Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
eC,2o2/- 61- " g` '" ie / efi- RECEIVED Aug 122021 AUG 2 6 2021 Performance Summary CITY OF TIGARD BUILDING DIVISION Tag: HP- Model No: RP1442AJ1NA/RH1T4821STANJA Project: City: PORTLAND INTL ARPT State: OR AHRI Ref: 7489180 Altitude: 108 Air Discharge: Upflow/Downflow/Horizontal Cooling Performance AHRI Rating-Capacity:42,500 EER: 11.5 SEER: 14 Ambient Air(F)-Dry Bulb: 87.5 Wet Bulb: 66.5 Airflow(CFM)-CFM: 1,400 SCFM: 1,400 System Entering Air(F)-Dry Bulb: 80 Wet Bulb: 67 % RH: 51.1 System Leaving Air(F)-Dry Bulb: 58.4 Wet Bulb: 57.1 Air Enthalpy(btu/lb)-Entering: 31.4 Leaving:24.5 Design Net Cooling Capacity(btuh)-Total:43,700 Sensible: 32,600 Latent: 11,100 Total Power-Watts:3,445.2 KW: 3.4 Heating Performance AHRI Rating @ High Heating-Capacity: 39,000 COP:3.6 HSPF: 9 Electric Heat Input-KW:9.6 Heating Airflow(CFM)-CFM: 1,400 Air Dry Bulb(F)-Outdoor:29.5 Entering Air:70 Leaving Air: 112.4 Air Temperature Rise(F)-Rise:42.4 Capacity(btuh)-Total:32,755 Total Heating Power-Watts: 63,385 KW: 63.4 Air Moving System Characteristics External Static Pressure(inches WG)-ESP: 0.5 Blower Speed or Speed Tap-Tap: High Drive: Direct Motor Characteristic(watts&BHP)-Power: 399.7 Electrical Supply Ampacity&Overcurrent Protection©230 Volts Outdoor Unit Power Supply(Volt/Hz/Ph)-208-230/60/1 Outdoor Unit Min Ampacity(amps)-24 Max Overcurrent Protection (amps)-Fuse:40 HACR Breaker:40 Field Installed Electric Heater Kit-RXBH-1724?10J Power Supply(Voltage/Hz/Ph)-240/60/1 (Single circuit power supply for air handlers&heaters) Minimum Ampacity(amps)-53 Max Overcurrent Protection (amps)-Fuse: 60 Dimensions, Weight & Clearances Dimensions-Length: 33-3/4 Width: 33 -3/4 Height:27 Outdoor Unit Weight(lb)-Weight:201 Air Handler Dimensions (inches)-Length: 21 11/16 Width:21 Height: 50 1/2 Air Handler Weight(lb)-Weight: 128 Outdoor Unit Clearances(inches)-Sides:24 Top:36 Product Submittal#:421dee1f-42d8-4eb5-b52d-95e0fc63ddcd RUUD Submittal Printed on: 8/18/2021 6:50:34 PM For Model: RP1442AJ1 NA In keeping with its policy of continous progress and product improvement,reserves the right to make changes without notice. Gross capacity does not include the effect of motor heat.AHRI rating is net capacity and includes the effect of fan motor heat.All net capacities also accounts for the effect of motor heat. ASHRAE Weather Data©2009 American Society of Heating,Refrigerating and Air-Conditioning Engineers,Inc.,Atlanta,GA,USA.www.ashrae.org All rights reserved.Used by permission in this program. W . Model: RP1442AJ1NA Unit Dimensions OPERATING SHIPPING MODEL H(Height) L(Length) W(Width) H(Height) L(Length) W(Width) NUMBER INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm RP1418B 25 635 29.75 755 29.75 755 27.90 708 33.25 844 33 838 RP1424A 25 635 29.75 755 29.75 755 27.90 708 33.25 844 33 838 RP1430A 25 635 29.75 755 29.75 755 27.90 708 33.25 844 33 838 RP1436A 27 685 33.75 857 33.75 857 30.08 764 37.64 956 37.56 954 RP1442A 27 685 33.75 857 33.75 857 30.08 764 37.64 956 37.56 954 RP1448A 35 889 33.75 857 33.75 857 38.35 974 37.64 956 37.56 954 RP1460A 39 990 35.75 908 35.75 908 42 1066 39.37 999 39.64 1006 ALLOW 60"[1524 mm] OF CLEARANCE A 1 R D __ ♦'ice � ' V tilateri‘' GRE 41 -A111-19- \ _A ev--- :•...,- .• ..,,,,,,._.e. /i #1// H ��r `_ _IS = = . !...."-.