Loading...
Permit CITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2021-00389 Date Issued: 09/20/2021 T tG A R D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S106DA12500 Jurisdiction: Tigard Site address: 16614 SW DESCHUTES LN Subdivision: RIVER TERRACE EAST Lot: 125 Project: Nimmala Project Description: Installing 7.3kw solar PV system on rooftop. 20 REC 365AA modules and 10 Chilicon CP720 microinverters. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 e: 0 sf Front: 0 Smoke 0 sf Garage:Height: 0 Bathrooms: 0 Second: g Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $19,000.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Fum<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp SrvclFeeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr. 0 Ea addl 500 st: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: Y Other Description: Roof Top Solar PV System 7.3 kW Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: NIMMALA,PRANEETH REDDY NATIONAL SOLAR INC Required Items and Reports(Conditions) NALLAMADDI,NIKITHA 320 SW CENTURY DRIVE#405-368 16614 SW DESCHUTES LN BEND,OR 97702 BEAVERTON,OR 97007 PHONE: PHONE: 206-877-2818 FAX: Total Fees: $355.69 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR oc,nn LMin fhrm,,n7h'OAR ac9-nMJlnon vnii mat,nkfa in a mew of rhn nape nr AIrPP+nu. tine M�rN INC by nellinn Fna 9Z910R7 nr I Finn TV 94dd Issued By: HOW"VLLY/D ecJe Permittee Signature: (7 YI/Arrairatitlfl Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the lob site at the time of each inspection. R Building Permit Application DECEIVE e — 9 I 1 I '2-1Residential FOR OFFICE USE ONLY SEP yy�t 9y Received p? IlliCity of Tigard 9 bUL] DateBy: 9��s 12� � g permit ZI-�O�p - 7 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review 6/' a` Other Permit: Phone: 503.7182439 Fax: 503.598.1960 t;ITY OF TIGARD Date/By: / Inspection Line: 503.639.4175 Date ReadyBy: `1 orris. ® See Page 2 for 11eAI:U 3UILDING DNISIO 0edlMethod: �'/ Supplemental Information Internet: www.tigard-or.gov i e. , :TYPE OF WO .'y^, *"" .. .•, .- REQU 'ED DAT, • ANI1112-FAMILY DWELLING 0 New construction 0 Demolition Permit fees*arc based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement ®Other:Solar equipment,materials,labor,overhead,and the profit for the work indicated on this application. CATEGORY OF CONSTRUCTIO ) Valuation: $19,000 !Zit-and 2-family dwelling ❑Commercial/industrial Number of bedrooms: ❑Accessory building 0 Multi-family Number of bathrooms: ❑Master builder ❑Other: JOB SITE INFORMATION AND LOCATIONMEI Total number of floors: Job site address:16614 SW Deschutes Lane New dwelling area: square feet City/State/ZIP:Tigard, OR 97007 Garage/carport area: square feet Suite/bldg./apt.no.: Project name:Solar for Nimmala Covered porch area: square feet Cross street/directions to job site: NE of the intersection of SW River Terrace Deck area: square feet Blvd and SW Snowdale St. Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.:2S106DA12500 equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Installing 7.3kw solar pv system on roof of home. 20 REC 365AA modules Valuation: $ and 10 Chilicon CP720 microinverters. Existing building area: square feet New building area: square feet ® PROPERTY OWNER ❑ TENANT Number of stories: Name:Praneeth Nimmala Type of construction: Address:16614 SW Deschutes Lane Occupancy groups: City/State/ZIP:Tigard, OR 97007 Existing: Phone:(510 )709-6652 Fax:( ) New: ® APPLICANT ® CONTACT PERSON m' BUILDING PERMIT FEES* (Please refer to fee schedule) Business name:National Solar Structural plan review fee(or deposit): Contact name:Lynnette Harley/John Harley FLS plan review fee(if applicable): Address:13521 174th St. Ct. E. Total fees due upon application: City/State/ZIP:Puyallup, WA 98374 Amount received: Phone:(253-)359-1444 Fax::( ) PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* E-mail:Id harley@comcast.net Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted Photovoltaic Solar Panel System. Business name:National Solar Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:320 SW Century Dr. #405-388 Solar Installation Specialty Code checklist. Permit Fee(includes plan review $180.00 City/State/ZIP:Bend, OR 97702 and administrative fees): Phone:(503-)915-6757 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lie.:186224 9,4,. Total fee due upon application: $201.60 Authorized si ature: 'Phis permit application expires if a permit is not obtained 3/rl �� within 180 days after it has been accepted as complete. 