straight and » -- ^+'" " reducing styles. Most standard fittings are cast of durable ductile iron to precise tolerances. Victaulic standard fittings pressure ratings conform to the ratings of Victaulic Style 77 couplings. All fittings are supplied with grooves to permit fast installation without field preparation.The grooved design permits flexibility for easy alignment. These fittings are not intended for use with Victaulic couplings for plain end pipe(refer to Section 14.04 for fittings available for plain end applications). Fittings are provided in various materials including ductile iron,steel or segmentally welded steel NO.20 TEE depending on styles and size. Fittings are painted orange enamel with a galvanized finish available • • as an option,contact Victaulic for details. • Victaulic fittings are designed specifically for use in grooved piping systems.Fittings are provided t %,t: grooved conforming to standard steel pipe outside diameters.When connecting wafer or lug-type butterfly valves directly to Victaulic fittings with 741 or 743 Vic-Flangee adapters,check disc clearance dimensions with I.D.dimension of fitting. • Note:The following Victaulic fittings are VdS approved:No.10 90"Elbow,No.11 45"Elbow,No.20 Tee and No.60 Cap. Note:The following Victaulic fittings are LPCB approved:No.10 90"Elbow,No.11 45"Elbow,No.12 NO.10 ELBOW 22Vz"Elbow, No.13111<"Elbow, No.30 45"Lateral,No.30-R Reducing Lateral,No.100 Long Radius Elbow,No.110 Long Radius Elbow,No.20 Tee,No.35 Cross,No.60 Cap,No.25 Reducing Tee,No.33 True Wye,No.50 Concentric Reducer,No.51 Eccentric Reducer and No.29M Tee with Threaded Branch. Advanced Groove System—For 14—60"/350—1500mm piping systems,Victaulic now offers the Advanced Groove System(AGS).Refer to Section 20.05 for AGS fitting details. Stainless Steel—Grooved end fittings are available in Schedule 10 Type 316 stainless steel(Schedule 5,40 and Type 304 available as an option)in various sizes.Fitting center-to-end dimensions will vary depending upon type and schedule.Refer to Section 17.04 and 17.16 for details. Aluminum—Grooved end fittings are available in aluminum alloy 356 T6,in sizes from 1—8'Y25—200mm.Refer to Section 21.03 or contact Victaulic for details. Fabricated Steel—A full range of fabricated segemtnally welded steel or full flow grooved end fittings are available refer to section 07.04. Fabricated Steel with AGS Vic-Rings—A full range of full flow fabricated fittings with Vic-Rings are also available. AGS-ADVANCED GROOVE SYSTEM ALTERNATE STYLES Extra Heavy EndSeale"ES"Fittings—EndSeal fittings are available in 2—12"/50—300mm for use with"ES"grooved pipe and HP-70ES EndSeal couplings."ES"fittings are painted black for easy identification.EndSeal(and standard)fittings may be easily internally coated(by others)for severe service requirements.Always specify"ES EndSeal fittings"when ordering.See Section 07.03 for information on EndSeal fittings. Fittings Machined for Rubber or Urethane Lining(MRL)—For severe abrasive services,Victaulic fittings may be rubber or urethane lined(by others).Lining may be inside diameter/end(abrasion resistance)or wrap-around(corrosion and/or abrasion)machined.Refer to Section 25.03 or contact Victaulic for specific details. Note: Fittings are available with a variety of coatings upon request such as hot dip galvanized,epoxy, glass lined and others. • JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved• -— Date www.victaulic.com ✓Ctaulid VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV-R 07.01_1 • r CARBON STEEL PIPE-GROOVED FITTINGS 07.01 Grooved End Fittings DIMENSIONS Elbows NO. 10 90"Elbow NO. 11 45"Elbow trik,_,_ NO. 12 229"Elbow Etc E NO. 13 111/4"Elbow !° c to E --1 NO. 100 90"Long Radius mom= NO. 110 45"Long Radius t~C to El NO.12 GSNK c 10 EIII C tO E� �1___ ==#111 'o Cto CtoE to E j NO.10 NO.11 NO.12 NO.13 NO.100 NO.110 No.10 No.11 No.12 No.13 No.100t No.110t Size 90"Elbow 45"Elbow 22'/r`Elbow 11'A°Elbow 90'Long Radius Elbow CS) 45"Long Radius Elbow CS) Nominal Actual Approx. Approx. Approx. Approx. Approx. Approx. ` Size Outside Oia. C to E Wgt.Each C to E Wgt.Each C to E Wgt.Each C to E Wgt.Each C to E Wgt.Each C to E Wgt.Each Inches Inches Inches Lbs, Inches Lbs. Inches Lbs. Inches Lbs. Inches Lbs. Inches Lbs. mm ram mm kg mm kg ram kg nun kg ram kg rant kg sy I 1050 223 0.5 1.50 0.5 1.63sw I r 138sw .I 2.50sw 04 181sw I 03 70 26.9 57 0.2 38 l 0.2 41 I 35 64 0.2 I 46 I 0.1 1 1.315 2.25 0.6 1.75 0.6 3,25 06 138sw 03 1 2.88sw 06 2.25 sw I 0.5 25 337 57 0.3 44 0.3 83 03 35 01 I 73 0.3 57 0.2 h 1 1.660 2.75 1.0 175 0.9 175 11 OS 1.38sw 05 , 3.25sw '.1 2.38 sw 07 32 424 70 0.5 44 04 44 04 35. 02 83 0.5 60 03 --Pr 1%v 1,900 I 275 1 2 175 0.9 1.75 08 1 38sw C 5 3.636w 2.2 ll 2.50sw 1.3 40 48.3 70 0.5 44 i 0.4 44 04 35 0.2 92 1.0 64. 0.6 2 2.375 325 1.8 2.00 1.3 375@ 1.4 1.38 10 438 2.5 1 2.75 18 50 603 83 0.8 51 06 1 95 0.6 35 05 11 11 70 0.8 214 2875 375 3.2 2.25 2.2 400@ 2.3 150 11 5.13 3.4 3.00 2.8 65 730 95 1.5 57 10 102 1.0 38 05 130 1.5 I 76 1.3 3.000 375 37 2.25 34 224 150 761 ram 761 95 17 57 15 57 ' 38 I 3 3.500 1 4.25 45 250 31 450@ 31 1.50 21 1 588 60 3.38 49 80 88.9 I 108 2.0 64 14 I 114 1 4 38 1 0 149 2.7 86 2.2 31/2 4.000 4.50 5.6 2.75 ] 4.3 . 2.50 sw 4.0 175sva 27 _ _ 90 101.6 j 114 25 70 2 0 64 1 8 44 1 2 4 4.500 5.00 71 300 56 2.88 5.6 175 36 7.50 123 400 73 100 114.3 127 I 3.2 /6 2 5 73 2.5 44 1 6 191 • 5.6 102 3.3 4.250 5.00 11.0 3.00 5.6 108.0mm 1080 127 5.0 76 4 2.5 j 4'S 5.000 5.25 sw 10.0 3.13 sw 65 3 50sw 6.6 1 88sw 4.2 120 1270 133 45 79 27 89 30 48 1.9 5 5563 550 117 3.25 83 288sw 78 200sw 5.0 9.25sw 18.2 4.88 s5> 14.8 125 141.3 140 5.3 83 3.8 73 35 51 2.2 235 8.3 124 6.7 1330 ram 5.250 5.50 11 7 3.25 8.3 __ 133.0 140 5.3 83 3.8_ 1397 rant 5.500 5.50 11 7 3.25 8.3 2.87 I 2.00 '.. 1397 140 _53. 83 . 3.8 73 ,.. 51 - I - 6 6625 6.50 li 17.2 3.50 108 625@ 122 2.00 70 1075 304 I 5.50 174 150 168 3 165 78 89 49 159 5.5 51 3.2 273 13.8 140 7.9 159.0 mm 6.250 6.50 18.6 3.50 108 1 - - - - - - - - 1590 165 84 89 49 165.1 ram 6.500 5 650 15.5 3.50 98 1 313 114 200 74 10.75sw 290 50sw 190 1651 165 70 1 89 44 79 52 51 34 273 13.2 I 140 8.6 @ Gooseneck design.end-to-end dimension fittings in this size.contact your nearest Victaulic sales office t Chinese standard sizes Note:All fittings are ductile iron unless otherwise noted with an"sw"or"s" 5=Carbon Steel Direct Roll Groove (OGS) SW=Carbon Steel Segmentally Welded www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. a lCta ll l I C 07.01..4 r victaulic.com I Fittings I Grooved End I Publication 07.01 ' , Concentric/Eccentric Reducer E No. 50 Concentric I`to E'� EtoE No. 51 Eccentric � � '`-E� r-FLi�ILI E 11� [Ell I~toil r- etoe 1 l.-EtoE ,.._EtoI"''IIInd UL_- 1E20 No.50 No.51 Fabricated Steel Fabricated Steel No. 50 No. 51 No.50 Concentric Fabricated Steel Fabricated Steel Size _ Reducer No.51 Eccentric Reducer No..50 No.51 No.50 No. 51 Approx. Approx. Nominal Size E to E Weight Each E to E Weight Each No.50 Concentric inches inches lbs. inches lbs. Size Reducer No.51 Eccentric Reducer mm mm kg mm kg Approx. Approx. 11/4 4.6 Nominal Size E to E Weight Each E to E Weight Each 32 + 2.1 inches inches lbs. inches lbs. 11/2 3.00(sw) 2.6 10.00(sw) 8.1 ___ mm mm kg mm kg 40 76 1.2 254 3.7 _ 11/4 % 1.9 2 3.00 2.4 4.00 3.3 32 x 20 + 0.9 50 76 1.1 102 1.5 1 1.9 21/2 3.00 2.7 4.00 3.4 25 + 0.9 65 76 1.2 102 1.5 1 Y2 34 1.4 3 3.00 3.2 4.00 3.5 40 x 20 + 0.6 80 76 1.4 102 1.6 1 2.50 0.8 8.50(sw) 4.5 31h 3.00 2.9 10.00(sw) 8.0 25 64 0.4 216 2.0 90 76 1.3 254 3.6 ► 11/4 2.50 1.0 5 2 11.00(sw) 9.0 11.00(Sw) 5.2 32 64 0.5 125 x 50 279 4.1 279 2.4 2 34 2.50 0.9 9.00(sw) 2.0 2'h 4.00 4.3 11.00(sw) 10.8 50 x 20 64 0.3 229 0.9 65 102 2.0 279 4.9 1 2.50 0.7 9.00(sw) 2.3 3 4.00 5.5 11.00(sw) 11.1 25 64 0.3 229 1.0 80 102 2.5 279 5.0 1'% 2.50 1.2 9.00(5W) 4.6 4 3.50 4.3 5.00 12.0 32 64 0.5 229 2.1 100 89 1.9 127 5.4 1'h 3.50 1.0 3.50 1.1 6 1 4.00 5.0 11.50(sw) 14.5 x 40 89 0.5 89 0.5 150 25 102 2.3 292 6.6 2' 12 3/4 1.3 3.3 1'/z 5.5 65 X 20 + 0.6 + 1.5 40 + 2.5 + + 1 2.50 1.1 9.50 3.5 2-- -4.00 6.6 11.50(sw) 14.5 25 64 0.5 241 1.6 50 102 3.0 292 6.6 11/4 3.50 3.3 3.50 1.4 21/2 4.00 6.4 11.50(sw) 14.2 32 89 1.5 89 0.6 65 102 2.9 292 6.4 11/2 2.50 3.6 9.50(sw) 3.7 3 4.00 6.4 5.50 15.0 40 64 1.6 241 1.7 80 102 2.9 140 6.8 2 2.50 3.9 3.50 4.3 4 4.00 6.5 5.50 17.0 50 64 1.8 89 2.0 100 102 2.9 140 7.7 3 3/4 1.5 4.5 5 4.00 6.4 5.50 17.0 80 x 20 + 0.7 + 2.0 125 102 2.9 140 7.7 1 2.50 1.3 9.50(sw) 4.8 8 21h 16.00 7.9 12.00(sw) 26.1 25 64 0.6 241 2.2 200 x 65 406 3.6 305 11.8 13/4 2.50 1.4 4.8 3 5.00 9.3 12.00(sw) 22.0 32 64 0.6 + 2.2 80 127 4.2 305 10.0 11/2 2.50 -_-_-5.1 9.50(sw)�_-5.1 4 5.00 10.4 12.00(sw) 23.0 40 64 2.3 241 2.3 100 127 4.8 305 10.4 2 2.50 1.6 3.50 6.0 5 5.00 11.6 12.00(sw) 23.0 50 64 0.7 89 2.7 125 127 5.2 305 10.4 21/2 2.50 1.8 3.50 7.0 6 5.00 11.9 6.00 24.0 65 64 0.8 89 3.2 150 127 5.4 152 10.9 2.50 2.1 15 For 14'7350 mm and larger roll grooved systems,Victaulic offers the 76.1 64 1.0 Advanced Groove System(AGS).For pricing and availability of cut groove 31/2 3 2.50 2.0 9.50(sw) 7.0 fittings in this size,contact your nearest Victaulic sales representative. 90 x 80 64 0.9 241 3.2 4 1 3.00 3.0 13.00(SW) 6.5 100 x 25 76 1.4 330 2.9 15 For 14'/350 mm and larger roll grooved systems,Victaulic offers the Advanced Groove System(AGS).For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. 07.01 1449 Rev X Updated 10/2014 tt 2014 Victaulic Company.All rights reserved. victaulic.com 21 ictaulic° . Vie®-End II End of Run Fitting ✓ctauLc` No. 67 10.21 1.0 PRODUCT DESCRIPTION Available Sizes • 1 —3'/DN32— DN80 with '/DN15, 3/4"/DN20 or 1'/DN25 female threaded NPT or BSPT outlet. Pipe Material • Carbon Steel, Schedule 10, Schedule 40. For use with alternative materials and wall thicknesses please contact Victaulic. Maximum Working Pressure • Up to 365 psi/2500 kPa. Function • End of branchline elbow fitting for sprinkler connection. 2.0 CERTIFICATION/LISTINGS l•RD 3.0 SPECIFICATIONS — MATERIAL Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12, painted Orange Enamel. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. ❑ Optional: Hot dipped galvanized. Outlet: NPT ❑ Optional: BSPT ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. • • System No. Location Spec Section Paragraph Submitted By Date Approved Date • victaulic.com 10.21 3209 Rev F Updated 03/2017 ®2017 Victaulic Company.All rights reserved. 1 .ctaulrc` victaulic.com 4.0 DIMENSIONS No.67 C to TE C to GE Approximate Nominal Weight Size C to GE C to TE (Each) inches inches inches lb DN mm mm kg 1 3/4 x th 1.875 1.38 0.6 DN32 DN15 48 35 0.3 14 1.875 1.38 0.5 DN20 ! 48 35 0.2 1,. 1 2 1.75 0.6 DN25 51 44 0.3 1'h x '/ 1.875 1.5 0.7 DN40 DN15 48 38 0.3 414 1.875 1.5 0.7 DN20 48 38 0.3 1 2 1.625 0.7 DN25 51 41 0.3 2 x 'h 1.875 1.75 0.7 DN50 DN15 48 44 0.3 / 1.875 1.75 0.7 DN20 48 44 0.3 1 2 1.75 0.9 DN25 51 44 0.4 21/2 x 'h 1.875 2 1.3 DN65 DN15 48 51 0.6 3/4 1.875 2 1.2 DN20 48 51 0.6 1 2 2 1.3 DN25 51 51 0.6 . i ....3 x 3 2 2.375 - 2.0 DN80 DN20 51 60 0.9 1 2 2.375 1.9 DN25 51 60 0.9 5.0 PERFORMANCE Please see applicable coupling publication for performance, or contact Victaulic for more information. 10.21 3209 Rev F Updated 03/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 2 ✓ctaulrc° victaulic.com • • • 6.0 NOTIFICATIONS A WARNING • This product must be installed by an experienced, trained installer, in accordance with the instructions provided with each valve. These instructions contain important information. • Failure to follow these instructions may result in serious personal injury, property damage, or valve leakage. If you need additional copies of this product literature or the valve installation instructions, or if you have any questions about the safe installation and use of this device, contact Victaulic Company, P.O. Box 31, Easton, PA 18044-0031 U SA, Telephone: 001-610-559-3300. 