Loading...
Permit ligCITY OF TIGARD MASTER PERMIT _ ' COMMUNITY DEVELOPMENT Permit#: MST2021-00228 Date Issued: 09/23/2021 ii I G A li D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 parcel: 2S107AA16400 Jurisdiction: Tigard Site address: 16571 SW TOWNSVILLE ST Subdivision: ROSHAK RIDGE Lot: 164 Project: Polygon at Roshak Ridge,Lot 164 Project Description: New detached dwelling BUILDING Floor Areas Required Setbacks Required Stories: 3 Bedrooms: 5 First: 1227 sf Basement: 763 sf Left: 3 Parking Spaces: 0 Height: 28 Bathrooms: 4 Second: 1726 of Garage: 486 sf Front: 8 Smoke Yes Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Total: 3716 Sf Value: 5481,626.36 Rear: 10 PLUMBING Sinks: 1 Water Closets: 4 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 6 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100 Tubs/Showers: 4 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Bckilw Prevntr: 0 Drywall-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 6 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Fum<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 7 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Y Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 3716 Owner: Contractor: POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions) 703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98660 VANCOUVER,WA 98660 2 One Hour Fire Rated Eaves PHONE: PHONE: 360-695-7700 FAX: Total Fees: $46,814.61 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 059-nM-nMn thrnnnh f1AR oc9-nn1-nnon Vrv,mm,nhfain=rnnv of fhn nilac nr dirar*nunefinne to ni intr.Mi Tallinn Snq 9's9 10R7 nr I AM'1'19 71dd Issued By: Ho61-Ad Va.w DI'Wege Permittee Signature: Ow Aptat.i4ctfizw, Call 503.639.4175 by 7:00 a.m.for the next available Inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each Inspection. . Building Permit Application 3—tp !'j f2 Residential RECEIVED FOR OFFICE USE ONLY �y� City of Tigard g 1�4J 4,-�' DataByy:d6,6 7 •e� i Permit No:4.S-20��-W228 4 13125 SW Hall Blvd.,Tigard,OR 97223 ryry ti Plan Review 1. 2' Phone: 503.718.2439 Fax 503.598.1960 J U N 0 9 LO 1.i Dete/By: C 3.0 24 J o Other Permi g_2C2jJ-a),61 T'1 G A R D Inspection Line: 503.639.4175 T Date Ready/By: t %. la See Page 2 for Internet: www.tigard-or.gov GI 1 1� OF' 1 iUh�i1✓ ed/Method: / 0 1 1 Supplemental Information TYPE OF WORK REQUIRED A:1-AND 2-FAMILY DWELLING ®New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ® 1-and 2-family dwelling ElCommercial/industrial Valuation: $ Li ` IUlt 3(41 0 Accessory building El Multi-familyNumber of bedrooms: 5 ❑Master builder 0 Other: Number of bathrooms: 4 JOB SITE INFORMATION AND LOCATION Total number of floors:3 W')- Job site address: 16571 SW Townsville Stree New dwelling area: 3,716 square feet (1` 1Q City/State/ZIP:Sherwood,OR 97140 Garage/carport area: 486 square feet I aD.1 Suite/bldg./apt.no.: Project namte:Polygon at Roshak Ridge Covered porch area: ...asquare feet `--Aa Cross street/directions to job site: Deck area: V i square feet ���..