Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
��87�5.sk_ ps672=1° 8-62a2i 0653 RECEIVED AUG 16 2021 6 Amp and 10 Amp, 24 Volt Power Supplies CITY OF TIGARD 3UILDING DIVISION The PS Series are independently configurable power supplies, allowing you to pair any input with any output, and feature LED diagnostics for troubleshooting. The PS Series is a remote power supply line from Silent Knight and is a direct replacement for the 5495/5499.The SK-PS6 is a 6 amp and the SK-PS10 is a 10 amp,remote power supply with battery charger that may be connected to any 12 or 24 volt fire alarm control panel(FACP)or used as a standalone power supply.The PS Series provides 24 VDC power for NACs(notification appliance circuits)configured as either Class B or Class A(requires the ZNAC-PS option card)with multiple sync protocol options.The PS Series also provides auxiliary power,constant or resettable,suited for detectors,annunciators,door holders,and other fire alarm system peripherals.The PS Series cabinet can hold two 7 AH or 18 AH batteries and can charge up to 33 AH batteries in a separate cabinet. FEATURES AND BENEFITS • Up to five(6 amp model)or seven(10 amp power supply,or a control module,single or corrosion-resistant powder coat chip and model)independently-configurable,power- multi,which may be housed within the scratch-resistant finish limited output circuits for: power supply cabinet • Cabinet designed with ten double —Class B and/or Class A NACs • Ability to cascade up to four power supplies knockouts and a removable door for ease of —Class B and/or Class A resettable or non- • Two(6 amp model)or three(10 amp model) installation and wiring resettable 24V auxiliary power fully-isolated input/control circuits which • Includes integral battery charger capable of —door holder power can be programmed to any output charging up to 33 AH batteries • Converts from Class B to Class A wiring • Two Form C normally-closed trouble relays • Cabinet can house two 7 AH or 18 AH without losing any outputs using the ZNAC- for AC Trouble and General Trouble batteries PS converter card(sold separately) • 6 or 10 amp full load output,respectively, • Battery charger may be disabled via DIP • Optimal for powering four-wire smoke with 3 A maximum/circuit switch for applications requiring larger detectors,annunciators,and other system • Individual NAC power and trouble LEDs for batteries and external battery charger peripherals requiring regulated power diagnostic efficiency • Removable terminal blocks accommodate • Optional addressable control,monitor,and • Trouble history mode for diagnostic support up to 12 AWG(3.1mm2)wire relay modules and power-supervision relay • Wide range end-of-line supervision value • Works with any UL 864 FACP which utilizes (EOLR-1) (normal.2-27K ohms) an industry-standard reverse-polarity • Configurable for ANSI°Temporal 3 or • Selectable earth fault detection(enable or notification circuit Temporal4 coded output disable) • UL-Listed NAC synchronization using • AC trouble report delay timer System Sensor`,Wheelock,Gentex or • Completely configurable via onboard DIP AMSECO°appliances switches,no extra software required • Synchronization can be triggered from • Self-contained in compact,locking cabinet Honeywell FACP NAC/remote sync outputs,cascaded constructed of heavy gauge steel with a ®SILENT' KNIGHT ORDERING INFORMATION SK-PS6:6.0 A,120 VAC remote charger power supply in a lockable, metal enclosure,red SK-PS10:10.0 A,120 VAC remote charger power supply in a lockable,metal enclosure,red ZNAC-PS:Optional Class A converter card,sold separately SK-CONTROL:Addressable Control Module for one Class B or Class A zone of supervised,polarized Notification Appliances. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. SK-RELAY:Addressable relay module containing two isolated sets of Form-C contacts,which operate as a DPDT switch SK-MONITOR:Addressable Monitor Module for one zone of normally open dry-contact initiating devices.Includes plastic cover plate and end-of-line resistor.Module may be configured for either a Class B or Class A SK-MONITOR-2:Dual Monitor Module.Same as SK-MONITOR except it provides two inputs for Class B wiring only SK-RELAYMON-2:Provides two monitored inputs and two Form-C relays.Functions in Class B wiring only SK-CONTROL-6:Six-circuit supervised control module SK-RELAY-6:Six Form-C relay control module EOLR-1:12/24 VDC end-of-line relay for monitoring four-wire smoke detector power BAT-1270-BP:Battery,12 volt,7.0 AH,5-pack(two required) BAT-12180-BP:Battery,12 volt,18AH,2-pack BAT-12330:Battery,12 volt,33AH SEISKIT-MULTI-1:Seismic kit for the PS Series.Includes bracket and hardware for two 7AH