Report OFFICE COPY 2021.00, RECEIVED Ilvqu0i EQUIPMENT SUBMITTAL 7J COURTYARD MARRIOTT L,'IYOFIIGARD 3UILDING DIVISION Tigard, OR PFP Job# 32-15966 ITEM MANF. MODEL SIZE COMMENTS *** SPRINKLERS *** Standard Fast Resp. Rec. Pend. Reliable F1FR 56 1/2" Chrome-155' Residential Recessed Pendent Viking VK430 1/2" White - 155' Ext. Coverage Fast Resp. dry HSW Reliable DH56 1" Chrome - 200' Standard Fast Resp. Dry HSW Reliable F3QR 1/2" Chrome - 155' Standard Upright Reliable G 1/2" Bronze-200' *** PIPE *** Screwed End State Pipe Sch 40 1" Black& Galvanized CPVC Pipe Blazemaster Sch 40 3/4"- 1 1/4" *** FITTINGS *** Screwed Smith Cooper Varies 1" Black CPVC Blazemaster 3/4"- 1 1/4" *** HANGERS *** CPVC Afcon varies Ring Hanger Grinnell fig. 69 Threaded Rod Anchor Elco ZH665 3/8" horizontal wood Sway Brace Attachment Tolco fig. 4L Sway Brace Attachment Tolco fig.825 Sway Brace Attachment Tolco fig.980 Sway Brace Attachment Tolco fig. 1001 ATRIOT Bulletin 014 Rev. L co Reliabld Model F1 FR Series Quick Response Standard Spraycp 1- Model F1FR56 Sprinkler Types IT; cy Standard Upright 1. A Standard Pendent Conventional Vertical Sidewall ft Horizontal Sidewall r'^ Model Fl FR56 Recessed Sprinkler Types Upright Pendent Conventional Standard Pendent/F1/F2/FP -�-. Horizontal Sidewall Model F1FR56 Concealed Sprinkler Types41110411 ' 4" . Standard Pendent Asia._ Model F1FR42, F1 FRXLH & F1FR28 Sprinkler Vertical Sidewall Horizontal Sidewall Recessed Types Pendent/F1/F2 Standard Upright Standard Pendent Model F1FR42, F1 FRXLH & Fl FR28 Recessed ' , i ,_.< A d, Sprinkler Types , ' : t 4k. ft Standard Pendent '', Model F1FR56LL&F1FR42LL Low Lead Sprinkler Recessed Concealed Recessed Types* Horizontal Sidewall Pendent Pendent/FP Standard Pendent Less than 0.25% Lead Content w‘ - - Listing & Approvals 1. Underwriters Laboratories Inc. and Certified for ,'s i. Canada(cULus). 2. Factory Mutual Approvals (FM) XLH Upright XLH Pendent XLH Recessed 3. Loss Prevention Council (LPCB, UK) PendentF1/F2 4. VdS Schadenverhutung GmbH F1FR42, F1FR42LL, F1FRXLH & 5. *NSF Certified to NSF/ANSi Standard 61 Annex G F1FR28 Series sprinklers to apply wa 6. EC Certificate: 0786-CPD-40239 (RA1414), 0786 ter to a fire much faster than standard CPD 40251 (RA1425), 0786 CPD 40252 (RA1475) sprinklers of the same temperature rat- i ot.` • UL Listing Category ing. Sprinklers, Automatic&Open (VNIV) The glass bulb consists of an accu- Quick Response Sprinkler rately controlled amount of special fluid XLH Recessed Product Description hermetically sealed inside a precisely Pendent FP Reliable Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, manufactured glass capsule. This glass bulb is specially F1 FRXLH & F1FR28 Series Sprinklers are quick response constructed to provide fast thermal response. sprinklers which combine the durability of a standard sprin At normal temperatures, the glass bulb contains the fluid kler with the attractive low profile of a decorative sprinkler. in both the liquid and vapor phases. The vapor phase can The Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, be seen as a small bubble. As heat is applied, the liquid F1FRXLH & F1FR28 Series Recessed automatic sprinklers expands, forcing the bubble smaller and smaller as the liq utilize a 3.0 mm frangible glass bulb. These sprinklers have uid pressure increases. Continued heating forces the liquid demonstrated response times in laboratory tests which are to push out against the bulb, causing the glass to shatter, five to ten times faster than standard response sprinklers. opening the waterway and allowing the deflector to distrib This quick response enables the Model F1FR56, F1FR56LL, ute the discharging water. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard re- sponse sprinklers should not be intermixed. *Pin tl e (XLH Only) Deflector "AG fir Load Screw Washer Bulb Frame / Cup "ii, 1 014FG06A Model F1FR42, F1FRXLH Upright Technical data: Thread Max. Min. Temperature Models Discharge Coefficient Response Size Working Working Rating Finish Pressure Pressure F1FR56 **F1FR56LL!'t K5.6 F1FR42 1/2" NPT See e **F1 FR42LL!'t K 4.2 Resuick po se (R1/2) 175 PSI 7 PSI "Temperature "Finish Table" F1 FRXLH Ratings"Table. F1 FR28 K 2.8 0)Low Lead Sprinklers available only with Temperature Rating 200°F/93°C Material Data: Frame Deflector Load Screw *Pintle Cup Washer Bulb DZR Brass CDA Alloy 260, CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360 QM Brass CDA Alloy 220 or or or coated with PTFE Adhesive GlassOr **Low Lead Brass CDA AlIoy510 CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape 2. Model F1 FR56, Upright, Pendent & Conventional Sprinklers Model F1 FR42, F1FRXLH & F1FR28 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Thread Nominal K Factor Sprinkler Approval Sprinkler Identification Number Nominal p (SIN) Orifice Size US Metric Height Organization Upright Pendent Standard-Upright(SSU)and Pendent Deflectors Marked to Indicate Position 1/2"(15mm)0 1/2" NPT(R1/2) 5.6 80 2.25" (57mm) 1, 2,3, 4, 6 RA1425(1x2)(3x4) RA14140x'x30) 7/16"(10mm) 1/2" NPT(R1/2) 4.2 60 2.25"(57mm) 1 RA14230)r4J RA1413(4) 3/8" (10mm) 1/2"NPT(R1/2) 2.8 40 2.25"(57mm) 1 RA1421"x4) RA1411(4) Conventional-Install in Upright or Pendent Position 15mm 0) 1/2" NPT(R1/2) 5.6 80 57mm 3, 4, 6 RA1475(3) 0)cULus listed corrosion resistant(Polyester coated)sprinkler. (2)Polyester coated FM approved sprinkler. (3)Polyester coated LPCB&VdS approved sprinkler RA1425,RA1414&RA1475. (4)Electroless Nickel PTFE(Teflon®)*Plated -cULus listed Corrosion Resistant , , 6. • ifi ,„ z.... tez-77 ,r.,-,- Upright Pendent Conventional Model Fl FR56LL & F1 FR42LL Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Thread Nominal K Factor Sprinkler Approval Sprinkler Identification Number Nominal p (SIN) Orifice Size US Metric Height Organization Pendent Standard-Pendent Deflectors Marked to Indicate Position 1/2"(15mm)0) 1/2" NPT(R1/2) 5.6 80 2.25" (57mm) 1, 5 RA1415 7/16"(11mm) 1/2" NPT(R1/2) 4.2 60 2.25"(57mm) 1, 5 RA1410 (')cULus listed corrosion resistant(Polyester coated)sprinkler. Olii, , *DuPont Registered Trademark 3. Model Fl FR56, Fl FR42, Fl FRXLH & Fl FR28 Quick Response Recessed Pendent Sprinkler(') Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Thread K Factor Sprinkler Sprinkler Identification Number _ Orifice Size US Metric Height (SIN) 1/2"(15mm) 1/2" NPT(R') 5.6 80 2.25" (57mm) RA1414 7/16"(10mm) 1/2"NPT(R1/2) 4.2 60 2.25"(57mm) RA1413 3/8"(10mm) 1/2" NPT(R1/2) 2.8 40 2.25"(57mm) RA1411 (1,Refer to escutcheon data table for approvals&dimensions Model F1FR56LL & F1FR42LL Quick Response Recessed Pendent Sprinkler)') Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Thread K Factor Sprinkler Sprinkler Identification Number Orifice Size US 1 Metric Height (SIN) 1/2"(15mm) 1/2"NPT(R1 ) 5.6 80 2.25"(57mm) RA1415 7/16"(10mm) 1/2" NPT(R1/2) 4.2 60 2.25"(57mm) RA1410 0)Refer to escutcheon data table for approvals&dimensions I I O.x VI'REDUCER r '- SSA'DK(66.lmn) N —--a� r�z[IN MARC , r J x rM'ncam r N. 4 1 WIS.ON.(H)mm, y ' r maTO PACE OF CS RIO Alrpry' LGIP _c p7�/ 1 1 fs- 1r1T J ` Ili FAff O'i1PMIC Llll/�J 1 QS$CLAWI a v.mmJ 1171,lii W F J ,iZ.— l 1, nn rscuvuT T- 2:11 7. aiiiiiii Ar ruxaxr� trzss- r-r/...nr4 m1 .aysnienr 1 111_ lll,II!5V J Ar up,wXl.rcEs9 YxP.s,..I E��. I Ar MURMUR/rta.0. r21.t.�mm) } lL J, .r... 7�t1 1��itL III ill - Ai J J *7 1F* At w.rwuu RECESS.9/rl7ralmmJ ICIZY �1�1!� Ar 4w,MW xfL£SC.i S 1}'rr l.lmml .P_-.....___.. V R I Ft£RV2'iNiY( AW2IYEIV} AI. Al ARMOUR RECESS. Sif ET IRJ ...ol. Ar rww,v vEass., _ i _ l r/l al rr-1 Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH& Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH& F1FR28 F1 or F2 F1FR28 FP Model F1FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Nominal K Factor Sprinkler Approval Sprinkler Orifice Thread Size US Metric Height ' Organizations Identification Numbers(SIN) 1/2'(15mm) 1/2' NPT(R1/2) 5.6 80 2,25"(57mm) 1,2, 3 2j3J 15mm 1/2" NPT(R1/2) 5.6 80 2.25"(57mm) 3(1r RA1485 ")LPC Approval is for pendent position only. (2)cULus Listed corrosion resistant(Polyester coated)sprinkler. (3)Electroless Nickel PTFE(Teflon®)"Plated -cULus listed Corrosion Resistant 3'% Sprinkler Type Deflector to Ceiling Distance (Min.-Max.) 11011, Upright 4"(102mm)-12"(305mm) Pendent 4"(102mm)- 12"(305mm) I 7 � Vertical Sidewall 'DuPont Registered Trademark 4 Model Fl FR56 Quick Response Horizontal Sidewall Sprinkler Deflector: HSW Installation Wrench: Model D Sprinkler Wrench Installation Data: Horizontal Sidewall Nominal K Factor Sprinkler Approval Organizations Height and Type of Approval Sprinkler Nominal Orifice Thread Size Identification (SIN) US Metric Light Hazard Ordinary ( ) Hazard f1/2"(15mm) 1/" NPT(R1/2) 5.6 80 2.63" (67mm) 1, 2 1 RA143507(2)(3) 01)cULus Listed corrosion resistant(Polyester coated)sprinkler. (4 Polyester coated FM approved sprinkler. ce Electroless Nickel PTFE(Teflon)'Plated -cULus listed Corrosion Resistant FACE OF FITTING TO FACE OF CEILING DIMENSION N. Fl ESCUTCHEON AT MAXIMUM RECESS = I T25.4mm] AT MINIMUM RECESS = 3/879.5mm] FI ESCUTCHEON F2 ESCUTCHEON AT MAXIMUM AT MINIMUM RECESS = 7�1%67524mm] AT MAXIMUM RECESS = 3/47I9mm] _ AT MINIMUM RECESS = 3/879.5mm] F2 ESCUTCHEON it AT MAXIMUM RECESS = 1-5/8741.3m] �11�, m 2 1/4"HOLE 0/4. f 1/8" AT MINIMUM RECESS = 2-1/1 6 752.4mm] [57.2mm] [3.2mm] I"X 1/2"REDUCER 'I Horizontal Sidewall r -� p , I �,] 4"-l2" 1 15/16"01A. f [49.2mm] i " ce - ---- 2 27/32"DIA. ()O7.CEILINGOTO8mm] ` ' -{' [722mm] DEFLECTOR TURN COLLAR UNTIL III TIGHT AGAINST SPRINKLER WRENCH BOSS. ,l\Y f) ESCUTCHEON 3/4719mm)ADJUSTMENT H 1F2/2"(12ESCUTC7mmEON]ADJUSTMENT RECESSED HSW W/F1 OR F2 ESCUTCHEON w (1) FM APPROVED FOR 4" -- 6"[I01.6MM - 152.4MM]CEILING TO DEFLECTOR WITH F2 ONLY. Note: For Recessed HSW Sprinklers use installation wrench GFR2. cULus permits use with F1, F2 or FP escutcheons for "Light Hazard" only.While FM limits use for the same hazard with the F2 escutcheon only. Model Fl FR56 Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: "K" Factor Temp. Rating Max. Sprinkler Nominal Thread Bulb Orifice US Metric Size Model S rinkler Cover Ambient Color Approvals Identification p Temp Number(SIN) 1/2"(15mm) 5.6 80 1/2" NPT F1FR 135°F/57°C 135°F/57°C 100°F/38°C Orange 1 RA1414 Y2"(15mm) 5.6 80 1/2" NPT FIFA 155°F/68°C 135°F/57°C 100°F/38°C Red 1,411),6 RA1414 1/2"(15mm) 5.6 80 1/2" NPT F1FR 175'F/79°C 165°F/74°C 100°F/38°C Yellow 1 RA1414 1/2"(15mm) 5.6 80 Y2" NPT F1FR 200°F/93°C 165F/74°C 150°F/65°C Green 1 RA1414 I')For VdS only= 155°F/68°C Norbulb and 1/2" [12,7mm]adjustment. Model Fl FR56LL Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: "K" Factor I Temp.Rating Max. Sprinkler Nominal Thread Model Ambient Bulb Approvals Identification Orifice US Metric Size Sprinkler Cover Temp Color Number(SIN) ' 1/2"(15mm) 5.6 80 1/2"NPT F1FR56LL 200°F/93°C 165°F/74°C 150°F/65°C Green 1,5 RA1414 *DuPont Registered Trademark 5. 1"x 1/2"REDUCING 1"x 1/2"REDUCING TEE OR ELBOW �_ -� TEE OR ELBOW � .._.._.._.._..r Tr. 11 I ill.._.._.. 11 I ll - - 2 5/8"DIA. -`- '_ r ` 2 5/8" DIA. 2 5/16" DIA - ' s -.--� ROLE IN CEILING 2 5/16"DIA — NOLE IN CEILING CUP A I CUP fs• -77A IIII LI1II,I# I 1/2"MAX. — — I lk l_3e1III 1 I/2t MAX. FACE OF FITTING -;I FACE OF FITTING _TO FACE OF CEILING flfl _ TO FACE OF CEILING '•lit 1HJi1T•• t !II T ::: DIMENSION 11 N 1. �- "' DIMENSION tQ 1 �` 111i CEILING 111 CEILING T ♦. --if 5 1D MAX. T __- alp' 3/4" //2 MAX -� � 15/16"' COVER ADJUSTMENT COVER ADJUSTMENT ( COVER PLATE— COVER PLATE— I ASSEMBLY 5 5/16" DIA. ASSEMBLY 3 5/16" DIA. SPRINKLER SPRINKLER—1 CONCEALED. 1/2" ADJUSTMENT nwwou CONCEALED. 