Loading...
Report -Feszczt-CoMI OFFICE COPY ►34OSui Qbfic.RECEIVED Page 1 of 7 NIKING MI SDARD AND TECHNICAL DATA Q PENDENT SPf�1 -E 62 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. DESCRIPTION Viking Mirage® Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. ' 7 The sprinkler is pre-assembled with a threaded adapter for installation with a low- profile cover assembly that provides up to '/z (12.7 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of £ the cover plate. The The "push-on° and "thread-on" designs of the concealed cover plate assemblies allow easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed • and reinstalled,allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive environments and is listed and approved as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly,the cover plate is not plated. 2. LISTINGS AND APPROVALSJam CON cULus Listed: Category VNIV -<> FM Approval: Class 2015 NYC Approved: MEA 89-92-E,Volume 32 WARNING Cancer and Reproductive Harm- VdS / \ www.P65Warnings.ca.gov VdS Approved: Certificate G4080021 "`B LPCB Approved: Ref. No. 096e/12 C E CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032 China Approval:Approved according to China GB Standard Refer to the Approval Charts and Design Criteria listing and approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: 7 psi (0.5 bar)" Maximum Working Pressure: Sprinkler VK463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating "250" stamped on the deflector. Sprinkler VK462 is rated to a maximum 175 psi (12 bar)wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2° (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metric—) Glass-bulb fluid temperature rated to-65°F (-55°C) Patents Pending cULus Listing,FM Approval,and NFPA 13 installs require a minimum of 7 psi(0.5 bar).The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi(0.35 bar). "Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UNS-C19500 for Sprinkler; Phosphor Bronze UNS-051000 for Sprinkler VK463 Deflector Pins: Stainless Steel Alloy Bulb: Glass, nominal 3 mm diameter Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Yoke: Phosphor Bronze UNS-051000 Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Cover Assembly Materials: Cover: Copper UNS-C11000 or Stainless Steel UNS-S30400 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: The sprinkler and cover plate must be ordered separately. Refer to Tables 1 and 2. Form No. F 103005 20.06.26 Rev 20.3 Replaces Form No. F_103005 Rev 20.2 (Added cover plate options.) Page 2 of 7 NIKING„.„ MIRAGE® STANDARD AND TECHNICAL DATA SPRINKLER VK462 A DENT HP SPRINKLER VK463 (K5.6) The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions,when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection,Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: SPRINKLER ORDERING INFORMATION Instructions: (1) Select a Sprinkler Base Part Number (2)Add the suffix for the desired Finish (3)Add the suffix for the desired Sprinkler Temperature Rating (4) Order a cover plate (refer to Table 2) Example: 13503AE=200°F (93 °C)Temperature Rated Sprinkler with a standard Brass finish. Sprinkler Size 1: Finishes 2:Temperature Ratings SIN Base Part NPTSprinkler Max.Ambient Number° InchBmmT Description Suffix' Temperature Nominal Rating Bulb Color Ceiling Suffix Classification Temperature2 VK462 13503 1/2 -- Brass A Ordinary 155 °F (68 °C) Red 100 °F (38 °C) B VK462 2135679 — 15 ENT 34 JN Intermediate 175 °F (79°C) Yellow 150 °F (65 °C) D VK463 13667 1/2 -- Intermediate 200 °F (93 °C) Green 150 °F (65 °C) E Accessories Sprinkler Wrenches and tools (see Figure 1): A. Heavy Duty Part Number: 14047WB5 (available since 2006) B. Head Cabinet Wrench Part Number: 14031' (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part Number: 1441270 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 14867t0(available since 2007) Sprinkler Cabinet: Holds up to 6 sprinklers: Part number 01731A(available since 1971). Footnotes 1. Where a dash(-)is shown in the Finish suffix designation,insert the desired Temperature Rating suffix.See example above. L Based on NFPA 13,NFPA 13R,and NFPA 13D. Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction.Refer to specific installation standards. 3. UL Listed as corrosion resistant. 4. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart.These tests cannot and do not represent all possible corrosive environments.Prior to installation,verify through the end-user that the coatings are compatible with or suitable for the proposed environment.For automatic sprinklers,the ENT coating is applied to all exposed exterior surfaces,Including the waterway. 5. Requires a Y2"ratchet(not available from Viking). 6. Also optional for removal of the protective cap.Ideal for sprinkler cabinets. 7. Not available with ENT finish.See approval charts for more information. °. See approval charts for more information. a Approved according to China GB Standard. +°.The installer tool is for push-on style cover plates only. Form No. F 103005 20.06.26 Rev 20.3 Page 3of7 NIKING® MIRAGE® STANDARD AND QR CONCEALED PENDENT TECHNICAL DATA SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945.9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com TABLE 2: COVER PLATE ORDERING INFORMATION Instructions: (1)Select a Cover Plate Base Part Number (2)Add the suffix for the desired Finish (3)Add the suffix for the required Cover Plate Nominal Rating. Example: 23190MC/W=165"F (74°C)Temperature Rated,2-3/4"(70 mm)diameter,Thread-On style Round Cover Plate with a Painted White finish. 1: Select a Cover Plate Base Part Number' 2: Select a Finish Thread-On Style Push-On Style Base Part Size Type Base Part Size Type Description Sufflx5 Number Inch(mm) Number Inch(mm) 23190 2-3/4 (70) Round 23447 2-3/4 (70) Round Polished Chrome F 23174 3-5/16 (84) Round 23463 3-5/16 (84) Round Brushed Chrome F-/B 23179 3-5/16 (84) Square 23482 3-5/16 (84) Square Bright Brass B StaStainless Antique Brass B-/A 231934 2-3/4 (70) Steel Round 23455nless4 2-3/4 (70) Steel Round Brushed Brass B-/B Stainless Stainless Brushed Copper E-B 231834 3-5/16 (84) Steel Round 234734 3-5/16 (84) Steel Round Painted White M /W 23174-/CR 3-5/16 (84) Clean Room 23463-/CR 3-5/16 (84) Clean Room Painted Ivory M-/I Stainless Stainless Painted Black M-/B 23183CR4 3-5/16 (84) Steel Round 23473CR4 3-5/16 (84) Steel Round Clean Room Clean Room 3:Temperature Rating Matrix1'2 Cover Plate Nominal Temperature Sprinkler Maximum Ambient Suffix Rating (Required) Classification Sprinkler Nominal Rating Ceiling Temperature2 UL: 135 °F (57 °C) Ordinary 155 °F (68 °C) 100 °F (38 °C) A FM: 139° F (59 °C) 165 °F (74 °C) Intermediate 175 °F (79 °C) 150 °F (65 °C) C 165°F (74 °C) Intermediate 200 °F (93 °C) 150 °F (65 °C) C Footnotes 1. The sprinkler temperature rating is stamped on the deflector. 2. Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction.Refer to specific installation standards. 3. Part number shown is the base part number.For complete part number,refer to current Viking price list schedule. 4. Stainless Steel versions are not available with any finishes or paint. 