Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
OFFICE COPYRECEIVEL 7 2-U -CDQ5S AU6 17 2021 i toss S21/ (d9`� -Ate • t.:ITY OF TIGARD BUILDING DIVISION SPRINKIT FIRE PROTECTION DURHAM O& M BU I L I,, G / SW 85th Avenue r / �' 1.77506 PE Tigard, Or 97224 8-13-2021 OREGON 'Pk Jq 0 Y p EXPIRATION DATE: 12'31/2022 HYDRAULIC CALCULATIONS AND SUBMITALS BY: Sprinklt Fire Protection Inc. PO 2227 Oregon City, OR 97045 PHONE: 503-272-6650 CCB# 211320 t 5 - �1 1 :� . , . i1 I�' r T Mt i ( I 1 .++�.. .•.., • f-ow . --' , - �k4 � � ,,Y R r- . ., l ; *. �Aap —,���f fop �r �14E- r' l� li i • * 4:414,Hte. 0 el'ot: ' d I I ' 'ft i ;41' 0 - i 4 !� f i � "F` y R = C //JJ Sr �p! tc-- a R s,A.* or,.. �r 'a ..l w'L` r. ....: r mac, Y �4ak -. , 4 f ¢, d . • i4 • ::,,,,ik- + ` x , . 1 ► � R 'I � �t <' S 4. I. xtre 44 FW'Zf•s N' ; fi.� r ri E. 2, A` N 1 • a • '1,. ' \ EXEC , _ 1 i4 412 ( _ �r{� a16 d ib- �yy . f q k, 1. ia-=1x0_i,, I'F -I.. ` A 1 Hydraulic Calculations by HydraCALC SPRINKIT FIRE PROTECTION PO BOX 2227 OREGON CITY OREGON 97045 cArAll4 ffinlil ' /r I 77506 PE 8-13-2021 Job Name : Durham 0 & M OREGON Drawing : 1 ti Location : TIGARD, OR Grp �4 N 10 1o°�.�Q' Remote Area 1 Y L O Contract Data File : Durham -7-31-21 Area 1.WXF EXPIRATION DATE:12/31/2022 Computer Programs by Hydratec Inc. Revision: 50.5520.727 SPRINKIT FIRE PROTECTION Page 1 Durham O & M Date 8-11-21 HYDRAULIC CALCULATIONS for JOB NAME DURHAM O&M MAINTENANCE STORAGE Location TIGARD, OR Drawing# 1 Contract# Date 8/10/21 DESIGN Remote area# 1 Remote area location NEW LARGE CANOPY Occupancy classification OH II Density 0.2-Gpm/SqFt Area of application 1620- SqFt Coverage/sprinkler 100 - SqFt Type of sprinkler calculated TY3131 5.6-K UP #Sprinklers calculated 20 In-rack demand n/a- GPM Hose streams 250 -GPM Total water required(including hose streams) 705.326-GPM @ 69.162 - Psi Type of system DRY Volume of system(dry or pre-action) 223- Gal WATER SUPPLY INFORMATION Test date 6/7/18 Location EXISTING CITY MAIN Source of info WYATT FIRE PROTECTION CONTRACTOR INFO SPRINKIT FIRE PROTECTION Address PO BOX 2227/OREGON CITY/OREGON 97045 Phone# Name of designer Authority having jurisdiction CITY OF SALEM NOTES: textl(35) - invisible Computer Programs by Hydratec Inc. Revision: 50.5520.727 Water Supply Curve SPRINKIT FIRE PROTECTION Page 2 Durham 0 & M Date 8-11-21 City Water Supply: Demand: C1 -Static Pressure : 98 D1 - Elevation : 6.345 C2- Residual Pressure: 76 D2- System Flow : 455.326 C2- Residual Flow : 1764 D2- System Pressure : 69.162 Hose ( Demand ) : 250 D3- System Demand : 705.326 Safety Margin : 24.802 150 140 130 P 120 R 110 E 100 Cl S 90 S 80 C2 D2 e-- U 70 / ,_, : :0 D3 0 40 30 20 10 D1 200 400 600 800 1000 1200 1400 1600 1800 FLOW( N ^ 1.85) Computer Programs by Hydratec Inc. Revision: 50.5520.727 Fittings Used Summary SPRINKIT FIRE PROTECTION Page 3 Durham 0 & M Date 8-11-21 Fitting Legend Abbrev. Name % % 1 1% 1% 2 2% 3 3'h 4 5 6 8 10 12 14 16 18 20 24 Dvk Dry Viking F1 3 5 49 E NFPA 13 90'Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45'Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA 13 90'Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with*. The fittings marked with a*show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a*will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.5520.727 Pressure / Flow Summary - STANDARD SPRINKIT FIRE PROTECTION Page 4 Durham 0 & M Date 8-11-21 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 1 14.65 5.6 12.65 na 19.91 0.2 75 7.0 2 14.65 5.6 12.76 na 20.0 0.2 100 7.0 3 14.65 5.6 13.29 na 20.41 0.2 100 7.0 4 14.65 5.6 14.43 na 21.27 0.2 100 7.0 5 14.65 5.6 15.9 na 22.33 0.2 100 7.0 6 14.65 17.56 na 7 14.07 20.76 na 8 14.05 21.25 na 9 14.02 22.34 na 10 13.99 24.23 na 32 13.26 46.85 na TOR 13.26 61.27 na UG 1.0 67.08 na TEST 0.0 69.16 na 250.0 11 14.67 5.6 16.12 na 22.48 0.2 84 7.0 12 14.67 5.6 16.43 na 22.7 0.2 84 7.0 13 14.67 5.6 17.35 na 23.33 0.2 84 7.0 14 14.67 18.97 na 15 14.09 20.59 na 17 14.63 5.6 16.76 na 22.93 0.2 100 7.0 18 14.63 5.6 16.95 na 23.06 0.2 100 7.0 19 14.63 5.6 17.64 na 23.52 0.2 100 7.0 20 14.63 5.6 18.74 na 24.24 0.2 100 7.0 21 14.63 20.11 na 22 14.6 5.6 16.42 na 22.69 0.2 100 7.0 23 14.6 5.6 16.61 na 22.82 0.2 100 7.0 24 14.6 5.6 17.28 na 23.28 0.2 100 7.0 25 14.6 5.6 18.36 na 23.99 0.2 100 7.0 26 14.6 19.7 na 27 14.58 5.6 17.68 na 23.54 0.2 100 7.0 28 14.58 5.6 17.86 na 23.67 0.2 100 7.0 29 14.58 5.6 18.53 na 24.11 0.2 100 7.0 30 14.58 5.6 19.98 na 25.03 0.2 100 7.0 31 14.58 21.42 na The maximum velocity is 17.5 and it occurs in the pipe between nodes 10 and 32 Computer Programs by Hydratec Inc. Revision: 50.5520.727 Final Calculations : Hazen-Williams SPRINKIT FIRE PROTECTION Page 5 Durham 0 & M Date 8-11-21 Node1 Elev1 K Ca Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact at Act Eqiv Len Total PfIFt Pf *EQUIVALENT KS *REMOTE HEAD TO SUPPLY 1 14.65 5.60 19.91 1.5 6.000 100 12.646 to 0.0 2 14.65 19.91 1.682 6.000 0.0182 0.109 Vel= 2.87 2 14.65 5.60 20.00 1.5 8.080 100 12.755 to 0.0 3 14.65 39.91 1.682 8.080 0.0657 0.531 Vel= 5.76 3 14.65 5.60 20.42 1.5 8.080 100 13.286 to 0.0 4 14.65 60.33 1.682 8.080 0.1410 1.139 Vel= 8.71 4 14.65 5.60 21.27 1.5 5.990 100 14.425 to 0.0 5 14.65 81.6 1.682 5.990 0.2466 1.477 Vel= 11.78 5 14.65 5.60 22.33 1.5 E 3.533 0.760 100 15.902 to 3.533 0.0 6 14.65 103.93 1.682 4.293 0.3857 1.656 Vel= 15.01 6 14.65 0.0 1.5 T 7.065 0.580 100 17.558 to 7.066 0.251 7 14.07 103.93 1.682 7.646 0.3858 2.950 Vel = 15.01 7 14.07 68.51 3 12.330 100 20.759 to 0.009 8 14.05 172.44 3.26 12.330 0.0392 0.483 Vel= 6.63 8 14.05 93.75 3 12.330 100 21.251 to 0.013 9 14.02 266.19 3.26 12.330 0.0876 1.080 Vel= 10.23 9 14.02 92.79 3 12.330 100 22.344 to 0.013 10 13.99 358.98 3.26 12.330 0.1523 1.878 Vel= 13.80 10 13.99 96.35 3 2E 13.428 66.490 100 24.235 to T 14.388 27.816 0.316 32 13.26 455.33 3.26 94.306 0.2364 22.295 Vel = 17.50 32 13.26 0.0 4 2E 18.795 205.700 100 46.846 to 18.795 0.0 TOR 13.260 455.33 4.26 224.495 0.0642 14.421 Vel = 10.25 TOR 13.260 0.0 6 G 3.772 12.260 120 61.267 to Dvk 61.61 65.382 5.310 UG 1 455.33 6.357 77.642 0.0065 0.507 Vel = 4.60 UG 1 0.0 6 E 20.084 200.000 140 67.084 to T 43.037 87.509 0.433 TEST 0 455.33 6.16 2F 20.084 287.509 0.0057 1.645 Vel= 4.90 G 4.304 250.00 Qa= 250.00 TEST 705.33 69.162 K Factor= 84.81 *NEW PATH 11 14.67 5.60 22.48 1.5 13.980 100 16.117 to 0.0 12 14.67 22.48 1.682 13.980 0.0227 0.318 Vel= 3.25 Computer Programs by Hydratec Inc. Revision: 50.5520.727 Final Calculations : Hazen-Williams SPRINKIT FIRE PROTECTION Page 6 Durham 0&M Date 8-11-21 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 12 14.67 5.60 22.70 1.5 11.080 100 16.435 to 0.0 13 14.67 45.18 1.682 11.080 0.0826 0.915 Vel = 6.52 13 14.67 5.60 23.33 1.5 E 3.533 5.570 100 17.350 to 3.533 0.0 14 14.67 68.51 1.682 9.103 0.1784 1.624 Vel= 9.89 14 14.67 0.0 1.5 T 7.065 0.580 100 18.974 to 7.066 0.251 15 14.09 68.51 1.682 7.646 0.1785 1.365 Vel= 9.89 15 14.09 0.0 2.5 8.000 100 20.590 to 0.009 7 14.07 68.51 2.635 8.000 0.0200 0.160 Vel= 4.03 0.0 7 68.51 20.759 K Factor= 15.04 *NEW PATH 17 14.63 5.60 22.93 1.5 8.080 100 16.764 to 0.0 18 14.63 22.93 1.682 8.080 0.0236 0.191 Vel= 3.31 18 14.63 5.60 23.06 1.5 8.080 100 16.955 to 0.0 19 14.63 45.99 1.682 8.080 0.0853 0.689 Vel= 6.64 19 14.63 5.60 23.52 1.5 5.990 100 17.644 to 0.0 20 14.63 69.51 1.682 5.990 0.1833 1.098 Vel = 10.04 20 14.63 5.60 24.24 1.5 E 3.533 0.760 100 -18.742 to 3.533 0.0 21 14.63 93.75 1.682 4.293 0.3189 1.369 Vel= 13.54 21 14.63 0.0 2 T 8.783 0.580 100 20.111 to 8.783 0.251 8 14.05 93.75 2.157 9.363 0.0949 0.889 Vel= 8.23 0.0 8 93.75 21.251 K Factor= 20.34 *NEW PATH 22 14.6 5.60 22.69 1.5 8.080 100 16.419 to 0.0 23 14.6 22.69 1.682 8.080 0.0230 0.186 Vel = 3.28 23 14.6 5.60 22.82 1.5 8.080 100 16.605 to 0.0 24 14.6 45.51 1.682 8.080 0.0838 0.677 Vel = 6.57 24 14.6 5.60 23.28 1.5 5.990 100 17.282 to 0.0 25 14.6 68.79 1.682 5.990 0.1798 1.077 Vel = 9.93 25 14.6 5.60 24.00 1.5 E 3.533 0.760 100 18.359 to 3.533 0.0 26 14.6 92.79 1.682 4.293 0.3128 1.343 Vel = 13.40 26 14.6 0.0 1.5 T 7.065 0.580 100 19.702 to 7.066 0.251 9 14.02 92.79 1.682 7.646 0.3127 2.391 Vel= 13.40 Computer Programs by Hydratec Inc. Revision: 50.5520.727 Final Calculations : Hazen-Williams SPRINKIT FIRE PROTECTION Page 7 Durham 0 & M Date 8-11-21 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe Notes Node2 Elev2 Fact Qt Act Egiv Len Total Pf/Ft Pf 0.0 9 92.79 22.344 K Factor= 19.63 *NEW PATH 27 14.58 5.60 23.54 1.5 7.500 100 17.676 to 0.0 28 14.58 23.54 1.682 7.500 0.0248 0.186 Vel= 3.40 28 14.58 5.60 23.67 1.5 7.500 100 17.862 to 0.0 29 14.58 47.21 1.682 7.500 0.0896 0.672 Vel= 6.82 29 14.58 5.60 24.11 1.5 7.500 100 18.534 to 0.0 30 14.58 71.32 1.682 7.500 0.1923 1.442 Vel= 10.30 30 14.58 5.60 25.03 1.5 E 3.533 0.760 100 19.976 to 3.533 0.0 31 14.58 96.35 1.682 4.293 0.3352 1.439 Vel= 13.91 31 14.58 0.0 1.5 T 7.065 0.580 100 21.415 to 7.066 0.256 10 13.99 96.35 1.682 7.646 0.3353 2.564 Vel= 13.91 0.0 10 96.35 24.235 K Factor= 19.57 Computer Programs by Hydratec Inc. Revision: 50.5520.727 8 I 7 I6 I 5 1 4 I 3 j 2 I 1 A Ell memo Aor Amon E"E 0 RELEASED ON ECN#0121 8/25/14 RM FACE OF OUTLET 1 RELEASED ON ECN#0144 1/21/15 RCL INTAKE FILTER 2 PER ECO#0065,CHANGED 4/14/16 DPH D -- DISCHARGE MANIFOLD. (1 ��.• AIR COMPRESSOR D I I • ASME RELIEF lJ l' I ��- VALVE(SEE TABLE) r.l—■— 4.50" PRESSURE-- CHECK VALVE SWITCH fo = ,, -41 6.00" I�OF SLOT 1/2"NPT OUTLETCONNECTION11 II I't,iiiiii, c �/ Cr OF OUTLET 4— S CH SETTINGS RELIEF NET ' MODEL VOLTA E DIM ��0�u�I�i; 14-1 OL32011 AC-LP MOTOR 115/2 8-30V/1 PH/60HZ PRESSURE 133 PSIG 10 40 PSIG PSIG 75 PSIG 114 25A" WEIGHT REBUILD" 1 KIT# 11 1 7 �_ 1 In OL12516AC 1/6 HP 115/208 230V/1 PH/60HZ� 27 TO 30 PSIG TO 44 PSIG 75 PSIG 14.25' I, OL39012AC-50 220-240V/1PH/50HZ 27 TO 30 PSIG 40 TO 44 PSIG 75 PSIG 14.25" B ii 30 Ibs. OLC-RK Ymm� I I B OL39012AC-LP-50 220-240V/1PH/50HZ 13 PSIG 18 PSIG 75 PSIG 14.25" OL25033AC 1/3 HP 115/208-230V/1PH/60HZ 27 TO 30 PSIG 40 TO 44 PSIG 75 PSIG 14.25" I. 4111 OL55033AC-LP 115/208-230V/1PHl60HZ 13 PSIG 18 PSIG 75 PSIG 14.25" _—' OL25033AC-HP 115/208-230V/1PW60HZ 80 PSIG ' 100 PSIG 125 PSIG 14.25" I OL75025AC-50 _ 75 PSIG 14.25" 31 LBS. 11.25" li ,�', 220-240V/1 PH/50HZ 27 TO 30 PSIG 40 TO 44 PSIG ii 10.25" OL75025AC-LP-50 220-240V/1PH/50HZ 13 PSIG 18 PSIG 75 PSIG 14.25" OL75025AC-HP-50 220-240V/1PH/50HZ 80 PSIG 100 PSIG 125 PSIG 14.25" _ �-�� *REBUILD KIT(OLC-RK)CONSISTS OF u REPLACEMENT CYLINDER,CUP AND INTAKE FILTER. INOTES: 1.COMPRESSOR APPEARANCE MAY VARY. A 2.DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. *GENERAL EIA L A 5.00" 3.ALL PIPING MUST BE INDEPENDENTLY SUPPORTED TO AN PaCrollat MOUNTING SLOTS — OF SLOT— AVOID ANY UNDO STRESS ON COMPRESSOR HEAD. w"Nw "+>F RE �4 �p�� ."R N GENERAL ARRANGEMENT .40"WIDE X 1.87"LONG ARETM•°E SOLE P O rtalJL S'WS R'"''� ,CYLINDER OIL LESS FIRE PROTECTION (4 PLACES) OINE*NWE SPEWED Iq CE THE CU° TSoYTHCRAKE �T GESSO/ COMPRESSOR.RISER MOUNT CRCNNOS ANN IN NWES W\HIT SE REPRODUCES OP IMAPPoWIE°.^. TM Rom"®ME. WPM CR IN PIM IN MT EGIIpYpf. 9¢ iwC1YY6 MEWLS MW8' N%THE wrITN 0IRE Cf SE pNRSute GAP OIL LESS COMPRESSORS CYCLONE\FULLASSEMBLIES\DRAWINGS\G-214210 REV 2 GENERAL ARRANGEMENT 1 CYLINDER RISER MOUNT.OWG wo "w°Ts"WI" M MY MR NNa* D °wc.m. G-214210 2 8 I 7 I 6 I 5 T 4 I 3 I 2 I 1 Worldwide orldwide www.tyco-fire.com t11IC1I Contacts Model DPV-1 Dry Pipe Valve External Resetting General Description - The TYCO Model DPV-1 Dry Pipe Valves are differential valves used to automatically control the flow of water , into dry pipe fire protection sprinkler - - - . systems upon operation of one or more S automatic sprinklers. The DPV-1 also provides for actuation of fire alarms upon system operation. The Model ' • a= DPV-1 features are as follows: - , - 1. - ' - • External reset. 1 • 250 psi(17,2 bar) pressure rating. . t:' • Unique offset single clapper design enabling a simple compact valve to minimize installation labor. • Ductile iron construction to ensure Available Sizes and End Connections a lightweight valve to minimize ship- plug cost. Nominal Valve Size • A variety of inlet and outlet End Connection 2-1/2 in. 3 in. 4 in. 6 in. (DN65) (DN80) (DN100) (DN150) connections. • Compact, Pre-Trimmed, and Semi- Flange x Flange N/A N/A Assembled, easy to operate valve Flange x Groove N/A N/A • • trim. Groove x Groove • ' • Simple reset procedure through the .