7.0 REFERENCE MATERIALS 10.64:FireLock EZ"^Style 009N Rigid Coupling • • • User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products for a particular end-use application,in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications,and the applicable building codes and related Victaulic reserves the right to change product specifications,designs and standard regulations as well as Victaulic performance,maintenance,safety,and warning equipment without notice and without incurring obligations. instructions.Nothing In this or any other document,nor any verbal recommendation, Installation advice,or opinion from any Victaulic employee,shall be deemed to alter,vary,supersede, Reference should always be made to the Victaulic installation handbook or installation or waive any provision of Victaulic Company's standard conditions of sale,installation instructions of the product you are instating.Handbooks are included with each shipment guide,or this disclaimer. of Victaulic products,providing complete installation and assembly data,and are available Intellectual Property Rights in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warranty product,service,or design is intended,or should be constructed,to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patentor other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design,or as a recommendation for the use of such Trademarks material,product,service,or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right.The terms"Patented"or"Patent Pending"refer to design or utility patents Victaulic Company,and/or its affiliated entities,in the U.S.and/or other countries. • or patent applications for articles and/or methods of use in the United States and/or other countries. 10.21 3209 Rev F Updated 03/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com ✓ctauluc" Victaulic° VicFlexTM Sprinkler Fittings • ictaulic° Series AH2 and AH2-CC Braided Flexible Hoses 10.85 TV IC Series AH2 Series AH2-CC 1.0 PRODUCT DESCRIPTION Available Sizes by Component -*• Series AH2 Braided Hose: 31, 36, 48, 60, 72'/790, 914, 1219, 1525, 1830mm. Note: length includes adapter nipple and 5.75/140mm straight reducer. • Series AH2-CC Braided Hose: 31, 36, 48, 60, 72/790, 914, 1219, 1525, 1830 mm. Note: length includes captured coupling and 5.75/140 mm straight reducer. • Sprinkler Reducers: • Sprinkler Connections: 1/z and 3/e/15 and 20mm • Straight Lengths: 5.75, 9, 13'/140, 230, 330 mm • 90"Elbows: • Short (typically used with concealed sprinklers) • Long (typically used with recessed pendent sprinklers) • Low Profile Short (for use with Style AB5, AB11 and AB12 Bracket) • Low Profile Long (for use with Style AB5, AB11 and AB12 Bracket) • Inlet Connections: • 1'/25 mm Grooved IGS • i'/25 mm NPT or BSPT adapter nipples for attaching to pipe and fittings outlined in NFPA standards. • 3/e/20 mm NPT or BSPT adapter nipples available for VdS. • 11/4"/32mm BSPT adapter nipples available for LPCB. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. •System No. Location Spec Section Paragraph Submitted By Date Approved Date • victaulic.com 10.85 5839 Rev AB Updated 08/2017 ©2017 Victaulic Company.All rights reserved. 1 .ctaul,c victaulic.com 1.0 PRODUCT DESCRIPTION (Continued) • Brackets: • Style AB1 for suspended and hard-lid ceilings, allows installation before most ceiling tiles in place • Style AB2 for suspended and hard-lid ceilings, allows for vertical sprinkler adjustment, and installation before most ceiling tiles in place • Style AB3 for surface mount applications, wood, metal and block walls, or ceilings • Style AB4 for hard-lid ceilings with hat furring channel grid systems, allows for vertical sprinkler adjustment • Style AB5 for hard-lid ceilings, allows for vertical sprinkler adjustment • Style AB7 for suspended and hard-lid ceilings • Style AB7 Adjustable for suspended and hard-lid ceilings • Style AB8 for hard-lid ceilings with CD 60/27 profile metal studs (regionally available) • Style AB9 for hard-lid ceilings with hat furring channel grid systems • Style AB10 for Armstrong®TechZoner" ceilings • Style AB11 for lay-in panel suspended t-grid ceilings or drywall suspended t-grid ceilings, allows for low profile installations (use only with 90° low profile elbows) • Style AB12 for suspended and hard-lid ceilings, allows for vertical sprinkler adjustment, and allows for low profile installation down to 411/100mm. Maximum Working Temperature • 225°F/107°C Maximum Working Pressure • 200 psi/1375 kPa (FM Approval) • 175 psi/1206 kPa (cULus Listed) • 1600 kPa/232 psi (VdS/LPCB Approved) • 1.4 MPa (CCCf Approved) Connections • To adapter nipple (inlet) via • 1725.4 mm Grooved IGS • 1"/25.4 mm NPT or BSPT male thread • 3/4"/20 mm BSPT male thread (VdS only) • 11/4"/32 mm BSPT male thread (LPCB only) • To sprinkler head (outlet) via th" or 3/4715 mm or 20 mm Minimum Bend Radius • 7"/178 mm (FM/CCCf Approval) • 2751 mm (cULus Listed) • 3'1/76.2 mm (VdS/LPCB Approved) Maximum Allowable Sprinkler K-Factors • FM (1/2"/15mm reducer) K5.6/8,1 (S.I.), (3/4"/20mm reducer) K14.0/20,2 (S.I.) • cULus (1/2"/15mm reducer) K8.0/11,5 (S.I.), (3/4"/20mm reducer) K14.0/20,2 (S.I.) • VdS/LPCB ('h"/15mm reducer) K5.6/8,1 (S.I.), (3/a"/20mm reducer) K8.0/11,5 (S.I.) 2.0 CERTIFICATION/LISTINGS ® e °1 OS VdS LPCB u 44 LISTED ,....N.... • 10.85 5839 Rev AB Updatec 08/2017 ©2017 Victautc Company.All rights reserved. victaulic.com 2 ✓ctaulic victaulic.com • 3.0 SPECIFICATIONS — MATERIAL Series AH2 • Flexible Hose: 300-series Stainless Steel • Collar/Weld Fitting: 300-series Stainless Steel • Gasket Seal: Victaulic EPDM • Isolation Ring: Nylon • Nut and Nipple: Carbon Steel, Zinc Plated • Reducer (1h"/15 mm or 3/4"/20mm):mm): Carbon Steel, Zinc-Plated • Low Profile Elbows: Stainless Steel Brackets: Carbon Steel, Zinc-Plated Series AH2-CC • Flexible Hose: 300-series Stainless Steel • Collar/Weld Fitting: 300-series Stainless Steel • Gasket Seal: Victaulic EPDM • Isolation Ring: Nylon • Coupling Retainer Ring: Polyethelene • Nut and Nipple: Carbon Steel, Zinc Plated • Reducer (1/2"/15 mm or 3/4720 mm): Carbon Steel, Zinc-Plated • Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Coupling Housing Coating: • Orange enamel (North America, Asia Pacific). • Red enamel (Europe). • Hot dipped galvanized. Gasket:' • Grade "E" EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic GasKet Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. • Bolts/Nut: Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A 449 and physical requirements of ASTM A 183. • Linkage: CrMo Alloy Steel zinc electroplated per ASTM B633 Zn/Fe 5, Type III Finish 10.85 5839 Rev AB Updated 08/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 3 ✓ctaul.c" victaulic.com 4.0 DIMENSIONS Product Details - Series AH2 Braided Hose Item Description 1 _ _ Flexible Hose 2 Isolation Ring l 5 1 (6) 8 ( i q) 3 Gasket ._ 4 Nut u____imuum — 5 Adapter Nipple mnnninnrn,n,u,,,,ni '_ 6 ___ Braid l 7 Collar/Weld Fitting A B 8 Sleeve Hose Length Dimensions Hose Length A B inches inches inches mm mm mm 31/790 25.3/641 31/790 '. 36/915 _--_--- 31.3/794 36/915 —fir 48/1219 42.3/1073 48/1220 60/1525 54.3/1378 60/1525 li 72/1830 66.3/1683 _T-_- 72/1830 Series AH2-CC Braided Hose Item Description 1 © © p ° 00 1 Flexible Hose 2 I Isolation Ring '� uu uu uu uuu r,,, --- ® �II�Ill' iu wflllf{R.W'I' 3 Gasket _ ` un ,i 4 Nut A 5 Captured Coupling B . __.___6 Braid 7 Collar/Weld Fitting_ -- - 8 Sleeve Hose Length A B inches inches inches mm mm mm 31/790 24.5/622 29.8/757 36/915 29.5/749 34.8/884 48/1219 41.5/1054 46.8/1189 60/1525 53.5/1359 58.8/1494 72/1830 65.5/1664 70.8/1798 • • 10.85 5839 Rev AB Updated 08/2017 ®2017 Victaulic Company.All rights reserved. victaulic.com 4 Ncircta u I iI c victaulic.com • 0 • 4.0 DIMENSIONS (Continued) Standard Reducer alu�I IIIIIIIII IIIIIIIIIIIIIIIIIIIIIII 5.75'/140 mm straight reducer Optional Reducers I tt t P` 9.0"/229 mm straight reducer 13.0'/330 mm straight reducer 2.62"/ --:, 66.5 mm �a-- .25 m III ♦ '62 mm �_ I I'l% 6.57"/ 166.9m 483'7 =_ m 122.7mm — N Short 90°elbow reducer Long 90°elbow reducer NOTE • The Short 90°elbow reducer is typically used with concealed sprinklers while the longer 90 elbow is typically used in the installation of recessed pendent sprinklers. • FM/VdS Approved only. Low Profile II,I' _ = 4.59"/ = — 116 mm ■E 2.84"/ - = 72 mm = _ 1 4'/ 1.4"/ 36mm 36mm Short 90°elbow reducer Long 90°elbow reducer NOTE • Style AB11:When low profiles elbows are used with the Style AB11 bracket,the Low Profile Short Elbow is typically used with concealed sprinklers while the Low Profile Long Elbow is typically used in the installation of recessed pendent sprinklers. • • • 10.85 5839 Rev AB Updated 08/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 5 �ctaul.c victaulic.com • 4.1 DIMENSIONS VicFlex Brackets Style AB1 • Suspended Ceilings �' • Hard-Lid Ceilings (FM Only) i/ Item 1 Description r 1 24"/610 mm or 48Y1219 mm Square Bar I `� 2 Patented Center Bracket 3 ,: End Bracket -. . � 110-- O NOTE • Both sizes FM/VdS/LPCB Approved,cULus listed 1 0 6 Style AB2 • Suspended Ceilings • Hard-Lid Ceilings Li: A Item Descriptionion 1 24"/610mmor48/1219mm Square Bar �2 Patented Vertically Adjustable Center Bracket 3 1 End Bracket NOTE ---- � Q • Both sizes FM/VdS/LPCB Approved,cULus listed B '` ili 04 Style AB3 `— • Surface Mount Applications I .au �_—zio. • FM/LPCB Approved lb f fi,... — 10.85 5839 Rev AB Updated 08/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 6 ✓ctaulrc' victaulic.com 4.2 DIMENSIONS VicFlex Brackets Style AB4 -` 0 • Hard-Lid Ceilings with Hat furring ` channel grid system 401 Item Desor48"/1219mm 2 1 24'/610mmor46"11219mmS uare Bar nted ly e Center NOT3 E Pate End Bracket)for Hat Furring Bracket ing Channel )11i • Both sizes FM/VdS/LPCB Approved,cULus listed. Style AB5 ,. O • Hard-Lid Ceilings ��,, Item Description z ' " 1vs fir, A 2 Patented Vertically Ad)ustable Center Bracket NOTE / i • Both sizes FM/VdS/LPCB Approved,cULus listed. Style AB7 • Suspended Ceilings • Hard-Lid Ceilings Item Description _- 1 24"/61ommor48'/1219mm Square Bar ----1� z 2 ' Patented 1-Beer Center Bracket 3 End Bracket 0 NOTE • Both sizes FM/VdS/LPCB Approved. lid e Style AB7 Adjustable • Suspended Ceilings 1s • Hard-Lid Ceilings Item Description 1 J 700 mm or 1400mm Square Bar 2 Patented 1-Bee2®Center Bracket 3 1 End Bracket(adjustable) NOTE • Both sizes FM/VdS/LPCB Approved. 1,74 10.85 5839 Rev AB Updated 08/2017 ®2017 Victaulic Company.All rights reserved. victaulic.com 7 ✓cta u L c victaulic.com • I • 4.3 DIMENSIONS VicFlex Brackets Style AB8 FAO • Hard-Lid Ceilings �� Item Description 1 � 700mm or 1400mm Square Bar I � 2 Patented Vertically Adjustable Center Bracket 3 End Bracket 401 NOTE • Both sizes FM/VdS/LPCB Approved. �\ Style AB10 • Suspended ceilings © .y • Armstrong®TechZone" f o ! '- Item Description 1 6/152mm Square Bar 2 l Patented 1-Bee2'Center Bracket 3 End Bracket NOTE • FM/VdS/LPCB Approved,cULus listed. Style AB11 • Suspended ceilings 1. s • Hard-Lid ceilings Item Description 1 24"/610mm or 4871219 mm Square Bar 2 Patented 1-Bee2`Center Bracket L_3 End Bracket NOTE • FM/VdS Approved,cULus 'A OP P Style AB12 • Suspended ceilings ') ` iE5)' • Hard-Lid ceilings ®® —�' n Item Description e+ • 1 Style AB12 Bracket Body 2 #2 Square Drive Set Screw 0 NOTE • FM Approved. 10.85 5839 Rev AB Updated 08/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 8 ✓ctaulic victaulic.com • 4.4 DIMENSIONS (Continued) CLEARANCES ABOVE CEILING Series AH2 Braided Hose and Style AB2 Bracket Hard-lid Ceiling with Concealed Sprinkler Hard-lid Ceiling with Recessed Sprinkler inii C eras Ir.' we `d_, 1 r,w . nlie hl 9 ne1A•r1 1 Jr � a• m- ! k}C 4I1 1J } -N i Si f a .. =m1 , 4 %Iiwi%% O/ A10. 1' It'.]::::: f�il! hor. M •J yiy n IIMdiI/ oiai.°ri ul[ a4�li V3802 1/2 712.7mm Max. Recess V2707/'/19mm Max. Recess Hose Clearance Chart Hose Clearance Chart Dimensioni i Dimension inches inches inchesinchesinches inches inches inches inches inches inches inches 1 mm mm mm mm mm mm mm mm mm mm mm mm Minimum 2 3 4 5 6 7 Minimum ''. 2 3 4 5 6 7 R Bend Radius 50 80 100 125 150 175 R Bend Radius 50 80 100 125 150 175 A Min. 7.6 8.6 9.6 10.6 11.6 12.6 A Min. 6.1 7.1 8.1 9.1 10.1 11.1 193 218 244 269 295 320 155 180 206 231 256 282 Hard-lid Ceiling Grid with Recessed Sprinkler with Hard-lid Ceiling with Concealed Sprinkler with 90° Elbow (Short) 90° Elbow (Long) EI:iI t15I:l�I , 4z i.. r:= J gut _ $ivbeBSrvmM 1I 9 FRi la n 5 1 P Ic 3-iu I / i. an 5k llJ I,Jos'¢C .°J<'F L.J tv. u - �r. ma G �is ;,,. 5� i '' aa�ir/. �IHi111Ii// asi� //I« 11 " V3802 1712.7mm Max. Recess V2707 3/4"/19mm Max. Recess Hose Clearance Chart Hose Clearance Chart _ Dimension Dimension inches inches mm mm nX a- `s r e.