Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
1 C2o2/-'oVg 7 INLINE7511DOFFICE COPY OFFICE COPY COMMERCIAL CONSTRUCTION INC. SUBMITTAL TRANSMITTAL RECEIVED JUN 1 ':i 2021 Date: 4/15/21 CITY OF TIGARD BUILDING DIVISION Project Name and No.: TTSD 5 Mechanical Upgrades#8977-21 Engineer: Interface Engineering, Inc. To: Tigard-Tualatin School District Attn: Jesse Cavazos 6960 SW Sandburg Tigard, OR 97223 Phone: (210) 803-8253 From: Jeff Rule Phone: (503) 939-3430 Email: JeffRCa�inline-cc.com CC: Transmitted via: ❑ Mail ❑ UPS/FedEx ❑Courier ❑ Hand Delivery ®Other Email QTY DATE SUBMITTAL# DESCRIPTION 1 4/15/21 23.00.00.1 HVAC Product Data Transmitted as checked below: ® For signature/approval ❑ For your use ❑ As requested ❑Other COMMENTS: SHOP DRAWINGS AND PRODUCT DATA Please review at your earliest convenience. r REVIEWED I NGL Ir NQ E Submittal Review I—REVIEWED AS NOTED sn36 an, owner:rawo Interface Engineering,Inc. 100 SW Main Street,Suite 1600 Thank you! n REVISE AND RESUBMIT Portland,Oregon 97204 503-382-2266 Reviewed only for general conformance with the design concept of the "No Exception Taken"constitutes that review is for general conformance with the design Project and general compliance with the information given in the Contact concept expressed in the Contract Documents for the limited purpose of checking for Documents.The review does not affect the Subcontractors responsibility to conformance with information given.Any action shown below is subject to the Jeff Rule perform all contract requirements with no change in contract price or time. requirements of the Contract Documents. Contractor is responsible for the dimensions Any actions shown are subject to the requirements of the plans and and quantity which shall be confirmed and correlated at the job site,fabrication processes spedfioations.Subcontractor is responsible to confirm and correlate and techniques of construction,coordination of the work with that of all other trades,and dimensions on the site for Information that pertains solely to the fabrication the satisfactory performance of the work. processes for the means,methods,techniques.procedures.sequences and quantities necessary to complete the contract and for coordination of the 0 No exception taken. work with all trades and the satisfactory performance of work.Any review is XMake corrections noted. Resubmittal not required if installation complies with notes. undertaken solely to satisfy Contractor's obligations,ifany,to the Owner 0 Revise and Resubmit: and shall not give rise to any claim by Subcontractor or other parties against 0 Manufacturer not approved. Resubmit. Contractor,Architect or Owner. 0 Does not meet requirements of the Contract Documents. Returned without review. See comments and submittal requirements in the Specifications.Resubmit. 0 Forward specified item. Date:1 4/15/21 Jobs 18977-21 0 See attached Submittal Review Form. Date:04-28-2021 By: R.Silenzi-Interface Engineering Signed:Jeff Rule Submittal a 123.00.00.1 PO Box 5837/18880 SW Shaw St www.inline-cc.com Phone: 503-642-5117 Aloha, OR 97006 CCB#51880/MBE#714 Fax: 503-649-3301 Form Updated 12/2013 Submittal Transmittal Page 1 of 1 Apollo Mechanical Contractors 7555 SW Tech Center Drive Tigard,OR 97223 �E�lulvlc�L 503-222-6343 phone 4#1141 `""RA`."'"' 503-222-2935 fax ...Building Pimple Who Build Great Things WA Reg.No APOLLMC864JQ OR CCB No.56241 CO Plumbing Lic:PC.0301136 M t CRN:149670 CA Contractor License:1003129 An Equal Opportunity Employer I � Transmittal Letter To: Inline Commercial Construction Inc. Date: 04/14/21 Project: TTSD 5 Mechanical Upgrades Attn: Jeff Rule Reference: TTSD Mechanical Upgrade JeffR(li inline-cc.com Drawing Set We are sending you III Attached El Under Separate Cover via: ❑ Shop Drawings ❑ Prints Submittals ❑ Other: ❑ Copy of Letter ❑ Change Order 0 Samples ❑ Total Quantity ❑ Reproducible ❑ Specification These are transmitted as checked below For Approval ❑ Approved as Submitted ❑ Resubmit copies for approval ❑ For Your Use ❑ Approved as Noted ❑ Submit [#] copies for distribution ❑ As Requested, ❑ Returned for Corrections ❑ Return [#] corrected prints ❑ For Review and Comment ❑ Revise and Resubmit/Work May Not Proceed Description Please review and approve these products. Loose DX coils, condensing units, and roof top units. Thank You. Comments: These products have a very long 9-10 week delivery lead-time, after an order is placed. Because these products are basis of design, the vendor has carefully assembled this data to meet the specifications. Apollo asks that the design team return their review comments limited to either "Approved"or "Make Corrections Noted", without any resubmission due to construction time restraints. Thank you. Copy to: Soo a?&iEiamd Signature o4/14€16...Fade, Peoge 206t Eadd 9Aeat 74 09.1. An equal opportunity employer Condensing Units DURHAM j Eli o R E G o N Submittal Date: April 9th, 2021 Customer: Apollo Mechanical Project Name: TTSD- Durham ES Engineer: Interface 23 62 13 Packaged Air-Cooled Location: Tigard, OR Spec Section: Refrigerant Compressor and Condenser Units Johnson Barrow respectfully submits the following equipment for review: Product Tags Qty. Model Manufacturer ACU-1,5, & 6-J25YD; Air Cooled Condensing Units ACU-1 thru 8 7 ACU 2 & 3-J 15YC; JCI; ACU-7-TCD48; Guardian (ACU-7) ACU-8-J40YD General Notes: • This submittal is for approval. Approval is required in order for equipment to be released for fabrication Submitted By: Matt Donovan Anthony Tomasi Johnson Barrow Oregon Johnson Barrow Oregon Direct/Cell: - 503-688-0123 Direct/Cell:-503-320-9565 Email: MattD@JBarrow.com Email: AnthonyT@JBarrow.com Sign Date Approved as Noted Approved with Comments Revise and Re-submit 735 SW 20th Place 230 , Portland , OR 97205 PHONE (971) 717-7123 jBtio o R E G o N Submittal Contents Scope of Offer and Clarifications 3 Unit Performance 4 Unit Dimensional Drawing 15 Electrical Notes and Wiring Diagrams .25 Unit Written Specification 30 Warranty 36 735 SW 20th Place 230 , Portland , OR 97205 PHONE (971) 717-7123 OREGON Submittal Scope of Offer and Clarifications • (7) JCl/Guardian Air Cooled Condensing Units o R410A Refrigerant o Single circuit or dual circuit (See Attached Unit Selections) o Hot gas bypass kit (field installed by others) O 208V/3Ph/60Hz Single Point Power O 1-Year parts warranty O 5-Year compressor parts warranty Exclusions: • Any interconnecting refrigerant piping or specialties by others (TXVs, filter driers, etc.) • Any new drain pans by others (existing pans assumed to be reused or any new drain pans by others) • Offloading, storage, access, rigging, and installation by others • Concrete Pad, Vibration isolation or mounting equipment by others • Seismic calculations by others • Startup, commissioning and/or balancing by others • Any labor warranty not included 735 SW 20th Place 230 , Portland , OR 97205 PHONE (971) 717-7123 jaio o R EG © N Submittal Unit Performance 735 SW 20th Place 230 , Portland , OR 97205 PHONE (971) 717-7123 �1 I Outdoor Split System Johnson Controls Johnson Controls Split-System R-410A Outdoor Project Name: TTSD-Durham Unit Model#: J15YCCOOA2GAE4 Quantity: 2 Tag#:ACU-2&ACU-3 System: J15YCCOOA2GAE4 Cooling Performance Total gross capacity 160.2 MBH Sensible gross capacity ✓ .0 MBH •� Total net capacity 160.2 MBH Efficiency(at ARI) EER Ambient DB temp. 95.0 °F Power input(w/o blower) 13.36 kW Suction pressure 131 psig Saturated suction temp. 45 °F Refrigerant Refrigerant type R-410A Electrical Data Power supply 208-3-60 Unit min circuit ampacity ✓64.7 Amps Unit max over-current protection 80 Amps Dimensions&Weight Hgt 45 in. Len 59 in. Wth 64 in. Weight with factory installed options 914 lbs. Unit Features Clearances • Two Stage Cooling Right 30 in. Front 36 in. Rear 24 in. • Unit Cabinet Constructed of Powder Painted Steel,Certified At 750 Hours Top 120 in. Bottom 0 in. Left 30 in. Salt Spray Test(ASTM B-117 Standards) Note: Please refer to the tech guide for listed maximum static pressures • Full Perimeter Base Rails with Built in Rigging Capabilities ® • Scroll Compressors with Crankcase Heater •rceuw `;; • Single Refrigeration Circuit(2 Pipe) A CERTIFIED..rauuurr • los • Liquid Line Driers(Supplied for Field Installation) • Aluminum Tube/Aluminum Fin Microchannel Coils • Back Seating Suction and Liquid Line Service Valves • Inherently Protected Fan Motors • Low Ambient to 40°F • Side or Bottom Single Point Power Connections • Disconnect Switch • Phase Monitor • Coil Guard • Short Circuit Current:5kA RMS Symmetrical Standard Unit Controller: Smart Equipment Control Board • Anti-Short Cycle Protection, Lead-Lag, Low Voltage Protection,On-Board Diagnostic and Fault Code Display • Safety Monitoring-Monitors the High and Low-Pressure Switches.The Unit Control Board will Alarm on Compressor Lockouts and Repeated Limit Switch Trips. BAS Controller • Smart