GRIFFITH
ROOFING co . ESTIMATE
6815 S.W. 1 1 1th Ave.
Beaverton, OR 97008
Construction Contractors Board#925
Job No. Date
Owner Phone
Address Cell
Job Address Fax
SPECIFICATIONS
Email:
Estimate Cost
Quantity Price Quantity Price
Labor
Total Cost
Profit
Selling Price
1 t‘i - • ,-- .
.. _..._,„
dip
1 7-
1 , '
(
<-7
344)1 /SD'
/do'
1110
;s
11 Z.
7 ,I
/ Z.- 3
0
51‹...rers Z. / 0
2.
't x'1
/ / 6
/2 24,,/,i,pi. ( ---- /2.
r•-.. ._ 7 ...5-
L i
9Cla ° j?;0 t.lie,s 17,i 3 5- /
ii-)6c,Gi ill6d44. C 2 C...) S-
fpn.i- /r .`„:.. Z
- 1
—
ZVI x 20/ 0 ..5....
;
Zid dcsnc-L i/ ,.5-10- -'6'-ei ,L,f' r-1/) , i11
(1:;), 1 Sei s /a.)s-ts--ODO 6,7 i ' e: ."of,/
M-GOUP
Design •Consulting•Value Engineering Massaad Engineering Group Inc.
SITE OBSERVATION REPORT
July 8, 2021
RE: 9900-9914 SW Tigard St
Tigard, OR 97223
Date of Observation: July 7, 2021
Time In: 9:00 am
Time Out: 9:30 am
Attendees: Sam Rediske(M-GROUP Inc)
Greg Stone (Griffith roofing Co.)
PART I- PURPOSE
The purpose of this report is to evaluate the existing roof structure of the above building and
determine the feasibility of adding a roof layer over the top. The proposed additional layer is 3-ply
roofing assembly with maximum weight of 2.0 psf.
PART II- FINDINGS
The structure is an "L" shape industrial structure constructed in the 1970's and has construction
practices of such era. The structure is concrete walls with wood roof system. The roof structural
system comprises of 2x decking clear spanning 6x14 beams at eight feet on center between main
girder lines approximately twenty-four feet apart. Not all roof area was observed, but enough areas
were exposed to determine that the general roof structure system. The roof assembly is as follows:
• 3-Ply roofing 2.0 psf
• 2x decking 4.5 psf
• 6x14 @8'-0"oc 2.0 psf
• Insulation allowance 1.0 psf(Conservative)
• Miscellaneous Allowance 1.0 psf(Conservative)
Total 10.5 psf Conservative
The proposed roof overlay is as follows
• 3-Ply Roofing Membrane 2.0 psf
The total roof dead load (including new overlay) is 12.5 psf
PART III-CALCULATIONS
The roof structure is framed with 2x decking with controlled random layout clear spanning 6x14 beams
@8'-0" OC which in turns spans between girder beams spaced approximately 24 feet apart. For the
calculation purposes we checked the critical members, decking and purlins for code minimum deflection
criteria of L/120 (Total Load Deflection Limit)and L1180 (Live Load Deflection Limit) and for code
minimum snow load of 25psf. Considering the construction era of the buildings and visual observation of
lumber, we assumed the 6x purlins are of today's Select Structural Grade.
The attached calculations pages Cl and C2 shows the adequacy of 2x decking to support the additional
layer of roofing. Calculation sheets C3 and C4 shows the adequacy of existing purlins to support a dead
load of 15psf and snow load of 25psf.
6775 SW 111th Ave,Suite 20 Beaverton,OR 97008 Tel:503-486-5387;Fax:503-486-5097 www.mgroupengineering.com
Massaad Engineering Group Inc. Page 2 of 2
PART IV-SUMMARY
It is our professional opinion the immediate framing (2x decking and purlin)of the existing roof structure
is capable of supporting the additional weight of the proposed additional layer.
PART V-DISCLAIMER
Recommendations and opinions rendered in this report were conducted with the level of care and
professional judgment ordinarily exercised by members of the professional community currently
practicing in this area under similar information, budget and time constraints. No warranty, implied or
expressed is provided on the structural integrity of the structure as a whole.
Please call our office with any questions or comments.
Respectfully submitted,
Samuel E. Rediske
Project Engineer
Massaad Engineering Group Inc
Reviewed by:
Gaby Massaad, PE, SE
Principal Engineer
�'\�D iNE`ff��
i;/c;Vti FR\.,\.
54520 ?O
7. f B �.q J/
' t, - ✓
U
9 \<<h.=so p
\ems�_MP
EXPIRATION DATE: 12-31-2022
Attachments (SK-1, and C1 thru C4)
6775 SW 111'"Ave,Suite 20 Beaverton, OR 97008 Tel:503-486-5387;Fax:503-486-5097 www.mgroupengineering.com
.^ �... wa"a xy
4a. •
Untitled Mapt : ` .4
,, 't Legend
i ♦ y< K• A!
Write a description for your map. • �4.` �` a°` • ;� ` r �
..• SW Kathenne.S! ...w. '' a .. :.
••
��TF�
�1 Y{ f 4 i nl i Ji't. yw q+.ql S)r 1 xtrp^.'
. 1+
�. 4 i '. r i i". .--.'� f J ti 1.r .^.,ti •�. - rS+" R ye
irk M(_ F, !..• �4
r
e
M•
Y rT R Y`,y. Yf
•
4.