-sx g :i¢s n,; < ;,.v { t r `f 1. ++�`- ' `' NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AB Updated 08/2017 0 2017 Victaulic Company.All rights reserved. victaulic.com 10 ✓ctau6c victaulic.com ' 4.6 DIMENSIONS (Continued) CLEARANCES ABOVE CEILING Series AH2 Braided Hose and Style AB5 Bracket Hard-lid Ceiling with Recessed Sprinkler km, rim •rill r. me. A= I z,,, "mm r a'�•sy°I 4 ��� I IR k° fir•. (( I•si.J W153, e R Q< ,P Tv,.,,,,a sknl Npfic^ n V2707/"/19mm Max. Recess V3802 W/13mm Max. Recess Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches inches inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm mm mm R Minimum 2 3 4 5 6 7 R Minimum 2 3 4 5 6 7 Bend Radius 50 80 100 125 150 175 Bend Radius 50 80 100 125 150 175 A Min 6" 7.1 81 91 10.1 11.1 A Min. 7.6 8.6 9.6 106 11.6 12.61 t 155 I.180 206 231 256 i 282 i I 193 1218 , 244 269 1 295 I 320 Recessed Pendent with 90° Elbow (Long) Hard-lid Ceiling with Concealed Pendent with 90° Elbow (Short) i II Ceav a.e rp, ���/ ,- /� • /v/J � A ^ u. kW JC . • ,.mn .c. V2707 3/4"/19mm Max. Recess V3802'h"113mm Max. Recess Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches inches mm mm 3.3 A f Min. 91 A .Min. 84 NOTE • Variations of ceiling grids,sprinkler heads, brackets,and hoses are permitted but may result in clearance differences from the figures above. • 10.85 5839 Rev AB Updated 08/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 13 ✓ctauliC' victaulic.com 4.6 DIMENSIONS (Continued) ' CLEARANCES ABOVE CEILING Series AH2 Braided Hose and Style AB11 Bracket (LOW PROFILE SOLUTION) Suspended Ceiling Grid with Recessed Sprinkler with LP 90° Elbow (Long) Bracket assembl 1. it Style ABll dI !iI A 1M1 1M1 2'/e"/60mm See chart r�r —,= r_r max.hole 1 ' 76 mm, , min.hole , i 44, H o os/e"/l6mm�,_ - Typical I !i'lIi1.7'743 mm 1 . — ceiling the I I 'd �' 'Typical ceiling grid ®�/, 41 ll alIiIng — J Wil\_Finished ISee Note • ceiling face 24"/610 mm - or48171219mm on Center V2707 3/4"/19 mm MAX.RECESS V2707 MAX.EXTENSION Hose Clearance Chart Dimension inches ', mm A Min: 4.0 100 Suspended Ceiling Grid with Concealed Pendent with LP 90° Elbow (Short) • Bracket assembly/I !ill Style A811 A ,1�1, 1_r1_! ,1�1, 2"/2.768 mm liN See chart rci — i i -is—max.holey la 1 - ;—_) . 763mm 23/e760 mm I I I min.hole I 1 I -�� I I 5 'i�l I''r r /Typical mil II 1.7'Y43 mm r 1".. I I =��i_)' ceiling tile I I j1 ..r Typical ceiling gild " i• III Iir r Finished See Note 24/610 mm Ceiling Face or48'/1210 mm on Center V3802' /13 mm MAX.RECESS V3802 MAX.EXTENSION Hose Clearance Chart Dimension inches mm A Min. 3:9 99 NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. . 10.85 5839 Rev AB Updated 08/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 14 ./ taulrc victaulic.com ' 4.6 DIMENSIONS (Continued) CLEARANCES ABOVE CEILING Series AH2 Braided Hose and Style AB12 Bracket Suspended Ceiling Grid with Recessed Sprinkler Suspended Ceiling Grid with Recessed Sprinkler and with Low Profile Short Elbow Straight 5.75"/140mm Reducer I Unfinished".. Ceiling Face,, IKinch/ 9mm / 'hinMM10 R,eaded Rut (31ooV09-meter Maximum Length) iill. . I mm I I W; r A. pUnfinlsl d = See Fable 1Ye inch/ Ceiling Face I = 1n1'- t erg)'Vh110 2tol9 mm .;imch 1 M- Threaded Rod A � �,. Maximum L JIF;�, SeeTahlle � _I r• 3 7'I See cable �p - _-_-� 13-edV09- t 11111 III l•lull- R E' ■ p� R'Seel-able L Firlsned Facet �, �F �egEinmt ,e.ieb,lmm typical Cerny -yplral Cull V1707 M"I11.J mm MAX.RECESS V2707%"/19 mm MAX.RECESS Low Profile Low Profile Standard Standard Standard Dimension Short Elbow Long Elbow Short Elbow Long Elbow Straight Reducer 3/4719mm I. 3/4'/19mm W/l9mm 3/a"/19mm Ye/19mm Recessed*Concealed Recessed Concealed Recessed Concealed Recessed Concealed Recessed Concealed inches inches inches inches inches inches inches ' inches inches inches mm 1 mm mm mm mm mm mm mm mm mm A Minimum Required I 4.0 5.5 I 5.6 7.2 5.9 7.5 '1 7.7 9.3 15.0 16.6 I, Installation Space 101.6 1 139.7 142.2 182.9 149.9 190.5 I 195.6 236.2 I 381.0 421.6 I Distance from Top of 0.5 2.0 1.5 1.5 1.5 1.5 3.0 3.0 3.0 3.0 B Typical Ceiling Tile to 12.7 50.8 38.1 38.1 38.1 38.1 76.2 76.2 76.2 76.2 Bottom of Gate 'Adjustability will be limited NOTE • Sprinkler location relative to'/e"threaded rod is 1 Ye"/29mm center-to-center. • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. • 10.85 5839 Rev AB Updated 08/2017 ®2017 Victaulic Company.All rights reserved. victaulic.com 15 ✓ctaul6c victaulic.com 4.6 DIMENSIONS (Continued) ' . CLEARANCES ABOVE CEILING Series AH2 Braided Hose and Style AB3 Bracket Surface Mount Application with Recessed Sprinkler Cc ME i UM 33/4"/ e 95.3mm rrA- Ell See Note z,7 lir E -3- r I LA A111111/ tr.r.mir A iL i. r$1.— 23/8'760 mm max.hole 2"/51 mm min hole Hose Clearances Wall Thickness 2 4 6 8 10 2 4 6 8 10 50 100 150 200 250 50 100 150 200 250 Outlet Length 5.75 9 13 5.75 9 ' 13 9 13 13 13 5.75 1 9 13 5.75 , 9 13 9 13 13 13 Hose 11.6 14.8 18.8 9 6 12 8 16.8 10.8 14.8 12.8 10.8 12.6` 15.8 19.8 10.6 ' 13.8 17 8 : 11.8 15.8 33.8 330.211.8 B" 11461 2286 3302 1461 2286 330.2 2286 3302 3302 3302 146.1 228., 9.2 146.1,228.1 3302 228.6 3302 13 Clearance'C' 294 376 478 243 1 325 427 275 376 325 275 319 402 503 268 351 452 300 402 351 300 Bend Radius 7 8 "R" 175 200 NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. • See installation instructions for mounting screw type and size. • 10.85 5839 Rev AB Updated 08/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 16 Jctaul.c' victaulic.com ' 4.7 DIMENSIONS BRANCHLINE CLEARANCES Series AH2 Braided Hose with female threaded outlet Series AH2-CC Braided Hose with grooved outlet R See chart R See chart •��� A See cha rt A EMS See chart J: 1� Female Threaded Weld Outlet No.142 Grooved Weld Outlet \IllioJ 2"/50 mm J 2750 mm Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches inches inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm mm mm Minimum 2 3 4 5 6 7 R Minimum 2 3 4 5 6 7 Bend Radius 50 80 100 125 150 175 Bend Radius 50 80 100 125 150 175 A Min. 8.4 9.4 10.4 11.4 12 4 13.41 A Min. ' 7.1 8.1 91 10.1 11.1 12.1 214 I l 264 1290 i 315 1341 180 i 205 l 231 256 l 281 [ 307 • 10.85 5839 Rev AB Updated 08/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 17 ✓cta u L c victaulic.com f • 4.7 DIMENSIONS (Continued) BRANCHLINE CLEARANCES Series AH2 Braided Hose with Style 922 threaded outlet Series AH2-CC Braided Hose with Style 922 grooved outlet R See chart MIIIIMINIIIIIII IIME See chart �i��i� A .OM See chaff U ■■ See chart Style 922Threaded 71 I rod .. • Mechanical Tee a P.,./�. Outlet �` ��"• Style 922 Grooved ��� //- \ Mechanical Tee '. ` ) 1. �� � ie \ 1 I' Outlet ..011______ TA I����� ��1� ry 21/50 mm 2750 mm Hose Clearance Chart Hose Clearance Chart • Dimension Dimension inches inches inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm mm mm• • mum R BendfRadius 0 80 100 125 150 175 R Bend Radius 50 80 100 125 150 175 A Min. 8.4 9.4 10.4 11.4 12.4 13.4 A Min. 6.7 7.7 8.7 9.7 10.7 11.7 � 212 '� 238 263 289 314 339 1 171 197 222 j 247 273 298 j • 10.85 5839 Rev AB Updated 08/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 18 - ✓ctaulrc victaulic.com 5.0 PERFORMANCE— FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hoses with Straight 5.75'7140 mm Reducers CO LISTED Style AB1, AB2, AB4, AB5 and AB10 Brackets Maximum Equivalent Length Number of of 1"/33.7 mm 90°Bends at 2'751 mm Sch.40 Pipe(C=120) Bend Radius inches/mm inches/mm/type feet/meters 31/775 41715/Straight 16/4.9 4 3/4"/20/Straight 17/5.2 4 36/900 Y /15/Straight 21/6.4 1 5 3/4"/20/Straight __. 23/7.0 5 48/1200 /e715/Straight 32/9.8 8 g 3 „ - - 8 Yz"/15D/Straig ht 46//14.04.0 10 60/1500 1/4720/Straight 46/14.0 10 -.�72f1800 _- 1/2"/15/Straight 55/16.8 I 12 '.. 1/a"/20/Straight 53/16.2 12 Series AH2 and AH2-CC Braided Hose with 90° Low Profile Elbows CO US LISTED Style AB11 VicFlex Bracket i Maximum Equivalent Length Number of of 1'Y33.7 mm 90° Bends at 2'751 mm Sch.40 Pipe Bend Radius inches/mm inches/mm feet/meters 31/775 1/2 i15 24/7.3 4 ' "/20 -_-_ J 24/7.3 4 1. 36/900 ../15 1 -_- 26/7.9 5 J 34"/20 28/8.5 5 48/1200 ' /15 43/13.1 8 ___,__ 1/4"/20 l 42/12.8 8 ' - -- - /2'/15 49/14.9 10 60/1500 _ 3"/20 lI 50/15.2 10 72/1800 W/15 65/19.8 12 I 1_ 3/4720 1 63/19.2 12 • 10.85 5839 Rev AS Updated 08/2017 ®2017 Victaulic Company.AU rights reserved. victaulic.com 19 ✓ctaulic victaulic.com • • 5.0 PERFORMANCE — FRICTION LOSS DATA (Continued) Series AH2 and AH2-CC Braided Hoses Equivalent Length Design Guide Equivalent length values at various numbers of 90 degree bends at 2"/51 mm center line bend radius • Length of Stainless Steel Flexible Outlet 1 2 3 4 5 6 7 8 9 10 11 12 Hose Size Bend Bends Bends Bends Bends Bends Bends Bends Bends Bends Bends Bends inches/ inches/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ mm mm meters meters meters meters meters ' meters meters meters meters meters meters meters • ' /15 8.5/2.6 11.0/3.4 13.0/4.0 16.0/4.9 NA NA NA NA _ N.A N.A N.A N.A 31/775 14720 10.0/3.0 12.5/3.8 14.0/4.3 17.0/5.2t N.A N.A N.A N.A N.A N.A N.A N.A 36/900 14 /15 13.5/4.1 16.0/4.9 1 8 0/5.5 19.0/5.8 21.0/6.4 N.A N.A N.A N.A N.A j N.A N.A '/20 14.0/4.3 17.0/5.2 19.5/5.9 20.0/6.1 23.0/7.0 N.A N.A N.A N.A N.A N.A N.A '/2/15 15.5/4.7 17.0/5.2 19.5/5.9 20.0/6.1 21.0/6.4 22.0/6.7 28.0/8.5 32.0/9.8 N.A N.A N.A N.A • 48/1200 __- 60/1500 /20 17.0/5.2 19.0/5.8 21.5/6.6 24.5/7.5 26.0/7.9 27.0/8.2 30.0/9.1 37.0/11.3 N.A N.A N.A N.A 3/q ii 0/ "/15 715/6.6 24.0/7.3 270/8.2 j 28.5/8.7 30.0/9.1 31.0/9.4 37.0/11.3 42,0/12.8 44.0/13.4 46.0/14.0 N.A NA 3/4/20 23.0/7.0 24.0/7.3 28.0/8.5 29.5/9.0 30.5/9.3 31.0/9.4 38.0/11.6 42.0/17.8 44.0/13.4 46.0/14.0 N.A N.A 72/1800 -- 42.0/12.8 46.0/14.0 49.0/14.9 52.0/15.8 54.0/16.5 55.0/168/z"/15 30.0/9.1 32.0/9.8 36.5.11.1 37.5/11.4 40.5/12.5 41.0/12.8 14720 32.0/9.8 32.5/9.9 35.0/10.7 35.5/10.8 40.0/12.3 40.5/12.3 141.0/12.5 46.0/14.0 50.0/15.2 51.0/15.5 52.0/15.8 53.0/16.2 J NOTES: • Values for use with 5.75"/140 mm straight reducers. How to use this Design Guide: • For some systems,it may be advantageous for the designer to calculate the system hydraulics using shorter equivalent lengths associated with fewer than the maximum allowable number of bends.In this case,the designer may select a design number of bends for the job and use the associated equivalent length from the design guide to determine the system hydraulics. • It is possible that the actual installed condition of some of the flexible drops may have more bends than the designer selected.When this happens,the design guide may be used to find equivalent lengths based on the actual installed number of bends for particular sprinkler installations.The system hydraulics can be recalculated using actual equivalent lengths to verify the performance of the system. • • 10.85 5839 Rev AB Updated 08/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 20 ✓ctaulrc victaulic.com 5.1 PERFORMANCE — FRICTION LOSS DATA ® Series AH2 and AH2-CC Braided Hoses Style AB1, AB2, AB3, AB4, AB5, AB7, AB7 Adj., AB8, AB10 and AB12 VicFlex Brackets Maximum 1 Equivalent Number Length of Length of of 90°Bends Stainless Steel Outlet 1"/33.7mm at 77178mm Flexible Hose K-Factor Size Sch.40 Pipe Bend Radius inches/mm Imperial/S.I. inches/mm/type feet/meters '__ /15/Strai ht 23.5/7.1 31/775 5.6/8.1 1^/15/90°Elbow i 23.5/7.1 2 "/15/Strai ht 27.8/8.5 36/900 5 6/8 1 -- 9 -- ---- 2 _-. __. _- . __. �_-_ _ =/15/90°Elbow . 25.6/7.8 _ / /15/Straight 38.2/11.6 I 48/1200 5.6/8.1 3 / �/15/90°.Elbow 30.7/9.3 __ �/715/Straight __ __ 42.4/12.9 60/1500 5.6/8.1 -'Vz"/15/90`Elbow 35.9/10.9 4 h'Y15/Strai ht_ 46.6/14.2 r 72/1800 5.6/8.1 "/15/90°Elbow 41.1/12.5 i 4 ' 3/4 720/Strai ht 16.8/5.1 31/775 8.0/11.5 - - - ---...----- -- , 2 a 3'" 20/90°Elbow 16.8/5.1 3//20/Straight 7 20/6.0 36/900 8.0/11.5 ! 2 3/a"720/90°Elbow. ... 19.7/6.0 /4"/20/Strai ht __ 27.8/8.4 48/1200 8.0/11.5 -----3 - -_. ____.___-__-. 3 720/90'Elbow 26.6/8.1 3/4"/20/Straight 35.7/10.9 60/1500 8.0/11.5 --- 4 N720/90°Elbow 33.6/10.2 3q 72/1800 8.0/11.5 /720/Straight- 43.5/13.2 4 / 3 !20/90`Elbow 40.6/12.2 -__- -- - - 3/a%20/Straight 16.5/5.0 31/775 11.2/16.1 __ --- 2 3/4720/9M Elbow 17.8/5.4 3/ 720/Straight ---_- 26.7/8.1 Elbow 20.7/6. 