=Available elimination of priming water. N/A=Not Available Dry pipe sprinkler systems are used in unheated warehouses, parking NOTICE Dry Pipe Valve garages, store windows, attic The Model DPV-1 Dry Pipe Valves The TYCO Model DPV-1 Dry Pipe spaces, loading docks, and other described herein must be installed Valves shall be installed in the verti- areas exposed to freezing tempera- and maintained in compliance with cal orientation only (supply at bottom tures, where water filled pipe cannot this document, as well as with the flowing upward)and are rated for use at be utilized. When set for service, the applicable standards of the National a maximum service pressure of 250 psi dry pipe sprinkler system is pressur- Fire Protection Association,in addition (17,2 bar). Valve and trim dimensions ized with air (or nitrogen). The loss of are shown in Figure 6. pressure through an operated auto- to the standards of any other toa do si- matic sprinkler in response to heat ties having jurisdiction.Failure to do so Flanged connections are available and from a fire permits the DPV-1 Dry may impair the performance of these drilled per ANSI,ISO,AS,and JIS spec- Pipe Valve to open and allow a flow of devices. ifications (Ref. Table A). The grooved water into the sprinkler system piping. The owner is responsible for main- outlet accordanceconnda withtions, as staappndard d groove are Table B establishes the minimum taming their fire protection system cut for steel pipe. T required system air pressure that and devices in proper operating con- specificationsfo forthgrooved oaThey are includes a safety factor to help prevent dition. Contact the installing contrac- suitable for use with grooved end pipe false operations that might occur due tor or product manufacturer with any f couplings that doare listeds or approved to water supply fluctuations. questions. for fire protection system service. Available combinations of inlet and outlet connections are described in Technical Data the Ordering Procedure section and in IMPORTANT the Available End Connection and Sizes Refer to Technical Data Sheet Approvals table on page 1. TFP2300 for warnings pertaining to FM Approved Listed Trim port connections of valves having regulatory and health information. NYC Approved flanges drilled to ANSI,AS,or JIS spec- Page 1 of 20 OCTOBER 2018 TFP1020 TFP1020 Page 2 of 20 NO.DESCRIPTION QTY. REF. 1 Valve Body 1 NR 2 Air and Water Seat 1 NR 3 Handhole Cover...1 NR 4 Handhole Cover Gasket 1 (b) 4110 11 5 1/2-13 UNC x 1"Hex Head Cap Screw: ' �' r 2-1/2&3 Inch 12 Valves 5 CH 6 4 Inch Valve 6 CH ")j' Q __13 6 Clapper 1 (a) ��� 7 Clapper Facing....1 (a)or(b) .- 7 CLAPPER RESET 8 Clapper Facing �' 14 PLUNGER Retaining Plate....1 (a) ASSEMBLY Q/ PARTS 9 2-1/2 and 3 Inch Valves: 8 • - 15,18 11 3 Long • #10-32 -32 Shoulder 9 Screw 5 (a) -18 4 Inch Valve: 1/4-20 UNC x 1/2" Socket Head Cap 17 Screw 7 (a) 10 Clapper Hinge — Pin 1 (a) 11 Reset Knob 1 (c)or(d) 13 Reset Spring 1 (c) n%, # .0, 13 Reset Bushing ....1 (c) 14 Reset Bushing #, 0-Ring. 1 (b),(c)or(e) 15 Reset Plunger a; 0-RIng 1 (b)or(c) 16 Reset Plunger 1 (c) _ 17 Reset Latch t w Subassembly 1 (c) //� \ jii 18 Dow Corning FS3452 y Flourosilicone \\ 1 Grease,1.5 g 1 (b)or(c) "� 4 NR: Not Replaceable 2 3 CH:Common Hardware ki d.°i,L.,L7',-------'-' $ ,�® REPLACEMENT PARTS F �� NO.DESCRIPTION P/N / --..„6 �0 (a) Clapper Assembly ' �- Includes Items 6-10: 0 0 2-1/2&3 Inch Valves.. 92-310-2-203 4 Inch Valve 92-310-2-403 �l \®� (b) Repair Parts Kit 10 Includes Items ,_ 5 4,7,14, 15,&18: 2-1/2&3 Inch Valves.. 92-310-1-204 4 Inch Valve 92-310-1-404 (c) Reset Plunger Parts Kit Includes Items 11-18.. 92-310-1-405 (d) Reset Knob, Item 11... 92-310-1-406 (e) Reset Plunger 0-Ring,Item 15 92-310-1-407 FIGURE 1-PART 1 OF 2 MODEL DPV-1 DRY PIPE VALVE 2-1/2,3,AND 4 INCH(DN65,DN80, DN100)ASSEMBLIES TFP1O2O Page 3 of 20 NO. DESCRIPTION QTY. REP.PART NO. DESCRIPTION QTY. REP.PART NO.DESCRIPTION QTY. REP.PART 1 Valve Body 1 NR 5 Socket Head Cap 8 Hex Head Cap Screw 2 Air and Water Screw 5/8-11 UNC x 1"...6 CH Seat 1 NR 3/8-16 UNC x 1"...8 NR 9 Clapper 1 (a) 3 Water Seal 6 Handhole Cover.. .1 NR 10 Clapper Facing....1 (a)or(b) 0-Ring 1 NR 7 Handhole Cover 11 Clapper Facing 4 Air Seal 0-Ring... .1 NR Gasket 1 (b) Retaining Plate....1 (a) 12 Socket Head Cap Screw 1/4-20 UNC x 1/2':.9 (a) 14 13 Clapper Hinge Pin..1 (a) 14 Reset Knob 1 (c)or(d) 15 Reset Spring 1 (c) i� i / 9 F15 16 Reset Bushing . .. .1 (c) / '' / 17 Reset Bushing £' Q 16 O-Ring 1 (b),(c)or(e) ��' 10 /I� 18 Reset Plunger \ / CLAPPER RESET 0-Ring 1 (b)or(c) tr„ J . 11 ASSEMBLY 0�17 PLUNGER PARTS 19 Reset Plunger 1 (c) 20 Reset Latch f/// Subassembly 1 (c) ��/ 18,21 1P .,,,—el Flourosilicone Dow Corning FS3452 o � Flourosilicone 19 Grease, 1.5 g 1 (b)or(c) 0 0 NR:Not Replaceable ..3,4 20 CH:Common Hardware O --------,yF`' O REPLACEMENT PARTS .• 0 4' NO. DESCRIPTION P/N 4 (a) Clapper Assembly / % Includes Items 9-13. .. 92-310-2-603 (b) Repair Parts Kit 2 Includes Items 7,10, 17,18,21 92-310-1-604 I �11l (c) Reset Plunger Parts Kit , //— �/ %' 0 Includes Items 14-21 .. 92-310-1-405 // / (\ (d) Reset Knob,Item 14... 92-310-1-406 a '^— \ + � (e) Reset Plunger I I &.• n O-Ring,Item 18 92-310-1-407 it • 4 1 7 6 5` 0P., ,,, � r ® 0 13 / ' 0 / 0 _'�- �' lIl 1*--_----- 8 � Q - 0 FIGURE 1 -PART 2 OF 2 MODEL DPV-1 DRY PIPE VALVE 6 INCH(DN150)ASSEMBLY TFP1 020 Page 4 of 20 Flange Drilling Specification Nominal Dimensions in Inches and(mm) Dim.A Nominal Bolt Circle Valve ANSI B16.11 ISO 7005-2 JIS B 2210 AS 2129 Diameter Size (Class 125) (PN16)2 (10K) (Table E) ©-0 Dim. Dim. Qty. Dim. Dim. Qty. Dim. Dim. Qty. Dim. Dim. Qty. ((' ,) ' Dim.B A B N A B N A B N A B N ' BoltHole 4 in. 7.50 0.75 7.09 0.75 6.89 0.59 7.00 0.71 Diameter (DN100) (190,5) (19,0) (180,0) (19,0) 8 (175,0) (15,0) 8 (1780) (18,0) 8 -__- 6 in. 9.50 0.86 9.45 0.91 9.45 0.75 9.25 0.87 Qty.N (DN150) (241,3) (22,2) 8 (240,0) (23,0) 8 (240,0) (19,0) 8 (235,0) (22,0) 8 Number of Bolt Holes 1. Drilling same as ANSI B16.5(Class 150)and ANSI B16.42(Class 150). 2. Drilling same as BS 4504 Section 3.2(PN16)and DIN 2532(PN16). TABLE A • SELECTION OF FLANGE DRILLING SPECIFICATIONS ifications are NPT threaded per ANSI Pre-trimmed valve assemblies also 4 in.(DN100)FxF 77 lb(36 kg) Standard B1.20.1. Trim port connec- include the following equipment: 6 in.(DN150)GxG 95 lb(44 kg) tions of valves having flanges drilled • Model BFV-300 butterfly valve to ISO are available either threaded 6 in.(DN150)FxG 108 lb(50 kg) per ISO 7-1 or NPT threaded per ANSI • Figure 577 grooved coupling 6 in.(DN150)FxF 121 lb(56 kg) Standard B1.20.1. Valves with NPT • PS10-2 waterflow alarm switch threaded ports will readily accept the Air Supply trim arrangements shown in Parts 2 • PS40-2 low air pressure alarm switch Table B shows the system air pres- and 3 of Figures 3,4,and 5. sure requirements as a function of the Order the above equipment sepa- water supply pressure.The air(or nitro- Model DPV-1 Valve assemblies are rately when ordering trim packages gen) pressure in the sprinkler system shown in Figure 1.The Body and Hand- separately. is recommended to be automatically hole Cover are ductile iron.The Hand- Note: When the system pressure is maintained by using one of the follow- hole Cover Gasket is neoprene, and greater than 175 psi(12,1 bar),provision ing pressure maintenance devices, as the Clapper Facing is EPDM. The Air/ shall be made to replace the standard appropriate: Water Seat Ring is brass, the Clapper order 300 psi(20,7 bar)Water Pressure . Model AMD-1 Air Maintenance is bronze or aluminum bronze,and both gauge with a separately ordered 600 the Clapper Retaining Plate and Latch Device(pressure reducing type) psi(41,4 bar) Water Pressure Gauge. are bronze.The Hinge Pin is aluminum • Model AMD-2 Air Maintenance bronze,and the fasteners for the Hand- Weights Device(compressor control type) hole Cover are carbon steel. The following are the nominal weights Valve Trim for Pre-Trimmed Valve Assemblies, • Model AMD-3 Nitrogen Maintenance Installation dimensions are provided Semi-Assembled Trim, and DPV-1 Device(high pressure reducing type) Valves without trim. The Pressure Relief Valve provided with in Figure 6, and Valve Trim and Pre- Trimmed Valve Assemblies are shown Pre-Trimmed DPV-1 Valve the valve trim is factory set to relieve in Figures 3,4,and 5. Assemblies: at a pressure of approximately 45 psi (3,1 bar). If the normal system air pres- The valve trim,ordered separately or as 2-1/2 in.(DN65)GxG 87 lb(40 kg) sure is less than or exceeds 40 psi(2,8 a pre-trimmed valve assembly, forms 3 in.(DN80)GxG 90 lb(42 kg) bar), then the pressure Relief Valve a part of the laboratory listings and must be reset to relieve at a pressure approvals of the DPV-1 Valve and is 4 in.(DN100)GxG 121 lb(56 kg) that is in accordance with the authority necessary for the proper operation of 4 in.(DN100)FxG 135 lb(64 kg) having jurisdiction. the DPV-1 Valve. Trim packages or re trimmed valve 4 in.(DN100)FxF 145 lb(69 kg) Quick Opening Device P 9 P The Model DPV-1 Dry Pipe Valve may assemblies include the following 6 in.(DN150)GxG 175 lb(81 kg) optionally be equipped with an elec- equipment: 6 in.(DN150)FxG 195 lb(90 kg) tronic or mechanical dry pipe valve • Water Supply Pressure Gauge 6 in.(DN150)FxF 208 lb(96 kg) accelerator. Select the VIZOR Elec- • System Air Pressure Gauge tronic Dry Pipe Valve Accelerator Standard Galvanized (4 and 6 in. sizes only) described in • Air Supply Connections Semi-Assembled DPV-1 Trim: Technical Data Sheet TFP1105 or the Model ACC-1 Mechanical Dry Pipe • Main Drain Valve 2-1/2 in.(DN65) 23 lb(11 kg) Valve Accelerator(2-1/2 through 6 in. • Low Body Drain Valve 3 in.(DN80) 23 lb(11 kg) sizes) described in Technical Data • Alarm Test Valve 4 in.(DN100) 30 lb(14 kg) Sheet TFP1112. The VIZOR or the ACC-1 is used to • Automatic Drain Valve 6 in.(DN150) 30 lb(14 kg) reduce the time to valve actuation fol- • Drip Funnel DPV-1 Valve(Without Trim): lowing the operation of one or more • Connections For Optional Quick 2-i/2 in.(DN65)GxG 37 lb(17 kg) automatic sprinklers. In some cases the use of a quick opening device Opening Device(Accelerator) 3 in.(DN80)GxG 38 lb(18 kg) such as the VIZOR or the ACC-1 may 4 in.(DN100)GxG 57 lb(26 kg) be required to meet the requirements of the National Fire Protection Association 4 in.(DN100)FxG 67 lb(31 kg) to meet water delivery times. TFP1020 Page 5 of 20 Maximum System Air FLOW RATE IN LITRES PER MINUTE(LPM) Water Supply Pressure (1 GPM=3.785 LPM) Pressure Range 500 700 1000 2000 3000 5000 10000 psi psi .g0 11IIIIUIIl 1IIIII) (I III 1 11/// jI. II 'lull[ ( IJ II 0,60 20 10 a 7.0 0,50 60 15-23 I - 0,40 80 20-28 z 5.0 f�T 0,30 100 25-33 4.0 �O .... t ....- 145 35-43 3.0 O=' 1 -0,20 a 165 40-48 co ¢ ?U� - - z 185 45-53 a 2.0 r� o - OQ 205 50-58 0 °dr 1 0,10 CC m 0 to 225 55-63 _ `0 � =0,08 250 60-68 O 1.0 `c2 7 S = - cc o d -2'-r-2--r— — 0,06 =o TABLE B z '2v v OS c 0,05 w II SYSTEM AIR PRESSURE p 0 7 wl r -0,04 Cl-s REQUIREMENTS o 0.5 — N -- ¢ 0.4 - - -—_0,03 z p 0 Operation 0 3 0 02 z The TYCO Model DPV-1 Dry Pipe Valve ¢ -_LIJ _ _ is a differential type valve that utilizes a a 0.2 _. -- substantially lower system(air or nitro- z • - gen) pressure than the supply (water) 2 - '0,01 pressure, to maintain the set position 0 = _ shown in Figure 2A. The differential z 0.1 — nature of the DPV-1 is based on the 100 200 300 500 700 1000 2000 3000 area difference between the air seat FLOW RATE IN GALLONS PER MINUTE(GPM) and the water seat in combination with The approximate friction losses,based on the Hazen and Williams formula and expressed In equivalent length of the ratio of the radial difference from Schedule 40 pipe with C=100 and flowing at typical flow rates,are as follows: the Hinge Pin to the center of the Water 2-1/2 in.valve at 250 GPM flow=2.2 ft 4 in.valve at600 GPM flow=8.9ft Seat and the Hinge Pin to the center of 3In.valveat350GPMflow=4.9ft 6 in.valve at 1500 GPM flow=22.0 ft the Air Seat.The difference is such that GRAPH A 1 psi (0,07 bar) of system air pressure MODEL DPV-1 DRY PIPE VALVES can hold approximately 5.5 psi (0,38 NOMINAL PRESSURE LOSS VS.FLOW bar)of water supply pressure. Table B establishes the minimum sure of 100 psi (6,9 bar). It is for this After a valve actuation and upon sub- required system air pressure that reason that the'plunger of the Auto- sequent closing of a system main includes a safety factor to help prevent matic Drain Valve must be depressed control valve to stop water flow, the false operations that occur due to water during several of the resetting steps, Clapper Assembly will latch open as supply fluctuations. as well as during inspections, making shown in Figure 3D. Latching open of certain that the Automatic Drain Valve the DPV-1 will permit complete drain- The Intermediate Chamber of the is open. ing of the system (including any loose DPV-1 is formed by the area between When one or more automatic sprin- scale)through the main drain port. the Air Seat and Water Seat as shown in klers operate in response to a fire, During the