Loading...
Plans Markup Legend SPRINKLER SYMBOL DEFINITION COLOR/LINETYPE LEGEND z / \ SENJU Model RC-RES Residential Flat Concealed Pendent SS8464 BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). % o Delete Line /r\\'` v \ OO XXX-XX ® - - - 13 K=4.9, 162F° 7/16"Orifice,Maximum Spacing 16'x16' r_`i LINES-- I TEP_EVEL CONNECTIONS/SUPPLY. O w x } RC RES 16 Sprinkler head demand: 13 gpm @ 7.04 BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. a z MAXIMUM SPACING(TYP) +� 1/2"PIPE SIZE > g Add Line SPRINKLER MODEL(TYP) RECEIVED - a- O SENJU Model RC-RES Residential Flat Concealed Pendent SS8464 ��� =3/4"PIPE SIZE �,u T HEAD SYMBOL(TYP) ® _ - - 2 K=4.9, 162F° 7/16"Orifice,Maximum Spacing 18'x18' —— <ry w d Add Tee I Sprinkler head demand: 17 gpm @ 12 .� .; = 1"PIPE SIZE O N N; RC RE$18 ? J = 1-1/4"PIPE SIZE m i - . uaLLinz Add Elbow SENJU Model RC-RES205 Residential Flat Concealed Pendent SS8464 J >t z° ® - - - 1 K=4.9,205F°,7/16"Orifice,Maximum Spacing 14'x14' CITY OF TIGARD CI FY OF TIGARDSID N t '3 RC-RES-14-205 Sprinkler head demand: 13 gpm @ 7.04 _< 0 3 Add Coupling l , «-" -+3 I II �Ir�l( �i a►ARved bi I I I SENJU Model RC-RES205 Residential Flat Concealed Pendent SS8464 H;,m g a Add Head -@--'--0.3` 0 - - - 1 K=4.9,205F°,7/16"Orifice,Maximum Spacing 16'x16' Contitionally Approved [ J ....... • I I RC-RES-16-205 Sprinkler head demand: 14 gpm @ 8.2 For only the work as described in: g o� Delete Head _ _ 4 1st Floor z'y o `�o y 4 2nd Floor �� Fes-, zz�Op� I 6 3r0 Floor ;8 u, 3 I I 3 4thFloor PERMIT N . rh{r2o�•1 - coo � V�=o �, s�� Move HeadE"'"z� cox 6�mz ,'zhoz Foao" ;O; ,,, 17 TOTAL See Letter to: Follow [ j uy`�o < r�uy =z=z��o Note:All revisions must be reviewed by Uponor Attach O"a o s u Table F002-1 /7v 2 21 5 s 1 Gc"&At, � 0 `� "5, v,,8? z'=" z a0 Job Address: del f/Na�7+.1 �= Op}=U e Multipurpose Fire Safety Systems 8zzamc<-tom_ _F The Uponor Residential Fire Safety System is a residential fire protections By: , .G LI Date: �,-g o- 2% in q a o<, .;<¢ system installed in combination with the cold side of the domestic potable VV W S`e--3;,> <z F z 3" water system. Only licensed contractors trained by Uponor can install this f,=z z K,.e..<i c ,Q,,, oae.-�sf.'<-- system. J t,2aoo6a:ic7F F ,. w WhattodoifChangesareRequired i I ! /� Ti VIz -6Eec> yzau If any features or obstructions require the addition or deletion of sprinkler I 20A 20F f� c<8 d o 5-<z •i o z"o. heads,or significant relocation of sprinkler heads,contact the Uponor Design D6 I I z= u z w->,o F a _, Department to determine if observed changes require a redesign _ y-_ ______Y__� __, _ _ DECK'BOVE i z=N e - (888.594.7726). �® ( oa'�ao. FE,gLL�?� rT MOST HYDRAULICALLY REMOTE HEADS FLOOLABOVE y / ¢¢c m m a' m z i N '( 8-07-d SOHD a' 5`<u0 O0 v Deck 6-0asL _ o�o�moyoy��� o HEAD# GPM PRESSURE REQ'D AT STREET I.. J PROPERLY PROTECT AND I - t yz'r 4`�>a>> e u 1 HEAD H.4 17 54.65 g 20E --" I INSULATE PIPE TO MAINTAIN m `2.R.-5 ,..,=6�m� 2 HEAD H.3&H.2 26.2469 74.02 u D6'I �� \w ! �\ 1 OF 40°F PER NF A A MINIMUM E13D,TYPE © ,'„"E 3��ti t cq ' C �I� I WALL FINISH 3i"G.WB. Storage n4 zac am-`md w e ` �1 CEILING FINISH%- v1°,i>i„�-u<c<.�u z o'�a TYPE'X'G.W.B. Area I( �\ FIRAP BE ALL G.W.B. or WRAP BEAMS BELOW 1"AQUAPEX INTERLEVEL 3'-6" 4•2 �I-� -}-Y 1 1"AQUAPEX INTERLEVEL CEILING LEVEL Workshop ' S.1 MAIN SHUTOFF CONNECTIONS FROM N0-t CONNECTIONS FROM FI INSULATE FLOOR ABOVE SECOND FLOOR TO THIRD 5 -t-, FLOOR TO SECOND FLOOR 2'-5/2 VALVE LOCATION t „ItRoCr.- ca._ • / , 1 Car Y FLOOR 5 SHELVE Rb_ 1 j \�� ere by certify that this plan,specification, ' � 10 - arage or report was prepared by me or under my \ `* I {:0 \ BOLLARD ICO, direct supervision and that I am NICET o! P.ntr �1.— - 1 e P ® SYSTEM AQUAPEX TO Certified. . ,. / _ ,:o \ \vim_ TR / V't P WOOD MAX . gyp TT :® 1 7/4" I N 1.FT'�'� ' � RISER 8"(ADD a _ \ •MOVE STEPS r..,„,3,4-li\ `Np N _,.'