5. Where a dash(-)is shown in the Finish suffix designation,insert the desired Temperature Rating suffix.See example above. Form No. F_103005 20.06.26 Rev 20.3 Page 4 of 7 II(JF'lG ® MIRAGE® STANDARD AND OR CONCEALED PEND TECHNICAL DATA SPRINKLER VK462 A DENT HP SPRINKLER VK463 (K5.6) The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart 1 (UL) j CCo eMq ate Temperature e ng Mirage"'Concealed Pendent Sprinklers VK462 and VK463 AW14-Covet Plate Finish KEY Listings and Approvals' Sprinkler Thread Size Nominal K-factor Maximum (Refer also to Design Criteria) Base Part SIN Water Working China No.' NPT BSPT U.S. meiric2 Pressure cULus6 NYC VdS7 LPCB CE Approval Inch mm Standard Response Applications 13503A VK462 1/2" -- 5.6 80.6 175 psi(12 bar) — -- AY1,CZ1 AY1, BZ1 AY1,CZ1' — 21356A1' VK462 -- 15 5.6 80.6 175 psi(12 bar) -- -- — -- -- All,CZ1 Quick Response Applications 13503A VK462 1/2" 15 5.6 80.6 175 psi(12 bar) AV1,BX1,AS2,BT2 AV1,BX16 — — -- -- 13503JN" VK462 1/2" 15 5.6 80.6 175 psi(12 bar) AV1,BX1,AS2,BT2 AV1,BX16 — — -- -- 21356Al2 VK462 — 15 5.6 80.6 175 psi(12 bar) AY1,CZ1 - — — — — 13667A VK463 1/2" 15 5.6 80.6 250 psi(17.2 bar)' AV1,BX1 AV1,BX16 — -- -- — 13667JN" VK463 1/2" 15 5.6 80.6 250 psi(17.2 bar)' AV1, BX1 AV1,BX16 — -- -- — Approved Sprinkler Approved Cover Plate Temperature Rating Codes Approved Cover Plate Finish Codes Temperature Rating Codes S-135°F(57°C)cover 23193,23445 or 23183,23473(large diameter) T-165°F(74°C)cover 23193,23445 or 23183,23473(large diameter) 1 -Polished Chrome,Brushed Chrome, A=155°F(68°C) V- 135 °F (57 °C) cover 23190, 23447, 23174, 23463 (large diameter), or Bright Brass,Antique Brass,Brushed B=175°F(79°C) 23179,23482(square cover plate) Brass,Brushed Copper,Painted White, C=200°F(93°C) X-165°F(74°C)cover 23190,23447,or 23174,23463(large diameter) Painted Ivory,or Painted Black Y-135°F(57°C)cover 23190,23447 LPCB Approved as 139°F(59°C) 2-Stainless Steel Z-165°F(74°C)cover 23190,23447 Footnotes 1. Part number shown is the base part number.For complete part number,refer to current Viking price list schedule. 2. Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 2. The Water Working Pressure rating is stamped on the deflector. e. This chart shows the listings and approvals available at the time of printing.Other approvals may be in process.Check with the manufacturer for any additional approvals. s. Listed by Underwriter's Laboratories for use in the U.S.and Canada. e. Accepted for use,City of New York Department of Buildings,MEA Number 89-92-E,Vol.32. 7. VdS Approved,standards VdS 2344:2005-12,VdS 2100.25:2008-01,and EN 12259-1:1999+A1:2001 +A2:2004+A3:2006,Certificate G4080021. a. CE Certified,Standard EN 12259-1,EC-certificate of conformity 0832-CPD-2032. s. The 135/139°F cover has an orange label.The 165°F(74°C)cover has a white label. 1 s.Painted finish consists of Polyester Baked Enamel.Other paint colors are available on request with the same listings as the standard paint colors.Listings and approvals apply for any paint manufacturer.Contact Viking for additional information. ".cULus Listed as corrosion resistant. 12.Approved according to China GB Standard. NOTE:Custom colors are indicated on a label Inside the cover assembly.Refer to Figure 1. Form No. F_103005 20.06.26 Rev 20.3 • Page 5 of 7 NIIKING® MIRAGE® STANDARD AND TECHNICAL DATA SPRINKLER VK462 ANDENT HP SPRINKLER VK463 (K5.6) The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESIGN CRITERIA- UL (Also refer to Approval Chart 1) cULus Listing Reauirements• Mirages Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. • For hazard occupancies up to and including Ordinary Hazard,Group II. • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13.Maximum spacing allowed is 15 ft.(4.6 m). • Minimum spacing allowed is 6 ft.(1.8 m)unless baffles are installed in accordance with NFPA 13. • Minimum distance from walls is 4 in.