valve resetting procedure Figure 2The Intermediate Chamber air pressure within the system piping and after the system is completely normallyly remains at atmospheric pres- is relieved through the open sprin- drained,the external reset knob can be sure through the Alarm Port connection klers. When the air pressure is suf- easily depressed to externally unlatch Automaticand the valve triman Valveto the n(Fig. lly3, open ficiently reduced, the water pressure the Clapper Assembly, as shown Drain (Fig. 3, 4, or 5). Having the Intermediate Chamber, overcomes the differential holding in Figure 2E. As such, the Clapper Figure 2B,open to atmosphere is criti- the Clapper Assembly closed and the Assembly is returned to its normal set cal to the DPV-1 Valve remaining set, Clapper Assembly swings clear of the position to facilitate setting of the dry otherwise the full resulting pressure of water seat, as shown in Figure 2C, pipe sprinkler system,without having to the system air pressure on top of the This action permits water flow into the remove the Handhole Cover. Clapper Assembly cannot be realized. system piping and subsequently to be discharged from any open sprinklers. For example, and assuming a water Also,with the Clapper Assembly open, supply pressure of 100 psi(6,9 bar), if the intermediate chamber is pressur- the system air pressure is 25 psi (1,7 ized and water flows through the alarm bar) and there was 15 psi (1,0 bar) port(Ref. Figure 2B) at the rear of the pressure trapped in the Intermediate DPV-1 Valve to actuate system water Chamber,the resulting pressure across flow alarms. The flow from the alarm the top of the Clapper would only be 10 port is also sufficient to close the oth- psi (0,7 bar). This pressure would be erwise normally open Automatic Drain insufficient to hold the Clapper Assem- Valve in the valve trim. bly closed against a water supply ores- . TFP1O2O Page 6 of 20 Installation be equipped with a Dry Pipe Valve however, it must be reset to relieve Accelerator, refer to the Technical at a pressure which is in accordance General Instructions Data Sheet TFP1105 for the VIZOR with the requirements of the author- Proper operation of the Model DPV-1 Electronic Dry Pipe Valve Accel- ity having jurisdiction. Dry Pipe Valve depends upon its trim erator or TFP1112 for the Model To reset the Pressure Relief Valve, being installed in accordance with the ACC-1 Mechanical Dry Pipe Valve first loosen the jam nut and then instructions given in this Technical Data Accelerator. adjust the cap accordingly— Sheet. Failure to follow the appropriate • Care must be taken to make sure that clockwise for a higher pressure trim diagram may prevent the DPV-1 check valves,strainers,globe valves, setting or counter-clockwise for a Valve from functioning properly, as etc.are installed with the flow arrows lower pressure setting.After veri- well as void listings,approvals,and the in the proper direction. fying the desired pressure setting, manufacturer warranties. tighten the jam nut. • Drain tubing to the drip funnel must • Installation of an Air Maintenance Failure to latch open the Clapper be installed with smooth bends that Device, as described in the Techni- Assembly prior to a system hydro- will not restrict flow. cal Data Section, is recommended. static test may result in damage to the • The main drain and drip funnel drain Clapper Assembly. may be interconnected provided a • An Inspector's Test Connection as The DPV-1 Valve must be installed in a check valve is located at least 12 in. required By NFPA 13 must be pro- readily visible and accessible location. (300 mm)below the drip funnel.The vided on the system piping at the Low Body Drain Valve(Figure 3,4,or most remote location from the Model The DPV-1 Valve and associated trim 5) may be piped so as to discharge DPV-1 Valve. must be maintained at a minimum tern- into the DripFunnel or to a separate pasture of 40°F(4 C). P Conduit and electrical connections drain. are to be made in accordance with Heat tracing of the DPV-1 Valve or its the requirements of the author- associated trim is not ermitted. Heat • Suitable provision must be made tracing can result in the formation of for disposal of drain water. Drainage Nation itl inElectr c Coden and/or the hardened mineral deposits that are water must be directed such that it capable of preventing proper operation. will not cause accidental damage to • Before a system hydrostatic test is property or danger to persons. performed in accordance with NFPA The Model DPV-1 Dry Pipe Valve is to . Unused pressure alarm switch and/ 13 system acceptance test require- be installed in accordance with the fol- or water motor alarm connections ments, the Clapper Assembly is to lowing criteria: must be plugged. be manually latched open (Ref. Fig- • All nipples,fittings,and devices must ure 2D); the Automatic Drain Valve be clean and free of scale and burrs • The Pressure Relief Valve provided (Figure 3,4,or 5)is to be temporarily before installation. Use pipe thread with the Valve Trim is factory set to replaced with a 1/2 in.NPT plug,the sealant sparingly on male pipe relieve at a pressure of approximately 3/32 in.Vent Fitting(Item 13, Figure threads only. 45 psi (3,1 bar), which can typically 3; Item 15, Figure 4; or Item 15, Fig- be used for a maximum normal sys- ure 5) is to be temporarily replaced • The DPV-1 Valve must be trimmed tern air pressure of 40 psi (2,8 bar). with a 1/4 in. NPT plug, and the in accordance with Figures 3, 4, or The Pressure Relief Valve may be Handhole Cover Bolts are to be tight- 5, as applicable. If the DPV-1 is to reset to a lower or higher pressure; ened using a cross-draw sequence. TFP1020 Page 7 of 20 Valve Setting Step 5.As necessary,replace all sprin- to the Care and Maintenance section klers that have operated.Replacement under Automatic Drain Valve Inspection Procedure sprinklers must be of the same type to determine/correct the cause of the and temperature rating as those which leakage problem. Steps 1 through 11 are to be performed have operated. Step 10. Partially open the Main when initially setting the Model DPV-1 Control Valve. Slowly close the Main Dry Pipe Valve;after an operational test NOTICE Drain Valve as soon as water dis- of the fire protection system; or, after In order to prevent the possibility of charges from the drain connection. system operation due to a fire. a subsequent operation of an over- Depress the plunger on the Automatic NOTES:If the DPV-1 is equipped with heated solder type sprinkler,any solder Drain Valve to make sure that it is open a Dry Pipe Valve Accelerator, refer to type sprinklers which were possibly and that there is no water discharging. its resetting instructions before reset- exposed to a temperature greater than The absence of water discharging from must bet bi d t amen maximum rated ting the DPV-1.Refer to TFP1105 for the theirthe Automatic Drain Valve is an indica- VIZOR or TFP1112 for the ACC-1. replaced. tion of a properly set water seat within Based on the instructions provided, Step 6.Push down on the Reset Knob the DPV-1 Valve. If water is discharg- reset the Accelerator at the appropriate (Figure 2E)to allow the Clapper Assem- ing,refer to the Care and Maintenance time during the resetting of the DPV-1. bly to re-seat. section under the Automatic Drain Step 7. Pressurize the system with air Valve Inspection to determine/correct Unless otherwise noted,refer to Figure (or nitrogen) to 10 psi (0,7 bar), and the cause of the leakage problem. 3, 4, or 5 to identify functional trim components. then individually open all auxiliary drain If there are no leaks,the DPV-1 Valve is valves in the system piping to drain ready to be placed in service and the Step 1. Close the Main Control Valve, any remaining water in trapped sec- Main Control Valve must then be fully and close the Air Supply Control Valve. tions. Close each drain valve as soon opened. If the DPV-1 is equipped with a Dry as water ceases to discharge. Note: After setting a fire protection Pipe Valve Accelerator,remove the Dry Also partially open the Low Body Drain system, notify the proper authorities Pipe Valve Accelerator from service in accordance with its Technical Data Valve to assure that the riser is com- and advise those responsible for moni- Sheet(Refer to TFP1105 for the VIZOR pletely drained. Close the Low Body toring proprietary and/or central station or TFP1112 for the ACC-1). Drain Valve as soon as water ceases alarms. to discharge. Step 11. Once a week after a valve is Step 2.Opthe Main Drain Valve and Step 8. Refer to Table B and then reset following an operational test or all auxiliaryary drains in the system.Close restore the system to the normal system operation,the Low Body Drain the auxiliary drain valves after water ceases to discharge. Leave the Main system air pressure as necessary to Valve (and any low point drain valves) Drain Valve open. hold the DPV-1 Valve closed. should be partially opened (and then 9.Step Depress the plunger on the subsequently closed) to relieve drain- Step 3. Depress the plunger of theback water. Continue this procedure Automatic Drain Valve to verify that it is Automatic Drain Valve to make sure until drain-back water is no longer open and that the DPV-1 Valve is corn- it is open and that there is no air present. pletely drained. discharging. Step 4. Open the Optional Alarm The absence of air discharging from Control Valve, as applicable, if it was the Automatic Drain Valve is an indica- closed to silence local alarms. tion of a properly set air seat within the DPV-1 Valve. If air is discharging, refer TFP1020 Page 8 of 20 AIR PRESSURE WATERFLOW TO SYSTEM TO SYSTEM Alt I CLAPPER CLAPPER 1"NPT ) i ASSEMBLY ASSEMBLY AIR SUPPLY INSET FULLY OPEN PORT POSITION 1 � i CLAPPER LATCH Orr ,4 � 1/2"NPT �� PIVOTS TO ALLOW ':�I$ WATER .4 CLAPPER ASSEMBLY =t'� SUPPLY 7/////�//////y///y/Az_.., TO FULLY OPEN PRESSURE .;d !,--,9,�' i 3/4"NPT ALARM �'.�- &ALARM 14, i'1 _ PORT OPEN TO NW TEST PORT - �V ATMOSPHERE -it rii 02 01 `d 03 IN ALARM PORT 'S WATERFLOW CLAPPER rTO ALARM ASSEMBLY FROM FROM WATER SUPPLY AIR WATER SUPPLY SEAT FIGURE 2A D///y/� FIGURE 2C ' SET POSITION SEAR ���� ^^ 03 ALARM OPERATED POSITION _;.?�, PORT DRAIN FROM DRAIN FROM SYSTEM SYSTEM VALVE INTERMEDIATE COMPLETE IWATERWAY CHAMBER PUSH HERE FIGURE 28 TO RESET SET POSITION VALVE INTERMEDIATE CHAMBER RESET CLAPPER KNOB ASSEMBLY / '*1/4\ a i i \ '--- LATCHED = axe OPEN RESET ���' �c� ss=� ASSEMBLY CLAPPER `04, � LATCH �� eii µ�„�� PIVOTS TO '� CLAPPER UNLATCH / //y///////////�- 1 LATCH CLAPPER r " €;t 2 ASSEMBLY �� lily 04 Ilk � MAIN DRAIN PORT: ���i` '" 3/4"NPT 05 1-1/4" NPT'(2-1/2INCH CLAPPER LOW BODY 1� ���� &3 INCH VALVES) �� 11�� ASSEMBLY DRAIN 2" NPT(4 INCH VALVE) RESEATED PORT WATER SUPPLY DN40 FOR VALVES WITH WATER SUPPLY SHUT OFF ISO THREADED PORTS SHUT OFF FIGURE 2D FIGURE 2E DRAIN POSITION RESET POSITION FIGURE 2- PART 1 OF 2 MODEL DPV-1 DRY PIPE VALVES 2-1/2,3,AND 4 INCH(DN65, DN80,AND DN100) SET AND OPEN POSITIONS TFP1O2O Page 9 of 20 AIR PRESSURE WATERFLOW TO SYSTEM TO SYSTEM I CLAPPER ASSEMBLY vr- FULLY OPEN FW 1"NPT 74. i CLAPPER LATCH 76 it AIRPORT SUPPLY = PIVOTS TO ALLOW `� CLAPPER ASSEMBLY ��\ 01 _ TO FULLY OPEN ��/ 3/4" NPT ALARM �'_�� �g •"- 03 PORT OPEN TO -v ♦ CLAPPER ATMOSPHERE \` ASSEMBLY �-I ��l"` POSITION SET L.2, ,t_ //,� u. ,--- 1/2" NPT • m- 'v WATER SUPPLY . P �� , .,s 02 Millilil! _Isii IllilIlir TEST PORT ALARM PORT WATERFLOW CLAPPER , ,t „ TO ALARMc ASSEMBLY AIR FROM SEAT FROM WATER SUPPLY WATER SUPPLY _�...N2 FIGURE 2C FIGURE 2A f�j I ALARM SET POSITION WATER rA•iiiiiiie�2i" � PORT OPERATED POSITION ,.� III I I / 03 DRAIN FROM DRAIN FROM SYSTEM SYSTEM INTERMEDIATE,' VALVE COMPLETE ICHAMBER FIGURE 2B WATERWAY j PUSH HERE TO RESET pal SET POSITION _ VALVE INTERMEDIATE CLAPPER CHAMBER e 4 RESET ASSEMBLY LATCHED AKNOB OPEN S RESET s� g ASSEMBLY 04 3W NPT �� ��.��� CLAPPER LOW BODY . ��� LATCH i DRAIN /y��IFC �` PIVOTS TO PORT 00 �� UNLATCH /� � 1 04 ��i/ .. CLAPPER /!�////////////////// /////I%/'.ry ga‘9.-11g1r.7w%.s,Ar, oSm,NewOr P- ASSEMBLY srril ��a�\11..m0.CLAPPER FilliP?MN DRAIN Ilr6 ,2 664i5' CLAPPER IIIIII �^^ ASSEMBLY 05 ffi RESEATED WATER SUPPLY WATER SUPPLY SHUT OFF SHUT OFF FIGURE 2D FIGURE 2E DRAIN POSITION RESET POSITION FIGURE 2-PART 2 OF 2 MODEL DPV-1 DRY PIPE VALVES 6 INCH(DN15O) SET AND OPEN POSITIONS TFP1020 Page 10 of 20 NOTES: 1. SEE FIGURE 3 PART 3 FOR TRIM ARRANGEMENT WITH BILL OF MATERIALS LOW AIR AND COMPONENT PART NUMBERS. PRESSURE 2. TRIM SHOWN FULLY ASSEMBLED;COMPONENTS SUCH AS GAUGES AND ALARM SWITCHES MAY REQUIRE ASSEMBLY IN TRIM AT INSTALLATION. SWITCH SYSTEM AIR SUPPLY 1 INCH NPT SYSTEM reCONTROL VALVE CONNECTION AIR SUPPLY 4, (NORMALLY FOR LOCAL PRESSURE kw,. 