Specifications
fY rYv. OFFICE COPY fes2o2/-OD092- lECEIVED FIRE ALARM SYSTEM AUe 2 ZOZ1 SUBMITTAL GUIDE 1IYOFTIGARD EILDING DIVISION Kaiser Permanente Tigard Dental Office 7105 SW Hampton Road Portland, OR 97217 MARCHE l WET W N F{s EaE1N I Prepared By: PERFORMANCE SYSTEMS INTEGRATION 7324 SW Durham Road Portland, Oregon 97224 info@psintegrated.com. (503) 641-2222 Phone (503) 641-1464 Fax 7/15/2021 PART ID MANUFACTURER DESCRIPTION I01000GD EST FACP RLCD-C EST ANNUNCIATOR SIGA-278 EST PULL STATION SIGA-CRH EST HIGH OUTPUT CONTROL RELAY MODULE SIGA-CT2 EST DUAL INPUT MODULE SIGA-OSHD EST SMOKE AND HEAT DETECTOR SIGA-SB4 EST BASE SIGA-SD EST SUPERDUCT SMOKE DETECTOR SD-TRK EST REMOTE TEST STATION GCAVWF EST CEILING HORN-STROBE GCVWF EST CEILING STROBE GP10 EST SIDE PLATE ROOM WIRING PLATE INDIVIDUAL DURA12-12F2 DURACELL 12V,12AH SLA BATTERY SAE10 EST DOCUMENT CABINET cEb EDWARDS Catalog P Small Building Fire alarm Solutions WAR DS United Technologies LIFE SAFETY 6. INCIDENT MANAGEMENT r� f w ara Intelligent Fire . �: $ r•AlarmSystems i064 101000 FDNY I y w i COA 6227 AparuiMw O` )WARMS CO 7165-1657: ° 5OWARO8 0244 S3000 Overview Features EDWARDS brand intelligent life safety systems offer the power • Auto-programming speeds installation time of high-end intelligent processing in configurations that deliver • Supports Signature Series intelligent modules and detectors uncomplicated solutions for small to mid-sized applications.With intelligent detection,electronic addressing, automatic device • Combines the Signature intelligent releasing module with mapping,optional Ethernet®connectivity,and a full line of easily- Signature multisensor detectors for reliable fire suppression configured option cards and modules,these flexible systems offer • Form C contacts for alarm and trouble, Form A for supervisory versatility that benefits building owners and contractors alike. • Electronic addressing with automatic device mapping The 1064 provides one Class A or Class B intelligent device loop • Optional Ethernet port for diagnostics,programming and a that supports up to 64 device addresses, and two Class B Notifi- variety of system reports cation Appliance Circuits(NACs). Optional Class A device wiring is available with the use of a module. • Two programmable switches with LEDs and custom labeling • The i01000 provides one Class A or Class B intelligent device Supports Genesis horn silence over two wires, and UL loop that supports up to 250 device addresses. Loop controller 1971-compliant strobe synchronization modules may be added in combination to expand total system • Class B or Class A wiring capacity in 250-point increments to up to 1,000 device addresses. • Ground fault detection by module The iO1000 panel includes four NACs that may be wired for either Class A or Class B operation. • Supports up to eight serial annunciators, (LCD, LED-only, and graphic interface) The RZI16-2 module adds even more capacity to iO installations • Can use existing wiring for most retrofit applications by adding up to 16 conventional device circuits and two additional notification appliance circuits.This makes them an ideal retrofit • Upload/download remotely or locally solution that can accommodate new intelligent detectors,as well • Two-level maintenance alert reporting as existing conventional devices. • Pre-alarm and alarm verification by point iO Series supports a wide range of high-end features, including: • Adjustable detector sensitivity • Signature Series intelligent modules, detectors, and bases • 4 x 20 character backlit LCD display • R Series remote annunciators • Optional earthquake hardening: seismic Importance Factor 1.5 • SIGA-REL Releasing Modules • Standalone operation • Fully integrated CO detection using Signature Series detec- tors with or without audible signaling • Alarm ON command manually activates alarm condition Page 1 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.3 Application EDWARDS i0 Series life safety systems are powerful intelligent solu- Perfect for retrofits tions for small to mid-sized buildings.Advanced intelligent technol- EDWARDS iO Series control panels are particularly well-suited to ogy delivers the benefits of flexible system installation,while clean retrofit applications.All connections are made over standard wiring and easy-to-operate user interfaces make panel operation and -no shielded cable required.This means that in most situations system maintenance quick and intuitive. existing wiring can be used to upgrade a legacy control panel to i0 technology without the expense or disruption of rewiring the en- The smart choice tire building. i0 control panels also support the ingenious RZI16-2 Signature Series electronic addressing eliminates the tedium of Zone Module,which adds up to 16 conventional circuits and two setting dipswitches,and automatic device mapping ensures that NACs.This combination easily accommodates new intelligent each device resides on the system at its correct location. Mean- detection alongside existing conventional circuits, making it an while, innovative programming allows the designer to customize superior solution in the retrofit market. the system to precisely suit the needs of the building owner. Scalable IP and Cellular Communications Reliability you can count on Several popular third-party IP/Cellular communicators have been The inherent fault-tolerant characteristics of Analog/Addressable tested with the i0 control panels and are compatibility listed to Technology boosts the reliability of EDWARDS fire alarm systems. UL864.The IP/Cellular communicators meet NFPA72 2013 edition When combined with i0 Series smoke and heat detectors,these requirements for sole or secondary transmission paths. Using IP/ systems deliver a level of dependability not previously available for Cellular communicators can reduce the cost of ownership by small to mid-sized applications.All EDWARDS systems are built to eliminating POTS lines. Please see the iO control panel compat- exacting reliability benchmarks. ibility documentation part number 3102353-EN for a full list of compatible communicators. Clear-cut remote annunciation Remote annunciation is a strong suit of the iO Series fire alarm Signals with a difference systems. Up to eight annunciators can be installed on a single iO system NACs are configurable to fully support the advanced system. Compatible annunciators include a range of LED and LCD signaling technology of EDWARDS Genesis and Enhanced Integ- models that provide zone or point annunciation,as well as com- rity notification appliances.These devices offer precision synchro- mon control capabilities. i0 control panels also supports graphic nization of strobes to UL 1971 standards. For Genesis devices, annunciation with optional RA Graphic Annunciator interface mod- enabling this feature allows horns to be silenced while strobes on ules. Each interface provides common control and 32 LEDs. the same two-wire circuit continue to flash until the panel is reset. Flexibility built right in A complete line of accessories Two fully-programmable front panel switch/LED combinations provide iO Series life safety systems are supported by a complete line of an added measure of flexibility.Their slide-in labels take the mystery analog/addressable detectors, modules and related equipment. out of custom applications,and present a clean finished appearance. Consult the Ordering Information section for details. I i 1 Programming and remote diagnostics Dimensions EDWARDS i0 Series life safety systems are simple to set up,yet "' O1 (3) (4) offer advanced programming features that put these small building I'-°e''I D3 4-°T panels into a class of their own.The auto programming feature 0 00 '-'0 '0 T'--� quickly gets the panel operational using factory default settings. I` I :0 0 Basic zone and point settings can be programmed through the • 0 0 0 front panel interface,so the system is up and running in no time. I _ I 0 0 O For more advanced system configuration and correlation groups • p1 , 04 • O° • programming,i0 Series systems interface to a PC running com- _ o • O 0 0 patible i0-CU software.This option offers full system configuration in the familiar Windows®operating environment.Connection is made to a laptop through the panel's optional RS-232 communi- • cations port,which can also be used to connect a system printer. • Among the many innovative features of i0 Series control panelsDs 1 is the optional network card.This module provides a standard (1)Surface Mounting Holes (3)Backbox with Door Attached 10/100 Base T Ethernet®network connection that permits access (2)Semi-flush mounting Holes (4)Backbox with door and trim kit attached. to the control panel from any remote location with the correct communications protocols.The connection can be used to Panel dimensions,in(cm) download to the panel from the iO-CU,or upload and view system Model D1* D2 D3 D4 D5' D6 D7 08 D9 reports using the i0-CU. 101000 28.0 3.85 9.0 22.0 15.75 10.25 4.4 28.2 2.7 (71.1) (9.8) (22.8) (55.8) (40.0) (26.0) (11.1) (71.6) (6.8) Available system reports include:Correlation groups, Device de- i064 21.5 3.85 7.5 15.5 14.25 10.25 4.5 21.7 2.7 (54.6) (9.8) (19.0) (39.4) (36.2) (26.0) (11.4) (55.1) (6.8) tails, Device maintenance, History,Internal status,System configu Add 1-1/2 in.(3.81 cm)to D1 and D5 dimensions for trim b't.The trim kit ration,System status,Walk test, Dialer,and CO runtime. provides 0.75 inches(1.9 cm)of trim to the top,bottom,and sides of the backbox. Page2of8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.3 System Layout iol000 Any combination of two single-or dual Signature loop modules a ----A. r " ' —, r ;, _r 1 I I1 ¢I,A ": b1izf �1ry ¢� :',°- . tl,,�r l 4 yyia, Standard Loop:250 points(one expansion slot) i0-SDC2 Expander,Loop 1 of 2:250 points Up to 125 sensors and 125 modules per loop (one expansion slot) r. ,, a . P4 ',e ___d ., _ ,�_L 10-SDC1 Expander Loop:250 points(one expansion slot) 10-SDC2 Expander,Loop 2 of 2:250 points Up to 20,000 feet of wiring per loop I FIRE FIRE FIRE FIRElir _ FIRE FIRE FIRE FIRE SIRE- - -• Iv Four Class B or two optional Class A NACs i t Four Class B or two optional Class A NACs Optional 10 A or 6.5 A Booster zs, Ethernet(SA ETH) _ __ , s , Up toeig ht remote annunciators DACT/Dialer(SA-DACT) , RS-232(SA-232) _ Sixteen Conventional IDCs, Relays:Two Form C,one Form A , two additional NACs with RZI16-2 module Each iO1000 panel has room for up to two Signature loop control- ler modules in any combination of single or dual 250-device loops. i01000 loops support 125 detectors and 125 modules. Panel Layout 4 3 -® ® 8 8® 5 • Li ■._a i064 2 K , --'t-11. `6 7 f r. M� �• vt it- l It CY r�yr- Loop supports up to 64 intelligent devices of any type. s !- 10 Up to 20,000 feet of wiring. ••_ -- li r r '• i--11 1 12 O m 0 FIRE FIRE FIRE FIRE 1._. 13Two Class B or two optional Class A NACsr I Optional 10 A or 6.5 A Booster Power Supply ° 7. ' 1 Transformer Up to eight rerno earinunciators 2 Main AC wiring block&fuse holder 3 RS-232 card connector(J3) Ethernet(SA-ETH) . - 4 Dialer card connection(J8) 5 Ethernet card connector(J1) DACT/Dialer(SA-DACT) i 6 Main circuit board RS-232(SA-232) 7 Panel backbox enclosure Relays:Two Form C,one Form A 8 Operator interface 9 SLC card connector(J7) 10 Class A card connector(J2) Each i064 panel ships with one Signature loop controller that sup- 11 Tie wrap mounts 12 LED expander connector(J6) ports 64 devices of any type.This panel's device capacity cannot 13 Standby batteries be expanded. Page 3 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.3 Wiring & Configuration Signature device loop Auxiliary&smoke power outputs(TB3) The system provides one Signature device loop circuit with a total The control panel provides two auxiliary power TB3 capacity of 125 detectors and 125 module addresses.The loop outputs that can be used for powering ancillary 0--a- circuit is supervised for opens, shorts,and grounds. equipment such as remote annunciators and two (1) wire smoke detectors. Aux 2 can be softwareCircuit ( ) NC specifications i01000 i064 selected to operate continuously.The circuit is 0 1 Device loops One Class B or A One Class B or A loop, supervised for shorts and grounds. loop,supporting 125 supporting 64 devices of Circuit specifications (2) 0_a'NO detectors and 125 any kind. Circuit voltage 21.9 to 28.3 V modules.Expandable to range NC four loops. Resettable circuit 24 VDC nominal at 500 mA (3) Communication Maximum 20 V peak-to-peak (Aux power 2) NO 0 line voltage Continuous circuit 24 VDC nominal at 500 mA. _ Circuit current 0.5 A max (Aux power 1) Use this circuit for powering 0 Circuit 66f1 total,0.5 VF,max two-wire smoke detectors. impedance (4) Isolators 64 maximum Note:Any current above 0.5 amp connected to both Aux 1 and 2 will reduce the total available NAC power by that to Signal Supported on a system-wide basis(all device loops) amount. Synchronization when using a SIGA-CC1S or SIGA-MCC1 S module (1)Trouble and Genesis or Enhanced Integrity notification ap Alarm trouble,andsupervisoryT63 pliances. relay( ) (2)Supervisory The trouble relay is normally-open, held closed, (3)Alarm Class wiring Class A wiring and opens on any trouble event or when the panel is de-energized.The supervisory relay is (4)Smoke/Aux SLC A ,m Data Line SLC A , normally open,and closes on any supervisory CI I event.The alarm relay changes over on any SLC B I�(e SLC B + A. alarm event. Loop Loop Loop Loop Loop card device Loop card Data Line device device Relay specifications Alarm i Trouble Supervisory Type Form C Form A Notification appliance circuits(TB2) Voltage 24 VDC at 1 A resistive 24 VDC at 1 A resistive 101000 control panels come equipped with four notification ap- Relay circuits can only be connected to power-limited sources. pliance circuits. i064 control panels come with two NACs. Each circuit can be individually configured for continuous,temporal, synchronized,and coded output. Annunciator loop(TB4) Specifications i01000 i064 The control panel provides a connection for up to eight serially Circuit Type 4 Class B or 2 Class A 2 Class B or 2 Class A driven and supervised remote annunciators. with SA-CLA module Voltage 24 VFWR Circuit specifications Current 6.0 A total,2.5 A max. 3.75 A total,2.5 A max. Device loops Class B(Style Y)or Class A(Style Z) per circuit at 120/230 per circuit at 120/230 Circuit voltage 2.55 V VAC 60 Hz. VAC 60 Hz. Circuit current 30 mA max 5.0 A total,2.5 A max. 3.0 A total,2.5 A max. Circuit Up to 8 annunciators or 4000 feet per circuit at 230 VAC per circuit at 230 VAC impedance 50 Hz. 50 Hz. Impedance 26 fl total,0.35 OF max Class B Class A EOLR 15 K fl,1/2 V1l Channel 1 Channel 2 Channel 1 Channel 2 Synchronization Supported system-wide + — + — + — + — Is) ® ® ® TB4 ® ® (s) ® TB4 Class 8 wiring Class A wiring Annunciator Annunciator NAC1 NAC1- �CH1(+)IN e CHI(+)IN + + NAC1+ / NAC1+ a a - - (5)CH1(-)IN - - ®CH1(-)IN 0 NAC2- EOLR 0 NAC2- + + O NAC2+ 0 NAC2+ a• a TB2 TB2 ®CH2(+)IN IS CH2(+)IN O NAC3- ®CH2(-)IN1:S)CH2(-)IN O NAC3+ 0-+ NA EOLR NAC4+ - - 0 + TB6 TB6 Marking indicates output signal polarity when the circuit is active.Polarity reverses when the circuit is not active.Wire notification appliances accordingly Notification appliance polarity shown in active state. Page 4 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.3 Option Cards EDWARDS iO Series panels are supported by a complete line RZI16-2 Remote Zone Interface Module of modules and related equipment that enhance performance _ and extend system capabilities.Option cards plug directly into '_ the control panel main circuit board or are connected to it with a _ ar+.) ribbon cable.After installation,terminals remain accessible.The Iv ^� cabinet provides ample room for wire routing,keeping wiring neat -_ I I 57"s at all times. - ' _111_ -` Single and Dual Loop Controller Cards The RZI16-2 Addressable Remote Zone Interface Module is an The iO-SDC1 is a single loop controller card that can be used with addressable device that provides connections for sixteen Class B the iO64 as a replacement for the standard 64-point loop,or with Initiating Device Circuits and two Class B Supervised Output the i01000 as a 250-point expansion module. Circuits.The inputs and outputs can be configured individually for The iO-SDC2 is a 500-point dual loop controller card for the several device types. iO1000 that provides two SLC circuits,each with 125 detector It requires 18 consecutive addresses on the Signaling Line Circuit addresses and 125 module addresses. (SLC).Addresses are assigned electronically.There are no address switches to set. Specifications iO-SDC1 iO-SDC2 Device Addresses iO1000:one loop,250 iO1000:two loops, The RZI16-2 incorporates two 8-segment DIP switches that are device addresses 500 device addresses used to select the Alarm or Supervisory default device type for i064:64 addresses each of the 16 IDC circuits.The module also includes one 4-seg- Wiring Class B or Class A ment DIP switch used to select the default Relay or NAC output Operating Voltage 24 VDC device type. Device types other than the default are accomplished Operating Current Standby:55 mA Standby:45 mA through programming. (fully loaded loop) Alarm:80 mA Alarm:70 mA Note:These ratings do not include the use of two-wire smoke modules. RZI16-2 Specifications Communication Line Max.20.6 V peak-to-peak Voltage 24V/Aux nominal: 24 VDC Voltage Terminal Rating 12 to 18 AWG(0.75 to 2.5 mm2) Supervisory current: 250 mA at 24 VDC nominal Alarm Current 1000 mA Circuit Current 0.5 A max. 24V/Aux minimum: 18.4 VDC Max total loop 66 fl 24V/Aux maximum: 26.4 VDC resistance NAC1,NAC2 nominal: 24 VDC Max total loop 0.5 pF Current capacitance Standby current Isolators 64 isolators maximum per loop(total both for 4.7 k EOL(U.S.) 4.8 mA/circuit isolator bases and modules) Standby current for Ground Fault 0 to 5 k0 3.9 k EOL(Canada) 5.7 mA/circuit Impedance Alarm current Operating 32 to 120°F(0 to 49°C) at nominal voltage 31.1 mA/circuit Environment 0 to 93%noncondensing at 90°F(32°C) Relay outputs Quantity 2 Type Rating(pilot duty) Programmable 24 VDC at 2.5 A Input circuit wiring 25 0 per wire SA-ETH Ethernet Interface Card resistance SA-ETH wiring The SA-ETH card provides a Initiating device circuits r.....8 connect ern k standard 10/100 Base T Ether- Quantity 16 Network cable .r net network connection for EOL resistor 4.7 kr)(U.S.);3.9 kG Canada Vconnecting to an intranet,a local Zone voltage 22.78 V for 4.71(0(U.S.) network,or the Internet.The 22.08 V for 3.9 k!Z(Canada) 1 Alarm current 31.1 mA/channel at nominal voltage 0 ,,,,,,,,,,,°"i : card can be used to download Alarm impedance range <680 0 ,gE configuration programming from Trouble impedance range >5.55 ko ID iO-CU to the panel. Supervised output circuits DO The Ethernet card is installed on EOL resistor 15 kf� t ®_ Quantity 2 ®- the plastic assembly and con- Short circuit detection <2.6 kfl nects to the main circuit board Open circuit detection >61.9 kf) Ethernet card via a ribbon cable. Contact ratings 24 VDC at 2.5 A(5 A for two NACs) SA-ETH specifications Compatible cabinets MFC(A),iO1000,APS Ethernet 10/100 Base T Operating environment Temperature 32 to 120°F(0 to 49°C) Humidity 0 to 93%RH,noncondensing at 90°F (32°C) Page 5 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.3 ' SA-DACT Dialer SA-232 RS-232 interface The SA-DACT provides communications between the control The SA-232 card provides an RS-232 in- SA-232 wiring panel and the central station over a telephone line system. It terface with iO panels. It can be used for GND(black wire) TXD(white wire) transmits system status changes(events)to a compatible digital connecting a printer to the control panel RXD(red wire) alarm communicator receiver over the public switched telephone to print system events.The card also network.The dialer is capable of single,dual,or split reporting can be used for connecting a computer '�v-GGG I I of events to two different account and telephone numbers.The to download a configuration program 0 r modem feature of the SA-DACT can also be used for uploading from the i0-CU to the control panel. 0 El I and downloading panel configuration, history,and current status The RS-232 card is installed on the plas- to a PC running the iO CU. tic assembly and connects to the main circuit board via a ribbon SA-DACT Phone line 2 cable. wiring To wall Phone line 1 phone jack SA-232 specifications Phone cables Operating voltage Standard EIA-232 (supplied) RJ311jacks Terminal rating 12 to18 AWG(0.75 to 2.5 sq mm) The dialer phone lines connect to Operating environment connectors on the dialer's main Temperature 32 to 120°F(0 to 49°C) ® ® Humidity 0 to 93%RH,noncondensing at 90°F(32°C) °,°Q o circuit board.Phone line 1 connects n°00 to connector J4 and phone line 2 connects to connector J1. „=° SA-CLA Class A Module(i064 only) °❑❑��p .:° 0 The SA-CLA card provides Class A capability for NAC wiring. oo❑❑�uo° ° o Its terminal block provides the wiring connection for NAC return I� al== Eo wiring.The card is required for annunciator Class A wiring even Et;" though this wiring does not return to the SA-CLA card.The SA- The SA-DACT queues mes- CLA is compatible with iO64 control panels only. i01000 panels sages and transmits them based on priority(alarm,supervisory, are Class A Ready.The SA-CLA is installed directly to the control trouble,and monitor).Activations are transmitted before restora- panel circuit board using its plastic standoffs and plug connection. tions. SA-CLA specifications The SA-DACT is installed on the plastic assembly and connects to Operating voltage 24 VFWR the main circuit board via a ribbon cable. Operating current 3.75 A FWR total at 120/230 VAC 60 Hz SA-DACT specifications 3.0 A FWR total at 230 VAC 50 Hz 2.5A max per circuit Phone line type One or two loop-start lines on a public, switched network Circuit impedance 26ohms,0.35uF Terminal rating 12 to18 AWG(0.75 to 2.5 sq mm) Phone line connector RJ-31/38X(C31/38X) _ Operating environment Communication formats Contact ID(SIA DC-05) Temperature 32 to 120°F(0 to 49°C) Operating environment Humidity 0 to 93%RH,noncondensing at 90°F Temperature 32 to 120°F(0 to 49°C) (32°C) Humidity 0 to 93%RH,noncondensing at 90°F (32°C) Compatible DACRs D16L-iO LED Display Expander(iO1000 only) Receiver Models Formats The D16L-iO LED Display Expanders provide LED annunciation for Ademco 685 Contact ID up to 16 zones. It provides two LEDs for each zone.Two D16L-iO FBI! CP220 Contact ID LED display expanders can be installed in each iO1000 panel. Osborne-Hoffman OH 2000 Contact ID Bosch D6600 Contact ID (3) (4) Silent Knight 9800 Contact ID (1) � LIRL"it (1) Zone 17 (1)LED 1 Sur-Gard SG-MLR1,MLR2 Contact ID (2) A (Z)� , (2)LED 2 M= (3)LED Expander 1 KII1• 1 A_ (4)LED Expander 2 M. Mom (5)Alarm/non-alarm A_ INMENand trouble zone LEDs ommoui mom ommi um= 011111111111 01.11111111 OtCrix] !��� (5) • , on - Zone 32 Page6of8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.3 Specifications 1064 iOl000 Device loops 1 loop Class B or Class A(Styles 4,6,7)supporting up to 1 loop,expandable to 4,Class A or B(Styles 4,6,7), 64 device addresses(any combination of detectors and each loop supporting up to 250 device addresses(125 modules) detectors and 125 modules max.).Addresses 1 to 125 are for detectors and addresses 126 to 250 are for modules Maximum T-taps:63 (each device can be on its own branch) Maximum T-taps/loop:124 Notification appliance 2 Class B(Style Y),Class A(Style Z)optional 4 Class B(Style Y)or 2 Class A(Style Z) circuits 3.75 A FWR total at 120/230 VAC 60 Hz 6.0 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 5.0 A FWR total at 230 VAC 50 Hz 2.5 A FWR each max.per circuit 2.5 A FWR each max.per circuit Primary power 120 VAC,60 Hz,1.3 A max. 120 VAC,60 Hz,2.0 A max. 230 VAC,50-60 Hz,0.62 A max. 230 VAC,50-60 Hz,0.97 A max. Base panel current standby 155 mA 172 mA Base panel current alarm 204 mA 267 mA " Input zones 16 max. 32 max. Remote annunciator 8 drops max.,RS-485 Class B,Class A is optional 8 drops max.,RS-485 Class A or B Data line length:4,000 ft.(1,219 m) Data line length:4,000 ft.(1,219 m) Operating voltage 24 VDC panel Auxiliary power output Aux power 1:500 mA,24 VDC circuit Aux power 2:500 mA,24 VDC(1 A possible if you reduce total available NAC power by 500 mA) Output:28.3 to 21.9 VDC,special application Note:For a list of compatible devices,see the 1064 and 101000 Series Compatibility List(P/N 3102353-EN) Loop circuit Maximum loop resistance:66 f) Maximum loop capacitance:0.5 pF '= Communication line voltage:Maximum 20.6 V peak-to-peak ';- Operating current(fully loaded loop)Stand by:55 mA/45 mA Alarm:125 mA/115 mA(not including two-wire smoke modules) Circuit current:0.5 A max.Style 4,6,and 7 wiring Max.resistance between isolators:Limited only by overall wire run lengths 64 isolators maximum per loop(total both isolator bases and modules) p Batteries Type:Sealed lead acid Voltage:24 VDC Charging current:2.47 A max.Amp hour capacity:26 Ah Standby operation:24 hour or 60 hour Placement:Up to two 10 Ah batteries will fit in the iO64 control panel cabinet and two 18 Ah batteries will fit in the iO1000 control panel cabinet.If larger batteries are required,use an EDWARDS battery cabinet. SA-DACT dialer Phone line type:One or two loop-start lines on a public,switched network Phone line connector:RJ-31/38X(C31/38X) Communication formats:Contact ID(SIA DC-05) Operating current Standby/Alarm:41 mA Max.:100 mA FCC registration number:GESALO1 BSADACT Industry Canada Registration number:3944A-SADACT Ringer equivalence number:0.1 B t `? Ground fault impedance 0 to 5 kG Alarm contact Form C N.O.24 VDC at 1 A(resistive load) 1 Trouble contact Form C 24 VDC at 1 A(resistive load) Supervisory contact Form A N.O.24 VDC at 1 A(resistive load) Environmental Temperature:0 to 49°C(32 to 120°F)Relative humidity:0 to 93%noncondensing Terminal rating All terminals rated for 12 to 18 AWG(0.75 to 2.5 mm2) "fr Page7of8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.3 Ordering Information EDWARDS Part Description i01000 Fire Alarm Systems 101000G Four loop system with one 250-point loop installed.110v,gray door. LIFE SAFETY&INCIDENT MANAGEMENT I01000G-2 Four loop system with one 250-point loop installed.230v,gray door. 101000G-2-PG Four loop system with one 250-point loop installed.230v,gray door,Portuguese. Contact us... 101000G-2-SP Four loop system with one 250-point loop installed.230v,gray door,Spanish. Email: edwands f reofs.utc.com 101000G-CA Four loop system,one 250-point loop installed. 110v,gray door,LED strips,Canada. web: Eassalticeseca 101000GD Four loop system,one 250-point loop installed.110v,gray door,with dialer. 101000G-F Four loop system,one 250-point loop.110v,gray door,LED strips,French Canada. EDWARDS is a UTC brand. 101000G-PG Four loop system with one 250-point loop installed.110v,gray door,Portuguese. 1016 Corporate Park Drive101000G-SP Four loop system with one 250-point loop installed.110v,gray door,Spanish. Mebane,NC 27302 101000R Four loop system with one 250-point loop installed.110v,red door. 101000R-2 Four loop system with one 250-point loop installed.230v,red door. C 2017 United Technologies Corporation. 101000RD Four loop system,one 250-point loop installed.110v,red door,with dialer. All rights reserved. SA-TRIM2 101000 Flush mount trim,black. i064 Fire Alarm Systems I064G One loop system with one 64-point loop installed.110v,gray door. 1064G-2 One loop system with one 64-point loop installed.230v,gray door. 1064G-2-PG One loop system with one 64-point loop installed.230v,gray door,Portuguese. I064G-2-SP One loop system with one 64-point loop installed.230v,gray door,Spanish. 1064GD One loop system,one 64-point loop installed.110v,gray door,with dialer. I064GL One loop system,one 64-point loop installed.110v,gray door,English Canada. I064GL-F One loop system,one 64-point loop installed.110v,gray door,French Canada. I064G-PG One loop system with one 64-point loop installed. 110v,gray door,Portuguese. I064G-SP One loop system with one 64-point loop installed.110v,gray door,Spanish. 1064R One loop system with one 64-point loop installed.110v,red door. I064R-2 One loop system with one 64-point loop installed.230v,red door. 1064RD One loop system,one 64-point loop installed. 110v,red door,with dialer. SA-TRIM1 1064 Flush mount trim,black Option Cards i0-SDC1 Expansion module,one 250-device loop. i0-SDC2 Expansion module,two 250-device loops,500 devices total.For i01000 only. RZI16-2 Remote Zone Interface Module.16 Class B IDCs,2 Class B Output.Includes bracket. SA-DACT Dual Line Dialer/Modem,supports Contact ID,mounts in cabinet on base plate. SA-232 RS-232 Serial Port for connection to printers&computers,mounts in cabinet. SA-ETH Ethernet Port,Slave,mounts in cabinet on base plate. SA-CLA Class A adapter module.Provides Class A capacity on NACs.Mounts in cabinet on main board.1064 systems only. D16L-i0-2 LED Annunciator module,16 X 2-LED zones(4 programmable for sup). Mounts in cabinet to right of LCD display for zones 17-32.For i01000 only. D16L-i0-1 LED Annunciator module,16 X 2-LED zones(4 programmable for sup). Mounts in cabinet to left of LCD display for zones 1-16.For i01000 only. D8RY-i0-2 Canada only:LED Annunciator module,two LEDs per zone,16 zones(4 alarm only, 8 supervisory only,4 alarm or supervisory).Mounts in cabinet.For i01000 only. D8RY-i0-1 Canada only:LED Annunciator module,two LEDs per zone, 16 zones(4 alarm only, 8 supervisory only,4 alarm or supervisory).Mounts in cabinet.For i01000 only. Accessories CTM City Tie Module.2-gang.Connection to a local energy fire alarm box. MFC-A Multifunction Fire Cabinet,8"x 14°x 3.5"-red. SIGA-REL Releasing Module PT-1 S System Printer BC-1 Battery Cabinet.14.0"x 18.25"x 7.25".Holds two 12V24A batteries. BC-1 R Battery Cabinet-Red.14.0"x 18.25"x 7.25".Holds two 12V24A batteries. BC-1 EQ Seismic hardening Kit for i0 series panels.Includes battery hardening for BC-1 enclosure and components to harden panel internal components. Programming Tools 10-0U 10 Series configuration and diagnostics utility. 260097 RS232 cable,4 conductor,DB9 PC interface 0 Page 8of8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.3 urrr■1111111\ EST Gaticg►Annunciation EST Life Safety & Communications R-Series Remote © Q Ire Kann $ 0 C.wnd Faun Annunciators c�Trout* e�aea °Tr � RLCD, RLCD-C, RLED, RLED-C, 000 RLED24, GCI FDNY @ C0A 6020 7120-1657. C0A 6087 0254 S3424 Overview Features Edwards R-Series Annunciators are high-performance remote • LCD models feature large 4 x 20 character backlit LCD display annunciators that provide status indication and common controls • LED models provide 16 pairs of LEDs for zone annunciation for compatible fire alarm control panels,including iO-Series small analog fire alarm systems.This family of annunciators offers LCD • Available expander extends capability with 24 pairs of LEDs or LED annunciation. Models are available with and without com- • Up to two expanders may be wired to each annunciator mon controls. • Status LEDs and internal buzzer standard on all models There are three R-Series annunciator models, plus an LED-based expander. Up to two expanders can be connected to any annun- • Common controls available for LED and LCD display models ciator.The expander includes 24 pairs of LEDs that extend the • Available keyswitch for disabling common controls capabilities of any of the annunciators. • Standard 4-inch square electrical box mounting All annunciator models include status LEDs and an internal buzzer. • Two models have an LCD text display, and one has 16 pairs of Class B or Class A RS485 wiring standard LEDs for zone annunciation. LCD models feature a large back-lit, • One-,two-, and three-position enclosures available four by twenty character per line,super-twist liquid crystal display. • Graphic Annunciator interface, includes common control, indi- R-Series annunciators and expanders are mounted on a standard cators and 32 LEDS 4-inch square electrical box, using the included mounting ring. • No programing required, set the address and unit recieves all They can also be surface mounted in locking steel enclosures. information from panel Three different enclosures are available. A keyswitch and graphic annunciator interface is available for R-Series annunciator applications.The keyswitch enables or dis- ables common controls.The graphic annunicator interface cards supports 32 LEDs and 16 switches on the graphic panel display. Page 1 of 4 DATA s h a :: 85005-0128 Not to be used for installation purpose Issue 2 Application Annunciator Wiring R-Series annunciators communicate with the FACP on the RS-485 Annunciator, Class A data riser.This can be configured for Class A or Class B commu- nication.Annunciators do not provide ground fault isolation. FACP RS-485 q CH1(+)IN .CHi(+)IN These annunciators are stand-alone units that can be powered by CHI �. CH1(-)IN �II G CH7((:))INN -)IN the FACP or by an approved power supply. CH,_ '' � ',CH,(+)OUT 0 CHI(+)OUT CH2+ p CH1(-)OUT , 0 CHI(-)OUT V r, \ r,` CH2- �' e CH2(+)IN ' �i CH2(+)IN (//�` (//�" C CH2(-)IN .CH2(-)IN • "�• LISTED 24 VDC C CH2(+)OUT 0 CH2(+)OUT °o.�w $ o. .� °o rF y Io SMY SUPPLY 0 CH2(-)OUT ' 0 CH2(-)OUT u •,Wa. ,/ .�rrsun,m e a 0:,,4„`�° 24 VDC+,' i G 24V(+)IN ' 24V(+)IN ®®I� . _.. o Q•a•'v 24 VDC- 124V(-)IN 624V(-)IN '„"` o ®"`"�'�"� C 24V(+)OUT 0 24V(+)OUT . , 1 8 00 l,",� .,24V(-)OUT ' 024V(-)OUT V O 9 A C , rl 9 q \ — 1 r,GROUND I - , r GROUND DI RLCD-C (L RLED-C l/ \ / Annunciator, Class B • ° I a °°" ' °o o° FACP Annunciator Anondalor 0 0 0 0 RS-495 0 CHI(+)IN 0 CH1(+)IN ®DID® °o CHt+ 0 OCHI(-)IN - 0CHI(-)IN CH1- 0 0 CH1(+)OUT 0 CHI(+)OUT //�� CHI(-)OUT 0 CHI(-)OUT •(I ,g l� \ ° (I .4p ��o 0 CH2(+)IN 0 CH2(+)IN W H U 9 O CH2(-)IN O CH2(-)IN RI.CD RLED24 LISTED 24 VDC 0 CH2(+)OUT 0 CH2(+)OUT Features by RLCD RLCD-C RLED-C RLED24 SUPPLY O CH2(-)OUT O CH2(-)OUT model 24 VDC+0 024V(+)IN 024V(+)IN Reset ✓ ✓ 24 VDC-0- 0 24V(-)IN 0 24V(-)IN II 24V(+)OUT 0 24V(+)OUT Ack/Silence ✓ ✓ ✓ - �24V(-)OUT 0 24V(-)OUT Fire Alarm ✓ ✓ ✓ - 0 GROUND 0 GROUND Supervisory ✓ ✓ ✓ - _ Ground Fault V ✓ ✓ - Trouble ✓ ✓ ✓ - Controls Enabled ✓ ✓ ✓ - Expander Ack/Silence ✓ ✓ ✓ - Reset First Expander Second Expander Signal Silence ✓ v OUT IN OUT IN OUT v(-)o C v(-) v(-1 0- --0 V(-) V(-)0 Drill ✓ ✓ v(+)o ov(+) vO0- - --OV(.) v(+)0 Lamp Test ✓ ✓ ✓ - FC CF F0- - --OF F0 LCD Display ✓ ✓ - - E e of e0- - 0E E0 Zone Active LEDs - - 16* 24** D, o D D 0 - 0 D D 0 Zone Trouble LEDs 16 24 C o o C C 0 - 0 C C 0 ep oe B0- - '0e e0 `zones 13-16 maybe selected as Supervisory on 1064 A o 6 A A 0- 0 A A 0 '"zones 13-16 and 29-32 may be selected as Supervisory on 10500 Graphic Annunicator Interface The GC! Graphic Annunciator Driver is an interface card that connects the fire alarm control panel to the display panel of an Remote Keyswitch LED-based graphic annunciator. Annunciator LSRA-RK The annunciator card supports 32 LEDs and 16 switches on the niKEYSWITCH(-)ei— 0 TH1-1 pl KEYSWITCH(+)0— 0 T81-2 graphic panel display. It includes status LEDs and an internal a buzzer. The graphic interface is supplied with snap track mounting.It is Keyswitch Specifications 4�1 attached to a plastic mounting rail that requires two EIA panels. Maximum 5 Vdc \ �+ i voltage i --,.. The annunciator communicates with the FACP on the RS-485 Maximum 200 mA data riser.This can be configured for Class A or Class B commu- current I nication.The annunciator does not provide ground fault isolation. Mounting 2-1/2 in(64 mm) \1j ez It is a stand-alone unit that can be powered by the FACP or by an deep 1-gang box i i .w approved power supply. Termination Screw terminals t Maximum 12 AWG Graphic Annunciator Interface Specifications wire size (2.5 mm sq) Alarm current 146 mA at 24 Vdc(with 36 LEDs ON) Contact Normally open �! Standby current 36 mA at 24 Vdc(with no LEDs ON) configuration Maximum current 10 mA per LED Page 2 of 4 85005-0128 Not to be used Tor installation purpose.: Issue 2 4. Annunciator Connections Annunciator Mounting Annunciator ANNUNCIATOR RS-485 RISER Mounting slot DIP, • ilia_1‘ switch --] Remote keyswitch O RS-485 riser 8 terminals terminals — Expander cable ° Power terminals — terminals Communication "- _� O LEDs " ( 0 0 0o ° Expander 0 Mounting slot ® f i 1 a i, ilA E . Ili- EXPANDER CABLE Expander cable Expander cable v 11 terminals I1IiII ° Ire terminals ® O 0 0 DIP switch settings \Switch Description and values ° Si to S5 The annunciator network address(in binary). 0 Network The factory setting is for addrats 2. address Examples: 10000=1 01000=2 11000=3 00100=4 gmel S6 Network OFF=9600 baud(factory default setting) baud rate ON=38,400 baud (l F.,, �;� u� C �I S7 to S8 Not used MOUNTING RING EXPANDER ELECTRICAL BOX Annunciator Enclosures The RA Remote Annunciator Enclosures provide secure,surface - mounted protection for annunciators and extenders. Each con- sists of a back plate, hinged cover,and key lock. r . The enclosures are 16-gauge welded steel with a white, painted 6.0 in finish. Each enclosure includes a security lock and two keys.The 15.2 cm two-and three-position enclosures have wiring channels for cor- H rect routing of interconnections, The enclosures attach to a standard electrical box,and provide a 00 © mounting lip that takes the place of the integral mounting ring sup- plied with the annunciators and expanders. t0.9 in 2.3 cm X" °/ \o a\ / \ IIIII I I RA-ENC1 D I 9.5 in f 24.1 cm *I [..., 2.0 in X 9.8in 5.1cm 24.9 cm / Dimensions(H x W x D) IIIII ) RA-ENC1 6.3 x 9.8 x 2.0 in(16.0 x 24.9 x 5.1 cm) RA-ENC2 12.0 x 9.8 x 2.0 in(30.5 x 24.9 x 5.1 cm) RA-ENC3 17.7 x 9.8 x 2.0 in(45.0 x 24.9 x 5.1 cm) RA-ENC3 Alw pximy 2 cm) ac the 1 enclosureNote: lo,toa permit insertingatel andinches removing(50 thecle keyran,andeon openingbothsides theof door RA-ENC2 through 90 degrees. Page 3 of 4 L r.CA SHEET 85005-0128 Not to be used for installation purpose~ Issue 2 Specifications �E DWAR D S RLCD-C RLCD RLED-C RLED24 Operating voltage 24 VDC,continuous. Standby current 99 mA 98 mA 28 mA 6 mA Contact us... Alarm current 115 mA 113 mA 62 mA 34 mA Email: edwards.fire@fs.utc.com. RS-485 communications Class A or Class B,9600 baud Web: www.est-est-fire,com EST is an EDWARDS brand. Data wiring 18 to 14 AWG(1.0 to 2.5 sq mm)twisted pair(6 twists per foot minimum).Maximum wire run is 4,000 ft.(1,219 m) 1016 Corporate Park Drive Remote key switch circuit 5 VDC at 1 mA,power-limited,unsupervised Mebane,NC 27302 Ground fault impedance 0 In Canada,contact Chubb Edwards... Email: inquiries@chubbedwards.com Power wiring 18 to 14 AWG(1.0 to 2.5 sq.mm) Web: www.chubbedwards.com Display area 4 lines of 20 characters each ©2013 UTC Fire&Security Americas Dimensions(H x W x D) 5-5/8 x 8-1/2 x 1-1/2 in.(14.3 x 21.4 x 3.8 cm) Corporation,Inc.All rights reserved. Specifications subject to change Mounting North American 4-inch square electrical box or listed enclosure without notice.Edwards is part of UTC Agency Listing UL,ULC Climate,Controls&Security,a unit of United Technologies Corporation. Operating environment Temperature:32 to 120°F(0 to 49°C)Humidity:0 to 93%RH, noncondensing at 90°F(32°C) Ordering Information Part Description Remote Annunciators RLCD LCD text annunciator without common controls.English. RLCD-R LCD text annunciator without common controls.English.Red. RLCDF LCD text annunciator without common controls.French. � . RLCD-C LCD text annunciator with common controls.English. RLCD-CR LCD text annunciator with common controls.English.Red. RLCD-CF LCD text annunciator with common controls.French. RLED-C 16-pair LED zone annunciator with common controls.English. RLED-CR 16-pair LED zone annunciator with common controls.English.Red. RLED-CF 16-pair LED zone annunciator with common controls.French. Remote Expanders RLED24 24-pair LED zone expander with expander cable and zone card insert. RLED24R 24-pair LED zone expander with expander cable and zone card insert.Red. Enclosures RA-ENC1 One-position enclosure for Remote Annunciator. RA-ENC2 Two-position enclosure for Remote Annunciator and one Remote Expander, including one interconnection cable. RA-ENC3 Three-position enclosure for Remote Annunciator and two Remote Expanders, including two interconnection cables. LSRA-SB Surface Mount Box-for single R Series annunciator. Graphic Annunciator Drivers GCI Graphic Annunciator Driver,provides outputs for common indicators and 32 alarm/ supv zones as well as inputs for common switches.Provided with a snap track for mounting in custom graphic enclosures. Accessories RKEY Remote key switch on plate for enabling or disabling common controls(Lock/ Unlock). 27193-16 Electrical box,surface mount,white,single-gang,for RKEY. Page 4 of 4 D A '. 85005-0128 Not to be used for installation purposes. Issue 2 Intelligent Initiating EST Life Safety & Communications Irv. Manual Pull PULL^ IN CASE. 4F Stations FIRE • SIGA-270, SIGA-270P, PULL FOR SIGA-278 FIRE SIGA-271 `<`*'i. Patented !Tr+ U� law €C MEA ® 7150-1657 0129 S2318 Overview • Break glass operation The SIGA-270 and SIGA-278 series Manual Pull Stations are An up-front visible glass rod on the SIGA-270 discourages tampering. part of EST's Signature Series system.The SIGA-270 Fire Alarm Manual Pull Stations feature our very familiar teardrop shape.They • Intelligent device with integral microprocessor are made from die-cast zinc and finished with red epoxy powder- All decisions are made at the station allowing lower corn- coat paint complemented by aluminum colored stripes and mark- munication speed while substantially improving control panel ings. With positive pull-lever operation,one pull on the station response time. Less sensitive to line noise and loop wiring handle breaks the glass rod and turns in a positive alarm, ensuring properties;twisted or shielded wire is not required. protection plus fool-proof operation.Presignal models(SIGA-270P) • ADA Compliant are equipped with a general alarm(GA)keyswitch for applications Meets ADA requirements for manual pull stations. where two stage operation is required.The up-front highly visible glass rod discourages tampering, but is not required for proper • Electronic Addressing with Non-volatile memory operation. Permanently stores programmable address,serial number, type of device, and job number. Automatically updates historic EST's double action single stage SIGA-278 station is a contempo- information including hours of operation, last maintenance rary style manual station made from durable red colored lexan. To date, number of alarms and troubles, and time and date of last initiate an alarm,first lift the upper door marked"LIFT THEN PULL alarm. HANDLE",then pull the alarm handle. • Automatic device mapping Each station transmits wiring information to the loop control- Standard Features ler regarding its location with respect to other devices on the Note:Some features described here may not be supported by all control sys- circuit. tems.Check your control panel's Installation and Operation Guide for details. • Stand-alone operation • Traditional familiar appearance The station inputs an alarm even if the loop controller's polling SIGA-270 models feature our familiar teardrop design with interrogation stops. simple positive pull action and sturdy die-cast metal body. • Diagnostic LEDs • One stage(GA),two stage(pre-signal),and double action Status LEDs;flashing GREEN shows normal polling;flashing models RED shows alarm state. SIGA-270 models are available for one or two stage alarm • Designed for high ambient temperature operation systems.The single stage double action SIGA-278 features a Install in ambient temperatures up to 120°F(49°C). rugged Lexan housing with keyed reset mechanism. Page 1 of 4 . . 85001-0279 Not to be used for installation Issue 8 .ureuranrr+mruxr.urruxe»aarurr.uwurwru. xrn.err.rryr r araenrxeur.wrrnrrewrusiwrrrrnuuxesrwvdar>rvrrrrpt exsutUiau r.sv+iUr.a eri+ :/ :nras/isfs rtl+kiU eMIUlNU»UJsrit3HdddUseUirll}lYdtiaN/JltNr t ifWUNJYUtbdt/1iU#tufrs+JiNdUi113UJUtFtAHNInU+r.. Application Typical Wiring The operating characteristics of the fire alarm stations are deter- The fire alarm station's terminal block accepts#18 AWG(0.75mm2) mined by their sub-type code or"Personality Code".NORMALLY- to#12 AWG(2.5mm2)wire sizes.See Signature Loop Controller OPEN ALARM-LATCHING(Pesonality Code 1)is assigned by the catalog sheet for detailed wiring requirement specifications. factory; no user configuration is required.The device is configured for Class B IDC operation.An ALARM signal is sent to the loop Wiring Notes controller when the station's pull lever is operated.The alarm con /I\ Refer to Signature Loop Controller manual for maximum dition is latched at the station. wire distance. 2. All wiring is power limited and supervised. Compatibility REARVIEW of 278 Signature Series manual stations are compatible only with EST's I Signature Loop Controller. p 0 0 ._r am, TB2 I I•' Warnings & Cautions 8 7 This device will not operate without electrical power.As fires fre- 1 i uentl causepower interruption,we suggestyou discuss further Red LED I rear,LED q Y p 99 (Alarm/Active) I 0 0 1 (Norrnau safeguards with your local fire protection specialist. '=' I o TBI; _ o III Testing & Maintenance L 1111111111111=1111.. To test(or reset)the station simply open the station and operate DATAIN(.) DATA OUT(.)i the exposed switch.The SIGA-270 series are opened with a tool; DATA IN(-) , DATA OUT(-)1 the SIGA-278 requires the key which is supplied with that station. From Signature controller To Neat Device or Previous Device A The station's automatic self-diagnosis identifies when it is defec- tive and causes a trouble message.The user-friendly maintenance Figure 4. Single Stage Systems program shows the current state of each Signature series device and other pertinent messages.Single devices may be deactivated temporarily,from the control panel.Availability of maintenance features is dependent on the fire alarm system used. REAR VIEW .a • • of 270P.270PB ® O Scheduled maintenance(Regular or Selected)for proper system o operation should be planned to meet the requirements of the Authority Having Jurisdiction(AHJ). Refer to current NFPA 72 and o '_eel 0 ULC CAN/ULC 536 standards. TB2 PER* g ] 65__ Red LED Green LED (Alarm/Active) ( 4 3® 1® ;I (Normal) 2TB1 lrli 1I 11111l I ...._.• 0 O • O IIll 11 • j/DATA IN(-0 -ill , DATA OUT(v) 1 DATA IN(-) , DATA OUT(-) From Signature Controller To Next Device or Previous Device A Figure 5. Two Stage Systems Page 2 of 4 :TA SHEET 85001-0279 Not to be used for installation purposes. Issue 8 Installation Single-stage Signature Series fire alarm manual pull stations mount to North American 21/2 inch(64 mm)deep 1-gang boxes. Two stage presignal(270P)models require 11 inch(38 mm)deep 4-inch square boxes with 1-gang, 1/-inch raised covers.Openings must be angular. Rounded openings are not acceptable. Recommended box:Steel City Model 52-C-13;in Canada, use Iberville Model CI- 52-C-49-1/2. All models include terminals are suited for#12 to#18 AWG(2.5 mm2 to 0.75 mm2)wire size. Edwards recommends that these fire alarm stations be installed according to latest recognized edition of national and local fire alarm codes. Electronic Addressing: The loop controller electronically addresses each manual station, saving valuable time during system com- missioning.Setting complicated switches or dials is not required. Each station has its own unique serial number stored in its on-board memory.The loop controller identifies each device on the loop and assigns a"soft"address to each serial number. If desired,the stations can be addressed using the SIGA-PRO Signature Program/Service Tool. Key-Latch min Compatible Electrical Box MP ICompatible Electrical Box .,.,� Cover Release IX �_� Cover I \ Release �l \ ti Screw ink* 0 • ll 1 1101771111 i P—P ''1 ° \` Back \ �I 7 ° Q. Back `�>1 Plate / , Plate 11) �'IToggle ° Toggle '�L; ° Switch %— ° Switch ,.- ° 0"o a40001. I. N;. 11111 It) t' • IV ��,� Glass Rod � �. ' '' ' �� Glass Rod 000111 ,s, '` Release Lever � A riiiik Figure 1. SIGA-278 installation Figure 2. SIGA-270,SIGC-270F,SIGC-270B installation Cover Release Scrw Compatible Oh �I litio.O Electrical Box 0 w ^ �� red covers i'N. _ I . , 0 -5, 0 ; ...; 1 \ f 4 i , k Back i ])1 ° O Plate ' `��/ \I Cn,� Toggle I �) e ° switch �, N�Rr,pt `� `D o not use C` �� � Glass Rod boxes with .AV._ � Release Lever rounded openings. Figure 3. SIGA-270P,SIGC-270PB installation Page 3 of 4 DATA SHEET 85001-0279 Not to be used for installation purpos Issue 8 • Specifications c.5DWARDSj SIGA-270,SIGC- SIGA-270P, Catalog Number 270F,SIGC-270B SIGC-270PB SIGA-278 Description Single Action Single Action-Two Double Action Contact us... -One Stage Stage(Presignal) -One Stage Email: edwards.fire@fs.utc.com Addressing Uses 1 Module Uses 2 Module Uses 1 Module Web: www.est-tiire.com Requirements Address Addresses Address EST is an EDWARDS brand. Operating Current Standby=250pA Standby=396pA Standby=250pA Activated=400pA Activated=680pA Activated=400pA 1016 Corporate Park Drive Mebane,NC 27302 Construction&Finish Diecast Zinc-Red Epoxy Lexan-Red with with aluminum markings white markings In Canada,contact Chubb Edwards... Type Code Factory Set Email: inquiries@chubbedwards.com Web: www.chubbedwards.com Operating Voltage 15.2 to 19.95 Vdc(19 Vdc nominal) ©2013 UTC Fire&Security Americas Storage and Operating Operating Temperature:32°F to 120°F(0°C to 49°C) Corporation,Inc.All rights reserved. Environment Storage Temperature:-4°F to 140°F(-20°C to 60°C)Humidity:0 to 93% Specifications subject to change RH without notice.Edwards is part of UTC On-board Green LED-Flashes when polled Climate,Controls&Security,a unit of LED Operation On-board Red LED-Flashes w hen in alarm United Technologies Corporation. Both LEDs-Glow steady when in alarm(stand-alone) Compatibility Use With:Signature Loop Controller Agency Listings UL,ULC(note 1),MEA,CSFM Note:SIGC-270F,SIGC-270B and SIGC-270PB are ULC listed only.Suffix"F"indicates French markings. Suffix"B"indicates English/French biting ual markings. Ordering Information Ship Catalog Wt.lbs Number Description (kg) SIGA-270 One Stage Fire Alarm Station, English Markings-UL/ULC Listed SIGC-270F One Stage Fire Alarm Station, French Markings-ULC Listed SIGC-270B One Stage Fire Alarm Station,French/English Markings-ULC Listed SIGA-270P Two Stage(Presignal)Fire Alarm Station,English Markings-UL/ULC Listed 1 (0.5) SIGC- Two Stage(Presignal)Fire Alarm Station,French/English Markings 270PB -ULC Listed -->SIGA 278 Double Action(One Stage)Fire Alarm Station,English Markings -UL/ULC Listed Accessories 32997 GA Key wlT•ag-for pre-signal station(CANADA ONLY) 276-K2 GA Key-for pre-signal station (USA ONLY) 276-K1 Station Reset Key, Supplied with all Key Reset Stations 27165 12 Glass Rods-for SIGA-270 series(CANADA ONLY) 0.1 (.05) 270-GLR 20 Glass Rods-for SIGA-270 series (USA ONLY) 276-GLR 20 Glass Rods-for SIGA-278 series 276E-RSB Surface Mount Box,Red-for SIGA pull stations 1 (0.6) II Page 4 of 4 85001-0279 Not to be used for installation purposes. Issue 8 EST Catalog Intelligent Input/output EST Life Safety & Communications • H i h Power Control Relayr Module 113101 SIGA-CRH . . , .. Description Standard Features The SIGA-CRH High Power Control Relay Module is an address- • High Power Rating able device designed for interface applications that require a high 120/240 VAC or 24 VDC rated contact can be used to control voltage, high current relay.Two identical sets of relay terminals are external appliances such as door closers,fans, dampers etc. provided. Both sets of relay contacts transfer when the module • Provides one relay with two Form C contacts is activated or restored.The state of the output terminals is not Relay accepts 12 to 18 AWG(1.0 to 4.0 mm2)wiring from two supervised. sources The module requires one address on the signaling line circuit • Automatic device mapping (SLC).The address is assigned electronically.There are no ad- Signature modules transmit information to the loop controller dress switches to set. regarding their circuit locations with respect to other Signature devices on the wire loop. • Removable terminal blocks Easy wiring and module replacement. • Electronic addressing Programmable addresses are downloaded from the loop con- troller or PC;there are no switches or dials to set. • Intelligent device Distributed intelligence allows lower communication speed with substantially improved control panel response time and less sensitivity to line noise and loop wiring properties;twisted or shielded wire is not required. Pagel of 4 DATA SHEET 85001-0644 Not to be used for installation purpose Issue 1 W .prJYIN4nsxu.. ••"" x ,w,i.JriJ.rsF ,,,,Nbdxs/iiFrt/1 1 Jen„„,..H.u+lNfla!/b1HJNtt1#lutlAl-- `."•." '°'. 4p:. Application Installation Personality code Compatible electrical box Use Personality Code 8 to configure the SIGA-CRH module: ----------- Personality code 8:Signal-dry contact output.Configures ® SIGA-CRH the module as a dry relay contact to control external appli- ances(door closers,fan controllers, dampers)or equipment shutdown. = ° �% Wall plate Indication Aiiiiiit �tThe status LED shows the state of the module through the coverit plate: �• Normal:Green LED flashes (�; ° o° • Alarm/active: Red LED flashes `'Compatibility The SIGA-CRH is part of the Signature Series intelligent process- ing and control platform. It is compatible with EST3, EST3X,and Consult the SIGA-CRH High Power Control Relay Module Installa- iO Series control panels. tion Sheet for details. Warnings&Cautions The SIGA-CRH will not operate without electrical power.As fires Wiring frequently cause power interruption,we suggest you discuss further safeguards with your local fire protection specialist. O o O 1 EDWARDS recommends that this module be installed according -+ to latest recognized edition of national and local fire alarm codes. o O (-7_:--) (3) Nc2 8-- (4) — cz g (5) —(7) Testing&Maintenance �� NO2 la (6) SIGA-CRH automatic self-diagnosis identifies when it is defective I 2 ® (4) — and causes a trouble message.The user-friendly maintenance ''_ program shows the current state of each module and other per- No (6) —(8) tinent messages.Single modules may be turned off(deactivated) — temporarily,from the control panel.Availability of maintenance o 0 features is dependent on the fire alarm system used.Scheduled (2) maintenance(Regular or Selected)for proper system operation 0 o 0 611) should be planned to meet the requirements of the Authority Hav- ing Jurisdiction(AHJ). Refer to current NFPA 72 and ULC CAN/ (1) Signaling line circuit(SLC)from previous device ULC 536 standards. (2) Signaling line circuit(SLC)to next device (3) Power-limited and supervised Electronic Addressing (4) Normally closed contact(NC) The loop controller electronically addresses the SIGA-CRH,saving (5) Common contact(C) valuable time during system commissioning.Setting complicated (6) Normally open contact(NO) switches or dials is not required.The module has its own unique (7) Relay terminal set 2. serial number stored in its on-board memory. Not supervised.Power-limited unless connected to a nonpowerlimited source.If the source is nonpower-limited,eliminate the power-limited mark and maintain a minimum of 0.25 in.(6.4 mm)space from power-limited wiring.For other mounting methods,see enclosure and bracket installation sheets to maintain separation of power-limited and nonpower-limited wiring.The wire size must be capable of handling fault current from a nonpower-limited source. —or— Use type FPL,FPLR,FPLP,or permitted substitute cables,provided these power-limited cable conductors extending beyond the jacket are separated by a minimum of 0.25 in.(6.4 mm)space or by a nonconductive sleeve or nonconductive barrier from all other conductors.Refer to the NFPA 70 National Electrical Code for more details. (8) Relay terminal set 1.Identical to(7). Page 2 of 4 DATA SHEET 85001-0644 Not to be used for installation purposes Issue 1 Specifications Ordering Information SLC operating voltage 15.20 to 19.95 VDC Catalog Ship Weight Description SLC current Number lbs(kg) Standby 75 pA max. SIGA-CRH High Power Control Relay Module 0.4(0.15) Activated 75 pA max. Contact ratings[1][2] 240 V 50/60 Hz 7 A(PF 0.75),1.5 A(PF 0.35) 120 V 50/60 Hz 7 A(PF 0.75),3.0 A(PF 0.35) 24 VDC 6 A resistive Audio switching 0 to 20 kHz[3] Relay type 2 Form C,programmable Relay ready delay From power up 30 s max.(includes initial state set) From previous activation 5 s max.(one activation) 8 s max.(two activations,1 s apart) Circuit designation Signaling line circuits Class A,Style 6 or Class B,Style 4. Refer to the control panel technical publications for SLC wiring details. Relay circuits Class E Number of SIGA-CRH per SLC 60 max. Wire size 12 to 18 AWG(1.0 to 4.0 mm2) North American double-gang x 2-1/8 Compatible electrical boxes in.(54 mm)deep box North American standard 4 in.square x 2-1/8 in.(54 mm)deep box Agency Listings CAN/ULC-S527,UL 864 Operating environment Temperature 32 to 120°F(0 to 49°C) Relative humidity 0 to 93%,noncondensing Storage temperature -4 to 140°F(-20 to 60°C) [1] Provide external fusing and back-EMF mitigation as required by your application.Do not use the SIGA-CRH in a mixed application, where one set of relay terminals has high-power requirements and the other set carries a low-power signal,as this may result in physical contamination of the low-power signal contacts. [2] The minimum load required in order to avoid long-term contact oxidation is 100 mA and 12 V. [3] Power must not exceed the contact ratings shown for a given PF (power factor). Page 3 of 4 DATA SHEET 85001-0644 Not to be used for installation purposes. Issue 1 �DWARDS Contact us... Email: edwards.fire@fs.utc.com Web: www.est-fire.com EST is an EDWARDS brand. 1016 Corporate Park Drive Mebane,NC 27302 In Canada,contact Chubb EDWARDS... Email: inquiries@chubbedwards.com Web: wwwchubbedwards.com ©2015 United Technologies Corpora- tion.All rights reserved.Specifications subject to change without notice. EDWARDS is part of UTC Building& Industrial Systems,a unit of United Technologies Corporation. Page 4 of 4 DATA SHEET 85001-0644 Not to be used for installation purposes. Issue 1 EST Catalog 0.Intelligent Input-Output EST Life Safety & Communications Input Modules • • • SIGA-CT1 , SIGA-CT1 HT, ' SIGA-CT2, SIGA-MCT2 w Y4 "I • g Y 4Z z,, : 4. r SIGA-MCT2 (" ® MEA (Efi ® LC Application Notes 73°"657: Avaasble 0121 S3424 Overview Standard Features The SIGA-CT1 Single Input Module, SIGA-CT1 HT High Tern- • Multiple applications perature Single Input Module and SIGA-CT2/SIGA-MCT2 Dual Including Alarm,Alarm with delayed latching(retard)for water- Input Modules are intelligent analog addressable devices used to flow applications,Supervisory,and Monitor.The installer selects connect one or two Class B normally-open Alarm, Supervisory,or one of four"personality codes"to be downloaded to the mod- Monitor type dry contact Initiating Device Circuits(IDC). ule through the loop controller. The actual function of these modules is determined by the"personal- • SIGA-CT1 HT rated for high temperature environments ity code"selected by the installer.This code is downloaded to the Suitable for attic installation and monitoring high temperature module from the Signature loop controller during system configura- heat detectors. tion. • Plug-in(UIO)or standard 1-gang mount The input modules gather analog information from the initiating UIO versions allow quick installation where multiple modules are required.The 1-gang mount version is ideal for remote loca devices connected to them and convert it into digital signals. The module's on-board microprocessor analyzes the signal and tions that require a single module. decides whether or not to input an alarm. • Automatic device mapping Signature modules transmit information to the loop controller The SIGA-CT1,SIGA-CT1 HT and SIGA-CT2 mount to standard regarding their circuit locations with respect to other Signature North American 1-gang electrical boxes,making them ideal for lo- devices on the wire loop. cations where only one module is required.Separate I/O and data • Electronic addressing loop connections are made to each module. Programmable addresses are downloaded from the loop con- The SIGA-CT1 HT module operates at an expanded temperature troller,a PC,or the SIGA-PRO Signature Program/Service Tool. range of 32°F to 158°F(0°C to 70°C)for those applications There are no switches or dials to set. requiring more extreme environmental temperature variation. • Stand-alone operation The SIGA-MCT2 is part of the UIO family of plug-in Signature The module makes decisions and inputs an alarm from initiat- Series modules. It functions identically to the SIGA-CT2, but ing devices connected to it even if the loop controller's polling takes advantage of the modular flexibility and easy installation that interrogation stops. (Function availability dependent upon control characterizes all UIO modules.Two-and six-module UIO mother- panel.) boards are available.All wiring connections are made to terminal • Ground fault detection by address blocks on the motherboard. UIO assemblies may be mounted in Detects ground faults right down to the device level. Edwards enclosures. Pagel of 4 DATA SHEET 85001-0241 Not to be used for installation purpose Issue 8 Signature Series Overview U10Motherboard The Signature Series intelligent analog-addressable system from 6-32 9 g 9 Y Self-tapping Edwards Security is an entire family of multi-sensor detectors and it screws mounting bases, multiple-function input and output modules, network and non-network control panels,and user-friendly main- -fi -"l Plug-in(U10) Captive tenance and service tools.Analog information from equipment Module screws connected to Signature devices is gathered and converted into digital signals.An onboard microprocessor in each Signature de- __--_-___'-1(1 vice measures and analyzes the signal and decides whether or not ; #6 Flat washers to input an alarm.The microprocessor in each Signature device provides four additional benefits-Self-diagnostics and History _ --Cabinet or electrical enclosure Log,Automatic Device Mapping,Stand-alone Operation and Fast, Stable Communication. Electronic Addressing-The loop controller electronically ad- Self-diagnostics and History Log-Each Signature Series dresses each module,saving valuable time during system com- device constantly runs self-checks to provide important mainte- missioning. Setting complicated switches or dials is not required. nance information.The results of the self-check are automatically Each module has its own unique serial number stored in its updated and permanently stored in its non-volatile memory.This on-board memory.The loop controller identifies each device on information is accessible for review any time at the control panel, the loop and assigns a"soft"address to each serial number. If PC,or using the SIGA-PRO Signature Program/Service Tool. desired,the modules can be addressed using the SIGA-PRO Automatic Device Mapping-The Signature Data Control- Signature Program/Service Tool. ler(SDC)learns where each device's serial number address is Edwards recommends that this module be installed according to installed relative to other devices on the circuit.The SDC keeps a latest recognized edition of national and local fire alarm codes. map of all Signature Series devices connected to it.The Signature Series Data Entry Program also uses the mapping feature.With interactive menus and graphic support,the wired circuits be- Application tween each device can be examined. Layout or"as-built"drawing information showing branch wiring(T-taps), device types and their The duty performed by the SIGA-CT1 and SIGA-CT2/MCT2 is de- address are stored on disk for printing hard copy. termined by their sub-type code or"Personality Code".The code is selected by the installer depending upon the desired application Installation and is downloaded from the loop controller. SIGA-CT1,SIGA-CT1 HT and SIGA-CT2:modules mount to One personality code can be assigned to the SIGA-CT1.Two per- North American 2'/2 inch(64 mm)deep 1-gang boxes and 1 1 inch sonality codes can be assigned to the SIGA-CT2/MCT2. Codes (38 mm)deep 4 inch square boxes with 1-gang covers and SIGA 1, 2,3 and 4 can be mixed on SIGA CT2/MCT2 modules only.For MP mounting plates.The terminals are suited for#12 to#18 AWG example, personality code 1 can be assigned to the first address (2.5 mm2 to 0.75 mm2)wire size. (circuit A)and code 4 can be assigned to the second address (circuit B). NORMALLY-OPEN ALARM-LATCHING(Personality Code 1) Compatible electrical box AN � -Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact initiating devices such 11 ll !1.. 0.\\. ' as Pull Stations, Heat Detectors,etc.An ALARM signal is sent to the loop controller when the input contact is closed.The alarm condition is latched at the module. Wall plate,white (t-gang) NORMALLYOPEN ALARM- DELAYED LATCHING(Person- y/ ality Code 2)-Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact initiat- ing devices such as Waterflow Alarm Switches.An ALARM signal is sent to the loop controller when the input contact is closed for 0 Q approximately 16 seconds.The alarm condition is latched at the module. Status LEDs NORMALLY-OPEN ACTIVE- NON-LATCHING(Personality Q� Code 3)-Assign to one or both circuits.Configures either circuit LED viewing ports A or B or both for Class B normally-open dry contact monitoring Q input such as from Fans, Dampers, Doors,etc.An ACTIVE signal is sent to the loop controller when the input contact is closed.The active condition is not latched at the module. SIGA-MCT2:mount the UIO motherboard inside a suitable NORMALLY-OPEN ACTIVE-LATCHING(Personality Code Edwards enclosure with screws and washers provided. Plug the 4)-Assign to one or both circuits. Configures either circuit A or SIGA-MCT2 into any available position on the motherboard and B or both for Class B normally open dry contact monitoring input secure the module to the motherboard with the captive screws. such as from Supervisory and Tamper Switches.An ACTIVE signal Wiring connections are made to the terminals on the motherboard is sent to the loop controller when the input contact is closed.The (see wiring diagram). UIO motherboard terminals are suited for#12 active condition is latched at the module. to#18 AWG(2.5 mm2 to 0.75 mm2)wire size. Page 2 of 4 DATA SHEET 85001-0241 Not to be used for installation purposes. Issue 8 Typical Wiring Modules will accept#18 AWG(0.75mm2), #16(1.0mm2), and#14AWG(1.50mm2), and#12 AWG(2.50mm2)wire sizes. Note:Sizes#16 AWG(1.0mm2)and#18 AWG(0.75mm2)are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating(Slave)Device Circuit Wire Specifications Maximum Allowable Wire Resistance 50 ohms(25 ohms per wire)per Circuit Maximum Allowable Wire Capacitance 0.1 pF per Circuit For Design Reference: Wire Size Maximum Distance to EOLR #18 AWG(0.75 mm2) ---_--_------__--. #16 AWG(1.00 mm2) 4,000 ft(1,219 m) #14 AWG(1.50 mm2) #12 AWG(1.50 mm2) Typical N.O.Initiating Device Typical N.O.Initiating Device 1 INPUT 1 INPUT 2 I' ---Y—Y—' 6 A A®Style B(Class B) 411� � � TB2 I.. li '. I T82 — 8 7 UL/ULC Listed Style B(Class B) • • • 47KII EOL UL/ULC Listed 8 7 a s j UL/ULC Listed 47Kg EOL Ot Q2 A • • • 47Kf3 EOL Red LED i Green LED Red LED { (Alarm/Active) I © © II (Normal) (Alarm/Active) --+0 t0 4-- Green LED 4 3 2 1 1 TBI iIII®®®. TBIa®m®® tDATA IN(+) -all 1 _ ► (+)DATA OUT j(DATA IN(+)> InI —DATA OUT(+)l} DATA IN(-) , DATA OUT(-)1 t DATA IN(-)> ) l --ill..DATA OUT(-)1 To Next Device From Signature Controller YY7 To Next Device From Signature Controller or Previous Device A or Previous Device A 3 SIGA-CT1,SIGA-CT1 HT SIGA-CT2 1 1 11 Typical NO Initiating Device 1 1 NOTES uL/uLC Listed 4)MN EOL bIb Input2 PINIDI UL/U Clisted EOL A Maximum 25 Ohm resistance per wire. A Maximum#12 AWG(2.5 mm2)wire;Minimum#18 AWG(0.75 mm2). ... AAA A ARefer to Signature controller installation sheet for wiring specifications. n Maximum 10 Vdc©350 pA MCT2 A The SIGA-U106R and the SIGA-U102R do not come with TB14. t 2 3 4 DIa11 series motherboard 6 All wiring is supervised and power-limited. + eeaav Data In Q 7 These modules will not support 2-wire smoke detectors. Signature 3 �a.�9 , No connections required for Data ii 1.. , MC12 Grua / - ,oheNnwdules may require Data out+ nods. Warnings & Cautions .ram Greco LED INormall This module will not operate without electrical power.As fires fre- Red LEDwcwel 2211 quently cause power interruption,we suggest you discuss further safeguards with your local fire protection specialist. No connections or jumper settings required for MC12. Compatibility SIGA-MCT2 These modules are part of EST's Signature Series intelligent processing and control platform.They are compatible with EST3, EST3X and iO Series control panels. Page 3 of 4 DATA SHEET 85001-0241 Not to be used for installation purpose: Issue 8 Specifications EDWAR DS Catalog Number SIGA-CT1HT J SIGA-CT1 SIGA-CT2 SIGA-MCT2 Description Single Input Module Dual Input Module Type Code 48(factory set)Four sub-types 49(factory set)Four sub-types Contact us... (personality codes)are available (personality codes)are available Email: edwards.fire@fs.utc.com Address Requirements Uses One Module Address Uses Two Module Addresses Web: www.est-fire.coni Operating Current Standby=250NA; Standby=3961A; EST is an EDWARDS brand. Activated=400pA Activated=680NA 1016 Corporate Park Drive Operating Voltage 15.2 to 19.95 Vdc(19 Vdc nominal Mebane,NC 27302 Construction High Impact Engineering Polymer In Canada,contact Chubb Edwards... Mounting North American 21 inch(64 mm)deep one-gang box- U102R/6R/6 Email: inquiries@chubbedwards.com es and 1 Y inch (38 mm)deep 4 inch square boxes Motherboard Web: www.chubbedwards.com with one-gang covers and SIGA-MP mounting plates 0 2013 UTC Fire&Security Americas Operating Environment 32°F to 158°F 32°F to 120°F(0°C to 49°C) Corporation,Inc.All rights reserved. (0°C to 70°C) Specifications subject to change Storage Environment -4°F to 140°F(-20°C to 60°C);Humidity:0 to 93%RH without notice.Edwards is part of UTC Climate,Controls&Security,a unit of LED Operation On-board Green LED-Rashes when polled;On-board Red LED- United Technologies Corporation. Flashes when in alarm/active. Both LEDs-Glow steady when in alarm(stand-alone) Compatibility Use with Signature Loop Controller Agency Listings UL,ULC,MEA,CSFM Ordering Information Catalog Ship Wt. Number Description lbs k � 9) SIGA-CT1 Single Input Module—UL/ULC Listed 0.4(0.15) SIGA-CT1 HT Single Input Module High Temperature Operation UL/ULC Listed 0.4(0.15) --'SIGA-CT2 Dual Input Module— UL/ULC Listed 0.4(0.15) SIGA-MCT2 Dual Input Plug-in(UIO)Module —UL,ULC Listed 0.1 (0.05) Related Equipment 27193-11 Surface Mount Box-Red,1-gang 1.0(0.6) 27193-16 Surface Mount Box-White,1-gang 1.0(0.6) SIGA-U102R Universal Input-Output Module Board w/Riser Inputs 0.32(0.15) —Two Module Positions SIGA-U106R Universal Input-Output Module Board w/Riser Inputs 0.62(0.28) —Six Module Positions SIGA-U106 Universal Input-Output Module Board —Six Module Positions 0.56(0.25) MFC-A Multifunction Fire Cabinet—Red,supports Signature Module 7.0(3.1) Mounting Plates SIGA MB4 Transponder Mounting Bracket(allows for mounting 0.4(0.15) two 1-gang modules in a 2-gang box) SIGA-MP1 Signature Module Mounting Plate,1 footprint 1.5(0.70) SIGA-MP2 Signature Module Mounting Plate,1/2 footprint 0.5(0.23) SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02(0.46) Page4of4 DATA SHEET 85001-0241 Not to be used for installation purposes. Issue 8 EDWARDS'Catalog F Intelligent Initiating Devices EDWARDB LIFE SAFETY & INCIDENT MANAGEMENT Intelligent � „,r Multisensor Smoke ..... -. and Heat Detector ... Nr\ i _.� ..-.. _ \, / ,,... SIGA-OSHD .. ' -�aw�o-., , / i a ® 7272 1657: 0512 Overview Standard Features The Signature Optica Series SIGA-OSHD smoke detector • Multi-criteria optical smoke sensing technology brings advanced optical(photoelectric)sensing technology to a Integrates optical smoke with rate-of-rise heat sensing practical design that increases efficiency,saves installation time, • Wide 0.5 to 4.36%/ft.(1.6 to 13.6%/m)smoke obscuration cuts costs,and extends life safety and property protection . Integrated nuisance rejection reducing unwanted alarms from r; capabilities.Continuous self-diagnostics ensure reliability general cooking particulates over the long-haul,while environmental compensation helps F reduce maintenance costs. • Uses existing wiring The SIGA-OSHD provides an optical smoke sensor and a • Listed to UL 268 7th edition rate-of-rise heat sensor with a fixed temperature setting. • Automatic device mapping Together these sensors efficiently detect smoldering fires, as well as fast flaming fires. • Sensor Markings Provide Easy Testing Identification '; Like all Signature Optica Series detectors,the SIGA-OSHD is an • Up To 250 Total Signature Addresses Per Loop intelligent device that gathers analog information from multiple • Two levels of environmental compensation ' optical sensors,converting this data into digital signals.Utilizing • Two levels of dirty detector warning dual optical wavelengths combined with multiple detection angles, d the SIGA-OSHD differentiates particles that are not representative • Twenty pre-alarm settings fof actual smoke.Particle data is input into digital filters which • Five sensitivity settings r, feed a series of ratios removing signal patterns that are typical of nuisance sources,thus reducing unwanted alarms.To make an • Non-volatile memory alarm decision,the detector's on-board microprocessor measures • Electronic addressing and analyzes all optical sensor readings and compares this % information to preprogrammed settings. • Automatic day/night sensitivity adjustment • Bicolor(green/red)status LED 1 • Standard,relay,fault isolator,and audible mounting bases a Note:Some features described here may not be supported by all control systems.Check your control panel's Installation and ( Operation Guide for details. , Pagel of DATA SHEE T E85001-1003 F Not to be used for installation purposes. Issue 1.3 fi �F • Application Automatic Device Mapping-The loop controller learns where each device's serial number address is installed relative to other Smoke detection devices on the circuit.The mapping feature provides supervision The SIGA-OSHD detects particles from a wide range of of each device's installed location to prevent a detector from being combustion sources and will trigger an alarm when smoke reinstalled(after cleaning etc.)in a different location from where it density in the chamber reaches preprogrammed level.Thanks to was originally. its high-performance reflective response technology,the smoke sensor responds quickly and reliably to a wide range of fire types, Fast Stable Communication On board intelligence means less including both fast and slow burning fires fueled by combustibles information needs to be sent between the detector and the loop typically found in modern multi use buildings. controller.Other than regular supervisory polling response,the detector only needs to communicate with the loop controller when Heat detection it has something new to report. SIGA-OSHD's on-board rate-of-rise heat sensor provides a 15°F (9°C)per minute function for the detection of fast-developing Accessories fires while also providing a 135°F(57.2°C)fixed detection Detector mounting bases have wiring terminals that are threshold.The heat sensors monitor the temperature of the accessible from the"room-side"after mounting the base to the air and determines whether an alarm should be initiated. electrical box.The bases mount to North American 1-gang boxes and to 31/2 inch or 4 inch octagon boxes,11/2 inches(38 mm) Compatibility deep.They also mount to European BESA and 1-gang boxes with The Siga-OSHD detector is compatible only with control panels 60.3 mm fixing centers.The SIGA SB4,SIGA RB4,and SIGA 184 using a Signature Loop controller. mount to North American 4 inch sq.electrical boxes in addition to the above boxes.They include the SIGA-TS4Trim Skirt,which is used to cover the"mounting ears"on the base.Sounder bases Installation mount to a 4 inch square boxes only. Signature Series detectors mount _ , to North American 1-gang boxes, � ` , f 3 1/2 inch or 4 inch octagon c=3 II , " \t. Self-locking tab i. �„ �. j *r , ,�, boxes,and to 4 inch square •-sue /, electrical boxes 1-1/2 inches SIGA-AB4G/T/LF SIGA-SB SIGA-IB SIGA-RB SIGA-LED (38 mm)deep.They mount to Audible Base Standard Base Isolator Base Relay Base Remote LED European BESA and 1-gang boxes with 60.3 mm fixing LED Indicator Remote LED SIGA-LED-The remote LED connects to the centers.See mounting base SIGA-SB or SIGA-SB4 Standard Base only.It features a North installation and wiring for American size 1-gang plastic faceplate with a white finish and more information. red alarm LED. SIGA-TS4 Trim Skirt-Supplied with 4 inch bases,it can also Testing & Maintenance be ordered separately to use with the other bases to help hide surface imperfections not covered by the smaller bases. Scheduled maintenance(regular or selected)for proper detector operation should be planned to meet the requirements Sounder Bases-Signature Series sounder bases are designed of the Authority Having Jurisdiction(AHJ).Refer to current for use where localized or group alarm signaling is required. NFPA 72,NFPA 720,and ULC CAN/ULC 536 standards. • SIGA-AB4G bases provide sounder capability to Signature Smoke Sensor Sensitivity Series smoke and heat detectors.They are not for use with The SIGA-OSHD determines when its optical sensor is dirty or devices that include a CO sensor. defective and can transmit sensitivity data to the loop controller. • SIGA-AB4GT bases provide sounder capability to Signature A sensitivity report can also be printed to satisfy NFPA sensitivity Series smoke and heat detectors,as well as Signature measurements,which must be conducted at the end of the first detectors that include a CO Sensor when used with a SIGA- year and every two years thereafter.The availability of maintenance TCDR Temporal Pattern Generator to separate CO(TC4)and features depends on the fire alarm system used. Fire(TC3)tone patterns. • SIGA-AB4G-LF bases provide 520 Hz low frequency Sensing and reporting technology sounder capability to Signature Series smoke and heat detectors,as well as Signature detectors that include a CO The microprocessor in each detector provides additional Sensor when used with a SIGA-TCDR Temporal Pattern benefits—Self-diagnostics and History Log,Automatic Device Generator to separate CO(TC4)and Fire(TC3)tone patterns. Mapping and Fast,Stable Communication. The SIGA-AB4G-LF is suitable for applications requiring low Self-diagnostics and History Log-Each Signature Series frequency audible tones. detector constantly runs self-checks to provide important maintenance information.The results of the self-check are automatically updated and permanently stored in the detector's non-volatile memory. Page2of4 DATA SHEET E85001-1003 Not to be used for installation purposes. Issue 1.3 Typical Wiring Audible Sounder Bases,Fire Mode The detector mounting bases accept#18 AWG(0.75mm2) AB4G,AB4GT and AB4G-LF sounder bases #16(1.es. 4 AWG (1.0m 2),and#12 AWG(2.5mm2) r.— arewire sizes.Sizes#16 AWG(1.0mm2)and#18 AWG(0.75mm2)preferred for ease of installation. SIGA-AB4GT, SIGH-A84G-LF: SIGA-A84G and ® p p dumper cuts® Output Mode SIGA-AB4G-LF: Default=Fire Standard Detector Base,SIGA-SB,SIGA-SB4 Volume Setting Cut/remove jumper Default High for Fire plus CO This is the basic mounting base Remote LED Cut/remove for EDWARDS Signature Series Maxlesatance jumper for SIGA-A84G: g low dB ® ® Tone Setting detectors.The SIGA-LED 1•t Per wile Default=Temporal + must not BateStl SIG. SIC. our DM. IN/OUT Cut/remove jumper Remote LED is supported ioOnms y 0112,,, r III^iii Ii^iji^iji for Steady b this Base. oTerm Description , rrrrrr1 Not Used �,� C+?/.1_� /1\ C+?C+? 2 DATA IN/OUT(+) i„.�ym.�� .i .e ,. 3 DAt TA IN l , � ,': Milli 4 DATA IN , ' , 4 Remote LED(-) DATA IN I-I I DATA 0UT(-) 24 Vdc in - - 24Vdc out 5 Remote LED(+) From power supply ■-■' 6 Not Used or previous base + .,' + To next base or EOL relay 7 DATA OUT(-) DATA IN(+) DATA OUT(+) From Sgrptumcontroi r To Next L VCe or Previous Device Data in - Data out From Signature Controller + + to next Signature device or previous device Isolator Detector Base,SIGA-IB,SIGA-IB4 This base includes a built-in line fault isolator for use on Class A circuits.A detector must be installed for it to operate.The isolator base does not support the SIGA-LED Remote LED. Warnings &Cautions The isolator operates as follows: • This detector does not operate without electrical power. a short on the line causes all • As fires frequently cause power interruption,discuss further isolators to open within 23 msec. r �,. safeguards with the local fire protection specialist. - at 10 msec intervals,beginning • This detector does not sense fires in areas where smoke or on one side of the Class A heat cannot reach the detector.Smoke or heat from fires in circuit nearest the loop -•:.. _ ;: walls,roofs,or on the opposite side of closed doors may not controller,the isolators . reach the detector. close to provide the • In Canada,install according to the CAN/ULC-5524 next isolator down Standard for the Installation of Fire Alarm Systems,the the line with power. CSA C22.1 Canadian Electrical Code,and the local authority - when the isolator next having jurisdiction. to the short closes,it Term Description 1 Not Used reopens within 10 msec. 2 DATA IN/OUT(+) • Upon completion of the original installation and following any 3 DATA IN(-) modifications or additions to the system,perform a calibrated The process repeats beginning on 4 Not Used 5 Not Used sensitivity test per NFPA code.Signature Series devices the other side of the loop controller. 6 DATA OUT(-) canperform this test and thepanel cangenerate a system 7 Not Used y sensitivity report. Relay Detector Base,SIGA-RB,SIGA-RB4 This base includes a relay. _ Normally Open or Normally Closed operation is selected during installation.The dry contact is rated for 1 amp . (pilot duty)@ 30 Vdc.The relay's position is supervised MILleir to avoid accidentally jarring it =""�`j�l / out of position.The SIGA-RB ' can be operated as a control relay if programmed to do so at the control anel.The relayTerm Description p 1 Normally Open base does not support the CONTACT RATING 2 DATA IN/OUT(+) SIGA-LED1.0 Amp @3oVDc 3 Common Remote LED. (Pilot Duty) 4 DATA IN(-) 5 Not Used 6 Normally-Closed 7 DATA OUT(-) Page3of4 DATA SHEET E85001-1003 Not to be used for installation purposes. Issue 1.3 Dimensions �DWARDS ����� LIFE SAFETY&INCIDENT MANAGEMENT ' Contact us za e O 111' Phone: 800-655-4497(Option 4) IrmdioNoa t11,: !� Email: edwards.fireAcarriencom �\`V�.—�� 7/ Website: edwardsfiresafety.com „ee 8985 Town Center Pkwy Bradenton,FL 34202 2020 Carrier aaa All rights reserved. Specifications Operating voltage 15.20 to 19.95 VDC Normal operating current 32 pA Alarm current 45 pA Vibration level 10 to 35 Hz,with an amplitude of 0.01 in. Smoke Sensitivity Range UL/ULC:0.5 to 4.36%/ft.(1.6 to 13.6%/m)obscuration Rate-of-rise rating 15°F/min(8°C/min) Fixed temperature rating 135°F(57.2°C).Actual alarm point 129 to 141°F(53.9 to 60.6°C). Air velocity 0 to 4,000 ft./min(0 to 20.32 m/s) Wall mounting 12 in.(305 mm)max.from ceiling Spacing,heat detectors Max.50 ft.(15.2 m)centers Compatible bases See Ordering Information Compatible detector testers Testifire 1000,Testifire 2000 Operating environment 32 to 100°F(0 to 38°C),0 to 93%RH,noncondensing Construction High Impact Engineering Polymer,White Storage temperature -4 to 140°F(-20 to 60°C) Environmental compensation Automatic Agency Listings CAN/ULC-5529,CAN/ULC-5530,UL 268-7,UL 268A, UL 521,CSFM Ordering Information Catalog Description Ship Wt. Number _ lbs(kg) SIGA-OSHD Intelligent Multisensor Smoke and Heat Detector 0.4(0.16) Compatible Bases SIGA-SB Detector Mounting Base-Standard SIGA-SB4 4-inch Detector Mounting Base c/wTrim Skirt SIGA-RB Detector Mounting Base w/Relay _ SIGA-RB4 4-inch Detector Mounting Base w/Relay,c/wTrim Skirt 0.2(.09) SIGA-IB Detector Mounting Base w/Fault Isolator SIGA-IB4 4-inch Detector Mounting Base w/Fault Isolator,c/wTrim Skirt SIGA-LED Remote Alarm LED(not for EN54 applications) SIGA-AB4G-LF Low Frequency Audible(Sounder)Base for CO and Fire Detectors 0.3(0.15) SIGA-AB4GT Audible(Sounder)Base for CO and Fire Detectors 0.3(0.15) SIGA-TS4 Trim Skirt(supplied with 4-inch bases) 0.1 (.04) SIGA-TSB Trim Skirt for 4"Base,Black 0.1 (.04) SIGA-DMP Detector Mounting Plate 3.0(1.4) SIGA-RTA Detector Removal Tool SIGA-VA Detector Cleaning Tool Page4of4 DATA SHEET E85001-1003 o Not to be used for installation purposes. Issue 1.3 t.t Intelligent Initiating E T S y„ Life Safety & Communications Intelligent Duct � � �� , „ .. Smoke Detector x SIGA—SD a w 0 MEA 32022357 S853 Overview Standard Features The Edwards SuperDuct Signature Series smoke detector is the • Less than 2"deep for easy installation and applications where most advanced and most reliable device in its class. Designed for space is tight easy installation and superb reliability,SuperDuct represents the • -4°F to 158°F(-20°C to 70°C) operating range with 100 ft/min. perfect balance of practical design and advanced technology. to 4,000 ft/min air velocity rating assures reliability under harsh SuperDuct detectors feature a unique design that speeds instal- environmental conditions lation and simplifies maintenance.Removable dust filters,confor- • Status LEDs remain visible through clear assembly cover mally coated circuit boards,and optional water-resistant gaskets keep contaminants away from components, ensuring years of • Cover monitor switch for added security trouble-free service.When cleaning is required,the assemblies • Standard sampling tube spacing for easy drop-in migration come apart easily and snap back together in seconds. from other detectors A Signature Series photoelectric sensor is incorporated into • Sampling tube can be installed with or without the cover in the design of each SIGA-SD duct smoke detector.This sensor place and can be rotated in 45-degree increments to ensure inherits the power and benefits of this exceptional line of intelligent proper alignment with duct airflow devices. • 15.2 to 19.95 Vdc operation Signature Series sensors gather analog information from their • smoke sensing elements and convert it into digital signals.The Magnet activated test switch sensor measures and analyses these signals and compares the • One Form C auxiliary alarm relay for controlling ancillary equip- information to historical readings and time patterns to make an ment(e.g., HVAC controls) alarm decision. Digital filters remove signal patterns that are not • No special tools required for easy access to field connections typical of fires,which virtually eliminates unwanted alarms. • Signature Series intelligence WARNING: Duct detectors have specific limitations. Duct detectors are not a • Environmental compensation with differential sensing for reli- substitute for an open area smoke detector. Duct detectors are not a substitute able, stable, and drift-free sensitivity for early warning detection or a replacement for a building's regular fire detection system.Smoke detectors are not designed to detect toxic gases which can build up • Wide 0.79%to 2.46%obscuration/ft.smoke sensitivity to hazardous levels in some fires.These devices wit not operate without electrical power.As fires frequently cause power nterruptions,Edwards suggests you discuss • Identification of dirty or defective detectors further safeguards with your local fire protection specialist. Pagelof4 DATA SHEET 85001-0584 Not to be used for installation purpos_ Issue 6 • Application The sampling tube may be installed from either the duct side of SuperDuct detectors are ideally suited to duct smoke detection the assembly or from inside the sensor compartment, as preferred by the installer.(The exhaust tube must be installed from the duct applications where early indication of combustion is required within side.)Sampling tubes may be rotated in 45-degree increments so the confined space of ventilation ductwork. Its primary purpose that air-holes can be aligned to allow the unit to be mounted at is to provide early warning of an impending fire and to prevent virtually any angle relative to the air flow. smoke from circulating throughout the building. It is typically used to detect smoke in the supply side of the HVAC system but can In installations where the duct smoke detector's controls and indica- provide supervision of the return side as well. tors are hidden from view,a remote test station or an LED indicator can be connected to the detector to provide these functions. Protected premises Remote Remote Test Stations Alarm relay test output station • ; Labor-saving Remote Test/Reset stations provide alarm testing from the convenience of a remote - --' ` ' • location.Tests can be performed quickly and safely _Duct smoke C Return —without having to climb to the roof. Magnetically- - detector air HVAC --t' -`- operated and key-operated one-gang models are unit _ ^"^^^` available. Signature SuperDuct detectors are also — _Duct smoke r—>Supply compatible with SIGA-LED remote alarm LED. — detector air _._....__...___._..-- _._.__..._.__.___._..__.._ ____._.._ Air velocity in the duct as low as 100 ft/min.maintains adequate Alarm relay air flow into the sensor smoke chamber through air holes in the air output y Remote sampling tube and discharges through the exhaust tube.Su- test FACP station perDuct air sampling tubes must be installed with the inlet holes facing the airstream.Sampling tubes may be rotated in 45-degree increments so that air-holes can be aligned to allow the unit to be SuperDuct detectors continually sample air flow in the HVAC duct mounted in virtually any angle relative to the airflow. and initiate an alarm condition whenever smoke is detected. An SuperDuct sensors are engineered to operate optimally under the alarm is activated when the quantity(percent obscuration)of harsh environmental conditions frequently found in HVAC duc- combustion products in that air sample exceeds the detector's twork. Nonetheless, before installing the detector,test the duct sensitivity setting. air velocity,temperature,and humidity to verify that it is within the operating range of the SuperDuct detector. Consult the SuperDuct Signature Series Intelligence installation sheet for details. Like all Signature detectors,the SIGA-SD features electronic addressing and issues a dirty sensor warning when it reaches its Dimensions preset limit.The dirty sensor warning indicates the sensor is op- erating within its specified limits but is in need of servicing.When - 8.70 in(22.1 cm) ) the detector's ability to compensate for environmental changes 7.75mi19.7cm has reached its limit,the duct smoke detector signals a trouble 3.08 in(7.82 cm) 41.60 in condition. The SIGA-SD also uses differential sensing to prevent gradual ' r environmental changes from triggering unwanted alarms.A rapid change in environmental conditions,such as smoke from a fire, • • e causes the detector to signal an alarm state, but dust and debris accumulated over time does not change alarm sensitivity. i 1 _ _ 1 i Each Signature Series SuperDuct detector contains a microproc- t$ 1' essor that performs comprehensive self-diagnostics and stores the results in nonvolatile memory. Stored results include details 2.28in such as hours of operation,last maintenance date,and number 578cm' of alarms and troubles.This information can be retrieved and z reviewed when desired. *... .-ij ' Detector Configuration 5.45 in The detector assembly cover provides easy access to the smoke "384 "9 sensor,its wiring connections,sample and exhaust tubes,and the < ' smoke chamber itself. 0 0 0 0 Air enters the detector's sensing chamber through a sampling .. - i1 tube(ordered separately)that extends into the duct and is directed I� back into the ventilation system through an exhaust tube(in- 1.90 in (4.83 an) eluded).The difference in air pressure between the two tubes pulls the sampled air through the sensing chamber.When a sufficient Y amount of smoke is detected in the sensing chamber,the detector b initiates an alarm. 1.38 in S40 in 4(3.51 cm) (1172 an) Page 2 of 4 DATA S H E E 1 85001-0584 Not to be used for installation purpose... Issue 6 1 Assembly High-humidity environments Sampling tube Detector socket Use the SD-PH Protective Housing when installing SuperDuct Exhaust tube _ .�- detectors in high-humidity environments.The SD-PH is a weather- socket + ized housing that prevents condensation on the device by insulat- j ` \\� ing the detectors and providing circulated air from the monitored tt HVAC duct.The SD-PH also adds a layer of protection against 1 , physical damage to the unit. Exhaust tube - I 11 + 1 Thin 440 gasket f )� Thick ��� gasket �I�� / 1 Coupling 11 �1 / Duct Detector SD-PH Sampling tube Protective (ordered separately) Housing ' p( O Plug :. 1'-Mounting ') = - Rear View HVAC duct �. Airflow . 1/ 1/ U(n a Hinged � ' ` Detector Cover 0 Silt Housing ..\.� �® - �' . air tube NNNN N\ �."` . Housing Detector `\ j i air tube conduit holes Sampling If D tube Nl -,....... il ,:,>% The SD-PH is easy to install and service.The hinged and transpar- o ent cover provides ready access to the detector,while keeping its f status indicators visible at all times. #10 sheet metal screw(2X) Note: The SD-PH Protective Housing is weatherized against out- door air, but it is not intended for direct outdoor exposure. Wiring Auxiliary equipment CW SIGA-LED[1] [1] No more than one remote test station CO1 ®®® or LED indicator can be connected to of 17 16 157 the detector at the same time.Wiring i 17 16 15 is unsupervised.Maximum wire resistance is 10 ohms per wire. Mil Win D-TRM• [ Of © SD-TRM[1] 17 a 0 ■■ ,l . I O fl DataData OutOut((-+)) /,��'`�V � t(, \j Data In(+) ::::: J!,'�1 Data In(-) lli I-7Z I_ mall MMMMwimp/ • o O • 14 13 12 11 10 9 8 7 0 )0 Power indicator Alarm indicator Page3of4 DATA T 85001-0584 Not to be used for installation purpos., Issue 6 `A/ `'� Specifications, detector Specifications, test stations Y Y A R D S 8.70 x 5.45 x 1.90 inches Remote Test/Reset Stations provide alarm test,trouble Dimensions (221 x 138 x 48 mm) indication,and reset capability from a remote loca- tion.They include a one-gang plate,momentary SPST Wire size 14 to 22 AWG switch,red alarm LED,and terminal block.Magnetically- Contact us... Detection Photoelectric operated models(TRM)or key-operated models(TRh method (light scattering principle) dre dvaildble. North American 1-gang box Email: edwards.fire©fs.utc.com 100 to 4,000 ft/min and Compatible Standard 4-in squarebox, Web: www.est-fire.com Air velocity electrical ratin meets the required minimum 1-1/2 inches deep,with EST is an EDWARDS brand. 9 air pressure differential boxes 1-gang cover 1016 Corporate Park Drive Air pressure 0.005 to 1.00 inches of LED indicators Alarm(red) Mebane,NC 27302 differential water LED type Clear lens In Canada,contact Chubb Edwards... Sensitivity 0.79 to 2.46%/ft Wire size 14 to 22 AWG Email: inquiries@chubbedwards.com obscuration Resistance per Web: www.chubbedwards.com Alarm test 5 seconds wire 10 Ohms,max. ©2013 UTC Fire&Security Americas response time Current Corporation,Inc.All rights reserved. _LED indicators Alarm(red),Power(green) requirements See controller specifications Specifications subject to change Unsupervised and power- LED circuit Voltage:3 Vdc,max. without notice.Edwards is part of UTC limited Climate,Controls&Security,a unit of ratings Current:30 mA,max. Common Quantity: 1 United Technologies Corporation. Switch ratings Voltage:125 Vdc,max. alarm relay Type:Form C (SD-TRK) Current:4 A,max. Ratings:2.0 A at 30 Vdc Switch ratings Voltage:200 Vdc,max. (resistive) (SD-TRM) Current:0.5 A,max. Operating 15.2 to 19.95 Vdc SuperDuct conventional voltage _ - Compatible two-wire and Signature duct Operating Standby:45 pA Alarm:45 detectors smoke detectors current pA Inrush:1 mA Standalone alarm:18 mA Operating -4°F to 158°F(-20°C to Temperature(UL):-4 to 158 environment 70°C)Humidity:93%RH, °F(-29 to 70°C). noncondensing Operating Temperature(ULC):-4 to Storage -4 to 140°F(-20 to 60°C) environment 120°F(-29 to 49°C) temperature Relative humidity:10 to Agency listings UL,ULC,MEA,CSFM 93%,noncondensing Agency UL,ULC,CSFM,FM,MEA listings Ordering Information Catalog Number Description Ship Wt.,lb.(kg) ----- SIGA-SD Intelligent SuperDuct Detector 2.4(1.1) Accessories SD-T8 8-inch sampling tube 0.5(0.2) SO-T18 18-inch sampling tube 1.5(0.7) SD-T24 24-inch sampling tube _ 2.7(1.2) SD-T36 36-inch sampling tube 3.0(1.4) SD-T42 42-inch sampling tube 3.5(1.6) SD-T60 60-inch sampling tube 5.8(2.6) SD-T78 78-inch sampling tube 7.5(3.4) SD-T120 120-inch sampling tube 11.5(5.2) SD-PH - Protective housing for high humidity environments 5.5(2.5) _ SIGA-LED Remote alarm LED 1.0(0.5) SD-TRM Remote test station,magnetic 1.0(0.5) _____-> SD-TRK Remote test station,keyed 1.0(0.5) SD-VTK Air velocity test kit(stoppers only,etc) 1.0(0.5) SD-GSK Cover gasket kit 0.5(0.2) SD-MAG Test magnet kit 0.5(0.2) SIGA-SDPCB Replacement PCB/Signature sensor kit 1.0(0.5) a Page 4 of 4 DATA SHE. - 85001-0584 J Not to be used for installation purpose:,. Issue6 EDWARDS®Catalog►Strobes,Horns,Bells,Chimes cgt3WAR D LIFE SAFETY ' INCIDENT MANAGEMENT LED . w�. ' � Genesis 1 GC Series _X ,. . . • . . . . . . . . Ceiling Mount • • • • • • • • • Notification Devices fi kt. 1 ;;.;.;.;;•;• I J •••:i•.i•i.• iw„ C®IJS S218, !.`- S5389 ..w '' FC Mil Ii Overview Standard Features Genesis LED GC Series horns and LED strobes feature a sleek • High Performance LED Strobe Technology low profile design and energy-efficient technology that makes —Ultra low device current consumption allows: them less expensive to install and operate by reducing overhead. —More devices per circuit High performance LEDs require fewer power supplies, backup —Ability to use lower gauge wire power,and batteries.These new appliances are designed with, —Longer wire runs energy-efficiency, and life safety in mind. —Fewer booster power supplies Genesis LED GC Series uses high efficiency optics,combined —High efficiency optics with patented electronics,to deliver a highly controlled and —Selectable 15,30, 75, or 115 cd light output LED devices may be mixed with legacy Xenon strobes efficiently focused light distribution pattern in exchange for lower current requirements.Strobes feature field-selectable • Efficient Audible Output 15,30,75,or 115 cd light output. —Selectable high or low dB horn output —Selectable temporal or steady horn output Compared with Xenon-type strobes,Genesis LED GC Series —Improved audio frequency range for better wall penetration appliances need fewer power supplies and often smaller wire gauge,which lightens conduit requirements.They are also • Low-profile Design backwards compatible with legacy strobes,so there's no need to —Ultra-slim...protrudes about 1.5"from the mounting surface replace all your existing devices to upgrade to new LED technology. —Attractive appearance... no visible mounting screws In fact,GC strobes can be mixed on the same circuit and used in • Multiple"FIRE"Marking Options the same field of view as Xenon-based strobes.This makes Genesis —Order English, French,Spanish or no FIRE markings LED GC Series ideal for new installations and retrofits alike. —Change markings at any time with replaceable Field-configurable sound output levels provide the flexibility quick-swap covers modern life safety projects demand,while the Genesis LED • Easy to Install control protocol keeps multiple strobes on compatible NAC —Pre-install and pre-wire with convenient universal room circuits synchronized to well within NFPA 72 requirements. side wiring plate Serviceability is another area where GC Series appliances shine. — Check electrical continuity on room side wiring plate with The universal room side wiring plate allows for pre-installation included diagnostics check bar and electrical wiring as well as checking continuity with the —Diagnostics port streamlines device circuit testing included diagnostics check bar. GC Series devices can then be — Fits 1-gang, 2-gang, 4-inch octagon, and 4-inch square easily snapped into place with the confidence of knowing the electrical boxes wiring is correct.The innovative under-cover diagnostic test points — Optional red and white trim plates available provide easy access to device circuit testing while mounted. —Slide switches for field configuration —12 to 18 AWG in-out screw terminals for quick wiring Page 1 of 6 DATA SHEET E85001-1021 Not to be used for installation purposes. Issue 1.1 Application Genesis LED GC Series horns,strobes,and horn-strobes mount Strobes to any standard one-gang,two-gang,4-inch octagon,and 4-inch square electrical box.Matching optional GCT trim rings are available Genesis GC Series strobes are UL 1971-listed for use indoors to cover oversized openings.Optional color matched double-gang as ceiling-mounted public-mode notification appliances for the surface boxes are also available.Genesis LED GC series are listed to hearing impaired. Prevailing codes require strobes to be used be both wall mounted or ceiling mounted. where ambient noise conditions exceed 105 dBA(87 dBA in Canada),where occupants use hearing protection,and in areas I of public accommodation as defined in the Americans with (1)\ / Disabilities Act. Q Synchronization is important in order to avoid triggering seizures in people with photosensitive epilepsy.All Genesis strobes exceed VV- UL synchronization requirements(within 10 milliseconds over a "" v ' I two-hour period)when used with a synchronization source.See (2)\ I I the specifications table for a list of compatible sources. / —o Horns Genesis horn output reaches as high as 92 dBA and features an — _ I improved audio frequency range compared with other Genesis I — horns.This results in excellent sound penetration through walls and Ia clear warning of danger.Horn only models may be configured for (3) I IN either coded or non-coded notification appliance circuits.They can \ PR also also be set for high or low dBA output.This setting reduces horn 10 -' 41�o-- ''�' output by about 6 dBA. '�+:,:-_.