'. Ne
4 ., 3 k„+ kr 4t' ajv
"V! 4 , et f''''' 4 4'4.,,
44,
U • I
•� < 11 > l� ♦a" :" •!
s¢ tie, � 'r ' R,v
r F
.. •.7`..:1V--
fy ` �I S (yam.,��f Jq. \ P
J AV
T y
yy�.
yg . rg #ro' • '� 1' Rua. n
\�! • r4
t�.Ir'yfy
•^ <t `f T '1!� • •t, , A
. 9 � N,c s rr•
f _ irk t (i _ ( w' 3 " Ki'Uf
•
'i' r 't .tr 9 • 1<
A r.::"
oogle Earth :-:14:1
r 300 ft
Project No: 467 04,2.., Sheet: G I
NiGkOUP Project Name: 11.017 — /9//5W )7447(.4,
Massaad Engineering Group Inc, Subject
www.mgroupengineering.com Date: 7/e/24 Engineer: SER
1-ei0006_ 41IL J-Pt
AoF k early
E}UIT/N4- I Ws Z•afsf)
3 y Poclinl4
E)CU?1�4 Z EX/1'T�r,
,''°°"'
I .
i
Akai/As4, 4107,Pole Z,eoet4ir/4 & 20 GIEfit f�
67= /,0x/0 4 _--7-_-, zs-1„/ esitfo
G/4ilr"D gjy Brit/ /'/r 47/ge
at laOtIE G /oet = opst
4,/,rirr�v41 MvU(,cJ 14rf79 = 21,/s1. ICI' 1
/ S E DES / _ i ass'=4
4P�a
C2
Western Woods Use Book 6C.7
Design for TAG and Nall-Laminated Structural Decks
ALLOWABLE LOADS FOR TSAI AND NAIL-LAMINATED STRUCTURAL DECKS Table 6C.1
Allowable Uniformly Distributed Load
SIZE LIMITED BY BENDING LIMITED BY DEFLECTION
Nominal Fb=1000 psi Load, E= 1,000,000 psi Load,psi
Deck Thickness psi Any Layep
(in inches with
weight of decking Combination
In psi) Simple and I Outraged
Simple Span Two Span Two Span Random
(Types I,II,Ili,IV) Deflection Ratio Type I Type II Type III Type IV
` ' - FOOT SPAN continued -
6 e/180 1,437 3,462 2,059 2,171
823 e/240 1,078 1 2,597 1,544 1,628
16 6 psi e1360 719 1,731 1,029 1,085
. • I
2 C/180 20, 47 28.
47 t/240 ' 15' 35 21 19
4.5 psi t/360 10 24 14 13
Immowwsmoomr
3 C/180 90 218 130 137
130 C/240 68 163 97 102
7.6 psi e/360 _ 45 109 65 68
4 e/180 248 598 355 375
255 eJ240 186 448 267 281
10.6 psi t/360 124 299 178 187
6 0180 963 2,319 1,379 1,454
630 1/240 722 1,739 1,034 1,091
16.6 pal l/360 481 1,160 S90 727
2 l/180 14 33 20 18
37 e/240 10 25 15 13
4.5 psi e/360 7 17 10 9
3 t/180 64 159 91 96
103 l/240 48 115 88 72
7.6 psf e/360 32 76 45 48
4 C/180 174 420 250 263
202 l./240 131 315 187 197
10.6 psi 1/360 87 210 125 132
6 l/180 676 1,629 989 1,02'
498 l/240 507 1,222 726 I 765
16.6 psi C/360 338 814 484 5,1
8 e/180 1,549 3,731 2,218 2,339
865 e/240 1,162 2,798 1,664 1,755
22.7 sf
p l/360 774 1,865 1,109 1,170
2 e/180 10 . 24 14 13
30 l/240 8 18 11 10
4.5 psf t/360 5 12 7 7
3 t/180 46 112 66
7.6 psi ( 3 . r� 35 84 50 id.,,
23 56 33
Project Title: 9920 SW Tigard St Re-Root
Engineer:
MGkOUP ' Project ID: MG166
Project Descr.
i Massaad Engineering Group Inc. •
Printed: 7 JUL 2021, 2:58PM
File:t 2124 Catcutel ons.ee6
Wood Beam Software copynghtENERCALC,INC.1983-2020,Bulyd:1220.8.17
Lic.#:KW-06009807 Massaad Engineering Group Inc
DESCRIPTION: Typical 6x14 Purlin
CODE REFERENCES
Calculations per NOS 2018, IBC 2018,CBC 2019,ASCE 7-16
Load Combination Set:ASCE 7-16
Material Properties •
Analysis Method: Allowable Stress Design Fb+ 1,600.0 psi E:Modulus of Elasticity
Load Combination ASCE 7-16 Fb- 1,600.Opsi Ebend-xx 1,600.0ksi
Fc-Prll 1,100.0 psi Eminbend-xi( 580.O ksi
Wood Species : Douglas Fir-Larch . Fc-Pap 625.0 psi
Wood Grade :Select Structural Fv 170.0 psi
Ft 950.0psi Density 31.210pcf
Beam Bracing : Beam is Fully Braced against lateral-torsional buckling
D(0.12)S(0.2)
�.- _. .____ -_.__ 0 --_ 0 --. __ -
•
6x14
•
Span=24.0 ft
Applied Loads Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loads
Uniform Load: 0=0.0150, S=0.0250 ksf, Tributary Width=8.0 ft
DESIGN SUMMARY • Dcsi n OK
Maximum Bending Stress Ratio = 0.94d 1 Maximum Shear Stress Ratio = 0.380 : 1
Section used for this span 6x14 Section used for this span 6x14
fb:Actual = 1,738.18psi fv:Actual = 74.34 psi
Fb:Allowable = 1,840.00psi Fv: Allowable = 195.50 psi
Load Combination +D+S Load Combination +D+S
Location of maximum on span = 12.000ft Location of maximum on span = 0.000ft
Span#where maximum occurs = Span#1 Span#where maximum occurs = Span#1
Maximum Deflection
Max Downward Transient Deflection 0.832 in Ratio= 346>=180
Max Upward Transient Deflection 0.000 in Ratio= 0<180
Max Downward Total Deflection 1.399 in Ratio= 205>=120
Max Upward Total Deflection 0.000 in Ratio= 0<120
Maximum Forces&Stresses for Load Combinations
Load Com.,ination Max Stress Ratios Moment Values Shear Values
Segment Length Span it M V Cd C FN C i Cr Cm C t CL M 1b Fb V fv Fv
D Only 0.00 0.00 0.00 0.00
Length=24.0 ft 1 0.489 0.197 0.90 0.987 1.00 1.00 1.00 1.00 1.00 9.80 703.83 1440.00 1.49 30.10 153.00
+0+S 0.987 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00
Length=24.0 It 1 0.945 0.380 1.15 0.987 1.00 1.00 1.00 1.00 1.00 24.20 1,738.18 1840.00 3.68 74.34 195.50
+040.7505 0.987 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00
Length=24.0 ft 1 0.804 0.324 1.15 0.987 1.00 1.00 1.00 1.00 1.00 20.60 1,479.59 1840.00 3.13 63.28 195.50
+0.60D 0.987 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00
Length=24.0 ft 1 0.165 0.066 1.60 0.987 1.00 1.00 1.00 1.00 1.00 5.88 422.30 2560.00 0.89 18.06 272.00
Overall Maximum Deflections
Load Combination ' Span Max.' Deft Location in Span Load Combination Max.'+'Defl Location in Span
+D+S 1 1.3987 12.088 - 0.0000 0.000
Project Title: 9920 SW Tigard St Re-Roof 6,1
1V1-1-3(3 kOUP
Engineer:
Project ID: MG166
Project Descr:
Massaad Engineering Group Inc.