10(, OPEN) SPRINKLER GAUGE rig'' 2-1/2 INCH(DN65) \ WATERFLOW 1/2 INCH NPT or 3 INCH PV-1 ,(�� ; PRESSURE CONNECTION MODEL DPV-1 f I+ ALARM FOR SYSTEM DRY PIPE VALVE l��(n�4 SWITCH A IL- AIR SUPPLY (GxG ONLY) ;y',. .16 '`A 'rr / GROOVED MAIN -�rl,-�I COUPLING ALARM w. :"'_,,,, 3 (TEST NORMALLY y-----1/ DRAIN VALVE �� � (NORMALLY (NORMALLY 11 1/2 INCH NPT CLOSED) SYSTEM CLOSED) CONNECTION 3/4 INCH NPT \ SYSTEM �I FOR OPTIONAL WATER CONNECTION SHUT-OFF 1-1/4 INCH NPT ,........-- ACCELERATOR SUPPLYPRESSURE TO DRAIN VALVE CONNECTION GAUGE LOW BODY (NORMALLY TO DRAIN AUTOMATIC DRAIN VALVE OPEN) DRAIN VALVE (NORMALLY 1-1/4 INCH NPT CLOSED) CONNECTION DRIP TO DRAIN FUNNEL FIGURE 3-PART 1 OF 3 2-1/2 AND 3 INCH(DN65 AND DN80)MODEL DPV-1 DRY PIPE VALVE PRE-TRIMMED ASSEMBLY AIR SUPPLY 1/2 INCH NPT 1/2 INCH NPT NOTES: CONTROL VALVE CONNECTION CONNECTION 1. INSTALL TRIM ASSEMBLIES IN (NORMALLY OPEN) FOR OPTIONAL FOR OPTIONAL ALPHABETICAL ORDER. ACCELERATOR AIR PRESSURE AUTOMATIC SWITCH 2. SEE FIGURE 2 FOR VALVE PORT 1/2 INCH NPT DRAIN VALVE IDENTIFICATION. CONNECTION FOR SYSTEM tTre / a 3. ROUTE 1/4"TUBING TO DRIP AIR SUPPLY H\ * `14 r�/Ie U SYSTEM FUNNEL. ��aer-----,•,r` Or 7 AIR SUPPLY MAIN 1/2 INCH NPT 110- l D - PRESSURE DRAIN VALVE „'4: GAUGE (NORMALLY CONNECTION (a` A FOR WATERFLOW \ '1 E CLOSED) PRESSURE ALARM t�, v I,.' SWITCH �� ,".k �Zjj �' II 3 „ 05 \-� 1-1/4 INCH NPT DRIP 0< 4 1p CONNECTION FUNNEL I 01 TO DRAIN --�\ t�� �y' 1-1/4 INCH NPT �� le �1(,��� CONNECTION 'swat, 2-1/2 INCH(DN65) TO DRAIN 1 INCH NPT p2 or 3 INCH(DNBO) CONNECTION y C d MODEL DPV-1 FOR LOCAL De p DRY PIPE VALVE SPRINKLER 'ilk loge (GxG ONLY) IyN r`� F / t:41? LOW BODY ALARM �• �i B l �� DRAIN VALVE TEST VALVE SYSTEM �? (NORMALLY (NORMALLY CLOSED) WATER SUPPLY 3/4 INCH NPT CLOSED) PRESSURE CONNECTION GAUGE TO DRAIN FIGURE 3-PART 2 OF 3 2-1/2 AND 3 INCH(DN65 AND DN80)MODEL DPV-1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF SEMI-ASSEMBLED TRIM TFP1020 Page 11 of 20 NO. DESCRIPTION QTY P/N NO. DESCRIPTION QTY P/N NO. DESCRIPTION QTY P/N 1 250 psi/1750 kPa 13 3/32"Vent 28 1"x 1"x 1/2" Air Pressure Fitting 1 92-032-1-002 Reducing Tee 1 CH Gauge 1 92-343-1-012 14 1/4"Tube, 29 Not Used 2 300 psi/2000 kPa 18"Long 1 CH PIPE NIPPLES: Water Pressure 15 1/4" Plug 2 CH 30 1/4"x 3" 2 CH Gauge 1 92-343-1-005 16 1/2" Plug 2 CH 31 1/2"x Close 4 CH 3 1/4"Gauge Test 17 1"Plug 1 CH 32 1/2"x 1-1/2" 8 CH Valve 2 46-005-1-002 18 1/2" Union 1 CH 33 1/2"x2" 1 CH 4 Model AD-1 19 1/2"x 1/4" Reducing 34 1/2"x 4-1/2" 1 CH Automatic Bushing 1 CH 35 1/2"x 6" 1 CH Drain Valve 1 52-793-2-004 20 1/2"90°Elbow. .. .3 CH 36 3/4"x Close 1 CH 5 1/4"Pressure 21 3/4'90°Elbow. .. .1 CH 37 3/4"x 1-1/2" 1 CH Relief Valve 1 92-343-1-020 22 1-1/4'90°Elbow...1 CH 38 3/4"x 2-1/2" 1 CH 6 1/2"Ball Valve ....2 46-050-1-004 23 1/2"Cross 2 CH 39 1"x Close 1 CH 7 3/4"Angle Valve...1 46-048-1-005 24 1/2"x 1/2"x 1/4" 40 1-1/4"x Close ....1 CH 8 1-1/4"Angle Valve .1 46-048-1-007 Reducing Tee 1 CH 41 1-1/4"x 4" 1 CH I 9 1/2"Swing 25 1/2"Tee 1 CH COMPONENTS INCLUDED ONLY IN Check Valve 2 46-049-1-004 26 1/2"x 1/4"x 1/2' PRE-TRIMMED VALVE ASSEMBLIES: 10 Drip Funnel Reducing Tee 2 CH Connector 1 92-211-1-005 27 1/2"x 1/2"x 3/4' 42 Model BFV-300 11 Drip Funnel Reducing Tee 1 CH Butterfly Valve, Bracket 1 92-211-1-003 2-1/2"(DN65) 1 59300G025WS 12 Drip Funnel 1 92-343-1-007 3"(DN80) 1 59300G030WS 45 43 Figure 577 Coupling, 2-1/2"(DN65) 1 57725ACP ,C ,..„.. • 16 3" (DN80) 1 57730ACP 44 Waterflow Pressure 20 Alarm Switch, tXC 1 Model PS10-2 1 25710 9 �` 11�� yFi< c5 19 45 Low Air Pressure 32 32 It% 30 Alarm Switch, 6� \p\\ 23 C 4,,> Model PS40-2 1 25730 5 a 32 - :: ` 32 i �.. 24 i\�\\ 32 � 4-�".Yi';, % •se n;, 15 �"." 20 17 / 34 �1� � 39 3 I 28 Ate 'A 33 2-1/2 INCH(DN65) 44 CY, or 3 INCH((DN65 %\ 9 16 4 MODEL DPV-1 25 31 27 tv, $01 1'," DRY PIPE VALVE Al (GxG ONLY) 31 LOCATION 1.1.1 Of 23 FOR OPTIONAL ,\VN\ 36 ) ��i 41 111\ ) 8 1: ELECTRICALLY �I 10 ((fQ0 �`�% -',."0 SUPERVISED 32 r' P2 r1fr- N.O.ALARM 20 �� 03 ' 0y 40 It- N.O. 31 CONTROL 11 (�a Fo ��ry� VALVE / 26 � R 01i' r 13 0 12 37 04 `►� -�� NOTES: (GREEN ((.�c ��j�l ,� 43 1. SEE FIGURE 2 FOR VALVE TINT) ri14 21 r ! ! PORT IDENTIFICATION. L � �— ��� 38 E! ��rt 0� '0�' 42 2. ROUTE 1/4"TUBING,ITEM 14, 31 g7i ,' t4 7 %\ TO DRIP FUNNEL,ITEM 12. ipo 6 # ( 0, f� 4\\ a\. ` 3. ALL FITTINGS AND NIPPLES II 32 q, 35 4' � ARE GALVANIZED. 26 2 % fjl 4. CH:COMMON HARDWARE 30 � t 5. ITEMS 42-45 INCLUDED 3 ' A, ONLY IN PRE-TRIMMED VALVE ASSEMBLIES AS APPLICABLE;OTHERWISE SEPARATELY ORDERED. FIGURE 3-PART 3OF3 2-1/2 AND 3 INCH(DN65 AND DN8O)MODEL DPV-1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF VALVE TRIM TFP1020 Page 12 of 20 1. SEE FIGURE 4 PART 3 FOR TRIM ARRANGEMENT WITH BILL OF MATERIALS LOW AIR AND COMPONENT PART NUMBERS. PRESSURE 2. TRIM SHOWN FULLY ASSEMBLED;COMPONENTS SUCH AS GAUGES AND ALARM SWITCHES MAY REQUIRE ASSEMBLY IN TRIM AT INSTALLATION. 0SWITCH SYSTEM AIR SUPPLY 1/2 INCH NPT SYSTEM 4 INCH(DN100) CONTROL VALVE CONNECTION AIR SUPPLY MODEL DPV-1 ... (NORMALLY FOR SYSTEM PRESSURE DRY PIPE VALVE ' OPEN) AIR SUPPLY GAUGE (FxG SHOWN) CoMifin'- 3/4 INCH NPT 1 INCH NPT\ FLANGE ADAPTER • ,' CONNECTION y 4 if FOR WATER CONNECTION � OR GROOVED _ FOR LOCAL COUPLING ;, $ MOTOR ALARM SPRINKLER ` i I ' O , (.. ����1' WATERFLOW 'f�c. MAIN As �� PRESSURE 3/4 INCH NPT _- DRAIN VALVE a0� 1y�����Cl CONNECTION o (NORMALLY �V Imo" �, ALARM TO DRAIN/ CLOSED) iy\. �- `V 1/2 INCH NPT SWITCH 10 / ,:� ' CONNECTION ALARM / .I, FOR OPTIONAL TEST VALVE \ 2 INCH NPT U ACCELERATOR (NORMALLY SYSTEM LOW BODY CONNECTION CLOSED) SYSTEM SHUT-OFF DRAIN VALVE TO DRAIN AUTOMATIC WATER VALVE (NORMALLY SUPPLY (NORMALLY DRAIN VALVE CLOSED) PRESSURE OPEN) 1-1/4 INCH NPT GAUGE CONNECTION DRIP TO DRAIN FUNNEL FIGURE 4-PART 1 OF3 4 INCH(DN100)MODEL DPV-1 DRY PIPE VALVE PRE-TRIMMED ASSEMBLY `� 1 1/2 INCH NPT AIR SUPPLY CONNECTION CONTROL VALVE FOR OPTIONAL (NORMALLY ►,. ACCELERATOR OPEN) 1/2 INCH NPT MAIN <`,. CONNECTION SYSTEM DRAIN VALVE Q 1/2 INCH AUTOMATIC AIR SUPPLY (NORMALLY CONNECTIONION DRAIN VALVE FOR OPTIONAL AIR PRESSURE PRESSURE CLOSED) FOR WATERFLOW 1 GAUGE PRESSURE ALARMSLOPE SWITCH DOWN SWITCH 1 / _ D 3/4 INCH NPT �.1 1111 { /r co \ h CONNECTION 01"' � 1r `� FOR WATER - ,! A - MOTOR ALARM mi l`z ' �� - \ `�1$, / Oa \ 0y �� sf�� i��y���,,� '� psi 2 INCH NPT 1/2 INCH NPT I>i' �I01 I OW ' 1 ? CONNECTION CFOR SYSTEMN I ti� �1 0 / / r. > TO DRAIN FOR SYSTEM \ AIR SUPPLY U ,A74.,•, C`o:,I i i �' tt w ''Ft ', ' IPPPP',� 4 INCH(DN100) ALARM ' Oa 02 MODEL DPV-1 TEST VALVE DRY PIPE VALVE NORMALLY ,. \" (FxG SHOWN) (NORMALLY 1 INCH NPT NOTES: 3/4 B CONNECTION 1. INSTALL TRIM ASSEMBLIES IN INCH NPT SYSTEM FOR LOCAL ALPHABETICAL ORDER. CONNECTION WATER SUPPLY / SPRINKLER PRESSURE TO DRAIN 2. SEE FIGURE 2 FOR VALVE PORT GAUGE LOW BODY IDENTIFICATION. DRIP DRAIN VALVE 3. ROUTE 1/4"TUBING TO DRIP FUNNEL. FUNNEL 1-1/4 INCH NPT (NORMALLY 4. SLOPE ASSEMBLY B DOWN TOWARD CONNECTION CLOSED) BACK OF VALVE TO FACILITATE TO DRAIN SUFFICIENT LOW BODY DRAINAGE. FIGURE 4-PART 2OF3 4 INCH(DN100)MODEL DPV-1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF SEMI-ASSEMBLED TRIM TFP1020 Page 13 of 20 l NOTES: 47 16 48 1. SEE FIGURE 2 FOR VALVE PORT IDENTIFICATION. Y!tg 28 18 6 2. ROUTE 1/4"TUBING, ITEM 16, —Q 4 34 5 15 27 TO DRIP FUNNEL, ITEM 14. (GREEN 3. SLOPE 3/4"ANGLE VALVE, 9 29 y TINT) 18 12 ITEM 9,DOWN TOWARD SLOPE 34 14 BACK OF VALVE TO DOWN 34 FACILITATE SUFFICIENT 26 LOW BODY DRAINAGE. 8 34 19 if, 34 27 4. ALL FITTINGS AND NIPPLES 1 36 ARE GALVANIZED. LOCATION .� eP�� 1 FOR OPTIONAL 03D j\ 5. CH:COMMON HARDWARE Ore ELECTRICALLY r �� 32 17 13 6. ITEMS 45-48 INCLUDED SUPERVISED isriill yes, % c ONLY IN PRE-TRIMMED N.O.ALARM 41 , ►I 30 ., 3 VALVE ASSEMBLIES AS CONTROL p\l 39 40 lQ7 APPLICABLE;OTHERWISE VALVE 9 10 ��e 03 / SEPARATELY ORDERED. �� 39 04 23 \ Y1 �� 30 e�th 40 ```� e 4 INCH(DN100) 24 34 34 43 ifr� MODEL DPV-1 � I 01In DRY PIPE VALVE -ii.w 42 31A �� 011 I (FxG SHOWN) Ir 33 n •� ( 9 U f or .,:, 7 20 % Z , u r, 25 33 38 ` 0 46 (�A_ j l ,Hey �� ,,,1 ti It' �' 37 � io . ��� 2 i�,��j 0y 11 NO. DESCRIPTION QTY P/N r-N 22 ��� 44 1 250 psi/1750 kPa P8 / .` _ 3 45 Air Pressure Gauge 1 92-343-1-012 35 yY'W. 17 2 300 psi/2000 kPa 32 °" Water Pressure Gauge 1 92-343-1-005 3 1/4" Gauge Test NO. DESCRIPTION QTY P/N Valve 2 46-005-1-002 4 1/4"Pressure 21 1/2"x 1/4"Reducing Relief Valve 1 92-343-1-020 Bushing 1 CH NO. DESCRIPTION QTY P/N 5 1/2"Angle Valve.. .1 46-048-1-004 22 1/2" Union 1 CH 6 Model AD-1 23 3/4" Union 1 CH 41 3/4"x 2" 1 CH Automatic 24 1/2"90°Elbow....1 CH 42 3/4"x 3" 1 CH Drain Valve 1 52-793-2-004 25 1/2"45°Elbow....1 CH 43 1"x 4" 1 CH 7 1/2"Ball Valve . .. .1 46-050-1-004 26 1/2"Cross 1 CH 44 2"x 4-1/2" 1 CH 8 1/2"Swing 27 1/2"Tee 2 CH COMPONENTS INCLUDED ONLY IN Check Valve 1 46-049-1-004 28 1/2"x 1/4"x 1/2" PRE-TRIMMED VALVE ASSEMBLIES: 9 3/4"Angle Valve...1 46-048-1-005 Reducing Tee 2 CH 10 3/4"Swing 29 1/2"x 1/2"x 1/4" 45 Model BFV-300 Butterfly Check Valve 1 46-049-1-005 Reducing Tee 1 CH Valve,4"(DN100). .1 59300G040WS 11 2"Angle Valve . ...1 46-048-1-009 30 3/4"x 1/2"x 3/4" 46 Butterfy Valve 12 Drip Funnel Reducing Tee 3 CH Assembly Component: Connector 1 92-211-1-005 31 1"x 1"x 1/2" GxG DPV-1 Valves, 13 Drip Funnel Reducing Tee 1 CH Figure 577 Coupling, Bracket 1 92-211-1-003 PIPE NIPPLES: 4"(DN100) 1 57740ACP 14 Drip Funnel 1 92-343-1-007 32 1/4"x 3" 2 CH FxF,FxG DPV-1 Valves, 15 3/32"Vent 33 1/2"x Close 2 CH Figure 71 Flange Adapter, Fitting 1 92-032-1-002 34 1/2"x 1-1/2" 7 CH 4"(DN100) 1 7140S 16 1/4"Tube, 35 1/2"x 2" 1 CH 47 Waterflow Pressure 24"Long 1 CH 36 1/2"x 2-1/2" 1 CH Alarm Switch, 17 1/4"Plug 2 CH 37 1/2"x 3" 1 CH Model PS10-2 1 25710 18 1/2"Plug 2 CH 38 1/2"x 3-1/2" 1 CH 48 Low Air Pressure 19 3/4"Plug 1 CH 39 3/4"x Close 2 CH Alarm Switch, 20 1" Plug 1 CH 40 3/4"x 1-1/2" 2 CH Model PS40-2 1 25730 FIGURE 4-PART 3OF3 4 INCH(DN100)MODEL DPV-1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF VALVE TRIM TFPIO2O Page 14 of 20 NOTES: 1. SEE FIGURE 5 PART 3 FOR TRIM ARRANGEMENT WITH BILL OF MATERIALS LOW AIR AND COMPONENT PART NUMBERS. PRESSURE 2. TRIM SHOWN FULLY ASSEMBLED;COMPONENTS SUCH AS GAUGES AND ALARM SWITCHES MAY REQUIRE ASSEMBLY IN TRIM AT INSTALLATION. SWITCH SYSTEM / 41, AIR SUPPLY SYSTEM !/, CONTROL VALVE AIR SUPPLY (NORMALLY • � OPEN) 1/2 INCH NPT PRESSURE �j CONNECTION GAUGE SYSTEM \ leer,,. LOW BODY FOR SYSTEM r- WATER ,�y�`,✓✓✓✓// w, AIR SUPPLY , �'1 SUPPLY t DRAIN VALVE %� PRESSURE i �`�\ (NORMALLY l / i„vi CLOSED) 1 INCH NPT Z�- 7>r GAUGE =1 ( �. _ CONNECTION „ ` � ),� AUTOMATIC FOR LOCAL Q`(;Ji (,•i GROOVED ��`��_- SPRINKLER �,,/ •I (es COUPLING ) ��� DRAIN VALVE �� � t,� OR FLANGE 141 ra0 �1j, i ` 1/2 INCH NPT DRIP FUNNEL �?� I�r�` ADAPTER '�� ;. ��>jt��`;\ '�� CONNECTION y6 �. ). r'� , �/ P •• 1 r��ra� FOR OPTIONAL MAIN ��) y, 1:0,1�./ ACCELERATOR DRAIN VALVE ALARM �� (NORMALLY 2 INCH NPT \ TEST VALVE 1-1/4 INCH NPT CLOSED) CONNECTION 6 INCH(DN150) SYSTEm SHUT-OFF (NORMALLY SED) WATERFLOW 3/41NCH NPT PRESSURE CONNECTION TO DRAIN MODEL DPV-1 CONNECTION ALARM TO DRAIN DRY PIPE VALVE VALVE FOR WATER (GxG SHOWN) (NORMALLY OPEN) MOTOR ALARM SWITCH FIGURE 5-PART 1 OF 3 6 INCH(DN150)MODEL DPV-1 DRY PIPE VALVE PRE-TRIMMED ASSEMBLY 1/2 INCH NPT 1/2 INCH NPT NOTES: B rl CONNECTION CONNECTION 4. SLOPE 3/4'ANGLE VALVE AND ��{ ., FOR OPTIONAL FOR SYSTEM 1 3/4"x 4-1/2"NIPPLE(OF ASSEMBLY B) QC�]li , AIR PRESSURE AIR SUPPLY mi/�_=• SYSTEM SWITCH INTO DRIP FUNNEL TO FACILITATE //////// AIR SUPPLY SUFFICIENT LOW BODY DRAINAGE. -- PRESSURE a AIR SUPPLY DRIP GAUGE \1 (4., CONTROL VALVE LOW BODY 1/2 INCH NPT FUNNEL-- (NORMALLY DRAIN VALVE CONNECTION SLOPE Atrrt Io/ 1 INCH NPT 0,� .4 OPEN) (NORMALLY FOR OPTIONAL TO FIT CONNECTION 1;0 I- CLOSED) ACCELERATOR 1/2 INCH NPT FOR LOCAL -. :���e CONNECTION A SPRINKLER r(1 . / AUTOMATIC FOR WATERFLOW „- l 40, DRAIN VALVE o o PRESSURE ALARM (ti �� p1 (if \ SWITCH 0 ��� �q B 3/4 INCH NPT MAIN J// \ CONNECTION DRAIN VALVE I O FOR WATER (NORMALLY CLOSED I p5 ♦III1 ���� �� ,I MOTOR ALARM ��� Or" i '�Cf �� / 2 INCH NPT D ���'�� 03 (t•f'� '•L CONNECTION 6 INCH(DN150)/ el '7 �/��� TO DRAIN MODEL DPV-1 DRIP --- DRY �� PIPE VALVE 1i1 ,.4; FUNNEL `C (FxF SHOWN) �✓ ,I� NOTES: •.. 0// •y 1. INSTALL TRIM ASSEMBLIES IN p2 �� s(t.rai p ' / 1 ALPHABETICAL ORDER. ` IJ , ,I' ,�fa \ ALARM 2. SEE FIGURE 2 FOR VALVE PORT 1-1/4 INCH NPT SYSTEM TEST VALVE IDENTIFICATION. CONNECTION WATER SUPPLY (NORMALLY 3. ROUTE 1/4"TUBING TO DRIP TO DRAIN PRESSURE CLOSED) FUNNEL. GAUGE FIGURE 5-PART 2OF3 6 INCH(DN150)MODEL DPV-1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF SEMI-ASSEMBLED TRIM TFP1020 Page 15 of 20 9 (,0 BACK OF 4 NOTES: 1. SEE FIGURE 2 FOR VALVE 4. ALL FITTINGS AND NIPPLES (((( -ems 1 VALVE 29 - PORT IDENTIFICATION. ARE GALVANIZED. 