Plans LIABILITY RECEIVED
i. r ,j of Tigard and its AUL 19 2021
1 :I-Ve ?S shall not be Kemena Residence CITY OF TIGARD
Photovoltaic Installation Electrical Diagram
��;�,;1Y'�S�k:+ f' �t?� d=screpancie� g
herein. Rated 8.05 kW under standard test conditions 3UILDING DIVISION
R.$ 3 #33 #t _.>-.3.$' :I.#.$f. }£ # L 3 3-#A3 € i_ i ac T c „� } 3 er 3#�+ :$-3E
ACJunetlonY at „s•^ f. r n d 1 £-#€. 14 a,x3f € x--=, a :-.s-�n �,�,s.�'`3 # c ax et a b-.-
Box r .. c:t. _ ' a *y¥ 3^ems." :ice `t ". ..,€ } r„ '.�^�,�ti in
ir"cable . > �) �� , Approved plans
Enphase Engage"trunk"cable f-,l.}.!! be on job c,!t,OyA••
4 s s€:££ € } ¥ z a¥}} } a f a fit + € # asR•� f ria x a} -.} rr ` •,ti 4 #
AC Junction 3 } 3,,, v�r} tm:,, '.` } }r dY xfx 4 } ,> v f is€ !. s, : xs I :3 t£ t 9
Box � #sl t° `�;�� } � �t �� '�} �`�t`1.. ��, � �����`"`r:) AC Voltage Drop:
min ., r $- �:. Section1(Q Cable)
OFFICE COPY 12 inverters=1.59V drop
Enphase Engage"trunk"cable +
Section 2(to Combiner)
.. .✓:k i g -.w°#:,, '" 1-` Suf i r - - . (1.21 x 12)x(0.00124)x 120=2.16V drop
` - - Section 3(Combiner to PCC)
12_' ISSUANCE OF A PERMIT - (1.21 x-23)x(0.000778)x 20=0.43V drop
#10
THH BASED ON CONSTRUCTION CITY OF TIGARD =u,L2, - 4.18V Total Drop or 1.74%
ge DOCUMENTS AND OTHER REVIEWED FOR ODE COMPLIANCE
DATA SHALL NOT PREVENT METER
project Name
�� THE CODE OFFICIAL FROM o°o Approved: [ Kemena Residence
sl Conductors in REQUIRING THE CORRECTION OTC: (( (23)System a SpePanasonic
350iove
of N"EMT Conduit l 1 (23)Panasonic 350 Evervolt Modules
o" #t° OF ERRORS.ORSC 105.4 �AG /-�
THHN Permit#: I r�(J� � ' UV(--9 (23)Enphase IQ7+Micro-Inverters
I Ground
�.�_ � nnbdules grounded to racking system
Address: /I J l'L1 JUJ Aj'� _' - - J J through Ironridge Integrated grounding
o _o C 1
Two 20A 2-Pole O r—°° f#GroundN Suite #: Iron Ridge Rails&Mounting Hardware
Breakers J�
i
0, Y° 0 By: �1)r- Date: �7 74 Aluminum PV Flashing with SS Hardware
- #B THHN • ,1
Neutral
/ 200A Main
\/t�\/t - • —'� Breaker
0 O
#8 THHN
f 1 ) 11,c2,in5'of r•sn*a,, ng Bonding all rails together
Rs
VietAEM Lugs Enphase/IO ,p cx O1 O
Combiner Panel , ^
IIIIIIIIMIMM _, O 00 00
60A Fusible Module Specifications: Inverter Specifications:
#8THHN AC Non- 2P40A� imn meter#O*
11,L2,in o;:connect Breaker Evervolt EVPV350K Enphase iQ7PLUS-72-2-US
3 .
s of 3• Pmax: 350 Watts Compliance:UL-1741,IEEE 1547
pvc Vmpp: 36 V Max DC Input Voltage: 60Vdc
Contractor: Customer: Voc: 43.2 V Max DC Short Current:15 Amps
` Nicole Kemena Impp: 9.73 A Max AC Output Power 290 Watts
AI, Solar NW Nominal Output Current:1.21 A
Three Line Drawing 12399 NW Waker Dr. 7844 SW Ashford Street !so: 10.44 A
Max Series Fuse:25A Nominal Voltage Range:240V/211V-264V
Tigard OR 97224 Max System Voltage:1oo0V
PREMIER S O LAR Portland, Or. 97229 916-494-8794
July 9,2021 Max System Voltage:
1000"
Weight:43 lbs.