Printed: 7 JUL 2021. 2:58PM
Wood Beam T : 19 • .uiId: 2.20_.1ts
SoltwarecopyrigM ENEftCALC,INC.79832020,fiuild�72.20.B.17
Lic.#:KW-06009807 Massaad Engineering Group Inc
DESCRIPTION: Typical6x14Purlin
Vertical Reactions Support notation:Far left is#1 Values in KIPS
Load Combination Support 1 Support 2
Overall Mk0mum 4.033 4.033
Overall MINimum 2.400 2.400
D Only 1.633 1.633
+D+S 4.033 4.033
+0+0.7505 3.433 3.433
40.60D 0.980 0.980
S Only 2.400 2.400
LOW SLOPE ROOFING SYSTEM SPECIFICATION
4 Roofing Product - FOUR-PLY CONVENTIONAL 502 (Base Ply & Cap)
System Configuration ROOF DECK/ //. BASE SHEET/
~J M4 AHA(515,2-500,502 cap) COVER BOARD• / MECH.ATTACH OR .
M4-AIA(615,2.506,502 cap) ,'COVER
' //./// FULLYADHERED
M4-BHA(501,'2-500,502 cap) j///j//`/ •/
M4.B1A(501,2-506,502 cap) /////j// �:
Materials per 100 sq./ft.of roof area: //, //
Base Sheet Options(choose one of the following): /// ////
One.(1)ply of 515 25.0 lbs. //////
One(1)ply of 501 30.6 lbs. ////////
/// ///
Ply Sheet Options(choose one of the following); / /// /
Two'(2)plies of 500. 7.2 lbs.per ply/14.4 lbs. / /// ' / ' `
Two(2)plies of 506 9.2 lbs.per ply/18.4 lbs. // // "" —�"
Cap Sheet: ////�
One(1)ply of 502 72.0lbs. ///
Adhesive for roofing plies- ASTM D 312 //
type III,or IV /////
25.0 ibs,per ply/per sq. /j/
Insulation: Specified
/
i'Wg/?t per square(-insulation): 211.4lbs.to 221.0Ibs,, j t
/
Roof deck and general information: Roof deck must be / 2 PLIES CAP SHEET
clean, dry, smooth, and structurally sound to receive the new •
/ FULLY ADHERED>;' FULLYADHERED
roofing system. Drainage must be incorporated in the design „,: +
to prevent ponding water. For more information, please refer Four ply;hot tapped,built-up roofing system wtthconventio al fiber
to the current Malarkey Specification Manual:General require- glass base,ply,and cap sheet Installed over an appipoved roof deck.
ments and Commercial Installation Instructions.
Special requirements: This roofing system can be installed Flashings: Install all primed fleshings(lead, metal,scuppers,
as illustrated on slopes up to 1"in 12". Slopes that are greater etc) in a layer of plastic cement on top of the inter-ply and
than 1" in 12" are to be installed in a strapped fashion using stripped off with Two(2)of reinforcement,feathering each ply
ASTM D 312 type IV asphalt,and wood nailers/insulation stops 3"from the edge of the flange and corresponding ply. Install
to facilitate back nailing of the roofing system. For more in- cap sheet after all fleshings have been stripped in.
formation, please refer to the current Malarkey Specification
Manual:General Requirements/Strapped Installations. Base flashings: Base flashing stripping ply(s)are to be in-
stalled over the inter-ply before the installation of the field sur-
Application:Hot Mopped-install base sheet according to in- facing. Stripping ply(s)are to extend 3"beyond the toe of the
structions in section-4-5 of this manual: Install all inter-plies cant and up the vertical surface of all flat to vertical transitions
so that the water runs over (shingle fashion) or parallel to (curbs,walls, roof top equipment,etc).After the installation of
(strapped),but never against the laps in a uniform mopping of the field surfacing,install the specified cap sheet base flashing
hot asphalt at the nominal rate of 25 lbs. per ply, per square. extending 6"beyond the toe of the cant and up the vertical sur-
Broom all plies to ensure contact between the asphalt and face.Terminate the base flashing as shown in the commercial
the bottom surface of the roofing felts. Cap sheet will be in- roofing details of the current Malarkey Specification Manual.
stalled so that the water runs over(shingle fashion)or parallel
to(strapped), but never against the laps.Cut cap to 1/3 of the Fire Ratings: The specification carries a Class `A' rating up
total length(11')and allow to relax prior to installation. Position to 2" in 12"over the following decks: Wood, Metal, Concrete,
cap membrane for installation and embed into a uniform mop- Lightweight Concrete, Structural Wood Fiber, and Gypsum.
ping of asphalt applied at the rate of 25 lbs.per square.Broom The exact listing for this roofing system can be found in the
all cap sheet to ensure contact between the asphalt and the current edition of the ITS Wamock Hersey Directory of Listed
bottom of the sheet. Stagger all end laps a minimum of 12". Products. For other ratings, contact the Malarkey Technical
Services Department.