7/2/2020 *Fee methodology set by Tri-County Building Industry Print name:John H ey Date: Service Board. I:\Building1Permits\BUP-RESPermitApp.doc 02/24/2011 440.4613T(11/02/COM/WEB) • Building Permit Application Checklist a One- and Two-Family Dwelling FOR OFFICE I SE ONI.v - City of Tigard Received 13125 SW Hall Blvd.,Tigard,OR 97223 DateBy. Permit No.: Phone: 503.7182439 Fax: 503.598.1960 Associated permits: I I G A R D 24-Hour Inspection Line: 503.639.4175 13 Electrical ❑ Plumbing ID Mechanical Internet: www.tigard-or.gov 0 Other THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW l es No N/.>: 1 Land use actions completed. Sec jurisdiction criteria for concurrent reviews. 0 0 2 Zoning. Flood plain,solar balance points,seismic soils designation,historic district,etc. 0 ❑ E 3 Verification of approved plat/lot. 0 0 E 4 Fire district approval required. Name of district: ❑ ❑ E 5 Septic system permit or authorization for remodel. Existing system capacity ❑ ❑ E 6 Sewer permit. 0 0 E 7 Water district approval. ❑ ❑ 8 Soils report. Must carry original applicable stamp and signature on file or with application. ❑ ❑ 9 Erosion control ❑plan ❑permit required. Include drainage-way protection,silt fence design and location of catch- ❑ ❑ 0 basin protection,etc. 10 3 Complete sets of legible plans. Must be drawn to scale, showing conformance to applicable local and state 0 ❑ ❑ building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if copyright violations exist. 11 Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if x❑ 0 0 there is more than a 4-ft.elevation differential,plan must show contour lines at 2-ft.intervals);location of easements and driveway;footprint of structure(including decks);location of wells/septic systems;utility locations;direction indicator;lot area;building coverage area;percentage of coverage; impervious area;existing structures on site;and surface drainage. 12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size ❑ ❑ E and location. 13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors,water heater, ❑ ❑ 0 furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc. 14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- 0 ❑ floor,wall construction,roof construction. More than one cross section may be required to clearly portray construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material,footings and foundation,stairs,fireplace construction,thermal insulation,etc. 15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. ❑ ❑ 0 Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope. Full-size sheet addendums showing foundation elevations with cross references are acceptable. 16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non- DOE prescriptive path analysis provide specifications and calculations to engineering standards. 17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing,spacing,and bearing ❑ ❑ 0 locations. Show attic ventilation. 18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered 0 ❑ 111 systems,see item 22,"Engineer's calculations." 19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists DEE over 10 feet long and/or any beam/joist carrying a non-uniform load. 20 Manufactured floor/roof truss design details. Q ❑ ❑ 21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas-piping schematic is required ❑ ❑ 0 for four or more appliances. 22 Engineer's calculations. When required or provided,(i.e., shear wall,roof truss)shall be stamped by an engineer or ❑ ❑ x❑ architect licensed in Ore on and shall be shown to be licable to the ro'ect under review. 23 Three(3)site plans are required for Item 11 above. Site plans must be 8-1/2"x 11"or 11"x 17". 0 ❑ 2 24 Two(2)sets each are required for Items 16, 19,20 and 22 above. DOE 25 Building plans shall not contain red lines or tape-ons. "Mirrored"building plans will not be accepted. ODE 26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. 0 0 0 27 "Drawn to scale"indicates standard architect or engineer scale. ❑ ❑ 0 28 Site plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard 0 0 El Street Tree List. 29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, 0 ❑ E and protection measures must be drawn to scale and must include the project arborist's signature of approval. 30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, ❑ ❑ 0 including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings on a lot of record approved prior to September 9, 1995. L1Building\Permits\BUP-RESPermitApp.doe 02/24/2011 440-4613T(11/02/COMIWEB) v Electrical Permit Applicatio FOR OFFICE USE ONLY City of Tigard ECEIVEC RetivIZEINMIlingli i 13125 SW Hall Blvd.,Tigard,OR 97223 SEP 9 207. Plan Review Related Permit p: • Phone: 503.718.2439 Fax: 503.598.1960Date/B : FIG ARE) Inspection Line: 503.639.4175 vl l l OF �UANL Ready Date/By. lurk. WI See Page 2 for Internet: www.tigard-or.gov Notified/Method: Supplemental Information z; a , . aa�U�titu , ` a PLAN REVIEW . ❑New construction ❑ Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked): 0 Service or feeder 400 amps or more 0 Building over three stones. 