Loading...
Report RECEIVED FEB 012021 SUBMITTAL CITY OF TIGARD BUILDING DIVISION Job Name: BKM Management Job Site: BKM Management Tigard, OR 97223 United States Architect: Ken McCracken Architect Engineer: Riverside Engineering Consultant: Johnson Air Products Contractor: River City NW Mechanical Elevation: (ft) 108 Date: 1/15/2021 Submitted By: Josh Gross JOHNSON AIR PRODUCTS 2220 SE 9TH AVE PO BOX 15098 PORTLAND, OR 97293 US Phone: (503)234-5071 Fax: (503)233-0451 Email Address: jgross@johnsonair.com GREENHECK Building Value in Air. P.O. Box 410 Schofield, WI 54476 (715) 359-6171 FAX(715) 355-2399 www.greenheck.com Generated by:jgross@johnsonair.com CAPS 4.34.1071 G:\JoshGross\2021 Secured\River City NW Mech\BKM Management.gfcj Page 1 of 3 1 , .. 1 , . tH Printed Date: 01/15/2021 GREENHECK Job: BKM Management Building Value in Air. Mark: EF-1 Model: SP-B110 1 14.938 -I Model: SP-B110 -1'� j Ceiling Exhaust Fan �1,( ) i 4.5 ° 13.375 Standard Construction Features: i -Corrosion resistant galvanized steel scroll and housing-White designer non- ! I -- - j ...I / yellowing grille-Round outlet duct collar with integral backdraft damper-Single inlet forward curved wheel-Plug type disconnect-Adjustable mounting brackets Selected Options &Accessories: Motor rated for continuous use Motor with Thermal Overload Motor with CSA Approval 06115 Motor with 40 Degree C Ambient Temperature 13.875 .. - 1.25 UL/cUL 507 Listed Electric Fan MOUNTING i Round Duct Connection Adjustable easy installation mounting bracket BRACKET '- 1.i L Designer Grille y �i Polypropylene Wheel Material 'Nj1 li � Can Be Used to Comply with:ASHRAE 62.2 and Washington State Energy Code Dimensional Quantity I 1 Weight w/o Acc's(lb) 10 Weight w/Ace's(lb) 10 1.2 h ` — — / _ Performances • Requested Volume(CFM)T 100 Actual Volume(CFM)� —98 --- 0.9 / T Total External SP(in.wg) 0.227 _ Fan RPM 950 C *FLA(A) 1.15 m 06 m Elevation(ft) 108 N a Airstream Temp.(F) 70 i C hro Air Density(Ib/ft3) 0.075 u g ) Sones 1.5 m 0.3 m c'/c° systen` 0.0 - - 0 20 40 60 80 100 120 140 Motor Volume(CFM) Motor Mounted Yes `; Operating point at Total External SP **Input Watts(V\J) 80 Fan curve Voltage/Cycle/Phase 115/60/1 - System curve Enclosure ODP *FLA is Note All pproximate and will vary slightly with the motor. WORLDWIDE ns shown are in units of in. ramcci / Sones-calculated using AMCA 301 at 5 ft CERTICIED ! *"Wattage is shown at free air. ,, RRTIOGf -- "Wattage is approximate and may vary between motors. %$OUAD y nil : P(NOR A+DOI 2100._ R ♦ 1 Hill AnVEB Mr ♦♦ min connot N. CERTIFIED ,��'w.,;„. Generated by:jgross@johnsonair.com CAPS 4 34.1071 G:\JoshGross\2021 Secured\River City NW Mech\BKM Management.gfcj Page 2 of 3 1 GREENHEGK Printed Date: 01 Job: BKM Management t LN, Building Value in Air. Mark: EF-2 Model: SP-B110 -- 15.625 - 14.938 Model: SP-B110 - -,1 I 3 l 1 Ceiling Exhaust Fan I. I �i;.,, �) v 4 5 , \ ; 13�375 Standard Construction Features: \ r -Corrosion resistant galvanized steel scroll and housing-White designer non- . i E- I.N yellowing grille-Round outlet duct collar with integral backdraft damper-Single r ---t - inlet forward curved wheel-Plug type disconnect-Adjustable mounting brackets Selected Options &Accessories: Motor rated for continuous use Motor with Thermal Overload Motor with CSA Approval h 11.5 Motor with 40 Degree C Ambient Temperature , - ,.. --1.25.� — 13.875 � -06 UL/cIJL 507 Listed-Electric Fan I Rndnd Duct Connection MOUNTING BRACKET Adjustable easy installation mounting bracket J` i r i Designer Grille r ; 1 Polypropylene Wheel Material ' t (r Can Be Used to Comply with:ASHRAE 62.2 and Washington State Energy Code Dimensional Quantity 1 Weight w/o Acc's(lb) 10 Weight w/Acc's(lb) 10 1.2 --- ____... ...._.___. / Performance Sp Requested Volume(CFM) 100 --- — 0.9 Actual Volume(CFM) 98 .C'Q Total External SP(in.wg) 0.227 '�� Fan RPM 950 C *FLA(A) 1.15 0.6 m Elevation(ft) 108 N b Airstream Temp.(F) 70 T. m Air Density(Ib/ft3) i 0.075 .o ..C.- . Sones i 1.5 in 0.3 b �? 0/ SYstem . _ 0.0 - - 0 20 40 60 80 100 120 140 Motor Volume(CFM) Motor Mounted r Yes Operating point at Total External SP **Input Watts(W) 80 Fan curve - — - - -System curve---------- — ------- Voltage/Cycle/Phase 115/60/1 Enclosure ODP Notes: All dimensions shown are in units of in. Iamc %� *FLA is approximate and will vary slightly with the motor. WORLDWIDE. ' Sones-calculated using AMCA 301 at 5 ft IOERTIi1ED!' **Wattage is shown at free air. RRTIRGf/ **Wattage is approximate and may vary between motors. I\ / SOUAD • C / iii .ttrcrtminiR 4100■. nip ems. 4 CERTIFIED =:::Z,,u :,J Generated by:jgross@johnsonair.com CAPS 4.34.1071 G:\JoshGross\2021 Secured\River City NW Mech\BKM Management.gfcj Page 3 of 3