��t rrr��� Other structure area: y square feet REQUIRED DATA:COMMERCIAL-USE_ CHECKLIST Subdivision: Polygon at Roshak Ridge I Lot no.: 164 Permit fees'"are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. New residential construction- Total R3 Occupancy: 3,716 SF(SFU) Valuation: $ Elevation: 222803E-Projected Start: October 2021 Existing building area: square feet Deferrals:N/A New building area: square feet El PROPERTY OWNER ❑ TENANT Number of stories: Name:Polygon Homes WLH LLC Type of construction: Address:703 Broadway St.,Ste 510 Occupancy groups: City/State/ZIP:Vancouver,WA 98660 Existing: Phone:( 360 946 8674 Fax:( ) New: la APPLICANT 0 CONTACT PERSON 09 BUILDING PERMIT FEES' Business name:Polygon Homes WLH LLC (Please refer m fee schedule) Structural plan review fee(or deposit): Contact name:Omar Alami Abouhafs FLS plan review fee(if applicable): Address:703 Broadway St., Ste 510 Total fees due upon application: City/State/ZIP:Vancouver,WA 98660 Phone:(360) 695-7700 Fax::( ) Amount received: E-mail: Perm itsubmittals@taylormorrison.com I OAIamiAbouhafs@taylormorrison.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System. Business name:Polygon Homes WLH LLC Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:703 Broadway St., Ste 510 Solar Installation Specialty Code checklist. c;ty/state/zrP:Vancouver, WA 98660 Permit Fee(includes plan review $l80 00 and administrative fees): Phone:( 360)695-7700 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB tic.:207247 Total fee due upon application: $201.60 Authorized signature: ne1242.4."e ,, 6B This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name:Omar Alami Abouhafs Date: 06/07/2021 *Fee methodology set by Tri-County Building Industry Service Board. I:1Building\Permits1BUP-RESPermitApp_doc 02/24/2011 440-46I3T(11/02/COM/WEB) A • • Mechanical Permit Application FOR OFFICE USE ONLY a�•� Received e c7 r1 7 q City of Tigard {,.,�ECE�VE Pennft No.: M5T2.o2J-00 GAS 13125 SW Hall Blvd.,Tigard,OR 4722J l Plan Review Phone: 503.718.2439 Fax: 503.598.1960 palelBy_ Other Permit: T itil.ItI) Inspection Line: 503.639.4175 JUN 0 9 LU L Date Ready/By: O See Page 2 for Internet: www.ti rdor. ov 1um: 8a g Notified/Method: Supplemental Information CITY OF o IGAf J TYPE OF WO II-�ING�IVtS1ON COMMERCIAL FEE* SCHEDULE:— USE CHECKLIST Mechanical permit fees*are based on the value of the work el New construction 0 Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all 0 Demolition 0 Other: mechanical materials,equipment,tabor,overhead,and profit. Value:S CATEGORY_OF CONSTRUCTION RESTENTIAL EQUIPMENT(SYSTEMS FEES* ®1-and 2-family dwelling ❑Commercial/industrial 0 Aro'ssory building For special information use checklist 1 j Multi-family ❑ Master builder ❑Other. Description Qty. Ea. Total JOB SITE INFORMATION AND LOCATION Heating/cooling: Airconditioning I 46.75 Job site address: 16571 SW TOWNSVILLE ST Furnace 100,000 BTU(ducatvenu] 46.75 City/State/ZIP:Tigard,OR97224 Furnace 100,000+BTU(ducts/vents) 54.91 Suite/bldg./apt.no.: Project name: Polygon at Roshak Ridge Heat pump - 61.06 Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,snryv'nded etc. 46.75 Flue/vent for any of above 23.32 Subdivision: Polygon at Roshak Ridge I Lot no.: 164 Other. 23.32 Other fuel appliances: Tax map/parcel no.: Water beater 23.32 DESCRIPTION OF WOlUC Gas fireplace/insert 33.39 - New SFII type construction Flue vent for water heater or gas fireplace 23.32 Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 -Chimney/liner/flue/vent 23.32 ® PROPERTY OWNER 0 TENANT Other. 