Permit 44 CITY OF TIGARD BUILDING PERMIT
_ COMMUNITY DEVELOPMENT Permit#: BUP2021-00184
T t G A R D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 8/12/2021
Parcel: 1 S135AB01004
Jurisdiction: Tigard
Site address: 10220 SW GREENBURG RD 150
Project: Spec Space Subdivision: METZGER,TOWN OF Lot: 9
Project Description: Tenant improvement to include interior demolition,new casework,ceiling,lights and finishes.
Contractor: RUSSELL CONSTRUCTION INC Owner: LINCOLN CENTER LLC
20915 SW 105TH AVE BY SHORENSTEIN PROPERTIES LLC
TUALATIN, OR 97062 235 MONTGOMERY ST, 16TH FLOOR
SAN FRANCISCO, CA 94104
PHONE: 503-692-9002 PHONE:
FAX: 503-692-9008
Specifics: FEES
Description Date Amount
Type of Use: COM
Class of Work: ALT Type of Const: IB Permit Fee-Additions,Alterations, 08/10/2021 $744.51
Occupancy Grp: B Occupancy Load: 35 Demolition
12%State Surcharge-Building 08/10/2021 $89.34
Dwelling Units: 0
Plan Review 07/27/2021 $483.93
Stories: 0 Height: 0 ft DC Provision Review,COM TI-Ping 08/10/2021 $110.00
Bedrooms: 0 Bathrooms: 0 Plan Review-Fire Life Safety 08/10/2021 $297.80
Value: $52,000 Info Process/Archiving-Lg$2.00(over 08/10/2021 $14.00
11x17)
Tigard CET-Non-Residential-Admin 08/10/2021 $20.80
Floor Areas: Tigard CET-Non-Residential-AH 08/10/2021 $499.20
Total Area: 0
Accessory Struct: 0
Basement: 0
Carport: 0
Covered Porch: 0
Deck: 0
Garage: 0
Mezzanine: 0
Total $2,259.58
Required: Required Items and Reports(Conditions)
Fire Sprinkler: Parapet:
Fire Alarm: Protected Corridors:
Smoke Detectors: Manual Pull Stations:
Accessible Parking: 0
This permit is issued subject to the regulations contained in the Tigard Municipal Code. State of OR. Specialty Codes and all other applicable law. All work
will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more
the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344_
Issued By: HoUy Vc.WDe'Weie Permittee Signature: O w A plicatfovt
Call 503.639.4175 by 7:00 a.m.for the next available inspection date. Y
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
r
Bidding Permit Application .' :.it .`,1 R I I::i-"ti -,:-]1 is ,
Commercial �i I j ` 7 ��, FOR OFFICE USE ONLY
Received y City of Tigard Date/By:e Z3/L/ Permit-1 LCp•2021_00 1 r1
III 't 13125 SW Hall Blvd.,Tigard,OR 97223 „ITl O 1"3 to 0 Plan Revie '
C Phone: 503.718.2439 Fax: 503.5981i I i(.n NG f I1!I,.!O"� Date/By: UU 9- Z,I Other Permit:
f 1 G 4 K U Inspection Line: 503.639.4175 Date Ready/By: EllSee Page 2 for
Internet: www.tigard-or.gov nficd/Mc , 6r Supplemental Information
TYPE OF WORK REQUIRED•DATA:1-AND 2-FAMILY DWELLING
❑Ncw construction E Demolition Permit fees*arc bascd on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
®Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the
CATEGORY OF CONSTRUCTION work indicated on this application.
El 1-and 2-family dwellingValuation: $
®Commcrcial�iodustrial
Number of bedrooms:
❑Accessory building ElMulti-family
El Master builder El Other:
Number of bathrooms:
JOB SITE INFORMATION AND LOCATION Total number of floors:
Job site address:2 Lincoln-10220 SW Greenburg Road New dwelling area: square feet
City/State/ZIP:Tigard,OR 97223 Garage/carport area: square feet
Suite/bldg./apt.no.:150 Project name:Vacancy Space Prep Covered porch area: square feet
Cross street/directions to job site:Project located north of SW Oak Street, Deck area: square feet
south of SW Locust Street and east of Greenburg Road Other structure area: square feet
REQUIRED DATA:COMMERCIAL-USE CHECKLIST
Subdivision: I Lot no.: Permit fees*are based on the value of the work performed.
Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all
equipment,materials,labor,overhead,and the profit for the
DESCRIPTION OF WORK work indicated on this application.