(102 mm). • Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. • The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. VdS Approval Reauirements: a)The sprinkler can be installed in a concrete ceiling(massive ceiling)or in a false ceiling made of light materials. b)This sprinkler is deflector fixed type and can be only activated by heat.The housing is not tight. c)Follow installation guidelines of current standards, CEA4001VdS and EN12845.These sprinklers can only be installed in LH and OH occupan- cies,except in OH4. NOTES: Due to the design the sprinkler type Domed-CCP'shall not be installed in false ceilings in which the false ceiling space is protected by a water extinguishing system. Due to the design the sprinkler type'Domed-CCP'shall not be installed in false ceilings in which during a fire the pressure above the false ceiling may be assumed to be higher than the pressure below the false ceiling. The criterion for the dropping of the cover relevant for this approval is heat. Steps of installation: 1. Prepare the sprinkler key. 2. Remove the plastic cover. 3. Hold the sprinkler with the wrench and fasten it. 4. Replace the plastic cover and do not remove until the cover is installed. IMPORTANT: Always refer to Bulletin Form No. F 091699-Care and Handling of Sprinklers.Also refer to Form No. F080614 the general care, installation,and maintenance information.Viking sprinklers are to be installed in accordance with latest edition of Viking technical data, the appropriate standards of NFPA, LPCB,APSAD, VdS or other similar organizations, and also with the provisions of governmental codes,ordinances, and standards,whenever applicable. CUS , v\�p TOM QQ ,4) All custom color painted cover �Q 9� plates will have an identifying O label affixed to the inside of the cover that indicates the U custom color and will have a representative sample(a paint dot)of the paint on the label. Figure 1: Identification of Custom Paint for Concealed Covers Figure 2: Square Cover Assembly Form No. F 103005 20.06.26 Rev 20.3 Page 6of7 NIKING0 MIRAGE® STANDARD AND TECHNICAL DATA QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart 2 (FM) ,F-Co nka to Temperature Rating j Dover Rate Temperature Rating Miragee Standard Response Concealed Pendent Sprinkler VK462 AM*coder Plate Final) KEY Thread Size Nominal K-Factor Maximum FM Approvals' Sprinkler Base SIN Water Working Part No.' NPT BSPT Pressure Inch mm (Refer also to Design Criteria below.) U.S. metric' 13503A VK462 1/2" 15 5.6 80.6 175 psi(12 bar) AW1,BX1,AY2,BZ2 21356A' VK462 — 15 5.6 80.6 175 psi(12 bar) AU1,CV1 Approved Sprinkler Temperature Approved Cover Plate Temperature Rating Codes Approved Cover Plate Finish Codes Rating Codes U-139°F (59°C)cover 23190, 23447 V- 165°F(74°C)cover 23190,23447 W-139°F(59°C)cover 23190,23447,or 23174,23463 1 - Polished Chrome, Brushed Chrome, Bright A-155°F(68°C) (large diameter),or 23179,23482(square cover plate) Brass, Antique Brass, Brushed Brass, B-175°F(79°C)and 200°F(93°C) X- 165°F (74°C)cover 23190, 23447,23174, 23463 Brushed Copper, Painted White, Painted C-200°F(93°C) (large diameter),or 23179,23482(square cover plate) Ivory, or Painted Black Y-139°F (59°C)cover,23183,23473 or 23193,23455 2-Stainless Steel Z-165°F (74°C)cover 23183, 23473 or 23193, 23455 Footnotes 1. Part number shown is the base part number.For complete part number,refer to current Viking price list schedule. z Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 3. This chart shows the FM Approvals available at the time of printing.Other approvals may be In process.Check with the manufacturer for any additional approvals. 4. The 139°F(59°C)cover has an orange label.The 165°F(74°C)cover has a white label. 