3/ 36/900 11 2/16.1 2 48/1200 11.2/16.1 3 W/20/90°Elbow 27.9/8.5 /_ °/20/Stral ht__ 33.9/10.3 3 60/1500 112/161 - ' - 4 } 1/4/20/9M Elbow 35/10.7 72/1800 11.2/16.1 ( 3/4720/Straight 413/12.5 J 4 -, 3/4/20/90°Elbow 42.2/12.8 ` 31/775 14.0/20.2 3/4720/Straight 14.9/4.5 2 -- 3/4"/20/9M Elbow 15.5/4.72 1720/Straight 19.4/5.9I 36/900 14.0/20.2 3/4720/90°Elbow -- ~-- 19.6/5.9� 2 -; " 3 3/ °/20/Straight 30.3/9.2 48/1200 14.0/20.2 - - /a -- - - 3 III ..._.. --- 20/90°Elbow 29.5/8.9 3/4"/20/Straight 33.9/10.3 60/1500 14.0/20.2 4 3/a720/90°Elbow 34.1/10A 3/'/20/Strai9— ht 37.5/11.4 72/1800 14.0/20.2 �- - 1 4 I - ± 3/a'/20/90°Elbow 38.6/11.7 FM NOTES: • Series AH2 has been tested and Approved by FM Global for use in wet,dry and preaction systems per NFPA 13, 13R,and 13D and FM data sheets 2-0,2-5, and 2-8.FM 1637 and Vds standards for safety include,but are not limited to,pressure cycling,corrosion resistance,flow characterisitics,vibration resistance, leakage,mechanical and hydrostatic strength. • Differences in equivalent lengths are due to varying test methods,per FM 1637 and Vds standards.Refer to these standards for additional information regarding friction loss test methods. • EXAMPLE:A 48-inch hose installed with two 30°bends and two 90°bends at a 7-inch bend radius is permitted and considered equivalent to the data in the table shown above.In this example,the total number of degrees is 240°,which is less than the allowable 270°. • • 10.85 5839 Rev AB Updated 08/2017 ®2017 Victaulic Company.All rights reserved. victaulic.com 21 ictaulic` victaulic.com 5.2 PERFORMANCE — FRICTION LOSS DATA ® Series AH2 Braided Hose with 90° Low Profile Elbows Style AB5, AB11 and AB12 VicFlex Bracket Maximum Equivalent Number Length of Length of of 90°Bends Stainless Steel Outlet 1733.7mm at 77178mm Flexible Hose K-Factor Size Sch.40 Pipe Bend Radius inches/mm Imperial/S.I. inches/mm feet/meters L 31/775 5.6/8.1 I 1/2"/15 13.7/4.2 2 36/900 5.6/8.1 1/2"/15 17.0/5.2 2 48/1200 5.6/8.1 1/�"/15 25.0/7.6 3 60/1500 5.6/8.1 V2"/15 33.0/10.1 4 r 72/1800 5.6/8.1 1/2"115 41.1/12.5 4 31/775 ! 8.0/11.5 ' '/20 13.6/4.14 2 36/900 j 8.0/11.5 3/4720 16.9/5.2 2 48/1200 8.0/11.5 '/20 27.8/8.5 3 ---- 60/1500 8.0/11.5 /e"120 32.6/9.9 4 3 72/1800 8.0/11.5 W/20 40.6/12.4 4 31/775 11.2/16.1 3/4720 13.7/4.2 2 • 36/900 __- 11.2/16.1 '/20 17.0/5.2 2 3 r- 4$4200 112/16.1 3/4"/20 24.9/7.6 3 60/1500 11.2/16.1 3/4720 32.9/10.0 4 72/1800 1+ 112/16.1 34720 40.9/125 4 31/775 14.0/20.2 3/4720 13.5/4.1 2 36/900 14.0/20.2 3/4'/20 16.8/5.1 2 48/1200 14.0/20.2 W/20 24.7/7.5 3 60/1500 14.0/20.2 34720 32.7/9.9 4 72/1800 14.0/20.2 3/4720 40.7/12.4 4 FM NOTES: • Series AH2 has been tested and Approved by FM Global for use in wet,dry and preaction systems per NFPA 13, 13R,and 13D and FM data sheets 2-0,2-5, and 2-8.FM 1637 and Vds standards for safety include,but are not limited to,pressure cycling,corrosion resistance,flow characterisitics,vibration resistance, leakage,mechanical and hydrostatic strength. • Differences in equivalent lengths are due to varying test methods,per FM 1637 and VdS standards.Refer to these standards for additional information regarding friction loss test methods. • EXAMPLE:A 48-inch hose installed with two 30°bends and two 90°bends at a 7-inch bend radius is permitted and considered equivalent to the data in the table shown above.In this example,the total number of degrees is 240°,which is less than the allowable 270°. 10.85 5839 Rev AB Updated 08/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 22 \ctaulrc" victaulic.com • 6.0 NOTIFICATIONS WARNINr• i • It is the responsibility of the system designer to verify suitability of 300-series stainless steel flexible hose for use with the intended fluid media within the piping system and external environments. • The effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on 300-series stainless steel flexible hose must be evaluated by the material specifier to confirm system life will be acceptable for the intended service. Failure to follow these instructions could cause product failure, resulting in serious personal injury and/or property damage. NOTE • The VicFlex/"Series AH2 Hose has been tested and evaluated by Spears®for acceptable use with Spears®CPVC Products and is therefore covered under the Spears®FlameGaurd®Installer Protection Plan. 7.0 REFERENCE MATERIALS — CHARACTERISTICS Flexible Hose In-Plane Bend Characteristics One Bend Two Bends Three Bends 2X Minimum Minimum Minimum bend radius bend radius bend radius Minimum OR OR bend radius 90" Minimum bend radius Min mum Minimum ( {bend radius bend radius Minimum \\\ bend radius \�-- Minimum \� bend radus NOTE For out-of-plane (three-dimensional) bends, care must be taken to avoid imparting torque on the hose. I-VicFlex-ABit-AB2-AB10 I-VicFlex-AB3 1-Vic Ilex-A87 I-VicFlex-AB8 I-VicFlex AB4 AB9 I-Vic Fl ex-AB12 • User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products fora particular end-use application,in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications,and the applicable building codes and related Victaulic reserves the right to change product specifications,designs and standard regulations as well as Victaulic performance,maintenance,safety,and warning equipment without notice and without incurring obligations. instructions.Nothing in this or any other document,nor any verbal recommendation, Installation advice,or opinion from any Victaulic employee,shall be deemed to alter,vary,supersede, Reference should always be made to I-VICFLEX-AB1-AB2-AB10,I-VICFLEX-AB4-AB9, or waive any provision of Victaulic Company's standard conditions of sale,installation I-VICFLEX-AB7,or I-VICFLEX-AB8 for the product you are installing.Handbooks are guide,or this disclaimer. included with each shipment of Victaulic products for complete installation and assembly Intellectual Property Rights data,and are available in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warranty product,service,or design is intended,or should be constructed,to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patent or other intellectual property right of Victaulic or any of its subsidaries or affiliates covering such use or design,or as a recommendation for the use of such Trademarks material,product,service,or design in the infringement of any patentor other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right.The terms"Patented"or"Patent Pending"refer to design or utility patents Victaulic Company,and/or its affiliated entities,in the U.S.and/or other countries. • • or patent applications for articles and/or methods of use in the United States and/or other countries. • 10.85 5839 Rev AB Updated 08/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 24 ✓ctaulic" Sprinkler Heads Bulletin 014 October 2020 co Model Fl FR Series c ReIiabk ® Quick Response o Glass Bulb Sprinklers o 0 0 Cr Model F1FR56 Sprinkler Types t `., Standard Spray Upright � • o Standard Spray Pendent o Conventional Upright/Pendenteli Vertical Sidewall * = j ec'" Horizontal Sidewall �yr ` ciT Model F1FR56 Recessed Sprinkler Types Upright Pendent Conventional Standard Spray Pendent Horizontal Sidewall Model F1FR56 Concealed Sprinkler Types ti� Standard Spray Pendent Model F1FR42, F1FRXLH & F1FR28 Sprinkler ., , Types Standard Spray Upright Vertical Sidewall Horizontal Sidewall Recessed Pendent/F1/F2 Standard Spray Pendent Model F1 FR40 Sprinkler Types Standard Spray Pendent a•, 4 Model F1 FR42, F1 FR40, F1 FRXLH & F1 FR28 # i. Recessed Sprinkler Types . ;.; �^, �' Standard Spray Pendent !`:. '.+'•. Model F1 FR56LL&F1 FR42LL Low Lead Sprinkler Recessed Concealed Recessed Types Horizontal Sidewall Pendent Pendent/FP Standard Spray Pendent with less than 0.25% Lead _ Content ili i,__ Listing &Approvals (5 The following organizations provide Listings or Approvals vw` for various Model F1FR series sprinklers. See the Design and Installation table in this Bulletin for information on XLH Upright XLH Pendent XLH Recessed specific listings and approvals applicable to each sprin- PendentFl/F2 kler. Product Description 1. Underwriters Laboratories Inc. and Certified for Canada (cULus) in accordance with ANSI/UL199. Reliable Model F1FR series sprinklers 2. FM Approvals (FM) are quick-response automatic sprin- ' - ,, 3. Loss Prevention Certification Board (LPCB) klers with a glass bulb thermal element. 4. VdS Schadenverhutung GmbH (VdS) Model prayF1F series sprinklers are Stan 5. Underwriters Laboratories Inc. and Underwriters dard Spray sprinklers, with the excep- tional Laboratories of Canada Certified for Health Effects tion of the Model F1FR56 Conventional XLH Recessed to NSF/ANSI Standard 61 Annex G (ULH) sprinkler which is an Old-style/Conven- Pendent FP tional sprinkler. 6. EC Certificate: 0786-CPD-40239 (RA1414), 0786- The Model F1FR Series automatic sprinklers utilize a 3.0 CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) mm frangible glass bulb.These sprinklers have demonstrat- e (EC) ed response times in laboratory tests which are five to ten 7. WaterMark certified. Certificate Number 23347. times faster than standard response sprinklers. This quick (WM) response enables the Model F1FR Series sprinklers to apply UL Listing Category water to a fire faster than standard-response sprinklers of the Sprinklers,Automatic&Open(VNIV) same temperature rating. Quick Response Sprinkler The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid Model F1FR Series sprinklers must be installed 1vith the in both the liquid and vapor phases. The vapor phase can Reliable sprinkler installation wrench identified in the Design' , be seen as a small bubble. As heat is applied, the liquid and Installation Information table in this Bulletin. Any other expands, forcing the bubble smaller and smaller as the liq- wrench may damage the sprinkler. A leak tight sprinkler joint uid pressure increases. Continued heating forces the liquid can be obtained with a torque of 8 to 18 lb-ft(11 to 24 N-m). to push out against the bulb, causing the glass to shatter, Do not tighten sprinklers over the maximum recommended opening the waterway and allowing the deflector to distrib- installation torque. Exceeding the maximum recommended ute the discharging water. installation torque may cause leakage or impairment of the Model F1FR Series sprinklers provide a wide range of op- sprinkler. tions where quick-response, glass bulb sprinklers are used: Recessed Sprinklers • Pendent, recessed pendent, upright, horizontal Model F1FR Series Recessed sprinklers are to be installed sidewall, and vertical sidewall deflectors as shown in Fig. 1, Fig.2,or Fig.3,as applicable to the spe- • K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 cific model being installed.The Recessed Escutcheon Data metric), and 5.6 (80 metric) table in the Bulletin identifies the only recessed escutcheons • Flush, recessed, and concealed installations that are permitted to be used with each Model F1FR Series See the Design and Installation Information table in this Recessed sprinkler.The use of any other recessed escutch- Bulletin for information on the approvals and availability of eon will void all approvals and negate all warranties. specific Model F1FR series sprinkler configurations. Concealed Sprinklers Model F1FR Recessed Pendent and Recessed Horizon- Model F1FR Series Concealed Pendent sprinklers are to tal Sidewall sprinklers are required to be used with Reliable be installed as shown in Fig.4 or Fig.5,as applicable to the Model F1, F2, or FP recessed escutcheons. See the Re- selected cover plate. Model F1FR56 Concealed Pendent cessed Escutcheon Data table in this Bulletin for listing and and Model F1 FR56LL Concealed Pendent sprinklers have approval information with each specific Model F1FR series a factory-installed Model CCP cup. A protective cap is in- sprinkler.Model F1 and F2 recessed escutcheons,shown in stalled at the factory that should remain on the sprinkler until Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch the sprinkler is installed and should then be reinstalled on (19mm) and 1/2-inch (12.7mm)of adjustment, respectively. the sprinkler until the cover plate is installed.The concealed Model FP recessed escutcheons, shown in Fig. 2, provide a sprinkler assemblies are completed by the installation of a 1/2-inch(12.7mm)threaded adjustment. Model CCP push-on/thread-off cover plate assembly. The Model F1 FR56 Concealed Pendent and Model F1 FR56LL cover plate and sprinkler cup assemblies are joined using Concealed Pendent sprinklers are required to be used with a cover plate skirt with flexible tabs for threaded engage- Model CCP cover plates.A standard profile Model CCP coy- ment. A choice of two Model CCP cover plate assemblies er plate is available that provides up to 1/2-inch(12.7mm)of provides either 1/2-inch (13mm)or 5/8-inch (8mm)of cover cover plate adjustment. In addition,a low profile Model CCP adjustment. Do not install Model F1FR Series Concealed cover plate is also available that provides up to 5/16-inch Pendent sprinklers in ceilings which have positive pressure (8.0mm)of cover plate adjustment. See the Design and In- in the space above. stallation Information and Listed and Approved Temperature Model F1FR Series Concealed Pendent sprinklers require a Ratings tables in this Bulletin for further information on ap- 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The proved cover plate options. Model GFR2 wrench is used to engage the sprinkler wrench- Application ing surfaces and to install the sprinkler in the fitting.Remove the Model F1FR Series sprinklers are