_ _ 7• ► _, - ______ 1 \ si -'✓rUIRED PER SITEvi jE Tim W McDonald Date: Y _ J '7 ' /I ',' NICET Certification No.150393 \ 47 l I 1 sue•- m -Ax 2 TREADS -S_ .'''ter 1 a Water-Based Systems Layout-Level III Tfot7 Ti �' or "/, TYP ,. al . ,-{ m pi , i� 5 ��ss Certification Expires:lune 1,2022 RIN ,7 T. ` . ° E nT.49 4.48VAF p -»>;2 ,B" 3,y..,.mil `€ ■ ' QQRR �� 1 - /• �::/ NIA ov EE SHT.U24 1 S IP 4• . 1 1 1 F.. '., s ?:1 �' � FOR STAIR I r 1 ■ 1 Fa� .E F2Il x0 DETAILS 1 L ��;�7..,: ,.ffi �+t' m U Ni RC+R l 1. i / . i a f M a R�: T.54 I (- t..-. - KltFhe te,i; ^' _ o:, r( J, •6,0 „ l Z F n ry l' ,— • SfE SHT.U24\ - -- , T6- 0 . Ce a>rnNi,ary n l FOR STAIR i I '\ EI.UP'" ' z \"`RI,wrY 1'6 a ta7 vai"o t yl 3y # 11 52 �AllS ,�� 14R /I n ., t1111fR JJ Eft 1-1/4"AQUAPEX ill ' H-- i' ` ' _. f c I-_ - S&P 45- u C�'/ o .. p CURRENT STATIC 1 1/4"AQUAPEX RISER moo-roe TO SYSTEM -8" Is'-a 6�f \S� _ !0 j_ ��•i 18 {.L z tj¢vOi dWATER PRESSURE r , LOW WALLWT, / \ '� -`,.. 's,� �.�'; S 1 1 1 o- a Gam, u STATIC: 95 sl PRESSURE GAUGE I +39"ABOVE RADON +; 45` \', �: ■ • • �.F f z O ul D li— 1Y� , DUCTION �� � \ I •AV uuu¢am zpTO HOT WATER V/ O O o xuI1 1/4"PRV CASH ACME HEATER - (OR EQUIVALENT) P.ADON RED CTION SYSTEM < 1 -0y ►�/ - l� O e 1 \, I 0 0 En I �..� W 0. 6PSI LOSS FLOWING 26 GPM R,6,ySTEM H.12 Elk 1 J PRV Seto Pressure rrrlll �I JJ IVIn I r6l 17 Q1 Rc BE-s-1�" g 16 • �lJ ,.,' T.66 1"WATER METER _ FLOOR s— s—c \ `a , 1..�� 4,`I,,-I\$-16 �+ O NFPA 13D STANDARD LOSS k- 7 M.I.L. Suite • 0 3 3PSI LOSS FLOWING 26GPM I _ // a O o E CD INSULATE f '— -1 1 \ O' FLOOR OVER I ( ' I ,,, 0 / a } Q ;°f I- >m SHUT OFF VALVE �I UNHEATED / TX 1" Porches w F' CURB STOP ar S.1 I PACE I �� 8 P. -� m \iiI / L ABOVE IM ___ 9 I� EGRESS ' O c�e/ L.C. . m m , STREET - s 1 - - FLOOR ABOVE 7-04J XOx '▪ �+' i=J f Ci F- I II-11=11 + N N v z z LL =F�IISt1 I 5-01-0SL ( 7-0S�XOX ��i\ 1 1 SFtt GIZ R m Q p CORPORATION .,l `j'6` �� I I 7' D4 _...u 5 STOP SPSI LOSS ., j ��� mEN ROOF BELOW 1-- a 1=W w a o WATER ) �-_:III• gip 12 SECOND FLOOR 1 FIRST FLOOR MAIN 4< 100'OF u w E�=95' SHEET DESCRIPTION Euv=9s 1 1/4"AQUAPEX 35'OF F100 1/4" = lI_On1 F100 i/^,1/4" = lI_oEI FIRST AND S COND FLOOR F OOR 1"COPPER-K `t SHEET NUMBER 3� WATER SERVICE DETAIL 5 0 5 illinEellir 15 1/4"=1'-0" F10i NTS © UPONOR - CONFIDENTIAL F100 .... ._ I a Markup Legend SPRINKLER SYMBOL DEFINITION COLOR/LINETYPE LEGEND ^ BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). %MB z o Delete Line /��^��\��' \ / \ XXX-XX =BEEN LINES=INTERLEVEL CONNECTIONS/SUPPLY. O w v v BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. J T1 I -----MAXIMUM SPACING(TYP) Iwo .z. = 1/2"PIPE SIZE w^°f Add Line — — — — — SPRINKLER MODEL(TYP) �a� =3/4"PIPE SIZE i d '0 o T HEAD SYMBOL(TYP) C w Add Tee I 1 I == = 1"PIPE SIZE O _._. N = 1-1/4"PIPE SIZE J tl Add Elbow 1 t u LL N z Iza 1 tz9 Add Coupling F----I. 0 3 1 I 1 1 1 Wll rvii Add Head 1 m wl-`W; Delete Head -wl IJC 1- y~ ba�M 7 F.- = Move Head -O- -O- §yh Z <<a �ugir< Note:All revisions must be reviewed by Uponor m G f w z tc u ^",=i3i4So3 Table F002-1 dz22?.ea z C7gj Z 02' r.1m..-� Multipurpose Fire Safety Systems zzv�mo�oo �yo The Uponor Residential Fire Safety System is a residential fire protections d.g,.o a,u 2 F 2 0?3 a u system installed in combination with the cold side of the domestic potable W m u I y c,,42 z a}e water system. Only licensed contractors trained by Uponor can install this N 2 5�"�i 1=,,;h I,.,z c.; system. aFozzooX2y5'Wz What to do if Changes are Required U`a m o f.y c Eg'-'4. 6 v'�o ZE ''_ If any features or obstructions require the addition or deletion of sprinkler ►I a a d p"`"'�d o u „� heads,or significant relocation of sprinkler heads,contact the Uponor Design la t i m o,,,E c`i e R b o i Department to determine if observed changes require a redesign i'f c o.ti ii e o a oB F.o (888.594.7726). 0g� �E . 'cid ---;-=:--- /V/V /1 _ o��o�>i'�3u I •••FLOOR BELOW 9�'u y- zam`� ' I I 1/2"COLD WATER AQUAPEX II TVP. '® 4e . w a F 0 R-v c zo z,1 °C Q / I a g i=R2i (ATTIC) INTERLEVEL CONNECTION II \ 7 =h h F$<u 8 b o < ,n 5-6 8Si 7-15 SF AT J1� FROM THIRD FLOOR TO ATTIC - iI �� in—� 1—' 30'MIN/ ell Master ROOF ?