or two 18AH batteries. Page 2 of 3—SK-61095:C•3/10/2021 SK-PS6 / SK-PS1O TECHNICAL SPECIFICATIONS PRIMARY(AC) POWER SECONDARY POWER(BATTERY) SK-PS6:120 VAC,50/60 Hz,5.0A CHARGING CIRCUIT Silent Knight'and System Sensor` maximum • Supports lead-acid batteries only are registered trademarks of SK-PS10:120VAC,50/60 Hz,6.2 A • Float-charge voltage:27.6 VDC Honeywell International,Inc. Wheelock'is a registered trademark maximum • Maximum current charge:1.5 A g Wire Size:#12-14 AWG with 600 V • Maximum battery capacity:18 AH(inside of Cooper Technologies Company. nsulation cabinet) Gentex'is a registered trademark of COMMAND INPUT CIRCUIT • Maximum battery charging capacity:33 AH Gentex Corporation.AMSECO is a (external cabinet) registered trademark of Potter Trigger Input Voltage:9 to 32 VDC Electric Signal Company,LLC. Trigger Current:2.0 mA(16-32 V);Per PHYSICAL ANSI''is a registered trademark of Input:1.0 mA(9-16 V) Dimensions:20.0"H x 14.5"W x 3.5"D(cm: the American National Standards RELAY CIRCUITS 50.8H x 36.83W x 8.9D) Institute,Inc. Weight:with two 7Ah batteries is 24 pounds ©2021 by Honeywell International Trouble Contact Rating:4 A at 24 VDC (10.9 kg),with two 18 AH batteries is 39 Inc.All rights reserved. OUTPUT CIRCUITS pounds(17.7 kg) Unauthorized use of this document • 24 VDC filtered STANDARDS AND CODES is strictly prohibited. • SK-PS6:TB8-TB9-1A Regulated,3A The SK-PS complies with the following This document is not intended to be special applications;TB10-TB12-0.3A standards: used for installation purposes.We Regulated,3A special applications NFPA 72:National Fire Alarm Code try to keep our product information • SK-PS10:TB8-TB11-1.5A Regulated,3A to-date and accurate.We cannot UL 864:Standard for Control Units for Fire up-to-date applications;TB12-TB14-0.3A Alarm Systems(NAC expander mode) cover all specific applications or Regulated,3A special applications anticipate all requirements.All • 6.0 A(SK-PS6)or 10.0(SK-PS10)maximum UL 1481:Power Supplies for Fire Alarm p Systems specifications are subject to change total continuous current for all outputs without notice. AGENCY LISTINGS AND APPROVALS Country of origin:USA These listings and approvals apply to the modules specified in this document.In some cases,certain modules or applications may not be listed by certain approval agencies,or listing may be in process.Consult factory for latest listing status. UL Listed:S3511 CSFM:7315-0559:0522 FDNY Approved FM Approved Honeywell Silent Knight 12 Clintonville Road Northford,CT 06472-1610 Honeywell 203.484.7161 SK-61095 I C 103/21 ®SILENT' www.silentknight.com '©2021 Honeywell International Inc. KNIGHT • SYSTEM SENSOR` Indoor Selectable- Output Strobes and .: . Horn Strobes for A:} Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut " for installation times and maximize profits with lower current draw and modern aesthetics. 407 ')rh, Features The System Sensor L•Series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela The entire L-Series product line of ceiling-mount strobes and horn • Field-selectable candela settings on ceiling units: strobes include a variety of features that increase their application 15,30,75,95, 115, 150,and 177 versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- • Universal mounting plate for ceiling units consuming ground faults. • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring,installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING APPROVED LISTED S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383 L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 1 Y-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit°"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 115, 150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDsessoo UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 Volts Volts Switch Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS86B00 L-Series Dimensions 2.47 1.37111M111 0 6.92 2.50 06.83 1\1 OYIIOT►►I� I'I Ir Q O Q\1 r ,,1 I I 1•r \,..,_8 7 ( 08 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box 41,47-117:-Illibl•- .---- i I� • 0 1 INILa :.-41::-2-, it !II% ...,.. .. . , �,..,irtri.07, ....,, ..... 1 _ , . V� i Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire,Horn Strobe,Red SCRL Strobe,Red PC2WL 2-Wire,Horn Strobe,White SCWL Strobe,White SCWL-CLR-ALERT Strobe,White,ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White SYSTEM ©2017 System Sensor. 1 3825 Ohio Avenue•St.Charles, IL 60174 Product specitiGallons subject tc change without notice.Visit systemsensoccom ._ SENSOR Phone:800-SENSOR2•Fax:630-377-6495 for current product information,including the latest version of this data sheet. AVDS86801•03/17