Permit CITY OF TIGARD MASTER PERMIT ■ COMMUNITY DEVELOPMENT Permit#: MST2021-00291 13125 SW Hall Blvd..Tigard OR 97223 503.718.2439 Date Issued: 08/02/2021 t"�R D 9 Parcel: 2S112CA07500 Jurisdiction: Tigard Site address: 7844 SW ASHFORD ST Subdivision: RENAISSANCE WOODS Lot: 1 Project: Kemena Project Description: 8.05 kW rooftop solar BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $24,700.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 1 0-200 amp: 0 W/Svc or Fdr: 0 Ea addl 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Roof TopSolar PV System 8.05 kW Ecom N Other Y Other Description: Y pacing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF V B R-3 0 Owner: Contractor: LEE,JAY KYU PREMIER SOLAR NW Required Items and Reports(Conditions) KEMENA,NICOLE THERESE 12399 NW WAKER DR 7844 SW ASHFORD ST PORTLAND,OR 97229 TIGARD,OR 97224 PHONE: PHONE: 503-799-9042 FAX: Total Fees: $473.47 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR Q99-nrN-nin fhrni$nh nap QF9-nnl-nnon YniI may nhfain a rnn,of fhp rnJpe nr Hirprf niicefinne fn nl IMIr by rnufnn FM 9'39 10A7 nr 1 ann 1 )7144 Issued By: }fully 1/csM,le/WAge Permittee Signature: OniArrucatirto Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the iob site at the time of each inspection. Building Permit APPI Cat'OI ECEIVED 'Residential roll OFFICE I'SE ON1.1' City of Tigard JUL 19 2021 Received .-1 i_oo��\ g Z� �v Permit No.:MSTZa 13125 SW Hall Blvd.,Tigard,OR 97223., Plan Ry: g t�� Review I t�/ Phone: 503.718.2439 Fax: 503.598.19etfITY OF TIGARD Date/By: n,` Other Permit: i 1 t Id I7 Inspection Line: 503.639.4175 BUILDING DIVISION Date Ready/By: ® See Page 2 for Internet: www.tigard-or.gov Not :: ethod: i `��� Supplemental Information rr y �ii / " f e,fgy +AIA. ;y- f ;' a ❑New construction ❑D mo elition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑x Addition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the �� �� ,,•.,0 1p � work indicated on this application' g ant ", t : ,' - ;s ay pP ®1-and 2-family dwelling 0 Commercial/industrial Valuation: $ $24,700.00 ❑Accessory building 0 Multi-family Number of bedrooms: • ❑Master builder 0 Other: Number of bathrooms: A6'Y 9 y� ��� , " ^�;z` r��rya �,,, �� � ,�� g ` � � ^; z ; "" / Total number of floors: Job site address: 7844 SW Ashford Street New dwelling area: square feet City/State/ZIP: Tigard OR 97224 Garage/carport area: square feet Suite/bldg./apt.no.: Project name: Kemena Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all r equipment,materials,labor,overhead,and the profit for the - a;j -_g ° r;r * r; i �/t, work indicated on this application. Adding 8.05 kW Roof Top Solar PV System Valuation: $ Existing building area: square feet New building area: square feet h / g.:i.r r i1 � f 4,ii Number of stories: Name: Nicole Kemena Type of construction: Address: 7844 SW Ashford Street Occupancy groups: City/State/ZIP: Tigard OR 97224 Existing: Phone:(916)494 8794 Fax:( ) 3g ,eNew e iy / ", , 's 31Pa� > � , a , j i g Ie , Business name: Premier Solar NW Structural plan review fee(or deposit): Contact name: Robert M. Rathbone FLS plan review fee(if applicable): Address: 12399 NW Waker Dr. Total fees due upon application: City/State/ZIP: Portland, OR 97229 Amount received: Phone:( 503-$28-9500 Fax::( ) E-mail: rrathbone@premiersolarnw.com '` ' -at } ,a / i r r " f'. y Commercial and residential prescri tive installation of «r. P y h/< �� p> fig' 5?' �g Swr f / / /� ; '' '.y% x;�t''Y /� k�,m ,/,, „' rooftop mounted PhotoVoltatc Sotar Panel System. Business name: Premier Solar NW Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address: 12399 NW Waker Dr. Solar Installation Specialty Code checklist. City/State/ZIP: Portland, OR 07229 Permit Fee(includes plan review $180.00 and administrative fees): Phone:( 503-$28-9500 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lie.: 218826 Total tee due upon application: $201.60 Authorized