�EGRESS LEARAE \ i I Bedroom BELOW / \ KCESS \ ( I I"I,4 .I there by certify that this plan,specification, / PER R807.1 y i (ATTIC) / ATTIC I / \ Aft 4 —J\3 RE 2-9' • or report was direct supervision preparedandthat I by me a or under my irk f ACCESS : ' Certified. TIF I HATCH DCIIEF -I 114'WAL. ,IC ES _ =Tr'-^-.-4 I I I / / BS4-6ELOWF D4 ` I viiiizw :. 42"34" 14 4 \ I 2 �f ER Tim W McDonald Date: q.) / ; an �" qr0 : NICter Certification No.150393 — (. ` _ _- Water-Based Systems Layout-Level III I / / \ LI C\ y I 4. 49 FTC .'.,�v Certification Expires:June 1,2022 D3 if D4 a H.V Ll ���"'"'\"' o 3/4 22N .Bath / R RES-14-205 'I�' _ ' p 24 N �°�, ACC ss / i , — ," f. I I• —_ -1 , v LLJ LL 1 5 ''�.''1L.�� SEE SHT.U2�r.lx' — 1"AQUAPEX INTERLEVEL • i4.-10' Ia�y�@ IC xo FOR STAIR V �' ;�63. >- r-c T --� CONNECTIONS FROM U t9 T24 T21, I T.19 _�@ — DETA IS ' l� L�„ Im ! / / / FLOORD FLOOR TO THIRD • W x En { — �2 / T.20 m �� r 5.9 _ _ a 0" o (,I \dV \ \SEE SS�T r lialpria�it- .3 4 - I Ce ,� N_ i T 2514 R I • \FOR.�TAIR"� I ABath- o,l ¢z n n H. 1 11 LO TA - o /// 11111111 jP.T U -40_TOWEL 45 FT ,- CI " RC RE71-1 ti 39"ABo ® I 6 • r, if K a W ¢ N o 1.-a NOSING - i Z / R✓.:'- - --I TUB& < \ /a/ ` LOW WALL ® / p Y 1 . ! ° SHOWER I- 1 `. / ` AT3 0 \ ' .- it T , _ ''I �.1 ............ 1"AQUAPEX INTERLEVEL / ( �' r m'\ 5&P 7 ' z o ..¢ O ��, --- CONNECTIONS FROM THIRD 1 --'S$� 1 - ,.,0/ Y G ~u 12 I L 22x307{1TICI1.3 FLOOR TO ATTIC I _ 2 r*.. _ 12 FT' ,. �, LL Q a a a w D4 CCESS HATCH 15 FT I S O R PASS i —N a W f z z p w SIM.RADON e T 1'� RC-RES-1�6` ` 4sIC(ATTIC) 4 THgNESS REDUCTION245E AT , i (AIIIQ , Jt.o) 3.-3 • Y 3'-"pi- 2'3)t 9Y8 1\.3.-SY• _/ W s e \ CLEARANCE, !!I v I"{ r fLyi \ / ACCESS /RC-RES-16 9%B( RC-RES-16 ' ' 0 0 5 TYP.@ �- / PER R807.1 -J DORMER EGRESS I ( Bedroom 3 O\Bedroom 2 / �; z �4 5-6 TOR I I I / Dl p� - /� > Q Y P d z ,m I r :1 O O ty m=�� _ m�m EGRESS / ........ /-�/ w ..�+ Q s I EGRESS 5-0 1-0 SI ..6.. o` (V (I't LI m m z o 5-O�SL I ROOFIBELOW , (5 / . y,3 V K G 2 \ ATTIC PLAN 1 THIRD FLOOR SHEET DESCRIPTION THIRD FLOOR AND ATTIC PLAN F.,io� 1/4" = ll_OII Fiol 1/4" = 11_011 SHEET NUMBER 0 5 15 16 1/4"=1'-0" © UPONOR - CONFIDENTIAL F101 Markup Legend SPRINKLER SYMBOL DEFINITION COLOR/LINETYPE LEGEND ismBLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). f o Delete Line I\ OO XXX-XX GREEN LINES= INTERLEVEL CONNECTIONS/SUPPLY. J /�!\�✓ �/ \ BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. O :•i° MAXIMUM SPACING(TYP) -^� =1/2"PIPE SIZE > ti Add Line - SPRINKLER MODEL(TYP) =3/4"PIPE SIZEC a oHEAD SYMBOL(TYP) �' a N Add Tee I T I =1"PIPE SIZE ® N u_ T = 1-1/4"PIPE SIZE a.'o Add Elbow L�J / W , W O I N 2 ozd rcLn�a ZaNj3 Add Coupling I---� t7-+,o.. m Add Head -0.1`-�--63- W w m a W O Fp,,F W3 I 1 1 a d gw d 1 Zi4 pwa a Delete Head - 3 y a•z z E Move Head -O- -O- n'a'ii'-' ''•❑go np 1 I mvmgzv EoEIH m Note:All revisions must be reviewed by Uponor ❑va,O=l_ Z 0 w n Table FOO2-1 de 2�op°,'6s - 'i- zEa�ar- m�=1-z-z Multipurpose Fire Safety Systems zzaoos� ❑- _ ° The Uponor Residential Fire Safety System is a residential fire protections p o c°z w o o! " system installed in combination with the cold side of the domestic potable W m p m 0 f a i- a o water system. Only licensed contractors trained by Uponor can install this F.i'<zp`'7 i- : ❑.''.i system. -.d5ozi oo,X¢g5z J .z _oDF°LaufcEo iz",y FQha�au" > F What to do if Changes are Required (A w 5111 t Y G p y u If any features or obstructions require the addition or deletion of sprinkler 1"AQUAPEX INTERLEVEL 1"AQUAPEX INTERLEVEL PROPERLY PROTECT AND 1".s F h a CCo a a u o y" heads,or significant relocation of sprinkler heads,contact the Uponor Design INSULATE PIPE TO MAINTAIN i w o z u u E o-z CONNECTIONS FROM CONNECTIONS FROM FIRST` I-.- d��?E••• Department to determine if observed changes require a redesign , SECOND FLOOR TO THIRD` II vn I �/ I / F••R TO SECOND FLOOR !, • A MINI UM TEMPERATUI�EP ',g E❑0 3 y l'?z-o i o (888.594.7726). FLOOR \ --- , - --------- }y '¢map❑w " ❑ r-- li OF 40° PER NFPA I3D o "�a fit- ROOFBELOW I // /k r DECK ABOVE 3op �aiL�aguauz< 1NT•COLD WATER NNECTIAQUAPEX • ,I 7-041xOx A \\\ FLOOR ABOVE Ll �/ � ,� ,® ❑�i z Y e=ypoo / INTERLEVEL CONNECTION ......... 