Loading...
Report (3) Bend Office (541)330-9155 Geotechnical Office (503)601-8250 Eugene Office (541)345-0289 Carlson Testing� Inc. Salem office (503)589-1252 Tigard Office (503)684-346o84-3460 Daily Report of Proprietary Anchors Project: POLYGON AT ROSHAK RIDGE-LOT 9 CTI Job#: Ti8o4799•AH Address: 14309 SW 168TH AVE TIGARD OR Jurisdiction: TIGARD CTI representative: Darell Martini was on this site on date: o4/0i/2o2o to perform Special Inspection for Permit: MST2o19-00076 PO#: SCOPE OF INSPECTION Location of concrete placement[to include grid lines,elevations(floors) 1. Checked in with superintendent or client representative: and drawing details]: 1.REVIEWED THE FOLLOWING DOCUMENTS; Name: KALEB A.A7,NO REVISION,2-18-19 Company: POLYGON B.FOR STAMPED LETTER DATED 5-1 5-r 4 DETAILING HDU2 HOLD DOWN CRITERIA. 2.MONTTORED POLYGON INSTALL(`t EA)5/8"X 2 4" 2. Inspection was'IBC ❑X Continuous ❑Periodic A3o7 THREADED ROD,6"EmBEDmENT FORHDU2 HOLDDOWN IN GARAGE FOUN)AION NO DISCREPANCIES PROPRIETARY ANCHORS WERENOTED. Yes No N/A 1.Reviewed previous inspection reports? X REPORT SUMMARY 2.Reviewed evaluation report? X 1. Work inspected : ❑X Completed ❑In Progress Verified following items meet manufacturer's published installation 2. Crlxpletedwork inspected ❑X was ❑was not in compliance materials. with Yes No N/A 3.Verified minimum embedment depth of the anchors? X ❑X Approved plans and specifications Shop❑ Drawings 4.Verified installation of the anchors? X ❑RFI ❑Design Change ❑Submittal ❑N/A 5.Verified anchor diameter? X Doc.No(s): SEE TEXT Dated: 04/01/2020 6.Verified steel grade? X 7.Verified hole diameter? X 3• Noncompliance item(s)were noted this date,details on the following 8.Verified type of drill bit used? X page(s): Yes ❑X No ❑N/A 9.Verified hole cleaning method? X 4. Noncompliance item(s)were reinspected this date,details on 10.Verified adhesive application? X following page(s)❑Yes ❑X No ❑N/A 11.Verified edge distance? X ❑Conform ❑Remain in progress 12.Verified spacing? 13.Verified installation torque? X Report(s)findings were discussed and left with KALEB Evaluation report number and date: ESR 2508,1-2020 of POLYGON Name of product being installed: SIMPSON SET XP Batch Number: 1000034232 Expiration Date: 03/27/2021 Based on the code,approval is required from the Building Official before the SPECIAL INSPECTED items noted above can be covered. Carlson Testing has no authority to direct work of contractors and subcontractors. ❑See xklitional report pays) Distribute Attactumnt(s) Pro}niamy Anchors Version 1 Page 1 of 1