Valleys and Waterways: Prior to the application of interply
sheets, all valleys and waterways shall receive an extra layer
of Malarkey ply sheet(or comparable product)which shall be at
least a full width sheet and shall extend at least 12 inches(30
cm)up to the inclines out of the valleys.
- RF1/ 12/11
• TGFU.R4170 - Roofing Systems Page 1 of 13
4101 ONLINE CERTIFICATIONS DIRECTORY .r""
TGFU.R4170
Roofing Systems
Page bottom
Roofing Systems
See General Information for Roofing Systems
MALARKEY ROOFING PRODUCTS R4170
3131 N COLUMBIA BLVD
KENTON STATION
PO BOX 17217
PORTLAND,OR 97217-0217 USA
Unless otherwise indicated the"501 or 503 Modified Base"Is interchangeable with"515 Base". 500 Ply 4 and 506 Ply 6 are also interchangeable.
Unless otherwise indicated,vapor retarders,base or ply sheets are optional beneath roof insulation on all roof systems.
Unless otherwise Indicated, roof insulation and base sheets may be mechanically fastened to the deck with screws and metal or plastic discs; hot
roofing asphalt or a combination of screws/discs and hot roofing asphalt.
UL Classified Insulation adhesive may be used in any of the following Classifications to adhere uniform or tapered roof insulation(excluding
polystyrenes)in any thickness or combination, (provided they do not exceed the Indicated incline or thickness)to non-combustible roof deck
substrates and other insulation layers Including wood fiberboard,G-P Gypsum Corp. "DensDeck®Roofboard"or"DensDeck Prime®Roofboard"
or"DensDeck DuraGuard"Roofboard"and 1/4, 3/8, 1/2 or 5/8 in.thick"SECUROCK"Roof Board(Type FRX-G)".
Any noncombustible deck Classification incorporating polyisocyanurate insulation may substitute the polyisocyanurate with EPS covered by a layer
of 1/2-in.thick(min)wood fiberboard,3/4-in.thick(min)periite board or 1/4-in. (min)G-P Gypsum"DensDeck®,""DensDeck Prime®,"or
"DensDeck DuraGuard®"or 1/4,3/6, 1/2 or 5/8 in. thick"SECUROCK"Roof Board (Type FRX-G)".Classification(A,B or C)and maximum
incline limited to membrane manufacturer's Insulated or non-insulated roofing systems(TGFU)Certifications. NOTE: "SECUROCK'"Roof Board
(Type FRX-G)"Is limited to incline not to exceed 3-in and limited to current TGFU-R4615 File Notes.
(Optional)Noncombustible deck Classifications are applicable for use over cobmbustible(15/32 in.min plywood)decks when 1/2 in. (min)gypsum
board; 1/4-in. (min)G-P Gypsum"DensDeck®,""DensDeck Prime®,"or"DensDeck DuraGuard®"1/4 in. (min)"G-P Gypsum DensDeck®"are
used directly over the deck with all joints staggered 6 in.(min)from plywood joints. Classification(A,B or C)and maximum incline limited to •
membrane manufacturer's insulated or non-insulated roofing systems(TGFU)Certifications.
The following base sheets are equivalent and may either be adhered with hot asphalt(15-25 lb/sq)or be mechanically fastened:
a)"501 Modified Base"
b)"503 Modified Base"
c)"515 Base"
The following ply sheets are equivalent and may either be adhered with hot asphalt(15-25 lb/sq)or be mechanically fastened:
a) "500 Ply 4"
b)"506 Ply 6"
Unless otherwise indicated,references to Type G2 base sheets also may include base/ply sheets"501 Modified Base""503 Modified Base""515
Base"in any of the following Classifications below.
Type G3 fiberglass reinforced cap sheet("502 Cap")may be used(inverted)in lieu of the Type G2 base sheet in any of the Classifications below.
Unless otherwise indicated,in any of the following Classifications that reference to Type G1 would include ply sheets"500 Ply 4"and"506 Ply 6".
Unless otherwise Indicated,references to Type G3 include cap sheets"502 Cap",hot mopped.
The fiberglass reinforced cap sheet"350 GR"may be used(Inverted)in lieu of the Type G2 base sheet in any of the Classifications below.
The fiberglass reinforced base sheet"Henry 607"may be used in lieu of the Type G2 base sheet in any of the Classifications below.
Class A,B or C
1. Deck:NC Incline:See Note 1
Insulation(Optional):—Any Classified,any thickness.
Barrier Board:— 1/4,3/8, 1/2 or 5/8-in.thick SECUROCK"Roof Board(Type FRX-G), mechanically fastened.
Membrane:—Any modified bitumen system,cold-applied or hot-mopped BUR systems,fluid applied systems,spray applied foam and
coating systems or CPE,CSM,CSPE, PIB, NBP,TRE,EPDM,TPO or PVC single ply membrane system suitable for use with any roof
insulation Classified under Roofing Systems(TGFU).
2.Deck:C-15/32 Incline: 1 max. (Also See Note 1)
httn://database.ul.com/cgi-hin/XYV/temnlate/E,TSFXT/1 FRAMF/shownafre.html?name=T__ 3/21/2016
• TGFU.R4170 - Roofmg Systems Page 2 of 13
Insulation(Optional): —Any Classified,any thickness.
Barrier Board:— 1/2 or 5/8-in.thick SECUROCK'Roof Board(Type FRX-G),mechanically fastened with all butt joints staggered a
minimum of 6 in.from the plywood deck joint.
Membrane:—Any modified bitumen system,fluid applied systems,spray applied foam and coating systems or CPE,CSM,CSPE, PIB,
NBP,TRE,EPDM,TPO or PVC single ply membrane system suitable for use with any roof insulation Classified under Roofing Systems
(TGFU).