5-0 n�osl Deck 111 olm E' ° aF FROM THIRD FLOOR TO ATTIC EG: // T L r t( Tt ' \� 1 1 a-07-(150 . �" °m❑ w m z m m/ I LOORSELOW 1 1 �\\\ r- o \ (.� �u v''-,' s'u Naa�'a a \I /Ip_ \ �TYP.II // / I 4 I �. ' ow j I ZD6E u �/ \\ ">�uy3u=•v'f, �oa6 / * 1 / / \._I— _ �J I \\ I, imawZoi'ioCawvmh W 15 SF ATI Sfi 3-0 SL I i / R, 6 4 i\ ,{/ -----A---- I / D' Stora e\\ WALL FIN H1)G.W.B. tan 30'MIN: \--1 r'-" bOP o Master I \ 1 / > CI) ; S.I' a' \ CEILI FINISH Pi, CLEARANCE, EGRESS BELOW - - ���JJJ••iii ) .:a+ffi'- q MAIN SHUTOFF Area \ TYP X G.W.B. NO I / \ - ,Bedroom I I' / �712 3•{• II VALV LOCATION or \ FIRES PE ALL G.W.B. i 't�tr'; L1.1 / WRA•BEAMS BELOW ACCESS80 \ H.4 V/ / 1 / "'a I Hilt 1 / \\ ILING LEVEL I here bycertify that this plan,specification, PER R8071 p \ I / \ Z5% CO3t-' / I I \ - III SHEL S --X,,, hOp\ • ATE FLOOR ABOVE or report was prepared by me orpunder my 22x30 (ATTIC) / 2`g 4 �- `� eal' F i • 1-1/4 AQUAPEX TOE--? 1 Car I direct supervision and that I am NICET ACC SS 8 I /li 0 I,(� \ 0 3., ry \- 's \\ p Certified. , 1 DORMER AL. CKNESS (Il..� • \ \ \ �? `I I'// I O �` ` aoe \ HATCH I- r g I 1 ,'Yd 4 • BOLLARD D4 BELOW ROOF � E�O I /I r .'1 .•41 �AII /= aNT I/ \ \ m - 16 - ..•ER 8'(ADD OR m " L I '� Tim W McDonald Date: . _ e' r.- S NICET Certification No.150393 \ .. ' • (�^' c% Y� ' -- -\ I I 1 4 ; R{ls( �� lair CertificationdExDsres:June 11,t2022Level III I t o e "�.�"•I F. R - REQUIRED PER S D NVI. m zn•Ta 49 FT. c� I I. a ,. , 4•i/ �s H.6 NP. "��R i; 1T47 - d• M 2TIVA• al Jita Ajakin - LLJ 9I I `--" '" A '.:r � r�al� f ./ F•13 " . , _ � I SEESHTU2 ie _77pp,, u ' :I SEE SHT.U24 iii r Y v it 14 G Lf Il ..T, �kII &DR 1 DETAILTr .--- 'Pu" - cr• yR�,� DETAILS STAIR z } T.19 L �T.�2Q1 T.24 P • 11� �SIN. _ . _ - _ F.127i�110 x T."_� !(!(!(������fJJ — I', 60 1 � i Q X IA - T.20 S 2� r3— 1 0 Y ITP\,5.-B. �1 ; I.Y 'Waal!" ��� 4 \ �.� � �I 9- u17 • y_ _ I /'1"I HH i u o n n_o /"FOR�TAIR \ I1 r� I BathO �. :� I T.54,(, ID,4. I I --o 'a Q. E.1 Ri 9-16 z ce DFTAILS I .2 i II 45 FF�TOWEL 2 s7 iMPIIIIII„ - I t174 �,I �����1' '.Im " y .7 N I I ____ K a Lao vaioOj L W W!(lL AT �. 1- IAIR zn .,I0) ( L W ABOVE ) • �"ES 16 •, SEE SHT. en tte .�i _( �,yy ALg ii� Ii SHOWER` '1i a•r �� ��� FOR STI.J "`r ���!li I 1 ., (/��1z O 471A i LUNOSING t� / 5 TUB R t S,� , I DET I '" D ::: •��a UP � I I I a',~NIgIC .,L03`WALE ��. '' 1 �i1 i .' 16 R I I\X ' UC a R r I S'-fi' 1 UP , 6 I74R H.3 r I �� m 5 4° 3A 5 S&P 1D Fr I a CC6SS�HAiCH\ � •�I \1 ' :rs, .. - ,,,, — �57' 1......:u4.43:y=r, I l' - R 1 ♦k LllLL OF O O o b O g m w 1 I SIM. \ S . ' •■� ,I"� V a a zz a zamSF a (�2C RES"16 (e� �REap` I .l� wP L /0 w 5-OB/PASS 4 ' II / b�C \ > ,--� >! THIC NSS0c NOS' l4 • t W REDOQ�ON .�' l� I X2• 1 2'-7' to 30"MIN. (ATTIC) SYSTEtv(�\ .�r1 �* I \ I / RADOMREDUCTION 1 e I �� x_�y' ." �i !CLEARANCE 1"AQUAPEX INTERLEVEL 3'-51/B' 3.-Ot/' .+.'B T-5y'f- t %B" 3'-3%g \ SYST[t� ( " \ i ; l'• Li. LU CONNECTIONS FROM THIRD Q �- \ / D4 \IFLOOR TO ATTIC / �•V 93�8�. \ H.12 Livin n.�� R p Entry Q,y, /II m RC-RES-16 1 P 1s o m o ACCESS \ RC-RES-16 RAG R�R I 7 �© Q 4 pC PER R807.1 ` TYP.CO ' / / I T.QC I O g EGRESS DORMER I \Bedroom 2 / Bedroom 3 I< 0- Y BFFLOW I VVV RC-Rik 6 •..... •• r _I DC .0 0 O \ 7 ` �{ f�.I.L.Suite / m a 5'6 SL ( /� D' ` / - ( r-\— —l� INSULATp 1i \\ NI } Q ,o O 1- m O' x I FLODR OVER I / 3.10Y21 } 2..y O f W to I ® r-- --- 1 -- T1k. / \ UNHEAT F - I 1 I / ® O rm p m to^a EGRESS WALLA VE A_ SPAC 1 1 Porch I�® 5-0�� • EGRESS I/`�.t 1 i I -'/ J )I �� .EGRESS 0l m '6 z W i ROOF LOW I 5-0 1-0 SL / 7-0 5-r,XOX 5-P 0 SL i y 7.015 XOX 88 FLOOR ABOVE r n I^ G 3 Wt. s Q I{} SPY GLZ I D7 v V' DS I _ RO�F BELOW Ii 0 (f ) go d O z ATTIC PLAN 3 THIRD FLOOR 2 SECOND FLOOR 1 FIRST FLOOR SHEET DESCRIPTION MIRRORED PLAN ALL FLOORS C4D 1/4" = lt_Oti F102 1/4" = 11-0Lt F102 1/4" = 1t_0It F102 1/4" = 11-0tt SHEET NUMBER 5 0 5 15 IW tiWL�.