Loading...
Specifications RECEIV Structural Calculations JUN 12 2071 CITY OF 1lur,d, • for BUILDING 1:11Vlc' , ) Residential Repair at sr,20.v-aoz8.? 15374 SW Thurston Ln Tigard, OR June 28, 2021 DESIGN CODE 2021 Oregon Residential Specialty Code DESIGN LOADS Gravity Loads Material Wt lbs (Dead) 25 psf (Live-Snow) PRop- OFFICE COPY ir,. G I NF\'/ ;, ° 92496PE 0 EGillartruL, any> < M.R. ' EXPIRES: 12/31/2022 SCOPE OF WORK The attached calculations pertain to the gravity analysis of framing repair at the above address. This scope of work does not include any analysis of any other portions of structure to remain. BY Sm DATE HAY E ENGINEERS REV DATE STRUCTURAL I CIVIL JOB NO 21196 (503)968-9994 p (503)968-8444 f SHEET 1 OF /3 HAYDEN Ei3( ENGINEERS STRUCTURAL I CIVIL Wood Beam Software thurston.ec6 Software copyright ENERCALC,INC.1983-2020,Build:12.20.8.17 Lie.#:KW-06005543 HAYDEN CONSULTING ENGINEERS DESCRIPTIO hip rafter CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019,ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Analysis Meth°Allowable Stress Design Fb+ 900.0 psi E:Modulus of Elasti Load CombinatiASCE 7-16 Fb- 900.0 psi Ebend-xx 1,600.0 ksi Fc-Prll 1,350.0 psi Eminbend-x 580.0 ksi Wood Species DouglasFir-Larch Fc-Perp 625.0 psi Wood Grade No.2 Fv 180.0 psi Ft 575.0psi Density 31.210pcf Beam Bracing Beam is Fully Braced against lateral-torsional buckling ry— - C?(0,0.0825)S(0,0.1375) 2x8 r ,--, I rah TI1'f1 Span=8.0 ft Applied Loads Service loads entered.Load Factors will be applied for calculations. Load for Span Number 1 Varying Uniform Load : D=0.0->0.0150, S=0.0->0.0250 ksf, Extent=0.0--»8.0 ft, Trib Width =5.50 ft DESIGN SUMMARY Design OK ;Maximum Bending Stress Ratio = 0.664: 1 Maximum Shear Stress Ratio = 0.308 : 1 Section used for this span 2x8 Section used for this span 2x8 fb:Actual = 824.83psi fv: Actual = 63.85 psi Fb:Allowable = 1.242.00psi Fv: Allowable = 207.00 psi Load Combination +D+S+H Load Combination +D+S+H Location of maximum on span = 4.613ft Location of maximum on span = 7.416 ft Span#where maximum occurs = Span# 1 Span#where maximum occurs = Span# 1 Maximum Deflection Max Downward Transient Deflection 0.084 in Ratio= 1 146>=360 Max Upward Transient Deflection 0.000 in Ratio= 0<360 y Max Downward Total Deflection 0.134 in Ratio= 716>=240 Max Upward Total Deflection 0.000 in Ratio= 0<240 Vertical Reactions Support notation:Far left is#' Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 0.183 0.367 Overall MINimum 0.183 0.367 D Only 0.110 0.220 S Only 0.183 0.367 2 /3 4, HAYDEN Ei3( ENGINEERS STRUCTURAL I CIVIL Wood Beam File:thurston.ec6 Software cop ight ENERCALC,INC.1983-2020,Build:12.20.8.17 Lie.# KW-06005543 HAYDEN CrNSULTING ENGINEERS DESCRIPTIO new edge beam CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019,ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Analysis MethoAllowable Stress Design Fb+ 875.0 psi E:Modulus of Elasti Load CombinatiASCE 7-16 Fb- 875.0 psi Ebend-xx 1,300.0ksi Fc-Prll 600.0 psi Eminbend-x 470.0 ksi Wood Species Douglas Fir-Larch Fc-Perp 625.0 psi Wood Grade No.2 Fv 170.0 psi Ft 425.0 psi Density 31.210 pcf Beam Bracing Beam is Fully Braced against lateral-torsional buckling D(0.04125,0)S(0.06875,0) D(0.03)S(0.05) b —�` a. b o b L v b 6x8 Span=21.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Load for Span Number 1 Uniform Load : D =0.0150, S =0.0250 ksf, Extent=0.0-->> 15.50 ft, Tributary Width =2.0 ft Varying Uniform Load : D=0.0150->0.0, S=0.0250->0.0 ksf, Extent= 15.50-->>21.0 ft, Trib Wid h = Wiin tolerance, OK DESIGN SUMMARY ......�...,.... Maximum Bending Stress Ratio = 003: 1 Maximum Shear Stress Ratio = 0.146 : 1 Section used for this span 6x8 Section used for this span 6x8 fb:Actual = 1,014.62psi fv: Actual = 28.59 psi Fb:Allowable = 1,006.25 psi Fv: Allowable = 195.50 psi Load Combination +D+S+H Load Combination +D+S+H Location of maximum on span = 10.423ft Location of maximum on span = 0.000ft Span#where maximum occurs = Span# 1 Span#where maximum occurs = Span# 1 Maximum Deflection Max Downward Transient Deflection 0.863 in Ratio= 292>=240 Max Upward Transient Deflection 0.000 in Ratio= 0<240 Max Downward Total Deflection 1.381 in Ratio= 182>=180 Max Upward Total Deflection 0.000 in Ratio= 0<180 - Vertical Reactions Support notation : Far left is# Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 0.522 0.442 Overall MINimum 0.522 0.442 D Only 0.313 0.265 S Only 0.522 0.442 3 /3