Permit CITY OF TIGARD MASTER PERMIT
■ COMMUNITY DEVELOPMENT Permit#: MST2021-00291
13125 SW Hall Blvd..Tigard OR 97223 503.718.2439 Date Issued: 08/02/2021
t"�R D 9 Parcel: 2S112CA07500
Jurisdiction: Tigard
Site address: 7844 SW ASHFORD ST
Subdivision: RENAISSANCE WOODS Lot: 1
Project: Kemena
Project Description: 8.05 kW rooftop solar
BUILDING
Floor Areas Required Setbacks Required
Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0
Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke
Dwelling Units: 0 Third: 0 sf Right: 0 Detectors:
Total: 0 sf Value: $24,700.00 Rear: 0
PLUMBING
Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0
Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0
Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0
Bckflw Prevntr: 0
Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0
Drywell-Trench Drain: 0 Other Fixtures: 0
Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0
Heat Pump: N Hoods: 0 Other Units: 0
Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0
Furn>=100K: 0
ELECTRICAL
Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits
1000 sf or less: 0 0-200 amp: 1 0-200 amp: 0 W/Svc or Fdr: 0
Ea addl 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0
Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+amp/volt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All
Roof TopSolar PV System 8.05 kW Ecom N
Other Y Other Description: Y pacing:
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
OTR SF V B R-3 0
Owner: Contractor:
LEE,JAY KYU PREMIER SOLAR NW Required Items and Reports(Conditions)
KEMENA,NICOLE THERESE 12399 NW WAKER DR
7844 SW ASHFORD ST PORTLAND,OR 97229
TIGARD,OR 97224
PHONE: PHONE: 503-799-9042
FAX:
Total Fees: $473.47
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work
will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more
the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
Q99-nrN-nin fhrni$nh nap QF9-nnl-nnon YniI may nhfain a rnn,of fhp rnJpe nr Hirprf niicefinne fn nl IMIr by rnufnn FM 9'39 10A7 nr 1 ann 1 )7144
Issued By: }fully 1/csM,le/WAge Permittee Signature: OniArrucatirto
Call 503.639.4175 by 7:00 a.m.for the next available inspection date.
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the iob site at the time of each inspection.
Building Permit APPI Cat'OI ECEIVED
'Residential roll OFFICE I'SE ON1.1'
City of Tigard JUL 19 2021 Received .-1 i_oo��\
g Z� �v Permit No.:MSTZa
13125 SW Hall Blvd.,Tigard,OR 97223., Plan Ry:
g t�� Review I t�/
Phone: 503.718.2439 Fax: 503.598.19etfITY OF TIGARD Date/By: n,` Other Permit:
i 1 t Id I7 Inspection Line: 503.639.4175 BUILDING DIVISION Date Ready/By: ® See Page 2 for
Internet: www.tigard-or.gov Not :: ethod: i `��� Supplemental Information
rr y �ii / " f e,fgy +AIA. ;y- f ;' a
❑New construction ❑D mo elition Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
❑x Addition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the
�� �� ,,•.,0 1p � work indicated on this application'
g ant ", t : ,' - ;s ay pP
®1-and 2-family dwelling 0 Commercial/industrial Valuation: $ $24,700.00
❑Accessory building 0 Multi-family Number of bedrooms: •
❑Master builder 0 Other: Number of bathrooms:
A6'Y 9 y�
��� , " ^�;z` r��rya �,,, �� � ,�� g ` � � ^; z ; "" / Total number of floors:
Job site address: 7844 SW Ashford Street New dwelling area: square feet
City/State/ZIP: Tigard OR 97224 Garage/carport area: square feet
Suite/bldg./apt.no.: Project name: Kemena Covered porch area: square feet
Cross street/directions to job site: Deck area: square feet
Other structure area: square feet
Subdivision: Lot no.: Permit fees*are based on the value of the work performed.
Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all
r equipment,materials,labor,overhead,and the profit for the
- a;j -_g ° r;r * r; i �/t, work indicated on this application.