3. Deck:C-15/32 Incline:See Note 2
Insulation(Optional):—Any UL Classified,any thickness.
Barrier Board:— 1/4, 3/8, 1/2 or 5/8 in.thick SECUROCK"^Roof Board(Type FRX-G)with all barrier board butt joints staggered a
minimum of 6 in.from the plywood deck butt joints.
Membrane:—Any cold-applied or hot-mopped BUR systems suitable for use with any roof insulation Classified under Roofing Systems
(TGFU).
4. Deck:C-15/32 Incline:See Note 2
Base Sheet: —One ply Type G2 mechanically attached.
Insulation(Optional):—Any UL Classified,any thickness.
Barrier Board:— 1/4,3/8, 1/2 or 5/8 In.thick SECUROCK'"Roof Board(Type FRX-G)with all barrier board butt joints staggered a
minimum of 6 in.from the plywood deck butt joints.
Membrane:—Any modified bitumen system,fluid applied systems,spray applied foam and coating systems or CPE,CSM,CSPE, PIB,
NBP,TRE,EPDM,TPO or PVC single ply membrane system suitable for use with any roof insulation Classified under Roofing Systems
(TGFU). When the Classified roof-covering system consists of single or multiple plies of base/ply sheets with a total minimum glass
reinforcement weight of 1.0 lbs per 100 ft2,the use of the Type G2 base sheet is optional.
5. Deck:C-15/32 Incline:See Note 2
Barrier Board:—(See Note 3)— 1/4,3/8, 1/2 or 5/8 in.thick SECUROCK'"Roof Board (Type FRX-G)with all barrier board butt joints
staggered a minimum of 6 in.from the plywood deck butt joints.
Insulation(Optional):—Fiberglass,polyisocyanurate,perlite or wood fiber,any thickness.
Membrane:—Any cold-applied or hot-mopped BUR systems suitable for use over the types of insulation specified above Classified under
Roofing Systems(TGFU).
6. Deck:C-15/32 Incline:See Note 2
Base Sheet:—One ply Type G2 mechanically attached.
Barrier Board:—(See Note 4) — 1/4, 3/8, 1/2 or 5/8 In.thick SECUROCK'"Roof Board(Type FRX-G)with all barrier board butt joints
staggered a minimum of 6 in.from the plywood deck butt joints.
Insulation(Optional):—Fiberglass,polyisocyanurate,perlite or wood fiber,any thickness.
Membrane:—Any modified bitumen system,fluid applied systems,spray applied foam and coating systems or CPE,CSM,CSPE, PIB,
NBP,TRE,EPDM,TPO or PVC single ply membrane system suitable for use over the types of insulation specified above Classified under
Roofing Systems(TGFU).When the Classified roof-covering system consists of single or multiple plies of base/ply sheets with a total
minimum glass reinforcement weight of 1.0 lbs per 100 ft2,the use of the Type G2 base sheet is optional. •
7. Deck:C-15/32 Incline:See Note 2
Insulation:—Fiberglass,polyisocyanurate,perlite or wood fiber, (UL Classified,any thickness).
Barrier Board:— 1/4, 3/8, 1/2 or 5/8 in.thick SECUROCK'"Roof Board(Type FRX-G)with all barrier board butt joints staggered a
minimum of 6 in.from the plywood deck butt joints.
Membrane:—Any modified bitumen system,fluid applied systems,spray applied foam and coating systems or CPE,CSM,CSPE,PIB,
NBP,TRE,EPDM,TPO or PVC single ply membrane system suitable for use with any roof insulation Classified under Roofing Systems
(TGFU).
8. Deck:C-15/32 Incline:See Note 5
Barrier Board:— 1/4,3/8, 1/2 or 5/8 In.thick SECUROCK'"Roof Board(Type FRX-G)with all barrier board butt joints staggered a
minimum of 6 in. from the plywood deck butt joints.
Insulation:—Fiberglass,polyisocyanurate, perlite or wood fiber, (UL Classified,any thickness).
Membrane: —Any modified bitumen system,fluid applied systems,spray applied foam and coating systems or CPE,CSM,CSPE,PIB,
NBP,TRE, EPDM,TPO or PVC single ply membrane system suitable for use over the types of insulation specified above Classified under
Roofing Systems(TGFU).
Note 1: Classification(A,B or C)and maximum incline limited to membrane manufacturer's insulated or non-Insulated roofing systems
(TGFU)Certifications.
Note 2: Classification (A,B or C)and Incline limited to membrane manufacturer's insulated or non-insulated roofing systems(TGFU)
Certifications but incline is not to exceed 3-in.
Note 3: The use of SECUROCK'" Roof Board(Type FRX-G)as a barrier board directly over the combustible deck permits the use of any
Classified Roofing System(TGFU)which otherwise is limited to use over noncombustible deck.When used,the insulation must consist of
one of the types specified.
Note 4:The use of a Type G2 base sheet and SECUROCK'' Roof Board(Type FRX-G)as a barrier board directly over the combustible
deck permits the use of any Classified Roofing System(TGFU)which otherwise is limited to use over noncombustible deck.When used,
the insulation must consist of one of the types specified.
Note 5: Classification(A,B or C)and incline limited to membrane manufacturer's insulated roofing systems(TGFU)Certifications but
incline is not to exceed 3-in.
Class A-Ballasted
1. Deck:C-15/32 Incline: 1
httn•/Matahase nl.enm/ecri-hin/XVV/temnlate/T,TSRXT/1 FRAMF/showna¢e.html?name=T... 3/21/2016
• TGFU.R4170 - Roofing Systems Page 3 of 13
Insulation(Optional):—Any UL Classified polyisocyanurate insulation,any thickness,one or more layers"Fesco"or"DuraBoard",
"Fesco-Foam","Fiber Glass Roof Insulation","ISO 3","ENRGY 3"or hot mopped or mechanically fastened in combination (optional)with
1/2 in. "Retro-Fit"cover board or wood fiberboard,or 3/4 in. "Fesco"or"DuraBoard"over polystyrene.