23.32 Environmental exhaust and ventilation: Name:Polygon WLH,LLC Range hood/other kitchen Address:703 Broadway St.,Ste.510 equipment 33.39 Clothes dryer exhaust 33.39 City/State/ZIP:Vancouver,WA 98660 Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:(360)695-7700 Fax:( ) Artic/crawlspace fans 23.32 ® APPLICANT 0 CONTACT PERSON Other: 23.32 Business name:Polygon WLH,LLC Fuel piping: S14.I5 for first four;S4.03 for each addition at Contact name:Tonja Morris Furnace,etc. Address:703 Broadway St.,Ste 510 Gas heat pump WaWsuspended/unit heater - City/State/ZIP:Vancouver,WA 98660 Water heater Phone:(360)695-7700 Fax::(360)693-4442 Fireplace E-mail:permitsubmittalsstaylormorDSOn.corn Range Barbecue CONTRACTOR Clothes dryer(gas) Business name:Pro Heating&Cooling Other: MECHANICAL PERMIT FEES' Address: NW Aloelek Dr,Ste.1104 Subtotal City/State/ZIP:Hillsboro,OR Minimum permit fee(S90.00) Phone:(360)270-1590 Fax:( ) Plan review(2S 6 of permit fee) State surcharge(12%of permit fee) CCB lic.:209001 TOTAL PERMIT FEE This permit application expires if a permit Is not obtained within 190 ®i days after it has been accepted as complete. Authorized signature: ' ' Fee methodology see by Tri-County Building Industry Service Board Print name:Elia Duran Date: 10/30/20 r.mnn6ins\Prrm.suc4tC P..me a..,rum ra A... •�n r�l+r..m+rrntsmmo. I Electrical Permit Application ` p FOR OFFICE USE ONLY City of Tigard ECEI V E '; ' Pgamtg. MI ST2021-00 z2s 1 41 13125 SW Ball Blvd.,Tigard,OR Plan Review I' Phone: 503.71.8.2439 Fax: 503.5913.1960 UardH • Related PermitX: Tla.\�U Inspection Line: 503.639.4175 ,��N ® " Z� ' ReadyDalr/ayr kris ®peePage2forormafion z Internet: wWw.Ggard-or.gov - ' Notified/Method. CITY OF illar'dli,s TYPE OF WOl�li nING bwi sin/, PLAN REYIEW - IN New construction ❑Addition/alteration/replacement Please check all that apply(submit j sets orphan writrros chocked) 0 Demolition ID Other: ❑Stxvioe or feeder 400 amps m more ElBuilding over three stones. suture the available fault current 0 Mantas tad bemoan& CATEGORY OF CONSTRUCTION ....coals 10,000 amps at 150 suIrs Of 0 Among beildmes 1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building lean to mound,er exceeds 14,000 Q Cummerei d_aso agricultural El Multi-familyLi Master builder El Other: amps for o he installations buildings. ❑Fitt pump.. 0 Itste1lllatatisw o(150 R:vA or JOB SITE 1NF01Rh1ATION Arch LOCATION t]Emergency system. larger separately derived CI Job#: Job site address:16571 SW TOWNSVILLE ST Additi°t°fae"m°t°`tpd°f y"ma 10911P m Marc. O"A",-E",-1-2"."1-3 City/State/ZIP: Tigard,OR 97140 ❑Six or tome residential malts oemmotty ❑healthcare facilities ❑Docreaatmd vehicle parks. Suite/bldg./apt.#: Project name: Polygon al Rosbalc Ridge 0 Hazardous buttons 0 Supply voltage for mere than 0 Service or fecdot 600 amps or more 600 volts nominal. Cross street/directions to job site: FEE SCIIEULII E' Description I SKY. I Each J Total I • New residential single-or multi-family dwelling malt, Subdivision:Polygon at Roshak Ridge Lot#: 164 Includes attached garage. Tax map/parcel#: 1,000 sq rt.or less 168 54 4 En.add'!500 sq.ft or portion 33.92 1 DESCRIPTION OF WORK Limited energy,residential 75.00 2 New construction.Type SFIJ (with above sq.tt) Limited energy.mtdti•family _ residcntml(with above Eq.ft) 75.00 2 ® PROPERTY OWNER ❑ 7F.l�AI�I