NORTHWEST
Legend: Kemena Residence
• =Sun Eye Reading Location
Scale 3/32" = 1' x
X=Does Not Qualify for ETO
}
200A Meter
} --�
Main
AC
o Less Than12"from Any Ridge Disconnect
iiirCombiner
Panel
0
ts)
lie.
65'
(23) Panasonic 350H H 461"I' 1
Evervolt ModulesIF
2019 OSSC `
w/(23) Enphase IQ7+-72-2- 0
US Inverters 2019 OR Firecode
ri
Roof Mounting Datail:
Mounting Notes
1. 2x8 Rafters @ 24" O.C.
2. Roof penetrations: 24 48" O.C. `a N1odu�e
3. Composition Roofing %
4. Panel height off roof< 12 inches7;°------------
\...----
5. Weight of PV modules and assembly
\___
less than 4.5 lbs per sq. ft. qi
6. Azimuth: 180° & 270°
Iron rid XR100 Rail 'R,.
7. Module Tilt: 36° g
"`
8. Integrated Grounding Hardware 6 ruches
9. All installations comply with rr
manufacturer's installation instructions
10. All horizontal ridges kept clear of PV . V. *SO.-'s,44***74;;;: , 44*.'—:
components at least 1 ft. either side • • •ii ` y,
11. PV array to cover less than 25% of total `
roof area , -
12. OSSC 3111: Attachments shall be °��,
spaced no greater than 24" O.C. in any
direction when located within 36" of a roof
edge, hip, eave, or ridge. 5/16"X6"SS Hanger Bolt
13. Solar array not to exceed height of any 3" Lag thread for 2.7"Thread
horizontal ridge line. penetration in to roofing member
Total Roof Area: 2,745 sq. ft. July 9,2021
Total Solar Area: 362.25 sq. ft.
Solar Covers 13%of Roof Area Nicole Kemena
7844 SW Ashford Street
EQUIPMENT
Tigard OR 97224
916-494-8794
t (23) Panasonic 350 Evervolt Modules - -
GENERAL CONTRACTOR:
AL, C&B RENEWABLE ENERGY,LLC
(23) Enphase IQ7+-72-2-US Inverters
12399 NW WAKER DR.
Iron Ridge Mounting System PORTLAND OR.,97229
PREMIER SOLAR 503 828-9500
CONTACT:
CLIFF CLIFF BARRY
� T.. Aluminum PV Roof Flashings
Kemena Site Plan
Layout 11"X 17"
Roof Structure&Site Map
Scale 3/32"=1"
SW Ashford
27'
h >
s �
a wa
rre
d a
�
z
w
(J V
111
O p
Q Q
20'
ADJACENT PROPERTY
75'
Contractor: Customer:
GENERAL CONTRACTOR: ��
C&B RENEWABLE ENERGYLLC Nicole Kemena
PREMIER
�`y [ �} p 12399 NW WAKER DR. 7844 SW Ashford Street
1 RElvtt E R SOLAR PORTLAND OR 97229 Tigard OR 97224
NORTHWEST 503 828-9500 916-494-8794 Plot Map July 9,2021
CONTACT:CLIFF BARRY
Kemena Site Plan
Roof Structure&Site Map
Maximum span per
Table 2308.7.2(1)is 12'
10"for#2 2X8 Douglas
Fir Larch at 24"OC
Solar array not to exceed
height of any horizontal ridge
0
y N
#1 2X8 Rafter 24"OC
i0
e4
I ,
',Ark Contractor: Customer;
GENERAL CONTRACTOR:
C8B RENEWABLE ENERGY,LLC Nicole Kemena
12399 NW WAKER DR. 7844 SW Ashford Street
PREMIER SOLAR PORTLANDOR.,97229 Tigard OR 97224
NORTHWEST
£ 503 828-9500 916-494-8794 Structure July 9,2021
CONTACT:CLIFF BARRY