Equipment Controller with Gateway to BACnet MS/TP(Programmable to Modbus or N2) • Smart Equipment Controller with Gateway to BACnet MS/TP(Programmable to Modbus or N2) Warranty • One(1)Year Limited Warranty on All Other Parts • Five(5)Year Limited Warranty on Compressors Information is subject to change without notice.Check local codes. Printed 04/09/2021 01.4 Controls Split-System Outdoor Split System JohnsonJohnson Controls R-410A Outdoor Project Name: TTSD-Durham Unit Model#: J15YCCOOA2GAE4 Quantity: 2 Tag#:ACU-2&ACU-3 System: J15YCCOOA2GAE4 Factory Installed Options J15YCC00A2GAE4 Equipment Options Option(s) Selected Nominal Cooling Capacity: J15 15 Ton Product Category: Y Johnson Controls Split System R-410A Air Conditioner Product Identifier: C 2-Pipe R-410A Heat Type and Nominal Heat Capacity: COO Airflow: A S an.ara o or Voltage: 2 208/230-3-60 'stallation Options: G HACR Circuit Breaker/Disconnect(Sized for 208 Volts) Phase Monitor Coil Guard Additional Options: AE Smart Equipment Controller with Gateway to BACnet MS/TP (Programmable to Modbus or N2) Product Generation: 4 Field Installed Accessories 0 1HG0428- Hail Guard (74.0 Ibs) 0 S1-NSB8BHN143-0 -Wall 0 S1-NSB8BPN241-0 -Wall 2HG04700524 - H. „ ,,., Temperature and 3% Relative Temperature and 2% Relative Kit; Includes discharge bypass Humidity Combined Sensor, Humidity Combined Sensor, Full valve and Copper pipe fittings fort Warmer/Cooler Display, BLACK, Display, WHITE, NO JCI LOGO, field installation. Used to modulat NO JCI LOGO, NS8000 Series NS8000 Series (0.4 Ibs) oapacit at low load conditions (0.4 Ibs) 0 S1-NSB8BPN243-0 -Wall 0 S1-NSB8BHN240-0-Wall Temperature and 2% Relative O S1-NSB8BHNO41-0-Wall Temperature and 3% Relative Humidity Combined Sensor, Full Temperature and 3% Relative Humidity Combined Sensor, Full Display, BLACK, NO JCI LOGO, Humidity Combined Sensor, No Display, WHITE, JCI LOGO, NS8000 Series (0.4 Ibs) Display, WHITE, NO JCI LOGO, NS8000 Series (0.4 Ibs) 0 S1-NSB8BTN041-0-Wall NS8000 Series (0.4 Ibs) 0 S1-NSB8BHN241-0 -Wall Temperature Sensor, No Display, O S1-NSB8BHNO43-0-Wall Temperature and 3% Relative WHITE, NO JCI LOGO, NS8000 Temperature and 3% Relative Humidity Combined Sensor, Full Series (0.4 Ibs) Humidity Combined Sensor, No Display, WHITE, NO JCI LOGO, 0 S1-NSB8BTN043-0 -Wall Display, BLACK, NO JCI LOGO, NS8000 Series (0.4 Ibs) Temperature Sensor, No Display, NS8000 Series (0.4 Ibs) 0 S1-NSB8BHN243-0 -Wall BLACK, NO JCI LOGO, NS8000 O S1-NSB8BHN141-0 -Wall Temperature and 3% Relative Series (0.4 Ibs) Temperature and 3% Relative Humidity Combined Sensor, Full 0 S1-NSB8BTN141-0 -Wall Humidity Combined Sensor, Display, BLACK, NO JCI LOGO, Temperature Sensor, Warmer/Cooler Display, WHITE, NS8000 Series (0.4 Ibs) Warmer/Cooler Display, WHITE, NO JCI LOGO, NS8000 Series 0 S1-NSB8BPN240-0-Wall NO JCI LOGO, NS8000 Series (0.4 Ibs) Temperature and 2% Relative (0.4 Ibs) Humidity Combined Sensor, Full Display, WHITE, JCI LOGO, NS8000 Series (0.4 Ibs) Information is subject to change without notice.Check local codes. Printed 04/09/2021 .;, 3.t „ .'x, WN IAiY&HfttiA 3Y#fRtY4k4tutdHuidi4i"' W'#^^• !. 6t1i64NkNL¢t Kxrn.Fki'trw.txw+k iaau431WrikuetllutY4 -iFteCAlisiswii4tbstWiirFlAkt ' w,4.# a i . Outdoor Split System JohnsonJohnson Controls Split-System R-410A Outdoor Controls 7 Project Name: TTSD-Durham Unit Model#: J15YCCOOA2GAE4 Quantity: 2 Tag#:ACU-2&ACU-3 System: J15YCC00A2GAE4 Piping&Connection Piping and Electrical Connection Sizes (Inches) MODEL JO7PC J10PC JO7YC J10YC J10YD J12YC J12YD No. Refrigeration Circuits 1 1 1 1 2 1 2 Suction Line OD (in.) 1 1/8 1 3/8 1 1/8 1 3/8 1 1/8 1 3/8 1 1/8 Liquid Line OD(in.) 5/8 7/8 5/8 7/8 5/8 7/8 5/8 Power Wiring Knockout 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 _ Control Wiring Knockout 7/8 7/8 7/8 7/8 7/8 7/8 7/8 MODEL J15PC J15PD J20PC J20PD'J15YC ' J15YD J2OYC J20YD J25YC No. Refrigeration Circuits 1 2 1 2 1 2 1 2 1 Suction Line OD(in.) 1 5/8 1 3/8 1 5/8 1 3/8 15/8 13/8 15/8 13/8 15/8 Liquid Line OD (in.) 7/8 5/8 7/8 5/8 7/8 5/8 7/8 5/8 7/8 Power Wiring Knockout 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 Control Wiring Knockout 7/8 7/8 7/8 7/8 7/8 7/8 718 7/8 7/8 Information is subject to change without notice.Check local codes. Printed 04/09/2021 101 Outdoor Split System Johnson Controls Johnson Controls Split-System R-410A Outdoor Project Name: TTSD-Durham Unit Model#: J40YDCOOA2GAA2 Quantity: 1 Tag#:ACU-8 System: J40YDC00A2GAA2 Cooling Performance Total gross capacity 468.8 MBH Sensible gross capacity .0 MBH Total net capacity V 468.8 MBH01 Efficiency(at ARI) EER - Y Ambient DB temp. 95.0 °F 0 Power input(w/o blower) 37.38 kW i Suction pressure 130 psig Saturated suction temp. 45 °F Refrigerant ;•, , a Refrigerant type R-410A --9,i„. is. il' ' Electrical Data Power supply 208-3-60 Unit min circuit ampacity /151.1 Amos r' Unit max over-current protection V I 175 Amps ,-- Dimensions&Weight Hgt 58 in. Len 129 in. Wth 89 in. Weight with factory installed options 2315 Ibs 40 Ton Clearances • JCI units are Manufactured at an ISO 9001 Registered Facility and each Right 30 in. Front 36 in. Rear 24 n. Rooftop is Completely Computer-run Tested Prior to Shipment. Top 120 in. Bottom 0 in. Left 30 in. Unit Features ✓ Note: Please refer to the tech guide for listed maximum static press es • Four Stage Cooling • Unit Cabinet Constructed of Powder Painted Steel,Certified At 750 lir s�n,€) i • ,7HoursSalt Spray Test(ASTM B-117 Standards) romiiiiitc— us ry -+ • Full Perimeter Base rails with Built in Rigging Capabilities • Dual Circuit 4 Stage Cooling with Scroll Compressor • Solid Core Liquid Line Filter Driers IEI Comment: • Copper Tube/Aluminum Fin Condenser Coil Verify and coordinate load • Sweat Connection Fittings with Div 26. • Single Point Power Connection • Condenser Coil Guards Standard • Short Circuit Current:5kA RMS Symmetrical Standard Unit Controller: Smart Equipment Control Board • An Integrated Low-Ambient Control,Anti-short Cycle Protection,Lead-Lag, Fan on and Fan off Delays, Low Voltage Protection,On-board Diagnostic and Fault Code Display • Safety Monitoring-Monitors the High and Low-Pressure Switches.The Unit Control Board will Alarm on Compressor Lockouts and Repeated Limit Switch Trips BAS Controller • Smart Equipment Controller with Gateway to BACnet MS/TP(Programmable to Modbus or N2) Warranty • One(1)Year Limited Warranty on the Complete Unit • One(1)Year Warranty-Compressors Information is subject to change without notice.Check local codes. Printed 04/09/2021 �� � Outdoor Split System Johnson Controls Johnson Controls Split-System R-410A Outdoor Project Name: TTSD-Durham Unit Model#: J40YDC00A2GAA2 Quantity: 1 Tag#:ACU-8 System: J40YDC00A2GAA2 Factory Installed Options J40YDC00A2GAA2 Equipment Options Option(s) Selected El Nominal Cooling Capacity: J40 40 Tone Product Category: Y Johnson Controls Split System R-410A Air Conditioner Product Identifier: D 4-Pipe Airflow: A Voltage: 2 208/230-3-60 Installation Options: G HACR Circuit Breaker/Disconnect (Sized for 208 Volts) Copper Tube/Aluminum Fin Condenser Coil Additional Options: AA Smart Equipment Controller with Gateway to BACnet MS/TP(Programmable to Modbus or N2) Product Generation: 2 Field Installed Accessories O 1 WS0408- Metal Skid for Fork Truck Handling (225.0 Ibs) O 1 WSO410 -Wooden Skid for Fork Truck Handling (200.0 Ibs) O 2ET077001124- Honeywell T7350, 2 Heat/4 Cool, Auto/Man Changeover, Electronic 7 Day Programmable (2.0 Ibs) O 2LA04714025- Low Ambient Kit 208/230V 40 &50T (3.0 Ibs) 2PM04700124 - Phase Monitor Kit - Includes Control and associated wiring. This accessory provides protection against phase reversal, loss or unbalance. (13.0 Ibs) Information is subject to change without notice.Check local codes. Printed 04/09/2021 Residential Split Ti GUARDIAN* Split-System Outdoor Project Name: TTSD-Durham Unit Model#: TCD48B31S Quantity: 1 Tag#:ACU-7 System: TCD48B31S Cooling Performance :a Total gross capacity 46.1 MBH Ambient DB temp. 95.0 °F . Power input 3.82 kW Suction pressure 130 psig Saturated suction temp. 45 °F }a;: Refrigerant Refrigerant type R-410A Electrical Data I .w Power supply 208/230-3-60 Unit min circuit ampacity 18,4 Amos Unit max over-current protection I 30 Amps Dimensions&Weight Hgt 37 in. Len 37 in. Wth 34 in. Weight with factory installed options 200 lb . Note: Please refer to the tech guide for listed maximum static pressu 111111 nu S I. tTlFlE �'�. •r'; 4 Ton c us.._--. p. Product Features • The TCD models are the latest iteration in our successful LX Series split system air conditioner lineup.Optimized for the 3 phase 13 SEER National Minimum Efficiency,these outdoor units are specifically designed to be matched with Guardian indoor coils,furnaces,and air handlers to provide a IEI Comment: complete system solution. Unit Features Verify and coordinate load • 13 SEER/1-Stage with Div 26. • Environmentally