� IIM -_.--_ 1/4"=1•-0" © UPONOR - CONFIDENTIAL F102 yA uaSAFETM GENERAL NOTES: Senju RC-RES:Open Web Truss/TJI Construction Insulation Recommendations rtIn areas subject to freezing,care should be taken in unheated attic spaces See General Notes 8.2.5.8 for Architectural M ProPEX LF Brass Fire to cover Uponor AquaPEX tubing completely with insulation. Insulation Feature Requirements S Sprinkler Adapter Tee should follow the guidelines of the insulation manufacturer. See Uponor ` • f f 1. THIS SYSTEM IS DESIGNED AS PER NFPA 13D 2019 EDITION AS A RESIDENTIAL MULTIPURPOSE SYSTEM Blocking Maybe Fire Sprinkler Adapter Document"Uponor AquaSAFE Attic Insulation Guidlines"for attic SECTION 3.3.12.3. Pant-on Nut "N Required.If installation guidelines(Provided in Contractors Documents package or online Blocking is Used, .� 1 t/•"Min. at www.Uponorpro.com). i 1 0 > z 2. UPONOR COMPANY RESERVES THE EXCLUSIVE RIGHTS TO ALL DETAILS AND DRAWINGS AS SHOWN ON "r Use The 2 Top 1/ 1 "Max. nQ THESE DETAILSAND DRAWINGS ARE PROPRIETARY INFORMATION OF UPONOR COMPANY AND 2 w f THIS SHEET. Screw Holes. I ) ( ( Planter Box Window,BayWindow or Similar Feature. • UNAUTHORIZED USE MAY BE SUBJECT TO PROSECUTION TO THE FULL EXTENT OF THE LAW. �.. Bottom of Mounting Extreme Temperature Installations If no additinal floor area is created No Additional Sprinkler is Required. u ti @f racket to Pace of truss AquaSAFE Residential Fire Safety systems are often installed in attics or '¢3 w 3. THE DESIGN OF THIS SYSTEM IS DICTATED BY SPECIFIC CEILING HEIGHTS AND ROOM SIZES. IT IS THE Fire Sprinkler Adayte -� _. other areas exposed to temperature extremes of heat and/or cold. Follow 8'-0"or less L 0 -%ry u RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THE CONDITIONS SHOWN ON THESE Mounting BracketI `_-�_ • the recommended extreme weather installation instructions to isolate and / 1 • .142 a i PLANS ARE EXACTLY AS THEY EXIST IN THE FIELD. DEVIATIONS FROM THE DESIGN MAY CAUSE THE l protect system components from extreme temperatures. Because this RGRES-16 u w LL m z SYSTEM TO BE UNABLE TO CONTROL A FIRE.IF THE BUILDING CONSTRUCTION DIFFERS FROM THE FIRE • O system also delivers domestic cold water directly to plumbing Fixtures, ® o S 9'-0•or less i S ry z SPRINKLER PLAN,CONTACT THE SYSTEM DESIGNER IMMEDIATELY. 3-#10 x 1 1/2" ___ _ _ Uponor highly recommends that you protect the tubing with adequate / w W m n Full Course I insulation in warm weather areas to minimize heating of the cold water N£v 3 4. THIS SYSTEM AND THE ACCOMPANYING HYDRAULIC CALCULATIONS ARE DESIGNED IN COMPLIANCE WITH Thread Shrews b ' b- supply. o = Z o o'O 3 NFPA 13D 2019 EDITION. In Bottom Holes o= O.,'^.w 3 ---\ \ rso / '°\ 5. "STAND-ALONE"OR"MULTIPURPOSE,WET PIPE"SYSTEMS ARE PERMITTED TO ONLY USE ANTI-FREEZEInstallation methods include,but are not limited[o: ro o, Y • Tenting over the fire sprinkler piping. O m F w 3 LISTED FOR USE IN NEW SPRINKLER SYSTEMS. Concealed Lead-Free Flat ` _- Additional layers of batt insulation. If additional floor area is created.Cannot exceed 18 fe,be more than 2'-0" Concealed Senju \ 't" ''' -� Concealed Flat • Increased depth of blown-in Insulation. deep,more than 9'-0"wide and be with in the coverage area of the o w 6. MODIFICATIONS ARE PROHIBITED.SPRINKLERS THAT HAVE BEEN PAINTED,CAULKED,MODIFIED OR g a d Sprinkler Head Cover Plate sprinkler.No Additional Sprinkler is Required. z w o w`a'0 a DAMAGED MUST BE REPLACED. o y z��z ��� _ Caution: If you will be installing spray foam insulation,make sure to r 5 f m S _ $3 7. A SINGLE CONTROL VALVE ARRANGED TO SHUT OFF BOTH THE DOMESTIC SYSTEM AND THE SPRINKLER protect all components during application.Consult with the spray foam ii x p y 0 O m w SYSTEM SHALL BE INSTALLED. Senju RC-RES:Traditional Wood Framing Construction manufacturer to ensure compatibility with all products before application. NFPA 13D Table 7.5.6.3 Distances From ua9zd oy 09ao9 Heat Sources §yo�o<�� h w� 8. OWNERS MANUAL MUST BE PROVIDED TO THE OWNER. Consultation with local building officials is encouraged to ensure compliance H u,m"z-m z=4 F m o with local building codes. d000 °9uK034�Q gu 9. AT THE MAIN SHUT OFF VALVE,A TAG OR A SIGN STATING THE FOLLOWING IS REQUIRED;"WARNING:THE ProPEX LI'.Brass Fire Ordinary Intermediate ?:",+�y,�z ?