5/16" ADJUSTMENT o,.,m.. Figure 1 Figure 2 Installation Aid A protective cap is included for use during installation. gagement. A choice of two cover plate assemblies provide Important: The F1FR56 Sprinkler with Model CCP cover either 1/2"(13mm)or 5/8"(8mm)of cover adjustment, plate is not an FM Approved combination. Do not install these sprinklers in ceiling which have positive Installation pressure in the space above. Quick response sprinklers are intended for installation as After a 25/e" (67mm) diameter hole is cut in the ceiling, the specified in NFPA 13. Quick response sprinklers and stan- sprinkler is easily installed with the Model RC1 Wrench. A dard response sprinklers should not be intermixed. Teflon*based thread sealant should be applied to the sprin- The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, kler threads only. The Model RC1 Wrench is then used to F1FRXLH & F1FR28 Recessed Quick Response Sprin- engage the sprinkler wrenching surfaces and to install klers are to be installed as shown. The Model F1 or F2 Es- the sprinkler in the fitting. When inserting or removing the cutcheons illustrated are the only recessed escutcheons wrench from the sprinkler/cup assembly,care should be tak- to be used with the Model F1FR56, F1FR56LL, F1FR42, en to prevent damage to the sprinkler. DO NOT WRENCH F1FR42LL, F1FRXLH & F1FR28 Sprinklers. The use of any ON ANY OTHER PART OF THE SPRINKLER. The cover other recessed escutcheon will void all approvals and ne- plate is then pushed onto the cup. Final adjustment is made gate all warranties. by hand turning the cover plate until the skirt flange makes When installing Model F1FR56, F1FR56LL, F1FR42, full contact with the ceiling. Cover plate removal requires F1FR42LL, F1FRXLH & F1FR28 Sprinklers, use the Model turning in the counter clockwise direction. D Sprinkler Wrench. Use the Model GFR2 Wrench for install- After installation, inspect all sprinklers to ensure that there ing F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & is a gap between the cover plate and ceiling and that the F1FR28 Recessed Pendent Sprinklers. Any other type of four cup slots are open and free from any air flow impedi- wrench may damage these sprinklers. ment to the space above. NOTE: A leak tight 1/2' NPT (R1/2) sprinkler joint can be Concealed cover plate/cup assemblies are listed only for obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do use with specific sprinklers. The use of any other concealed not tighten sprinklers over maximum recommended torque. cover plate/cup assembly with the Model F1FR56 Pendent It may cause leakage or impairment of the sprinklers. Sprinkler or the use of the Model CCP Concealed cover The Models F1 FR56/CCP & F1 FR56LL/CCP Concealed plate assembly on any sprinkler with which it is not specifi- Sprinkler use the Y" orifice, 1/2" NPT (R1/2), Model F1FR56 cally listed my prevent good fire protection and will void all &F1FR56LL Pendent Sprinkler with a threaded Model CCP guarantees,warranties, listings and approvals. cup which is factory attached to the sprinklers. The Model Glass bulb sprinklers have orange bulb protectors to F1FR56 Pndent is available in temperature rating of 135°F minimize bulb damage during shipping, handling and in- (57°C), 155°F (68°C), 175°F (79°C) or 200°F (93°C). The stallation. REMOVE THIS PROTECTION AT THE TIME THE Model F1FR56LL Pendent is available only in a rating of SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE 200°F(93°C).The concealed sprinkler assemblies are corn- PROTECTION. Removal of the protectors before this time pleted by the installation of the attractive low profile Model may leave the bulb vulnerable to damage. RASCO wrench- CCP push on cover plate assembly, rated 135°F (57°C) or es are designed to install sprinklers when covers are in 165°F(74°C)for the F1FR56 and 165°F(74°C)for the FIFR56 place. REMOVE PROTECTORS BY UNDOING THE CLASP LL.The cover plate and sprinkler cup assemblies are joined BY HAND. DO NOT USE TOOLS TO REMOVE THE PRO- using a cover plate skirt with flexible tabs for threaded en- TECTORS. *DuPont Registered Trade Mark 6. . Temperature Ratings Finishes(1) Sprinkler Max.Ambient Standard Finishes Classification Temperature Bulb Color Sprinkler Escutcheon Cover plater') °CTemp. °F Bronze , Brass Chrome Ordinary 57 135 100°F(38°C) Orange Chrome Plated Chrome White Ordinary 68 155 100°F(38°C) Red Polyester Plated Intermediate 79 175 150°F(66°C) Yellow Coated(4)(5)(6) White Painted Intermediate 93 200 150°F(66°C) Green Special Application Finishes High(1) 141 286 225°F(107°C) Blue Sprinkler Escutcheon Cover plater') (1)Not available for recessed sprinklers. Electroless Nickel Electroless Nickel Bright Brass PTFE(Teflon®)'(7( PTFE(Teflon®)" g Escutcheon Data (1) Bright Brass(3) Bright Brass Black Plating (1)SIN RA1435-cULus permits use with Ft F2 or FP escutcheons for"light Black Plated Black Plated Black Paint hazard"only,while FM limits use for same hazard with F2 escutcheon only Black Paint(2)(6) Black Paint Off White Off White(2)(6) Off White Satin Chrome Maintenance Chrome Dull Chrome Dull The Model F1 FR56, F1 FR56LL, F1 FR42, F1 FR42LL, rn Other finishes and colors are available on special order. Consult the F1 FRXLH and Model F1 FR56, F1 FR56LL, F1 FR42, factory for details.Custom color painted sprinklers may not retain their F1 FR42LL, F1 FRXLH&F1 FR28 Recessed Sprinklers should UL Corrosion resistance listing.Coverplate custom paint is semi-gloss, be inspected and the sprinkler system maintained in accor- 2 unless specified otherwise. dance with NFPA 25. Do not clean sprinklers with soapand (3) 200°FLus Listed3°°C)only. p 200°F(93 C)maximum. water, ammonia or any other cleaning fluids. Remove dust (4) cULus listed "corrosion resistance" applies to SIN Numbers RA1435 by using a soft brush or gentle vacuuming. Remove any (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and sprinkler which has been painted (other than factory ap RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. plied) or damaged in any way. A stock of spare sprinklers (5) FM Approvals finish as"Polyester coated"applies to SIN Number should be maintained to allow quick replacement of dam- RA1414,RA1435 and RA1425 in standard black or white, aged or operated sprinklers. Prior to installation, sprinklers `6'LPCB and VdS Approved finish applies onlytoRA1425,RA1414 and RA1475. should be maintained in the original cartons and packaging " cULus listed Corrosion Resistant to minimize the potential for damage to sprinklers that would Ordering Information cause improper operation or non-operation. Specify: 1. Sprinkler Model Sprinkler Types 2. Sprinkler Type Standard Upright 3. Orifice Size • Standard Pendent 4. Deflector Type Conventional 5. Temperature Rating Recessed Pendent 6. Sprinkler Finish Vertical Sidewall 7. Escutcheon Type Horizontal Sidewall 8. Escutcheon Finish (where applicable) Recessed Horizontal sidewall 9. Cover plate Model Concealed pendent 10. Cover plate Thread size 11. Cover plate Temperature Maximum Working Pressure 12. Cover plate Adjustment 175 psi (12 bar) 13. Cover plate Finish 100% Factory tested hydrostatically to 500 psi (34,5 bar) Note:When Model F1 FR56 Recessed sprinklers are ordered,the sprinklers and escutcheons are packaged separately. *DuPont Registered Trademark 7. Reliable. . . For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gauges • Electrical sprinkler alarm switches • Identification signs • Water flow detectors • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled )431-1588 Sales Offices Paper Reilabid 880000 848-6051 Sales Fax (914)829-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.09/14 P/N 9999970300 Page 1 of 5 NIIKING® FREEDOM® RESIDENTIAL TECHNICAL DATA PENDENT SPRINKLER VK430 (K4.3) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1. DESCRIPTION Viking Freedom®Residential Pendent Sprinkler VK430 is a thermosensitive, glass-bulb residential sprinkler available in several different finishes and temperature ratings to meet varying design requirements. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed = as corrosion resistant as indicated in the Approval Chart. The orifice design, with a K-Factor of 4.3 (62 metric*), allows efficient use of available water supplies for the hydraulically designed fire-protection system. The fast response type glass bulb and special deflector combine speed of operation and area of coverage to meet residential sprinkler standards while being aesthetically pleasing. 2. LISTINGS AND APPROVALS 4t UL Listed (C-UL-US-EU): Category VKKW --- NYC Approved: MEA 89-92-E, Volume 24 Refer to the Approval Chart on and Design Criteria for C-UL-US-EU Listing require- WARNING:Cancer and Reproductive Harm ments that must be followed. (.\ www P65Warnings.ca gov 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 4.3 U.S. (62 metric*) *Metric K-factor measurement shown is for when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to-65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Brass UNS-C26000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Compression Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Pip Cap Attachment(for QM Brass sprinklers only): Brass UNS-C36000 For ENT coated sprinklers: Belleville spring-Exposed. Screw and Pineal)-ENT plated. Available Finishes and Temperature Ratings: Finish Brass Chrome White Polyester Black Polyester ENT Suffix A F M-/W M-/B JN Temperature 155°F(68°C) 175°F(79°C) Suffix Ordering Information: (Refer to Table 1.) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. Form No. F_082095 19.02.21 Rev 18.2 .P65 Replaces Form No. F_082095 Rev 18.2 (Removed F-1 Escutcheon.) Page 2 of 5 NIKING FREEDOM® RESIDENTIAL TECHNICAL DATA PENDENT SPRINKLER VK430 (K4.3) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 7. AVAILABILITY The Viking Model VK430 Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: ORDERING INFORMATION Instructions: Using the sprinkler base part number, (1) add the suffix for the desired Finish (2) add the suffix for the desired Temperature Rating. Size 1: Finishes 2: Temperature Ratings Sprinkler Base Part NPT BSP Max.Ambient Ceiling No. Inch mm Description Suffix' Nominal Rating Bulb Color Temperature' Suffix 09530 1/2 -- Brass A 155 °F (68 °C) Red 100 °F (38 °C) B Chrome F 175 °F (79 °C) Yellow 150 °F (65 °C) D White Polyester 4,5 M-/W Black Polyester 4,5 M-/B ENT 65 JN Example: 09530AB =VK430 with Brass Finish and 155°F (68°C) Nominal temperature rating.This sprinkler is to be installed into an area with a maximum ambient temperature of 100 °F (38 °C) meaning if the area will experience temperatures above the maximum ambient rating, you shall use a higher temperature-rated sprinkler. Accessories Sprinkler Wrenches (see Figure 1): A. Standard Wrench: Part No. 21475M/B. B. Recessed Socket Wrench: Part No. 13655W/B2. C. Protective Sprinkler Cap/Escutcheon installation tool6 15915. Sprinkler Cabinet: A. Up to 6 sprinklers: Part number 01724A. B. 6-12 Sprinklers: Part number 01725A. Footnotes 1_ VVhere a dash(-)is shown in the Finish suffix designation,insert the desired Temperature Rating suffix.See example above. 2. Requires a 1/2"ratchet which is not available from Viking. 2. Based on NFPA 13, NFPA 13R,and NFPA 13D.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction.Refer to specific installation standards. 4 UL Listed as corrosion resistant. 5. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart.These tests cannot and do not represent all possible corrosive environments.Prior to installation,verify through the end-user that the coatings are compatible with or suitable for the proposed environment.For automatic sprinklers,the ENT coating is applied to all exposed exterior surfaces, including the waterway. 6. Allows installation from the floor by attaching a length of 1"diameter CPVC tubing to the tool.Ideal for sprinkler cabinets. Refer to Bulletin F_051808. • Form No. F_082095 19.02.21 Rev 18.2 .P65 • Page 3 of 5 . NIKING® FREEDOM® RESIDENTIAL TECHNICAL DATA PENDENT SPRINKLER VK430 (K4.3) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart Viking VK430, 4.3 K-Factor Residential Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13,refer to the design criteria on page 5. For Ceiling types refer to current Editions of NFPA 13, 13R or 13D Sprinkler NPT Thread Size Nominal K-Factor Maximum Water Overall Length Base Part SIN 2 WorkingPressure Number' Inches mm U.S. metric Inches mm 09530 VK430 1/2 15 4.3 62 175 psi (12 bar) 2-1/4 58 Ordinary Temp Rating Intermediate Temp Rat- Listings and Approv- Max. Cover- (155°F/68°C) ing (175°F/79°C) als 3 Minimum age Area' Deflector Installation Spacing acing Ft.X Ft. Flow' Pressure' Flow" Pressure4 to Ceiling Type Ft. (m X m) GPM PSI GPM PSI 0 5 NYC7 NSF' (m) (Umin) (bar) (Umin) (bar) COus .. 12 X 12 12 7.8 12 7.8 (3.7 X 3.7) (45.4) (0.54) (45.4) (0.54) 14 X 14 13 9.1 13 9.1 Standard (4.3 X 4.3) (49.2) (0.63) (49.2) (0.63) surface- mounted 16 X 16 13 9.1 13 9.1 escutch- (4.9 X 4.9) (49.2) (0.63) (49.2) (0.63) eons or See See ' 1-1/8 to 2 recessed Foot- See Foot- 8 18 X 18 17 15.6 17 15.6 Foot- inch(5.5 X 5.5) (64.4) (1.08) (64.4) (1.08) with the Mi- note 6 note 6 note (2.4) cromatic® and 10 6 Model E-1, E-2,or E-3 20 X 20 21 23.9 21 23.9 Recessed (6.1 X 6.1) (79.5) (1.64) (79.5) (1.64) Escutcheon Footnotes +. Part number shown is the base part number. For complete part number,refer to Viking's current price schedule. 2. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa,divide the metric K-factor shown by 10.0. J. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional ap- provals. Refer also to Design Criteria on page 5. 4. For areas of coverage smaller than shown,use the"Flow"and"Pressure"for the next larger area listed. Flows and pressures listed are per sprinkler. 5. Listed by Underwriter's Laboratories,Inc.for use in the U.S., Canada,and European Union. e. Approved Finishes are: Brass.Chrome,White Polyester,and Black Polyester 9. 7. Accepted for use,City of New York Department of Buildings,MEA Number 89-92-E,Vol.24. a- UL Classified to: NSF/ANSI Standard 61, Drinking Water System Components(MH48034). °. Other paint colors are available on request with the same C-UL-US-EU listings as the standard finish colors. '0. Approved finish is Electroless Nickel PTFE(ENT). ENT is C-UL-US-EU Listed as corrosion resistant. ENT is available with standard surface-mounted escutcheons or the Micromatic Model E-1 Recessed Escutcheon. Form No. F_082095 19.02.21 Rev 18.2 .P65 Page 4 of 5 ' NIKING @ FREEDOM® RESIDENTIAL • TECHNICAL DATA PENDENT SPRINKLER VK430 (K4.3) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESIGN CRITERIA (Also refer to the Approval Chart on page 3.) UL Listing Reauirements IC-UL-US-EUI: When using Viking Residential Pendent Sprinkler VK430 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of coverage and minimum water supply requirements shown in the Approval Chart on page 3. For systems designed to NFPA 13:The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers.The mini- mum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart on data page 3 for NFPA 13D and NFPA13R applications for each listed area of coverage,Q • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the"design area"in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. • Minimum distance between residential sprinklers: 8 ft. (2.4 m). IMPORTANT:Always refer to Bulletin Form No. F_091699 -Care and Handling of Sprinklers.Also refer to Form No. F_080190, F_080814, and F_080415 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. B A °>=1111.110 1 Figure 1: Sprinkler Wrenches Carefully slide the wrench le' �' sideways around the protective cap,ensuring engagement with the sprinkler wrench flats. Sprinkler Wrench 13655W/B**for installing - recessed pendent sprinklers f— (A 1/2" ratchet is required. ~ Not available from Viking.) Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No. F_082095 19.02.21 Rev 18.2 .P65 Page 5 of 5 - NIKING® FREEDOM® RESIDENTIAL TECHNICAL DATA PENDENT SPRINKLER VK430 (K4.3) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Ceiling Opening Size: 2-5/16" (59 mm) minimum 1/2" e . (15 mm) ;, 2-1/2" (64 mm) maximum NPT '. • r; Or'4.'fv.. v• 2-1/4" 1, (57 mm) �t 1-314" (45 mm) •.� iikt Installed with a standard 1/8" surface-mounted escutcheon Figure 3: Sprinkler Dimensions with a Standard Surface Mount Escutcheon Ceiling Opening Size: ^(' 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum • 2-1/8" 2-1/8" (54 mm) (54 mm) •• 1-1/8" � 1-1/8" 1-3/4" (29 mm) 2" (29 mm) (45 mm) Min. (51 mm) Min. Max. • Max. : Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_082095 19.02.21 Rev 18.2 P65 Replaces Form No. F_082095 Rev 18.2.P65 (Removed F-1 Escutcheon.) Bulletin 016 Rev.F Model DH56 HSW OD ® Model DH56 HSW Recessed Reliabl Model DH56 HSW Concealed Quick Response, C Extended Coverage Dry Sprinklers -n For coverages up to 28 feet wide and 10 feet longt'>. 250 psi (17,2 bar) rated. Features: 1. Coverage for long and narrow spaces such as hallways, •~ corridors, decks and rooms up to 28 feet wide and 10 feet long.') - 2. Deflector to ceiling dimensions are: 4"(102mm)min.to 12" (305mm)max. DH56 HSW(See Fig. 4) 3. Minimum spacing between sprinklers 16 feet(4.9m).(1" 4. Polyester Coated Corrosion Resistant Sprinklers(cULus) 5. UL Listed for extended coverage,light hazard applications. 6. 5.6 K Factor. 7. Sprinkler is approved for 250 psi(17,2 bar)applications. 8. Quick response performance. 9. 1/2' (13mm)adjustment of escutcheon and cover. 10.Concealed cover plate can prevent the sprinkler from being used for unintended purposes.No exposed thermal element DH56 HSWMB(See Fig.5) with the concealed version. 11.Push-on/thread-off sturdy convenient escutcheon for recessed and cover for concealed. 12.Factory assembled sprinkler&cup,shipped complete with bulb protector for concealed and FP recessed versions. 13.Sprinkler & cup assembly and escutcheon or cover are separately packaged. r- 14.Cover finishes available in standard white paint, special bronze, black paint or flat white paint. DH56 HSW FP Recessed(See Fig.6) 0 )See Fig. 9. Approval Organizations 1. Listed by Underwriters Laboratories Inc. and UL certified for Canada(cULus) k 2. NYC MEA 258-93-E Patents US Patent No. 7,841,418 Other Patents Pending DH56 HSW Concealed with SWC coverplate(See Fig. 7) Products Description have Yz" adjustment. The SWC cover plate is attached with The Model DH56 are quick response extended cover- 135 & 165 degree solder. In the event of a fire the rising age sidewall dry sprinklers for use in light hazard applica- ambient temperature melts the solder and the cover plate is tions. The Model DH56 dry sprinkler with SWC cover plate ejected away by springs exposing the 3mm frangible glass is a concealed sprinkler that uses Reliable's push on/thread bulb. The use of a 3mm bulb allows quick response which off sidewall cover.This sprinkler has the cup factory mounted enables the sprinkler to apply water to a fire sooner than stan- and is shipped with a bulb protector that protects the 3mm dard response sprinklers of the same temperature rating. frangible glass bulb during shipping and post installation fin- Model DH56 dry sprinklers are intended for use in dry and • ishing operations. The DH56 can be combined in the field preaction systems to protect areas subjected to freezing tern- with the FP or F2 Escutcheon to make a recessed dry sprin- peratures and unheated portions inside buildings.See Fig. 1 kler. The SWC cover plate, FP and F2 recessed escutcheons for guidelines on using dry sprinklers in wet systems. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 • Environments wherein dry sprinklers are employed can DH56 HSW Recessed with FP Escutcheon be corrosive. For this reason, Model DH56 dry sprinklers To install the DH56 HSW dry sprinkler with the FP Escutch- have a special wax fillet placed in the gap between the eon as a recessed sprinkler cut a 25/8" diameter hole in the • cup that supports the bulb and the wrenching boss. This wall as shown in Fig.6. Temporarily remove the plastic pro- wax will not interfere with the operation of the sprinkler,and tective cap,and then use the Model XL02 wrench(see Fig. it prevents contaminants from entering the internal portion 2)to tighten the sprinkler until it is secured in the sprinkler of the drop nipple. The wax must not be removed. fitting. Note: The Model XL02 wrench has a notch in it to accommodate the deflector top. This wrench can only be Application inserted one way. Care must be taken not to damage the The Model DH56 is a horizontal sidewall dry sprinkler deflector during tightening. Apply a Teflon** based seal- intended for installation in light hazard occupancies in ac- ant to the sprinkler threads before installing in the sprinkler. cordance with NFPA 13. These sprinklers are designed to Wrench only on the square boss. DO NOT WRENCH ON provide fire protection in long and narrow spaces such as ANY OTHER PART OF THE SPRINKLER. It is recommended hallways, corridors, decks and rooms up to 28 feet (8,5m) that the sprinkler be protected during plastering and paint- wide and 10 feet(3m)long. They are rated for 250 psi(17,2 ing operations by reinstalling the plastic protective cap. In- bar) and can be mounted between 4 and 12 inches (102 stallation is completed by removing the protective cap and and 305mm)down from the ceiling. inserting the push-on escutcheon.Turn clockwise to adjust General Installation Instructions the escutcheon against the wall. Model DH56 dry sprinklers must be installed only in Stan- DH56 HSW Concealed with SWC Cover Plate dard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) To install the DH56 HSW dry sprinkler with the SWC pipe tees in the horizontal position,even at branch line ends. coverplate as a concealed sprinkler, cut a 21/8' diam- They should not be installed into elbows or pipe couplings eter hole into the wall as shown in Fig. 7. Temporari- located on drop nipples to the sprinklers. For these and ly remove the plastic protective cap, and then use the other fittings including CPVC, the dry sprinkler should be Model XL02 wrench (see Fig. 2) to tighten the sprinkler installed into a fitting to allow protrusion into the fitting in ac- until it is secured in the sprinkler fitting. Note: The Model cordance with the diagrams. The "A" dimension of the dry XL02 wrench has a notch in it to accommodate the de- sprinkler, which extends into a freezing zone from wet pipe flector top. This wrench can only be inserted one way. systems, should be selected to provide, as a minimum, the Care must be taken not to damage the deflector during specified lengths in inches shown in Fig. 1. tightening. Apply a Teflon** based sealant to the sprinkler Caution threads before installing in the sprinkler. Wrench only on . Do not install Model DH56 HSW Dry sprinklers into CPVC the square boss. DO NOT WRENCH ON ANY OTHER adapter fittings or tees that have an internal obstruction. PART OF THE SPRINKLER. It is recommended that the This will damage the sprinkler and/or the fitting. Refer to sprinkler be protected during plastering and painting op- Fig. 8 erations by reinstalling the plastic protective cap. Instal- lationDH56 HSW is completed by removing the protective cap and inserting the coverplate. Coverplate assemblies provide To install the DH56 HSW dry sprinkler cut a 21/8" diameter /z" (13mm) of adjustment. Final adjustment is made by hole in the wall as shown in Fig. 4. Use the Model F3 instal- turning the coverplate clockwise until the skirt flange lation wrench (see Fig. 3) to tighten the sprinkler until it is makes full contact with the wall surface. Cover removal secured in the sprinkler fitting. Apply a Teflon* based seal- requires turning in the counter-clockwise direction. ant to the sprinkler threads before installing in the sprinkler. Concealed coverplate assemblies are listed only for Wrench only on the square boss. DO NOT WRENCH ON use with specific sprinklers. The use of any other con- ANY OTHER PART OF THE SPRINKLER. Installation is com- cealed wall sprinkler or the use of the SWC coverplate pleted by removing the orange glass bulb-protector and as- on any sprinkler with which it is not specifically listed will sembling the slip-on escutcheon to the sprinkler's can. void all guarantees, warranties, listings and approvals. DH56 HSW/HB Note: DH56 and DH56 Recessed Sprinklers have or- To install the DH56 HSW/HB dry sprinkler cut a 21/2"diam ange bulb protectors to minimize bulb damage during eter hole in the wall as shown in Fig. 5. Use the Model F3 shipping, handling, and installation. REMOVE THIS PRO- installation wrench (see Fig. 3) to tighten the sprinkler until TECTION AT THE TIME THE SPRINKLER SYSTEM IS it is secured in the sprinkler fitting. Apply a Teflon* based PLACED IN SERVICE FOR FIRE PROTECTION. Remov- sealant to the sprinkler threads before installing in the sprin- kler. Wrench only on the square boss. DO NOT WRENCH vulnerable to damage. RASCO wrenches are designed ON ANY OTHER PART OF THE SPRINKLER. Installation is to install sprinklers when covers are in place. REMOVE completed by removing the orange glass bulb protector PROTECTORS BY UNDOING THE CLASP BY HAND. DO and assembling the slip-on escutcheon to the sprinkler's NOT USE TOOLS TO REMOVE THE PROTECTORS. can. *DuPont Registered Trademark 2. ir RECOMMENDED MINIMUM EXPOSED BARREL LENGTH BASED ON AMBIENT TEMPERATURE IN THE PROTECTED AREA (STANDARD DH56 HSW DRY SPRINKLER SHOWN) EXPOSED BARREL ARNIM M EM 1EIPEPATWE TEMPERATURE OF PROTECTED 40P/PC I SOT/ICED 16vFALIT AREA, DE OSCFURA(TE END EXPOSED WORN MIREL LENGTH,* OF ow SPRNIOER (FACE CF LEE 10 TOP OF CERDN:) N.OM 6L MC N. (ICU) 417F(4a) 0 0 0 JO•F(-1E) 0 0 0 20F(-PO) 4(101) 0 0 10'F(-12C) B(203) 1 (25.1) 0 •M MIEI{ft®1 0•f(-tea) 12(305) 3(75) 0 EIMMILN XPOSED -1OF(-23C) 14(356) 4(101) 1 (25.1) BARREL -205(-25C) 14(Je6) 6(152) J LEHGi1H , ,,,,,,t•:• ESCUTCHEON -50F(-34E) 16(406) 6(203) 4(101) i .,..1 -40F(-40C) 16(457) 6(205) 4(101) , •1 -50F(—RTC) 20(506) 10(254) 6(152) ; • •::'; -SOF(-51C) 20(506) 10(254) 8(152) S. '•''•'''•"•'•'•'•'•'•'•'► T •THE PROTECTED AREA REFERS TO TIE AREA 551.06 THE CEILING. ^+.. .� ' S •T MOO IS DE TEMPERATURE AT THE 06 ILING. 1�: l I ' _. OV.. FOR PROTECTED AREA TEMPERATURES THAT OCCUR BETTIF N TE AWES 1� .!•� LISTED.USE THE)ENT COOLER 1EMPQNTME 14............. ... .. "TIE MN REWIRED BARREL IENGIH IS NOT THE SALE AS TE•A•OYENSW. METE ::'::1':•:::11::::::::::::::::::::':::::::::::::::1111114 HOLE:EXPOSED&6)1 BAREL LENGTHS ME NCIIISNE UP ro JOMMI PPE :: ;;;,;;,;;,;,4IRN VETOCTES N TIE PROTECTED AREA. .•' ••• • •• • ••, Q 1IRLIED AWN NSTALL 1 NCH RFT THREADED 1....•........ ,•.:.g....,. 1 ENO OF DRY PENDENT SPRINKLER 1"' •• • , NTO TIE 1 INCH PIPE SLOE OUTLET OF A RU.ERNE NON TEE FROND PER M®B 165(CLASS 150) VALL OR CAST NON TRENDED TEE FTTRNO PER NISI 16.4(CUSS 125)ONLY. MUTATED FREEZER OR COOLER STRUCTURE IF IEIQATY AND TEMPERATURE DDFULMI NL OR COMM FIAINNO CAUSES CENCOISATIEN W TIE EXPOSED DRY SPFO/6LER,CRSIE.R VRAPPDE0 TEE EXPOSED BARREL WITH INSULATION FOAN DISCLAIM TAPE OR EQUIVALENT. SEAL THE Cl FPRsuts SPACE MIMI THE SPRDSQ AVOID ER TO LEAKAGE CIF AIR INTO THE PROTECTED AREA AM CONSEQU T FORMATION I CONDENSATE AROUND DE ARE FRAME.VRCH COULD WORT CPERATI OR CASE PE TATOE O'ERATIO4 SEE TIELOV FOR REL06lTDED METHODS. . RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS (STANDARD DH56 HSW DRY SPRINKLER SHOWN) MINIMUM EXPOSED OFSRurs MDIDIUM BARREL IDLE EXPOSED LENGTH BARREL MSEE ABOVE) RSEE L ABOVE/ MOE fSIDE FACE ,i .....::.•::::::'::.'.: :. 1 rooSPR66UFR FACE MY SPRIAOER ..::::: :: ::.. . .1 r Al EED AREA OEATED AREA) , •'•�,:.::::•••••1 (BATED AKA) 1. .. ..•.•...•... ...........1 iIN MI III >, VET PIPE 1 ..::•:::.:::::.: > 1 VET PIPE lb:.:.:.:.:. :;::: PEAL 1::::::::::::::::: .::::::,::::::::1 % ... . .......... 1 (PROTECTED AREA OFCKTTE 400FUMING E RAS f400JPI0 MUTATED (RECpMENOEy) OR COOLER STRUCTURE OR EXTERIOR FRAM 01NMIA Fig. 1 3 . Technical Data: Maintenance K Factor Temperature Sprinkler Model DH56 Quick Response Dry Sprinklers should be Thread Rating Maximum Identification inspected quarterly and the sprinkler system maintained in Size SWC Ambient Number accordance with NFPA 25. Do not remove the factorya p- us Metric Sprinkler Cover Temperature (SIN) plied thermally sensitive wax fillet between the bulb support- 155°F 135°F 100°F ing cup and the wrenching boss. Do not replace this wax with (68°C) (57°C) (38°C) a substitute substance. An alternate substance may interfere 5.6 80 1" 175°F 165°F 150°F RA1664 with proper operation of the sprinkler. Do not clean sprinklers (79°C) (74°C) (66°C) with soap and water, ammonia or any other cleaning fluids. 