Friendly-CFC-free R-410A refrigerant delivers environmentally friendly performance with zero ozone depletion. • Durable Finish—The coated steel wire fan guard,coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep.Champagne colored powdercoat paint further protects external panels. • Fully Exposed Refrigerant Connections and a Single Panel Covering the Electrical Controls Make for Easy Servicing of the Unit Warranty • Standard One(1)-Year Limited Parts • Standard Five(5)-Years Limited Compressor • Extended Ten(10)Year Limited Parts Warranty when Product is Registered Online Within 90 Days of Purchase for Replacement or Closing for New Home Construction Information is subject to change without notice.Check local codes. Printed 04/09/2021 Residential Split 1)GUARDIAN Split-System Outdoor Project Name: TTSD-Durham Unit Model#: TCD48B31S Quantity: 1 Tag#:ACU-7 System: TCD48B31S Factory Installed Options TCD48B31S Equipment Options Option(s) Selected Product Category: T Guardian Brand Type: C Air Conditioner Nominal Series Efficiency&Staging: D 13 SEER/ 1-Stage Nominal Cooling Capacity: 48 4 Ton Refrigerant: B R-410A Refrigerant Voltage: 3 208/230-3-60 Product Generation: 1 Factory-Installed Options: S Information is subject to change without notice.Check local codes. Printed 04/09/2021 • Outdoor Split System Controls Johnso Johnson Controls Split-System R-410A Outdoor Project Name: TTSD-Durham Unit Model#: J25YCCOOA2GAE4 Quantity: 3 Tag#:ACU-1,ACU-5,ACU- System: J25YCCOOA2GAE4 6 Cooling Performance Total gross capacity 269.8 MBH Sensible gross capacity .0 MBH v' II Total net capacity 269.8 MBH Zit Efficiency(at ARI) EER Ambient DB temp. 95.0 °F Power input(w/o blower) 23.65 kW Suction pressure 129 psig Saturated suction temp. 45 °F Refrigerant Refrigerant type R-410A Electrical Data Power supply 208-3-60 Unit min circuit ampacity `120.3 Amps Unit max over-current protection v 150 Amps Dimensions&Weight Hgt 50 in. Len 59 in. Wth 64 in. Weight with factory installed options 945 lbs. 25 Ton Clearances • Johnson Controls Split System Units are Manufactured at an ISO 9001 Right 30 in. Front 36 in. Rear 24 in. Registered Facility. Top 120 in. Bottom 0 in. Left 30 in. Unit Features ✓ Note: Please refer to the tech guide for listed maximum static pressures • Two Stage Cooling IBM • Unit Cabinet Constructed of Powder Painted Steel,Certified At 750 Hours p� aui c x t r Salt Spray Test(ASTM B-117 Standards) rti r� CEitlFlt ..au*wv W��pI• c us • Full Perimeter Base Rails with Built in Rigging Capabilities • Scroll Compressors with Crankcase Heater • Single Refrigeration Circuit(2 Pipe) • Liquid Line Driers(Supplied for Field Installation) • Aluminum Tube/Aluminum Fin Microchannel Coils • Back Seating Suction and Liquid Line Service Valves • Inherently Protected Fan Motors • Low Ambient to 40°F • Side or Bottom Single Point Power Connections • Disconnect Switch • Phase Monitor • Coil Guard • Short Circuit Current:5kA RMS Symmetrical Standard Unit Controller: Smart Equipment Control Board • Anti-Short Cycle Protection, Lead-Lag,Low Voltage Protection,On-Board Diagnostic and Fault Code Display • Safety Monitoring-Monitors the High and Low-Pressure Switches.The Unit Control Board will Alarm on Compressor Lockouts and Repeated Limit Switch Trips. BAS Controller • Smart Equipment Controller with Gateway to BACnet MS/TP(Programmable to Modbus or N2) • Smart Equipment Controller with Gateway to BACnet MS/TP(Programmable to Modbus or N2) Warranty • One(1)Year Limited Warranty on All Other Parts • Five(5)Year Limited Warranty on Compressors Information is subject to change without notice.Check local codes. Printed 04/09/2021 Outdoor Split System Controls Johnson4' Johnson Controls Split-System R-410A Outdoor Project Name: TTSD-Durham Unit Model#: J25YCC00A2GAE4 Quantity: 3 Tag#:ACU-1,ACU-5,ACU- System: J25YCC00A2GAE4 6 Factory Installed Options J25YCC00A2GAE4 Equipment Options Option(s) Selected •ro:udtCategory: Y Johnson Controls Split System R-410A Air Conditioner Product Identifier: C 2-Pipe R-410A Heat Type and Nominal Heat Capacity: COO Airflow: A Standard Motor Voltage: 2 208/230-3-60 Installation Options: G HACR Circuit Breaker/Disconnect(Sized for 208 Volts) Phase Monitor Coil Guard Additional Options: AE Smart Equipment Controller with Gateway to BACnet MS/TP(Programmable to Modbus or N2) Product Generation: 4 Field Installed Accessories 0 1HG0429- Hail Guard (37.0 Ibs) 0 S1-NSB8BHN143-0 -Wall 0 S1-NSB8BPN241-0 -Wall Temperature and 3/° Relative Temperature and 2/o Relative 04700624 - Hot Gas Bypas�`;; p p , Includes discharge bypass r Humidity Combined Sensor, Humidity Combined Sensor, Full valve and Copper pipe fittings f. Warmer/Cooler Display, BLACK, Display, WHITE, NO JCI LOGO, field installation. Used to modul.:i NO JCI LOGO, NS8000 Series NS8000 Series (0.4 Ibs) capacity at low load conditions ," (0.4 Ibs) 0 S1-NSB8BPN243-0 -Wall • 0 S1-NSB8BHN240-0 -Wall Temperature and 2% Relative f.x O 2LA04702024-Low Ambient To Temperature and 3% Relative Humidity Combined Sensor, Full 0° F (3.2 Ibs) Humidity Combined Sensor, Full Display, BLACK, NO JCI LOGO, O S1-NSB8BHNO41-0 -Wall Display, WHITE, JCI LOGO, NS8000 Series (0.4 Ibs) Temperature and 3% Relative NS8000 Series (0.4 Ibs) 0 S1-NSB8BTN041-0 -Wall Humidity Combined Sensor, No 0 S1-NSB8BHN241-0 -Wall Temperature Sensor, No Display, Display, WHITE, NO JCI LOGO, Temperature and 3% Relative WHITE, NO JCI LOGO, NS8000 NS8000 Series (0.4 Ibs) Humidity Combined Sensor, Full Series (0.4 Ibs) O S1-NSB8BHNO43-0 -Wall Display, WHITE, NO JCI LOGO, 0 S1-NSB8BTN043-0 -Wall Temperature and 3% Relative NS8000 Series (0.4 Ibs) Temperature Sensor, No Display, Humidity Combined Sensor, No 0 S1-NSB8BHN243-0 -Wall BLACK, NO JCI LOGO, NS8000 Display, BLACK, NO JCI LOGO, Temperature and 3% Relative Series (0.4 Ibs) NS8000 Series (0.4 Ibs) Humidity Combined Sensor, Full 0 S1-NSB8BTN141-0 -Wall O S1-NSB8BHN141-0-Wall Display, BLACK, NO JCI LOGO, Temperature Sensor, Temperature and 3% Relative NS8000 Series (0.4 Ibs) Warmer/Cooler Display, WHITE, Humidity Combined Sensor, 0 S1-NSB8BPN240-0-Wall NO JCI LOGO, NS8000 Series Warmer/Cooler Display, WHITE, Temperature and 2% Relative (0.4 Ibs) NO JCI LOGO, NS8000 Series Humidity Combined Sensor, Full 0 S1-NSB8BTN143-0 -Wall (0.4 Ibs) Display, WHITE, JCI LOGO, Temperature Sensor, NS8000 Series (0.4 Ibs) Warmer/Cooler Display, BLACK, NO JCI LOGO, NS8000 Series (0.4 Ibs) Information is subject to change without notice.Check local codes. Printed 04/09/2021 Johnson '01 Outdoor Split System Controls Johnson Controls Split-System R-410A Outdoor Project Name: TTSD-Durham Unit Model#: J25YCCOOA2GAE4 Quantity: 3 Tag#:ACU-1,ACU-5,ACU- System: J25YCCOOA2GAE4 6 Piping&Connection Piping and Electrical Connection Sizes (Inches) MODEL JO7PC J10PC JO7YC J10YC J10YD J12YC J12YD No. Refrigeration Circuits 1 1 1 1 2 1 2 Suction Line OD(in.) 1 1/8 1 3/8 1 1/8 1 3/8 1 1/8 1 3/8 1 1/8 Liquid Line OD (in.) 5/8 7/8 5/8 7/8 5/8 7/8 5/8 Power Wiring Knockout 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 Control Wiring Knockout 7/8 7/8 7/8 7/8 7/8 7/8 7/8 MODEL J15PC J15PD J20PC J20PD J15YC J15YD J2OYC J20YD J25YC No. Refrigeration Circuits 1 2 1 2 1 2 1 2 1 Suction Line OD (in.) 1 5/8 1 3/8 1 5/8 1 3/8 15/8 13/8 15/8 13/8 15/8 Liquid Line OD(in.) 7/8 5/8 7/8 5/8 7/8 5/8 7/8 5/8 7/8 Power Wiring Knockout 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 Control Wiring Knockout 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 7/8 Information is subject to change without notice.Check local codes. Printed 04/09/2021 :y Bill Wre.ai ue+e+aws:.:a+++aew.u±.a.woswu:eaasex»ru,aae..uawaa.�a:isxb+waa�«m:.�twesswnu. fiswrwxaN.vu. aw�utsasw.trawa;.. o R E G o N Submittal Unit Dimensional Drawing 735 SW 20 " Place 230 , Portland , OR 97205 PHONE (971) 717-7123 Johnson 1 Outdoor Split System Controls Johnson Controls Split-System R-410A Outdoor Project Name: TTSD-Durham Unit Model#: J15YCC00A2GAE4 Quantity: 2 Tag#:ACU-2&ACU-3 System: J15YCC00A2GAE4 Consolidated Drawing _ I 2 3 .