Work to include demolition,new casework,ceiling,lights,and finishes. Valuation: $$52,000.00
I Existing building area: 3,502 square feet
New building area: 3,502 square feet
® PROPERTY OWNER 0 TENANT Number of stories:
Name:Shorenstein Type of construction: I-B
Address:5335 Meadows Rd.,Suite 275 Occupancy groups:
City/State/ZIP:Lake Oswego,OR 97035
Existing: B
Phone:(503)412-4844 Fax:( ) New: B
0 APPLICANT ® CONTACT PERSON BUILDING PERMIT FEES*
Business name:Mackenzie (Please refer to fee schedule)
Structural plan review fee(or deposit):
Contact name:Katie Reinhart
FLS plan review fee(if applicable):
Address: 1515 SE Water Ave Suite 100
Total fees due upon application:
City/State/ZIP:Portland,OR 97214
Phone:(503)224-9560 Fax: :(503)228-1285 Amount received:
E-mail:kreinhart@mcknze.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES*
Commercial and residential prescriptive installation of
CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System.
Business name:Russell Construction Submit two(2)sets of roof plan with connection details
and fire department access,along with the 2010 Oregon
Address:20915 SW 105th Avenue Solar Installation Specialty Code checklist.
City/State/ZIP:Tualatin,OR 97062 Permit fee(includes plan review $180.00
and administrative fees):
Phone:(503)692-9002 Fax:( ) State surcharge(12%of permit fee): $21.60
CCB lic.:58918 Total fee due upon application: $201.60
Authorized signature: -1_--- This permit application expires if a permit is not obtained
within 180 days after it has been accepted as complete.
Print name:Katie Reinhart Date:07/14/2021 * Fee methodology set by Tri-County Building Industry
Service Board.
I:\Building\Permits\BUP-COMPennitApp.doc 02/24/2011 440-4613T(1l/02/COM/WEB)
i
s. I ,
11111 „ Building Division
Accessibility: Barrier Removal Improvement Plan
TIGARD
REQUIREMENT: OREGON REVISED STATUTE (ORS) 447.241.
(1) Every project for renovation,alteration or modification to affected buildings and related
facilities shall be made to insure that the path of travel to the altered area and the restroom,
telephones and drinking fountains are readily accessible to individuals with disabilities unless
such alterations are disproportionate to the overall alterations in terms of cost and scope.
(2) Alterations madc to the path of travel to an altered area may be deemed disproportionate to
the overall alteration when the cost exceeds twenty-five per-cent(25%).
VALUATION: Total of all renovation,alteration or modification being done,
excluding painting and wallpapering: [1] $ 52,000
MULTIPLIER(25%barrier removal requirement): x .25
TOTAL BUDGET FOR BARRIER REMOVAL: [2] $ 13,000
ELEMENTS: In choosing which accessible elements to provide under this section,priority shall be given
to those elements that will provide the greatest access. Elements shall be provided in the
following order:
(a) Parking $
(b) An accessible entrance: $
(c) An accessible route to the altered area: $
(d) At least one accessible restroom for each scx or a single unisex
restroom: $
(e) Accessible telephones: $
(f) Accessible drinking fountains:and, $
(g) When possible,additional accessible elements such as storage and
alarms: $
TOTAL(shall equal line [2] of Valuation Computation): $
I:\Building\Permits\BT P-COM Permit9pp.doc 03/03/2011
s
Building Division
Plan Submittal Requirements
TIGARD Commercial & Multi-Family-New,Additions or Alterations
1. SITE PLAN (fully dimensional, drawn to scale) labeled with:
A. ❑ map &tax lot# ❑ project name ❑ site address ❑ suite number
❑ zoning ❑ applicant name El phone number
B. North arrow.
C. Scale (architectural or engineering only).
D. Street names.
E. Setbacks.
F. Parking,including disabled access.
G. Finished floor elevations.
2. EROSION CONTROL PLANS AND DETAILS.
3. BUILDING PLANS: See the "Plan Submittal Requirement Matrix" for the number of
plans required based on submittal type (no redlines or tape-ons accepted).