� Fire Sprinkler Adapter c o n e o.0 z WATER SYSTEM FOR THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRE CERTAIN FLOWS AND Sprinkler Adapter Tee push-or Nut Heat Source Temp. Temp. 00 i"y O sal'= = PRESSURES TO FIGHT A FIRE.DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR - L 135*-170" 175•-225• z w 0 m a<c m AUTOMATICALLY SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM,SUCH AS WATER SOFTENERS, -`" _ BendingPEX Tubingg o Q o O da" FILTRATION SYSTEMS AND AUTOMATIC SHUT OFF VALVES,SHALL NOT BE ADDED TO THIS SYSTEM Side of 36" 12" -p z w WITHOUT REVIEW OF THE.FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST.DO NOT REMOVE 1 t/4'Min. The minimum bend radius of Uponor PIX tubing in any direction is six times Front of Fireplace 60" 36" W m o m m>y z Z z 3 0 1 'Max. the outside diameter(6 x OD). E m g z - a a w-• THIS SIGN". -" - Bottom cf MountieWood Burning Stove 42" 12" w a o a Fire Sprin der Adapter - �' Bracket to=ace of truss Bend supports are available for 3/8",1/2",3/4"and 1"Uponor AquaPEX Kitchen Range 18" 9" i r-p z z o o s a v,0 z 10. ALL INTERIOR PIPING TO BE UPONOR• uerPEX®"UNLESS NOTED. Mounting Bracket \\Z 1 tubing to facilitate 90-degree rigid bends. g g barn .o p�'i i a f E O l '�� Wall Oven 18" 9" V..z--,w`t a 11. UPONOR"AquaPEX"TUBING TO BE SUPPORTED PER NFPA 13D AND MANUFACTURER'S RECOMMENDATIONS. 2-#10 x 1 1/2" 0 I 0 Recommended Tubing Length Between Fittings Hot Air Flues 18" 9" w a 6 0 0, z Q Y w gs,. , .4„10nyu q Full Course --..-.. _- 1---1 - - } FittingSize Minimum TubingLength Uninsulated Heat Ducts 18" 9" m "°'w xF F-3 12. BED EN SPRINKLERS UM SPACING SAND FROM EEN IWALLS.SPRINKLERNKLERS IS 8,0" EHEAD MANUFER TO FACTURERS MAY HAVE MORE G CHARTS FOR MAXIMUM SPACING In TopThread Hales Screws l Uninsulated Hot Water Pipes 12" 6" m 0 c z ,ry g c 0 7,,'9 o V b 3/8"ProPEX Fitting 2" z g 3 u, z e o y F RESTRICTIVE SPACING LIMITATIONS. Side of Hot Air Diffuser 24" 12" i,I ta 0 p w u'w. . \ 1/2"ProPEX Fitting 2" Front of Hot Air Diffuser 36" 18" 3 c a 5 0 =o d F 13.SPRINKLERS ARE NOT NECESSARILY CENTERED IN ROOMS DUE TO LIGHT FIXTURES OR OTHER CEILING /� - 3/4"ProPEX Fittingz MOUNTED OBSTRUCTIONS. Lead-FreeFlz[ 3" Hot Water Heater 6" 3' pUO�m Y�YOy.,-n0� O Concealed \ ru .ti . y 1"ProPEX Fitting 3 1/2° Furnace 6" 3" o •'e m "r'0 a 0 9 9 14. THE PLUMBING TIE IN CONNECTIONS ARE SCHEMATIC IN NATURE AND CAN BE INSTALLED OFF THE Sprinkler HeadJu \ Concealed Flat 50W-250W Light Fixture 6" 3" ".E>a 9a u m X-m w m j SPRINKLER LOOP ANYWHERE BETWEEN SPRINKLER TO SPRINKLER CONNECTION. Cover Plate 1 1/4"ProPEX Fitting 4 1/2" m v, e o_0 o h< a 250W-499W Light Fixture 12" 6�� y�I "3R Sooi>�az 8o 0 z 15. THIS SUGGESTED LAYOUT IS BASED UPON INFORMATION PROVIDED BY OTHERS. CHANGES IN \ ux,a FlS o 0 a o u F w CONSTRUCTION OR FIELD CONDITIONS MAY OCCUR WHICH MAY REQUIRE CHANGES TO THE LAYOUT. IT IS F w h r u a u u z o s'a EQ Exposed Installation Requirements. < THE RESPONSIBILITY OF THE INSTALLER TO NOTIFY UPONOR TECHNICAL SERVICES OF SUCH CHANGES. Uponor AquaPEX'"'tubing(white)and ProPEXTM EP Fittings and ProPEXt"" \ u' 16. NFPA 13D 8.2.5*OBSTRUCTIONS TO RESIDENTIAL SPRINKLERS Brass Fittings are approved for exposed installation where the following • 8.2.5.7* SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG AS conditions are met.(UL 1821 Approved) - THE CUMULATIVE DRY AREAS DO NOT EXCEED 15 FT.PER SPRINKLER. o • 8.2.5.8 SMALL AREAS CREATED BY ARCHITECTURAL FEATURES,SUCH AS PLANTER BOX WINDOWS,BAY Exposed Wood Joist Ceiling Assemblies. o ^ ry /r...,),r: Eli m I here by certify that this plan,specification, WINDOWS,AND SIMILAR FEATURES,SHALL BE EVALUATED AS FOLLOWS: 1. Joists are of dimensional lumber,engineered wood or wood I-joist. "I u I or report was prepared by me or under my (1)WHERE NO ADDITIONAL FLOOR AREA IS CREATED BY THE ARCHITECTURAL FEATURE,NO 2. Joist are of depths from 6-16 inches(152-204 mm). direct supervision and that I am NICET ADDITIONAL SPRINKLER PROTECTION IS REQUIRED. 