__ 4 5 6 T 8 9 IO ,, 12 13 14 15 •6 '.. NOTES: U i CENIER OF GAAOITY I, FOR OUTDOOR USE ONLY. N I OPERATING LOCATION;BASE UNIT; 4 POINT CORNEA LOADS MS; 1845E UNIT) TONNAGE I !WEIGHT (LIT' 2- WEIGHTS SHOWN ARE FOR OPERATING, WITHOUT HAIL GUARDS 1 i 18A5E OW, C Y A 8 I c I 0 H i 3. MIN. CLEARANCES TO BE. N RIGHT SIDE; 30 17621 15 PCFPH 666 l4397 32.5 1825.51 33 1438.21 266 [1217 214 E1241 211 (481 211 1451 LEFT SIDE: 30 [2621 15 PDIPJ 942 14217 34 1663,63 32.5 1425,51 243 11107 215 11251 225 G 021 199 1901 FRONT: 36 (9141 REAR; 24 16101 TOP: 120 130481 BOTTOM: 0 101 IS 1111/6J 891 14061 32.5 1.825,51 31.5 1800.17 235(1011 242 11101 212 1841 206 1431 4. FOR SMALLER SERVICE AND OPERATIONAL CLEARANCES REAR _t_ CONTACT JOHNSON CONTROLS APPLICATION ENGINEERING A 9 DEPARTMENT, 5. DIMENSIONS IN 1 ] ARE IN MILLIMETERS OR KILOGRAMS. - 1;i! LI PD/Pd A YD/YJ UNITS ONLY, 1(i [ SYSTEM DATA t • [ DIRECTION OF AIRFLOW �„ A [I SYSTEM I SYSTEM 2 H CENTER OF GRAVITY I I SUCTION LINE LIQUID LINE SUCTION LINE LIOUID LINE 4T.44 1''1k MI- 0.D 0.0 0 0 0.D. (1205,01 11 F,,� W• PCIPH 1.625 141,281 0.8t5 122,231 NIA NM T r 1.06 �' RIGHT [60.0.31 C2T,01 ITT T T.,, Y TOP • �t PD9P3 I.115 134,934 0.625 (15.881 I.3T5 131,933 0.625 E15,68T a YDI YJ I.375 [34931Min 1.175 134.931 0-625 [15.881 i G 335 269 C i l R ::) r_ ._ __._ 145,3i 168.21 D C I9TT1OM l 6.53 1 1165,81 14,43 - 0 r. 14.14 F I 1 1366.61 I92.81 I [366,71 r ram-3.56 --.1 12358,91 190,51 MAW DSc au 7u HAIL GUARD CONVENIENCE OUTLET 1 SCALE 0.500 HAIL GUAR SYSTEM 2© INSTALLED, COVER iOPTIONAL3 IFIELD INSTALLED, OPTIONAL! OPTIONAL! f ' - - - - - t 9' ' j. PWR WIRING ENTRY 8 1 2%0(347931 X.Q. �l 1 CTL 8O% \V r ~ ACCESS I Ti024,4] 9 88 44,58 �� I 36.23 1250,81 1. 1/132,41 L. / [920,2I r 16.13 ���' 13 13 I, 5 � 2409,81 1333,62 i 12.13 `ram 1308.01 !,, I ,1..m.__1_ a.. 4 Ira .6_J: R3a C?T4T� _.�- oa C""'7 Ca) oC. A k I SYSTEM 1 DISCONNECT SWITCH COVER 1.15 2TXL WIRING. ENTRY 11.35 (OPTIONAL/ (120,11 �122,23) C [440,81 -. 18 85 1.92 -- 1'--COIL GUARD -SEE BASE RAIL 20.62 T4T8,91 148.11 /OPTIONAL) DETAIL [523,71 -y ( 3.13 22.62 3.92 119,61 15t4,51 UfA YEMI - 64.00 199,51~_ 59.00 HAIL GUARD NOT SHOWN IN THIS VIEW 11625,61 [1498,61 MIL 11BE RGHT VEW 8 COIL GUARD NOT SHOWN IN THIS VI[W COIL GUARD NO" SHOWN !N THIS VIEW nN DATE REVISION RECORD 'EC NO I DR CA ENG Min AO6L4,R6AAE1K4"i vsrstE,ss,aern s 1,sosxci.Ants K,4a A:r st:ss+m AAD q Dls.,sstoe 3utir ARD NCA ' ee 6AAR1,D,0 0011 it ET iAtt rR t.l,D,ilL M R,ADT of DIAEIDDA Aer M THE Q CtAAAOTEA0STI<5 PEA A 02-1)-20 NEW ORAWING ;FAN U5 T-PRE045-40UF45HI 15168 IIOP RCN 5AA A. 04 001 014 svo4 i TO ai.4n•tiwui K,nn sr,r+tE it,D.ssrw Ee.isws 84 1014{i6-6i "'� DAWN no AWE Y14,f 266; MAif RIAI 1V -..jFlaw.inwalwRancmono SUBMITTAL DWG, OUTDOOR SRLI1. MI NOT APPI.ICABEC n .N sAii..: nAEear1: W,t 15 TON, 2 & 8 PIPE, 44,5' CABINET IK9,Fc NOT APPLICABLE r 666 I POW 19-11 a MD,CKC NOW :.4t 518E A.... CNN i 1Wy It'll-N'u41CrLA(90CEIWI- : 6IP JOHNSON CONTROLS coo'ro 7 REv CR6 9.AK4t M- -N i AAAIYs= :f UNITARY PAO2L4T5 GROUP A . 4,t6 DogssiWtAN i,tM,RCt PANT WO- SCAUr 0,080 1 *OM Kitt PAI4r NORM A.Cm 19669 SOT 40 A Or I 1 2 3 4 5 6 T 8 4 10 I P2 13 IA 15 ;6 Information is subject to change without notice.Check local codes. Printed 04/09/2021 Olt Outdoor Split System Johnson It Controls Johnson Controls Split-System R-410A Outdoor Project Name: TTSD-Durham Unit Model#: J15YCC00A2GAE4 Quantity: 2 Tag#:ACU-2&ACU-3 System: J15YCC00A2GAE4 Corner Weights&Center of Gravity LEFT v. • D - `A LEFT / \ / DIM X ( ) 1 1 D A ` / DIM X / \ CG / N \I ` / CG \' ....,,, / FRONT ' s ( ) REAR FRONT REAR WIDTH - � / B / \ j / WIDTH 44—DIM Y —► ) 4 LENGTH ►. \ / RIGHT C\ `..� / s'... / B JO7PC,J10PC, 4 DIM Y—i. JO7YC,J10YC,J10YD, J12YC,J12YD .f— LENGTH NA RIGHT J15PC.J15PD, NOTE: Front of unit is considered the side having the unit J20PC,J20PD, control box. J15YC,J15YD, J2OYC,J20YD J25YC Corner Weights & Center of Gravity AC/HP Units Model Weight(lbs.) Center of Gravity(in.) 4 Point Load Location(lbs.) Shipping Operating X Y A B C D JO7PC 421 430 17.3 33 110 130 103 87 J10PC 543 574 16.4 32.3 153 161 134 127 J15PC 947 968 32.5 33 266 274 217 211 J15PD 921 942 34 32.5 243 275 225 199 J20PC 1116 1152 32.1 30.8 300 301 276 275 J20PD 1090 1126 31.2 31.8 311 295 253 267 JO7YC 390 387 17 32.3 99 113 94 82 J10YC 499 497 17.3 32.3 124 147 122 103 J10YD 493 490 17.4 32.5 123 147 120 100 J12YC 499 497 17 32.3 127 145 120 105 J12YD 493 490 17.4 32.5 123 147 120 100 ,. YC M -909 32.5 31 u.x,..-''23 `` 246 215 209 ' J15YD 899 894 32.5 31.5 235 242 212 206 J2OYC 945 942 30.3 31.0 261 234 212 236 J20YD 930 927 32.7 31.8 244 255 218 210 J25YC 945 942 30.3 31.0 261 234 212 236 Information is subject to change without notice.Check local codes. Printed 04/09/2021 .........ate. .. Outdoor Split System JohnsonrJohnson Controls S lit S stem R-410A Outdoor Jj( Controls P� - Y Project Name: TTSD-Durham Unit Model#: J40YDC00A2GAA2 Quantity: 1 Tag#:ACU-8 System: J40YDC00A2GAA2 Unit Dimensions REAR LEFT --- A i�,, •-- - ....4111,gt:--V7,--,5*>" simft-- . i _ It • ca j/ ° . E ^ ; e ,. • RIGHT •FRONTS® G° F Y J**YD Unit Dimensions Unit Dimensions(Inches) Model A B C D E F G H J30YD 128.5 88.5 37.5 41.8 40.0 46.1 37.1 23.6 J50YD 128.5 88.5 57.7 41.8 40.0 46.1 37.1* 23.6 Piping And Electrical Connections Unit Clearances Piping connections are made from the rear of the unit. Con- Location Dimensions nections can be made directly to the suction and liquid line Overhead(Top)1 120` service valves. Front access panels 36' Piping can be routed to the unit from the left or right side. Left Side 30' Right Side 30' Electrical connections for power and control wiring is made Rear 24 from the front of all units, left of the electrical control box Bottom o access. See piping sizes and electrical knockout details. 1 Units must be installed outdoors. Overhanging structures or shrubs should not obstruct condenser air discharge. 2 Adequate snow clearance must be provided if winter operation is expected. Information is subject to change without notice.Check local codes. Printed 04/09/2021 'Diu333313¢0t4.30440440uM0343,341.1.titri:at*itt ,wr+ w«,1. K«ana..aae»ua,u ma Ma«p t"r.y..,„w+0+.04.4.14.4.utw+nw.afarx: .1.4.w++::.. ti, Outdoor Split System Johnson Controls Johnson Controls Split-System R-410A Outdoor Project Name: TTSD-Durham Unit Model#: J40YDC00A2GAA2 Quantity: 1 Tag#:ACU-8 System: J40YDC00A2GAA2 Corner Weights&Center of Gravity Weight And Dimension's Corner Weights&Center Of Gravity(Inches) Unit WeightLbs. Unit Dimensions Unit Model ( ) (Inches) A B C D Dim X Dim Y Weight Weight Shipping Operation Length Width A to B D to C J30YD 1875 1895 128.5 88.5 404 537 533 401 55.2 44.1 934 941 J50YD 2345 2381 128.5 88.5 486 693 685 481 53.0 44.0 1166 1179 I C D 1 / CG WIDTH k ( /DIM Y � B A -� DIM X -• LENGTH Information is subject to change without notice.Check local codes. Printed 04/09/2021 Outdoor Split System Johnson Controls Johnson Controls Split-System R-410A Outdoor Project Name: TTSD-Durham Unit Model#: J40YDCOOA2GAA2 Quantity: 1 Tag#:ACU-8 System: J40YDCOOA2GAA2 Piping and Connection 40&50 Ton Piping Connections �+ r .L . • • J,�. t ,!, . JI ... _,.,._ .. . __ .. _, .. ...... ,. = c, — 0 , ,I, 57.689 -- :; _ •fi - e LJ ' 10.97� 11.385 Ie` ‘)ao . oft? .E i i 37.731 Liquid(Sys 2)i • - Suction(Sys 2) 41.934 Suction (Sys 1) 46.206 Liquid(Sys 1) -. 50.409 - 88.140 Piping And Electrical Connection Sizes(30/40/50T) (Inches) Connection Entry Size Suction Line Sys#1 1-5/8 OD Liquid Line Sys#1 7/8 OD Suction Line Sys#2 1-5/8 OD Liquid Line Sys#2 7118 OD Power Wiring Knockout SEE BELOW Control Wiring 7/8 HOLE Electrical Power Knockout Sizes(Inches) Connection Entry 30 4O OT123OV 30-40-50T/460-575V Power Wiring oi.:2 1-1/2' Information is subject to change without notice.Check local codes. Printed 04/09/2021 YYrtxa.4naY#aW tNk3'v6 W'Y.[ e.+ . y_ rr. ...Y+:}✓+8"14d . _. ...i:vudv �., Johnson i Outdoor Split System Controls Johnson Controls Split-System R-410A Outdoor Project Name: TTSD-Durham Unit Model#: J40YDC00A2GAA2 Quantity: 1 Tag#:ACU-8 System: J40YDCOOA2GAA2 Wiring Diagram 40&50 Ton Power and Control Wiring Connections 6.11, P (.. 4 P, •.•• V • : •V • •. . • Control Wiring Power Wiring cAuma MINIVIIIMMIN 57.689 i 1. 7 • _ _ - t. • 33.049 . 29.799 • i or • 19.358 20.858 g. 22.358 • 88.140 Information is subject to change without notice.Check local codes. Printed 04/09/2021 7. Residential Split IL:GUARDIAN' Split-System Outdoor Project Name: TTSD-Durham Unit Model#: TCD48B31S Quantity: 1 Tag#:ACU-7 System: TCD48B31S TCD Physical&Electrical Gen2 PHYSICAL AND ELECTRICAL DATA MODEL TCD30',TCD36 TCD42: TCD60 TCD30 TCD36 TC1342 TCD48 TCD60 TCD36 TCD481TCD60 BUS B325 B32S B318S 842$ B425 B42S B41SS B41SS B52S B51SS1B51SS Unit Supply Voltage 460V,30,60Hz 575V,30,60Hz Normal Voltage Range 1 j 432 to 504 540 to 630 Minimum Circuit Ampacity 11.91 14.34 1529 21.2 5.67 7.85 7 68 8.4 10.3 5 30 6.6 7.7 Max.Overcurrent Device Amps 2 20 20 25 35 15 15 15 15 15 15 15 15 Min,Overcurrent Device Amps 3 15 15 20 25 15 15 15 15 15 15 15 15 Type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Compressor Rated Load 8.89 10.43 11.19 15.9 4.22 5.76 5.63 6.2 7.7 3.77 4.8 5.7 Locked Rotor 58.0 73.0 84.0 110.0 38.0 38.0 44.0 41.0 52.0 36.5 33.0 38.9 Crankcase Heater No No No No No No No No No No No No Factory External Discharge Muffler No No Yes No No No Yes No No No No No Fan Diameter Inches 22 22 24 26 22 22 24 24 26 22 24 26 Rated HP 1/8 1/4 1/4 1/4 1/8 1/4 1/4 1/4 1/4 1/4 1/4 1/4 Rated Load Amps 0.80 1.3 1.3 1.30 0,40 0.65 0.65 0.65 0.65 0.58 0.58 0.58 Fan Motor Nominal RPM 1075 850 850 850 1075 h 850 850 850 850 850 850 850 Nominal CFM 2950 3275 3550 4300 2850 3200 3650 3650 4075 3300 3550 4125 Face Area Sq.Ft. 13.83 17,37 18.74 23.40 13.83 17.37 18.74 18.74 23,40 17.37 18.74 23.40 Coil Rows Deep 1 1 1 1 1 1 1 1 1 1 1 1 Fins/Inch 23 23 23 23 23 23 23 23 23 23 23 23 Liquid Line Set OD(Field Installed) 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line Set OD(Field Installed)° 3/4 3/4 7/8 1-1/81 3/4 3/4 7/8 7/8 1-1/81 3/4 7/8 1-1/81 Unit Charge(Lbs.