Renewable Energy 0 Scr Page 2 Services or feeders installation,alteration,and/or relocation Name: Polygon Homes WLH LLC 200 amps ea less 190.70 2 Address: 703 Broadway St.,Ste 710 201 anon En 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/S tate/Z I P: Vancouver,WA 98660 601 amps to 1,000 amps 301.04 2 Phone:(360 )946 8674 Fax:( ) Ova 1,00o amps or volts 55226 2 Temporary services or feeders installation,alteration,and/or Snail: 0AlamiAbouhafs@taylormorrison.com-PermitSubmittals@tayIormomson.com relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 ' 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps ea400 _.� 125.08 2 Owner signature: _. Date: 401 amps to 599 amps 168.54 2 ❑ APPLICANT' I 0 CONTACT PERSON Branch circuits-new,alteration,or extension, ,er panel A.Fee for Manch circuits with Business name: Polygon Homes WI.H LLC above service or feoclm fee, 7 az each Contact name: Omar AlamiAbouhafa H.Fee for branch circuits wu wrthnarr service or feeder fox,first Address: 703 Broadway St.,Ste 710 branch circuit 56.18 2 City/State/ZIP:Vancouver,WA 98660 Eedr add'I blanch circuit 7.42 2 360946 8674Miscellaneous(service or feeder not included) Phone ( ) Fax::( ) Each manufactured or modular dwelling.service and/or feeder 67 84 2 Email:0AlamiAbouhafs@laylormorrison.com tlretrmeetrmty 6784 2 CONTRACTOR Pomp or irrigation circle 67.84 2 Business name: Wallace Electric Sign or outline lighting 67.84 2 Address: 105 Dresden St signal citeurt(s)or limited-energy ❑ See Page 2 2 moot alteration,or extension. . • City/State/ZIP: Astoria OR 97103 _Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 6625/br Phone:(503 308 0563 Fax:( ) investigation(I hr min) 90.00/hr Email: Davidt wal lacewires.com tndustr al plant(1 hr errs) 73.181 hr — inspections for which no fee is 90.00f hr CCB Lie.:224868 Electrical Li • C1441 Su v_I. .: 6363S specifically listed(14 hr min) ELECTRICAL PERMIT"FEES Suprv.Electrician signature,required: ..--- Subtotal Print name:'DJQti ap Date: et/6 Iz 1 0 Plan Review Requited(25%of permit fee): Iawe/ State surcharge(12%of permit fee):_ Authorized signature TOTAL PERMIT FEE: This permit application expires if a permit Is not obtained within 1811 Print name: �}1r. _ _ U Date: tip.�L f days aver It has beat accepted as complete. CJr • Number of inspections alloHcd per permit tatuthb i(Pamistl7.C_Permtapp,E1I)ERE.dx Ray 86/17/2015 4L4615RIVOSCOMAYEll Plumbing Permit Application Building Fixtures RECEIVE* FOR OFFICE USE ONLY City Tigard ofTi d Received IPermit No.:Gd m87-2(921-062 m 13125 SW Hall Blvd.,Tigard,OR 97223 j N N 0 9 202 y I Phone: 503.718.2439 Fax: 503.598.1960 PlanRe Review Date/Hy: Other Permit No.: T 1 c,t R D Inspection Line: 503.639.4175 CITY OF I I CARD Dec Rcady/By: Jwia: ® See Page 2 for Internet: www.tigardor.g)V BuII PIING DIVISION Notified/Method: Supplemental Information TYPE OF WORK FEE* SCHEDULE ®New construction ❑Demolition For speria/info tin a/ion use chec_klisr. Description I Qty. I Ea. I Total ❑Addition/alteration/replacement 0 Other: New 1-2-family dwellings(includes 100 ft.for each utility connection) CATEGORY OF CONSTRUCTION SFR(1)bath 312.70 Xl-and 2-family dwelling 0 Commercial/industrial SFR(2)bath 437.78 SFR(3)bath 500.32 ❑Accessory building Multi-family Each additional bath/kitchen 25.02 ❑Master builder 0 