200°F 165°F 150°F Remove dust by using a soft brush or gentle vacuuming. Re- (93°C) (74°C) (66°C) move any sprinkler which has been painted(other than factory applied)or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of dam- Coverage Area aged or operated sprinklers. Prior to installation, sprinklers Maximum Coverage Flow Rate pressure should be maintained in their original cartons and packaging Area Width x Length psi bar ft x n(m x m) gpm(Umin) ( ) until used to minimize the potential for damage to sprinklers 28 x 8(8,5 x 2,4) 23(87,1) 16.9(1,2) that would cause improper operation or non-operation. 28 x 10(8,5 x 3) 28(106) 25(1,7) Model DH56 Quick Response Approval Type: Extended Coverage Horizontal • Quick Response, Extended Coverage. Sidewall Dry Sprinkler Specification • Approved for installation in accordance with NFPA 13 Sprinklers shall be a [quick response- cULus Listed] ex- for light hazard occupancies. tended coverage horizontal sidewall sprinkler for light hazard occupancies. Sprinklers to be of bronze frame construction Step 1 with a special deflector capable of providing a discharge over 4L111111"ii „ a coverage area of 28 ft. (8,5m) wide, and 10 ft. (3m) long gal horizontal throw.Water seal assembly shall consist of a Teflon- coated Belleville spring washer. Installation shall permit sprin- • kler deflectors to be positioned 4" (102mm)to 12" (305mm) below the ceiling. Sprinklers shall have a nominal K-factor Step 2 of 5.6(80), and 1" NPT thread. Sprinkler temperature rating I shall be [155°F(68° C)] and [200°F(93°C)]. Rated working pressure shall be 250 psi (17.2 bar). Standard finish: [whit e][chrome][bronze][Special finish-specify]. Quick response t extended coverage horizontal sidewall dry sprinklers shall be Reliable Model DH56, SIN RA1664(Bulletin 016). Step 3 For recessed EC horizontal sidewall sprinklers: Replace "horizontal sidewall"with'recessed horizontal sidewall." Add: f (1) Recessed escutcheon assembly shall be a two-piece es -. t' cutcheon of push on and thread off design with 1/2" (13mm) .4____ adjustment.Standard finish shall be chrome,white and brass. Quick response recessed horizontal sidewall sprinklers shall Fig.2-XL02 Wrench be Reliable Model DH56, SIN RA1664(Bulletin 016). For concealed EC horizontal sidewall sprinklers: Replace "horizontal sidewall" with "concealed horizontal sidewall." Add: Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a 1" (13mm) cover plate adjust- / ment. Cover plate temperature rating shall be 135°F(57°C) r/ for 155°F (68°C) dry sprinkler and 165°F (74°C) for 200°F (93°C) dry sprinkler. A bulb protector shall be provided and factory installed inside the sprinkler cup to protect the glass bulb from damage, which could occur during construction • before the cover plate is installed.Standard cover plate finish: Fig.3-F3Wrench [white] [Custom Color- specify]. Quick response extended coverage concealed horizontal sidewall dry sprinklers shall be Reliable Model DH56, SIN RA1664(Bulletin 016). 4. DH56 HSW DRY SPRINKLER - 1 1/2- [38.10mm] — Total Adjustment I—_ ___________ _____—__7 _ 7 Ceiling I - r_______—__—__ TM L.-L Ln 1 1/4" [31.75mm] 4" [101.60mm] Min. Escutcheon Adjustment 12" [304.80mm] Max. 1/4" [6.35mm] System Tee �~11 ` [ Escutcheon Adjustment 1 15/16" ,�_ 1" NPT ` ` [53.18mm] ram 1 1 n 1 `ifltll�llll�lIIIII III ' I") 1 ,v 3�. Dia. �--m` —;�,ij�lllllllllll'I -%� � [76.20mm] f ll) '� .` Il 2 1/8" Dia. 13 , [53.96mm] I Hole in Wall t,._J -.II_1/4" [6.35mm] Protrusion Sprinkler Can - "A" Dimension Adjustment Nominal Position Range - 1/4" [-6.35mm] of Escutcheon 016Fc04 + 1 1/4 [4-31.75mm] Available "A" Dim. is 2" to 48" (51mm to 1219mm) in 1/4" (6mm) increments Note: The Sprinkler Can protrudes v4"when escutcheon is in nominal position. Escutcheon adjustment provides - 1/4"(-6mm) to +1v4" (+32mm) "A" dimension adjustment range. Fig. 4 DH56 HSW DRY SPRINKLER 1" [25.4mm] - Total Adjustment T Ceiling 1' 1/2" [12.7mm] .-.. ...-- Escutcheon Adjustment 4" [101.60mm] Min. ['' 12" [304.80mm] Max. 1/2" [12.7mm] —_ Escutcheon Adjustment r 1 15/16" System Tee 3� [53.18mm] �- C\1 1" NPT 1 i %/%� � 2-13/64" _ / 2" —4-ur-H-- \[ - ----- -- - - — [55.88mm] [88.9mm] u" n Dia. N Escutcheon Dia. f--1J 2 1/2" Dia. [63.5mm] ' 1-1/4" [31.75mm] Nominal Hole in Wall 1_0 Protrusion Sprinkler Can "A" Dimensio Escutcheon Adjustment Nominal Position oleFcos4 Range + 1/2" [+12.7mm] of Escutcheon - 1/2" [-12.7mm] Note: The Sprinkler Can protrudes 11/4" when escutcheon is in nominal position. Escutcheon adjustment pro- vides - 1/2" (-12.7mm) to +1/2" (+12.7mm) "A" dimension adjustment range. Fig. 5 l' 5. - DH56 HSW RECESSED DRY SPRINKLER Ceiling Escutcheon F 1 1/2 [38.1 mm] 4" [101.6mm]Min. System Tee Cup 12" [304.8mm]Maz.'* 1" NPT i ```- i IIIINIIIII14 _-mg (_1hv 3 7/32" Dia. �:__I�IljllllllIlIII IMM-■ I/ogle [81.8mm] ilM Ill 2 5/8" Dia. i [ e. n Hole in Wall Nominol Position ol 2 9/32" Dia. '-/// of Escutcheon [57.94mm] .... - ----1/4" Dia. Escutcheon Adjustment "A" Dimension _.. 1/2" Dia. [12.7mm] Adjustment Ronge i Escutcheon Adjustment O16EGO6 ±1/4" [±6.35mm] 1/4" Dia. Escutcheon Adjustment Available "A" Dim. is 3-1/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments Note: Do not install the Model DH56 Dry EC Horizontal Recessed Sidewall Sprinkler in walls which have positive pressure in their side space. Fig. 6 DH56 HSW CONCEALED DRY SPRINKLER Hole in Wall Ceiling I I I I PUSH ON COVER,,IEN /URN TO ADJUST um. 8m-n nr IIb4 MANS/WALL. <'ro rz' LL �r rvr i�II [race ro wxe) II I �litiliina \ lllllllii�l� � I Ia 1.il -+ /)_:..,,., J J/fr fax ry �1 I J �` i ' - ���Ems -- , eV awarER ras I, k IIPel . :r .r,2.-0- (*URN n-Amen) *el M.aM, of arPANA--,-. 0 f6F007A OMENSAAVS x,612ICYCI$ARE IN M!LLatrtnb AO 'PW•4AWAnWR MMIrpE Available "A" Dim. is 3-1/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments Fig. 7 6. *CAUTION* DO NOT INSTALL MODEL F3, MODEL F3QR OR MODEL DH56 HSW DRY SPRINKLERS INTO CPVC ADAPTER FITTINGS OR TEES THAT HAVE AN INTERNAL OBSTRUCTION. THIS WILL DAMAGE THE SPRINKLER AND/OR THE FITTING. CPVC ADAPTER FITTINGS AND TEES WITH INTERNAL OBSTRUCTIONS ARE ALSO COMMONLY FOUND DURING THE RETROFITTING PROCESS OF RELIABLE'S OLDER MODEL G3 DRY SPRINKLERS. INTERNAL NO INTERNAL OBSTRUCTION R OBSTRUCTION �� � FEMALE q$ FEMALE �� r• PIPE %: �l PIPE /` � THREAD THREAD. HREAD t INCORRECT CORRECT CPVC ADAPTER CPVC ADAPTER FITTING OR TEE FITTING OR TEE 1 SHORTER LONGER INLET 1 - INLET _ MALE MALE PIPE PIPE THREAD THREAD MODEL F3-PL. MODEL F3QR-PL OR STANDARD MODEL DH56 HSW-PL MODEL F3, DRY SPRINKLER MODEL F3QR OR MODEL DH56 HSW DRY SPRINKLER BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION 016fg08A Fig.8 7. Ordering Information Installation Wrench Specify: Model XLO2 Sprinkler Wrench (Recessed & Concealed) 1. Sprinkler Type (select one): Model F3 Sprinkler Wrench (a)Model DH56 Dry EC HSW Note: A leak tight 1" NPT sprinkler joint can be obtained (b)Model DH56 Dry EC HSW/HB with a torque of 20-30 ft-lbs (27.1 - 40.7 N-m). Do not (c)Model DH56 Dry Recessed EC HSW/FP tighten sprinklers over maximum recommended torque. (d)Model DH56 Dry Concealed EC HSW It may cause leakage or impairment of the sprinklers. 2. Sprinkler Temperature Rating. 3. Sprinkler Finish. Escutcheon Data: 4. Cover Plate/Escutcheon Finish. FP cup/escutcheon assembly- 1/2"(13mm) adjustment 5. Length: "A" Dimension (face of tee to face of ceiling or Finishes (1) wall) in (6mm) increments. Standard Finishes t't Notes: Sprinkler Escutcheon Cover Plate 1. The "A" dimension is based on a nominally gauged pipe White Polyester« Brass 13 thread "make-up" of 0.600" (15mm) per ANSI B2.1 [71/2 /Chrome/Bronze White/Chrome White threads approximately]. 2. All platings and paintings are decorative and intended for t') Other colors and finishes are available. Consult factory for details. interior use. (2)cULus Listed as Corrosion Resistant Sprinkler in standard Black or White. UL Listing Category (2)Not available for HB escutcheons. Sprinklers, Automatic and Open. Note:Paint or any other coatings applied over the factory finish will void Quick Response Sprinklers. all approvals and warranties. 16' [4.9m] Minimum Spacing 28' [8.5m] Maximum Spacing MODEL DH56 DRY SPRINKLER WALL [100mm] min.From Ceg [305mm] max.From Ceiling 28' [8.5m,1 \� \\ \\ 10' [3m] 016E CC9A Fig.9 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co.,Inc. Recycled ® (800)431-1588 Sales Offices Paper Re l i b' (800)848-6051 Sales Fax Revision lines indicate updated or new data. (914)829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.01/13 PM 9999970308 Bulletin 157 Rev.— ® Model F3QR lil Reliable Quick Response Dry Sprinklers 7, Features m 1 . The Model F3QR sprinkler utilizes Belleville Spring ; : ,•,, Closure TechnologyReliable is the first in the , .•k t'• ' c: • ':' industry to produce a Quick Response Dry �•:•'• . : c ., Concealed sprinkler utilizing this technology. ' 2. Styles available >;.f • •. • Pendent ' . ;.-ir . . 1 • Recessed Pendent • Concealed I • Horizontal Sidewall . • _ • Recessed Horizontal Sidewall ti 3. 11" (38mm) escutcheon adjustment on pendent Concealed sprinkler. ; - - 4. 1/2' (13mm) escutcheon adjustrtient on recessed '-., : = sprinkler with push-on/ thread off FP Model - .` . . , Escutcheon ring. 5. /" (9.5mm)cover plate adjustment on concealed sprinkler with push-on/thread-off CCP Cover Plate. . 6. Attractive appearance. Employs 3mm frangible - — _ -,. - • glass bulb and galvanized nipple. 7. Lengths available to accommodate installation - . dimensions from 2'-to-48"(51mm-to-1219mm), Recessed Pendent in '/4" (6mm) increments. 8. Available in a variety of plated and painted finishes. _.�X j U.S. Patent Numbers 5,775,431 and 5,967,240. Approvals ` 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) 7 n ) Sprinkler - Style Response System Type Hazard ' r Pendent -- --- Recessed Pendent CCP Concealed Wet Pipe Light Pendent (R5714) Quick Dry Pipe Ordinary Horizontal Sidewall All Preaction Recessed Horizontal Sidewall (R5734) 2. Certified by FM Approvals Style Response Sprinkler Hazard d System Type light 44.. 4' . . . Pendent Wet Pipe, Ordinary, i t (R5714) Quick Sing Interlock Groups Preaction 1&2 iir • Horizontal Sidewall Wet Pipe, (R5734) Quick Single Interlock Light Preaction ' 3. NYC MEA 258-93-E Horizontal Sidewall The Reliable Automatic Sprinkler Co.,Inc., 525 North MacQuesten Parkway,Mount Vernon,New York 10552 - Model F3QR Dry Pendent Sprinkler "A"Dim. 2"to 48"(51 mm to 1219mm)in Ya"(6rm)increments Finishes'') Inlet Protrusion Elevated Above Inside Pipe Sprinkler Escutcheon ___ e_� ____!____ - Bronze Brass ly F 7 I __ Chrome Plated Chrome Platedl I a==- --' E-- lik===j White Painted` White �-�•�•4-�� L 'ti ni r System Tee Other finishes and colors are available on special order. � Consult factory for details. i , 1.1 ''White painted sprinklers will have chrome plated cans. 2 1/6" No NPT [ m ] I. "A"Dimension Hole in Cemiling Adjustment Range I/4"[+6.4mm] 1 43 64"No. Standard Temperature Ratings / -1 1/4'[-31.8mm] [47.5mm] II I 1 1/2" m] Sprinkler Sprinkler Con Total Adjustment Temperature Max Bulb :WI l 1 1/4"[31.8mm] Classification Rating Ambient Temp. Color E "'� ."[6.4mm] Escutcheon ---- r3culcheon Ordinary 135°F (57°C) 100°F (38°C) Orange `ceilln9 c ` AijIsimen` Ordinary 155°F (68°C) 100°F (38°C) Red -AGMi `� - Intermediate 200°F (93°C) 150°F (66°C) Green ,High 286°F (141°C) 225°F (107°C) Blue Nominol Position i`is1 i13m6m] of Escutcheon •Ir� 1/4"[6.4mm] Protnusion 3"No. (76.2mm] lencm-C Sprinkler Guard: Model C-2 Sprinkler Installation Wrench Note: The sprinkler Can protrudes 1/4"when escutcheon is Model G3 Sprinkler Wrench in nominal position. Escutcheon adjustment pro- Sprinkler Identification Number (SIN): R5714 vides+1/4"(+6mm)to -11/4'I(-32mm)"A"dimension adjustment range. Model F3QR Dry Recessed Pendent Sprinkler "A"Dim. 31/2'to48"(891rn1 to 1219mm)in 1/4"(6mm)incrnrlents }} (�) Inlet Protrusion Elevated ____•r—�---T--- r—-115F--=(,II Finishes Above Inside Pipe flM I l 4l Sprinkler Escutcheon I a -_J as i_--i —_; Bronze Brass ) c Chrome Plated Chrome Plated System Tee White Painted White i 01 Other finishes and colors are available on special order. Consult 2 1/2" Die. III�II� 1" NPT factory for details.Cup remains unfinished.Only the escutcheon [63.50mm] 1111 will contain desired finish. "A" Dimension Hole in CeiI ng Adjustment Range Standard Temperature Ratings ±6 5mm 2[58.3419/6 Dio. p g [ ] 58.34mm Sprinkler Temperature Max. Bulb Nominal Position Sprinkler Classification Rating Ambient Temp. Color of Escutcheon Cup Assembly Ordinary 135°F (57°C) 100°F (38°C) Orange II Escutcheon Ordinary 155°F (68°C) 100°F (38°C) Red 41[Ceiling I (r„ Intermediate 200°F (93°C) 150°F (66°C) Green il!�JJI Ceiling High* 286°F (141°C) 225°F (107°C) Blue 1/4" [6.35mmj - Escutcheon Adjustment 1/4" [6.35mm] 3 7/32" Dio. Listed and Certified only by cULus Escutcheon Adjustment [81.76mm] 1/2" [12.7mm] — Totol Adjustment 157TG02-C Sprinkler Installation Wrench Model G3 R/C Sprinkler Wrench Note: Do not install the Model F3QR Dry Pendent Recessed Sprinkler in ceilings which have positive Sprinkler Identification Number (SIN): R5714 pressure in the space above. 