Base Sheet:—One ply Type GI or"500 Premium Ply 4"and"506 Ply 6",or Type G2 or"501 Modified Base""503 Modified Base Sheet"
"515 Base", mechanically fastened or hot mopped.
Ply Sheet:—Two or more plies Type G1 or"500 Ply 4"and"506 Ply 6,hot mopped.
Surfacing:—River bottom stone(3/4 to 1-1/2-In die.)at 1000 lbs/sq or concrete pavers at 10 lbs/sq spaced a max of 1/8-in.apart).
2. Deck:C-15/32 Incline:3
Insulation(Optional):—Any UL Classified polyisocyanurate Insulation,any thickness,one or more layers"Fesco"or"DuraBoard",
"Fesco-Foam","Fiber Glass Roof Insulation","ISO 3", "ENRGY 3"or hot mopped or mechanically fastened in combination (optional)with
1/2 in. "Retro-Fit"cover board or wood fiberboard,or 3/4 in."Fesco"or"DuraBoard"over polystyrene.
Ply Sheet:—Three or more piles Type G1 or"500 Ply 4",or"506 Ply 6",nailed or hot mopped.
Surfacing:—River bottom stone(3/4 to 1-1/2-in dia.)at 1000 lbs/sq or concrete pavers at 10 lbs/sq spaced a max of 1/8-In. apart).
Class B-Ballasted
1, Deck:C-15/32 Incline:3
Base Sheet:—Type G2.
Membrane:—"163 Omni TG Smooth", "162 Omni TG Granular","160 Omni Ultra Smooth"heat welded.
Surfacing: —Gravel,embedded in hot mopping asphalt or heat fused.
ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT
Unless otherwise indicated,Trumbull"Perma Mop°is an acceptable alternate for hot roofing asphalt in any of the following roofing systems.
Class A
"515 Base"is an acceptable alternate to any Type G2 base sheet in any Classification.
1. Deck:C-15/32 Incline:3
Insulation:—Perlite,glass fiber or OCF composite glass fiber/urethane,3-1/2 in. max, nailed or hot mopped.
Base Sheet(Optional):—Type G2 or"508 Modified Venting Base",hot mopped.
Ply Sheets: 1 to 3 layers"515 Base"or Type G2 or"501 Modified Base",hot mopped.
Surfacing:—Gravel.
2. Deck:C-15/32 Incline: 1/2
Base Sheet:—Type G2 or"515 Base",mechanically fastened.
Ply Sheet:—One or more plies Type G2 or"515 Base", hot mopped.
Surfacing:—Type G3"502 Cap",hot mopped.
3. Deck:C-15/32 Incline: 3
Base Sheet: —"515 Base"or Type G2 or"501 Modified Base".
Ply Sheet: — 1 or 2 layers Type G2 or"515 Base".
Surfacing: —Gravel.
4. Deck: NC Incline:2
Insulation(Optional):—Perlite,glass fiber or OCF glass fiber/urethane composite,3-3/4 in.max, mechanically fastened or hot
mopped.
Base Sheet(Optional):—Type G2 or"508 Modified Venting Base".
Ply Sheet:—1 or 2 layers Type G1"500 Ply 4".
Surfacing:—Type G3"502 Cap",hot mopped.
5. Deck:C-15/32 Incline:2
Insulation:—Glass fiber or OCF glass fiber/urethane composite, 1 to 3-3/4 in. mechanically fastened or hot mopped.
Ply Sheet:—2 or more layers Type G2 or"515 Base"or"501 Modified Base"hot mopped.
Surfacing:—Type G2 or G3"502 Cap",hot mopped.
6. Deck:NC Incline:3
Base Sheet:—Type G2 or"515 Base",mechanically fastened or hot mopped.
Ply Sheet:— 1 or more layers Type GI "500 Ply 4",hot mopped.
Surfacing:—Gravel.
7. Deck: C-15/32 Incline: 1
Insulation(Optional):—Any UL Classified polyisocyanurate insulation,any thickness,one or more layers"Fesco"or"DuraBoard",
"Fesco-Foam", "Fiber Glass Roof Insulation", "ISO 3", "ENRGY 3"or hot mopped or mechanically fastened in combination(optional)with
1/2 In. "Retro-Fit"cover board,or 3/4 In. "Fesco"or°DuraBoard"over polystyrene.
Base Sheet:—One ply Type G1 or"500 Ply 4"and"506 Ply 6",or Type G2 or"501 Modified Base"or"503 Modified Base"or"515
Base", mechanically fastened or hot mopped.
Ply Sheet:—Two or more plies Type G1 or"500 Ply 4"and"506 Ply 6, hot mopped.
Surfacing:—Gravel or crushed stone at 400 lbs/sq or slag at 300 lbs/sq embedded into hot roofing asphalt.
8. Deck:C-15/32 Incline:3
lion°//clatahaSP.nl cnm/cai-hin/XYV/temnlate/i.TSFXT/1 FR AMF/shnwnaoe html9name=T... 3/21/201 Fi
TGFU.R4170 - Roofing Systems Page 4 of 13
Insulation(Optional):—Any UL Classified polyisocyanurate insulation,any thickness,one or more layers"Fesco"or"DuraBoard",
"Fesco-Foam","Fiber Glass Roof Insulation","ISO 3","ENRGY 3"or hot mopped or mechanically fastened in combination(optional)with
1/2 in. "Retro-Fit"cover board,or 3/4 In."Fesco"or"DuraBoard"over polystyrene.
Ply Sheet:—Three or more plies Type G1 or"500 Ply 4"or"506 Ply 6",nailed or hot mopped.
Surfacing:—Gravel or crushed stone at 400 lbs/sq or slag at 300 lbs/sq embedded into hot roofing asphalt.