Other: Fire sprinkler( sq.ft.) Page 2 JOB SITE INFORMATION AND LOCATION Site utilities: Job site address: 16571 SW TOWNSVILLE ST Catch basin or area drain 18.76 City/State/ZIP:Tigard,OR 97224 Drywall.leach line,or trench drain 18.76 Footing drain(no.linear ft.:, ) Page 2 Suite/bldgdapt.no.: I Project name:Rasulan:Rrdgapolygon at Roshak Ridge Manufactured home utilities 50.03 Cross street/directions to job site: Manholes 18.76 Rain drain connector 18.76 Sanitary sewer(no.linear ft.: 1 Page 2 Storm sewer(no.linear ft.: ) Page 2 Water service(no.linear ft.: 1 Page 2 Subdivision:I Polygon at Roshak Ridge I Lot no.: 164 Fixture or item: Tax map/parcel no.: Bacldlow preventer - 31.27 DESCRIPTION OF WORK Backwater valve 12.51 Clothes washer 25.02 New SFU type construction Dishwasher 25.02 Drinking fountain 25.02 Ejectors/sump 25.02 ® PROPERTY OWNER I 0 TENANT Expansion tank 12.51 Name:Polygon WLH,LLC Fixture/sewer cap 25.02 Floor drain/floor sink/hub 25.02 Address:703 Broadway St.,Ste 510 Garbage disposal 25.02 City/State/ZIP:Vancouver,WA 98660 Hose bib 25.02 Phone:(360)695-7700 Fax:( ) Ice maker 12.51 ® APPLICANT ❑ CONTACT PERSON Interceptorigrease trap 25.02 1 Business name:Polygon WLH,LLC Medical gas(value:$_) Page 2 Primer 12.51 Contact name:Tonja Morris Roof drain(commercial) 12.51 Address:703 Broadway St.,Ste 510 Sink/basin/lavatory 25.02 City/State/ZIP:Vancouver,WA 98660 Solar units(potable water) 62.54 Phone:(360)695-7700 Fax::(360)693-4442 Tub/shower/shower pan 12.51 Urinal E-mail:permItsubmittals@polygonhomes.com 25.02 CONTRACTOR Water closet 25.02 Water heater 37.52 Business name:G&B Plumbing&Sons Inc Water piping/DWV 56.29 Address:P.O.Boa 92 Other. 25.02 City/State/ZIP:St.Paul,OR 97137 Subtotal Phone:(503)868-1417 Fax:(971)727-8170 Minimum permit fee: S72.50 CCB Lic.:184372 Plumbing Lic.no.:pb634 Plan review (25%of permit fee) l State surcharge(12%of permit fee) Authorized signature: , 1 < z TOTAL PERMIT FEE Print name:Steve Fowler Date: 0/30/20 This permit application expires If a permit Is not obtained within 180 days after it has been accepted as complete. `Fee methodology set by Tri-County Building Industry Service Board. I:‘Buildiag`.PermitsfPLMU-PermitApp.doc 10/01/09 440-4616T(re"MJCOM'WEB) Plan # 28a3E rz r- \ C,,,Liz-i V Floors 7J �r � Large 'Lc Bed rooms J Small lP WC 14 LAV Ly Tub Basement 7(- 3 Vent Gp 1st Floor aa7 Water Heate1 2nd Floor 1'—ja(e AC n 3rd Floor School � .o-v---e0 R-3 Total 31 D k._ 12ce, Garage 4/84 Total l{ 00.... #for Elec City of Tigard • Illi . COMMUNITY DEVELOPMENT DEPARTMENT T l G n :D Building Permit Review — Residential Building Permit #: MS ( 2O2 H-0012 Site Address: 16571 SW Townsville St Project Name: Polygon at Roshak Ridge Lot #: /(4 Planning Review P posal: New single detached house Verify address/suite #active in Accela. LU�/In River Terr e: ❑ No ✓Yes, River Terrace Review Addendum Si'- Plan Elements: E� .: .n Control a •opies of site plan on 8-1/2"x 11"or 11 x 17"paper k�r At.' ed trees with drip line and tree protection measures J. ewn to scale(standard architect or engineer scale) !!ootprint of new structure(including decks) and FFE Jt4• h arrow J, '.'ty locations&easements(required for new and additions) U. to address,project or subdivision name and lot number S.id- . alk/driveway approach K, .plicant information(name