2. Model F3QR Dry Pendent Concealed Sprinkler j"A"Dim. 3X"to 48"(89mm to 1219rrrn)in 1/4"(6mm) increments Inlet Protrusion Elevated (1) (2) Above Inside Pipe CCP Cover Plate Finishes ___ ____ _ __ Standard Finishes Special Application Finishes r Chrome Plated Bright Brass Plated ;;--_a --1 E-- i --= " White Black Plated --' i-z Black Paint I. — Off White System Tee mob Satin Chrome '' Utilizes the y2 cover plate with%"total adjustment. 1" NPr '2 Other finishes and colors are available on special order. Consult factory for details. 2 1/2" Dia. [6.35mm] In "A" Dimension Hole in Ceiling Standard Temperature Ratings Adjustment Range 2 19/64" Dia Sprinkler [i4.76mrn] [58.34mm] Temperature Cover Plate Max. Classification Rating Temp.Rating Ambient Temp. Nominal Position sprinkler 0 0 0 0 of Coverplate Cup Assembly Ordinary 135 F (57 C) 135°F (57°C) 100°F (38°C) Ordinary 155°F (68°C) 135°F (57°C) 100°F (38°C) _ _�i1 Coverplate Intermediate 200°F (93°C) 165°F (74°C) 150°F (66°C) Assembly i Celing I i�� High* 286°F ( 41°C) 165°F (74°C) 150°F (66°C -- `Idyl,' Ceili;- - - Coverplote Adjustment "'Listed and Certified only by cULus. Note: Do not install the Model F3QR Dry Pendent Sprinkler Installation Wrench: Concealed Sprinkler in ceilings which have Model G3 R/C Sprinkler Wrench positive pressure in the space above. Sprinkler Identification Number (SIN): R5714 Model F3QR Dry Horizontal Sidewall Sprinkler . "A"Dim. 2'to48'(51mm to 1219mm)in 1/4"(6mm)increments 1 (1) 1 1/2" [38.10mm] lI` Finishes Totol Adjustment r-I` r Ceiling —' Sprinkler Escutcheon I r i o r--------------- f Bronze Brass 3' [107.60mm]] Mn. Chrome Plated Chrome Plated /r (31.75 mm l ] [ ] 4 12" [304.80mm] Max 1 White Painted`' White Escutcheon Adjustment (n 1 Fs— 1/4" (6.35mm] Other finishes and colors are available on special order. system Tee �~ Escutcheon Adjustment Consult factory for details. NPr . �, 1 F ° • t White painted sprinklers will have chrome plated can. ]_ r, • y Is Ir 2 3/32" I (53.1Bmm] sfa,; I4 • II 3. Standard Temperature Ratings -;4---+ '--; - [76. 0mm] } t Sprinkler `-1"-- �,-- _ __ Temperature Max Bulb 2 1/s' Dia. , Classification Rating Ambient Temp. Color [53.98mm] Hole in Wall L' �-1/4" [6.35mm] Ordinary 135°F (57°C) 100°F (38°C) Orange Sprinkler Con Protrusion Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate 200°F (93°C) 150°F (66°C) Green "A" Dimension Nominal Position 0 0 0 o Adjustment of Escutcheon High 286 F (141 C) 225 F (107 C) Blue „ems_c Range + 1/4"tnent [+6.}Smm] Sprinkler Installation Wrench: Note: The sprinkler Can protrudes 1/4"when escutcheon is in nominal position. Escutcheon adjustment pro- Model G3 Sprinkler Wrench vides+1/4"(+6mm)to -11/4"(-32mm)"A" dimension • Sprinkler Identification Number (SIN): R5734 adjustment range. 3. Model F3QR Dry Horizontal Recessed Sidewall Sprinkler "A"Dim. 31/2'to 48"(89rrrn lo 1219mm)rn 1/a'(6mm) increments • r..—c°iiinq'i Finishese" Sprinkler Escutcheon Escutcheon r 113/32 [3s.lmm] Bronze Brass n 4 101.6mm]Min. Chrome Plated Chrome Plated -System Tee coo i 12'43oA.&nm]Ibr.* White Painted White I \ NOT r "'Other finishes and colors are available on special order. Consult 7 .--� I`I M__ + factory for details.Cup remains unfinished."See page 2" T I ` 'J I IIIIII�I ���1•• 'i "+ '■III II 3 ry3T Di.. ILI Ii I [B1Amm] 2 1/2'Oio. - �� [63.Smm] Hale inWall 13. 2 19/U"01a. [--.] [6B.3mm] Standard Temperature Ratings /2 r127mn, 'A'Dimension F Escutcheon Adjustment p 9 Adjuatmenl R°nge 137Fcoe +1/2'-0 Sprinkler [+121mm -o] Temperature Max. Bulb Classification Rating Ambient Temp. Color *•FOR FACTORY MUTUAL(FM) •a"- 6'FOR UNDERWRITERS LABORATORIES(UL) Ordinary 135°F (57°C) 100°F (38°C) Orange Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate 200°F (93°C) 150°F (66°C) Green High* 286°F (141°C) 225°F (107°C) Blue Notes:Do not install the Model F3QR Dry Horizontal • Listed and Certified only by cULus. Recessed Sidewall Sprinkler in walls which have positive pressure in their side space. • Listed by cULus for Quick Response.Approved Sprinkler Installation Wrench: by FM for Standard Response. Model G3 R/C Sprinkler Wrench • Recessed Horizontal sidewall sprinklers are listed p with cULus for installation of min.4'(100mm)-to- Sprinkler Identification Number (SIN): R5734 max.6"(150mm)below ceiling and approved by FM for installation of min.4"(100mm)-to-max. 12"(300mm)below ceiling. Technical Data: Ordering Information Orifice Size: 1/2" (15mm) Specify: Thread Size: 1" NPT per ANSI B2.1 Type Sprinkler 1. T e(select one): Pressure: 175 psi (12 bar) Nominal K Factor- US/(Metric): 5.6/(80) (a)Model F3QR Dry Pendent Product Description (b) Model F3QR Dry Recessed Pendent Reliable Model F3QR Dry Sprinklers are quick response (c)Model F3QR Dry Concealed Pendent sprinklers utilizing a durable 3mm frangible glass bulb. This (d) Model F3QR Dry Horizontal Sidewall quick response enables these sprinklers to apply water to a (e)Model F3QR Dry Recessed Horizontal Sidewall fire much sooner than standard response sprinklers of the 2. Sprinkler Temperature Rating. similar temperature rating. 3. Sprinkler Finish. Model F3QR Dry Sprinklers are intended for use in enclosed dry and preaction systems and in enclosed areas subjected 4. Cover Plate/Escutcheon Finish. to freezing temperatures, such as freezers and unheated 5. Length: portions inside buildings. "A" Dimension(face of tee to face of ceiling or wall) Environments wherein dry sprinklers are employed can be in 14" (6mm) increments. corrosive.For this reason,Model F3 Sprinklers have a special F3QR Dr y d Moe wax fillet placed in the gap between the cup that supports the 6. Pendent(a) is available without bulb and the wrenching boss.This wax will not interfere with sprinkler can and escutcheon. the operation of the sprinkler, and it prevents contaminants from entering the internal portion of the drop nipple.The wax Note: must not be removed. Operation 1. The "A" dimension is based on a nominally gauged pipe thread "make-up" of 0.600" (15mm) per ANSI The glass bulb consists of an accurately controlled amount B2.1 [71/2 threads approximately]. of special fluid hermetically sealed inside a precisely 2. All platings and paintings are decorative and manufactured glass capsule. This glass bulb is specially intended for interior use. constructed to provide fast thermal response. When the temperature increases sufficiently, due to a fire, the bulb shatters allowing operating parts to clear the waterway. This • enables the inlet seal to release air or water and subsequently, cause water flow over the deflector in a uniform spray pattern, controlling or extinguishing the fire. 4. General Installation Instructions the bulb supporting cup and the wrenching boss. Do not - In steel pipe, the Model F3QR Dry Sprinklers must be replace this wax with a substitute substance. An Alternate installed only in standard (ANSI B 16.3 class 150 and substance may interfere with proper operation of the ANSI B 16.4 class 125) pipe tees even at branch line sprinkler. Do not clean sprinklers with soap and water, ends. For these and CPVC* Tees, the dry sprinkler ammonia or any other cleaning fluids. Remove dust by should be installed and confirmed to have appropriate using a soft brush or gently vacuuming. Remove any protrusion into the tee in accordance with the figures on sprinkler which has been painted (other than factory pages 2 & 3. Dry sprinklers must not be installed into applied) or damaged in any way. A stock of spare elbows and into pipe couplings located on drop nipples sprinklers should be maintained to allow quick to the sprinklers. The "A' dimension of a dry sprinkler, replacement of damaged or operated sprinklers. Prior to which extends into a freezer from a wet pipe system, installation, sprinklers should be maintained in the original should be selected to provide at least 14" (356mm) cartons and packaging until used to minimize the potential between the freezer's outside wall or ceiling and the wet for damage to sprinklers that would cause improper pipe line. When the temperature inside the freezer will be operation or non-operation. below-30°F (-35°C), increase the 14"to 20" (509mm). 1. Cut the specified size hole (see illustrations) for the sprinkler in the ceiling directly in line with the tee. *Spears CPVC sprinkler adapter tees(with steel thread 2. Apply pipe joint compound to the 1" (25mm) pipe insert) can only be used with horizontal sidewall threads and install sprinkler using the Model G3 or sprinklers which do not require protrusion into tees to G3 R/C Sprinkler Wrench as specified. prevent ice or debris blockage of sprinkler inlets. These 3.Install the push-on escutcheon or coverplate. CPVC tees d not permit sufficient sprinkler inlet P protrusion as required for pendent installation. Note: Installation of the Model F3QR Sprinklers in copper pipe systems is not recommended, as this may reduce the life expectancy of the sprinklers. Model F3QR Concealed and Recessed Installation Instructions • The Model G3 RJC wrench(Fig. 1)is designed to locate on the wrenching pads of the recessed sprinkler while centering in the cup. A standard '/2" drive ratchet may be used to drive this wrench. Figures 1 and 2 show sequentially the insertion of the wrench.First the wrench, with its jaws above the sprinkler deflector, is moved laterally until centered with the cup. Then raise the wrench inside of the cup until its jaws engage the sprinkler's square wrenching pads (Fig. 3). To remove the wrench,follow this procedure in reverse order. Care should be taken to avoid striking the deflector, with the wrench. • Model G3 Wrench (Fig. 4) is used for installation of Pendent and Horizontal Sidewall sprinklers. • Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Maintenance The Model F3QR Quick Response Dry Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not remove the factory applied thermally sensitive wax fillet between 5. I ~+ t A 71_ E.:- 3 ''...:-....„..........i'll- v. 4 Fig. 1 - G3 R/C Wrench Fig. 2 - G3 R/C Wrench Fig. 3 - G3 R/C Wrench ',LI 41111110 •N • y r, 1 v Fig. 4-G3 Wrench The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured b The Reliable Automatic Sprinkler Co.,Inc. Recycled i ' iabI (800) 84 -6051 Sales Offices Paper (800) 848 6051 Sales Fax (914) 668-3470 Corporate Offices Revision lines indicate updated or new data www,reliablesprinkler corn Internet Address E.G.Printed in USA 6/05 P/N9999970175 Bulletin 110 Rev.S Model GAutomatic SprinklersRehabia Spray Upright, Spray Pendent And Conventional Product Description The Reliable Model G Automatic Sprinkler utilizes the center strut solder in compression principle of t e construction. The fusible alloy is captured in the cylinder of the solder capsule by a stainless steel ball. When the fusible alloy melts, the ball moves into the r 1 cylinder allowing the cylinder to fall away from the ,..:•" '► sprinkler. When this happens, the lever is released to :� 1 j spring free from the sprinkler so that all of the operating ;so k IV IV parts clear from the waterway allowing the deflector to "- distribute the discharging water. / _ ,, - Except for the parts in the cylinder as mentioned / above, the sprinkler components are made from / Upright Pendent copper based alloys for maximum corrosion protection. Lead plated, wax coated or wax over lead plated sprinklers are available for specially severe environments. Chrome plated sprinklers are available for decorative purposes. , All sprinklers are individually hydrostatically tested. 4 All sprinklers are identified as to their fusing point by } markings that appear on several of the operating parts "' and by an identifying color that appears on the frame. . . . 0 Sprinkler Types • Standard Upright - This deflector configuration is Small Orifice Upright Conventional normally used with exposed piping installations.Water is distributed laterally and downward in a wide pattern approximating a hemisphere which is completely and uniformly filled with water in the form of small drops or ' spray. Standard Pendent - This deflector configuration is Application and Installation normally used where the space above the piping is Standard sprinklers are used in fixed fire protection limited or where a concealed piping installation is systems:Wet, Dry, Deluge or Preaction. Care must be employed. The discharge characteristics of the exercised that the orifice sizes, temperature ratings, standard pendent are virtually identical to the deflector styles and sprinkler spacings are in standard upright as described above. accordance with the latest published standards of the National Fire Protection Association or the approving Large and Small Orifice—By varying the orifice size, authority having jurisdiction. a large or small orifice sprinkler is created that will The sprinklers must be installed with the Reliable distribute as much as 40% more water or 65% less Model D Sprinkler Wrench. Any other type of wrench water than the normal '/2" (15mm) orifice sprinkler. may damage the sprinkler. The approvals or listings of Reliable Automatic Conventional—This deflector configuration is used Sprinklers by major approving organizations are primarily in those countries where the LPC installation shown in the tabulated list provided on the back of this rules have precedence. The sprinkler is designed to bulletin. distribute a portion of its water discharge upward against the ceiling with the balance downward. It may be installed in either the upright or the pendent position. Sprinklers with conventional deflectors are available with orifice sizes corresponding to light, "Patent No.4,440,234 ordinary and extra-high hazard installations. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 . Technical Data "K" Factor Sprinkler Identification Sprinkler Number(SIN) Sprinkler Type US Metric Height Approvals SSU SSP Standard-Upright(SSU)and Pendent(SSP) Deflectors Marked to Indicate Position }2"(15 mm)Standard Orifice with}2"NPT(RX)Thread 5.62 81.0 2 f" (73 mm) 1,2,3,4,5,6,7 R1025 R1015 /,e"(11 mm)Small Orifice with X"NPT(R'/)Thread 4.24 61.0 2 f" (73 mm) 1,3,7 R1023 R1013 X,"(10 mm)Small Orifice with}2"NPT(RJ2)Thread 2.82 40.6 2'/e" (73 mm) 1,2,3,7 R1021 R1011 Ye"(8 mm)Small Orifice with y"NPT(R/)Thread 1.98 28.5 2'/a" (73 mm) 1,3,7 R1022 R1012 '%2'(20 mm)Large Orifice with}2"NPT(Ry)Thread 7.96 114.7 2'/e" (73 mm) 1,2,3,7 R1026 R1016 %"(20 mm)Large Orifice with X"NPT(R/)Thread 8.20 118.2 21Y,6" (75 mm) 1,2,3,7 R1027 R1017 20 mm XHH with 20 mm Thread 8.20 118.2 75.4 mm 4,5,6 R1027 R1017 10 mm XLH with 10 mm Thread 4.10 59.1 73 mm 4,5,6 R1024 R1014 Conventional—Installed in Upright or Pendent Position 10mm XLH with l Omm Thread 4.10 59.1 73 mm 5 R1074 15mm Standard Orifice with(Ry) Thread 5.62 81.0 73 mm 4,5,6 R1075 20mm XHH with(R%)Thread 8.20 118.2 75.4 mm 4,5 R1077 Temperature Ratings Maintenance Maximum Model G Sprinklers should be inspected quarterly and the Sprinkler Ambient sprinkler system maintained in accordance with NFPA 25. Do Rating Temperature Frame co not clean sprinklers with soap and water,ammonia or any other Classification °F °C °F °C Color cleaning fluids. Remove any sprinkler that has been painted Ordinary 135 57 100 38 Black (other than factory applied)or damaged in any way.A stock of Ordinary 165 74 100 38 Uncolored spare sprinklers should be maintained to allow quick replace- Intermediate 212 100 150 66 White ment of damaged or operated sprinklers. Prior to installation, High 286 141 225 107 Blue sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to (1)Frame color does not apply to painted or plated sprinklers sprinklers that would cause improper operation or -Use sprinkler rating as identified on operating parts. non-operation. Use only the Model D Sprinkler Wrench for sprinkler removal and installation.Any other type of wrench may damage the sprinkler. Finishes(1) Standard Finishes Approval Organizations Bronze —All Temperature Ratings 1. Underwriters Laboratories, Inc. Chrom —All Temperature Ratings 2. Factory Mutual Research Corporation White(4) —All Temperature Ratings 3. Underwriters' Laboratories of Canada Only Frame and Deflector are Painted 4. Loss Prevention Council Special Application Finishes 5. Pleniere Assemblee Bright Brass Plated —Only frame,deflector and cap are plated. 135°F(57°C), 165°F 6. VdS S. BS&A No. 58 -gg (74°C),212°F(100°C)Temp.Rating. 7. N.Y.C. MEA E-75 SA or N.Y.C. MEA 258-93-E Black Plated -Only frame,deflector and cap are plated.All Temp.Ratings. Polyester Coated(2) —Only frame and deflector are coated. Lead Plated —165°F(74°C),212°F(100°C)and 286°F(141°C)Temp.Ratings. Ordering Information Wax-Coated(3) —165°F(74°C)Clear Wax,212°F(100°C) Brown Wax. Specify Wax-Coated Over 1. Model G Lead Plated(3) —165°F(74°C)Clear Wax,212°F(100°C) Brown Wax. 2. Deflector • Upright (1) Other colors and finishes are available.Consult factory for details. •Pendent (2) UL listed and NYC MEA Approved only. •Conventional (3) 212°F(100°C)brown wax may be used on 286°F(141°C) 3. Nominal Orifice sprinklers when maximum ambient temperatures do not exceed 150°F 4. Inlet Thread (66°C).UL Listed, FM Approved.NYC MEA 258-93-E. 5. Temperature Rating I 6. Finish The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured by ' The Reliable Automatic Sprinkler Co.,Inc. fle• (800)431-1588 Sales Offices ® ReryNed (800)848-6051 Sales Fax (914)829-2042 Corporate Offices Revision lines indicate updated or new dPaper ata. www.reliablesprinkler.com Internet Address EG.Printed in U.S.A. 11,04 PM 9999970005 ti, State Pipe & Supply, Inc.A SeAH,,,,, Y , yg 11111/11 IIllil iiia. =_,,I.:A40.i!';rl l l.-t i,;+.i lrii 3. rli.11,.,la:.i Sr..,+it ,ia, Products ► I Technical Specs:A53 Seamless&Welded Standard Pipe ►'• •.. �% Welded&Seamless ,-, A i 'l Grade BIAPI C+% Back ..i) Print Page Domestic-A53FCW- General Description =1♦.� �' &Import-A53A ER.W. Specification A53 covers Seamless and Welded, black and hot-dipped I � galvanized nominal (average) wall pipe for coiling, bending, flanging, and • Fire Sprinkler Pipe!h� _ SPS Flow Pipe '? other special purposes and is suitable for welding. - Fittings,Flanges&Valves _`At,. ASA PipeSchedules e OrnamentalTubing� Mechanical Properties - Tensile Requirements �� Services Seamless and ERW Grade A Grade B • le fbaeilits Ai, Tensile Strength, min., psi 35 48,000 60,000 Cutting (diameters) Yield Strength, min., psi 30,000 35,000 alkassw� r Grooving(cut grooving, roll grooving) rye, Threading&Beveling ,-.- Chemical Requirements ' al Seamless and ERW C max % Mn max %o P max 0/0 S max ExCES OFFESPECIAL RS! Grade A 0.25 0.95 0.05 0.045 u Grade B 0.30 1.20 0.05 0.045 SeAH Contact Sales Visit our par SHAH Steel 1 News Testing Requirements Hydrostatic Testing Steel Pipe Market News Hydrostatic inspection test pressures for plain end and threaded and A coupled pipe are specified. Hydrostatic pressure shall be maintained for I Job� lis not less than 5 seconds for all sizes of Seamless and Electric Resistance Weld Pipe. Mechanical Tests Tensile Test Transverse required on ERW for NPS 8 &larger. Flattening Test For NPS 2 and larger, STD and XS walls. (Not required for XXS pipe) Bending Test(cold) For NPS 2 and under, XS wall and under For NPS 1 1/4 and under, under XXS wall. Degree of Bend Diameter of Mandrel For Normal A53 Uses 90 12 x dia. of pipe For Close Coiling 180 8 x dia. of pipe Number of Tests Seamless and Electric Resistance Weld - Bending, flattening, tensile on one length of pipe from each lot of 500 lengths, of each pipe size. Permissible Variations Wall Thickness The minimum wall thickness at any point shall not be more than 12.5% under the nominal thickness specified. Sizes i/p'-26' Std., XS and XxS, A.N.S.I.Schedules F O R E I G N 1arCGthIL:ATION A530 through 160—Other sizes subject to inquiry. Scope Covers seamless and welded BUCK and hot-dipped galvanized nominal • (average) wall pipe for coiling, bending. flanging and other special pug,: Dozes and is suitable for welding. BUTTWELDE0 pipe is not intended for flanging (roll back operation to form flange using pipe walil. A NUFACTURE Purpose for which pipe is intended should be stated on order. Kinds of Steel 0pen•hearth Basic-oxygen - Permitted For Electric.furnace Schedule 10 & 40 Pipe Material - - Hot-Dipped • Sets standards for coating of pipe with tint inside and outside by the Galvanizing hot-dipped process. Weight of coating must not average less than 1.8 oz. • per square toot and not less than 1.6 oz. per square foot. . Permissible Variations Same as A120. . in Wall Thickness . Chemical Types a<amreoe Requirements Open.lann,Electric- pipe) L Type a(electric weld/ furnace N Suit Oareen - t C<M^esi lien—Mu% • . Vide a. F S Wade 8 O.t6 0.95 0.0$ 0.06 - 0.30 1.a0 O.OS 0.06 Type F(furnace.welaed pipe) • Opte•aearth,Electric. Cempositien_Ma[% ' Furnace Sr Cali.Omen C Mn I S 0.08 0.06 Tensile Buttwelded uurneea.eia<d) acie• 0.h.,rile oxygen • Requirements Tensile Strength min., psi Bee:emer or Elec.c.fore. • D 50,000 45,000 Yield Point min., psi 30,000 25,CC0 Seamless or Electric•WelE Steele !pats Tensile Strength min., psi 48,000 60,000 Yield Point min., psi 30,000 35.000 • - Hydrostatic Hydrostatic inspection. test pressures for plain end and threaded and Testing Coupled pipe are specified. Hydrostatic pressure shall be maintained for not less than 5 seconds fcr all sizes of seamless and electric-weld pipe. Permissible For Extra Strong and lighter wall thicknesses Variations in Plus or Minus 5% Weights per Foot For heavier than arts strong wall thicknesses Plus or Minus 30% Permissible Variations Same as A120. in Outside Diameter Mechanical Tests Tensile Test—Transverse required on EN sizes 37e" and larger. Specified Bending Test (Cold) Std. and XS•2" and under. XXS-1SY" aid under. Degree of Bend Diameter of Mandrel For Normal A53 Uses 90 12 x nom.dia.of pipe For Close Coiling 180 8 x nom.dia.of pipe Flattening Test 2Vz"and larger Std. and XS. (Not required for XXS pipe). Number of Seamless and Buttweld-8ending, flattening tensite on one length of pipe Tests Required from each lot of 500 lengths or less of a size. • Efectric•Weld—Bending and tensile on one length of pipe from each lot a' '.�. . of 500 lengths or less of a size. ' - i Electric•Weld—Flattening on both crop ends of each length_ICoil, in case s >w of multiple lengths.) ,'<. h r ; Lengths Same as A120. I.,. 's z,: :` d • (Lengths longer than single Tandem, heavier wall than XS subject to ___...jjj•••��' v negotiation,/ ra . t-. . ",i i'' • Required Markings Rolled, tamped or Stenciled i - k , �` h" •1 . :• on Each Length - Name or brand of manufacturer- `• '•-1— ' ` MY .aF -5 '' (On Tees attached to each 10 ss 8 � fit' >o. ?'xz'} 13�`- i3+ 4'eF 'Q•= Sandie in ease of Brndled Kind of pipe, that is, furnace-0uttwelde? ter-A, ieamtess 8,ete. .t► �'�_ •� s ' 1 ,>n-1 .- ►iae) . XS—for extra strong. XXS'—for double extra strop' >c"" a-` ,, „IV...? x.• <3 '_�{a 2 + y ASTM A53. gs + = • �. z• Also necessary to indicate when 6fictrie•furnace.`w"3 i=I - cif '' seer �< , • Length of pipe. or basic•ax a .•Y_%}, w.-+� ,.�': yg n steel is used. �.: w ` Y„.' General n ..• Couplings—Applied handling tight Couplings, Z.:;and:;smalter straight 1' , .v:°7,.t, y .t. Informa tion ,tapped,other sizes taper tapped.Line pipe couplings may be speuf ed. • 'f ; e• w- 'r• , ...L I..., �'- .;Thread Protection—Sam6 as specified under A320_ �.. .,,,; ti :, , r'C F 4r y +c'; .•, : End Finish (unless otherwise specified) '•:,)t. ,"Alti•N+� 4`w` + a�a '" d c • Std. or XS, or wall thicknesses less than 0.500 in.Cexcluding XXS) Plain ',<. r `� +i lv,s`a'. . fin, end berated.EW pipe may lye furnished cold expanded•,a 'I x r''- $•��aw ""' , � ti •vZ i µ: All XXS and wall.thicknesses over 0500 in"Plain end square cut .sue a • ..�k �T3R6 l-o c a-, , a ,a tyCO I Flow Tyco Fire Control Products BlazeMaster FIRE SPRINKLER PIPE & FITTINGS SUBMITTAL SHEET TYCO FIRE PRODUCTS 451 North Cannon Avenue Lansdale, Pennsylvania 19446 www.tyco-fire.com TECHNICAL SERVICES TEL: (800) 381-9312 • FAX: (800) 791-5500 E-MAIL: techserv@tycofp.com f No. 19-1.5 TD915 4-1.1.20 9/2001 0 " . Introduction Tyco Fire Products (TFP) BlazeMaster'CPVC pipe and the same time, they provide superior heat resistance and fittings are designed exclusively for use in wet pipe strength as compared to traditional CPVC and PVC piping automatic fire sprinkler systems. They are made from a materials used in the plumbing trade. Various adapters are specially developed thermoplastic compound composed of available to connect CPVC pipe to metallic piping.All female post chlorinated polyvinyl chloride (CPVC) resin and state of pipe thread adapters have brass inserts for durability. the art additives.TFP BlazeMaster"CPVC products are Grooved adapters connect directly to grooved end valves easier to install than traditional steel pipe systems, and at and metallic pipe, with flexible grooved end couplings. Technical Data Sizes: 1/4"-3" Manufacture Source: U.S.A. Maximum Working Pressure: 175 psi Material: Approvals: UL, FM, CUL, NSF, Dade County, LPCB, Pipe: ASTM F442, SDR 13.5 MEA, and the City of Los Angeles Fittings: ASTM F438 (Sch. 40) and Note: See current TFP BlazeMaster Installation Instructions and ASTM F439 (Sch. 80) Technical Manual,for exact listing/approval information Color: Orange Pipe Nom.Pipe Size Avg.O.D. Inches Avg.I.D.Inches Wt.Lbs./Ft. Wt.H2O filled Pipe Lbs./Ft. Ft.of Pipe per Lift Wt.per Lift Lbs. 3/4" 1.050 0.874 0.17 0.43 7875 1413 1" 1.315 1.101 0.26 0.67 5040 1320 11/4" 1.660 1.394 0.42 1.07 2835 1191 11/4" 1.900 1.598 0.55 1.40 2205 1136 2" 2.375 2.003 0.86 2.20 1260 1063 21/2' 2.875 2.423 1.26 3.22 1215 1531 3" 3.500 2.952 1.87 4.79 720 1344 Fittings To JIio 45° Elbow Reducing _. 90° Elbow = 90° Elbow T/0' T+ Part No. Size Sch. T/O Wt. Part T/O Wt. Part No. Size Sch. T/O Wt. 80050 3/4' 40 3/6' 0.08 lb. No. Size Sch. 1 2 lb. 80025 '/a' 40 3/16" 0.09 lb. 80051 1" 40 '/3" 0.11 lb. 80032 1" x 3/4" 40 11/16" 13,,6' 0.16 80026 1" 40 /n" 0.14 lb. 80052 1'/4" 40 3/4" 0.20 lb. 80027 11/4" 40 '/a' 0.21 lb. 80053 11/4' 80 1/46" 0.31 lb. 80028 11/2" 80 11/s' 0.40 lb. 80054 2" 80 3/4' 0.56 lb. 80029 2" 80 1'/d' 0.79 lb. 80055 2'/2" 80 3/4" 0.89 lb. 80030 2'/2" 80 11/4" 1.14 lb. 80056 3" 80 1" 1.19 lb. 80031 3" 80 113/16" 1.82 lb. i Tee ------ -- " Reducing latm Cross CrossIIIMII- I/O T/O T/O' JUT T. - �7 rio' 1.11111 r,ro' 170 1111111 T/O Part No. Size Sch. T/O Wt. Part T/O Wt. Part No. Size Sch. T/O Wt. 80000 3/4" 40 6/a' 0.11 lb. No. Size Sch. 1 2 lb. 80009 1/4" 40 9/16" 0.13 lb. 80001 1" 40 3/4" 0.19 lb. 80015 1"x 3/4" 40 "/16" "/16' 0.28 80010 1" 40 /16" 0.23 lb. 80002 1'/4" 40 '/6' 0.26 lb. 80011 11/4" 40 1s/16" 0.34 lb. 80003 1'h" 80 1" 0.51 lb. 80012 11/4' 80 11/46" 0.67 lb. " 80004 2" 80 1 /8" 0.90 lb. 80013 2" 80 13/e" 1.00 lb. 80005 2'/2' 80 1V16" 1.59 lb. 80014 2'/3" 80 13/,6' 1.91 lb. 80006 3" 80 1"/16" 2.41 lb. 80008 3" 80 111/46" 2.89 lb. 9Po - �T70 - n Reducer Coupling Cap - r-- -- Bushing Part No. Size Sch. T/O Wt. Part No. Size Sch. T/O Wt. Part No. Size Sch. T/O Wt. 80200 1" x 3/4" 40 716' 0.04 lb. 80075 3/4' 40 '/e" 0.07 lb. 80100 3/,." 