-Oz.)5 3-15 , 4-10 4-15 5-12 3-15 4-10 4-15 4-15 5-12 4-10 4-15 5-12 Charge Per Foot,Oz. 0.62 0.62 0.67 0.75 0.62 0.62 0,67 0.67 0.75 0.62 0.67 0.75 Operating Weight Lbs. 140 160 200 205 140 160 200 200 205 160 200 205 1. Rated in accordance with AHRI Standard 110-2012.utilization range W. 2. Dual element fuses or HACR circuit breaker.Maximum allowable overcurrent protection. 3. Dual element fuses or HACR circuit breaker.Minimum recommended overcurrent protection. 4. For applications with non-standard vapor line sizes.see the"Applications&Accessories section of this Technical Guide. 5. The Unit Charge is correct for the outdoor unit,smallest matched indoor unit.and 15 feet of refrigerant tubing.For tubing lengths other than 15 feet,add or subtract the amount of refrigerant,using the difference in actual tineset length(not the equivalent length)multiplied by the per toot value. DIMENSIONS _! _ C_"'� Unit Dimensions Refrigerant Connection - (Inches) Service Valve Size -i .11-11 Model A B C Liquid Vapor 11 TCD30B(3,4)2S 30 29-1/4 29-1/4 3/4 __ TCD368(3,4,5)2S 36-1/4 29-1/4 29-1/4 TC1)428(3,4)25 33-1/4 35-1/4 31-3/4 A `_ TCD8O13(3,4,6)1S 38-1/4 38 34-1/4 7/81 t Adapter fitting must be field installed for the required 1-1/B"line set_ �- All dimensions are in inches and are subject to change without notice. - Overall height is from bottom of base pan to top of fan guard. Overall length and width include screw heads. Information is subject to change without notice.Check local codes. Printed 04/09/2021 Outdoor Split System 1 Johnson '� Controls Johnson Controls Split-System R-410A Outdoor Project Name: TTSD-Durham Unit Model#: J25YCCOOA2GAE4 4 Quantity: 3 Tag#:ACU-1,ACU-5,ACU-6 System: J25YCCOOA2GAE4 Consolidated Drawing I 2 3 4 5 6 7 8 -�- 9 10 It 12 13 f1 I 16 NOTES: U CENTER Of GRAVITY I, FOR OUTDOOR USE ONLY. N OPERATING TONNAGE 1 WEIGHT I1.651 LOCATION(BASE UMW 4 POINT CORNER LOADS 0.8S1 (BASE MU 2, WEIGHTS SHOWN ARE FOR OPERATING, WITHOUT HAIL GUARDS, 1 (BASE UNIT) 9 Y A B C 0 M 3. MIN. CLEARANCES TO BE. P RIGHT SIDE: 30 (7621 20 PC/PH 1152 15231 32,1 18)6,31 30.6 1762,31 300 11361 301 11311 276 11251 275 1124.71 LEFT SIDE: 30 17621 REAR 20 PO1PJ 1126 15113 31.!1742.51 31.8[807,T1 III (III) 215 11341 253 11157 26t[121] FRONT: 36 (9141 A( II REAR: 24 (6101 1 , 20 ICYYH 9Y2 1/211 30.3 1169.61 31.0 1781,41 261 11181 234 1106) 212 1961 236 11011 TOP: 120 130481 . _---• BOTTOM: 0 I.01 20 YD/Y1 921 14211 32.1 1810,61 31,8 1607.11 244 11111 255 11101 21$1191 210 1451 ..14, FOR SMALLER SERVICE AND OPERATIONAL CLEARANCES , CONTACT JOHNSON CONTROLS APPLICATION ENGINEERING .. � � DEPARTMENT 5. DIMENSIONS IN 1 1 ARE IN MILLIMETERS OR qt 44 KILOGRAMS. t1205,01 • •, . L.I. I ®PD/PJ & YD/TJ UNITS ONLY, +. • • 'F llr SYSTEM DATA 1 M —>• DIRECTION OF AIRFLOW LEFT ' SYSTEM 1 SYSTEM 2 41 CENTER OF GRAVITY T SUCTION LINE LIQUID LINE SUCTION LINE LIQUID LINE • RCM I6 1D1 1,281 0. 10.10.2,231• ON.DIA. 2,37 —I O6 OM.IDA (60,31 127,0) o A r c 14_A5 G TOP 6.54 1166,21 I PPfPJ 1,115 134,931 6.025 115,661 1,375 E31,93) 6,623 113,861 3.75 + (367,0] TOM 1.375 134,131 0,625 115,661 1.315 134,131 6,625 115,681 195,31 2.69 14.45 [58.21 [36T,01 BOTTOM (92.90 I -1 12359,71 r 1-^3.56 --I TCP_MER 1 E90,51 USE RAC n97AW HAIL GUAR) AIL GUARD SCALE 0.500 (F[ELD INSTALLED. SYSTEM 2 16 CPON INSTALLED, OPTIONAL) OPTIONAL) 1 4 CONVENIENCE OUTLET COVER (OPTIONAL) PWR WIRING ENTRY11 ... uppg. i 14 48.14 2R 01.375 K.O, 4 CTL BOX 11224.11 134,431 I ACCESS 1d,27 i 1 A 50.08 A [)124,/1 9,13 tI2T2,01 0 1,■i [?. , 4 i t231.81 p (409381 13'1361 lir h�Vl. 11,3841 " ` VIIIIMATIWII I / (1.35 1 SYSTEM I 4.75 CTL WIRING ENTRY i C COIL GUAR SEE BASE RAIL 18.85 1120,71 25 G90,875 K.O. C 1 (OPTIONAL) DETAIL 1478,91 DISCONNECT SWITCH COVER 1.92 122,231 20,62 (OPTIONAL) 148,61 3.14 1 1523,71 LE LYA I1 22.62 3.92 (19,71 HAIL GUARD NOT SHOWN IN THIS VIEW (574,51 199,61 64.00 L. 59.00 ',, 8 11625,61 EINWill2 BletiLYIES11498,61 6 COIL GUARD NOT SHOWN IN THIS VIEW COIL GUARD NOT SHOWN IN THIS VIEW [[ GATE REVISION RECORD EC NO DO CM DIG 1YIM MNLt PtOxt,w ALYF ttWt'tlttt awn it tx[141:MAYYit"07 It("4":•AMt t0 0*.1t+w m tt0 YEr 1 LEY' t Got tD tC sootOII T(tit It+tt ft tMtF T t tAtr w tINLC•L tt!oo iY[ CYAAKTEAI$TIC$/EA A 02-I I-TO NEW DRAWING (FROM UST-PRE006-40Dr50N1 75768 LOP RCN 5AA 'VDwat'Yt trot II TO ot.YDY t1n,Yor *Irr$t tf.Ct0A•r.01630a100Yt0Y H POP-STD-0I rQ1 DAARlN6 PE•AM Y1/,A•200f WY1 Rt Al j Ng, �I 1.1Yuu*wu 1:101:1':: SUBMITTAL DWG, OUTDOOR SPLIT, TYPE NOT APPLICABLE A f Y mg „n—,au kW KUM. * I 20 8 25 TON, 2 L d PIPE, 50" CAB to IAC NOT APPLICABLE ®t®088 1.1A1EAN I2-II-N IW ILKY WI*8t: t 01 Slit A CMY •,80001T11-N T0001404$81C1lw= ! OM JOHNSON CONTROLS coo Q REV I EM9 $ARM 12-+1-N Dtun' tf UMITARY PRODUCTS 6R0UP J00377" A ,W;'6 tIMA$Idn MIt itIt,9L1 PA•I 60- 1 1. uALt O,Ha10 OPE uM1 MO NORMAR, OA 73069 $YT YO 1 Or1 I 2 3 4 5 6 7 8 1 10 12 13 14 IS 16 — Information is subject to change without notice.Check local codes. Printed 04/09/2021 Johnson Ott Outdoor Split System Controls Johnson Controls Split-System R-410A Outdoor Project Name: TTSD-Durham Unit Model#: J25YCC00A2GAE4 Quantity: 3 Tag#:ACU-1,ACU-5,ACU- System: J25YCCO0A2GAE4 6 Corner Weights&Center of Gravity LEFT D ^ \A LEFT / ` / I 4 D ..� A DIM X II DIM X / \ CO / \ \ / FRONT C )°5ii 1 ) REAR FRONT REAR ti WIDTH \ WIDTH .II--DIM Y —► I ) 1 1 LENGTH ► \ / RIGHT C\ �.. .� — B JO7PC,J10PC, JO7YC,J10YC,J10YD, DIM Y—i.- J12YC,J12YD 4 LENGTH RIGHT J15PC,J15PD, NOTE: Front of unit is considered the side having the unit J20PC,J20PD, control box. J15YC,J15YD. J2OYC,J20YD J25YC Corner Weights & Center of Gravity AC/HP Units Model Weight(lbs.) Center of Gravity(in.) 4 Point Load Location(lbs.) Shipping Operating X Y A B C D JO7PC 421 430 17.3 33 110 130 103 87 J10PC 543 574 16.4 32.3 153 161 134 127 J15PC 947 968 32.5 33 266 274 217 211 J15PD 921 942 34 32.5 243 275 225 199 J20PC 1116 1152 32.1 30.8 300 301 276 275 J20PD 1090 1126 31.2 31.8 311 295 253 267 JO7YC 390 387 17 32.3 99 113 94 82 J10YC 499 497 17.3 32.3 124 147 122 103 J10YD 493 490 17.4 32.5 123 147 120 100 J12YC 499 497 17 32.3 127 145 120 105 J12YD 493 490 17.4 32.5 123 147 120 100 J15YC 914 909 32.5 31.5 239 246 215 209 J15YD 899 894 32.5 31.5 235 242 212 206 J2OYC 945 942 30.3 31.0 261 234 212 236 J20YD 930 927 32.7 31.8 244 255 218 210 Information is subject to change without notice.Check local codes. Printed 04/09/2021 `rigwt -r• :maam t.. JB,4 O R E G O N Submittal Electrical Notes and Wiring Diagrams 735 SW 20t " Place 230 , Portland , OR 97205 PHONE (971) 717-7123 ' 01 o 01, 0 NJ co IV H (71'‹ 0 I A I e I C I I E I F I G I I I K I L I 2 25 TON C❑NDENSING UNIT - C❑❑LING (2 PIPE) ELEMENTARY DIAGRAM CD rn ® 7 MI POWER Y __ __701/R - iHl'" 107/R ®710—DIM - \ R I. ] 2160-3-60 - 100R�j ® t02L v573-3-60 I 49i R 4 USE COPPER 3 PRESSURE CRITROLS CRIDUCTORS OILY-- __-]03/O___-__ _ H' 109/0 0 0 103, 13127 DEVICE OPERATING PRESSURE(PSIGO ®4 4 Q 4 0 0 __-2. ® OM,� n OPEN ./- CLOSE ./- THS r---]40/PN�` UO/PR or -]41/BR HPl 623 23 SW 23 G ' 7 4C/0 _�• 113/0 I EL LPI 50 5 71 5 I 7 T13-2 n9 -M MUD. 1�2F.1 I15/Y �I O2. ''I (r--1 ^�W911 f�t� I g g , ___ EL La7 r-lrl-lr---j 1 222/o-CD---- 1 I ® � J.l M1 rti.,35 L_�3 © --- 4- ® llffAra - 1 1 1 1 I I ® 1 1 1 1 1 �� 1•��III �'" ®� TM I 0 O. 'lS °G - 5 5� :E T13-3 r- i • ANI2r 2C3 EL T t�/ GRN F _.ti 1K P4 P22 PS as-S3 3B6/N-'ri :i 60 • 124/0-1141 1® 117, 1 Q 11. 3R C -w •-I 1 �� 1}288/BL___-1 1 O BK O6AN4 �{ N6 e}ee9/G TEL r �.ERN 73 ��-�-�BLK{309/6� �iw a ® 3, IRI BR V311H/0 . S 0 ST1 ( _ 4 1 a,u� 1 219/GY Al N4[B}23H/BR _ `F -+ UCB .-{, _ x� LIMA ro T ■ 3]/PR ®Nx ® -- 1w/BK NPaz S2 •-II ", 3}-213/V / -�IIy- 129/BR�M{�-® 105/BL f�® (�\ x{303/1'{( = 4•K21 • - 3)-2041 000 43/12 A')'83-2 �� ()TIC) �. Y�/�/�}BL EI N{302/r{ +a •-I u 5}-200^' O®O 21I/PIJJ '•"' 130/PR �Sl K1 S9 OAT C • • u O HP +�a 'LO CON FC-PC. _ TONSEENAILAFoR THER j__ m VVOLTA ILK-M-IIX ® ®ve/o • 5-07 ISM/ FRI —u R _-• 1 6 1� -- 12� ♦y SE n 703-z 0.K BLK-1ux3 119/0- 2y -'�-• 7 „u/t LPI I --- 175 NP 2]5 VAC = /� i_2. TH3-1 ~ -y-• l� i1117/R 4 347/R Igor J• - 8 l5/HL I e RE➢ ) • h ..._....• F.- • • n- 100----c I 20HV 5, y 1 230V vRI O TB3-2 a T2 TB3-2 k u u` = � ., A ATTLEMAW 175 NB' 2y gC = -" r //00----Kyy/ I- a '�- y O 1 " -I > x ° N1T I 1 I I -x /'''''R�On_-213130//fl; -151/ __ }l s/PB, ! 2 REDJ . TH3-3 1iLJR�1TJ AI� �� B]/BR 1226 /BRI _ ®r PS ly V DETAIL A 3.4 AM T g_ _ __ rt 2 I II o • /R---J CAUTION-OPEN ALL DISCONNECTS o ___-_ 1 BEFORE SERVICING THIS UNIT. a G5829897A REV A SHT 1 OF 2 c m Q cn Tn m 3 -1 cn .< o n N . CU-2 • : U-3. c cri 0 1 A I B 1 c 1 A I E I P I G I H I ' I K I 1 I n 2 15 TON C❑NDENSING UNIT - C❑❑LING (2 PIPE) ELEMENTARY DIAGRAM o rn j iv POWER ____ PER SUPPLY �I, • 701/R IB1 B1 107 R--Or-E —I01/BK COMPRI CC 0 208/230-3-60 $$ N 460-360 -___�P_. �L —]02/H' �H- (08/BR ©1 I® IOPJIL 3/�� 0 USE COPPER ID PRESSURE CONTRELS CONDUCTORS ONLY---- E F' --- ]03 r BS l09/0 ©r —103/1 DEVICE OPERATING PRESSURE CPSIG) (I'YI '� IV OPEN ,/- CLOSE ,/- ®Y Q O (Y O O ---]40/PR • 1HVPR ® 1 ® ®EMI HP1 625 25 500 25 �----- ]42/0- • 113/0 m LP1 50 5 ]L 5 /J] TB3-2 819/BR� T'�i. 013 1© 1L5/Y Rd• le ORN e • tc C H2 if 2 56/BR—> BLK ,Bi or,,,,,, ----h r h . 202/1 St �m IMP ,,BEr /'1 '35 TB3-1 1 1 1 1 IINIIIII 3 Q1 m I K Off AN3 ya 40 a Ru > Na TB3-3 • Lle P22 PS • RO C H / Q -, S3 K] _ t}EBB/BL ' 60 K ®PMH e}289/GY Q K6 ir YEL I le LNK f3lB { ( • L T III O 23]/BR S KS P. UCH 13]/PR ® 1© 101/ n CONPR22 �, KI ■ 129/BR2�® ]03/BLS®[�.�\ELK{f303/Y-� K3 0©Q 13/ T -E139/0 ©12?® - 106/0 4v {f302/Y S N2 Q©O 247/BR Al - 130/PR OAT C 0 Q S = 2)-216/D H% i0 MI-Ll TD MI-L3 Id 1SELO CON FC- `' IIII Ir3�--a SEE BETAIL A MD Pk ® 4}232/Y m VOLTAGES �K-�BLK—yy�r 178/0 11 H 230V eau SI —� 6 21]/0 121A PRIV T1 113-2 BI.N BLK ®,i{'®1]9/0— -r IN ' ]-214/BL LP' i -- 21 VSEAc - 28]/HR -- B3-1 ram. toh FS 387/R�347/• re © B}215/13L o REO }100/BK I i ;' R oC- - - '}10VHK—C 208V ui a 230V PRI r V 7 TH3�2I0/HR Jl3 �^ 12 TB3-2 I --� - N CO SA HIS H I 0' _Jr 2 C 810 15 : • 0 50/Rt ,,.. ..,,w u` TO OPTIONAL HELD 206/Ht -121/1 HI 130/PR PRI 7 OIB _ C INSTALLED NETSTAT S 3.]3 aP 5 A ♦y E 0 ®®EICI®e©CIElli , 1 1 H y �5 VA - 22 R(J ]%DETAIL2�A 3]5 am' 2]5 3PC T2 �� • I I 3l5 AW '=-. /"1TH3-3 Rai ® PNS YY CAUTION-OPEN ALL DISCONNECTS 3 2I/R -r T-w-1I 0 BIB R vi BEFORE SERVICING THIS UNIT. = G5829895A REV A SHT1 OF2 Io Q 6 3 N QAC U- £ . , 1183509-UIM-O-0618 DANGER- SHOCK HAZARD TURN OFF ELECTRICAL POWER BEFORE SERVICING TO PREVENT POSSIBLE DAMAGE TO THE EQUIPMENT AND POSSIBLE PERSONAL INJURY. CAUTION TO PREVENT ELECTRICAL SHOCK OPEN FAN REMOTE DISCONNECT SO ELECTRICAL MOTOR SUPPLY TO AIR CONDITIONER IS SHUT OFF. RED / COMPONENTS SHOWN IN DASHED // °R LINES ARE OPTIONAL. BRN o S Co O BLACK WIRE WILL BE REMOVED IF LOW GRN\ BLK AMBIENT KIT IS INSTALLED. oGND 3O WIRING MUST CONFORM TO NATIONAL AND LOCAL CODES. 0 IF ANY OF THE ORIGINAL WIRE ww Z —_ SUPPLIED WITH THIS UNIT MUST BE CC co COMPRESSOR REPLACED,IT MUST BE REPLACED WITH TYPE 105°C.THERMOPLASTIC ° FC Ti \ OR ITS EQUIVALENT. T3 T2 HPS -HIGH PRESSURE SWITCH CCH LPS -LOW PRESSURE SWITCH CCH -CRANKCASE HEATER p 1n� o HS -HEATER SWITCH CC -CONTACTOR COIL J J FC -FAN CAPACITOR 00 CO Z y Y CC J J w w m CO CO CC CC O y HIGH VOLTAGE FACTORY WIRING LOW VOLTAGE FACTORY WIRING HS....J OPTIONAL WIRING — — FIELD WIRING,LINE VOLTAGE • m J BLU CONTACTOR 0a y ° T3 1 L3 L2 T2 Ti 11 L1 �� } O yw0o BLU GND LUG I I J ro 208-230 VAC 60 Hz 3 PHASE SUPPLY y 460 VAC 60 Hz 3 PHASE SUPPLY Z} HPS 575 VAC 60 Hz 3 PHASE SUPPLY USE COPPER CONDUCTORS ONLY }0 GND 0 o JUNCTION BOX 24 VAC CONTROL CIRCUIT (20 VA MIN.) 5203528-UWD-A-0416 FIGURE 22:Wiring Diagram-Three Phase 13 Seer Johnson Controls Ducted Systems '� v • 03 N co I A I B I C I 0 I E I F I G I H I J I K I L I 0 4 PIPE CONDENSER UNIT 208- 230V CAUTION -1i/9PEN ALL DISCONNECTS BEFORE SERVICING THIS UNIT ELEMENTARY DIAGRAM (Q FACTORY WIRING AND DEVICES I79/0 Il!/• 0 D31 TO_MI-AUK-NC-&-1211R -I 1-0-1 - O __••—OPTIONAL WIRING AND DEVICES PRI-I Caw0 ONO! FIELD WIRING 20eV ® POWER SUPPLY -- 1vT.�VY-"LN ]I 106/R-{]fUl[�-10!/R �1 IOOIBK �1 LUG( rt 292/R 0 O 230Y 208/230-3-R0 — '` it, TO_CCNI- — i YI-2 ® 0 �I• UEBEBP i92/ RYI-I C USE COPPER ____ �BLX— -- +. 101/BR{]FU2 C}-104/BR i�101/BL('. 4 MI TB2 TI CONDUCTORS �1 MI-3 _ CI') AUK [SIxlCi CCH A7FPLIARY 0 0 Q. i51IB OXLI ____ `''\�LX—.. }�� IsI to-C)sA I�105/0�1 �I Of/x I€ RCi-2 Cxi-4 „,,SEE Q FYI-4 ODOR, INDOOR FAX 293/ \ 116/B 15 YA 3.75 AMP l PRI-2 `[LAY, DOOR FAN t'/1 O 260IBL-SQI c`_- UI-li VS E.DUAL ELfY[XT,CDYPgE SSOR Pq2-I -- f TO-YZ-AUK-NC-B-1211 M2-1 N FU13-24 NU:OVAL EL ENWXT,OD FIX NTR 294/R TO UCB-C COMPR•2 Q FY25.26 FUSE,CONTROL CIRCUIT O _ Ie9/R--- U25E)—'16e/ 115/R—(]fU4 C�II2/R H IRO/BR NGSI HOT GAS BYPASS VALVE I (OPTIONAL] 2621 32 - 221IR .• TO_CCN2-B-6LK Y2-2 vI NI!: HOT GAS BYPASS YALVE 2 IOPTIONALI RY3-I 222/ 208V 116/BR{]FU5[}-113/BR 110/BL f. 0 -2 SWITCH,LON PRESSURE A[ ® ,•• '�Y t.4 CONTACTOR, TOW COMPRESSORS 2/5/' I© 263/BN 33 23av M2-3 NI.1 CONTACTOR CUTDOOR FAN qy1-2 C 19110�)U26 90/• • Illl fUl P151-e CONTACTOR,PHASE FAX TROTORS IORDL E�I Oj� [�I14/0--©i �111/r v 5 OXITOR,PHISE LOSS(OPT IDN All 21•/R-01 I O 265/GI 34 - T2 PSI-2 SWITCH PUNPMT iRl-1 /� 5193 RFLAY.,OUTDOOR PRESSURE 21V SEC YS-I fMl / 3 fLTY,OUTDOOR FIX STAGING 229/A I 0 261/Y CO, -e 250 VA IS AYP I • IIi/' • �� 139IR 1361Bx �]1 O AA`edl RELAY;HOT GING AS BYPASS I IMTIONAL, I , �5 FA2-i / 230/R-{i�i I Q 264/ G2 E ^• 113/B' �0 IIOIBR-©-I -13T/B' �.JC� Q S2P2 SOPI CKET IPEUG CONN.US COXX,CORI LTEMPS iF YPS —2eT/eR�XD3 11, 5! a S3/P3 SOCKETIPLU6 IR SEAT COMTROI 111/Oj)(f UI��141I0�-� �I]B/Y �]GND SI/PI SOCNf ilPL U6 COXX,SIN,DUCT PRS ,-351/PR A RYe B 342/BR-_I R SSYP! 3 CXEL IPL U6 COXX,YfD I �L - 71 _iG S P9 SOCkETIPLUS CORN RCSSURC S91TCX I —211/BRl [.. 122/P22 SOCKET/PLUG CORN;COYPR/!AX CONTROL 355/BM Q(�O -343IBR--J MI-1 fYz 122/Pti TE RM IN SOCKET/PLUG COXN,01 RTY FILi/AIR PROV PRESSURE CONTROLS 131IR-(�UI6[)-14e/�J 115/Bx jtl M• TBI TERMINAL BLOCK.MAIN PMER DEVICE OP ORATING PRESSURE ./- I AIB-I ^ �' Bi FRY IXAL BL OCX, 0 POLE t1V O51 8-2 I.Q rl iRAX3FMNfR 15Y A,24Y OPEN •/- CLOSE •/- :r-]44/BR--�—3zB/BL--Qi I�T-]SIIO K- J �244/_^'Y T2 TRANSFORMER 250VA,24V HP182 925 25 500 25 RY9-1 0 221/BN ].�',1 212/B A� 152/B'•�e 149/BR-0{ -118/B' Ij'.0 C UBC-Ili UNIT CONTROL BOARDS LP'42 50 5 11 5 I r345/B1--�V`H00S-z—335/BN-0-1 �� Y6-] PSIB2 300 l0 480 10 V vl F\'1341/aN-I- Rr2 I Is3/O-((fule[}-Iso/o-� I-(})-In/Y_ oR R P. -� zsl[ ' ...SISISfl 92N lBN T _ C PXS-I ^' 12/3 A•QUO 121/R M3 1 a/BN COYPRI3 C --1-OU I Y�� 226IR 2zsIBN 1 i0_CCx3-B—BLkII 9 • 125/BD{]FUe C-122/BR .14.3.2 �119/BL f.® 'I ® PSI ].MI I •• . _ L.. .._J I YJ-J • bs R13 126/0-(]1U9 I.)-12J/0-� F0-I 20/YLa MIN 4 I_I I I i [ I I H I I 252/9Q-I Q R2 e : ®BS RI X: ^ : >; ry TO-NI-TUC-MC-E—li lR� COYPR91 ... 321IPR{B �•„ P• PPP «0 325/PR{e r4 Pt3 „« n u • 1331 •�, 130/R ,(42�121/BX .+ 103/0— I.v. RY4-1 e: TO_CCMI-B—OLk NI-2 J10/PR{1 �•„ J21/PR{l 21J/ 9 6 21a/Bx I]1/B' �� 131/BR La 1 C6 NY I. 211/B0 C6 AT 259/BX 1 •• 1351 U12 132/ 4! 129/Y (s .N `� --()MI CX`,,z1zlSS �s NF MI -1 �5' D—C 1� D--©M FI iNnh-319/0� - {I N�Y2Jb/BR— 32J/0{I '--(_)\Q-2 ss/ex ].m']1 ry 3/5/o-�3 • - o_I I 3zz/o{i s 0z \ ©BRN �Ml�� FN3 I60/RjU19C r151/ \YI nLY lsuen D 20e/R o(A]PAI[B]-220/BR I� PHS- M7-2 �2 N4 (Z KS x4 2) 206/R{AIPR22�BR G •. 161/BR(1U2Gjr158/BR-{1I�155/B' �j. N:L1 52II 3�201/R - I(AI1RI[Bx219/BR, S2_ NA 3}-209/R{AIFR2CB)A26T/BR 162/0j]FU21[r15Rn-0d �156/T If 1849-2e4/Y{6 NS (2204/R 1AIRY2[B'✓ Z.•zssio-6 }-210/R IRY4[8)266/BRJ �GRR 283/C 5 0. z35/B 2B5/I 5 5 iJ32 A 12Y]CB i3T/BR PP Z Px5 NB-1 fN1 { • 5 200/R 0gYI B �� { w� I ) ITV.... -- • I61/R-(Sun()-16•/R—QH 1- 163/BN I• �4 1 r_� -I 236/BR !4 _ SI 2 -202/Y(IN1}23938/BR- Ol-O • Yb-2 c l \3 LOOM I. Yc• N 2�—Z6B/ J `(3 r p iA3)1'OLK- __• 110/B'��]� 167/BR�B I�IG4/B'�j'.3�1 0 S S S S •a�� 3� C2 L5D ii is IBl C 3 —205/•2��� 11.LN • Ili/. • 2�• 16B/0--Q-I I�I65/Y III®_I .� I�2BfIBL _ '-�g( 4)-1 90/Y/Y 291/GY [[HI J� 4'GR 51I ' HPI 31_. J )— MP2 LX-((III�BLK—r0_w1-L2 = ...$ F-�---' �9 ' LO[FIAILID 1091 RN NB 10 BE ACC011Px1 EPPD OLLORINF Clii, UCB I 0 s}z11/ UCB-2 -101 � 0'4"v NI-TUC AL m NA cgEs &P of �b '--, ly }218/BL =„ H �247/C T2T/R—TO_111,1 INSTALLATION O HIS UNIT. — on I LPI B I LP2 CCN2 p.CAUiIM:LABFLF AI NI RESTPRI OR i0 DISCONX[Cild1 �215IBL „ N 1.249/Y 11TT1 MPP PERY^XOMO COEROOSSo R NG ERROAM CAP iMESE F'B LN ^LK�TO_M2-L2 0 ER ANG P[ TNi 1u w ,8• 8}z14/BL U. 8,250/GC Pig1 U.1 BC AE PL95<EO Pi iP T E OS OE SRE CF FREMO r� \�_ M2-AUC V Li RE LEML CLEARLY NUMBERED ER60 A Y 9� B S 9} 21 O_Y2-LI DFNTgI lox.UVE RIFY PROPER OPERATION AFTER O[D Z. u I�S } I)--4 CCH3 6[RY IC IN6. -- --RED---- CCxI -CCx4 LNF'B (III F--BLK—i0_YJ-US 3'YMP[R PRIYIRY SIMXOLERVNAPE F[OPDii10PSTECTFO : lp—:5:00:::: - . I'€- ARE GROUNDED N3-AUCKr_ 4. EF T x w1SE A D oR clRtuli • itl/R—i0_MJ-LI BREAPERMEPX41x X U1:11112VA1YPA51iY.^' �� ;1I;". '•_ ry �� B2BCBBCC9: ,1"[en[2.� CCHI X ® CTOPxTS PH ASELOSS OMONITOR0 OPERATION. R WIRE LN�IIII�—eL—TO_YI-L2 2C I:O FO TO [E-IM-TEIOV ®F RY•IRA R UNITS, M4-AUf 116/R TO_YI-LI PMIOYF PiRE=8 TO;SD'Pi[RMIPAL al TY.aV iv 'E 'E TO_TI-SEC-CON ®TRIM FVAP ux17:WIRE FROM TB2(GI TOM FOR 53/BR 41R/BA I G 5 4 8 38 I 0 A REV . A 1.DISMIE LGD/l A•M UN COX TRO BOARDS 1f OOM 1 8 2 C7 IRE Iki,1 ED. L n-H 1 o_ G) `G N O_ m CO JB14 OREGON Submittal Unit Written Specification 735 SW 20th Place 230 , Portland , OR 97205 PHONE (971) 717-7123 la 505429-JTG-HH-0620 ACU-1 , AC U-2, AC U-3, AC U-5, & ACU-6 Guide Specifications Split System Cooling Only Condensing Units Models: J07 through 25YC, J10 through 20YD, JO7YE and Split System Heat Pump Models: J07 through 15PC, J15 through 20PD, JO7PE General • Factory assembled,single piece,air cooled condensing unit designed for outdoor installation. i • Factory wired, piped, and tested for leakage and functionality to assure trouble-free installation and start- up. • Rated in accordance with AHRI Standard 340/360. 'f • Designed and tested in accordance with ASHRAE 15 Safety Code for Mechanical Refrigeration and comply with NEC. fj • Cooling performance rated in accordance with DOE and AHRI test procedures. • CSA listed and classified to UL 1995/CAN/CSA No. 236- M90 standards. • One year limited parts warranty on complete unit with an additional four year compressor warranty. Unit Operating Characteristics { Operating Range shall be between 125°F to 40° F in cooling as standard from factory. j Johnson Controls Ducted Systems 1 505429-JTG-HH-0620 Condenser Fans • Direct driven propeller-type fans • Aluminum blades riveted to corrosion resistant steel spider brackets. Installer Shall • Arranged for vertical air discharge. • Furnish Johnson Controls air-cooled condensing units, • Equipped with PVC coated steel wire safety guards. heat pump or equivalent in accordance with the performance schedule shown on the plans, and Condenser Motors • Unit shall be stored and handled in accordance with unit • Totally enclosed, air over cooled. manufacturer's instructions. • Inherent overload protection. • Install each unit as shown on the plans in accordance • Permanently lubricated bearings. with the manufacturer's recommendations and all • Must cycle to allow cooling operation down to 45°F. applicable national and local codes Unit Construction Refrigerant Piping • Constructed of zinc coated,galvanized steel. • Solid core filter-drier(s)ship loose for field installation. • Exterior surfaces bonded and coated with baked • Liquid and suction line service valves with gauge ports. enamel finish by a powder paint process capable of • Suction and discharge line service ports accessible withstanding a minimum of 750 salt spray hours from unit. Ports capped for leak prevention. according to ASTM B117. • Liquid line magnetic check valves • Cabinet screws that comply with ASTM B117 salt spray • Holding charge of R410A refrigerant. test for a minimum of 750 hours. • Permanently attached heavy-gage perimeter base rails Electrical Requirements with forklift slots and lifting holes. • Single-point connection electrical power. • Removable access panels to all internal components. • Nominal unit electrical characteristics shall be v, • Separate access panel to controls. 3-ph, 60 Hz.The unit shall be capable of satisfactory • Access panels to allow outdoor coil cleaning. operation within voltage limits of v to v. • Condenser fan motors and secondary of transformers Compressor(s) shall be grounded. • Hermetic scroll type, internally protected with high Unit Controls pressure relief and over temperature protection. • Two stage units operate in 50%capacity increments. • All 24-volt control circuit, powered by a 24 volt • Suction gas cooled transformer(s)and protected by a resettable breaker. • Voltage range of±10%of unit nameplate voltage. • Conventional thermostat must provide operation for both condensing units and heat pumps without an"O" • Neoprene isolators minimize sound transmission and output from the thermostat. vibration. • Low voltage terminal strip for simple hook-up. • Belly-band crankcase heaters keep refrigerant from diluting sump oil. • Compressor motor protection shuts down unit for motor over-current, over-temperature or low voltage • Full charge of compressor oil conditions. Outdoor Condenser Unit Coils • Safety lockouts provide reset capability at the space thermostat or base unit should any of the following • Draw thru configuration standard safety devices trip and shut off compressor: • Constructed with Micro-channel aluminum fins and a. Loss-of-charge/Low-pressure switch. aluminum tubing. b. High-pressure switch. c. Control board diagnostics and fault message display. d. Safety lockouts send a 24 volt signal to the control board's "X" terminal, allowing notification to the user via the thermostat fault light(if present). Johnson Controls Ducted Systems 505429-JTG-H H-0620 e. In the unlikely event any faults should occur, the unit • In current production with published literature available control board will store the faults in its internal to check performance, limitations,specifications, power memory. The LCD display will scroll the 5 MOST requirements, dimensions, operation and appearance. critical faults, however, all fault messages can be extracted via USB device, displayed real-time via the • Indoor unit shall be equipped with a V-belt drive option MAP Gateway as well as be broadcasted through a that will permit the blower RPM to be adjusted to meet BAS system (if applicable). The UCB will provide fault the CFM requirements of the air delivery system.(Refer messages in plain English to ensure the user can to Technical Guide for Airflow Capabilities.) easily understand the specific fault. Each Unit Enclosure Shall Have: Non-fused Disconnect Switch • Exterior panels of 18 gauge steel,finished with baked • Factory-installed, internally mounted. enamel to provide a long lasting quality appearance • Accessible from outside the unit. • Removable panels to provide easy access to the • NEC and UL approved non fused switch. internal components for maintenance and service on condensing units, heat pumps and air handlers • Provides power off lockout capability. • Air handling units must have a filter rack that accepts both 2"and 4"filters(7.5-20 Ton only). • The dimensions of each unit shall not exceed those specified in the manufacturers literature. • The minimum application clearances for condensing units, heat pumps and air handlers must meet those specified in the manufacturer's literature. Coil Guard Factory or field installed decorative grille shall be placed on the units to protect condenser coil after installation. Each Unit Shall Be: • Covered by a 1-year limited parts warranty on the complete unit and 5-year on compressor(s). Johnson Controls Ducted Systems 5293151-UTG-B-0217 MECHANICAL SPECIFICATIONS • Units shall be factory leak checked, run tested, and shipped MANUFACTURE AND CERTIFICATIONS with a holding charge of R-410A refrigerant. • Units shall be manufactured in an ISO 9001 certified facility. • Unit cabinet components shall be G90 equivalent steel fin- • Units shall be certified by CSA to UL 1995 / CSA 22.2 and ished with powder coat paint rated at a minimum of 500 performance certified to ANSI/AHRI Standard 210/240. hours underASTM B117 testing. • • Units shall be sound tested according to ANSI/AHRI Stan- Unit base pan shall be stamped G90 equivalent steel fin dard nit 270. ished with powder-coat paint rated at a minimum of 500 hours under ASTM B117 testing. • Certified matched system ratings will be available for down- load from the AHRI online directory at www.ahridirectory.orq • Units shall have a single corner post opposite the electrical control box and two indepedently removeable steel coil • Unit packaging shall be marked, "Assembled in the USA" guard panels to optimize cabinet strength and serviceability UNIT APPLICATION • Units shall have L-shaped stamped sheet metal coil guards • Units shall be approved for linesets up to 80 feet equivalent with extruded slots for maximum panel durability and stiff- length without modification. ness. • Units shall be approved for installation within 6 inches of a • Units shall have a factory installed filter-drier for faster instal- flat vertical wall without modification, according to the lation and improved system reliability. instructions in the technical literature. • Units shall be constructed with a high pressure switch for • Units shall be certified to the 5th Edition (2014)of the Florida system protection. Building Code for a combined allowable lateral and uplift . Units shall be constructed with all badging and labels applied wind force of 200 psf and 100 psf, respectively, for both at the factory. ground-mounted and rooftop-mounted applications up to 200 feet above grade with approved mounting kit. UNIT COMPONENTS • Units shall be designed to 77 dBA or less to minimize sound • Compressor shall be hermetic with internal electrical over- pollution. load protection and internal overpressure protection. UNIT ACCESS • Compressor shall be mounted on rubber vibration isolators that do not require the removal of transportation clips or • Units shall have a removable fan guard that can be removed brackets. independently of the top for interior access through the top of • Units shall be constructed with internally sprung reciprocat- the unit without damaging the coil. ing compressors for low vibration. (Applies to select models). • Units shall have two removable stamped steel coil guards for • Condenser fan shall be direct drive with vertical air discharge exterior coil access. for low sound levels. • Units shall have a separate compartment for electrical con • Condenser fan motor shall be totally enclosed with perma- trols that can be accessed without disturbing the unit airflow. nently lubricated ball bearings motors approved for vertical • Units shall have a blockoff panel that can be removed to pro- shaft applications. vide interior unit access through the side of the unit. • Condenser coil shall be air cooled and constructed of zinc- • Units shall have a removable blockoff panel and a swing coated aluminum microchannel construction for small size away removable electrical panel that provides sufficient inte- and low weight. nor unit access for removing the compressor through the side of the unit. UNIT WARRANTIES CONSTRUCTION • Unit manufacturer shall provide a 5-Year compressor war- UNITranty without a requirement for unit registration. • Units shall be shipped completely wired, piped and aysem- • Unit manufacturer shall provide a 1-Year parts warranty with- bled. Wiring pigtails shall be provided for field control wiring out a requirement for unit registration. connections. Service valves shall be provided for field refrig- erant line connections. Johnson Controls Unitary Products 628791-JTG-H-1019 Guide Specifications THE DIMENSIONS OF EACH UNIT SHALL: SPLIT SYSTEM COOLING ONLY CONDENSING • Not exceed those specified on the plans. UNITS EACH COMPRESSOR SHALL: MODELS J30YD, J40YD AND J50YD • Be mounted on isolators to minimize the transmission of THE INSTALLER SHALL: vibration. ALL CONDENSER COILS SHALL: • Furnish Johnson Controls air-cooled condensing units or equivalent in accordance with the performance schedule • Be draw through design. shown on the plans, and • Be constructed of copper tubes arranged in staggered • Install each unit as shown on the plans in accordance rows and mechanically expanded into aluminum fins. with: THE CONDENSER FAN MOTOR(S)SHALL: • The manufacturers recommendations and • All applicable national and local codes • Be directly connected to the condenser fans. EACH UNIT SHALL BE: • Have permanently lubricated ball bearings. • Have inherent overload protection. • CSA approved. • Motors shall be three phase. • Completely assembled for one-piece shipping and rig- ging. • The propeller-type condenser fans shall be arranged for vertical discharge of the condenser air. • Leak pressure and functionally tested at the factory to assure a trouble-free start-up after installation. THE WIRING FOR EACH UNIT SHALL INCLUDE: • Covered by a 1-year limited parts warranty on the corn- • A crankcase heater(one per compressor) plete unit. • All 24-volt temperature control circuit. • In current production with published literature available to check performance, limitations, specifications, power • Both high and low pressure cutouts. requirements,dimensions, operation and appearance. • Solid-state or internal line break compressor motor pro- EACH UNIT SHALL HAVE: tection. • • A steel angle frame to provide the rigid support required Condenser fan motor control to assure stable operation for shipping, ri in andyears of dependable operation. at ambient temperatures down to 40°F. rigging p P • Zinc-coated steel that has been finished by a powder THE REFRIGERANT PIPING of each system shall include: paint process to provide a long lasting, quality appear- ance. • A filter-drier shipped for field installation. • Removable panels for easy access to all internal compo- nents during maintenance and service. Ducted Systems • j810, OREGON Submittal Warranty 735 SW 20th Place 230 , Portland , OR 97205 PHONE (971) 717-7123 • 65711-UWA-C-0413 Limiter-Warranty Wilig;a647420.1111 .41 Unitary Products warrants this product to be free from defects in factory workmanship and material under normal use and service and will, at its option,repair or replace parts proved to have such defects provided in the table below.Time periods are measured from the date of installation or,if such date is not determinable,from the date of shipment of the product from the factory. Hermetic Compressors 5 Years Standard Evaporator or Condenser Coil 1 Year Electro Fin Evaporator or Condenser Coil 3 Years All Other Parts 1 Year For your benefit and protection,return the warranty registration card to Unitary Products promptly after installation,or register online at www.upgproductregistration.com. This will initiate the warranty period and will allow us to contact you, should it become necessary. In the absence of a recorded warranty,the warranty period will begin upon product shipment from the fac- tory. This warranty extends only to the original consumer purchaser and is non-transferable. For this warranty to apply,the product must be installed according to Unitary Products recommendations and specifications,and in accordance with all local, state and national codes, and the product must not be removed from its place of original installation.The warranty period for repair or replacement parts provided hereunder shall not extend beyond the warranty period stated above. This warranty applies only to products installed in the United States,Canada or Mexico. EXCLUSIONS This warranty does not cover any: 1. Shipping,labor,or material charges. 2. Damages resulting from transportation, installation,or servicing. 3. Damages resulting from accident,abuse,fire,flood,alteration,or acts of God.Tampering,altering,defacing or removing the product serial number will serve to void this warranty. 4. Damages resulting from use of the product in a corrosive atmosphere. 5. Damages resulting from inadequacy or interruption of electrical service or fuel supply, improper voltage conditions, blown fuses,or other like damages. 6. Cleaning or replacement of filters. 7. Damages resulting from failure to properly and regularly clean air and/or water side of heat recovery core. 8. Damages resulting from freezing of condensate. 9. Damages resulting from operation with inadequate supply of air or water. 10. Damages resulting from use of components or accessories not approved by Unitary Products(vent dampers,etc.). THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. SOME STATES DO NOT ALLOW THE DISCLAIMER OF IMPLIED WARRANTY,SO THAT THE ABOVE DISCLAIMER MAY NOT APPLY TO YOU. SOME STATES ALLOW ONLY A PARTIAL LIMITATION ON IMPLIED WARRANTIES TO LIMIT THE DURATION OF IMPLIED WAR- RANTIES TO THE DURATION OF THE EXPRESS WARRANTY. IN SUCH STATES, THE DURATION OF IMPLIED WARRANTIES IS HEREBY EXPRESSLY LIMITED TO THE DURATION OF THE EXPRESS WARRANTY ON THE FACE HEREOF. IN NO EVENT,WHETHER AS A RESULT OF BREACH OF WARRANTY OR CONTRACT,TORT(INCLUDING NEGLIGENCE)STRICT LIABILITY OR OTHERWISE, SHALL UNITARY PRODUCTS BE LIABLE FOR SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAM- AGES, INCLUDING BUT NOT LIMITED TO LOSS OF USE OF THE EQUIPMENT OR ASSOCIATED EQUIPMENT, LOST REVENUES OR PROFITS, COST OF SUBSTITUTE EQUIPMENT OR COST OF FUEL OR ELECTRICITY. THE ABOVE LIMITATIONS SHALL INURE TO THE BENEFIT OF UNITARY PRODUCTS SUPPLIERS AND SUBCONTRACTORS.THE ABOVE LIMITATION ON CONSE- QUENTIAL DAMAGES SHALL NOT APPLY TO INJURIES TO PERSONS IN THE CASE OF CONSUMER GOODS. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAM- AGES,OR FOR STRICT LIABILITY IN TORT,SO THAT THE ABOVE EXCLUSIONS AND LIMITATIONS MAY NOT APPLY TO YOU. UNITARY PRODUCTS DOES NOT ASSUME,OR AUTHORIZE ANY OTHER PERSON TO ASSUME FOR UNITARY PRODUCTS,ANY OTHER LIABILITY FOR THE SALE OF THIS PRODUCT. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS.YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE. (OVER) Johnson Controls Unitary Products r TO OBTAIN WARRANTY SERVICE Notify your installing or servicing dealer, preferable in writing, of the problem as soon as possible after its discovery. Be sure to include product model number,serial number,installation date and the nature of the problem. If a response is not received within a reasonable time,notify Unitary Products Customer Relations Dept.5005 York Drive, Norman,Okla- homa 73069 U.S.A.Service requests sent to Unitary Products without prior dealer contact will be referred back to a dealer through the Distributor of Unitary Products products. Because this is a time consuming process, it is in the best interest of the consumer to contact a dealer directly. For Owner's Information only.In no way does the information below constitute any change in warranty period or policy. PRODUCT MODEL NO. INSTALLATION DATE UNIT SERIAL NO. INSTALLING DEALER LEli ,)))41r Johnson Controls Unitary Products 5005 York Drive,Norman,Oklahoma 73069 o h n so n Copyright©Subject to change without notice.Printed in U.S.A. 2013 by Johnson Controls Inc.All rights reserved. Controls 65711-UWA-C-0413 Supersedes:65711-UWA-B-0912