All details listed below shall be incorporated into the plans:
A. Scale (architectural or engineering only).
B. Foundation plan.
C. Floor plan(s).
D. Cross sections.
E. Reflective ceiling plan.
F. Seismic bracing detail for suspended ceiling.
G. Roof plan.
H. Exterior elevations.
I. Structural calculations, plans, details and specifications.
J. Accessibility barrier removal worksheet.
K. Deposit - based on valuation of project.
4. EXTRA SET OF THE FOLLOWING:
A. Two (2) copies of site plan to include vicinity map.
B. One (1) copy of erosion control plan with details.
C. Fire Department Building Survey, and full set of architecture drawings.
1:\Building\Permits\BUP-COM PermitApp.doc 03/03/2011
f
lig • Building Division
Plan Submittal Requirement Matrix
T I G A R D Commercial & Multi-Family -New,Additions or Alterations
Type of Submittal # of Plans
(Includes new,additions and alterations.) Required at
Submittal
Demolition Permit 2
(site plan required showing location and square
footage of all buildings to be demolished)
Site Work 3
(must include location of all accessible parking)
Plumbing (site utilities) 2
Building 3
Fire Protection System 3
Mechanical 2
Plumbing (building fixtures)
2
Electrical 2
Plan review is dependent upon submittal of a completed application and plans.
After plan review approval, the Plans Examiner will contact the applicant to request
additional sets of plans for distribution purposes (for contractor, City of Tigard,Washington
County, and Tualatin Valley Fire & Rescue),if applicable.
I:\Building\Permits\BUP-COM PermitApp-doc 03/03/2011
City of Tigard
COMMUNITY DEVRT OPMENT DEPARTMENT
m Building Permit Review — Commercial - No Land Use
TIGARD
Building Permit #: 1 u Il' ZO 24 - O O I P`I
Site Address: 2. LiNcoc-IJ - (022o s i 6ceetzec Suite/Bldg#: /51D
Project Name: 9EZ- pkiC-e.
(Name of commercial business occupying the space. If vacant,enter Spec Space.)
Planning Review
Proposal: VA CA rcy Coo-- eel), ' ,i cJr I Y"I PKbv r1 -
Existing Business Activity:
Proposed Business Activity:
/erify site address/suite# exists and active in permit system.
er Terrace Neighborhood: ❑ Yes 2No
jerkning: Mli
ermined Use: Ia Yes ❑ No ❑ Spec Space
nfirm no land use required.
0 Business License:
Exists: ❑ Yes E No,applicant was provided a business license application
Notes:
Approved by Planning: *44A-4 —' Date: //Zr
Revisions (after Building Submittal only) Reviewer Date
Revision 1: 0 Approved ❑ Not Approved
Revision 2: 0 Approved ❑ Not Approved
Revision 3: ❑ Approved ❑ Not Approved
Building Permit Submittal
Original Submittal Date: 7//.5/2_i.
Site Plans: # "-
Building Plans: #
Building Permit#: a—Enter building permit# above.
Workflow Routing: gHi fanning ❑ Permit Coordinator 13'gnilding
Workflow Sign-off: g-S -off for Planning(include notes from planning review)
Route Application Documents: ding: original permit application,site plans,building plans,engineer and
beam calculations and trust details,if applicable, etc.
Notes:
By Permit Technician: Q/Yt(I ety Date: /23/2-/
1:\Building\Forms\BldgPennitRvw_COM_NoLandUse_111819.docx
1
Permit Coordinator Review
❑ Con ns "Met"prior to issuance of building permit
❑ Approved, Released: Date:
Notes:
Revisions (after Building Submittal only)
Revision Notice 1: Date Sent to Applicant:
Revision Notice 2: Date Sent to Applica .
Revision Notice 3: Date Sent to cant:
❑ SDC Fees Entered: Wa o Trans Dev Tax: ❑ Yes /A
igard Trans SDC: ❑ Yes ❑ N
Parks SDC: ❑ Yes ❑ N/A
0 OK to Is - 'ermit
A I 1 s ved by Permit Coordinator: Date:
1:1Building\Forms\BldgPermitRvw COM NoLandUse I11819.docx
Nikki Tuason
From: Nikki Tuason
Sent: Monday,July 19, 2021 11:39 AM
To: kreinhart@mcknze.com
Cc: #Building Permit Technicians;Agnes Lindor
Subject: 1 Lincoln - 10300 SW Greenburg Rd, 2 Lincoln - 10220 SW Greenburg Rd.
Good Morning—
We received the proposed tenant improvements for 1 Lincoln - 10300 SW Greenburg Rd Suite 380, and 2 Lincoln - 10220
SW Greenburg Rd. Suite 150 and I'm following up regarding the scope of work proposed for both of these projects.The
permit application states that this is a "vacancy space prep" does this mean that there is currently no tenant residing
within the suite and will be prepped for a new tenant? Will the space still be used as an office?
Thank you,
Nikki
Nikki Tuason
Assistant Planner
City of Tigard Community Development
13125 SW Hall Blvd.
Tigard, OR 97223
nikkit@tigard-or.gov