42 " //'°/►]'-�_AN (4 35 2. ROUTE 1/4"TUBING,ITEM 16, 5. CH:COMMON HARDWARE 14 ���'• r�?r 5 TO DRIP FUNNEL,ITEM 14. 6. ITEMS 45-48INCLUDED 18 - 3. SLOPE 3/4"ANGLE VALVE, ONLY IN PRE-TRIMMED ', 004 SLOPE-A 48 L�J > 1 ; ITEM 9,AND 3/4"x 4-1/2" VALVE ASSEMBLIES AS NIPPLE, ITEM 42,INTO APPLICABLE;OTHERWISE TO FIT sJ � 35 DRIP FUNNEL,ITEM 14,TO SEPARATELY ORDERED. 1 21 26 a�\1�� �/ 8 !/, . 40 FACILITATE SUFFICIENT 15 LOW BODY DRAINAGE. (GREEN LOCATION 3 = ��� 35 OG( 18 TINT) FOR OPTIONAL �° 9 (e r�i_ 35 ELECTRICALLY _ � r 30 i ���` 27 :,,, SUPERVISED 17 ON 33 33 r L� ` 35 42-- 6 ���,�, 16 ! 47 N.O.ALARM (l x� 43 p7 rr CONTROL Al 11 20 �. Ikrf35 31 28 37 rfr VALVE i�y Sr jir- 32 � 0 '�l �i4 40 31 �t ' J Ir // 44 1 al rare10 �("fr w 40 ti e10�\ //FCC " .. 1 % ` f 40 l cq' la 41 19 ,) ' P3 •• N► ry((e 6 INCH(DN150) 3 42 t 12 e`to MODEL DPV-1 DRY PIPE VALVE & 0 40 /yr�r (GxG SHOWN) Z, 1•1 \ 13 31 II (� 35 ,' 24 NO. DESCRIPTION QTY P/N �_�,��' 39 \ 14 38 7 34 1 250 psi/1750 kPa UZ 22 7 Air Pressure `(re 36 35 or" P5 Gauge 1 92-343-1-012 0 ,, 28 �,.� ) 2 300 psi/2000 kPa 2 r�!� nf`r ' 1 %`�o ' $ Water Pressure _ „ I Gauge 1 92-343-1-005 i � ' • 3 1/4"Gauge Test es :44i. 33 Valve 2 46-005-1-002 \.� Y 4 1/4" Pressure 46tk 3 Relief Valve 1 92-343-1-020 17 NO. DESCRIPTION QTY P/N 5 1/2"Angle Valve...1 46-048-1-004 45 35 1/2"x 1-1/2" 8 CH 6 Model AD-1 36 1/2"x 2" 1 CH Automatic 37 1/2"x 2-1/2" 1 CH Drain Valve 1 52-793-2-004 0 36 1/2"x 3" 1 CH 7 1/2" Ball Valve ....1 46-050-1-004 0 39 1/2"x 6" 1 CH 8 1/2"Swing /- 40 3/4"x 1-1/2" 5 CH Check Valve 1 46-049-1-004 ere; 41 3/4"x 2" 1 CH 9 3/4"Angle Valve...1 46-048-1-005 `ir 42 3/4"x 4-1/2" 2 CH 10 3/4" Swing 43 1"x 4° 1 CH Check Valve 1 46-049-1-005 44 2"x 4-1/2" 1 CH 11 2"Angle Valve ... .1 46-048-1-009 COMPONENTS INCLUDED ONLY IN 12 Drip Funnel PRE-TRIMMED VALVE ASSEMBLIES: Connector 1 92-211-1-005 NO. DESCRIPTION QTY P/N 13 Drip Funnel 45 Model BFV-300 Butterfly Bracket 1 92-211-1-003 25 1/2"45°Elbow....1 CH Valve,6"(DN150)..1 59300G060W5 14 Drip Funnel 1 92-343-1-007 26 1/2"Cross 1 CH 46 Butterfy Valve 15 3/32"Vent 27 1/2"Tee 2 CH Assembly Component: Fitting 1 92-032-1-002 28 1/2"x 1/4"x 1/2" GxG DPV-1 Valves, 16 1/4"Tube, Reducing Tee 2 CH Figure 577 Coupling, 24" Long 1 CH 29 1/2"x 1/2"x 1/4" 6"(DN150) 1 57760ACP 17 1/4"Plug 2 CH Reducing Tee 1 CH FxF,FxG DPV-1 Valves, 18 1/2"Plug 2 CH 30 3/4"90°Elbow....1 CH Figure 71 Flange Adapter, 19 3/4"Plug 1 CH 31 3/4"x 1/2"x 3/4" 6"(DN150) 1 7160S 20 1"Plug 1 CH Reducing Tee 3 CH 47 Waterflow Pressure 21 1/2"x 1/4"Reducing 32 1"x 1"x 1/2" Alarm Switch, Bushing 1 CH Reducing Tee 1 CH Model PS10-2 1 25710 22 1/2" Union 1 CH PIPE NIPPLES: 48 Low Air Pressure 23 3/4" Union 1 CH 33 1/4"x 3" 2 CH Alarm Switch, 24 1/2"90°Elbow. .. .1 CH 34 1/2"x Close 1 CH Model PS40-2 1 25730 FIGURE 5-PART 3OF3 6 INCH(DN150)MODEL DPV-1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF VALVE TRIM TFP1O2O Page 16 of 20 7-1/8" L 8-3/8" 14-7/8" 9-1/4" (180 mm) (213 mm) (380 mm) (235 mm) II MO j \Q 2-1/2&3 INCH ■ pQ gI]���m. [U■p=■iII I (DN65&DN80) •. � - VALVE ■-■ 20-7/16" �� - (520 mm) :pir. nn 16-1/8" I■■ (409,6 mm) 10*=II ��I�i`. I Q 1[ all 2-1/2 or 3 INCH .'.1�".:i•- 1 ler L, I: �IA�.�I VALVES I-���I -,]�®PQ ■ r Y' ALL -l�a�a=l %� L' 12" 9-5/8" 12" 14" (300 mm) (245 mm) r (300 mm) (355 mm) 1111 ma 4 INCH ■ Q;i■i.omir—t". - 1E11 ; .�:.'.-il I (DN100) - - = VALVE p.mm� �� ..� I I; FxF:18-3/16"(462 mm) ©14 -♦�\ . TIIV�M:=I� .•., ■-' FxG:18-1/4"(464 mm) I�' .;il��L.• l l-: i('10:1- 111.1 Wil. GxG: 18-5/16"(465 mm) l '7]��_• 1.11-II — ��` �� f' -,,w I - 1 ,I _�®m-I %� II � 1 . 1 _.i 11-1/2" 11-3/8" 15" 14-3/4" (290 mm) (289 mm) (380 mm) (375 mm) A r 6 INCH 1 =•— i`© imimmmmmim (DN150) illaiQ;! iii■� n, '� .,)''i:-'I ' VALVE s ■ ■ mop 14 '- ■E■ 1� 24-1/2" • • �� W. I I (620 mm) li 11 C•r�F' �D Q `71 (555,6 mm) Ha'. so /�II� r W -. �_-i I j IIIiti 1 -E _ UMW It l FIGURE 6-PART 1 OF2 MODEL DPV-1 DRY PIPE VALVE INSTALLATION DIMENSIONS, PRE-TRIMMED VALVE TFP1O2O Page 17 of 20 y 6-3/4" 8" 14-7/8" _ 9-1/4" (170 mm) (200 mm) (380 mm) (235 mm) • f S © 2-1/2&3 INCH O•s41'7si„ t 16-9/16" [4■pp•iiill 7 Egi (DN65&DN80) (420,7 mm) • VALVE _ ,2-1/4" AI (311,2 mm) • • un II 2-1/2or3INCH si 11 \�1�!1 VALVES •.� -. 6 •—• 0L '• �billi ' � ■ _'III ILL a (150 mm) — 12" 6" 12" 14" (300 mm) (150 mm) (300 mm) (355 mm) I © 4 INCH 1 CPO �■ ��i'1 17-1/4" i=S`�>>;;r_II ' (DN100) �•g � �� (440 mm) ■�l, , = VALVE i; FxF:13-5/8"(346,1 mm) :'''jmI ' FxG:13-11/16"(347,7 mm) ar1=1 \• ..), i I. GxG: 13-3/4"(349,3 mm) • , ---AL-4 -l- 'r - ----- �_. 2-1/2"(65 mm) f 11-1/2" 7-1/4" 15" 14-3/4' �-(290 mm) (190 mm) (380 mm) (375 mm) t 1 410 OIMIIIIIIIMONM= 6 INCH (DN150) ems.• — Q�!, — / VALVE CiiI �MI■Ii mm*u. 18-3/4" Mall i J:iii-ll �' (475 mm) s 1 (406,4 mm) 16 • •� eggI I FxF,FxG, an ..11.' or GxG W mew> <it, 4-1/2" J W (115 mm) I FIGURE 6-PART 2 OF2 MODEL DPV-1 DRY PIPE VALVE INSTALLATION DIMENSIONS, VALVE AND SEMI-ASSEMBLED TRIM TFP1020 Page 18 of 20 Care and Step 3. Verify that the DPV-1 Valve has operated,as indicated by the flow Nominal Torque Maintenance of water into the system and that all Valve Sizes lb-ft waterflow alarms operate properly. in. (N•m) (DN) The following procedures and inspec- Step 4.Close the system Main Control tions should be performed as indicated, Valve. 2-1/2 30 in addition to any specific requirements (DN65) (41) of the NFPA,and any impairment must Step 5. Reset the DPV-1 Valve in 3 30 be immediately corrected. accordance with the Valve Setting (DN60) (41) Procedure. Before closing a fire protection system Note: It is recommended that the4 30 main control valve for maintenance (DN100) (41) work on the fire protection system that requirement of NFPA 25 to annually inspect the inside of the valve be per- 6 55 it controls,permission to shut down the formed at this time and prior to reset- (DN150) (75) affected fire protection system must be ling the DPV-1 Valve. Refer to the obtained from the proper authorities Automatic Drain Valve Inspection sub- TABLE C and notify all personnel who may be section Steps 2 through 5 for insiruc- HANDHOLE COVER BOLTS affected by action. tions with regard to the inspection of MAXIMUM TORQUE The owner is responsible for the the Clapper Facing. inspection,testing,and maintenance of Quarterly Waterflow Alarm Test Gauge), and then after removing the their fire protection system and devices Procedure Handhole Cover, perform the follow- in compliance with this document, asing steps: well as with the applicable standards Testing of the system waterflow alarms of the National Fire Protection Associa should be performed quarterly.To test Step 1. Make sure that the Seat Ring tion (e.g., NFPA 25), in addition to the the waterflow alarm, open the Alarm is clean and free of any nicks or signifi- standards of any authority having juris- Test Valve, which will allow a flow of cant scratches. diction.Contact the installing contrac- water to the Waterflow Pressure Alarm Step 2. Remove the Clapper Assem- tor or sprinkler manufacturer regarding Switch and/or Water Motor Alarm. bly from the valve by first pulling out any questions. Upon satisfactory completion of the the Hinge Pin. test,close the Alarm Test Valve. Automatic sprinkler systems are rec- Step 3. Disassemble the Clapper ommended to be inspected, tested, Water Pressure Inspection Facing Retainer from the Clapper and maintained by a qualified Inspec- The Water Pressure Gauge is to be so that the Clapper Facing can be tion Service in accordance with local inspected monthly (per NFPA 25) to removed and inspected. Make sure requirements and/or national codes. ensure that normal system water pres- that the Clapper Facing does not show sure is being maintained. signs of compression set,damage,etc. The operational test procedure and Clapperlace the Facing waterflow pressure alarm test pro- Air Pressure Inspection Replace es f wear if there is cedure will result in operation of the The Air Pressure Gauge is to be Y 9 associated alarms. Consequently, inspected monthly (per NFPA 25) to Step 4. Clean the Clapper Facing, notification must first be given to the ensure that normal system air pressure Clapper,and Clapper Facing Retainer, owner and the fire department,central is being maintained. and then reassemble the Clapper station,or other signal station to which Automatic Drain Valve Inspection Assembly. the alarms are connected. The Automatic Drain Valve should be Step 5.Reinstall the Clapper Assembly Annual Operation Test Procedure inspected monthly (per NFPA 25) by with its Hinge Pin. Note:Unless otherwise noted, refer to depressing the plunger and check- to ensure that the Automatic Drain Step 6. Install Handhole Cover: Figure 3, 4, or 5 to identify functional ing trim components. Valve is not discharging water and/or a. Align Handhole Cover Gasket and air. A discharge of water and/or air is Handhole Cover in proper orien- Proper operation of the DPV-1 Valve an indication that the air and/or water tation with valve body(Ref. Figure (i.e.,opening of the DPV-1 Valve during seats are leaking, which could subse- 1)and hold in place a fire condition) should be verified at quently cause a false operation should least once a year as follows: the intermediate chamber become b. Apply LOCTITE No.242(orequiv- Step 1. If necessary, prevent water inadvertently pressurized. alent)to Hex Bolt threads from flowing beyond the riser by: If leakage is present, take the DPV-1 c. Insert Hex Bolts through Hand- . Valve out of service (i.e., close the hole Cover Gasket and Handhole Close the Main Control Valve Cover, hand-tighten into valve main control valve,open the main drain • Open the Main Drain Valve valve,close the air supply control valve, body • Open the Main Control Valve one turn remove the Dry Pipe Valve Accelerator d. Using crossdraw sequence to beyond the position at which water from service, as applicable, in accor- assure uniformity,wrench-tighten just begins to flow from the Main dance with its Technical Data Sheet Hex Bolts to appropriate torque Drain Valve (Refer to TFP1105 for the VIZOR or values(Ref.Table C) • Close the Main Drain Valve TFP1112 for the ACC-1), and open the e. Inspect to assure all Hex Bolts Inspector's Test Connection to relieve are securely tightened Step 2. Open the system Inspector's the system air pressure to 0 psig as Test Connection. indicated on the System Air Pressure TFP1020 Page 19 of 20 Limited Specify:6 in.DPV-1 Pre-Trimmed Valve Accessories Assembly, (specify) End Connection, Refer to Technical data Sheets describ- Warranty P/N(specify): ing the following accessories, as Flange x Flange 52-310-3-060 applicable. For warranty terms and conditions,visit Flange x Groove 52-310-3-460 Specify: Description, P/N(specify): www.tyco-fire.com. Groove x Groove 52-310-3-960 Model PS10.2 Potter Electric Waterflow Pre-Trimmed DPV-1 Assemblies Pressure Alarm Switch 25710 Ordering without Butterfly Valve (Ref.Potter Electric Technical Data Sheet) Specify:4 in.DPV-1 Pre Trimmed Valve Model PS40-2 Potter Electric Low Air Y Procedure Assembly without Butterfly, (specify) Pressure Alarm Switch (Ref.Potter Electric Technical Data Sheet)25730 End Connection, P/N(specify): Model WMA-1 Contact your local distributor for avail- Flange x Flange 52-310-4-040 Water Motor Alarm 52-630-1-001 ability.When placing an order. indicate Flange x Groove 52-310-4-440 (Ref.Technical Data Sheet TFP921) the full product name and Part Number Model AMD-1 (P/N). Specify:6 in.DPV-1 Pre Trimmed Valve Air Maintenance Device 52-324-2-002 Assembly without Butterfly, (specify) Mod Model zl Data Sheet TFP1221) Standard DPV-1 Dry Pipe Valve End Connection, P/N(specify): Air Maintenance Device 52.326.2-001 ANSI standard outside diameter(O.D.) Flange x Flange 52-310-4-060 (Ref.Technical Data Sheet TFP1231) pipe size with grooved or ANSI drilled Flange x Groove 52-310-4-460 Model AMD-3 flange end connections and NPT Nitrogen Maintenance Device....52-328-2-001 threaded ports. Standard Galvanized (Ref.Technical Data Sheet TFP1241) Semi-Assembled DPV-1 Trim Specify: (specify size) Model DPV-1 Replacement Valve Parts Dry Pipe Valve with(specify)End Con- Note: Valves with NPT threaded ports Specify: (description) for use with nections, P/N(specify): are intended for use with the Standard (specify size) Model DPV-1 Dry Pipe Galvanized Semi-Assembled DPV-1 Valve, P/N(see Figure 1). Groove x Groove, Valve Trim described in Figures 3, 4 ANSI 2.88 in.(73,1 mm)O.D.Grooves: and 5 of this document. Replacement Trim Parts 2-1/2 In.(DN65)G x G 52-310-1-925 Specify: p Groove x Groove, Specify: 2-1/2 and 3 in. DPV-1 P Y (description) for use with ANSI 3.50 in.(88,9 mm)0.D.Grooves: Semi-Assembled Galvanized Trim, (specify size) Model DPV-1 Dry Pipe 3 in.