40 1/46" 0.04 lb. 80201 11/4" x 3/e" 40 '/,e" 0.11 lb. 80076 1" 40 '/8" 0.11 lb. 80101 1" 40 '/e" 0.06 lb. 80202 1V4" x 1" 40 3/1e" 0.12 lb. 80077 1'/4' 40 3/16" 0.12 lb. 80102 11/4" 40 '/2" 0.10 lb. 80203 1'/2" x 3/4" 80 Vs" 0.16 lb. 80078 11/2" 80 3/1e" 0.25 lb. 80103 11/2" 80 '/e" 0.20 lb. 80204 1'/4" x 1" 80 '/2" 0.14 lb. 80079 2" 80 3/1e" 0.38 lb. 80104 2" 80 '/a' 0.31 lb. 80205 11/2" x 11/4" 80 3/a' 0.17 lb. 80080 2'/2" 80 3/,e" 0.67 lb. 80105 21/2" 80 '/e" 0.58 lb. 80206 2" x 3/4" 80 3/4" 0.27 lb. 80081 3" 80 3/,e 0.91 lb. 80106 3" 80 1" 0.88 lb. 80207 2" x 1" 80 "/16" 0.26 lb. 80208 2" x 1'/4' 80 9/1e 0.24 lb. no 80209 2" x 11/2" 80 1/46" 0.19 lb. Grooved _ __ 80215 2'/2" x 1" 80 Vile" 0.42 lb. Coupling Pipeo /4 .o 80214 21/2" x i' " 80 13/4' 0.45 lb. Adapter ®---� 80213 2'/2" x 1'/2" 80 l'/e" 0.46 lb. 80211 2'/2" x 2" 80 19/16" 0.29 lb. Part No. Size Sch. T/O Wt. Pipe OD 80210 3" x 2" 80 2 3/1e" 0.72 lb. 80160 11/4' x 11/4' Grooved 40 21/4s' 0.78 lb. 1'/4" (1.660") 80212 3" x 21/2" 80 1"/,6" 0.47 lb. 80161 1'/2" x 11/2" Grooved 80 2 e/,e" 0.95 lb. 1'/2" (1.900") 80162 2" x 2" Grooved 80 23/16" 1.42 lb. 2" (2.375") _MIL_ 80163 21/2" x 2'/2" Grooved 80 2'/16' 2.28 lb. 21/2" (2.875") a °, 80164 3" x 3" Grooved 80 21/4" 3.00 lb. 3" (3.500") Reducing .. ll �il_TI1 80168 3" x 76.1mm Grooved 80 2'/4" 2.72 lb. 76.1mm (3.000") Tee TI°' ,• T/°' iir/0 Part T/O Wt. �► No. Size Sch. 1 2 3 lb. Female _._.L�l� _ 80132 /4" x 3/a" x 1" 40 3/4" /4' le" 0.14 �� Adapter , � 80133 1" x 3/4' x 3/4" 40 '/2" "/,e" 3/4" 0.14 80134 1" x 3/4' x 1" 40 '/e" 3/4" 3/4" 0.17 Part No. Size Sch. T/O Wt. 80260 1" x 1" x'/4" 40 3/4' 3/4" "/,e" 0.16 80142 3/4" x e/" NPT 40 '/e" 0.41 lb. 80135 1'/4' x 1"x 3/4' 40 16" 3/4' '1/46" 0.21 80145 1" x 1" NPT 40 3/4' 0.63 lb. 80136 1'/4" x 1" x 1" 40 "/,e" 3/4" 1°/,a" 0.22 80146 1'/4' x 174" NPT 40 '/a" 1.03 lb. 80137 11/4' x 1"x 11/4' 40 13/,6" "/s' 13/,6" 0.26 80147 1'/2" x 1'/2" NPT 80 1" 1.42 lb. 80261 1'/4" x 1'/4" x 3/4" 40 '/e" '/a" '/a" 0.23 80148 2" x 2" NPT 80 13/e" 2.66 lb. 80262 1'/4"x 1'/4"x 1" 40 3/4" 3/4" '/e" 0.26 80138 11/4" x 1'/" x 1'/2 80 1" 1' 1" 0.43 TO 80140 1'/2" x 1'/4 x 3/4" 80 1/2" '/e" 1" 0.36 �� 80141 1'/2" x 1'/4" x 1" 80 '/" 'la" 1'1e" 0.38 Male -.-! .--.-.-._-.-. 80263 1'/2"x 11/2"x 3/4" 80 9/,fi" 9h6" 1" 0.36 Adapter L,�__ 80264 1'/2"x 1'/2"x 1" 80 9A6' '/e" 1" 0.38 80275 1'/2" x 1'/2" x 11/4" 80 '/e' '/e" 1" 0.45 Part No. Size Sch. T/O Wt. 80265 2" x 2" x 3/4" 80 3/4' 3/4" 13/a' 0.61 80157 3/4" x 3/4" NPT 40 1'/,6" 0.33 lb. 80266 2" x 2" x 1" 80 'la" '/a" 13/e" 0.66 80158 1" x 1" NPT 40 13/a" 0.56 lb. 80274 2" x 2" x 11/4" 80 1" 1" 13/e" 0.74 80267 2" x 2" x Pb' 80 1'/e" 11/d' 13/8" 0.78 TIO 80271 2'/2" x 2'/2" x 1" 80 1"/1e" 111/4e'"" 1°/,e" 1.43 .$!` 80272 21/2" x 2'h" x 1'/4" 80 1"/,6" 1"/,6' 19/,e" 1.46 Reducing I 80273 2'2 x 2'/2" x 1'/2' 80 1"/,6" 1"/,6" 19/,6" 1.48 Coupling 80270 3 80276 21/2" x 2'/2" x 2" 80 1"/,e" 1"/4' 19/,6" 1.50 x 3" x 11/2 80 13/4" 13/4' 113/,6' 2.28 Part No. Size Sch. T/O Wt. 80268 3" x 3" x 2" 80 13/4" 13/4' Via" 2.25 80220 1"x 3/4" 40 '/e" 0.08 lb. 80269 3" x 3" x 2'/2' 80 13/4" 13/4" 1"/,6" 2.44 T/O T/O Sprinkler Head Adapter _.-11 ._ Sprinkler Head Adapter _.�Ini._ with Brass Threaded Insert „ with Brass Threaded Insert ___ Part No. Size Sch. T/O Wt. Part No. Size Sch. T/O Wt. 80175E 3/4" x '/2" NPT 80 '/,e" 0.20 lb. 80175W 3/4"x '/2" NPT 40 'he 0.19 lb. 80176E 1" x 1/2" NPT 80 'he" 0.22 lb. 80176W 1"x'/2" NPT 40 '/le" 0.18 lb. 80177WL 3/4" x '/2" NPT 40 3/,8' 0.16 lb. 80179 1 x 3/<" NPT 40 /a" 0.43 lb. Lim � T/O' i I 7'O Sprinkler Head Adapter , Bahk Css i � ._ �.. m with Brass-to-Back Threadedro Insert Enonp r, with hlB as TO ��1s Threaded Insert _am. T/02 Tio' Part No. Size Sch. T/O Wt. Part T/O Wt. 80177L 3Id' x'h" NPT 40 1/2' 0.16 lb. No. Size Sch. 1 2 lb. 80178 1" x'/i' NPT 40 12" 0.20 lb. 80462 1" x 1" x 'Is" NPT x 'Is" NPT 40 5/e" 1'Is" 0.46 80463 1" x 1"x 'Is" NPT x '/2" NPT 40 5/s" 15/,8" 0.47 no' i Sprinkler Head Adapter �� .�� 1 illo 90° Elbow with Brass Threaded Insert All T/0' Back-to-Back Tee T/0 inQ ai 11 i _ 'Tem. with Brass Threaded Insert T .r-�� .. i Te . Part T/O Wt. Part Size Sch. T/O Wt. No. Size Sch. 1 2 lb. No. 1 2 lb. 80199 3/4" x'/2" NPT 40 5/e" 15/1e" 0.20 80459 1" x Vs" NPT xVs" NPT 40 "/,s" 15/,e" 0.48 80189 1" x is" NPT 40 13/,e" 13/,8" 0.26 80460 1" x'/s' NPT x'Is" NPT 40 11/,s" 1'/8" 0.46 Part T/O Wt. No. Size Sch. 1 2 3 lb. 80250 3/4" x 3/4" x 1/2" NPT 40 5/e" a/s" 1" 0.22 i 80251 1" x 1" x Is' NPT 40 "/,s" II/1e" 13/s" 0.29 _AM. 80249 1" x 1" x 1" NPT 40 1$/18' 'she" 1'/s" 0.73 Sprinkler Head Adapter MP 17°' 80256 11/4"x 1" x"Is" NPT 40 '/,s' VIe 1'/s" 0.30 Tee 11011 ._-- 80252 11/4" x 11/4" x"Is" NPT 40 '/,s" 'Ile" 1'/e" 0.31 with Brass Threaded Insert 80257 1'/s" x 1'/4" x 1/2" NPT 80 ehs' "Is" 17hs" 0.43 no' 101101 von 80254 1'/2" x 112"x '/2" NPT 80 a/,s" 3/1e" 17/1s" 0.46 80258 2" x 11/2"x '/s" NPT 80 '/2" 5/s" 15/s" 0.56 80253 2" x 2" x 'Is" NPT 80 72" 1/s 15/8" 0.62 Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten(10)years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten(10)years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse,improper installation,corrosion,or which have not been installed,maintained,modified or repaired in accordance with applicable Standards of the National Fire Protection Association(NFPA),and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced,at Tyco Fire Products sole option. Tyco Fire Products neither assumes,nor authorizes any person to assume for it,any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE,IN CONTRACT,TORT,STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY,FOR INCIDENTAL,INDIRECT,SPECIAL OR CONSEQUENTIAL DAMAGES,INCLUDING BUT NOT LIMITED TO LABOR CHARGES,REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCT'S LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED,INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. t qCO/Flow Control/products SDI SMITH ., COOPER SGI INTERNATIONAL Ductile Iron Threaded Fittings *ALL FITTINGS 100% AIR TESTED *ASME/ANSI B16.3 ClaUS *ISO 9001:2000 MANUFACTURER *ASTM A536 Grade 65,45,12 LISTED *LISTED/APPROVED AT 500 PSI *ASME/ANSI B 1.20.1 APPROVED Ductile Iron 90°Elbow Ductile Iron Coupling Figure 35E Size A Wgt Figure 35CP Size A Wgt .-A-► 1/2 1.13 0.24 1/2 1.38 0.18 ��� ♦ 3/4 1.31 0.40 3/4 1.63 0.26 A 1 1.50 0.64 t 1 1.75 0.44 I A 1-1/4 1.75 0.95 A 1-1/4 2.00 0.54 1-1/2 1.94 1.24 llr 1-1/2 2.19 0.71 I 2 2.25 1.74 2 2.62 1.15 2-1/2 2.70 3.28 2-1/2 3.00 2.29 Ductile Iron Reducing 90°Elbow Ductile Iron Cap Figure 35RE Size A B Wgt Figure 35C Size A Wgt 3/4 x 1/2 1.22 1.20 0.33 1/2 0.87 0.15 1 x 1/2 1.36 1.26 0.44 _ 3/4 0.97 0.22 1 x 3/4 1.45 1.38 0.53 1 1.16 0.33 1-1/4 x 1/2 1.53 1.34 0.64 F7t 1-1/4 1.28 0.54 1-1/4 x 3/4 1.63 1.45 0.75 f- I i 1-1/2 1.33 0.68 1-1/4 x 1 1.67 1.58 0.77 2 1.45 0.96 • ~A-.. 1-1/2 x 1/2 1.75 1.52 0.90 2-1/2 1.70 1.80 t 1-1/2 x 3/4 1.75 1.52 0.95 i 1-1/2 x 1 1.80 1.65 0.99 Ductile Iron Hex Bushing ' 1-1/2 x 1-1/4 1.88 1.82 1.14 Figure 35HB Size A Wgt 2 x 1/2 1.97 1.60 1.35 1 x 1/2 1.06 0.22 2 x 3/4 1.97 1.60 1.39 1 x 3/4 1.06 0.18 2 x 1 2.02 1.73 1.58 MINIM• T 1-1/4x1 1.19 0.31 2 x 1 1/4 2.10 1.90 1.62 `r A 1-1/2 x 1 1.25 0.53 2 x 1-1/2 2.16 2.02 1.67 �r 1-1/2 x 1-1/4 1.25 0.35 2-1/2 x 1-1/2 2.51 2.16 2.32 �' 2 x 1 1.38 0.75 2-1/2 x 2 2.60 2.39 3.01 2 x 1-1/4 1.38 0.69 2 x 1-1/2 1.38 0.62 Ductile Iron Brass Seat Union Figure 35U Size A Wgt Ductile Iron 45°Elbow 1/2 1.88 0.47 Figure 35F Size A Wgt .... . 3/4 2.00 0.66 0 ` 1/2 0.88 0.22 ■_■ A 1 2.19 1.08 .0A 3/4 0.98 0.33 1-1/4 2.50 1.54 1 1.13 0.48 i-il 1 V 1-1/2 2.62 2.03 ` 1-1/4 1.29 0.73 2 3.12 3.15 4 1-1/2 1.44 0.93 A 2 1.69 1.55 i Ductile Iron Tee 2-1/2 I 1.95 2.70 Figure 35T Size A Wgt FA-; f--Ai 1/2 1.13 0.33 Ductile Iron Beam Clamps 3/4 1.31 0.50 Figure 35SP T -S �- 1 1.50 0.85 Size A Wgt A1-1/4 1.75 1.30 3/8 0.75 0.31 !If 1 1/2 1.94 1.63 + 1/2 0.75 0.54 2 2.25 2.63 - - 2-1/2 2.70 4.55 • sCl SMITE - Cooi i' sGi INTERNATIONAL Ductile Iron Threaded Fittings c ® us *ALL FITTINGS 100% AIR TESTED *ASME/ANSI B16.3 *ISO 9001:2000 MANUFACTURER *ASTM A536 Grade 65,45,12 LISTED *LISTED/APPROVED AT 500 PSI * ASME/ANSI B 1.20.1 APPROVED Ductile Iron Bull Head Tee Ductile Iron Reducing Tee Figure 35RT Size A B C Wgt t 3/4 x 3/4 x 1/2 1.20 1.20 1.22 0.46 Figure 35BT 1 x 1/2 x 1 1.50 1.36 1.50 0.70 1 x3/4x3/4 1.38 1.31 1.45 0.68 1 x 3/4 x 1 1.50 1.45 1.50 0.77 Size A B C Wgt 1 x 1 x 1/2 1.26 1.26 1.36 0.66 3/4 x 3/4 x 1 1.45 1.45 1.37 0.68 1 x 1 x 3/4 1.38 1.38 1.45 0.73 1 x 1 x 1-1/4 1.67 1.67 1.58 0.97 1-1/4 x 1/2 x 1-1/4 1.75 1.53 1.75 1.04 1 x 1 x 1-1/2 1.80 1.80 1.65 1.14 1-1/4 x 3/4 x 1-1/4 1.75 1.62 1.75 1.09 1-1/4 x 1 x 1-1/2 1.88 1.80 1.82 1.43 1-1/4 x 1 x 1/2 1.34 1.26 1.53 0.81 1-1/4 x 1-1/4 x 1-1/2 1.88 1.88 1.82 1.52 1-1/4 x 1 x 3/4 1.45 1.38 1.63 0.90 1-1/4 x 1-1/4 x 2 2.10 2.10 1.90 2.00 1-1/4 x 1 x 1 1.58 1.50 1.69 1.03 1-1/2 x 1-1/4 x 2 2.16 2.10 2.02 1.94 1-1/4 x 1 x 1-1/4 1.75 1.69 1.75 1.10 1-1/2 x 1-1/2 x 2 2.16 2.16 2.02 2.00 1-1/4 x 1-1/4 x 1/2 1.34 1.34 1.53 0.87 2 x 2 x 2-1/2 2.60 2.60 2.39 3.67 1-1/4 x 1-1/4 x 3/4 1.45 1.45 1.62 0.96 1-1/4 x 1-1/4 x 1 1.58 1.58 1.67 1.10 Ductile Iron Hex Reducing Coupling 1-1/2 x 1/2 x 1-1/4 1.81 1.56 1.88 1.37 Figure 35RC Size A Wgt 1-1/2 x 1/2 x 1-1/2 1.94 1.66 1.94 1.42 1 x 1/2 1.69 0.40 1-1/2 x 3/4 x 1-1/4 1.94 1.66 1.88 1.42 1 1 x 3/4 1.69 0.38 1-1/2 x 3/4 x 1-1/2 1.94 1.75 1.94 1.47 A 1-1/4 x 3/4 2.06 0.53 1-1/2 x 1 x 1/2 1.44 1.25 1.69 0.97 1 I 2 x 1(not hex) 2.81 0.53 1-1/2 x 1 x 3/4 1.50 1.44 1.75 1.14 1-1/2 x 1 x 1 1.65 1.50 1.80 1.14 1-1/2 x 1 x 1-1/4 1.82 1.67 1.88 1.47 Ductile Iron Cross &Reducing Cross 1-1/2 x 1 x 1-1/2 1.94 1.80 1.94 1.52 Figure 35X Size A B Wgt 1-1/2 x 1-1/4 x 1/2 1.41 1.34 1.66 1.03 1 1.50 1.50 0.97 1-1/2 x 1-1/4 x 3/4 1.52 1.45 1.75 1.10 A ." A - 1-1/4 1.75 1.75 1.59 1-1/2 x 1-1/4 x 1 1.65 1.58 1.80 1.31 ii 1-1/2 1.94 1.94 1.89 1-1/2 x 1-1/4 x 1-1/4 1.82 1.75 1.88 1.52 B 2 2.25 2.25 ' 2.93 1-1/2 x 1-1/4 x 1-1/2 1.94 1.88 1.94 1.50 Figure 35RX 1-1/2 x 1-1/2 x 1/2 1.41 1.41 1.66 1.14 B Size A ' B Wgt 1-1/2 x 1-1/2 x 3/4 1.52 1.52 1.75 1.23 1-1/4 x 1 1.67 1.58 1.25 1-1/2 x 1-1/2 x 1 1.65 1.65 1.80 1.38 1-1/2 x 1 1.80 1.65 1.48 1-1/2 x 1-1/2 x 1-1/4 1.82 1.82 1.88 1.50 2 x 1 2.02 1.73 2.64 2 x 1 x 2 2.25 2.02 2.25 ' 2.18 2 x 1-1/4 x 2 2.25 2.10 2.25 2.31 Ductile Iron Plugs 2 x 1-1/2 x 1/2 1.49 1.41 1.88 1.50 Figure 35SP Size A Wgt 2 x 1-1/2 x 3/4 1.60 1.52 1.97 1.61 1/2 0.94 0.10 2 x 1-1/2 x 1 1.73 1.65 2.02 1.65 3/4 1.12 0.18 2 x 1-1/2 x 1-1/4 1.90 1.82 2.10 2.03 A 1 1.25 0.28 2 x 1-1/2 x 1-1/2 2.02 1.94 2.16 2.37 1-1/4 1.37 0.50 2 x 1-1/2 x 2 2.25 2.16 2.25 2.53 1-1/2 1.44 0.70 2 x 2 x 1/2 1.49 1.49 1.88 1.50 2 1.50 0.90 2 x 2 x 3/4 1.60 1.60 1.97 1.67 2 x 2 xl 1.73 1.73 2.02 1.91 2 x 2 x 1-1/4 1.90 1.90 2.10 2.05 2 x 2 x 1-1/2 2.02 2.02 2.16 2.11 thcz2 510 C.P.V.C. - STEEL - COPPER HANGER 40) -- • -- r SIZE-3/4"thru 3"pipe. MATERIAL-Carbon Steel. FINISH-Mil.Galvanized. LISTINGS- c u s EX 4231,EX 2551 FUNCTION-Hanger/restrainer on C.P.V.C.,Copper or Steel pipe. INSTALLATION- Per N.F.P.A. 13, 13R and 13D on top,bottom or side of beam. Space by pipe type. Hanger/Restrainer a On copper-insulate pipe FASTENERS-UL Listed per NFPA 13. r - in WOOD: 3/4" -3"CPVC pipe-#905 screw-no pre-drill. 3/4" -2"Copper pipe-#905 screw-no pre-drill. 3/4" -2"Steel pipe- 1/4"x11/2" lag screw-no pre-drill. (o ®) Stabilize-Only in STEEL: 3/4" -3"CPVC pipe- 1/4"or#14 Tek Screw. x #v,«wr a : .imsw 3/4" -2"Copper pipe- 1/4"or#14 Tek Screw. 3/4"-2" Steel pipe- 1/4"or#14 Tek Screw. FEATURES *Offset edge eliminates abrasion. *Retainer dimples secure hanger to pipe during installation. *Required AFCON#905 screw has 5/16"hex head-included. ORDERING-Part#and pipe size. *CAN ALSO BE USED TO REPLACE - #500 Pipe Strap #520 Tin Strap 04/03 l�G G0 511 PIPE / C.P.V.C. HANGER SIDE MOUNT ► t • I II. I I ■ I � • Side View SIZE-3/4"thru 2"pipe. As Hanger on Metal Stud MATERIAL-Carbon Steel. FINISH-Mil. Galvanized. LISTINGS- © EX 4231 c ' us EX 2551 FUNCTION-Use on C.P.V.C. or Copper piping installed per N.F.P.A. 13, 13R and 13D. Acts as a hanger and or restrainer. INSTALLATION-Install on top or bottom of beam. Hanger spacing by pipe type-per NFPA 13. �— NOTE:On copper-insulate pipe. ® UL listed fasteners tested per NFPA 13,as follows. 0 IN WOOD: CPVC and Copper Pipe-#905 listed screw furnished with product. IN STEEL: CPVC and Copper Pipe- 1/4"or#14 Tek Screw. FEATURES * Offset edge eliminates abrasion. *Retainer dimples secure hanger to pipe during installation. *Required#905 screw has 5/16 hex head- needs no pre-drilling. ORDERING-Part#and pipe size. V Front View As Hanger on Metal Stud 12/02 ..Zi7vg@§0 513 PIPE / C.P.V.C. HANGER SINGLE FASTENER 0 SIZE-3/4"thru 2"pipe. MATERIAL-Carbon Steel. FINISH-Mil.Galvanized. LISTINGS- CO EX 4231 c us EX 2551 FUNCTION-Use on C.P.V.C.,Copper or Steel piping installed per N.F.P.A. 13, Hanger la 13R and 13D.Hanger when tab is up and fastener in horizontal position. Restrainer when tab is down and fastener in horizontal position. INSTALLATION- Install on side of beam. Restrainer Can install on top of beam to stabilize pipe. ' Hanger spacing by pipe type-per NFPA 13. NOTE:On copper-insulate pipe. _ UL listed fasteners tested per NFPA 13,as follows. ® Stabilize-Only IN WOOD: CPVC and Copper Pipe-#905 listed screw furnished with product. iratia214034 tWit-.5i1C,:'44..renWeelaktR Steel- 1/4"xl 1/2"lag screw-needs no pre-drilling. IN STEEL: fun CPVC,Copper and Steel Pipe- 1/4"or#14 Tek Screw. IN CONCRETE: CPVC,Copper and Steel Pipe-Shot type fasteners, "Only when installed prior to pipe insertion". FEATURES *Offset edge eliminates abrasion. *Required#905 screw has 5/16 hex head- needs no pre-drilling. ORDERING-Part#and pipe size. 12/02 . . 