signature: " This permit application expires if a permit is not obtained J., within 180 days after it has been accepted as complete. Print name: Clifford Barry Date: 7/16/21 *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: Description Qty. Each Total Fee for all residential systems combined: $75.00 Renewable electrical energy systems: 5 kva or less 100.70 2 Check Type of Work Involved: 5.01 to 15 kva 133.56 In.Scp 2 n A• udio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: E Burglar Alarm 25.01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 E Garage Door Opener* >100 kva(fee in accordance 2 with OAR 918-309-0040) 552.26 n Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 E Vacuum Systems* >100 kva—no additional charge 0.0 3 Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspection is 66.25/hr 1 charged at an hourly(1 hr min) Inspections for which no fee is 90.00/hr s.ecificall listed(Y2 hr min d ✓ �AH��� 'i'& '�b� ' ��., y1 €i �.s�. .a te- ` �c, Fee for each commercial system: $75.00 Number of ins Subtotal(Enter on Page 1): (SEE OAR 918-309-0000) , awns allowed per peraut. Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls n C• lock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC n Instrumentation ❑ Intercom and Paging Systems n L• andscape Irrigation Control* ❑ Medical n Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ O• ther: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations 1:1Ruilding\PermitsFELC_PennitApp_ELR_ERE.doc Rev 06117l2015 RECEIVED City of Tigard Building Division JUL t 90Z. 13125 SW Hall Blvd,Tigard,OR 97223 CITY OF TIGARD Phone: 503.718.2439 Fax: 503.598.1960 BUILDING DIVISION 1 c A R D Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 7844 SW Ashford Street City: Tigard OR Zip: 97224 Owner's Name: Nicole Kemena Date: 7/16/21 Contractor's Name: Premier Solar NW CCB #: 218826 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ❑ Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? n No OSSC or ORSC for design requirements. Wind Exposure Is the wind exposure C Yes If"Yes", qualifies for "C"or less`. n No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes Q Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 ps or less? structures other than "Yesqualifies for Yes the If prescriptive path. above ❑ No 1 1:/Building/Forms/PhotoVoltaic-Checklist02-01-11_docx Is the construction material wood and does 0 Yes Type of If"Yes", qualifies for the construction qualify Construction as"conventional light E No the prescriptive path. frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. Yes If"Yes", qualifies for the prescriptive path. n No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes", qualifies for 0 Yes the prescriptive path. ❑ No Is the combined weight ® Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance X Yes with Section 305.4(3) of If"Yes", qualifies for ❑ the 2010 Oregon Solar No the prescriptive path. Code? Li Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. U of composition shingle. Is the roof mounted C Yes Connections of solar assembly If"Yes", qualifies for the solar assembly connected to roof No to the roof framing or blocking ❑ the prescriptive path. directly? 2 1:/Building/Forms/1'hotoVoltaic-Checklist02-01-11.docx U Yes If"Yes", qualifies for Is the gauge 26 or less? (1 No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. n No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for n Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? Yes the prescriptive path. ❑ No Is the roof decking of WSP min. t/"thickness, n Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for module to the roof x❑ Yes theprescriptive ath. solar modules p surface. ❑ No 3 1:/Building/Forms/PhotoVoltaic-Checklist02-01-11.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: Panasonic Model Number: EverVolt 350 Listing Agency: UL 4 1:/Building/Forms/PhotoVoltaic-Checklist02-01-1 l.docx