(DN80)G x G 52-310-1-930 P/N 52-309-2-005 Valve, P/N(see Figures 3,4,or 5). Groove x Groove, Other DPV-1 DryPipe Valves ANSI 4.50 in.(114,3 mm)O.D.Grooves: Specify: 4 in. DPV-1 Semi-Assembled P 4 in.(DN100)G x G 52-310-1-940 Galvanized Trim, P/N 52-309-2-001 Notes: Other DPV-1 Dry Pipe Valves Flange x Groove, are valves ordered with any combi- ANSI Flange x ANSI 4.50 In.(114,3 mm)0.D. Specify: 6 in. DPV-1 Semi-Assembled nation of flange drilling, pipe groove Groove: Galvanized Trim, P/N 52-309-2-002 outside diameter(O.D.), or port thread 4 In.(DN100)F x G 52-310-1-440 Flange x Flange, Optional Electronic Accelerator: specification not offered as Standard ANSI Flanges: DPV-1 Dry Pipe Valves. 4 in.(DN100)F x F 52-310-1-040 VIZOR Electronic Dry Pipe Groove xGroove, Accelerator(with Trim) Valves with NPT threaded ports are ANSI 6.62 in.(168,3 mm)0.D.Grooves: (Ref.Technical Data Sheet TFP1105) intended for use with the Standard 6 in.(DN150)G x G 52-310-1-960 Specify: VIZOR Electronic Dry Pipe Galvanized Semi-Assembled DPV-1 Flange x Groove, Valve Trim described in Figures 3, 4 ANSI Flange x ANSI 6.62 in.(168,3 mm)0.D. Accelerator for use with the 4 or 6 in. and 5 of this document. Valves with ISO Groove: TYCO Model DPV-1 Dry Pipe Valve threaded ports are intended for use 6 in.(DN150)F x G 52-310-1-460 Trim, P/N 52-312-3-001 Flange x Flange, with special order trim that is provided ANSI Flanges: Optional Mechanical Accelerator: by local distributors to meet the spe- 6 in.(DN150)F x F 52-310-1-060 Model ACC-1 Dry Pipe Accelerator cific needs of certain localities. Please Pre-Trimmed DPV-1 Assemblies (Ref.Technical Data Sheet TFP1112) contact your local distributor regard- with Butterfly Valve Specify: Model ACC-1 DryPipe ing valves and valve trim for specific P y localities. Specify: 2-1/2 in. DPV-1 Pre-Trimmed Accelerator, P/N 52-311-1-001, Valve Assembly,Grooved End Connec- and Galvanized Accelerator Trim Specify: (specify size) Model DPV-1 tions, P/N 52-310-3-925 for Model DPV-1 Dry Pipe Valve, Dry Pipe Valve with(specify) End Con- Specify:3 in.DPV-1 Pre Trimmed Valve P/N 52-311-2-010 nections and (specify NPT or ISO) Assembly, Grooved End Connections, Optional 600 PSI Water Pressure threaded ports, P/N (specify): P/N 52-310-3-930 Gauge: Other 2-1/2 in.(DN65)Valves Specify:4 in.DPV-1 Pre-Trimmed Valve Specify: 600 PSI Water Pressure with NPT Threaded Ports Assembly, (specify) End Connection, Gauge,P/N 92-343-1-004 Groove x Groove, ( P Y) 3.00 in.(76,1 mm)O.D. P/N (specify): Grooves 52-309-1-930 Flange x Flange 52-310-3-040 Flange x Groove 52-310-3-440 Groove x Groove 52-310-3-940 TFP1020 Page 20 of 20 Other 2-1/2 in.(DN65)Valves Other 4 in.(DN100)Valves Other 6 in.(DN150)Valves with ISO Threaded Ports with ISO Threaded Ports with ISO Threaded Ports Groove x Groove, Groove x Groove, Groove x Groove, ANSI 2.88 in.(73,0 mm)O.D. ANSI 4.50 in.(114,3 mm)O.D. ANSI 6.62 in.(168,3 mm)0.D. Grooves 52-309-1-920 Grooves 52-309.1-923 Grooves 52-309-1-925 Groove x Groove, Flange x Groove, Groove x Groove, 3.00 in.(76,1 mm)O.D. ISO Flange x ANSI 4.50 in.(114,3 mm)0.D. 6.50 in.(165,1 mm)O.D. Grooves 52-309-1-940 Groove 52-309-1-213 Grooves 52-309-1-945 Flange x Flange, Flange x Groove, Other 3 in.(DN80)Valves ISO Flanges 52-309-1-113 ISO Flange x ANSI 6.62 in.(168,3 mm)0.D. with ISO Threaded Ports Other 6 in. DN150 Valves Groove 52-309-1-215 Groove x Groove, ( ) Flange x Groove, ANSI 3.50 in.(88,9 mm)0.D. with NPT Threaded Ports ISO Flange x 6.50 in.(165,1 mm)0.D, Grooves 52-309-1-922 Groove x Groove, Groove 52-309-1-315 DN100 Valves 6.50 in.(165,1 mm)O.D. Flange x Flange, Other 4 in. (DN100) Grooves 52-309-1-935 ISO Flanges 52-309-1-115 with NPT Threaded Ports Flange x Groove, Flange x Groove, ANSI Flange x 6.50 in.(165,1 mm)0.D. ISO Flange x ANSI 4.50 in.(114,3 mm)O.D. Groove 52-309-1-435 Groove 52-309-1-253 Flange x Groove, Flange x Groove, ISO Flange x ANSI 6.62 in.(168,3 mm)O.D. AS Flange x ANSI 4.50 in.(114,3 mm)0.D. Groove 52-309-1-255 Groove 52-309-1-613 Flange x Groove, Flange x Groove, ISO Flange x 6.50 in.(165,1 mm)0.D. JIS Flange x ANSI 4.50 in.(114,3 mm)0.D. Groove 52-309-1-335 Groove 52-309-1-813 Flange x Groove, Flange x Flange, AS Flange s ANSI 6.62 in.(168,3 mm)O.D. ISO Flanges 52-309-1-133 Groove 52-309-1-615 Flange x Flange, Flange x Groove, AS Flanges 52-309-1-513 AS Flange x 6.50 in.(165,1 mm)0.D. Flange x Flange, Groove 52-309-1-635 Flange x Groove, JIS Flanges 52-309-1-713 JIS Flange x ANSI 6.62 in.(168,3 mm)O.D. Groove 52-309-1-815 Flange x Groove, JIS Flange x 6.50 in.(165,1 mm)O.D. Groove 52-309-1-635 Flange x Flange, ISO Flanges 52-309-1-135 Flange x Flange, AS Flanges 52-309-1-515 Flange x Flange, JIS Flanges 52-309-1-715 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 ����� a 251E Johnson Controls.All rights reserved.All specifications and other information shown were current as at document revision date and are subject re change without notice. Johnson NATIONAL FIRE PROTECTION ASSOCIATION and rFPA ere regiCered IredemaCS of National Frte Protection Association, Controls ry LOCTITE lea,eghtered trademark of Henkel Caaretion Cho Worldwide www.tyco-fire.com Contacts Series TY-FRB - 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General to corrosive atmospheres. Although _ y. corrosion-resistant coated sprinklers Description have passed the standard corrosion � � (` jp tests of the applicable approval agen- ,� The TYCO Series TY-FRB 2.8,4.2,5.6, cies, the testing is not representative n i,. and 8.0 K-factor Upright, Pendent, of all possible corrosive atmospheres. i 1 ' and Recessed Pendent Sprinklers Consequently, it is recommended that described in herein are quick response, the end user be consulted with respect + I �' i to the suitability of these coatings for ,A standard coverage, decorative 3 mm $ glass bulb-type spray sprinklers.They any given corrosive environment. The are designed for use in light or ordinary effects of ambient temperature, con- — hazard,commercial occupancies such centration of chemicals, and gas/ as banks, hotels, and shopping malls. chemical velocity, should be consid- ered,as a minimum,along with the cor- The TY-FRB Recessed Pendent Sprin- rosive nature of the chemical to which I kler, where applicable, is intended for the sprinklers will be exposed. use in areas with a finished ceiling.This An intermediate level version of the •:, recessed pendent sprinkler uses one of Series TY-FRB Pendent Sprinklers ' the followingRecessed Escutcheons: ' is detailed in Technical Data Sheet • A two-piece Style 10 (1/2 in. NPT) TFP356.Sprinkler Guards are detailed or Style 40 (3/4 in. NPT) Recessed in Technical Data Sheet TFP780. Escutcheon with 1/2 in.(12,7 mm)of recessed adjustment or up to 3/4 in. NOTICE (19,1 mm) of total adjustment from The Series TY-FRB 2.8, 4.2, 5.6, the flush pendent position. and 8.0 K-factor Upright, Pendent, Sprinkler • A two-piece Style 20 (1/2 in. NPT) and Recessed Pendent Sprinklers p or Style 30 (3/4 in. NPT) Recessed described herein must be installed Identification Escutcheon with 1/4 in. (6,4 mm)of and maintained in compliance with recessed adjustment or up to 1/2 in. this document and with the applicable Number (SIN) (12,7 mm) of total adjustment from standards of the National Fire Protec- the flush pendent position. tion Association (NFPA), in addition to TY1131 .. .Upright 2.8K,1/2 in.NPT The adjustment provided by the the standards of any authorities having TY1231 . . Pendent 2.8K,1/2 in.NPT Recessed Escutcheon reduces the jurisdiction.Failure to do so may impair TY2131 . . .Upright 4.2K,1/2 in.NPT accuracy to which the fixed pipe drops the performance of these devices. TY2231 . . Pendent 4.2K,1/2 in.NPT to the sprinklers must be cut. The owner is responsible for maintain- TY3131 . . .Upright 5.6K,1/2 in.NPT Corrosion-resistant coatings, where ing their fire protection system and TY3231 . . Pendent 5.6K,1/2 in.NPT applicable, are utilized to extend the devices in proper operating condition. TY4131 . . .Upright 8.0K,3/4 in.NPT life of copper alloy sprinklers beyond The installing contractor or sprinkler TY4231 .. Pendent 8.0K,3/4 in.NPT what would be obtained when exposed manufacturer should be contacted with TY4831 .. .Upright 8.0K,1/2 in.NPT any questions. NFPA 13 prohibits installation of 1/2 in. TY4931 . . Pendent 8.0K,1/2 in.NPT IMPORTANT t t f with K- factors NPT sprinklers -acors greater Refer to Technical Data SheetTechnical TFP2300 for warnings pertaining to than 5.6 in new construction. They are regulatory and health information. intended for retrofit in existing sprinkler Data systems only. Always refer to Technical Data Approvals Sheet TFP700 for the "INSTALLER UL and C-UL Listed WARNING"that provides cautions FM,LPCB,and NYC Approved with respect to handling and instal- lationofsprinklersystemsandcom- See Tables A, B, C and D for complete onents. Improper and approval information including corrosion- Phandling resistant status. installation can permanently damage a sprinkler system or its compo- Maximum Working Pressure nents and cause the sprinkler to fail See Table E to operate in a fire situation or cause it to operate prematurely. Page 1 of 12 DECEMBER 2020 TFP171 TFP171 Page 2 of 12 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 7 - Bushing 7 1'r l 1 7/16" riT.:0 (11,1 mm) = '. 3 gal MAKE!EN- 2-1/4" ��� 2 1_r 2-3/16" (57,2 mm)/ I (55,6 mm) l� 1-9/16" 1Iiii� 4 I Ore 1/2" NPT** f WRENCH STYLE 10 or 20 2-7/8"(73,0 mm)DIA. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY1131)AND PENDENT(TY1231)SPRINKLERS 2.8 K-FACTOR, 1/2 IN. NPT *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1 doll 3 7/16" '':u•r (11,1 mm) A NOMINAL 2-3/16" �.I`� 2 MAKE-IN i (55,6 mm) 4 r�r 2-3/1m6 III 1-1/2" 4i� (55,tmm) . (38,i�mm) . 5 1/2"NPT** WRENCH 6* STYLE 10 or 20 2-7/8"(73,0 mm)DIA. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY2131)AND PENDENT(TY2231)SPRINKLERS 4.2 K-FACTOR, 1/2 IN. NPT Discharge Coefficient Poly-Stainless Design K=2.8 GPM/psi%(40,3 LPM/bar'") Physical Characteristics K=4.2 GPM/psi%(60,5 LPM/bares) Frame Bronze K=5.6 GPM/psi%(80,6 LPM/bars=) Button L316 Stainless Steel" Criteria K=8.0 GPM/psis=(115,2 LPM/bari) Bulb Glass Compression Screw L316 Stainless Steel' The TYCO Series TY-FRB 2.8,4.2,5.6, Temperature Rating Deflector Copper/Bronze and 8.0 K-factor Upright, Pendent, See Tables A and B Sealing Assembly.Gold Plated Beryllium Nickel and Recessed Pendent Sprinklers are w/TEFLON intended for fireprotection systems Finishes 'Type L316 stainless steel(UNS 31603)per ASTM Y Sprinkler:See Table D A479/410M or BS EN 1008WN1.4404. designed in accordance with the stan- Recessed Escutcheon:Signal or Pure White, dard installation rules recognized by Grey Aluminum,Jet Black,Chrome Plated, Operation the applicable Listing or Approval or Natural Brass The glass bulb contains a fluid that agency, such as UL Listing based on Physical Characteristics expands when exposed to heat.When Athe requiremenbasets of Neer 13 and FM Frame Bronze the rated temperature is reached, the the FMal Global on the requirements Data Button Brass/Copper of the . ly Loss stPyle 20, Data Sealing Assembly..Beryllium Nickel w/TEFLON fluid expands sufficiently to shatter the Sheets.Use only the style 10,20,30,or Bulb Glass glass bulb, allowing the sprinkler to 40 Recessed Escutcheon, as applica- Compression Screw Bronze activate and water to flow. ble,for recessed pendent installations. Deflector Copper/Bronze Bushing(K=2.8) Bronze TFP171 Page 3 of 12 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on 2 - Button Assembly Screw Deflector. special request. ESCUTCHEON 4 - Bulb 6 - Deflector* PLATE SEATING SURFACE 1 7/16" IA .! T (11,1 mm) ,•; - NOMINAL //0 � 2 MAKE-IN 2-3/16" �1�r Ai i (55,6 mm) I rimi 2-3/16" 1-1/2" ��� 4 (55,6 mm (36,1 mm) (`�5 111 i ;i.PI • o elf_,_..-- 6* 1/2" NPT** WRENCH STYLE 10 or 20 2-7/8"(73,0 mm)DIA. - FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 1/2" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated I SURFACE 4 - Bulb 6 - Deflector* on Deflector. Si% ift..1 \ 7/16" F E 3 iur= (11,1 mm) L-__ ;I�p MAKE-IN L 2-3/16"r � (55,6 mm)2-,6 m 1-1/2"(55,6 mm) (38,1 mm) f��5 �.