intended for use in protective cap to install the sprinkler,then reinstall the protective accordance with NFPA 13, FM Property Loss Prevention cap until the cover plate is installed. When inserting or remov- Data Sheets, and the requirements of the Authority Hay- ing the wrench from the sprinkler/cup assembly,care should be ing Jurisdiction. Care must be exercised that the k-factor, taken to prevent damage to the sprinkler. Do not wrench any temperature rating, deflector style,and sprinkler type are other part of the sprinkler/cup assembly. Installation is corn- in accordance with the requirements of the applicable pleted by removing the protective cap from the sprinkler and design and installation standards. In addition, Model pushing the cover plate onto the cup.Final adjustment is made F1FR Series sprinklers must be used in accordance with by hand turning the cover plate until the skirt flange makes full their listings and approvals, as well as the information contact with the ceiling.Cover plate removal requires turning the provided in this Bulletin. cover plate in the counter clockwise direction.After installation, Installation inspect all sprinklers to ensure that there is a gap between the Glass bulb sprinklers have orange bulb protectors or pro- cover plate and ceiling and that the four cup slots are open and tective caps to minimize bulb damage during shipping,han- free from any air flow impediment to the space above. dling and installation. Reliable sprinkler installation wrench- Concealed cover plate/cup assemblies are listed only for es are designed to install sprinklers with bulb protectors in use with specific sprinklers.The use of any concealed cover place.Remove the bulb protector at the time when the sprin plate/cup assembly other than the Reliable Model CCP with kler system is placed in service for fire protection. Removal Model Fi FR56 Concealed Pendent and Model Fi FR56LL of the bulb protector before this time may leave the bulb vul- Concealed Pendent sprinklers or the use of the Model CCP nerable to damage.Remove bulb protectors by undoing the Concealed cover plate assembly on any sprinkler with clasp by hand. Do not use tools to remove bulb protectors. which it is not specifically listed my prevent good fire pro- tection and will void all guarantees, warranties, listings and approvals. 2. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414& RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Nominal Nominal Nominal Orifice Sprinkler Listings Model K-factor Diameter Deflector/ Height Installation SIN and Approval Orientation Wrench Notes Approvals US Metric inches mm inches mm Pendent 2.25 57 W2 RA1411 cULus 2 F1FR28 2.8 40 3/8 10 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 Upright 2.25 57 W2 RA1421 cULus 1,2 F1FR40 4.0 57 3/8 10 Pendent 2.25 57 W2 RA1418 VdS Recessed Pendent 2.25 57 GFR2 RA1418 VdS Pendent 2.25 57 W2 RA1413 cULus 2 F1FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 W2 RA1423 cULus 1,2 F1FR42LL 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1410 cULus, ULH Recessed Pendent 2.25 57 GFR2 RA1410 cULus, ULH F1FRXLH Pendent 2.25 57 W2 RA1413 cULus 2 (F1FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 with Pintle) Upright 2.25 57 W2 RA1423 cULus 1,2 cULus, FM, Pendent 2.25 57 W2 RA1414 LPCB,VdS,EC, 1,2,3,4 WM cULus, FM, Recessed Pendent 2.25 57 GFR2 RA1414 LPCB,VdS,EC, 1,2,3,4 WM 66 4-03 80 1/2 15 Concealed Pendent 2.25 57 GFR2 RA1414 cULus,,/VMS,EC, 5,6 cULus,FM, P VdS,EC, 1pright 2.25 57 W2 RA1425 LPCB, 1,2,3,4 WM "Conventional 2.25 57 W2 RA1475 LPCB,VdS,EC, 4 (Pendent or Upright)" WM Pendent 2.25 57 W2 RA1415 cULus, ULH 1 F1FR56LL 5.6 80 1/2 15 Recessed Pendent 2.25 57 GFR2 RA1415 cULus, ULH Concealed Pendent 2.25 57 GFR2 RA1415 cULus,ULH 6 Horizontal Sidewall 2.63 67 W2 RA1435 cULus,FM 1,2,3,7 F1FR56 5.6 80 1/2 15 Recessed Horizontal 2.63 67 GFR2 RA1435 cULus,FM 8 Sidewall F1FR56 5.6 80 1/2 15 Vertical Sidewall 2 25 57 W2 RA1485 cULus,FM, 1,2,3,9 (Pendent or Upright) LPCB cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. (2)cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. (3)Available with FM approved Polyester coating in black or white. (4)Available with LPCB and VdS approved Polyester coating. (6)VdS and EC approvals of the F1FR56 Concealed Pendent sprinkler are for 155°F(68°C)temperature rated sprinklers only.VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2-inch(12.7mm)adjustment Model CCP cover plate only. (6)Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch(12.7mm)of adjustment or low profile with 5/16-inch(8.0 mm)of adjustment. cULus Listing of the F1FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. Minimum to maximum deflector to ceiling distance shall be 4 inches to 12 inches(102mm to 305mm).FM Approval of the F1FR56 Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (6)cULus Listing and FM Approval of the F1FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (9)The F1FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. Listed and Approved Temperature Ratings Ordinary Temp. Intermediate Temp. High Temp. Classification Classification Classification Deflector/ 100°F(38°C) Max.Ambient 150°F(65°C)Max.Ambient 225°F(107°C) Max. Model Orientation Temp. Temp. Ambient Temp. 135°F(57°C) 155°F(68°C) 175°F(79°C) 200°F(93°C) 286°F(141°C)Temp. Temp.Rating Temp. Rating Temp. Rating Temp.Rating Rating Orange Bulb Red Bulb Yellow Bulb Green Bulb Blue Bulb Pendent cULus F1FR28 Recessed Pendent cULus Upright cULus F1FR40 Pendent VdS Recessed Pendent VdS Pendent cULus F1FR42 Recessed Pendent cULus Upright cULus F1FR42LL Pendent cULus, ULH Recessed Pendent cULus,ULH Pendent cULus F1 FRXLH Recessed Pendent cULus I Upright cULus Pendent cULus, FM,LPCB,VdS,EC,WM Recessed Pendent cULus, FM, LPCB,VdS, EC,WM F1FR56 Concealed Pendent* cULus,WM cULuVMS,EC, cULus,WM Upright cULus,FM, LPCB,VdS, EC,WM "Conventional LPCB,VdS, EC,WM (Pendent or Upright)" Pendent cULus, ULH F1FR56LL Recessed Pendent cULus, ULH Concealed Pendent* cULus, ULH Horizontal Sidewall cULus,FM F1FR56 Recessed Horizontal cULus, FM Sidewall F1FR56 Vertical Sidewall(Pen- cULus,FM, LPCB dent or Upright) * Model F1FR56 Concealed Pendent and F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F(74°C) temperature rated cover plate. Recessed Escutcheon Data Listed and Approved Recessed Escutcheons Deflector/ Model F1 Model F2 Model FP Model Orientation (Fig. 1 &3) (Fig. 1 &3) (Fig.2) SIN 3/4-inch (19mm) 1/2-inch (12.7mm) 1/2-inch(12.7mm) adjustment adjustment adjustment F1FR28 Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 F1FR42LL Recessed Pendent cULus,ULH cULus, ULH cULus, ULH RA1410 F1FR42XLH Recessed Pendent cULus cULus cULus RA1413 cULus, LPCB,VdS, cULus, FM, LPCB, F1FR56 Recessed Pendent cULus,VdS,EC,WM RA1414 EC,WM VdS,EC,WM F1FR56LL Recessed Pendent cULus,ULH cULus,ULH cULus, ULH RA1415 F1FR56 Recessed Horizontal Sidewall cULus cULus,FM cULus RA1435 4. , 2 1/4"HOLE DIA. [57.2mm] _ 1 15/16"DIA [49.2mm] r _i—--i7 11 TURN COLLAR I 1"X 1/2" REDUCER UNTIL TIGHT AGAINST SPRINKLER t FACE OF FITTING WRENCH BOSS \ l \ I / TO FACE OF CEILING DIMENSION II E1 ESCUTCHEON II �—=- II AT MAXIMUM RECESS = 1[25.4mm] 7:7, h: J AT MINIMUM RECESS = 3/8[9.5mm] Ff ESCUTCHEON jl/�// —. F2 ESCUTCHEON 3/4[19mm] 1�j �11 i,=7, AT MAXIMUM RECESS = 3/4[19mm] ADJUSTMENT - AT MINIMUM RECESS = 3/8(9.5mm] F2 ESCUTCHEON all' 03SVel lI 1 � III 1 /% 1/2(i2.7mm] w 1161 �'4 /_' ADJUSTMENT III ILL F7 ESCUTCHEON dV, i ii 1/8" AT MAXIMUM RECESS = 7/8(22.2mm] 11 1111 [3.2mm] AT MINIMUM RECESS = 1-5/8(41.3mm] f2 ESCUTCHEON �i. 11 .P AT MAXIMUM RECESS = 1-1/8728.6mm] `/1 1/ ♦��I AT MINIMUM RECESS = 1-5/8741.3mm] 2 27/32"DIA. [72.2mm] Fig. 1 Model F1 FR56,F1 FR56LL,F1 FR42,F1 FR40,F1 FR42LL,F1 FRXLH&F1 FR28 Recessed Pendent sprinkler with Model Fl or F2 escutcheon I I 1 1" X 1/2" REDUCER 2 5/8" OL4 [66.7mm] HOLE IN CEILING 2 58.7mmA.DI A.16" / [58.7mm] CUP II L �� J CEILING �'. FACE OF FITTING v`I TO FACE OF CEILING _ __ ���,___ ,h L DIMENSION 1 a IIIpIl`igi T AT MAXIMUM RECESS = 1-1/2[38mm] 1.. I'uiti, AT MINIMUM RECESS = 1[25.4mm] 0 ` ' AT MAXIMUM RECESS = 9/16[14.3mm] %2[12.7mm] "RR 7, AT MINIMUM RECESS = 1[25.4mm] ADJUSTMENT ,,,. am ..., I* 3 1/4 DIA. (82.6mm] Fig.2 Model F1FR56,F1FR56LL,F1FR42,F1 FR40,F1FR42LL,F1FRXLH&F1FR28 Recessed Pendent sprinkler with Model FP escutcheon 5. FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON j/ //1 AT MAXIMUM RECESS = 1[25.4mm] F7 ESCUTCHEON AT MINIMUM RECESS = 3/8(9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-3/8[34.9mmj AT MAXIMUM RECESS = 3/4[19mm] AT MINIMUM RECESS = 2-1/16[52.4mm] AT MINIMUM RECESS = 3/8'[9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8[41.3mmj 2 1/4" HOLE DIA. f 1/8„ AT MINIMUM RECESS = 2-1/16[52.4mm] [57.2mm j [3.2mm] 1" X 1/2" REDUCER \ i..r__r1\_I r—� pp1 i 4"—12" 1 15/16" DIA. IF IliI'I1I�I111=-- •' I wµ�_—_ —_�;. [101.6mm-304.8mm] [49.2mm] mu pd II I " 2 27/32" DIA. CEILING TO i IC III'ill mn [72.2mm] DEFLECTOR a TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER \\.WRENCH BOSS. Fl ESCUTCHEON 3/4[l9mmj ADJUSTMENT f F2 ESCUTCHEON 1/2[12.7mm] ADJUSTMENT D,s r RECESSED HSW W/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" — 6" [101.6MM — 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig.3 Model F1 FR56 Recessed Horizontal Sidewall sprinkler with Model F1 or F2 escutcheon 1 " x 1/2" REDUCING TEE OR ELBOW T IT -- -------4--------+--------4------ - - 2 5/8" DIA. 2 5/76" DIA - HOLE IN CEILING --.. — CUP 4M; - IrIILaJi11�� 1 1/2" MAX. "" "' FACE OF FITTING �������� cud o�� //''V///I TO FACE OF CEILING 'O I;�' �I fiiiiiii; DIMENSION CEILING , \ . / � /// //./> 7/2" MAX. 15/76' COVER ADJUSTMENT COVER PLATE ASSEMBLY /- 3 5/76" DIA. SPRINKLER / CONCEALED, 1/2" ADJUSTMENT 017FGO1A Fig.4 Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch(12.7mm)adjustment-Model CCP cover plate 6. 1" x 1/2" REDUCING TEE OR ELBOW IT_ 2 5/8" DIA. 2 5/16" DIA '' _- HOLE IN CEILING J CUP t ill Ii II 1 1/2 MAX. FACE OF FITTING " ill °�l TO FACE OF CEILING Y I I, r,,,,,,,, DIMENSION c�ii i CEILING ma ""' 5/16" MAX. -- ---p---.. 3/4", COVER ADJUSTMENT COVER PLATE } ASSEMBLY /3 5/16" DIA. SPRINKLER CONCEALED, 5/1 6" ADJUSTMENT 017FCO2A Fig. 5-Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with low profile 5/16-inch (8.0mm) adjustment- Model CCP cover plate Maintenance Material Data The Model F1FR Series sprinklers should be inspected and Frame: DZR Brass,OM Brass,or Low Lead Brass the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water,ammonia or Deflector: CDA Alloy 220,260,or 510 anyother cleaningfluids.Remove dust byusinga soft brush Load Screw\Pintle: CDA Alloy 360 or 544 or gentle vacuuming. Replace any sprinkler which has been Cup: CDA Alloy 651 or 693 painted(other than factory applied)or damaged in any way. Washer: Nickel Alloy 440 or 360,coated with PTFE A stock of spare sprinklers should be maintained to allow Adhesive Tape quick replacement of damaged or operated sprinklers. Bulb: Glass Finishes (1) Standard Finishes Sprinkler Escutcheon Cover plate' Ordering Information Bronze Brass Chrome Specify: Chrome Plated Chrome Plated White 1. Sprinkler Model: [F1 FR28][F1 FR40][F1 FR42] Polyester Coated Yomi White Painted [F1 FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] Special Application Finishes Sprinkler Escutcheon Cover platet't 2. Sprinkler Deflector/Orientation: [Pendent][Recessed Electroless Nickel Electroless Nickel Pendent][Upright][Conventional][Horizontal Sidewall] PTFE' PTFE Bright Brass [Recessed Horizontal Sidewall][Vertical Sidewall] Bright Brassi3i Bright Brass Black Plating 3. Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2] Black Plated Black Plated Black Paint Black Paintw6' Black Paint Off White 4. Sprinkler Temperature Rating: [135°F (57°C)][155°F Off White(2)( e Off White Satin Chrome (68°C)][175°F(79°C)][200°F(93°C)][286°F(141°C)] Chrome Dull Chrome Dull 5. Sprinkler Finish (11 Other finishes and colors are available on special order. Consult the 6. Escutcheon Model: [F1][F2][FP] factory for details.Custom color painted sprinklers may not retain their UL Corrosion resistance listing.Coverplate custom paint is semi-gloss, 7. Escutcheon Finish (where applicable) unless specified otherwise. 8. Cover plate Model: [standard profile CCP 1/2-inch (2) cULus Usted only. (12.7mm) adjustment][low profile CCP 5/16-inch 3 200°F(93°C)maximum. (8.0mm) adjustment] of cULus listed "corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and 9. Cover plate Temperature Rating: [135°F(57°C)for use RA1415 (Pendent) in standard black or white. Corrosion resistance in with Ordinary Temperature sprinklers][165°F (74°C) other polyester colors is available upon request. for use with Intermediate Temperature sprinklers] (5) FM Approvals finish as"Polyester coated"applies to SIN Number RA1414,RA1435 and RA1425 in standard black or white. 