----:___. ...T. ir , ........... ,..... ._.ar ,,," 1_- \10. ____ AIR INLET LOUVERS ALLOW SERVICE PANELS/ INLET CONNECTIONS/HIGH&LOW VOLTAGE ACCESS ALLOW 24"[610 mm]OF CLEARANCE 6"[152 mm]MIN.OF CLEARANCE ALL SIDES 12"[305 mm]RECOMMENDED [ 1 Designates Metric Conversions ST-Al 226-02-00 Model: RP 1442AJ 1 NA RP14**A Series Efficiencies: 14 SEER/11.5 EER 8.2 HSPF _.:. '' Nominal Sizes 11/2 to 5 Ton [5.28 to 17.6 kW] . Cooling Capacities 17.3 to 60.5 kBTU *-� . ' [5.7to17.7kW] ". c �L us I J =7= -- 1� LISTED „`+s _ E Pa "Proper sizing and installation of equipment is critical to achieve `mar ..fir• optimal performance." J ,, r t l j • New composite base pan-dampens sound,captures louver • Integrated heat pump lift receptacle-allows standard CPVC I panels,eliminates corrosion and reduces number of fasteners stands to be inserted into the base needed I • PlusOneTm Triple Service Access-15"wide, industry lead- I • Improved tubing design-reduces vibration and stress,mak- ing corner service access-makes repairs easier and faster. ing unit quieter and reducing opportunity for leaks The two fastener removable corner allows optimal access to • Optimized defrost characteristics-decrease defrosting and internal unit components. Individual louver panels come out provide better home comfort once fastener is removed,for faster coil cleaning and easier i • Powder coat paint system-fora long lasting professional finish cabinet reassembly Optimized reversingvalve sizing • Diagnostic service window with two-fastener opening- • . -improves shifting perfor- provides access to the TXV valves and the heat pump revers- mance for quieter unit operation and increased life of the ing valve before opening the unit. system • Enhanced mufflers-help to dissipate vibration energy for • External gauge port access-allows easy connection of quieter unit operation "low loss"gauge ports • Scroll compressor-a sound abating feature added to the • Single-row condenser coil-makes unit lighter and allows thor- compressor significantly reduces noise when system transi- ough coil cleaning to maintain"out of the box"performance I tions in and out of defrost mode • 35%fewer cabinet fasteners and fastener-free base-allow • Modern cabinet aesthetics-increased curb appealfor faster access to internal components and hassle-free with visu panel removal ally appealing design • Curved louver panels-provide ultimate coil protection, • Service trays-hold fasteners or caps during service calls enhance cabinet strength,and increased cabinet rigidity • QR code-provides technical information on demand for • Optimized fan orifice-optimizes airflow and reduces unit faster service calls sound • Fan motor harness with extra-long wires-allows unit top to • Rust resistant screws-confirmed through 1500-hour salt be removed without disconnecting fan wire spray testing I. • PlusOneTM Expanded Valve Space-3"-4"-5"service valve f - space-provides a minimum working area of 27-square inches for easier access I ;. 1 Model: RH 1 T4821 STANJA Unit Dimensions ELECTRICAL CONNECTIONS SUPPLY AIR NOTE:24"CLEARANCE REQUIRED IN FRONT OF MAY EXIT TOP OR EITHER SIDE UNIT FOR FILTER AND COIL MAINTENANCE. HIGH VOLTAGE CONNECTION Ve.[22.2 mm]. lehf[27.8 mm],tm/ef[50 mm]DIA.KNOCKOUTS. lochs' \,,,\ [262m I ./��� LOW VOLTAGE CONNECTION .' s/e"[15.9 mm]AND Ve'[22.2 mm]KNOCKOUT / �����- Return Air Opening Dimensions . - Model Return Air Return Air Opening • - o Cabinet Size Opening Width Depth/Length p (Inches) (Inches) R • 0 17 157/8 193/4 o n 21 193/8 193/4 24 227/s 193/4 'I . * K AUXILIARY DRAIN CONNECTIONe/i[19.1 mm]FEMALE PIPE THREAD(NPT) HORIZONTAL APPLICATION ONLY PRIMARY DRAIN CONNECTIONa/e^[19.1 mm]FEMALE PIPE THREAD(NPT) • • • AUXILIARY DRAIN CONNECTION Vi[19.1 mm]FEMALE PIPE THREAD(NPT) 19Vx'[495 mm] UPFLOW/DOWNFLOW APPLICATION ONLY RETUPN Alfl • . OPENING 21"/mm LIQUID LINE CONNECTION jai\\\ �F [551 mm] COPPER(SWEAT) VAPOR LINE CONNECTION COPPER(SWEAT) UPFLOW UNIT SHOWN: UNIT MAY BE INSTALLED UPFLOW,DOWNFLOW, ! • HORIZONTAL RIGHT OR LEFT AIR SUPPLY. I 515/14" t [151�mm] 4Ve" • `�� • �.ri?