�:� ti-�if� 6* } STYLE 10 1_ 2-7/8"(73,0 mm)DIA. - RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION POLY-STAINLESS FINISH ONLY FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY3131)AND PENDENT(TY3231)SPRINKLERS 5.6 K-FACTOR, 1/2 IN. NPT Installation of the sprinkler.Do not attempt to corn- Series TY-FRB Recessed Pendent pensate for insufficient adjustment in Sprinklers The TYCO Series TY-FRB 2.8,4.2,5.6, the escutcheon plate by under-or over- The Series TY-FRB Recessed Pendent and 8.0 K-factor Upright,Pendent,and tightening the sprinkler. Re-adjust the Sprinklers must be installed in accor- Recessed Pendent Sprinklers must position of the sprinkler fitting to suit. dance with the following instructions: be installed in accordance with this Series TY-FRB Upright and Pendent Step 1.After installing the Style 10,20, section. Sprinklers 30, or 40 Mounting Plate, as applica- General Instructions The Series TY-FRB Upright and ble,over the sprinkler threads and with Do not install any bulb type sprinkler Pendent Sprinklers must be installed pipe-thread sealant applied to the pipe if the bulb is cracked or there is a loss in accordance with the following threads,hand-tighten the sprinkler into of liquid from the bulb. With the sprin- instructions: the sprinkler fitting. kler held horizontally,a small air bubble Step 1.Install pendent sprinklers in the Step 2. Tighten the sprinkler into the should be present.The diameter of the pendent position. Install upright sprin- sprinkler fitting using only the W-Type 7 air bubble is approximately 1/16 in. klers in the upright position. Recessed Sprinkler Wrench,see Figure (1,6 mm) for the 135°F (57°C) and 15. With reference to Figure 1 to 4, 3/32 in.(2,4 mm)for the 286°F(141°C) Stepled to the 2. With pipe threads s thread ea halant apply the W-Type 7 Recessed Sprinkler pl - temperature ratings.A leak-tight 1/2 in. tighten the sprinkler into the sprinkler Wrench to the sprinkler wrench flats. NPT sprinkler joint should be obtained fitting. Step 3.After the ceiling is installed or by applying a minimum-to-maximum the finish coat is applied, slide on the torque of 7 to 14 lb-ft(9,5 to 19,0 N•m). Step 3. Tighten the sprinkler into the Style 10, 20, 30, or 40 Closure over A leak tight 3/4 in. NPT sprinkler joint sprinkler fitting using only the W-Type 6 the Series TY-FRB Recessed Pendent should be obtained with a torque of Sprinkler Wrench(Ref. Figure 14).With Sprinkler and push the Closure over the 10 to 20 lb-ft(13,4 to 26,8 N•m).Higher reference to Figure 1 to Figure 5,apply Mounting Plate until its flange comes in levels of torque can distort the sprinkler the W-Type 6 Sprinkler Wrench to the contact with the ceiling. inlet and cause leakage or impairment sprinkler wrench flats. TFP171 Page 4 of 12 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector, special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1 1/2" / NOMINAL I k� 3 (121/mm) 1I MAKE-IN 2-5/16" ��� 2 i (58,7 mm) 1 (57,2/mm) IP 1-9/16" 410 -- 4 \ 1 -5 ** f STYLE 30 or 40 6 * 3/4" NPT WRENCH FLATS RECESSED2-7/8"(73,0 mm)DIA. UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 3/4° ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated SURFACE 4 - Bulb 6 - Deflector* on Deflector. firrPrir,,117) — / li (12,7 mm) 1� 014 NOMINAL ��� ii.. 2 MAKE-IN 2-5/16" ,�- t�r ipii (58,7 mm) .t i 4 / (57,2 mm) . (39,7 mm) .� - --- - STYLE 40 � 2-7/8"(73,0 mm)DIA. RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION POLY-STAINLESS FINISH ONLY FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4131)AND PENDENT(TY4231)SPRINKLERS 8.0 K-FACTOR,3/4 IN.NPT CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 1 3 - Sealing 6 - Deflector* rr r1a'YT—vi I1 Assembly gill� 7M N 2-1/4" _____ 4 F 3 4 - Bulb (11,1 mm) NOMINAL (57,2 mm) A 2 MAKE-IN I * Temperature rating is 1�1 2-3/16" i 1-9/16" 4 indicated on Deflector. (55,6 mm) (30,7 mm) . ���—5 ** Pipe thread connections \ -_--�-- _,,,+r,`\ per ISO 7-1 can be 1 -6 * provided on special 1/2" NPT** WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4831)AND PENDENT(TY4931)SPRINKLERS 8.0 K-FACTOR, 1/2 IN. NPT TFP171 Page 5 of 12 2-7/8"DIA. _ 2-7/8"DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) 1/2±1/8" (73,0 mm) 1/2"(12,7 mm) (15,9±6,4 mm) 1/4"(6,4 mm) (12,7±3,2 mm) 1/4"(6,4 mm) 2-1/4"DIA. 2-1/4" DIA. / FACE OF (57,2 mm) MOUNTING / FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE 1/8" ii---- FITTING FITTING / (3,2 mm) (3,2 mm) 1 I TT_j �41_ �! �'� r 7, j 'I, ��`— MOUNTING ,,JMOUNTINGMSURFACE MI SURFACE r r' iy!r•'IoN ' CLOSURE SERIES 1-5/16"(33,3 mm) CLOSURE SERIES 1-5/16"(33,3 mm) TY-FRB 13/16"(20,6 mm) TY-FRB 1-1/16"(27,0 mm) FIGURE 6 FIGURE 7 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 IN. NPT 2.8 K-FACTOR, 1/2 IN.NPT 2-7/8" DIA. _ _ 2-7/8"DIA. _ 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) 1/2±1/8" (73,0 mm) 1/2"(12,7 mm) (15,9±6,4 mm) 1/4"(6,4 mm) (12,7±3,2 mm) 2_1/4"DIA 1/4"(6,4 mm) 2-1/4"DIA. . / FACE OF ~ (57'2 mm) �1 MOUNTING / FACE OF (57,2 mm) 1 MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" (3,2 mm) / (3,2 mm) mil III TT ]-_7--� vrr at 1 f 0, 7 lal./ ���� � MOUNTING141/ MOUNTING ■ SURFACE . SURFACE .. .. .. SERIES 1-1/4"(31,8 mm) SERIES 1-1/4"(31,8 mm) CLOSURE CLOSURE TY-FRB 3/4"(19,1 mm) TY-FRB 1'(25,4 mm) FIGURE 8 FIGURE 9 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 IN. NPT 4.2 K-FACTOR, 1/2 IN. NPT TFP171 Page 6 of 12 2-7/B"DIA. 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) 1/2±1/8' (73,0 mm) 1/2"(12,7 mm) (15,9±6,4 mm) 2-1/4"DIA. 1/4"(6,4 mm) (12,7±3,2 mm) 2-1/4"DIA. 1/4"(6,4 mm) / FACE OF (57,2 mm) MOUNTING / FACE OF (57,2 mm) SPRINKLER MOUNTING PLATE SPRINKLER PLATE FITTING FITTING / 2 m / 1/8' (3,2 mm) (3,2 mm) GA I.i , T c=1 I) F777i. ___ UNTING \ , MOUNTING II, P MSUURFACE _ � _. SURFACE +II CLOSURE SERIES 1-1/4"(31,8 mm) CLOSURE SERIES 1-1/4"(31,8 mm) TY-FRB 3/4" (19,1 mm) TY-FRB 1"(25,4 mm) FIGURE 10 FIGURE 11 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 IN. NPT 5.6 K-FACTOR, 1/2 IN. NPT 2-7/8"DIA. _ _ 2-7/8"DIA. 5/8±1/4" - (73,0 mm) 3/4"(19,1 mm) 1/2±1/8" (73,0 mm) 1/2"(12,7 mm) (15,9±6,4 mm) 2-1/4" DIA. y 1/4"(6,4 mm) (12,7±3,2 mm) 2-1/4"DIA. 1/4"(6,4 mm) / (57,2 mm) / (57,2 mm) FACE OF MOUNTING FACE OF MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING / 1/8" 1/8" (3,2 mm) / (3,2 mm) 1. P77 r. 1 \ i MOUNTINGi. / ILL 7,), j + la_MOUNTING SURFACE Ili SURFACE I , CLOSURE SERIES 1-5/16"(33,3 mm) CLOSURE SERIES 1-5/16"(33,3 mm) TY-FRB 13/16"(20,6 mm) TY-FRB 1-1/16"(27,0 mm) FIGURE 12 FIGURE 13 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR,3/4 IN. NPT 8.0 K-FACTOR, 3/4 IN. NPT WRENCH RECESS WRENCH RECESS l (END"A"USED FOR ^ 1/2"NPT MODELS) 1.) t ,�WRENCH RECESS (END'13"USED FOR PUSH WRENCH 3/4" NPT MODELS) INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 14 FIGURE 15 W-TYPE 6 SPRINKLER W-TYPE 7 RECESSED WRENCH SPRINKLER WRENCH TFP171 Page 7 of 12 Sprinkler Finish5 K-Factor Type Temperature Bulb Liquid Color Natural Chrome Plated Polyesters Brass 135°F(57°C) Orange 155°F(68°C) Red Pendent 175°F(79°C) Yellow (TY1231) 200°F(93°C) Green 286°F(141°C) Blue 1,2,3,4 135°F(57°C) Orange 155°F(68°C) Red Upright(TY1131) 175°F(79°C) Yellow 2.8 200°F(93°C) Green 1/2 in.NPT 286°F(141°C) Blue 135°F(57°C) Orange Recessed Pendent 155°F(68°C) Red (TY1231)a 175°F(79°C) Yellow Figure 6 200°F(93°C) Green 1,2,4 135°F(57°C) Orange Recessed Pendent 155°F(68°C) Red (TY1231)b 175°F(79°C) Yellow Figure 7 200°F(93°C) Green NOTES a. Installed with Style 10(1/2 in.NPT)or Style 40(3/4 in.NPT)3/4 in.Total Adjustment Recessed Escutcheon,as applicable. b. Installed with Style 20(1/2 in.NPT)or Style 30(3/4 in.NPT)1/2 in.Total Adjustment Recessed Escutcheon,as applicable. c. Frame and Deflector only. 1_ Listed by Underwriters Laboratories,Inc_,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed,the sprinklers are UL and C-UL Listed as corrosion-resistant sprinklers. TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 K-FACTOR SPRINKLERS TFP171 Page 8 of 12 Sprinkler Finish3 Bulb Liquid K-Factor Type Temperature Color Natural Chrome Plated Polyesters Brass 135°F(57°C) Orange 155°F(68°C) Red Pendent 175°F(79°C) Yellow (TY2231) 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange 155°F(68°C) Red Upright(TY2131) 175°F(79°C) Yellow 4.2 200°F(93°C) Green 1/2 in.NPT 286°F(141°C) Blue 1,2 135°F(57°C) Orange Recessed Pendent 155°F(68°C) Red (TY2231)a 175°F(79°C) Yellow Figure 8 200°F(93°C) Green 135°F(57°C) Orange Recessed Pendent 55°F(68°C) Red (TY2231)b 175°F(79°C) Yellow Figure 9 200°F(93°C) Green NOTES a. Installed with Style 10(1/2 in.NPT)or Style 40(3/4 in.NPT)3/4 in.Total Adjustment Recessed Escutcheon,as applicable. b. Installed with Style 20(1/2 in.NPT)or Style 30(3/4 in.NPT)1/2 in.Total Adjustment Recessed Escutcheon,as applicable. c. Frame and Deflector only, L Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers, 2. Listed by Underwriters Laboratories,Inc,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed,the sprinklers are UL and C-UL Listed as corrosion-resistant sprinklers. TABLE B LABORATORY LISTINGS AND APPROVALS FOR 4.2 K-FACTOR SPRINKLERS TFP171 Page 9 of 12 Sprinkler Finish8 Bulb Liquid K-Factor Type Temperature Color Natural Chrome Polyester Poly-Stainless° Lead Brass Plated Coated 135°F(57°C) Orange 155°F(68°C) Red Pendent 175°F(79°C) Yellow 1,2,3,4,5,6,7 1,2 1,2,3,5 (TY3231) 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange 155°F(68°C) Red Upright 175°F(79°C) Yellow 1,2,3,5,6 1,2 1,2,3,5 (TY3131) 200°F(93°C) Green 1 1/25.6in. 286°F(141°C) Blue NPT 135°F(57°C) Orange Recessed 155°F(68°C) Red Pendent (TY3231)a 175°F(79°C) Yellow 1,2,4,5 1.2 N./Ad Figure 10 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange Recessed 155°F(68°C) Red Pendent 175°F 79°C Yellow 1,2,3,4,5 N/A N/A (TY3231)b ( ) Figure 11 200°F(93°C) Green 286°F(141°C) Blue NOTES a. Installed with Style 10(1/2 in.NPT)or Style 40(3/4 In.NPT)3/4 in.Total Adjustment Recessed Escutcheon,as applicable. b. Installed with Style 20(1/2 in.NPT)or Style 30(3/4 in.NPT)1/2 in.Total Adjustment Recessed Escutcheon,as applicable. c. Frame and Deflector only. d. Not available(N/A). 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use In Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board(LPCS Ref.No.007k/04)as Quick Response Sprinklers.However,[PCB does not rate the thermal sensitivity of recessed sprinklers.5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved(For details,contact Johnson Controls,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377.) 7. Approved by the Loss Prevention Certification Board(LPCS Ref.No.094a/06)as Quick Response Sprinklers. 8. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers.Where Lead-Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. TABLE C LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS TFP171 Page 10 of 12 Sprinkler Finish8 K-Factor Type Temperature Bulb Liquid Color Natural Chrome polyester= Poly-Stainless= Lead Brass Plated Coated 135°F(57°C) Orange 155°F(68°C) Red Pendent 175°F(79°C) Yellow (TY4231) 200°F(93°C) Green 286°F(141°C) Blue 1,2,3,4,5,6,7 1;2 1,2,5 135°F(57°C) Orange 155°F(68°C) Red Upright 175°F(79°C) Yellow (TY4131) 200°F(93°C) Green 8.0 286°F(141°C) Blue 3/4 in. NPT 135°F(57°C) Orange Recessed 155°F(68°C) Red Pendent 175°F(79°C) Yellow 1,2,5 1,2 N/Ad (TY4231) Figure 12 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange Recessed 155°F(68°C) Red Pendent 175°F(79°C) Yellow 1,2,3,5 N/A N/A (TY4231)b Figure 13 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange 155°F(68°C) Red Pendent 175°F(79°C) Yellow (TY4931) 200°F(93°C) Green 8.0 286°F(141°C) Blue 1/2 in. 1,2,4,5,6 N/A 1,2,5 NPT 135°F(57°C) Orange 155°F(68°C) Red Upright 175°F(79°C) Yellow (TY4831) 200°F(93°C) Green 286°F(141°C) Blue NOTES a. Installed with Style 10(1/2 in.NPT)or Style 40(3/4 In.NPT)3/4 In.Total Adjustment Recessed Escutcheon,as applicable. b. Installed with Style 20(1/2 in.NPT)or Style 30(3/4 in.NPT)1/2 in.Total Adjustment Recessed Escutcheon,as applicable. c. Frame and Deflector only. d. Not available(N/A). 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)es Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/04)as Quick Response Sprinklers.However,LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved(For details,contact Johnson Controls,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377.) 7. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06)as Quick Response Sprinklers. 8. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers.Where Lead-Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. TABLE D LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFP171 Page 11 of 12 Sprinkler Finish K-Factor Type Natural Chrome Polyester Lead Coated Brass Plated Pendent(TY1231) and 2.8 Upright(TY1131) 1/2 in. 175 psi(12,1 bar) N/A2 NPT Recessed Pendent(TY1231) Pendent(TY2231) and 4.2 Upright(TY2131) N/A 1/2 in. 175 psi(12,1 bar) NPT Recessed Pendent(TY2231) Pendent(TY3231) and 5.6 Upright(TY3131) 250 psi(17,2 bar) 1NPT or 175 psi(12,1 bare Recessed Pendent(TY3231) Pendent d Y4231) 175psi 8.0 Upright(TY4131) (12,1 bar) 3/4 in. 175 psi(12,1 bar) NPT Recessed N/A Pendent(TY4231) 8.0 Pendent(TY4931) 175 psi 1/2 in. and 175 psi(12,1 bar) (12,1 bar) NPT Upright(TY4831) NOTES 1. The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories Inc.