5. Painted finish consists of Polyester Baked Enamel.Other paint colors are available on request with the same listings as the standard paint colors.Listings and approvals apply for any paint manufacturer.Contact Viking for additional information. a. Approved according to China GB Standard. NOTE:Custom colors are indicated on a label inside the cover assembly.Refer to Figure 1. DESIGN CRITERIA-FM (Also refer to Approval Chart 2 above.) FM Approval Reauirements: Viking Concealed Pendent Sprinkler VK462 is FM Approved as a standard response Non-Storage concealed pendent sprinkler as indicated in the FM Approval Guide.For specific application and installation requirements,reference the latest applicable FM Loss Prevention Data Sheets(including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design,ceiling slope and obstructions, minimum and maximum allowable spacing,and deflector distance below the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT:Always refer to Bulletin Form No. F_091699-Care and Handling of Sprinklers.Also refer to Form No. F_080614 for general care, installation,and maintenance information.Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data,the appropriate standards of NFPA, FM Global, LPCB,APSAD,VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards,whenever applicable. Form No. F_103005 20.06.26 Rev 20.3 Page 7 of 7 NIKING4 ® MIRAGE® STANDARD AND TECHNICAL DATA QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Sprinkler and 2-1/4" (57 mm) Adapter Assembly —.- ' diameter opening • Protective cap Sprinkler Wrench required in the removed ) Part No. 14047W/B** - ceiling. • Use wrench 14047W/B** 4 t .�� t Step 1: Step 2: t Carefully slide the Carefully press the wrench upward and wrench sideways around turn slightly to ensure engagement with the deflector and pins the sprinkler wrench flats. NEVER install the sprinkler by applying the installation Sprinkler wrench across the frame arms. DO NOT overtighten. wrench fla —" Use only the designated sprinkler wrenches, Viking t Sprinkler Part Numbers 14047W/B**or 14031**.A leak tight seal (s frame arms should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. Figure 3: Sprinkler Installation and Proper Wrench Usage t,. ** A 1/2"ratchet is required(Not available from Viking) i 1/2" (15 mm) NPT 2-9/16" (65 mm) , Maximum 2-1/16" (52 mm) Minimum li --•—.... eC—e— io E t• M . . - ,r 1 -.. f T MEN . _„„4. ac. i °ill I.* 2-3/4" (70 mm) or ►1 NOTE: Upon sprinkler activation, the deflector descends 3-5/16" (84 mm) to approximately 13/16"(21 mm)below the sprinkler body. Figure 4: Sprinkler Dimensions and Cover Installation Form No. F_103005 20.06.26 Rev 20.3 Replaces Form No. F_i 03005 Rev 20.2 (Added cover plate options.) RECEIVED Page 1 of 6 NIIKING 8 IfdlO FAS! QUICK TECHNICAL DATA RESPOWIRENDENT SPRINKLER VK302 (K5.6) The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page:www.vikinggroupinc.com 1. DESCRIPTION The Viking Microfast® Quick Response Pendent Sprinkler VK302 is a small thermosensitive glass bulb spray sprinkler available with various finishes and tern- perature ratings to meet design requirements.The special Polyester and Electroless Nickel PTFE (ENT)coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive environments and are Listed and Approved as indicated in the Approval Charts. 2. LISTINGS AND APPROVALS c qL as cULus Listed: Category VNIV FM Approved: Class Series 2000 ^\ Harm Cancer and Reproductive vdsJ VdS Approved: Certificates G414009, G414010, G4040095, and 4880045 / mon Peswammgs.ce.gov tPs; LPCB Approved: Certificate 096e/06 C E CE:Standard EN 12259-1,Dedaration of Performance DOP_Sprinklers_LPCB_5-2-19,DOP_VK302ENT_29-1-20&DOP_VK302- 57C_30-9-20 China Approval:Approved according to China GB standard . MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar)water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to-65°F (-55 °C) Overall Length: 2-1/4" (58 mm) *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap- ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Form No. F_033314 20.07.14 Rev 20.1 Replaces Form No. F_033314 Rev 19.3 (Added ENT to CE Approval.) Page 2of6 II(jF1 ® MICROFAST® QUICK TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page:www.vikinggroupinc.com Finish Suffix: Brass=A, Chrome = F, White Polyester= M-/W, Black Polyester= M-/B, and ENT=JN Temperature Suffix: 135°F (57 °C)=A, 155°F (68 °C) = B, 175 °F (79 °C)= D, 200 °F (93 °C)= E, 286 °F (141 °C) = G For example, sprinkler VK302 with a Brass finish and a 155 °F (68 °C)temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Sprinkler Wrenches: A. Standard Wrench: Part No. 21475M/B. B. Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A'/,"ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1"diameter CPVC tubing to the tool. Ideal for sprinkler cabinets.Refer to Bulletin F_051808. Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A(available since 1971) B.Twelve-head capacity: Part No. 01725A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection,Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfaste Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flat Protective Sprinkler Cap t} 21475 1 Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F_033314 20.07.14 Rev 20.1 Page 3 of 6 NI KING® MICROFAST5 QUICK TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page:www.vikinggroupinc.com TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature' Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175°F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings': White Polyester, and Black Polyester. ENT in all temperature ratings except 135 °F (57 °C) Footnotes 'The sprinkler temperature rating is stamped on the deflector. 3 Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 'The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts.These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers,the coatings indicated are applied to the exposed exterior surfaces only.Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers,the waterway is coated. r .. a, r. .�• y .- . :`.fix. ar•-.� _, Sprinkler wrench 13655W/B** for recessed pendent sprinklers --A 112" ratchet is required (not available from Viking) -411111 — Carefully slide the wrench sideways around �� the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No. F 033314 20.07.14 Rev 20.1 Page 4of6 NIKING® MICROFAST® QUICK TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945.9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page:www.vikinggroupinc.com Approval Chart 1 (UL) Temperature KEY The Viking Mlcrofaste,Quick Response � Finish Pendent Sprinkler VK302 A124-Escutcheon(if applicable) Maximum 175 PSI(12 Bar)WWP Thread Size Nominal Overall Listings and Approvals' Base Sprinkler K-Factor Length (Refer also to Design Criteria.) Part SIN Style Number' NPT BSP U.S. metric' Inches mm cULus` VdS LPCB CE' MED° China Approval 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 AIZ,B1Y,D2,C2X Al A1Z,B1Y D1Z,C1Y,D2, D1 — A1Z,B1Y 213546 VK302 Pendent -- 15 mm 5.6 80.6 2-1/4 58 D3 -- -- -- -- D3 NOTICE-Product Below-Limited Availability(Contact Local Wang Office) 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 AIZ,B1Y,D2,C2X — — — — — 18021 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 Al Z,B1Y Al A1Z,B1Y D1Z,C1Y,D2 D1 — Approved Temperature Ratings Approved Finishes Approved Escutcheons A-135°F(57°C), 155°F(68°C), 175°F 1 -Brass,Chrome,White X-Standard surface-mounted escutcheon or the (79°C),200°F(93°C),286°F(141 °C) Polyester'•°,Black Polyes- Viking Micromatic®Model E-1 Recessed Escutcheon B-135°F(57°C), 155°F(68°C), 175°F ter" Y-Standard surface-mounted escutcheon or recessed with the Viking Micromatice (79°C),and 200°F(93°C) 2-ENT' Model E-1,E-2,or E-3 Recessed Escutcheon C-155°F (68°C), 175°F(79°C),and 3-Chrome Z-Standard surface-mounted escutcheon 200°F(93°C) D-155°F(68°C), 175°F(79°C),200°F (93°C),286°F(141 °C) Footnotes 'Base part number shown.For complete part number,refer to Viking's current price schedule. 'Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing.Other approvals may be in process. °Listed by Underwriters Laboratories Inc.for use in the U.S.and Canada. cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. 