9. Deck: NC Incline: 1-1/2
Insulation(Optional): —Any UL Classified polyisocyanurate Insulation,any thickness,one or more layers"Fesco"or"DuraBoard",
"Fesco-Foam", "Fiber Glass Roof Insulation", "ISO 3", "ENRGY 3"or hot mopped or mechanically fastened In combination(optional)with
1/2 in. "Retro-Fit"cover board or wood fiberboard,or 3/4 in."Fesco"or"DuraBoard"over polystyrene.
Base Sheet:—Type G2 or"501 Modified Base"or"503 Modified Base"or"515 Base"or Johns Manville"PermaPly 28"or"Ventsulation"
mechanically fastened or hot mopped.
Ply Sheet(Optional): —Two or more plies Type G1 or"500 Ply 4"and"506 Ply 6",mechanically fastened or hot mopped.
Surfacing: —"502 Cap",hot mopped.
10. Deck: NC Incline: 1-1/2
Insulation(Optional):—Any UL Classified polyisocyanurate insulation,any thickness,one or more layers"Fesco"or"DuraBoard",
"Fesco-Foam","Fiber Glass Roof Insulation","ISO 3","ENRGY 3"or hot mopped or mechanically fastened in combination(optional)with
1/2 in. "Retro-Fit"cover board or wood fiberboard,or 3/4 In."Fesco"or"DuraBoard"over polystyrene.
Base Sheet(Optional):—Type G2 or"501 Modified Base"or"503 Modified Base"or"515 Base"or Johns Manville"PermaPly 28"or
"Ventsulation"mechanically fastened or hot mopped.
Ply Sheet:—Two or more plies Type G1 or"500 Ply 4"and "506 Ply 6",mechanically fastened or hot mopped.
Surfacing:—Type G3"502 Cap",hot mopped.
11. Deck:C-15/32 Incline: 1
Insulation(Optional):—Any UL Classified polylsocyanurate insulation,any thickness,one or more layers"Fesco"or"DuraBoard",
"Fesco-Foam","Fiber Glass Roof Insulation", "ISO 3", "ENRGY 3"or hot mopped or mechanically fastened in combination(optional)with
1/2 in. "Retro-Fit"cover board or 3/4 in."Fesco"or"DuraBoard"over polystyrene.
Base Sheet: —One ply Type G1 or"500 Ply 4"and"506 Ply 6"or Type G2 or"501 Modified Base"or"503 Modified Base", "515 Base"or
Johns Manville"Ventsulation",mechanically fastened or hot mopped.
Ply Sheet:—Two or more plies Type G1 or"500 Ply 4"and"506 Ply 6",mechanically fastened or hot mopped.
Surfacing:—Type G3"502 Cap",hot mopped.
12.Deck:NC Incline: 1
Insulation:—Any thickness, one or more layers,any UL Classified perlite,fiber glass,wood fiberboard,polyisocyanurate,
polyisocyanurate/perlite composite,hot mopped, mechanically attached or cold adhesive.
Base Sheet:—"500 Ply 4"and"506 Ply 6",or Type G2 or"501 Modified Base"or"503 Modified Base"or"515 Base"or Johns Manville
"Ventsulatlon",mechanically fastened or hot mopped.
Ply Sheet:—One or more plies of"501 Modified Base Sheet,""503 Modifed Base","500 Ply 4,"and"506 Ply 6"hot mopped.
Surfacing:—Type G3"502 Cap",hot mopped.
13.Deck:NC Incline: 1
Base Sheet: —Type G2 or"501 Modified Base"or"503 Modified Base"or"515 Base"or Johns Manville"PermaPly 28","GlasBase"or
"Ventsulation",mechanically fastened or hot mopped.
Ply Sheet:—One or more plies of"501 Modified Base"or"503 Modified Base",hot mopped.
Surfacing:—Type G3"502 Cap", hot mopped.
14. Deck:C-15/32 Incline: 2
Base Sheet:—Type G2 or"501 Premium Modified Base"or"503 Modified Base"or"515 Base"or Johns Manville"GlasBase"or
"Ventsulation",mechanically fastened or hot mopped. •
Insulation—Any thickness,one or more layers"Fesco"or"DuraBoard"(must be 1 in.min at 1 in.incline),"Fesco-Foam","Fiber Glass
Roof Insulation", "ISO 3","ENRGY 3"or any UL Classified polyisocyanurate,hot mopped or mechanically fastened, in combination
(optional)with 1/2 In. "Retro-Fit"cover board,or 3/4 In. "Fesco"or"DuraBoard"over polystyrene.
Ply Sheet:—Two or more plies Type G1 or"500 Ply 4"and"506 Ply 6".
Surfacing:—Type G3"502 Cap",hot mopped.
15.Deck:NC Incline:2
Base Sheet(Optional):—Type G2 or"501 Modified Base"or"503 Modiefied Base"or"515 Base"or Johns Manville"GlasBase"or
"Ventsulation",mechanically fastened or hot mopped.
Insulation: —Any thickness,one or more layers"Fesco"or"DuraBoard"(must be 1 in. min at 1 in. incline),"Fesco-Foam","Fiber Glass
Roof Insulation", "ISO 3","ENRGY 3"or any UL Classified polylsocyanurate,hot mopped or mechanically fastened,in combination
(optional)with 1/2 in. "Retro-Fit"cover board or wood fiberboard,or 3/4 in."Fesco"or"DuraBoard"over polystyrene.
Ply Sheet:—Two or more plies Type G1 or"500 Ply 4"and"506 Ply 6"or Type G2"501 Modified Base""503 Modified Base""515 Base",
hot mopped.
Surfacing:—Type G3"502 Cap",hot mopped.
Class B
1. Deck:NC Incline:3
Insulation(Optional):—Insulation(Optional): —Any UL Classified polyisocyanurate insulation, hot mopped or mechanically fastened
in combination(optional)with 1/2 in. "Retro-Fit"cover board or wood fiberboard,or 3/4 in."Fesco"or"DuraBoard"over polystyrene.Any
thickness,one or more layers"Fesco"or"DuraBoard","Fesco-Foam", "Fiber Glass Roof Insulation","ISO 3"or"ENRGY 3".