10. Cover plate Finish (e)LPCB and VdS Approved finish applies only to RA1425,RA1414,RA1418 (VdS)and RA1475. Note: When Model F1FR Series Recessed sprinklers are ordered, the i'l cULus listed Corrosion Resistant sprinklers and escutcheons are packaged separately. 7. Reliable . . . For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gauges • Electrical sprinkler alarm switches • Identification signs • Water flow detectors • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 100 years. Manufactured by ® Reliable Automatic Sprinkler Co., Inc. Recycled (800)431-1588 Sales Offices Paper (80014)848829--20510421 Salesorporate Offices Fax Co Revision lines indicate updated or new data. (9 ) www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.10/20 pm 9999970300 Hangers and Bracing ® TDLCD • a Land of NIBCO Revision 5/24/2001 Fig. 200 1 gt "Trimline" Adjustable Band Hanger �J Size Range— 1/2 thru 8 inch pipe. o..• C Material—Carbon Steel, Mil. Galvanized to G-90 specifications. c p / Function— For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger ;' • adjustment after installation. % Features • (1/2 thru 2 inch) Flared edges ease installation for all B B pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from A A separating with hanger. Hanger is easily installed around pipe. • (2-1/2 thru 8 inch) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals—Underwriters' Laboratories Listed (1/2" 1/2 THRU 2 INCH PIPE 21/2 THRU 8 INCH PIPE thru 8") in the USA(UL) and Canada (cUL)for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4"thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10, and ,-:4 Manufacturers Standardization Society SP-69, type 10. - Maximum Temperature-650°F. Finish— MD. Galvanized, for Stainless Steel materials order TOLCOTM Fig. 200WON. -- Order By— Figure number and pipe size. i + If'U, Pipe Size Rod Size A B Max. Rec. Approx. Inch Metric* Load Lbs. Wt./100 1/2 3/8 8mm or 10mm 3-1/8 2-5/8 400 11 3/4 3/8 8mm or 10mm 3-1/8 2-1/2 400 11 1 3/8 8mm or 10mm 3-3/8 2-5/8 400 12 1-1/4 3/8 8mm or 10mm 3-3/4 2-7/8 400 13 1-1/2 3/8 8mm or 10mm 3-7/8 2-7/8 400 14 2 3/8 8mm or 10mm 4-1/2 3 400 15 2-1/2 3/8 10mm 5-5/8 4-1/8 600 27 3 3/8 10mm 5-7/8 4 600 29 3-1/2 3/8 10mm 7-3/8 5-1/4 600 34 4 3/8 10mm 7-3/8 5 1000 35 5 1/2 12mm 9-1/8 6-1/4 1250 66 6 1/2 12mm 10-1/8 6-3/4 1250 73 8 1/2 12mm 13-1/8 8-3/4 1250 136 *Order Fig. 200M Main OfficelManufacturing Facility•1375 Sampson Ave.• Corona,CA 92870• Ph: 909.737.5599• Fax: 909.737.0330 Distribution Center• 8790 Fruitridge Road- Sacramento,CA 95826• Ph: 916.388.7800• Fax: 916.388.1401 89 Manufacturing Facility•4851 Homestead Road,Bldg.118• Houston,TX 77028• Ph: 713.672.0058• Fax: 713.672.0074 www.tolco.com Threaded Accessories B .05 - Threaded Rod (right-hand threads - both ends) B320 - Threaded Rod (right& left hand threads) TL Size Range: ' :"-16 thru 3"-4 rod Specify Length �� Material: Steel Function: Recommen•-d for use as a hanger support in hanger assemblies. IL Rod is threaded on both eng with right hand threads of the length shown. Also <. A available with left and right ha threads- specify Fig. R3205L when ordering. - \-Thread Size Maximum Temperature: 750°F (3•1°C) Finish: Plain. Contact customer service •r alternative finishes and materials, Order By: Part number, rod size, length an• i ish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F 1399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-3/8 x'L' 3/8"-16 21/21 (63.5) 'I (3.25) 572 (2.54) B3205-1/2 x'L' 1/2'-13 21/2' (63.5) 1350 6.00) 1057 (4.70) B3205-5/8 x'L' 5/8'-11 21/21 (63.5) 2160 (9.. 1692 (7.52) B3205-3/4 x'L' 3/4'-10 3" (76.2) 3230 (14.37) 2530 (11.25) B3205-1/8 x'L' 7/8"-9 31/21 (88.9) 4480 (19.93) 3508 (15.60) B3205-1 x'L' 1"-8 4" (101.6) 5900 (26.24) ,.20 (20.55) B3205-11/8 x'L' 11/8"-7 41/2" (114.3) 7450 (33.14) 5831 (25.93) B3205-11/4 x'L' 11/4"-7 5" (127.0) 9500 (42.25) 7440 ( '.r9) B3205-11/2 x'L' 11/2"-6 6" (152.4) 13800 (61.38) 10807 (48.07) • B3205-13/4 x'L' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) B3205-2 x'L' 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) B3205-21/4 x'L' 21/4"-41/2 9" (228.6) 32300 (143.67) 25295 (112.51) • 03205-21/2x'1' 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138.64) • B3205-23/4 x'L' 22/4''-4 11" (279.4) 49400 (219.73) 38687 (172.08) B3205-3x'L' 3"-4 12" (304.81 60100 (267.32) 47066 (209.35) ✓ .. :-.. r -.nN.xMYiib'iel4 c nS4t v `5:`a.# .. .•;f.4Y94k. ATR - All Threaded Rod 120" (3.05m) Lengths Fig. 99 - All Threaded Rod Cut To Length Size Range: 3/8"-16 thru 11/2"-6 rod in 120" (3.0bm) lengths or cut to length Material: Steel Maximum Temperature: 750°F 1399°C) ta Finish: Plain. Contact customer service for alternative finishes and materials Order By: Part number, rod Diameter and finish a CO H 2m Part No.-Size x Length Threads Recommended Load Approx.Wt./100 Ft. r a ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) • ATR 1/4"x 120 99-1/4"x length 20 240 11.071 12 (5.44) --------* ATR 3/s"x 120 99-3/8"x length 16 730 13.24) 29 (13.15) ATR 1/2"x 120 99-1/2"x length 13 1350 16.00) 53 (24.04) AIR 5/8"x 120 99-5/8"x length 11 2160 (9.60) 89 140.37) ATR 3/4"x 120 99-3/4"x length 10 3230 (14.37) 123 (55.79) ATR 7/8"x 120 99-7/8"x length 9 4480 119.93) 170 (77.11) ATR 1"x 120 99-1"x length 8 5900 (26.24) 225 1102.06) ATR 11/s"x 120 99-11/s'x length 7 7450 (33.14) 280 1127.01) ATR 11/4"x 120 99-11/4"x length 7 9500 (42.25) 351 1159.21) ATR 11/2"x 120 99-11/z"x length 6 13800 (61.38) 510 (231.33) All dimensions in charts and or drawings are in inches-Dimensions shown in parentheses are in millimeters unless otherwise specified. 13-Line series Pipe Hangers&Supports 238 Eaton SAMMYS° FOR STEEL , SAMMYS° FOR STEEL - Vertical Application Application Product Features 1111 i. •Made with Teks®self-drilling fasteners- no pre-drilling required. • 1 •Installs into steel range from n, 20 gauge-1/2"thicknesses. •Saves time from traditional methods. 1111111:: •Reduces installation costs. • I •Quick to install using the Sammys Nut r WIN f Driver with an 18V cordless drill/driver.} •A standard screwgun with a depth sensitive nosepiece should be used to install Teks. tFor optimal fastener performance,the and have should be a minimum of 6 amps ,` and have an RPM range of 0-2500. 'Ir . n4��t��,1," ® •Manufactured in the U.S.A. ''7C R���yjjj111�111pppa0a www.i�d xiom) Rod Part Scre.v Ultimate UL Test FM Test Min Max Box Case Approvals Model Size Number Descriptions Pullout(Ibs) Load(I bs) Load(lbs) Thick Thick Qty Qty VERTICAL MOUNT 1/4" 8024957 DSTR 100• 1/4-20 x 1"TENS 3 1510 (20 ga.) .036"-20 ga 3/16" 25 125 1/4" 8025957 DST 100 1/4-14 x 1"TEKS 3 446 (20 ga.) .036"-20 ga 3116" 25 125 1/4" 8026957 DST 150 1/4-14 x 1-1/2"TEKS 3 ••0 (16 ga.) 036"-20 ga 3/16" 25 125 1/4" 8027957 DST 200 1/4-14 x 2'TEKS 3 44. 20 ga.) .036"-20 ga 3/16" 25 125 1/4" 8030957 TEK 500 12-24 x 1-112"TEKS 5 3125 t/16") .188"-3/16' 1/2" 25 125 3/8" 8038957 DSTR 1" 1/4-20 x 1"TEKS 3 1510 (21.a.) 1500 1475 .036"-20 ga 3/16" 25 125 3/8" 8037957 DSTR 1-1.'2" 12-24 x 1-1/2"TEKS 5 1510 (3/16' 1500 1475 .060"-16 ga. 112" 25 125 .. 3/8" 8039957 DSTR 516" 5/16.18 x 1.1/4"TEKS 3 2200 (20 ga.) 1500 1475 .036"-20 ga 3116" 25 125 3/8" 8040957 DST 10 114-14 x 1"TEKS 3 446 (20 ga.) .036"-20 ga 3116" 25 125 970 (16 ga.) - 3(8' 8077925 DST 10-SS 114.14 x 1'TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 970 (16 ga.) 3/8" 8041957 DST 15 1/4-14 x 1-1(2"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 #14 Black 970 (16 ga.) Pad#8113910 a ' 318" 8078925 DST 15-SS 114-14 x 1-1/2"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 ` YrT1 970 (16 ga.) ! ._ 3/8" 8042957 DST 20 1/4.14 x 2"TEKS 3 ilw446 (20 ga.) .036"-20 ga 3i16" 25 125 970 (16 ga) ' 446 (20 ga.) 318" 8044957 DST 30 114-14 x 3"TEKS 3 970 (16 g3( .03:"-20 ga 3/16" 25 125 '� 3/8" 8045957 DST 516 5116-16 x 1-114"TEKS 3 1500 (3116') 1500 1475 .125"-1 3/16" 25 125 .250°-114 1/2" 25 125 3/8" 8046957 TEK 50 12-24 z 1-112"TEKS 5 3125 (3/16') 1500 1475 1/2'' 8031925 DST 2.0 1/4-14 x 2"TEKS 3 446 (20 ga.) 188"-3116" 1(4" 25 125 970 (16 ga.) _ 1/2" 8033925 DSTR 1.0" 1/4-20 x 1"TEKS 3 1510 (20 ga.) .036"-20 ga 311." 25 125 1/2" 8034925 DSTR 5.16` 5/16-18 x 1-114"TEKS 3 2220 (20 ga.) .036"-20 as 3116" 25 125 1/2" 8035925 DST 5.16 5/16.18 x 1-1/4"TEKS 3 1500 (3(16") .125'-118" -3/16" 25 125 _ 1/2" 8036925 TEK 5.0 12-24 x 1-1/2'TEKS 5 3125 (3(16") .188"-3/16• 1/2" 125 #14 SW Fred 'Includes retaining nut Nut Driver Part#8114910 ill t D drivers were w ar unique spinoff feh provs a safe installation `\, g�Hs each time.SPECIAL WhenNUT theRIVER face ofSYSTEM:the driverThe comesnut into contact designed with the material ith you are installingature into,whic continue drillingide untilfast nutand driver spins \ free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. For the most up to date information,visit www.itwbuildex.com 6 • t.. ,AH0111,./j2W 0. SIDEWINDER® FOR STEEL - Horizontal Application Application Product Features 1.4 i •Made with Tel a self-drilling fasteners-no pre-drilling required. I •Installs into steel range from 20 gauge—1/2"thicknesses. Ar Ril t„ •A standard screwgun with a depth sensitive nosepiece should be used to OW° install Teks.For optimal fastener performance,the screwgun should be a — - minimum of 6 amps and have an RPM range of 0-2500. •Saves time from traditional methods. •Reduces installation costs. •Quick to install using the Sammys Nut Driver with an g 18V cordless drilLdriver. 1 Watch a ddn demonstration al €6 •Manufactured in the U.S.A. www.ilwbuildex.com) Approvals Rod Part Model Screw Ultimate UL Test FM Test Min Max Box Case Size Number Descriptions Pullout(Ibs) Load(Ibs) Load(Ibs) Thickness Thickness Qty Qty _ HORIZONTAL MOUNT 1/4" 8047957 SWD 100 114-14 x 1"TEKS 3 1477 (16 ga.) .060"-16 ga 3/16" 25 125 1/4' 8049957 SWDR 100* 1/4-20 x 1'TEKS 3 1900 (20 ga.) .036•-20 ga 3/16" 25 125 3/8' 8050957 SWD 10 1/4-14 x 1'TEKS 3 1477 (16 ga.) .060"-16 ga 3/16" 25 125 3/8' 8080925 SWD 10-SS 1/4-14 x 1'TEKS 3 1477 (16 ga.) .060"-16 ga 3/16" 25 125 — 3/8" 8052957 SWD 20 1/4-14 x 2"TEKS 3 1477 (16 ga.) .060"-16 ga 3/16" 25 125 -``" 3/8" 8055957 SWDR 1' 1/4-20 x 1"TEKS 3 1900 (20 ga.) 1500 1475 .036"-20 ga 3/16" 25 125 #14 SW tted --("-(4 3/8" 8054957 SWDR 1-112' 12-24 x 1-1/2"TEKS 5 2375 (3116") 1500 1475 188"-3116" 112" 25 125 Nut Driver A '" 3/8' 8056957 SWDR 516' 5/16-18 x 1-1l4'TEKS 3 2480 (20 ga.) 1500 1475 .036"-20 ga 3116" 25 125 Part#8114910_ 3/8" 8057957 SWT 15 12-24 x 1-1/2"TEKS 5 2375(3116") 188"-3/16" 112" 25 125 'Includes retaining nut SAMMYS SWIVEL HEAD FOR STEEL -Swivel Application Application Product Features .. •Eliminates distortion of threaded rod in sloped roof applications. (Or • Accommodates 3-112 x 12 pitch. • •Installs into angled z-purlin;allows threaded rod to hang plumb. "Allows 17'detection from vertical. �- / •Manufactured in the U.S.A. • ) wed,a aw.o Qempnebation at www.itwbuildex.comI 46 Approvals Rod Part Model Screw Ultimate UL Test FM Test Min Max Box Case Size Number Descriptions Puilaul ems) Load(lbs) Load(Ibs) Thick Thick Qty Qty SWIVEL MOUNT #14 Slack Nut Driver (w�."" 3/8" 8137957 SH-DSTR 1' 1/4.20 X 1 TEKS 3 3220(3/16") t0 1475 .035" 3116" 25 125 Part#8113910 "steel 12-24 x 1-3i4" 1306(452 off Vertical)3/8" 8268957 SH-TEK 50 ( I) 1500(Vertical) 4" 3/16" 1/2" 25 125 TEKS 5 2281 3/15"HSS 850(45°off Vertical) - /2' 1585(3/16"HSS 45'off Vertical) i 1 2366(1i2"steel Vertical) 112" 8270957 SH-TEK 5.0 12-24 x 1-314" 1306(45°off Vertical) 3/16" 25 125 TEKS 5 2281(3/16'HSS) #14 SH Orange 1585(3/16"HSS 45°off Vertical) le Nut Driver .' P,'rt n P273u1c -Does nal comply with ROHS requremen(s;Includes retemrgq nut • 7 To find a distributor near you,call 800-BUILDEX II SAMMYS® FOR WOOD SAMMYS® FOR WOOD - Vertical Application I Application Product Features Not less than Wood Flooring z•nominal MO No pre-drilling required. (1•� ,m/ .11 •Quick to install using the Sammy Not m� Nut Dnver with an 18V cordless 3"nominal drill/driver. thickness(2-112') (depth aside of vertical member) ,__ Product time from traditional I -/ methods. Double Sheetrods Forvedicat ose- Ceiling •Reduces installation costs. Install m center of lower tare. Minimum 2'embedment into tase •Manufactured in the U.SA. • material for NFPA 13 compliance. ,, ` Composite l Truss Consult truss manufacturer for recommended installation point. 