'CE:Standard EN 12259-1,Declaration of Performance DOP_Sprinklers_LPCB_5-2-19,DOP_VK302ENT_29-1-20&DOP_VK302-57C_30-9-20. °MED Certified,Standard EN 12259-1,EC-0832-MED-1003. 'Approved according to China GB Standard. DESIGN CRITERIA-UL (Also refer to Approval Chart 1 above.) cULus Listina Requirements: The Viking Microfaste Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT:Always refer to Bulletin Form No. F_091699-Care and Handling of Sprinklers.Also refer to Form No. F_080614 for general care, installation,and maintenance information.Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB,APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 20.07.14 Rev 20.1 Page 5 of 6 NIKING® MICROFASP QUICK TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone:269-945-9501 Technical Services: 877.384-5464 Fax: 269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) Temperature KEY The Viking Microfast®Quick Response Finish Pendent Sprinkler VK302 A Eswtcheon(if appicable) Maximum 175 PSI(12 Bar)WWP Base Part s' SIN Sprinkler Thread Size Nominal K-Factor Overall Length FM Approval Number' Style NPT BSP U.S. metric2 Inches mm (Refer also to Design Criteria.) 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z,B1Y,D2X,C2 21354, VK302 Pendent -- 15 mm 5.6 80.6 2-1/4 58 C3 NOTICE-Product Below-Limited Availability(Contact Local Viking Office) 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z,BIY,D2X,C2 18021 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z,B1Y Approved Temperature Ratings Approved Escutcheons A- 135°F(57°C), 155°F(68°C), 175°F(79°C),200 °F Approved Finishes X - Standard surface-mounted escutcheon or the (93°C),286°F(141 °C) 1-Brass,Chrome,White Polyester°, Viking Micromatic®Model E-1 Recessed Escutcheon B - 135 °F (57 °C), 155°F(68 °C), 175°F(79°C), and and Black Polyester' Y-Standard surface-mounted escutcheon or recessed 200°F(93 C - 155 °F(68 °C), 175 °F(79 °C), 200 °F (93 °C), 286 2-ENT with the Viking Micromatic® Model E-1 or E-2 3-Chrome Recessed Escutcheon °F(141 °C) Z-Standard surface-mounted escutcheon D- 155°F(68°C),175°F(79°C),200°F(93°C) Footnotes ' Base part number shown. For complete part number, refer to Vikings current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing.Other approvals may be in process. 4 Other colors are available on request with the same Approvals as the standard colors. 5 FM approved as corrosion resistant. 6 Approved according to China GB Standard. DESIGN CRITERIA- FM (Also refer to Approval Chart 2 above.) FM Approval Reauirements: The Viking Microfast®Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT:Always refer to Bulletin Form No. F_091699-Care and Handling of Sprinklers.Also refer to Form No. F_080614 for general care, installation,and maintenance information.Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data,the appropriate standards of NFPA, FM Global, LPCB,APSAD,VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 20.07.14 Rev 20.1 Page 6 of 6 Nii uNG® MICROFAST® QUICK TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 42 ' Ceiling Opening Size: 1/2" 2-5/16" (59 mm) minimum (15 mm) � °' 2-1/2" (64 mm) maximum NPT 41 ' t 44 .' 2-1/4" �71 1-3/4 (571mm) i ,q f F, N I! (45 mm) f Installed with a standard 1/8" surface-mounted escutcheon Figure 3: Sprinkler Dimensions with a Standard Escutcheon ,,; Ceiling Opening Size: , 2-5/16" (59 mm) minimum 2-1/2 (64 mm) maximum d.4I 2-1/8" .110 2-1/8" (54 mm) (54 mm) • " 1-1/8' 1-3/4" �,B (291 mm) 2," I (29 mm) (45 mm) Min. (51 mm) Min. Max. Max. ' # ; . Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F 033314 20.07.14 Rev 20.1 Replaces Form No. F_033314 Rev 19.3 (Added ENT to CE Approval.)