Ply Sheet:—Two or more plies Type G1 or"500 Ply 4"and"506 Ply 6", mechanically fastened or hot mopped.
Surfacing:—Type G3"502 Cap",hot mopped.
httro://database.ul.com/cei-hin/XYV/temnlate/LISEXT/1 FRAME/shownaae.html?name=T... 3/21/2016
•
• TGFU.R4170 - Roofing Systems Page 5 of 13
2, Deck:C-15/32 Incline:No Limitation Messrawiwiterorwoo
Base Sheet(Optional):—Type G2 or"501 Modified Base"or"503 Modified Base"or"515 Base"or Johns Manville"GlasBase",
mechanically attached or hot mopped.
Ply Sheet:—Two or more plies Type G1 or"500 Ply 4"and"506 Ply 6",mechanically fastened or hot mopped.
Surfacing:—Type G3"502 Cap",hot mopped.
COMBINATION HOT AND COLD SYSTEMS
Class A
1. Deck: NC Incline: 1-1/2
Insulation:—Glass fiber, perlite or wood fiber 1 in., mechanically fastened or hot mopped.
Ply Sheet:—2 or more layers Type G1 "500 Ply 4", hot mopped.
Surfacing:—"Fibered Asphalt Emulsion",3 gal/sq
2. Deck: NC Incline:3/4
Insulation: —Glass fiber,perlite or wood fiber 1 in., mechanically fastened or hot mopped.
Ply Sheet:—2 or more layers Type G1 "500 Ply 4", hot mopped.
Surfacing: — "Fibered Aluminum Roof Coating",2 gal/sq
Class B
1. Deck:C-15/32 Incline: 1/2
Insulation: —Perlite glass fiber,wood fiber or R-Max"Standard"polyisocyanurate 1-3 in.,mechanically fastened or hot mopped.
Ply Sheet: —3 layers Type G1 "500 Ply 4".
Surfacing:— "Fibered Asphalt Emulsion",3 gal/sq
COLD APPLICATION SYSTEMS
Class A
1. Deck:C-15/32 Incline: 1-1/2
Classified Roof System:—Any Class A, B or C,coated or uncoated,insulated or uninsulated,smooth surfaced,Type G3 mineral
surfaced cap sheet BUR system.
Base Coat:—"Henry 107 Asphalt Emulsion", 2 to 3 gal/sq(1 application).
Top Coat:—"Henry 280DC White Elastomeric Roof Coating"applied 1 to 1-1/2 gal/sq/application.
Surfacing:—"Henry 280DC White Elastomeric Roof Coating"applied at 1 to 1-1/2 gal/sq/application.
2. Deck:C-15/32 Incline: 1-1/2 •
Classified Roof System:—(To maintain existing Classifications)-Any Class A,B or C,coated or uncoated, insulated or uninsulated,
smooth surfaced,Type G3 mineral surfaced cap sheet BUR system.
Base Coat:—"Henry 107 Asphalt Emulsion",2 to 3 gal/sq (1 application).
Top Coat:—"Henry 291 Premium Elastomeric Base Coating"applied 1 to 1-1/2 gal/sq/application.
Surfacing:— "Henry 280DC White Elastomeric Roof Coating"applied at 1 to 1-1/2 gal/sq/application.
3. Deck:C-15/32 Incline: 1
Classified Roof System: —(To maintain existing Classifications)-Any Class A,B or C,uncoated,insulated or uninsulated,Type G3
mineral surfaced cap or mineral surfaced modified bitumen membrane BUR system.
Base Coat(Optional):—"Henry 107 Asphalt Emulsion",2 to 3 gal/sq(1 application).
Top Coat:— "Henry 280DC White Elastomeric Roof Coating"applied at 1 to 1-1/2 gal/sq/application.
Surfacing:—"Henry 280DC White Elastomeric Roof Coating"applied at 1 to 1-1/2 gal/sq/application.
4. Deck:C-15/32 Incline: 1/2
Classified Roof System: —(To maintain existing Classifications)-Any Class A,B or C, uncoated,insulated or uninsulated,Type G3
mineral surfaced cap or modified bitumen membrane BUR systems.
Surfacing:—"APOC 252 Sunwhite FR",2 coats at 1.5 gal/sq per coat.
5. Deck:NC Incline: 1/4
Insulation: —Polyisocyanurate,glass fiber, wood fiber or perlite,any thickness,mechanically fastened.
Base Sheet:—One or more layers Type G1 or G2,hot mopped in place.
Membrane:—Any UL Classified SBS or APP modified bitumen membrane,hot mopped or heat fused.
Surfacing:—Kamak"#298", 1-1/2 gal sq
6. Deck:C-15/32 Incline: 1/2
Insulation(Optional):—Any UL Classified polyisocyanurate insulation,any thickness,one or more layers"Fesco"or"DuraBoard","
Fesco-Foam", "Fiber Glass Roof Insulation", "ISO 3", "ENRGY 3"or hot mopped or mechanically fastened in combination(optional)with
1/2 In. "Retro-Fit"cover board,or 3/4 In. "Fesco"or"DuraBoard"over polystyrene.
Base Sheet:—One ply Type GI or"500 Ply 4"and "506 Ply 6",or Type G2 or"501 Modified Base"or"503 Modified Base"or"515 Base
",mechanically fastened or hot mopped.
Ply Sheet: —Two or more plies Type G1 or"500 Ply 4"and"506 Ply 6,hot mopped.
Surfacing:—Crushed stone at 400 lbs/sq or slag at 300 lbs/sq embedded into Soprema"FM Adhesive(VOC)"at 3-4 gals/sq
httn://datahase.ul.com/cgli-hin/XYV/temnlate/i.1SFXT/1 FRAMF/shownage.html?name=T... 3/21/2016