0 Demolition ❑X Other: Solar where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings. ® I-and 2-family dwelling ❑Commercial/industrial ❑Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural amps for all other installations. buildings. ❑Multi-family D Master builder ❑ Other: ❑Fire pump. 0 Installation of 150 KVA or JOB SITE INEMIATION AND LOCATION 1=11111111111 ❑Emergency system. larger separately derived ❑Addition of new motor load of system. Job#: Job site address: 16614 SW Deschutes Lane 100HP or more. ❑"A","E","1-2","1-3", ID or more residential units. occupancy. City/State/ZIP:Tlg ard, OR 97007 0 Health-care facilities. 0 Recreational vehicle parks. Suite/bld /a t.#: I Project name:Solar for Nimmala 0 Hazardous locations. 0 Supply voltage for more than g• p J ❑Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job siteNE of the intersection of SW River Terrace 1.1111111r FEE SCHEDULE M. Blvd and SW Snowdale St. DescriptionQrei Each Total New residential single-or multi-family dwelling unit. Subdivision: I Lot#: Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel#:2S106DA12500 Ea.add'1 500 sq.ft.or portion 33.92 1 DESCRIPTION OF WORK Limited energy,residential 75.00 2 (with above sq.ft.) Installing 7.3kw solar pv system on roof of home. 20 REC 365AA Limited energy,multi-family 7500 2 modules and 10 Chilicon CP720 microinverters. residential(with above sq.ft.) Renewable Energy ® See Page 2 ® PROPERTY, WNk' ,;I - :❑ TENANT Services or feeders installation,alteration,and/or relocation Name:Praneeth Nimmala 200 amps or less 100.70 2 Address:16614 SW Deschutes Lane 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 city/State/ZIP:Tigard, OR 97007 601 amps to 1,000 amps 301.04 2 Phone:(510)709-6652 Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email:praneeth0210@gmail.com relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 5936 1 intended for sale, lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: _ Date: 401 amps to 599 amps 168.54 2 Branch circuits—new,alteration,or extension,per panel ® APPLICANT ® CONTACT PERSON A.Fee for branch circuits with Business name:National Solar above service or feeder fee, 742 2 each branch circuit Contact name:Lynnette Harley/John Harley B.Fee for branch circuits without or Address:13521 174th St. Ct. E. service cirfeeder fee,first 56.18 2 City/State/ZIP:Puyallup, WA 98374 Each add'l branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:( 253-)359-1444 Fax::( ) Each manufactured or modular 67.84 2 dwelling,service and/or feeder Email:ldharley@comcast.net Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name:National Solar Sign or outline lighting 67.84 2 Signal circuit(s)or limited-energy ❑ See Page 2 2 Address:320 SW Century Dr. #405-388 panel,alteration,or extension. City/State/ZIP:Bend, OR 97702 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone:(503-) 915-6757 Fax:( ) Investigation(I hr min) 90.00/hr nationalsolarusa.com Industrial plant(1 hr min) 78.18/hr Email:'ohn @ Inspections for which no fee is 90 00/hr CCB Lie.:186224 Electrical Lie.:C 1512 Suprv.Lie.:6051 S specifically listed(%hr min) ELECTRICAL PERMIT FEES Suprv.Electrician signature,required: ram. D Subtotal: Print name: Cody Oram Date:7/12/2020 ❑Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: h TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name: John arle Date:7/12/2020 days after it has been accepted as complete. y * Number of inspections allowed per permit. 1\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015 440-4615T(11/05/COM/WEB e• a Electrical Permit Application—City of Tigard Page 2-Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: tESIDENTIAL WORK ONLY: It? 16FEE SCHEDULE Fee for all residential systems combined: $75.00 Description Qty. Each I 'DAM I y Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 1 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 ❑ Garage Door Opener* >100 kva(fee in accordance • with OAR 918-309-0040) 552.26 2 ❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva-no additional charge 0.0 3 Each additional inspection over allowable in any of the above: • Other: Solar Each additional inspection is charged at an hourly(1 hr min) 6625/hr 1 Inspections for which no fee is 90 00/hr specifically listed('/hr min) COMMERCIAL WORK ONLY: ELECTRICAL_PEkMIT FEES $75.00 Subtotal(Enter on Page I)_ Fee for each commercial system: Number of inspections allowed per permit (SEE OAR 918-309-0000) Check Type of Work Involved: n Audio and Stereo Systems ❑ Boiler Controls n Clock Systems ❑ Data Telecommunication Installation n Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* n Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I:1Building\Permits/ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015