7r:gr001,§) 514 OFFSET #905'#906�.i C.P.V.C. - STEEL - COPPER HANGER mill I1 f ' 1! 1p000' ...4r1": SIZE-3/4"thru 2"pipe. MATERIAL-Carbon Steel. mosiminimimmilIE • FINISH-Mil.Galvanized.. LISTINGS- c u us EX 4231,EX 2551 PATENT-No.6,648,278. FUNCTION- To support horizontal piping-C.P.V.C.,Copper or Steel. Hanger and restrainer in listed mounting positions-Top,Bottom or Side. v ' o • D Provides stability on vertical piping. 4 . INSTALLATION- Per N.F.P.A 13, 13R and 13D on 4 i v top,bottom or side of building element. Space by pipe type. . 4 On 3/8"wood web use#906 backing nuts. -see drawing. "' Snap over pipe then squeeze strap back allowing pipe to slide freely. FASTENERS-UL Listed per NFPA 13 in WOOD: � 1 CPVC pipe-#905 screw-no pre-drill. Copper pipe- #905 screw- no pre-drill. Steel pipe- 1/4"xl 1/2"lag screw- no pre-drill. in STEEL: CPVC pipe- 1/4"or#14 Tek Screw. Copper pipe- 1/4" or#14 Tek Screw. Steel pipe- 1/4"or#14 Tek Screw. MD FEATURES � * 1 1/2"Offset. * 3/4"and 1"pipe size made with common center-line. * Leg design produces superior strength. -■ s *Offset edge eliminates abrasion. --1111 *Required AFCON#905 screw has 5/16"hex head- included liii ORDERING-Part#and pipe size. AFCON#906 sold separately. 4/04 PIPE RINGS (;Z)) ,A NIL . Fig. 69 Adjustable Swivel Ring,Tapped Per NFPA Standards Size Range: 1/2"through 8" Material: Carbon steel Finish: O Galvanized Service: Recommended for suspension of non-insulated stationary pipe line. Maximum Temperature: 650°F Approvals: Complies with Federal Specification A-A-1192A(Type 10) +' WW-H-171-E(Type 10)and MSS-SP-69(Type 10). UL Listed and FM Approved(Sizes 3/4"-8"). ,5 Features: • Threads are countersunk so that they cannot become burred or damaged. • Knurled swivel nut provides vertical adjustment after piping is in place. • Captured swivel nut in the 1/2"through 3"sizes. Ordering: Specify size,figure number and name. i fA Fig.69: Loads (Ibs)•Weight(Ibs)•Dimensions(in) MI nig Pipe Size Max Load Weight Rod Size A B C F iiii 1/2 0.10 21/a 2 13/16 F 3/4 0.1 23/4 _-17/8 115/16 , 1 0.10 29/16 111/16 1 300 _ . 11/4 0.10 25/8 13/4 1/8 1 1/2 0.10 3/8 23/4 - 1 7/8 2 0.11 31/4 2 3/8 1 /8 21/2 0.20 4 23/4 15/16 525 3 0.20 313/16 215/16 19/16 4 650 0.30 411/16 313/16 -L -- 1 9/16 5 0.54 55/16 j 43/8 6 1,000 0.65 1/2 611/16 59/16 21/4 8 1.00 8 1 7 211/16 Pipe Hanger Submittal Sheet Project: 1122 Architect/Engineer: Approval Stamp: Date: Phone: Contractor: A&A Address: Notes 1: Notes 2: Back to Application Guide TEXTRON Fastening Systems SPECIFICATIONS HangerMate® Threaded Rod EZH665 HangerMate Anchors Anchoring System Application Material: EZH665 Anchors Wood Specification: 5/16" threaded shank diameter, one-piece anchor with twin-lead threads high-low, waxed threads, Type 17 point and cross-drilled R� ))llII,, head to accept 3/8"-16 threaded rod components )1) headFM Approvals and UL Listings: cross-drilled '�� to accept • cULus Listed for pipe up to 3-1/2" diameter 3/8-16 threaded rod Head Style: components 3/4" high, 9/16" diameter head cross-drilled and tapped to accept 3/8"-16 threaded components Features & Benefits Drive Hex Size: • Cross-drilled and tapped for attaching 3/8-16 1/2" across flats threaded components to wood • Solid, one piece cold formed part; head cannot spin Shank Length: off or unscrew from body 2-1/4" • Type 17 point cuts threads into wood and wax Shank Threads: coating reduces installation torque 5/16"-14 high-low threads (waxed) Point Type: Performance Values for EZH665 Anchor Type 17 (waxed) with shank slot Average Ultimate Pull-Out Value(Ibs) Material & Heat Treat Douglas Fir Southern Pine Hem Fir Carbon steel (AISI C10B21); no heat treat 1801 1460 1451 Finish: Zinc plated per ASTM B633 Type II Class 12 Installation Tools: • HangerMate drive socket: EZE21 5 with safety set feature; automatically disengages when anchor is seated • Recommended power tool: Contractor-grade screw gun; 12 volt min. cordless or 6 amp. corded tool • In most applications, a pre-drilled hole is not needed. In exceptionally hard wood, drill hole only to minimum size required. 1.The loads indicated above are average ultimate values achieved under laboratory conditions and appropriate safety factors should be applied for design purposes. 2.NFPA(National Fire Protection Assoc.)minimum fastening requirements are live times the weight of a 15 ft section of water-Filled pipe plus 250 lbs.This is 1475 lbs.for 4"pipe. 3.All test values were obtained using 3/8-16 rod.When 1/4-20 rod is used,the strength of the rod may be less than the pull-out values of the anchors. For more information, contact 4.Loads were determined by testing products in the orientation for which they were Textron Fastening Systems • 1.800.435.7213 designed to be used.End-drilled ports were pulled in line with the anchor's axis while cross-drilled ports were tested with the force perpendicular to the axis. e-mail: info@tfs.textron.com HangerMate®is a renistered trademark of Textron Inc. U TOLCO www.tolco.com NIBCO Revision 12/3/2008 n • Fig. 4L ,C US LATE° Longitudinal "In-Line" Sway Brace Attachment Size Range — 2" through 8" IPS. le, r Material — Carbon Steel * Function — For bracing pipe against sway and seismic disturbance. yr/'�� Approvals — Underwriter's Laboratories Listed in the USA(UL)and * * '~ Canada (cUL)2" - 8". Approved by Factory Mutual Engineering (FM), 4 r►.. 2" - 8" pipe. Installation Instructions — The Fig. 4L is the "braced pipe" attachment component of a longitudinal sway brace assembly. It is intended to be D A combined with the "bracing pipe" and TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install — Place the Fig. 4L over the pipe to be braced and tighten bolts. Then engage "bracing pipe" into jaw opening and tighten set bolt until hex head snaps off. Jaw attachment can pivot for adjustment to C \� proper brace angle. Finish — Plain Note — Available in Electro-Galvanized and HDG finish. Order By — Figure number, pipe size and finish. • r COidop. II Dimensions •Weights Max. Rec. *Max Rec. Sizes A C D Size Load Lbs. Load Lbs. WP.p/rox 253 (cULus) (FM) 21/2 6�/is 2�h 23/a 1/2 2015 3000 3 7 23/a 31A6 1/2 2015 1550 268 4 81 3% 311/16 1/2 2015 1550 348 o 5 93/4 37/6 43/a 1/2 2015 1450 380 Longitudinal Brace 6 111/2 5 51/8 1/2 2015 1450 640 8 131/4 611h6 61/2 1/2 2015 1450 728 A' '•I *Load shown is allowable with brace installed, between 30°-90°.No reduction of load v based on brace angle is required. \ FM approved when used with 1",11/4', 11/2"or 2"Sch.40 brace pipe. \G\ s, p 4-Way Riser Brace (Plan view) TOLCO®brand bracing components are designed to be compatible ONLY with other TOLCO®brand bracing components,resulting in a Listed seismic bracing assembly. DISCLAIMER - NIBCO does NOT warrant against the failure of TOLCO®brand bracing components,in the instance that such TOLCO®brand bracing components are used in combination with products,parts or systems which are not manufactured or sold under the TOLCO®brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect,incidental or consequential damages of any kind, ` including but not limited to loss of business or profit,where non-TOLCO brand bracing components have been,or are used. OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE.•CORONA,CA 92879•PH: 951.737.5599•FAX: 951.737.0330 CUSTOMER SERVICE•800.786.5266III www.tolco.com V TOLCO www.tolco.com NIBCO Revision 4/6/2010 Fig. 980 - Universal Swivel Sway Brace Attachment c u� US LISTED Size Range — One size fits bracing pipe 1" thru 2", TOLCO 12 gauge channel, and all 4> structural steel up to 1/4" thick. Material — Carbon Steel Component of State of Function — Multi-functional attachment to structure orto-No. California OSHPD Approved Seismic Restraints System braced pipe fitting. Features — This product's design incorporates a concen- trj , attachment opening which is critical to the performance of structural seismic connections. NFPA 13 (2010) 9.3.5.8.4 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle. 1 (1 Break off bolt head assures verification of proper installation. Installation — The Fig.980 is the structural or transitional A ^` attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the B "bracing pipe" and TOLCO "braced pipe" attachment, Fig. 1000, 1001, 2002, 4L, 4A or 4B to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install — Place the Fig. 980 onto the "bracing pipe". Tighten the set bolt until set bolt head breaks off. Attachment can pivot for adjustment to proper brace angle. Approvals — Underwriters Laboratories Listed in the USA(UL) and Canada(cUL). Approved by Factory Mutual • Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development(OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. • Note — The Fig. 980 Swivel Attachment and the Fig. 1001, Fig. 1000 , Fig. 2001 or Fig. 4A Pipe Clamp make up a sway brace system of UL Listed attachments and bracing materials which satisfies the requirements of Underwriters' Laboratories and the National Fire Protection Association (NFPA) Finish — Plain Note — Available in Electro-Galvanized finish. Order By — Figure number and finish. 7-5 Pat.#6,273,372, Pat.#6,517,030, Pat.#6,953,174, Pat.#6,708,930, Pat.#7,191,987, Pat.#7,441,730, Pat.#7,669,806 \C/ , N Lateral Brace Dimensions •Weights Max. Design **Max. Design Approx. A B H* Load Lbs. Load Lbs. (cULus) (FM) Wt./100 51/4 1 7/e 17/32 2765 2800 132 * Available with hole sizes to accommodate up to 3/4"fastener. Consult factory. **Load shown is allowable with brace installed,between 30°-90°. No reduction of load based on brace angle is required. TOLCO®brand bracing components are desgined to be compatible ONLY with other TOLCO®brand bracing components,resulting in a Listed seismic bracing assembly. DISCLAIMER — NIBCO does NOT warrant against the failure of TOLCO®brand bracing components,in the instance that such TOLCO®brand bracing components are used in combination with products,parts or systems which are not manufactured or sold under • the TOLCO®brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,where non-TOLCO brand bracing components have been,or are used. OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE.•CORONA.CA 92879•PH: 951.737.5599•FAX: 951.737.0330 CUSTOMER SERVICE•800.786.5266 www.rolco.com y TOLCO www.tolco.com NIBCO Revision 12/3/2008 0 Fig. 1001 - Sway Brace Attachment Component of State of CO US LISTED California OSHPD Approved Size Range — Pipe size to be braced: 21/2" thru 8" IPS.* Pipe size Seismic Restraints System used for bracing: 1" and 11/4" Schedule 40 IPS. Material — Carbon Steel Function — For bracing pipe against sway and seismic distur- bance. The pipe attachment component of a sway brace system: The Fig. 1001 is used in conjunction with a TOLCO 900 Series fitting and joined together with bracing pipe per NFPA 13, forming a com- plete sway brace assembly. "c Features — Can be used to brace schedules 7 through 40 IPS. Field adjustable, making critical pre-engineering of bracing pipe length unnecessary. Unique design requires no threading of brac- ing pipe. Can be used as a component of a four-way riser brace. Comes assembled and ready for installation. Fig. 1001 has built-in visual verification of correct installation. See installation note below. Installation Note — Position Fig. 1001 over the pipe to be braced and tighten two hex head cone point set bolts until heads bottom out. A minimum of 1" pipe extension is recommended. Brace pipe can be installed on top or bottom of pipe to be braced. Approvals — Underwriters Laboratories Listed in the USA (UL) Maximum Design Load and Canada (cUL). Approved by Factory Mutual Engineering (FM). Sch. 7 1600 lbs. Included in our Seismic Restraints Catalog approved by the State Sch. 10 &40 w/1" Brace Pipe 2015 lbs. of California Office of Statewide Health Planning and Development Sch. 10 &40 w/1 /4 Brace Pipe 2765 lbs. (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic FM Approved Design Loads* Restraint Systems Guidelines. 21/2" - 2400 lbs. Finish — Plain 3" - 4" - 2500 lbs. Note — Available in Electro-Galvanized and HDG finish. 5" 8" 1500 lbs. Order By — Indicate pipe size to be braced followed by pipe size used for bracing, figure number and finish. Important Note — The Fig. 1001 is precision manufactured to perform its function as a critical component of a complete brac- ing assembly. To ensure performance,the UL Listing requires that the Fig. 1001 must be used only with other TOLCO bracing products. The Fig 1001 is not intended for use with the Fig. 907 4-Way Longitudinal Brace Attachment. ri ® OFFICE/MANUFACTURING FACILITY•1375 SAMPSDN AVE.•CORONA,CA 92879•PH- 951.7375599•FAX: 951 737.0330 CUSTOMER SERVICE•800.7865266 www.tolco.com