4 - "Predntling may be rooked/Cr GST e5-380.Tool available on page if. • r:$ 4 watch a video cremauh bon M www.ltwbufldex.com) Approvals Rod Part Model Screw Ultimate UL Test FM Test Box Cas^ Size Number Descriptions Pullout(Ibs) Load jibs) Load fibs) Qty Cry VERTICAL MOUNT — 114" 8002957 GST 100 114 x 1' 210 (7116"OSB) 25 125 670 (3/4"Ply) • 1/4" 8003957 GST200 1/4 x 2" 1760 (Fir) 25 125 ,J 318" 8007457 GST 10 114 x 1" 210 (7/16'OSB) 300 25 125 670 (3/4"Ply) .Q.`" 3/8" 13008957 GST 20 114 z 2' 1760 (Fir) 850 1475 25 125 3/8' 8068925 GST 20-SS 114 x 2' 1760 (Fir) 850 25 125 #14 Black .Q. 3/8" 8009925 GST 25-380 3/8 a 2-1/2' 2113 (Fir) 1500 25 125 Nut Driver ) , 318" 8010957 GST 30 114 x 3" 2060 (Fir) 1500 1475 25 125 Part#8113910 3/8' 8069925 GST 30-SS 1(4 x 3' 2060 (Fir) 25 125 • i "— 112" 8013925 GST2 1/4x2' 1760 (Fir) 25 125 112" 8015925 GST 3 114 z 3" 2275 (Fir) 25 125 #14 SW Red Nut Driver Part#8114910 r-___, ai v oHS USA SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. For the most up to date information,visit www.itwbuildex.com 4 mimimmimmi . ziAm-AygTo. SIDEWINDER® FOR WOOD -Horizontal Application Application Product Features k Not less than 2"nominal vedth •No pre-drilling required. (1-1/21 up to 3-1/2'pipe;not less than _y...., ." "'—< 3'(2.112)nominal width 4"&5°pipe •Quick to install using the Sammy 4—► Floor Joist Nut Driver with an 18V cordless drill(driver. Minimum 2-112°from bottom for branch lines.Minimum 3°from bot- tom for main lines.Exception:This •Saves time from traditional requirement shall not apply to 2'or methods. thicker nailing strips resting on bop of steel beams. •Reduces installation costs. - •Manufactured in the U.S.A. --- Composite/Truss Consult truss manufacturer for r recommended installation paint. 'Predrillmg may he required for Model SWG 25-380.loot available on page 11. vloalcn a Mao damonsbfion a) Approvals Rod Part Model Screw Ultimate UL Test Box Case Size Number Descriptions Pullout(Ibs) Load fibs) Qty Qty — HORIZONTAL MOUNT 114" 8019957 SWG200 114x2" 1725 (Fir) 25 125 r;; 318" 8020957 SWG 10 1/4 x 1" 622 (Fir) 300 25 125 318" 8021957 SWG 20 114 x 2' 1725 (Fir) 1050 25 125 318" 8073925 SWG 20-SS 1f4 x 2' 1725 (Fir) 850 25 125 �? 318-` 8022925 SWG 25.380 318x2.112" 2249 (Fir) 1500 25 125 #14 SW Red 318" 8023925 SWG 30 1/4 x 3" 1884 (Fir) 25 125 Nut Driver Part#8114910 'May require predrilling'.consult joist maniaruer. SAMMYS SWIVEL HEAD" FOR WOOD - Swivel Application • Application Product Features L .�„�,,.%on •Eliminates distortion of threaded rod. •Accommodates up to 3%"x 12 pitch roof. ` •Allows 17°deflection from vertical. Saves aia Reducestime installatifromtr ondit costs.onl methods. ., awu 0Ajk e w •MIPanufactured in the U.S.A. v Approvals Rod Part Model Screw Ultimate UL Test Load FM Test Min Box Case ,,..-0 Size Number Descriptions Pullout(Ibs) (Ibs) Load(Ibs) Thickness Qty Oty #14 Black - SWIVEL MOUNT 2.Nut Driver - "." 3/8" 8139957 SH-GST 20 1l4 x 2" 1257(Fir) 1050 1475 25 125 „ .�A#8113910 1903 Dim.Lumbe �.e'"°� 1 7s 318"• 8259957 SH-GSTICST 20 5/16 x 1-314" 1406 @ 45'off vertical 1D @ 45° 25 125 Dim.Lumber i i —.... 903 Dim.Lumber 00 112° 8303957 SH-GSTICST 2.0 5116 x 1.3/4" 1406 n 45'o#vertical 25 125 'May require preddlling;consult joist manufacturer. Dim.Lumber 5 #14 SH Orange • Nut Driver Part#827391 D �' • 5 To find a distributor near you,call800-BUILDEX U TO LCD www.tvlca.cmm zoraao'NIBCO Revision 10/24/2001 Fig. 58 - Threaded Side Beam Bracket c®1SUSTEa Size Range— 3/8" rod, pipe sizes 1/2" thru 4" Material — Carbon Steel Function — Practical and economical bracket used to support B.,'"? / piping from wood, concrete or steel beams. Features — Unique design allows rod to be easily threaded into bracket. Offset design permits unlimited rod adjustment. Center mounting hole will accept 3/8" and 1/2" fastener bolts. Per NFPA rn 13: 1/2" thru 2" pipe requires 3/8" fastener, 21/2" thru 4" pipe (�\7 requires 1/2" fastener.* \\�y� A Approvals — Underwriters' Laboratories Listed in the USA(UL) and Canada(cUL), and Factory Mutual Engineering approved thru 4" pipe. A *Note — Additionally UL has listed the Fig. 58 with fasteners as /® shown in table below. �� Finish — Plain Note — Available in Electro-Galvanized finish. Order By — Figure number and finish C *10 UL Listed Fastener Table 2-1/4 x 2 Lag Bolts (No Pre-drilling)Up11 Pipe Size Qty. Fastener Type Material to 4 inch Pipe 2 2 #16 x 2 Drive Screws Wood Per NFPA 1-Lag Bolt Pipe 2 1 3/8 Lag Bolt Wood Up To 4 inch Pipe iie 21-4 1 1/2 Lag Bolt Wood 31 2 1/4 x 11 Lag Bolt Wood 2•#16 x 2 4 2 1/4 x 2 Lag Bolts* Wood Drive Screws 4 2 1/4 x 1 tek screws 14 gauge 1/2 Thru 2 inch Pipe 47 4 2 1/4 x 1 tek screws 16 gauge oi> " No pre-drilling required to i 3,> Dimensions •Weights ;oPipe Rod Max. Rec. Approx.Size Size A BC Load Lbs.* Wt./100 1/2 thru 4 3/8 23/4 1 i 11/s 300 14 `With safety factor of 5. a Tek Type2 Screws Into Min.16Ga.Steel Up To 4 inch Pipe Boll&Flex Nut Up To 4 inch Pipe 1100,i, [kr > 14 OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE.•CORONA,CA 92879•PH 951.737.5599•FAX: 951.737.0330 CUSTOMER SERVICE•800.786.5266 wwwto%o.com TOLCO- Seismic Bracing Fig. 4LA - Longitudinal "In-Line" Sway Brace Attachment 41> Size Range: 1" (25mm)through 12"(300mm) IPS. ® Ca Material: Steel Function: For bracing pipe against sway and seismic disturbance. 4yra or, Approvals: Approved by Factory Mutual Engineering(FM), 1" (25mm)through n ^ 12" (300mm)pipe. j Installation Instructions: Fig.4LA can be used as the system attachment d ' component of a longitudinal or lateral brace assembly. It is intended to be 0 combined with the"bracing member" and TOLCO transitional attachment i A " and structural attachment to form a complete bracing assembly. For fire sprinkler applications NFPA 13 guidelines should be followed. t C V g To Install: Place the Fig.4LA pipe clamp component over the pipe to be braced and tighten down the break-off nuts until the hex head portion breaks 0 off to verify correct installation torque.Next engage brace member(pipe or 4ut-1 thw 4LA-4 S strut) with jaw component and tighten break-off head bolt m until the hex head breaks off to verify correct installation torque. Pivot jaw t. for correct angle and attach to structure using TOLCO brand transitional p.1,14 attachment and structural attachment. 4 a ww x Finish: Plain or Electro-Galvanized.Contact B-Line tope for alternative finishes and materials. K Order By: Figure number,pipe size and finish. [k " w s°k str4 D A 4_ Z , k. c 4LA-5 thru 4LA-12 J/ Pipe Approx. Part Size A i D Bolt Size Wt./100 No. in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kg) 4LA-1 1" (25) 319/32" (91.2) 15/16" (33.5) 15/16" (33.5) 3/8"-16 119 (54.0) 4LA-11/4 11/4" (32) 329/32" (99.3) 13/8" (35.3) 13/8" (35.3) 3/8"-16 123 (55.8) ► 4LA-11/2 11/2" (40) 45/32' (105.7) 11/2" (38.5) 11/2" (38.5) 3/8"-16 127 I (57.6) 4LA-2 2" (50) 511/32" (135.6) 21/32" (51.9) 21/16" (51.9) 3/a"-16 142 (64.4) 4LA-21/2 21/2" (65) 527/32" (148.7) 25/16" (58.5) 25/16" (58.5) 3/8"-16 173 (78.5) 4LA-3 - 3" (80) 61/2" (164.9) 25/8" (66.6) 25/8" (66.6) 3/8"-16 187 (84.8) 4LA-31/2 31/2" (s0) 7.407" (188.1) 27/a" (73.1) 27/a" (73.1) 3/t"-16 198 (89.8) 4LA-4 4" (100) 713/32" (190.8) 31/s" (79.5) 31/8" (79.5) 3/a"-16 209 (94.8) 4LA-5 5" (125) 83/4" (222.3) 35/8" (92.1) 35/8" (92.1) 1/2"-13 298 (135.2) 4LA-6 6" (150) 105/8" (269.9) 49/16" (115.9) 49/16" (115.9) 1/2"-13 521 (236.3) 4LA-8 8" (200) 1213h6" (325.5) 59/1s" (143.7) 521/32" (143.7) 1/2"-13 629 (285.3) 4LA-10 10" (250) 161/2" (419.1) 71/4" (184.2) 71/4" (184.2) 1/2"-13 1320 (598.7) 4LA-12 12" (300) 181/2" (469.9) 81/4" (209.6) 81/4" (209.6) 1/2"-13 1496 (678.6) Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Lane bracing components, resulting in a listed seismic bracing assembly.B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line,except that, in addition to the other exclusions from B-Line's warranty,Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Une by E.T'N 1 71 Pipe Hangers&Supports TOLCOr. Seismic Bracing Fig. 4LA - Longitudinal "In-Line" Sway Brace Attachment cont. ®TOLCO j Longitudinal , Lateral +" Brace •`/- Brace - -- f ' ' m c i « m E N Longitsdinal Loads FM Max.Design Load Max.Rec. H Part Pipe Size 30°-44° 45°-59° 60°-74° 75°-90° Load No. in. (mm) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) 4LA-1 1" (25) 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 1000 (4.45) ILA-11/4 11/4" (32) 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 1000 (4.45) 4LA-11/2 11/2" (40) 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 1000 (4.45) 4LA-2 2" (50) 680 (3.02) 860 (3.82) 1030 (4.58) 1150 (5.11) 1000 (4.45) 4LA-2 1/2 21/2" (65) 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 1000 (4.45) 41A-3 3" (80) 680 (3.02) 970 (4.31) 1190 (5.29) 1320 ! (5.87) 1000 (4.45) - 4LA-31/2 31/2" (90) 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 1000 (4.45) 41A-4 4" (100) 680 (3.02) 970 (4.31) 1190 15.29) 1320 (5.87) 1000 _0.45) 4LA-5 5" (125) - - - - - - - 1600 (7.11) 414-6 6" (150) 1620 (7.20) 2,260 (10.05) 2010 (8.94) 2220 (9.87) 1600 (7,11) 4LA-8 8" (200) 1620 (7.20) 1,660 (7.38) 1570 (6.98) 1740 (7.74) 2015 (8.96) 41A-10 10" (250) 1620 (7.20) 1,660 (7.38) 1570 (6.98) 1740 (7.74) 2765 (12.30 4LA-12 12" (300) 1620 (7.20) 1,660 (7.38) 1570 (6.98) 1740 (7.74) - - Lateral Loads FM Max.Design Load Max.Rec. Part Pipe Size 30°-44° 45°-59° 60°-74° 75°-90° Load No. in. (mm) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) lbs. (kN) 4LA-1 1" (25) 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 1000 (4.45) 4LA-11/4 11/4" (32) 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 1000 (4.45) 4LA-11/2 1112" (40) 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 1000 (4.45) 4LA-2 2" (50) 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 1000 (4.45) 4LA-2 1/2 21/2" (65) 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 1000 (4.45) 41.4-3 3" (80) 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 1000 (4.45) 4LA-3 1/2 31/2" (90) 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 1000 (4.45) 4LA-4 4" (100) 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 1000 (4.45) 4LA-5 5" (125) - - - - - - - - 1600 (7.11) 41A-6 6" (150) 1620 (7.20) 2,300 (10.23) 2820 (12.54) 3140 (13.96) 1600 (7.11) 41A-8 8" (200) 1620 (7.20) 2,300 (10.23) 2820 (12.54) 3140 (13.96) 2015 (8.96) 4LA-10 10" (250) 1620 (7.20) 2,300 (10.23) 2820 (12.54) 3140 (13.96) 2765 (12.30) 414-12 12" (300) 1620 (7.20) 2,300 (10.23) 2820 (12.54) 3140 (13.96) - - Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly.B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line,except that,in addition to the other exclusions from B-Line's warranty,Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Pipe Hangers&Supports 172 by F T•N Seismic Bracing Fig. 980 - Universal Swivel Sway Brace Attachment - 3/8" to 3/4" ®TOLCO Size Range: One size fits bracing pipe 1" (25mm)thru 2"(50mm), Cooper ® B-Line 12 gauge(2.6mm)channel, and all structural steel up to 1/4"(31.7mm)thick. Material: Steel Function: Multi-functional attachment to structure or braced pipe fitting. Features: This product's design incorporates a concentric attachment 980 ii opening which is critical to the performance of structural seismic connections. ® � D NFPA 13 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle. Break off bolt head assures ` 1 verification of proper installation. A B Installation: Fig.980 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and Cooper B-Line/TOLCO "braced pipe" attachment, set sold Included Fig. 1000, 1001,4L,or other TOLCO approved attachment to pipe to form a complete bracing assembly.NFPA 13 guidelines should be followed. Mounting Hardware Is Not Included To Install: Place the Fig.980 onto the"bracing pipe".Tighten the set bolt until the head breaks off.Attachment can pivot for adjustment to proper brace angle. . Approvals: —Approved by Factory Mutual Engineering (FM). i For UL Listed information refer to page 60. 1 , f Note: Fig.980 Swivel Attachment and Fig. 1000, 1001,4L or other TOLCO approved attachment to pipe that make up a sway brace system of UL Listed — attachments and bracing materials which satisfies the requirements of Underwriters Laboratories and the National Fire Protection Association(NFPA) Finish: Plain.Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number and finish. Fig.980 Pat.#6,273,372,Pat.#6,517,030,Pat.#6,953,174, yr 0IF Pat.#6,708,930,Pat.#7,191,987,Pat.#7,441,730, Pat.