(ULt the Listing by Underwriters Laboratories,Inc.for use in Canada(C-UL);and,the Approval by the Clty of New York. 2. Not available(N/A). TABLE E MAXIMUM WORKING PRESSURE Care and corrosive products of combustion,but tion Service in accordance with local have not operated,should be replaced requirements and/or national codes. Allaintenance if they cannot be completely cleaned Care must be exercised to avoid by wiping the sprinkler with a cloth or damage to the sprinklers before, The TYCO Series TY-FRB 2.8,4.2,5.6, by brushing it with a soft bristle brush. during, and after installation. Sprin- and 8.0 K-factor Upright,Pendent,and Care must be taken to avoid damage klers damaged by dropping, striking, Recessed Pendent Sprinklers must be to the sprinklers before, during, and wrench twist/slippage,or the like,must maintained and serviced in accordance after installation. Sprinklers damaged be replaced.Also,replace any sprinkler with this section. Before closing a fire by dropping, striking, wrench twist/ that has a cracked bulb or that has lost protection system main control valve slippage,or the like,must be replaced. liquid from its bulb. For more informa- for maintenance work on the fire pro- Also, replace any sprinkler that has tion,see Installation section. tection system that it controls, obtain a cracked bulb or that has lost liquid Initial and frequent visual inspections of permission to shut down the affected from its bulb.For more information,see random samples are recommended for fire protection systems from the proper Installation section. corrosion-resistant sprinklers to verify authorities and notify all personnel who The owner is responsible for the the integrity of the corrosion-resis- may be affected by this action. inspection,testing,and maintenance of tant material of construction. There- Absence of the outer piece of an their fire protection system and devices after, annual inspections per NFPA 25 escutcheon, which is used to cover in compliance with this document, as should suffice. Inspections of corro- a clearance hole, can delay sprinkler well as with the applicable standards sion-resistant sprinklers are recom- operation in a fire situation. of the National Fire Protection Associ- mended at close range,instead of from Sprinklers which are found to be ation such as NFPA 25, in addition to the floor level per NFPA. Inspection at leaking or exhibiting visible signs of the standards of any other authorities close range can better determine the corrosion must be replaced. having jurisdiction.Contact the install- exact sprinkler condition and the long- ing contractor or sprinkler manufac- term integrity of the corrosion-resistant Automatic sprinklers must never be turer regarding any questions. material,which can be affected by the painted, plated, coated, or other- Automatic sprinkler systems are rec- corrosive conditions present. wise altered after leaving the factory. ommended to be inspected, tested, Modified sprinklers must be replaced. and maintained by a qualified Inspec- Sprinklers that have been exposed to TFP171 Page 12 of 12 P/N 57 — XXX — X — XXX I � SIN TEMPERATURE SPRINKLER RATINGS FINISH 330 2.8K UPRIGHT(1/2 in.NPT) TY1131 135 135°F(57°C) 1 NATURAL BRASS 331 2.8K PENDENT(1/2 in.NPT) TY1231 POLY-STAINLESS GREY 155 155°F(68°C) 2 ALUMINUM(RAL9007)1 340 4.2K UPRIGHT(1/2 in.NPT) TY2131 POLYESTER 175 175°F(79°C) PURE WHITE 341 4.2K PENDENT(1/2 in.NPT) TY2231 3 POLYESTER(RAL9010)2 200 200°F(93°C) SIGNAL WHITE 370 5.6K UPRIGHT(1/2 in. NPT) TY3131 4 POLYESTER(RAL9003) 286 286°F(141°C) JET BLACK 371 5.6K PENDENT(1/2 in.NPT) TY3231 5 POLYESTER(RAL9005)3 390 8.0K UPRIGHT(3/4 in. NPT) TY4131 7 LEAD COATED 391 8.0K PENDENT(3/4 in.NPT) TY4231 9 CHROME PLATED 360 8.0K UPRIGHT(1/2 in.NPT) TY4831 NOTES 1. Available only on TY3131,TY3231,TY4131,and TY4231 2. Eastern Hemisphere sales only. 361 8.0K PENDENT(1/2 in.NPT) TY4931 3. Available in only 2.8K,4.2K,and 8.0K.155'F 168°C)and 200°F(93°C);requires longer lead time to manufacture. TABLE F SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for www.tyco-fire.com. availability. When placing an order, indicate the full product name and Part Number(P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB (Specify SIN), (specify K-factor), (specify Pendent or Upright)Sprinkler(specify)temperature rating, (specify) finish or coating, P/N (specify from Table F) Recessed Escutcheon Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N (specify`) Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 1400 Pennbrook Parkway,Lansdale,PA 19446I Telephone+1-215-362-0700 02020Johnson Controls.All rights reserved.All specifications and ether information shown were current as of document revision date and are subject to change without notion. Johnson �J14,\(I NATIONAL FIFE PROTECTION ASSOCIATION and NFPA ere registered,ndemerhsCI Net°nal Fire Pretedlnn Aeseciellm; Controls TEFLON I.0 registered trademark°I P,PonI ` r1 CO® Worldwide www.tyco-fire.com Contacts Series TY-FRL - 5.6 K-factor Horizontal Sidewall Sprinkler Quick Response, Standard Coverage General Sprinkler Description Identification t TYCO Series TY-FRL 5.6K Horizon- Numbers (SINS) , �'. c tal Sidewall Sprinklers (HSW), Quick Response,Standard Coverage are sol- TY3321 —HSW 5.6K, 1/2 In.NPT der-type spray sprinklers designed for TY3321 is a re-designation for Star SIN use in light and ordinary hazard com- 61878 and Gem SIN G8946. mercial occupancies such as banks, hotels, shopping malls, offices, etc. Technical They are designed for installation along a wall or the side of a beam and just Operation beneath a smooth ceiling. Horizontal Data sidewall sprinklers are commonly used Approvals The fusible link(heat collector)assem- j roya instead of pendent or upright sprin- pp bly is comprised of two halves that UL and C-UL Listed klers due to aesthetics or building con- FM and NYC Approved are joined together by a thin layer of struction considerations,where piping solder. When the rated temperature is across the ceiling is not desirable. (Refer to Table A for complete approval reached, the solder melts and the two information.) link halves separate,allowing the sprin- NOTICE Maximum Working Pressure kler to operate. The Series TY-FRL Sprinklers 175 psi(12,1 bar) Design described herein must be installed Discharge Coefficient and maintained in compliance with this K=5.6 gpm/psi' (80,6 Ipm/bar1/2) Criteria document,as well as with the applica- ble standards of the National Fire Pro- Temperature Ratings tection Association(NFPA),in addition Refer to Table A TYCO Series TY-FRL 5.6K HSW Sprin- fo the standards of any other authori- Finishes klers, Quick Response, Standard Coverage are intended for fire pro- ties having jurisdiction.Failure to do so Refer to Table A may impair the performance of these tection systems designed in accor- devices. Physical Characteristics dance with the standard installation Frame Bronze rules recognized by the applicable The owner is responsible for main- Strut MONEL listing or approval agency (e.g., UL taining their fire protection system Deflector Bronze Listing is based on NFPA 13 require- and devices in proper operating con- Link RookAssembly MONEL Nickel ments); however, the minimum dis- dition. Contact the installing contraC Ejection Spring NCONEL tance between sprinklers to prevent for or product manufacturer with any Button Bronze cold soldering is 8 ft (2,4 m). The questions. Seal TEFLON Series TY-FRL HSW Sprinklers must be installed with a deflector- to-ceiling distance of 4 in. to 6 in. (100 mm to 150 mm). To meet this requirement the centerline of the IMPORTANT sprinkler waterway must be located Refer to Technical Data Sheet 4-5/16 in. to 6-5/16 in. (110 mm to TFP2300 for warnings pertaining to 160 mm)below the ceiling.Installation regulatory and health information. of the Series TY-FRL HSW Sprinklers Always refer to Technical Data in recessed escutcheons will void all Sheet TFP700 for the "INSTALLER manufacturer's warranties, as well as WARNING" that provides cautions possibly void the sprinkler's approvals with respect to handling and instal- and/or listings. lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 AUGUST 2018 TFP140 TFP140 Page 2 of 4 SPRINKLER FINISH K SPRINKLER TEMPERATURE FRAME FACTOR TYPE RATING COLOR CODE NATURAL CHROME BRASS PLATED 5.6 HORIZONTAL 165°F(74°C) Unpainted 1/2 in.NPT SIDEWALL 1,2,3,4 (TY3321) 212°F(100°C) White Notes: 1. UL Listed for light or ordinary hazard occupancies as Quick Response sprinklers 2. C-UL Listed for light or ordinary hazard occupancies as Quick Response sprinklers 3. FM Approved for light hazard occupancies Quick Response sprinklers 4. Approved by the City of New York under MEA 112-04-E TABLE A LABORATORY LISTINGS AND APPROVALS 1 - Frame 5 - Link 7 - Button *Temperature rating is indicated Installation 2 - Strut Assembly B - Seal on Deflector 3 - Deflector* 6 - Ejection **Pipe thread connections per TYCO Series TY-FRL 5.6K HSW Sprin- 4 - Hook Spring ISO 7-1 can be provided on klers,Quick Response,Standard Coy- special request erage must be installed in accordance with this section. General Instructions A leak-tight 1/2 in. NPT sprinkler joint 1-5/8" a _.�1/2" NPT** should be obtained with a torque of 7 to (41,3 mm) 1- 14 lb-ft. (9,5 to 19,0 N•m).A maximum 11 / °11,4, of 21 lb-ft. (28,5 N•m)of torque may be used to install sprinklers with 1/2 NPT WRENCH connections. Higher levels of torque DEFLECTOR* 6 FLANGES may distort the sprinkler inlet and 3.5° 3 4 5 2 7 WRENCH 8 1 cause leakage or impairment of the AREA CENTERLINE sprinkler. OF SPRINKLER Do not attempt to make-up for insuf- WATERWAY ficient adjustment in the escutcheon a— plate by under- or over-tightening the 1 - sprinkler. Readjust the position of the sprinkler fitting to suit. 5/16"(7,9 mm) NOMINAL Horizontal Sidewall Sprinklers Note: The Series TY-FRL HSW Sprin- 7/16"(11,1 mm) _y klers must be installed with their cen- NOMINAL MAKE-IN terline of waterway parallel to the DEFLECTOR ` ceiling and perpendicular to the back BOSS - 2" wall surface. The word "TOP"on the (50,8 mm) WALL PLATE SEATING deflector must face upwards toward 5/8" 2-11/16" SURFACE the ceiling. (15,9 mm)y (68,3 mm) Step 1.After installing an escutcheon FIGURE 1 (as applicable) over the sprinkler pipe QUICK RESPONSE threads and with pipe thread sealant SERIES TY-FRL(TY3321)HORIZONTAL SIDEWALL SPRINKLER applied to the pipe threads, hand 5.6 K-FACTOR, 1/2 INCH NPT tighten the sprinkler into the sprinkler fitting. Step 2. Tighten the sprinkler into the sprinkler fitting using only the W-Type 9 Sprinkler Wrench (Ref. Figure 2). WRENCH With reference to Figure 1,the W-Type RECESS 9 Sprinkler Wrench is to be applied to the wrench area. FIGURE 2 W-TYPE 9 SPRINKLER WRENCH TFP140 Page 3 of 4 P/N 58 - XXX - X - XXX SIN SPRINKLER TEMPERATURE FINISH RATING 946 5.6K HSW(1/2 in.NPT) TY3321 1 NATURAL 165 165°F(74°C) BRASS 9 CHROME 212 212°F(100°C) PLATED TABLE B SERIES TY-FRL HORIZONTAL SIDEWALL SPRINKLERS, QUICK RESPONSE PART NUMBER SELECTION Care and Limited Ordering Maintenance Warranty Procedure TYCO Series TY-FRL 5.6K HSW Sprin- For warranty terms and conditions,visit Contact your local distributor for avail- klers,Quick Response,Standard Coy- www.tyco-fire.com. ability.When placing an order,indicate erage must be maintained and serviced the full product name and Part Number in accordance with this section. (P/N). Before closing a fire protection system Sprinkler Assemblies with main control valve for maintenance NPT Thread Connections work on the fire protection system that Specify: Series TY-FRL 5.6K Quick it controls,permission to shut down the Response Horizontal Sidewall Sprin- affected fire protection system must be klers,SIN TY3321,(specify)temperature obtained from the proper authorities rating,(specify)finish,P/N(specify from and all personnel who may be affected Table B) by this action must be notified. Sprinkler Wrench Absence of an escutcheon, which is Specify: W-Type 9 Sprinkler Wrench, used to cover a clearance hole, may P/N 56-000-1-849 delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied or over-heated sprinklers must be replaced. Care must be exercised to avoid damage to the sprinklers before, during,and after installation.Sprinklers damaged by dropping,striking,wrench twist/slippage, or the like, must be re placed. The owner is responsible for the inspection,testing,and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction.Contact the install- ing contractor or product manufacturer with any questions. It is recommended that automatic sprinkler systems be inspected,tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes.