Loading...
Permit CITY OF TIGARD MASTER PERMIT I COMMUNITY DEVELOPMENT Permit MASTER MST2021-00325 T(f;A FtD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 08/19/2021 Parcel: 2S103CB11000 Jurisdiction: Tigard Site address: 12177 SW QUAIL CREEK LN Subdivision: QUAIL HOLLOW-EAST Lot: 68 Project: Crisman Project Description: Rooftop Solar PV 11.625 kW BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $10,492.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Bckflw Prevntr: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: Y Other Description: Roof Top Solar PV System 11.625 kW Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: CRISMAN,DAVID G&CHRISTINE N BRS FIELD OPS LLC Required Items and Reports(Conditions) 12177 SW QUAIL CREEK LN 1403 NORTH RESEARCH WAY TIGARD,OR 97223 OREM,UT 84097 PHONE: PHONE: 855-205-2530 FAX: Total Fees: $361.19 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law r •uires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR oc9-nn1-M1n thrn,inh rl rig-nnl- .on 0,,n,w obtain nn+,of thy- !lac nr dirt nnactinnc to!ll IMC by rnllinn Sell9'19 10R7 nr'I Rnn 119 94dd - �'• Ira Issued By: fi//� io�i��� r Permittee Signature: �� �p�i / r Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. , Building Permit Application Aa•-• et i ti Z j Residential RECEIVED FOR OFFICE;USE ONLY City of Tigard AUG 101�21 0 /B D� /L zol '��� Permit No.:kiS 20ZI—QV 32G 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review ` ' Phone: 503.718.2439 Fax: 503.598.1960. 7nA Date/By: L 7/I Other Permit: Inspection Line: 503.639.4175 "� OF I(t�1'1RV Date Ready/By: J H See Page 2 for t `��i�`' www.tigard-or.gov 3UILDING DIVISION pp Internet: www.ti ard-or. ov N '�ed/Method: ��' Supplemental Information TYPE OF WORK 2ED ATA:1-AND 2-FAMILY DWELLING ❑New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ty� a Di_and 2-family dwelling 0 Commercial/industrialValuation: $ $10,492.59 ❑Accessory building El Multi-familyNumber of bedrooms: ❑Master builder ❑Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 12177 SW Quail Creek Ln,Tigard,Oregon,97223 New dwelling area: square feet City/State/ZIP: Garage/carport area: square feet Suite/bldg./apt.no.: Project name: David Crisman Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Rooftop Solar PV Valuation: $ 1 `t ('7 c Existing building area: square feet v New building area: square feet ® PROPERTY OWNER ❑ TENANT Number of stories: Name: David Crisman Type of construction: Address: 12177 SW Quail Creek Ln,Tigard,Oregon,97223 Occupancy groups: City/State/ZIP: Existing: Phone:( ) Fax:( ) New: 0 APPLICANT ED CONTACT PERSON BUILDING PERMIT FEES* Business name: BRS Field Ops, LLC (Please refer to fee schedule) Structural plan review fee(or deposit): Contact name: Jeffrey Lee Address: 1403 N Research Way FLS plan review fee(if applicable): City/State/ZIP: Orem, UT 84097 Total fees due upon application: Amount received: Phone:( 385)482-0045 Fax: :( ) E-mail: permitting.deparment@blueravensolar.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System. Business name: BRS Field Ops, LLC Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address: 1403 N Research Way Solar Installation Specialty Code checklist. City/State/ZIP: Orem, UT 84097 Permit Fee(includes plan review $180.00 and administrative fees): Phone:( 385*82-0045 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lie.: 227185 Total fee due upon application: $201.60 Authorized signature: ,// This permit application expires if a permit is not obtained / j within 180 days after it has been accepted as complete. Print name: Jeffrey ee Date: 08/02/2021 *Fee methodology set by Tri-County Building Industry Service Board. I:'Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) Electrical Permit ApplicatiolECEtVE , POR OFFICE ['SF OyLv �' Received City of Tigard Date/By: Permit#:HST2021-Oo325 M 13125 SW Hall Blvd.,Tigard,OR 97223 - C, ,in p1114 Plan Review Phone: 503.718.2439 Fax: 503.598.1960 AUG Date/By: Related Permit#: Inspection Line: 503.639.4175 Ready Date/By: Juris: 2 ' '"I` Internet: www.tigard-or.gov ,;I I Y OF TIGAKLI Notified/Method: S See Pent l Information TYPE OF W( ,t l , i,":—,:, ;'t.' ; , «�R., PLAN REVIEW 0 New construction t51 Addition/alteration/replacerneni Please check all that apply(submit 2 sets of plans w/items checked). ❑Service or feeder 400 amps or more 0 Building over three stories. ❑Demolition ❑Other: where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings. EN 1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural amps for all other installations. buildings. 0 Multi family 0 Master builder ❑Other: 0 Fire o pump. 0 Installation of 150 KVA or ' jQ$,$I1 ' * ' QN ",1OPlj 0 Emergency system. larger separately derived ❑Addition of new motor load of system. Job#: Job site address: 12177 SW Quail Creek Ln,Tigard,Oregon,97223 100HP or more. ❑"A","E","t-2","1-3", ❑Six or more residential units. occupancy. City/State/ZIP: ❑Recreational vehicle 0 Health-care facilities. parks. Suite/bldg./apt.#: Project name: David Crisman 0 Hazardous locations. 0 Supply voltage for more than 0 Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: FEE SCHEDULE Description I Qty. I Each I Total I * New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. Tax map/parcel#: 1,000 sq.ft.or less 168.54 4 Ea.add'l 500 sq.ft.or portion 33.92 1 DESCRIPTION OF WORK Limited energy,residential 75.00 2 Rooftop Solar PV (with above sq.ft.) Limited energy,multi-family 75.00 2 residential(with above sq.ft.) Renewable Energy 0 See Page 2 Ear PROPERTY OWNER 0 TENANT Services or feeders installation,alteration,and/or relocation Name: David Crisman 200 amps or less 100.70 2 Address: 12177 SW Quail Creek Ln,Tigard,Oregon,97223 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP: 601 amps to 1,000 amps 301.04 2 Phone:( ) Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 APPLICANT Branch circuits—new,alteration,or extension,per panel ❑ CONTACT PERSON A.Fee for branch circuits with Business name: BRS Field Ops, LLC above service or feeder fee, 7.42 2 each branch circuit Contact name: Jeffrey Lee B.Fee for branch circuits without Address: 1403 N Research Way service or feeder fee,first 56.18 2 branch circuit City/State/ZIP: Orem, UT 84097 Each add'l branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone: ( 385 482-0045 Fax: :( ) Each manufactured or modular 67.84 2 Email: permitting.department@blueravensolar.com dwelling,service and/or feeder Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name: BRS Field Ops, LLC Sign or outline lighting 67.84 2 Signal circuit(s)or limited-energy Address: 1403 N Research Way panel,alteration,or extension. 0 See Page 2 2 City/State/ZIP: Orem, UT 84097 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone:( 385)182-0045 Fax:( ) Investigation(1 hr min) 90.00/hr Email: permitting.department@blueravensolar.com Industnal plant(1 hr min) 78.18/hr Inspections for which no fee is CCB Lic.: 227185 Electrical Lc.: C 1493 ; Suprv.Lic.: 6394S specifically listed(1/2hr min) 90.00/hr Suprv.Electrician signature,required: 762ELECTRICAL PERMIT FEESSubtotal: Print name: Shan Whittaker Date: 08/02/2021 0 Plan Review Required(25%of permit fee): , State surcharge(12%of permit fee): Authorized signature: i// TOTAL PERMIT FEE:expires permit application expires if a permit is not obtained within 180 Print name: Jeffrey L Date: 08/02/2021 days after it has been accepted as complete. * Number of inspections allowed per permit. l:\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015 440-4615T(I 1/05/COM/WEB Electrical Permit Application-City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY: Description gee Total Fee for all residential systems combined: $75.00 Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 1 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 1111 Garage Door Opener* >100 kva(fee in accordance with OAR 918-309-0040) 552.26 2 ❑ Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva-no additional charge 0.0 3 Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspection is charged at an hourly(1 hr min) 66.25/hr Inspections for which no fee is 90.00/hr specifically listed(t/z hr min) tt, t 4.ECM WORk ONLY: ELECTRICAL PERMIT FEES Fee for each commercial system: $75.00 Subtotal(Enter on Page 1): * Number of inspections allowed per permit. (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ A• udio and Stereo Systems ❑ Boiler Controls ❑ C• lock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems n L• andscape Irrigation Control* ❑ Medical n N• urse Calls n O• utdoor Landscape Lighting* n Protective Signaling ❑ O• ther: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I1BuildingPermits\ELC_PennitApp_ELR_ERE.doc Rev 06/17/2015 _ w - City of Tigard RECEIVED II IN Building Division AUG 10 202! 13125 SW Hall Blvd,Tigard, OR 97223 CITY OF TIGARU Phone: 503.718.2439 Fax: 503.598.1960 BUILDING DIVISION T I G A R D Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 12177 SW Quail Creek Ln, Tigard, Oregon, 97223 City: Zip: Owner's Name: David Crisman Date: 08/02/2021 Contractor's Name: BRS Field Ops, LLC CCB #: 227185 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation El Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? p No OSSC or ORSC for design requirements. Wind Exposure Is the wind exposure 0 Yes If"Yes", qualifies for "C" or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes 0 Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than If"Yes", qualifies for 0 Yes the prescriptive path. above ❑ No 1 I1Building/Forms/PhotoVoltaic-Checklist02-01-11.docx Is the construction MI material wood and does Yes Type of If"Yes", qualifies for the construction qualify Construction No the prescriptive path. as "conventional light ❑ frame" construction? Is the spacing 24 inches or less? If"Yes", qualifies for Pre-engineered trusses. 0 Yes the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. 0 If"Yes", qualifies for Yes the prescriptive path. ❑ No Is the combined weight p Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation MI layout in accordance Yes with Section 305.4(3) of If"Yes", qualifies for the 2010 Oregon Solar ❑ No the prescriptive path. Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. C7 of composition shingle. Is the roof mounted p Yes Connections of solar assembly If"Yes", qualifies for the solar assembly connected to roof ❑ No the prescriptive path. to the roof framing or blocking directly? 2 I:/Building/Forms/PhotoVoltaic-Checklist02-01-11.docx ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? ❑ If"Yes", qualifies for Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the prescriptive path. standing seam metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? ❑ Yes the prescriptive path. ❑ No Is the roof decking of WSP min. 1/2" thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof Yes the prescriptive path. surface. ❑ No 3 I:B uilding/Forms/Photo V oltaic-Checkli st02-01-11.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: JinKO Solar Eagle Model Number: JKM375M-6RL3-B Listing Agency: CSA 4 I:Building/Forms/Photo Voltaic-Checklist02-01-11.docx