__���I�� I The suggested sound pressure level for each signaling zone used (4)\1 I with alarm signals is at least 15 dBA above the average ambient sound level,or 5 dBA above the maximum sound level having a (5)\ 1111111111.11111111111114 duration of at least 60 seconds,whichever is greater.These values are measured at five feet(1.5 m)above the floor.The average ��� jj=� ambient sound level is A-weighted,fast response sound pressure \��'`o%J,jL� measured over a 24-hour period. 1J ��--,�/� •, Doubling the distance from the signal to the ear will theoretically \` ��••• result in a 6 dBA reduction of the received sound pressure level. (1)Electrical Box ptional) The actual effect depends on the acoustic environment in the space. (3)WiringTrim Plateplate(required,(required,ordered separately) A 3 dBA difference represents a barely noticeable change in volume. (4)Machine screw(2x,supplied with wiring plate) (5)GC signaling appliance Installation Genesis GC horns and strobes mount to the required GP10 room side wiring plate.The GP10 mounting plate is ordered separately Wiring from the GC device in packs of 10 for convenient pre-installing and pre-wiring.The device can be removed easily from the room side wiring plate by pushing up with a screwdriver.The cover can also ` 144 0 0 0 be removed from the device easily with a screwdriver to access the 0 O light and sound output settings and a diagnostics test port for voltage testing. 0 0 Horn/strobe circuit in + 1 � 1 ♦Horn/strobe si nal polarity - circuit out Removing Cover Removing Device (i9 I sir,4l„loioioi shown in the ++�I q)I MI<I),I0101DI G7 .........., active condition) - �'�ii]Sl! (' 4--Shorting Shorting Cli II/i Id 11 l �, LO:113 I I IR�� cp f����� -�� I VW I"t ‘ LVNI MP/ : (2)0 I �j Page2of6 DATA SHEET E85001-1021 Not to be used for installation purposes. Issue 1.1 Dimensions Field Configuration GC Notification Appliances Temporal horn and horn-strobe models are factory set to sound in a three-pulse temporal pattern. By sliding the tone selector switch, t.e2 (4.62 cm) 6.8„ horn only models may be configured for constant horn output that 1- (17.27 cm) can be coded at precise intervals by EDWARDS control panels and control modules. \ � „ Note:Temporal 3 coding is the required output for fire notification devices per NFPA 72.Any device coding other than temporal Aii 3 is at the discretion and approval of the local authority having _ ', (7-101k\ jurisdiction(AHJ). o°00000 °` 1�;1�1 N�' �•°o o 0.:�'.'o°o°�� fI Horns and horn-strobes are factory set for high dB output. Low��j.: 0 0 0'� :•o°o e" dB output may be selected by sliding the tone selector switch. HMVI(f I% °o°o ! °o°° This reduces the output byabout 6 dBA. ,',�o°o°o°o o°o°o°o, .1 P 000000000,___ ® Genesis LED clear strobes and horn-strobes may be set for 15, I!: I 30, 75,or 115 candela output.The output setting is changed by / simply removing the cover and sliding the candela switch to the ��1 desired setting.The device does not have to be removed from the wall to change the output setting.The setting remains visible through a small window on the device after the cover is closed. GCT Trim Plate(optional) Light and Sound Output Settings 0.3" (26.92 cm) ,Aii ST/ ralL„ IGH /1 (2) ,„_, -1-.. OW (3) IGH (4) 000 0 0°Q 41*(..* CY-7 07....'''''"/': 11r. . 11.4.tor 4›, I (1)Constant,low dB l� �� y+ �d1 (6) (2)Constant,high dB p [ a ' IQ� (3)T3 temporal,low dB ui��\ �� i '9i (7) (4)T3 temporal,high dB ������� „ (8) 1 (5)115 candela \IL _�_____ ,7 (6)75 candela ���A:�� 4 (7)30 candela (8)15 candela Diagnostics Operating current r �►r Horns Strobes '/��•�►����•N. / I • \, Sound 16 to 33 16 to 33 Strobe 16 to 33 16 to 33 ���%,� l setting VDC VFWR setting VDC VFWR • �,�,� O I�// T- Low, 15,30, \���� �/� T Low 20 mA 25 mA 75, 115 35 mA 45 mA ���, i.r/ / 4 / C High, ���� ����✓ i 30 mA 40 mA ��: �j T High 57 o® o Horn-Strobes Test points indicated ( •• j Strobe above are used to validate "..1 �S setting Sound setting 16 to 33 VDC 16 to 33 VFWR the Notification Appliance 15,30, C Low,T-Low 50 mA 60 mA Circuit and verify device function. 75, 115 C High,T High E0 mA 75 mA ___. Page 3of6 DATA SHEET E85001-1021 Not to be used for installation purposes. Issue 1.1 Sound Output Light Distribution Horn&Horn-Strobe Horizontal Left io ° 5 10 Horizontal Right Sound setting Reverberant Anechoic 30 25 20 15 15 20 25 30 (UL464) (CAN/ULC-5925) 35 35 C-Low,T-Low 80 dBA 86 dBA 40 II r 40 C-High,T-High 86 dBA 92 dBA so45 1 4 55° 55 t�.►�': .�� � 55 60 80 705 ,�� ��,��'� 670 Sound pattern-Horn Models(ULC) ao 75 1111111Ir �` Slit: ;'r 7 0 85 `�- i.���� 85 Axis Angle(°) Output(dBA) 90 r =�� ~ � � 90 Horizontal 115 and 55 93.3 85 !�! <,$"1,1, 85 Vertical 125 and 50 91.7 e� f ~`virago 50 ��� 70 �-75 '�lig .1//1 �� 11111111, 75 70 65 60 �t 19 60 5 5 iitSound pattern—Horn-Strobe Models(ULC) 50� fi ., 1 it1 55 50 Axis Angle(°) Output(dBA) 45 a� t�1i tt,` *35 40 35 45 _ ._.._ 35 Horizontal 145 and 35 93.0 30 2 gil5 20 �l,, 20 25 30 155 and 35 90.8 15 10 5 5 10 15 135 and 35 92.0 o Vertical Bottom Vertical 155 and 25 85.4 Measured UL Minumum Specifications Operating voltage 16 to 33 VDC,16 to 33 VFWR Horn signal type Constant or TC3 temporal Light output 15,30,75,or 115 candela Strobe flash rate 1 fps(flash per second)approx. Synchronization 20 0 max.between any two devices.To determine allowed wire resistance,refer to these specifications,and the specifications for the synchronized signal source. Synchronization Sources Edwards CC Series Signal Modules,Booster and Auxiliary Power Supplies, Intelligent and Conventional Control Panels Wire size 12 to 18 AWG(0.75 to 2.50 mm2) _ Mounting Wall or Ceiling mount Dimensions(0 x D) 6.8 x 1.82 in.(17.27 x 4.62 cm) Strobe-to-box center offset -1.70 inches(-4.32 cm) Compatible electrical boxes[1] 1-gang,2-gang,4-inch octagon,4-inch square Trim plates GCTR,GCTW 10.6 x 0.3 in.(26.92 x 0.76 cm) Operating environment Temperature 32 to 122°F(0 to 50°C) Relative humidity 0 to 93%noncondensing Storage Temperature -40 to 158 F(-40 to 70 C) [1]Electrical boxes must be at least 1-1/2 in.(3.81 cm)deep. Page 4 of 6 DATA SHEET E85001-1021 Not to be used for installation purposes. Issue 1.1 Ordering Information Notification Appliances Color Marking Replacement Appliance Covers Color Marking GCARF Red FIRE GCARA-CVR Red ALERT GCARF FR Red FEU GCARF-CVR Red FIRE GCARF-FR-CVR Red FEU 0 GCARF-SP Red FUEGO GCARF SP CVR Red FUEGO GCARN Red None GCARN-CVR Red None GCAWF White FIRE GCAWA-CVR White ALERT Horns GCAWF-FR White FEU HornGCAWF CVR White FIRE Covers ' GCAWF-FR-CVR White FEU GCAWF-SP White FUEGO GCAWF-SP-CVR White FUEGO GCAWN White None GCAWN-CVR White None a r, x,.: GCVRF Red FIRE GOVRA CVR Red ALERT pis` ,.' GCVRF-FR Red FEU GCVRF-CVR Red FIRE GCVRF SP Red FUEGO ,F�m GCVRF-FR-CVR Red FEU GCVRF-SP-CVR Red FUEGO 'i -' ,, GCVRN Red NoneII 111GCVRN-CVR Red None NZ GCAWF White FIRE � GCVWA-CVR White ALERT 8trbbes GCVWF-FR White FEU Strobe GCVWF-CVR White FIRE GCVWF-SP White FUEGO Covers GCVWF-FR-CVR White FEU GCWN White None GCVWF-SP-CVR White FUEGO GCVWN-CVR White None GCAVRF Red FIRE GCAVRF-FR Red FEU GCAVRA-CVR Red ALERT GCAVRF-CVR Red FIRE GCAVRF-SP Red FUEGO GCAVRF-FR-CVR Red FEU `R,- GCAVRN Red None GCAVRF-SP-CVR Red FUEGO GCAWF White FIRE , ':: GCAVRN-CVR Red None Horn-streGes GCAVWF-FR White FEU GCAVWA CVR White ALERT Horn-strobe GCAVWF-CVR White FIRE GCAVWF-SP White FUEGO Covers GCAVWF-FR-CVR White FEU GCAWN White None GCAVWF-SP-CVR White FUEGO GCAVWN-CVR White None Accessories MI Room Side Wiring Trim plate,GC Series, Trim plate,GC Series, GP10 Plate(required, 0GCTR red GCTW white �J. ordered separately) / ' 27193-21 Two-gang surface mount box,red 27193-26 Two-gang surface mount box,white Model Number Syntax, Appliances Model Number Syntax, Replacement Covers Genesis Series GC=Ceiling mount appliances Genesis Series GC=Ceiling mount appliances Housing Color R=Red Housing Color W=White R=Red W=White GCAVRF Housing Marking I 1 Cover t I N=None ALERT Marking GCAVRF-CVR Designation LF-FR=FEU available on white F-SP=FUEGO strobe model only. Cover Marking Functions F=FIRE See replacement N=None A=Horn only A=ALERT* covers for more Functions F-FR=FEU V=Strobe only options. A=Horn only F-SP=FUEGO AV=Horn-Strobe V=Strobe only F=FIRE AV=Horn-Strobe A=ALERT Page5of6 DATA SHEET E85001-1021 Not to be used for installation purposes. Issue 1.1 • cE-DWARDS LIFE SAFETY&INCIDENT MANAGEMENT Contact us Phone: 800-655-4497(Option 4) Email: edwardsfire@carrier.com Website: edwardsfiresafetv.com 8985 Town Center Pkwy Bradenton,FL 34202 ©2020 Carrier All rights reserved. Page6of6 DATA SHEET E85001-1021 Not to be used for installation purposes. Issue 1.1 F�� f DURACELL SLA Batteries � ir � ULTRA Duracell' Ultra SLA technology offers high-density power that out- performs traditional lead acid batteries.The Absorbed Glass Mat (AGM) ""* " construction is designed for efficient gas recombination and allows for 1116613111111 Allillilltw maintenance-free operation. Duracell®Ultra SLA batteries maintain their high capacity with a design that is resistant to damage caused by deep discharge. Every Duracell® Ultra SLA � battery is inspected to ensure i. r ' ' the highest standards in materials and fabrication. ,, u e-150 yces at 100% Discharge „.: nunAl2-•F RY uoEncro .....gu°°' �a ��' SEALEO 40N SGIlEABIE eATTE DURACELL SPILL ULTRA i➢D)}4T)1�SHD))})S4At 7 PROOF �- �- ����r. ,t,✓,- GUARANTEE Features: • Duracell® Ultra SLA GEL batteries contain a proprietary grid alloy formula combined with advanced plate curing techniques to provide maximum performance. • Duracell® Ultra batteries contain a unique electrolyte formula with a special sub-colloid additive for higher reliability and longer life. • Will achieve more life cycles than standard AGM and Deep Cycle batteries. • The unique construction and sealing techniques of these batteries t I:rlii27aCEi 3 are guaranteed to give you leak-proof operation. _:< ULTRA • Heavy-duty lead calcium tin alloy grids provide an extra margin of performance l and service life in cyclic applications, even after repeated over-discharges. • Quality Assurance Engineers monitor and control the entire production process. • Recycling of used SLA batteries available. CASE ,__ -' • Delivery available. ,,- Quantities DD� ®L�... . AVAILABLE ❑D JD Sealed 1 Lead YEAR ,� Acid Maintenance Free Spill Proof 1 Year Stringent Quality Design Warranty Control 'r,t, g , r'1r"" ; 'ER batteriesplus.com 1-800-677-8278 PROJECT DURACELL SLA Batteries CATALOG#AME_ ULTRA FIXTURE TYPE NOTES ,'1,1*,,, tt p'ej?ihff'€i Battery ;'' ''11ts Capacity Ah, 'r.) Dimensions(LxWxH In't r Terminal r DURA12-0.8WL 12V 0.8 3.78 0.98 2.4 VVL El 0.77 DURA12-1.3F 12V 1.3 3.82 1.69 2.28 F1,T1 1.37 DURA12-2.3F 12V 2.3 6.91 1.38 2.64 F1,T1 2.04 DURA12-2.9F 12V 2.9 3.11 2.2 3.9 F1,T1 2.36 DURA12-3.3F 12V 3.3 5.28 2.64 2.63 F1,T1 - 3.18 DURA12-3.3F2 12V 3.3 - - - - - RAYA12-4F 12V 4 3.54 2.76 4.21 F1,T1 DURA12-5F 12V 5 3.54 2.76 4.21 F1,T1 - - DURA12-5F2 12V 5 3.56 2.77 3.94 F2,T2 - DURA12-5.1A 12V 5.1 5.51 1.89 4.21 F1,T1 4.6 DURA12-5.5F 12V 5.5 3.54 2.76 3.98 - - RAYA12-7F 12V 7 5.95 2.56 3.94 F1,T1 - DURA12-7F 12V 7 5.94 2.56 3.94 F1,T1 - DURA12-7F2 12V 7 5.94 2.56 3.7 F2,T2 - DURA12-8F 12V 8 5.94 2.56 3.94 F1,T1 - DURA12-8F2 12V 8 5.94 2.56 3.94 F2,T2 IIIIII - DURA12-9NB 12V 9 5.95 2.56 3.9 NB J DURA12-9F2 12V 9 5.95 2.56 1 3.94 F2,T2 - DURA12-10F2 12V 10 5.95 2.54 4.38 F2,T2 7.5 DURA12-11NB 12V 11 5.28 3.15 6.5 - 10.1 DURA12-12F2 12V 12 5.94 3.9 3.98 F2,T2 • DURA12-12F 12V 12 5.94 3.86 3.86 F1,T1 - DURA12-14F2 12V 14 5.94 3.86 3.98 F2,T2 - 8.91 DURA12-18F2 12V 18 7.13 3.03 6.57 F2,T2 - - DURA12-18NB 12V 18 7.13 3.03 6.57 NB,1 • 12.43 DURA12-26NB 12V 26 6.5 6.93 4.92 NB,J - 20.7 DURA12-35C 12V 35 7.72 5.16 6.5 C - 27.3 DURA12-44C/FR 12V 46 7.8 6.54 6.85 C - 38 DURA12-55C/FR 12V 55 9.02 5.43 r 8.35 - - 42.1 DURA12-80C/FR 12V 80 10.24 6.65 8.46 C - - DURA12.100C/FR 12V 100 12.09 6.65 8.46 C - 74.6 DURA12-140C/FR 12V 140 13.43 6.81 11.3 C - 108 DURA4-4.5F2 4V 4.5 1.85 1.85 3.98 F2,T2 - 1.4 DURA6-1.3F 6V 1.3 3.82 0.94 2.28 F1,T1 - 0.715 DURA6-25T 6V 2 1.69 1.45 2.99 ST - 0.75 DURA6-2.9F 6V 2.9 2.6 1.46 3.82 F1,T1 1.26 DURA6-3.3F 6V 3.3 5.28 1.34 2.64 F1,T1 1.65 RAYA6-4F 6V 4 2.76 1.85 4.13 F1,T1 - DURA6-SSP 6V 5 2.6 2.6 4.53 SP 2.09 DURA6-5F 6V 5 2.76 1.85 4.21 FIX - DURA6-7.2F 6V 7.2 5.94 1.34 3.68 F1,T1 2.43 DURA6-8.2F 6V 8.2 - 3.9 2.24 4.53 - F1,Tl, 3.8 DURA6-10F 6V 10 5.94 1.97 3.98 F1,T1 4.851 DURA6-12F 6V 12 5.94 1.97 3.98 F1,T1 - DURA6-12F2 6V 12 5.94 1.97 3.98 F2,T2 4.602 RAYA6-14T2 6V 14 4.25 2.8 5.51 H 6.24 DURA6-14A 6V 14 4.25 2.8 5.51 F1(-)F2(+),T1(-)T2(+),FP - 6.16 DURA6-42F2 6V 42 6.25 3.37 6.37 F2,T2 - 16.64 DURA6-42NB 6V 42 6.34 3.43 6.42 NB,J - 16.62 DURA6-200C 6V 200 12.05 6.65 8.63 C - - DURA8-3.2F 8V 3.2 5.28 1.44 2.48 F1,T1 - 1.65 Visit batteriesplus.com for warranty information Batteries- Bulbs 0 2017 DURACELL,Bethel,a06801.Duracell is a registered trademark of Duracell U.S.Operations,Inc.,used under license.All rights reserved. * rend' .I r o � ` Cg, / : SAE 10 — FDB FIRE ALARM DOCUMENTS BOX FIRE ALARM SDI Fire has you covered when it comes to your fire protection accessories.Our Q,�r�LI !1/ S Fire Alarm Documents Box is top of the line. ilrf ii�� rams • CAT 30 secured locking door Manuals a9 Recoro • Door with notes sticker • Removable document holder • Embossed: —Key ring hooks —Business card holder —CD case slot • Space for can of detector test gas