3. Joist are of spacing from 12-24 inches(305-610 mm)on center. Certified. (2)WHERE ADDITIONAL FLOOR AREA IS CREATED BY AN ARCHITECTURAL FEATURE,NO ADDITIONAL 4. Joists can be exposed after installation. ❑ SPRINKLER PROTECTION IS REQUIRED,PROVIDED ALL OF THE FOLLOWING CONDITIONS ARE MET; 5. Metal pipe hangers spaced at maximum 24 inches(610 mm)on center \ i (a)THE FLOOR AREA SHALL NOT EXCEED 18 FT'(1.7 M2) are used. 1.55" 1.66" (b)THE FLOOR AREA SHALL NOT BE GREATER THAN 24 INCHES IN DEPTH AT THE DEEPEST POINT OF 6. Listed residential automatic sprinklers of maximum activation Tim W McDonald Date: THE ARCHITECTURAL FEATURE TO THE PLANE OF THE PRIMARY WALL WHERE MEASURED temperature rating of 155.F(68.C). +i"-i" Hanger 1" Hanger NICET Certification No.150393 ALONG THE FINISHED FLOOR. Water-Based Systems Layout-Level III (c)THE FLOOR SHALL NOT BE GREATER THAN 9FT IN LENGTH WHERE MEASURED ALONG THE2022 PLANE OF THE PRIMARY WALL. Tubing Support Spacing: Certification Expires:June , Metal Tubing Support. (d)MEASURED FROM THE DEEPEST POINT OF THE ARCHITECTURAL FEATURE TO THE SPRINKLER SHALL NOT EXCEED THE MAXIMUM LISTED SPACING OF THE SPRINKLER. 1. Metal tubing supports designed for plastic tubing shall be used. Enough to(Anchor guPEX Tubing Securely Enough to Alow the Tubing to Expand and Contract)port the Tubing,Yet Relaxed 2. Do not use supports that will damage the tubing.Inspect metal (3)THE HYDRAULIC DESIGN SHALL NOT BE REQUIRED TO CONSIDER THE AREA CREATED BY THE supports for sharp edges. 1. Along Horizontal Runs,Install Supports Every 32",If Horizontal Runs are 1 1 1 ARCHITECTURAL FEATURE. 3. Do not rigidly anchor Uponor AquaPEXT°'tubing with supports.Allow Continuously Supported,Place Tubing Supports at Six-Foot Intervals. LJ..1 17. NFPA 13D 8.3 LOCATION OF SPRINKLERS. enough tubing for freedom of movement to expand and contract. 2. Along Vertical Runs,Install Supports Every Four to Five Feet,at Each ( l • 8.3.1 SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT WHERE OMISSION IS PERMITTED BY 8.3.2 Floor and at a Mid-story Guide. v u THROUGH 8.3.8. • 8.3.2 SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 FT'(5.1 Mz)AND LESS In-line Flow Test Ce E f m' • 8.3.3 SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,LINEN CLOSETS,AND PANTRIES THAT The In-line Flow Test can be constructed on site. It performs a flow test to a O MEET ALL OF THE FOLLOWING CONDITIONS: High Upstream Pressure ensure proper system operation and flow(see Figure F001-8). ,E D N o ,9;-, (1)THE AREA OF THE SPACE DOES NOT EXCEED 24 FT°(2.2 M'). If the upstream pressure exceeds 80 psi a pressure reducing valve may <z e 11 (2)THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLEneed to be installed. Some jurisdictions may require a pressure reducing 0<m,ix ao\ MATERIALS AS DEFINED IN NFPA 220,STANDARD ON TYPES OF BUILDING CONSTRUCTION. valve regardless of upstream pressure. Uponor AquaPEX W a L9 uus ry .. • 8.3.4* SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES,OPEN ATTACHED PORCHES,CARPORTS,AND Tubing SIMILAR STRUCTURES ,°Ci, • 8.3.5 SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE,PENTHOUSE H j EQUIPMENT ROOMS,ELEVATOR MACHINE ROOMS,CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND z ui CONTAINING ONLY DWELLING UNIT VENTILATION EQUIPMENT,FLOOR/CEILING SPACES,ELEVATOR SHAFTS, �'7 /��f� / / , - z_ CRAWL SPACES,AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVINGi / , f � • III �.1 0- ;./,"' W,', /,'(//j&/, Q > HSO PURPOSES. ///,2 // i� 7 z G"-V a m • 8.3.5.1 SUCH SPACES THAT CONTAIN FUEL-FIRED EQUIPMENT SHALL ALSO COMPLY WITH 8.3.5.1.1 OR / W LL Q i F S i-I1 V 8.3.5.1.2. - - d- O O o J i w • 8.3.5.1.1 WHERE THE FUEL-FIRED EQUIPMENT IS