� [105[mm][76/r m] 13/1s',[48 mm]1Ve"[29 mm], �% HORIZONTAL ADAPTER KIT P `� �' 1 [27 mm 1 13/81 • [35 mm] >• 213hs"--. [71 mm] _ VAPOR LINE 71•JtsiT---- ��; �-5/e"-- CONNECTION �j /j (136 mm] AUXILIARY HORIZONTAL 1 Ali a f., ,� UPFLOW UNIT SHOWN: DRAIN CONNECTION �I,-.' _ 6� n1! -t• « �,>, UNIT MAY BE INSTALLED UPFLOW, ��=�+� Ar �!: DOWNFLOW,HORIZONTAL RIGHT 12.�VW \ p4�� OR LEFT AIR SUPPLY. • w%I' [ ]Designates Metric Conversions ( )Designates Unit with Double Coil Cabinet PRIMARY DRAIN LIQUID LINE VERTICAL DRAIN PAN CONNECTION CONNECTION AUXILIARY UPFLOW/DOWNFLOW— DRAIN CONNECTION e . Model: RH 1 T4821 STANJA Unit Dimensions&Weights Refrigerant Connections Air Flow Unit Weight/Shipping Weight Model Sweat(In.)1mm]ID Unit Unit Supply CFM(Nom.)[L/s] (Lbs.)[kg] Size Width Height Duct RH1T Liquid Vapor "W"In.[mm] "H"In.[mm] "A"In.[mm] Lo Hi Unit With Coil(Max.KW) 2417ST 3/8[9.53] 3/4[19.05] 171/2[445] 421/2[1080] 16 [406] 600[283] 800[378] 92/106[42/48] 3617ST 3/a[9.53] 3/4[19.05] 171/2[445] 421/2[1080] 16 [406] 1000[472] 1200[566] 96/110[44/50] 3621HT 3/8[9.53] 7/8[22.23] 21 [533] 57 [1448] 191/2[495] 1000[472] 1200[566] 137/149[62/68] 3621MT 3/8[9.53] 7/8[22.23] 21 [533] 501/2[1282] 191/2[495] 1000[472] 1200[566] 126/142[57/64] 4821 MT 3/8[9.53] 7/8[22.23] 21 [533] 57 [1448] 191/2[495] 1400[661] 1600[755] 139/151 [63/68] 4821ST 3/8[9.53] 7/6[22.23] 21 [533] 501/2[1282] 191/2[495] 1400[661] 1600[755] 128/144[56/65] 4824ST 3/8[9.53] 7/8[22.23] 241/2[622] 501/2[1282] 23 [585] 1600[755] — 142/160[64/72] 6021 ST 3/n[9.53] 7/8[22.23] 21 [533] 57 [1448] 191/2[495] 1600[755] 1725[814] 139/151 [63/68] 6024ST 3/8[9.53] 7/e[22.23] 241/2[622] 551/2[1410] 23 [585] — 1800[850] 159/176[72/80] *Maximum dehumidification airflow. Unit Dimensions&Weights Refrigerant Connections Air Flow Unit Weight/Shipping Weight Model Sweat(In.)[mm]ID Unit Unit Supply CFM(Nom.)[L/s] (Lbs.)[kg] Size Width Height Duct RH2T Liquid Vapor "W"In.[mm] "H"In.[mm] "A"In.[mm] Lo Hi Unit With Coil(Max.KW) 2421 MT 3/n[9.53] 3/4[19.05] 21 [533] 421/2[1080] 191/2[495] 525[248] 700[330] 111/126[50/57] 3621MT 3/8[9.53] 7/8[22.23] 21 [533] 501/2[1282] 191/2[495] 800[377] 1050[495] 129/145[59/66] 4824MT 3/8[9.53] 7/8[22.23] 241/2[622] 551/2[1410] 23 [584] 1050[495] 1400[660] 128/146[58/66] 6024ST 3/8[9.53] 7/8[22.23] 241/2[622] 551/2[1410] 23 [584] 1200[566] 1600[755] 161/178[73/81] [ ]Designates Metric Conversions V Model: RH 1 T4821 STANJA RH1T/RH2T- Series Constant Torque Motor(ECM) Efficiencies up to 16 SEER A'~ C L US LISTED • RH1T/RH2T feature a Constant Torque motor(ECM)which • 11/2 ton[5.3 kW]through 5 ton[17.6 kW]models are between provides enhanced SEER performance with most Rheem out- 421/2 to 57 inches[1080 to 1448 mm]tall and 22 inches door units. [559 mm]deep. • Versatile 4-way convertible design for upflow,downflow, • All models meet or exceed 330 to 400 CFM[156 to 189 Vs] horizontal left and horizontal right applications. per ton at.3 inches[.7 kPa]of external static pressure. • Factory-installed indoor coil. • Enhanced airflow up to.7"external static pressure. • Sturdy cabinet construction with 1.0 inch[25.4 mm]of • Evaporator is constructed of aluminum fins bonded to inter- foil faced insulation for excellent sound and insulating nally grooved aluminum tubing. characteristics. • Suitable for application in mobile homes. • Field-installed auxiliary electric heater kits provide exact heat for indoor comfort.Kits include circuit breakers which meet U.L.and cUL requirements for service disconnect.