and phone number) Il''s cation of wells/septic systems WI •t dimensions and building setback dimensions PI eet tree size,type and location 11 Il.quare footage of buildings to be demolished PI. -et names II xisting structures on site 7 orner elevations(2'contours if more than 4'diffe ntial II t area,building coverage area,percentage of coverage and >1,000 sf of impervious area created or replaced? es It • impervious area (applicable if R-7,R-12,R-25&R-40) ' If yes,is a storm water quality facility shown? es o ❑ Clean Water Services —Service Provider Letter (lot platted prior to 9/10/1995): Required: ❑Yes,applicant was notified El No Received: ❑ Yes ❑ No Water Meter Fixture Unit Worksheet—Additions,Remodels and ADUs ��\,1-1 uired: ❑Yes,applicant was notified CI No,, , Received: ❑Yes ❑ No DC Exemptio for ADU applied for: Yes ❑No Received: El Ye El No Public Facilt Improvement (PFI) Permit: equired: Yes,applicant was notified ❑ No nd Use Case#: SUB2015-00004 pplied For: Yes ❑ No,stop intake Zoning: R-4.5 equired Setbacks: Front: 8 Rear: 10 Side: 3 Street Side: 8 Garage: 20 Building Height: Max.Height: N/A Actual Height: . -. cape Area: % ❑ Lot Coverage : Entrance sack no more than 8'from street-facing wall 1 Parallel , eet or offset 45 degrees or less Windows Minimum —' of area of all street-facing facades\� Garage Gara e door is behin. ...:- t street-facing wall Yes ElNo,one of the following is met: ❑gDoor extends no more than ...: . all and there is a covered porch extending beyond garage. uuDoor extends no m_o - . .n 5'from wa I . ere is a 12 sq ft.window above garage on 2°d floor. ❑ Gar.:e door '. 12'or less ❑ 50°/u or less o : ...c 60%or less and includes 7 of following: . ered porch Recessed entrance ❑ Wall offset ' t oof eave Roof offset Fire shingles Lap Siding ❑ Roof itch ❑ Gable, ,or g. - . - roof Dormer Accent siding Window trim li Window recess U Window projection I Balcony V' ual Clearance X Urban Pores W:-nsitive Lands: ❑ Yes No Type: PI Co itions met prior to issuance of building permit No s: ! Approved By Planning: Date: /9h/ Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved I:\Building\Forms\BldgPerm itRvw_RES_122419.docx Building Permit Submittal Original Submittal Date: QG/o 9/icii • Site Plans: # 3 Building Plans: # 3 Building Permit#: a� Enter building permit#above. n� Workflow Routing: Planning ,� Engineering Permit Coordinator Building Workflow Sign-off: Sign-off for Planning(include notes from planning review) Route Application Documents: Q'Engineering: (1) copy of permit application, (1) site plan, (1) building plan and original plan review routing form. n' ISM Building: original permit application, site plans, building plans, engineer and beam calculations and s. details,if applicable,etc. Notes: By Permit Technician: Date: at/16/LC1L/ Engineering Review �E Slope at building pad: (3 ,3 N I Conditions "Met"prior to issuance of building permit a-Easements (encroachments) per engineering conditions of approval and plat Water Quality/Quantity Facility: Assess Water Quality Fee in-lieu: ❑ Yes RNo Assess Water Quantity Fee in-lieu: ElYes In No LIDA Facility on lot: ❑ Yes Ro ❑ Final Plat Recorded: ❑ NOT Approved by Engineering: Date: Notes: Approved by Engineering: A42-4<t›./ Date: 6/ti/e.z)2./ Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved ermit Coordinator Review C. ditions "Met"prior to issuance of building permit pproved, NOT Released: Date: Notes: Revisions (after Building Submittal only) Revision Notice 1: Date Sent to Applicant: Re .sion Notice 2: Date Sent to Applicant: L ❑ RecJ 10C Exemption:', eived Does not a5 ly SDC Fees Entered: Wash Co Trans Dev Tax: s I N/A Tigard Trans SDC: es ❑ N/A i ! Parks SDC: Yes ❑ K/A LIDA ❑ Yes N/A U OK to Issue Permit Approved by Permit Coordinator: ��'="`_ •---�- Date: 1:\B ui I di n g\Forms\B I d gPe miitRvw_RES_122419.do cx City of Tigard NI COMMUNITY DEVELOPMENT DEPARTMENT e River Terrace Building Permit Review Addendum TIGARD Building Permit #: M STZ02-I-00 22B Site Address: 16571 SW Townsville St Project Name: Polygon at Roshak Ridge Lot #: 164 (New dwelling=subdivision name;Addition or Alteration=last name of owner) Planning Review of River Terrace Plan District Design Standards (18.640.070.1): Is the project subject to the plan district design standards? ❑Yes ❑No 1.Articulation: a minimum of 1 element per each street-facing facade that has 30-60 ft. of frontage.An additional element required for lots with over 60 ft. of street frontage shall be provided every 30 ft. Balcony w/ access 2 Window Projection Vertical Wall Offset a Porch min. ft. deep ft. deep❑ min. 2ft., 5 ft.wide ❑ min. 2 ft., 6ft.wide ❑ Gabled dorm r G 2. Eyes on tithe street: a minimum of 12%of each street facing facade must include windows or entrance doors. Percentage Shown: >/2°/n 3.Intrances: At least one entrance must /meet both of the foll wing standards: Max. 8 ft. setback from lost street- facing wall Parallel to street,angle no more than 45° from street, or o en onto porch En ante opens to a porch: Yes ❑No e ,all the following apply: �5 sq.ft.min. Ifne street facing entry Vft. max.roof above floor of porch 5 ft. depth min. 30%min. porch roof coverage 4. etailed Design: All buildings shall indude n. of five of th following elements on all street-facing facades: ®Covered porch min. 5 ft.wide x 5 ft. deep' ❑ cessed entry area min. 5 ft.wide x 2 ft. deep ❑yll offset min. 16 inches ®Dormer min. 4 ft.wide Ro eof cave min. 12 inch projection of offset min.of 2 ft. ` Roof shingles either tile or wood Gable,hip or gambrel roof design Voof pitch oriented south min. 500 sq. ft. ❑ zontal lap siding min. 3-7 inches wide ccent siding min. 40% of street facade indow trim min. 2 1/2'wide by 5/8" deep ❑Window recess min. 3 inches for all street facing ❑Bay window min. 5 ft.wide by 2 ft. deep ❑Balcony min. 5 ft.wide x 3 ft. deep with inside access ❑Attached garage is 35% or less of street facade 5. Garages and Carports: May face the front or side lot line on a co r lot. Setbacks: No closer to front or side lot line,than longest street-facing wall. Yes ❑No. If No (Check one): ❑May extend up to 5 ft.if there is a covered front porch and garage does not extend beyond the front porch. ❑May extend up to 5 ft.where the garage is part of a two-story building and there is a window at the second story above the garage that faces the street with a min. area of 12 sq.ft. Width: (Check one) ❑12-foot-wide garage door 40%max. of street facade ❑50% max. of street facade with 7 detailed design elements Notes: Approved By Planning: — Date: I:1Bui Iding\Forms\BldgPermitRvw_RES_RT_121417.docx