ABOVE ALL OF THE OCCUPIED AREAS OF THE DWELLING • - Male Threaded Coupling / ProPEX Fire u u u a a m 0 0 UNIT,NO SPRINKLER PROTECTION SHALL BE REQUIRED IN THE CONCEALED SPACE. Q Sprinkler Adapter a/ m • 8.3.5.1.2 WHERE FUEL-FIRED EQUIPMENT IS BELOW OR ON THE SAME LEVEL AS OCCUPIED AREAS OF THE �i N w DWELLING UNIT,AT I FART ONE QUICKRESPONSE INTERMEDIATE TEMPERATURE SPRINKLER SHALL BE N 1"Ball Valve LLI a INSTALLED ABOVE THE EQUIPMENT OR AT THE WALL SEPARATING THE SPACE WITH THE FUEL-FIRED -To Hot Water Heater Male Threaded Coupling EQUIPMENT FROM THE OCCUPIED SPACE. i Female Threaded LT- ENTRANCES/EXITS ,/ • 8.3.6 SPRINKLERS SHALL NOT BE REQUIRED IN UNHEATED ENCLOSURES AT THE BUILDING AT '�i ©rl� ! Tee with Water O o g AS LONG AS THE DWELLING UNIT HAS ANOTHER ENTRANCE/EXIT. • 8.3.7 SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING n Pressure Gauge 0 o 0 CONDITIONS: 2 y C)� Pressure Gauge Sprinkler Orifice (Optional) o O O LL (1)THE TOTAL VOLUME OF ALL UNPROTECTED CEILING POCKETS IN A COMPARTMENT DOES NOT EXCEED w `a } Q f z m a 100 FT.(2.83 Ma). w Flow Test 0 m g w ti c (2)THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS •N . To ensure the system provides enough water for proper fire sprinkler O 0 n m .,°.' AT THE LOWER CEILING ELEVATION. rn .. (3)*THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET EXCLUDING DECORATIVE performance,you should conduct a flow verification test. W _ Uponor Warning Signs Y r TREATMENTS IS NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIAL. "` /1 1CD 1 :z w (4)SKYLIGHTS NOT EXCEEDING 32 FT.(2.97 Mz)SHALL BE PERMITTED TO HAVE A PLASTIC COVER. _ n Note: The NFPA 13D Installation Standard does not require flow , V y m • 8.3.8 SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR CLOSETS verification. /l 1_''J► V) IL.' Z6Sgz (REGARDLESS OF SIZE)LOCATED ON EXTERIOR BALCONIES,EXTERIOR BREEZEWAYS/CORRIDORS,OR - i , Pressure Reducing Before performing a flow verification test,confirm the water pressures by v �// •Lr w ACCESSED FROM OUTDOORS WHERE THE CLOSET DOES NOT HAVE DOORS OR UNPROTECTED Z 1 O)} Valve contacting the Water and Sewer Department of your local city. Ensure the d o u�IS in z PENETRATIONS DIRECTLY INTO THE DWELLING UNIT. _ � available water pressure matches the pressure used in the system design. • 8.3.9 SPRINKLERS SHALL BE INSTALLED IN ANY CLOSET USED FOR HEATING AND/OR AIR-CONDITIONING a ' 11 SHEET DESCRIPTION EQUIPMENT,WASHERS AND/OR DRYERS,OR WATER HEATERS EXCEPT AS ALLOWED BY 8.3.8. Note: The sprinkler plan indicates the most hydraulically remote sprinkler '` O I Main Fire Sprinkler (or pair of sprinklers). For test requirements on other sprinklers,consult GENERAL NOTES&DETAILS 18. INSULATION GUIDE LINES PER NFPA I3D. a - Shut-off Valve your local code. • 9.1.1*WET PIPE SYSTEMS. A WET PIPE SYSTEM SHALL BE PERMITTED TO BE TO BE USED WHERE ALL PIPING IS INSTALLED IN AREAS NOT SUBJECT TO FREEZING,INCLUDING AREAS PROPERLY INSULATED TO Note: It is a good idea to notify the fire inspector at least 24 hours prior to MAINTAIN 40.F. •• A.9.1.1 IN AREAS SUBJECT TO FREEZING,CARE SHOULD BE TAKEN IN UNHEATED ATTIC SPACES TO performing a flow verification test. This may up the inspection test process and eliminate the need to repeat the test for the inspector. SHEET NUMBER COVER SPRINKLER PIPING COMPLETELY WITH INSULATION. INSTALLATION SHOULD FOLLOW THE Note: See"AquaSAFE Flow Test Instruction Sheet"(Provided in GUIDELINES OF THE INSULATION MANUFACTURER.FIGURE A.9.1.1(A)THROUGH FIGURE A.9.1.1(F) SHOW SEVERAL METHODS THAT CAN BE CONSIDERED. THESE ARE FOR ILLUSTRATIVE PURPOSES ONLY. __• Contractors Documents package or online at www.Uormingponor ro.com)for CONSULTATION WITH THE GENERAL CONTRACTOR AND/OR OWNER IS.RECOMMENDED TO ENSURE more information on Flow Test Setup,Assembly,Performing the Test and PROPER METHODS AND MATERIALS ARE USED TO MAKE SURE 40.F WILL BE MAINTAINED. Troubleshooting. If there are any questions please contact Uponor. 80 psi © UPONOR - CONFIDENTIAL FO 0 1 PRV Set Pressure