#7,669,806 Designed to meet or exceed requirements of FM DS 2-8. Fig.4L (1140V Lateral Brace �`'` Longitudinal Brace 4, I Part Max.Design Load***(FM) Approx. Number A B D** 30°-44° 45°-59° 60°-74° 75°-90° Wt./100 in. (mm) in. (mm) in. (mm) lbs./(kN) lbs.!(kN) lbs./(kN) lbs./(kN) lbs. (kg) 980-3/8 51/4" (133.3) 17/8" (47.6) 13/32" (10.3) 133 (60.3) I. 980-1/2* 51/4" (133.3) 17/8" (47 6) 17/32" (13.5) 1590 2260 2720 3040 132 i (59.7) 980-5/8 51/4" (133.3) 17/8" (47.6) 11/16" (17.5) (7.07) (10.05) (12.10) (13.52) 131 (59.4) 980-3/4 51/4" (133.3) 17/8" (47.6) 13/16" (20.5) 130 (58.9) -Standard size. "Mounting attachment hole size. ""Installed with 1"or 11/4"Schedule 40 brace pipe. FM Approved design loads are based on ASD design method. Cooper B-Line,Inc.'s("Cooper B-Line")seismic bracingcomponents are designed to be compatible onlywith other Cooper B-Line P ( P P 9 P P bracing components, resulting in a listed seismic bracing assembly.Cooper-B-Line's warranty for seismic bracing components will be the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line,except that,in addition to the other exclusions from Cooper B-Line's warranty,Cooper B-line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. COUPffili B-Line Valves and Devices NiBC0 www.nibco.com AHEAD OF THE FLOW' Revision 4/20/2009 300 PSI WWP Bronze Ball Valves Dezincification Fire Protection Valve • Two-Piece Body • Chrome Plated Ball • Resistant Blowout-Proof Stem • Reinforced PTFE Seats 300 PSI/20.7 Bar Non-Shock Cold Water Fes., CONFORMS TO MSS SP-110 • UL LISTEDt • FM APPROVEDt MATERIAL LIST PART SPECIFICATION 1. Handle Nut Zinc Plated Steel KT-585-70-UL 2. Handle Zinc Plated Steel Clear Chromate 1/4"-1"Full Port with Plastisol Grip Threaded 3. Threaded Pack Gland Brass ASTM B 16 4. Packing PTFE KT-580-70-UL 5. Stem Silicon Bronze ASTM B 371 Alloy C69430 11/4'-3"Standard Port or ASTM B 99 Alloy C65100 Threaded 6. Thrust Washer Reinforced PTFE 7. Ball Brass ASTM B 124 Alloy C37700 or ASTM B 16 Alloy C36000 with Hard Chrome Plate C 8. Seat Ring(2) Reinforced PTFE 9. Body Cast Red Bronze ASTM B 584 Alloy C84400 0 10. Body End Piece Cast Red Bronze ASTM B 584 Alloy C84400 © �,/�� 1/4 and Vz size only has a 304 stainless steel grounding washer. as sy, o� B Q : ::i: *SOM 0 .444 `4-pew D 11) KT-585-70-UL Full Port DIMENSIONS-WEIGHTS-QUANTITIES NPTx NPT KT-585-70-UL Dimensions Size A B C D Port Weight Box Master KT-580-70-UL In. mm. In. mm. In. mm. In. mm. In. mm. Lbs. Kg. Qty. Ctn.Qty. Standard Port 1/48 2.00 51 1.75 44 5.00 127 38 10 45 20 10 100 NPT x NPT '/e 10 2.00 51 1.75 44 5.00 127 .38 10 45 .20 10 100 '/z 15 2.44 62 1.88 48 5.19 132 .50 13 .64 .29 10 100 3/4 20 2.94 75 2.25 57 6.25 159 .75 19 1.33 .60 5 50 1 25 3.34 85 2.38 59 6.44 164 1.00 25 1.79 .81 5 20 KT-580-70-UL Dimensions Size A B C D Port Weight Box Master In. mm. In. mm. In. mm. In. mm. In. mm. Lbs. Kg. Qty. Ctn.Qty. 11/4 32 3.94 100 2.63 67 6.75 171 1.00 25 2.17 .99 5 20 1' 40 4.31 110 3.00 76 8.91 228 1.25 32 3.27 1.49 5 20 2 50 4.63 117 3.25 83 9.06 230 1.50 38 5.09 2.31 5 10 21h 65 5.84 148 3.53 90 9.66 245 2.00 51 8.25 3.79 2 6 3 80 7.09 202 4.41 112 11.53 293 2.50 64 15.65 7.11 1 4 t UL Listed,FM Approved for trim and drain use-sizes V4"thru 2". APPROVED NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1 800 234 0227 TECH SERVICES PH:1.888.446.4226•FAX:1.888.336.4226•INTERNATIONAL OFFICE PH:+1.574.295.3327•FAX:+1 574.295.3455 111 IBC _ www.nibcc ccm AHEAD OF THE FLOW® Revision 4/20/2009 300 PSI WWP Bronze Ball Valves Dezincification Fire Protection Valve • Threaded or Grooved Body Style • Full Port Design 1" - 2" • Resistant Standard Port Design 21/2" ;, 300 PSI/20.7 Bar Non-Shock Cold Water ryy ' CONFORMS TO MSS SP-110 • FM APPROVED • UL LISTED FOR INDOOR AND OUTDOOR SERVICE • CALIFORNIA STATE FIRE MARSHAL LISTING NO. 7770-1243:103 APPROVED BY NEW YORK CITY M.E.A. 218-04-E WITH V :.- t •APPROPRIATE NYC INDICATOR. - KT-505-W-8 MATERIAL LIST ast, el CO Threaded PART SPECIFICATION 1. Body Bronze ASTM B 584 Alloy C84400 2. Ball Chrome Plated Brass ASTM B 124 Alloy C37700 3. Seat Ring Carbon-filled PTFE KG-505-W-8 4. Thrust Washer Reinforced PTFE Grooved 5. Stem Bronze ASTM B 371 Alloy C69430 n 6. Stem 0-Ring Nitrile 7. Retaining Washer Brass O if No 8. Retaining Ring Steel 0 O I IF4' i 9. Ground Wire Screw Steel o o i 0 10. 505-8 Act Assy. Brass '� 11. BodyEnd Bronze ASTM B 584 AlloyC84400 0 "y -fi.. •- 12. Mounting Screw Steel © tiriiii„:„Iiiit 13. Lock Washer Steel 0 IIII .IIII'II I 14. Handle Pin Brass 15. Hand Wheel Steel/plastisol coated(11/4"-21/2) -a - -- 'A"- - Brass Tee Handle(1'') 16. Indicator Flag Painted Steel - n 17. Body Gasket Elastomer 18. Lead Screw 0-Ring Nitrile - p d 19. Thrust Washer Anti-friction Polymer iL � �'4:ri 20. Cover Gasket Polychloroprene(CR) o itf0,,m5y 21. Flag Seal 0-Ring Nitrile - •i "Itilifi_ 141; 22. Tamper-Proof Screw Stainless Steel 23. Pipe Plug(-4 units) Stainless Steel(Not shown) - -I i G 00 Refer to page 42 for details for TS-2M Switch Kit. (Et KT-505W DIMENSIONS-WEIGHTS-QUANTITIES Dimensions _ A B Weight Size Threaded Grooved Threaded Grooved C 0 E F G Cvt Threaded Grooved Box Master In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. Value Lbs. Kg. Lbs. Kg.Oty. Ctn.Oty. 1 25 3.33 85 - - 1.66 42 - - 2.11 54 3.81 97 2.31 59 6.14 156 1.75 44 57 6.1 2.77 - - 1 10 11/4 32 4.18 106 - - 2.09 53 - - 2.46 62 4.21 107 2.72 69 6.33 161 3.50 89 103 7.1 3.23 - - 1 8 --♦ 11/2 40 4.70 119 - - 2.35 60 - - 2.95 74 4.46 113 2.97 75 6.33 161 3.50 89 143 8.1 3.68 - - 1 4 2 50 5.15 131 6.71 170 2.57 65 3.36 85 3.69 94 4.67 119 3.18 81 6.33 161 3.50 89 245 10.7 4.86 9.7 4.40 1 4 22 65 5.65 144 7.28 185 2.92 74 3.64 93 3.75 95 4.67 119 3.18 81 6.33 161 3.50 89 183 13.0 5.91 12.6 5.73 1 4 t Note:Cy is defined as the flow in GPM that a valve will carry with a pressure drop of 1.0 psi when the media is water at 60°F. 41* 0APPROVED IIINIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 TECH SERVICES PH:1 888446.4226•FAX:1.888.336.4226•INTERNATIONAL OFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 IBCD www.nibco.com AHEAD OF THE FLOW- Revised 7/25/2018 200 PSI WWP Bronze Check Valves Dezincification Fire Protection Valve • Horizontal Swing • Rubber Disc Resistant 200 PSI/13.8 Bar Non-Shock Cold Water CONFORMS TO MSS SP-80 MATERIAL LIST PART SPECIFICATION 1. Bonnet Bronze ASTM B62 or B584 Alloy C84400 164 2 Body Bronze ASTM B62 or B584 Alloy C84400 3. Hinge Pin Bronze ASTM B140 Alloy C31400 KT-403-W or B134 Alloy C23000 Threaded 4. Disc Hanger Bronze ASTM B62 5. Hanger Nut Bronze ASTM B97 Alloy C65500 or Brass ASTM B16 6. Disc Holder Bronze ASTM B62 7. Seat Disc Nitrite(W) PTFE(Y)# 8. Seat Disc Nut Brass ASTM B16 or B97 Alloy C65500 9. Hinge Pin Plug Bronze ASTM B140 Alloy C3200D �'t) (Not Shown) *10. Seat Disc Washer Stainless Steel h a h *Sizes 3/".1',11, and VA"only. g MMNp� �� Y 2'/z"and 3"size only. � (tr1 r _ *may tilt 514 o PIIIiNIIN �,.� INN�II� I�111111N -Illllyllu ri m i;�n! ��.�ll IIlll� DIMENSIONS-WEIGHTS-QUANTITIES Dimensions �" A Size A B Weight Box Master. KT-403-W In. mm. In. min. In. mm. Lbs. Kg. Qty. Ctn.Qty. NPT x NPT 1/2 15 2.44 62 1.69 43 .58 .26 10 50 1/4 20 2.94 75 1.88 48 .92 .42 10 50 1 25 3.56 90 2.31 59 1.55 .70 5 30 11 32 4.19 106 2.69 68 2.32 1.05 5 20 With 1/32" hole in 1'/2 40 4.50 114 2.94 75 3.00 1.36 2 10 clapper to accommodate 50 5.25 133 3.81 97 4.87 2.21 2 10 pressure fluctuations. 21/2 65 8.00 203 5.06 129 11.48 5.22 1 5 3 80 9.25 235 6.25 159 17.53 7.97 1 4 Sizes 21/2"and 3"supplied as T-433-Y with PTFE seat disc. NIBCO check valves may be installed in both horizontal and vertical lines with upward flow or in any intermediate position. WARNING-Valve must be installed downstream of receiver tank if used in line with reciprocating air compressor. eWARNING:This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm.For more information go to www.P65Warnings.ca.gov. Visit our website for the most current information. NIBCO INC.WORLD HEADQUARTERS•1515 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 14 TECH SERVICES PH:1.888.446.4226•FAX:1.888.336.4226•INTERNATIONAL OFFICE PH:+1.574.295.3327•FM:+1.574.295.3455 www.nibco.com 1 r. Antifreeze Solution APFIL.2021 freezem aster -j ANTIFREEZE DESCRIPTION Refer to the freezemaster—antifreeze Installation Lubrizol's freezemaster'°antifreeze is a non-toxic, premixed Guide for specific listings,approvals,directions antifreeze that is UL listed for use in wet fire sprinkler systems. and limitations. It has a freezing point of-15°F(-26.1°C), and is formulated for corrosionprotection in all pipingsystems including metalpipe Minimum Use Temperature:-12°F(-24.4°C) y Maximum Use Temperature: 150`F(65.6°C) and fittings.freezemaster'"antifreeze has been developed to meet stringent UL 2901 and NFPA 13,13R,13D and 25 fire NOTE:freezemaster'°antifreeze solution should only standards. be used in areas subject to freezing unless otherwise permitted by the authority having jurisdiction(AHJ). DESIGN APPLICATIONS Flow rates, pipe sizing,sprinkler spacing, hanging methods and system design must be in accordance with NFPA 13, 13R and 13D.freezemaster'"antifreeze is not listed for use in protecting extra hazard occupancies or flammable liquids, or use with ESFR sprinklers. SYSTEM LIMITATIONS Fire sprinkler systems utilizing freezemaster'°antifreeze shall meet the system size limitations as follows: Designation Use Temp Range Application Max Volume of Antifreeze in Sprinkler System Antifreeze -12°F to 150°F NFPA 13D('1 5500 gal;in accordance with NFPA 139 design criteria (-24°C to 66°C) NFPA 13R—Residential Only(including corridors, 5500 gal; in accordance with NFPA 13R design criteria garages that serve only a single dwelling unit,and compartmented Ordinary Hazard areas<500 sq ft)i'i Where NFPA 13 design criteria is required in areas Where NFPA 13R requires the use of NFPA 13 of an NFPA 13R Occupancy,such as an attic,use design criteria,refer to the NFPA 13 applications the applicable volume limitation for the hazard area and volume limitations. for NFPA 73. 5200 gal;in accordance with NFPA 13 design criteria or NFPA 13-Light Hazard Ill >200 gal to 5500 gal;in accordance with NFPA 13 using the dry system hydraulic design criteria,where the system hydraulics are designed as a dry system even though the system is filled with antifreeze. NFPA 13-Ordinary Hazard Groups 1 &2I'i <_40 gal;in accordance with NFPA 13 design criteria NFPA 13-Storagem 540 gal;in accordance with NFPA 13 design criteria [I]The antifreeze solution is intended to be installed in accordance with the manufacturer's instructions. For all systems,the following requirements shall apply:(a)the use of the antifreeze solution is limited to the aboveground system piping only except for a limited length of underground piping that connects sections of the aboveground system,(b)the viscosity of the antifreeze solution at the lowest anticipated temperature of the system shall be considered in the hydraulic design, (c)the friction loss shall be determined using the Hazen-Williams formula for water and the Darcy-Weisbach formula to account for the antifreeze solution fluid properties, 'and (d)the K-factor of the sprinkler shall be adjusted to account for the density of the antifreeze. s+ freezem aster •} ANTIFREEZE PACKAGING TYPICAL PROPERTIES WEIGHT PER U.S. GALLON APPEARANCE I 9.1 lbs(4.1 kg) Clear blue liquid • • PART NUMBER DESCRIPTION FREEZE POINT freezemaster"antifreeze -15°F(-26.1°C) FRZ27-PP5P -12°F 5-gallon pail fremaster'"antifreeze MINIMUM USE TEMPERATURE eez FRZ27-PTH55W eez -12°F(-24.4`C) 55-gallon drum FRZ27-T275R freezemaster'"antifreeze POUR POINT -12°F 275-gallon tote -22.4°F(-30.2°C) MAINTENANCE BURST POINT• -58°F(-50°C) freezemaster"antifreeze can remain in the system all year. NFPA 25 requires that antifreeze be tested annually. A portable DENSITY AT 77`F(25°C) hydrometer or refractometer can be used to see if the solution 1.085 g/cc has changed appreciably. REFRACTIVE INDEX AT 77°F(25°C) Store freezemaster"antifreeze indoors in a cool, dry place. 1.390 freezemaster"antifreeze is non-hazardous. Dispose SPECIFIC GRAVITY AT 77°F(25°C) accordingly per SDS instructions. 1.088 FLUID EXPANSION/CONTRACTION <5% FBe SYSTEM COMPATIBLE FBC System Gornpa4.'ole indicates that this product has been su tested,and is onpated it ongoing basand G ld o assure its chemical compatibility with FlowGuartl Gold". Lubrizol BlazeMaster°and Corzan'piping systems and products 120 made wth TempRite'Technology.The FBC System Compatible Logo,FBC`,FlowGuard Golo°,BlazeMaster`, Corzan".and TernpRite'are trademarks of Lubrizol CERTIFIED Advanced Materials,Inc.or its affiliates. snrrry ©2020 Lubnzol Adva•rced Materials,Inc. 20-0249050