Adding 8.05 kW Roof Top Solar PV System Valuation: $
Existing building area: square feet
New building area: square feet
h
/ g.:i.r r i1 � f 4,ii Number of stories:
Name: Nicole Kemena Type of construction:
Address: 7844 SW Ashford Street Occupancy groups:
City/State/ZIP: Tigard OR 97224
Existing:
Phone:(916)494 8794 Fax:( )
3g ,eNew e iy / ", , 's 31Pa� > � , a , j i g Ie ,
Business name: Premier Solar NW
Structural plan review fee(or deposit):
Contact name: Robert M. Rathbone
FLS plan review fee(if applicable):
Address: 12399 NW Waker Dr.
Total fees due upon application:
City/State/ZIP: Portland, OR 97229
Amount received:
Phone:( 503-$28-9500 Fax::( )
E-mail: rrathbone@premiersolarnw.com '` ' -at
} ,a / i r r " f'. y Commercial and residential prescri tive installation of
«r. P
y h/< �� p> fig' 5?' �g Swr f / / /�
; '' '.y% x;�t''Y /� k�,m ,/,, „' rooftop mounted PhotoVoltatc Sotar Panel System.
Business name: Premier Solar NW Submit two(2)sets of roof plan with connection details
and fire department access,along with the 2010 Oregon
Address: 12399 NW Waker Dr. Solar Installation Specialty Code checklist.
City/State/ZIP: Portland, OR 07229 Permit Fee(includes plan review $180.00
and administrative fees):
Phone:( 503-$28-9500 Fax:( ) State surcharge(12%of permit fee): $21.60
CCB lie.: 218826
Total tee due upon application: $201.60
Authorized signature: " This permit application expires if a permit is not obtained
J.,
within 180 days after it has been accepted as complete.
Print name: Clifford Barry Date: 7/16/21 *Fee methodology set by Tri-County Building Industry
Service Board.
I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB)
Electrical Permit Application—City of Tigard
Page 2—Supplemental Information
Limited Energy Permit Fees: Renewable Energy Permit Fees:
Description Qty. Each Total
Fee for all residential systems combined: $75.00 Renewable electrical energy systems:
5 kva or less 100.70 2
Check Type of Work Involved:
5.01 to 15 kva 133.56 In.Scp 2
n A• udio and Stereo Systems* 15.01 to 25 kva 200.34 2
Wind generation systems in excess of 25 kva:
E Burglar Alarm 25.01 to 50 kva 301.04 2
50.01 to 100 kva 552.26 2
E Garage Door Opener* >100 kva(fee in accordance 2
with OAR 918-309-0040) 552.26
n Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva:
System*
Each additional kva over 25 7.42 3
E Vacuum Systems* >100 kva—no additional charge 0.0 3
Each additional inspection over allowable in any of the above:
❑ Other: Each additional inspection is 66.25/hr 1
charged at an hourly(1 hr min)
Inspections for which no fee is 90.00/hr
s.ecificall listed(Y2 hr min
d ✓ �AH��� 'i'& '�b� ' ��.,
y1 €i �.s�. .a te- ` �c,
Fee for each commercial system: $75.00 Number of ins Subtotal(Enter on Page 1):
(SEE OAR 918-309-0000) , awns allowed per peraut.
Check Type of Work Involved:
❑ Audio and Stereo Systems
❑ Boiler Controls
n C• lock Systems
❑ Data Telecommunication Installation
❑ Fire Alarm Installation
❑ HVAC
n Instrumentation
❑ Intercom and Paging Systems
n L• andscape Irrigation Control*
❑ Medical
n Nurse Calls
❑ Outdoor Landscape Lighting*
❑ Protective Signaling
❑ O• ther:
Total number of commercial systems:
*No licenses are required. Licenses are required for all
other installations
1:1Ruilding\PermitsFELC_PennitApp_ELR_ERE.doc Rev 06117l2015
RECEIVED
City of Tigard
Building Division JUL t 90Z.
13125 SW Hall Blvd,Tigard,OR 97223 CITY OF TIGARD
Phone: 503.718.2439 Fax: 503.598.1960
BUILDING DIVISION
1 c A R D Inspection Line: 503.639.4175
www.tigard-or.gov
2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: 7844 SW Ashford Street
City: Tigard OR Zip: 97224
Owner's Name: Nicole Kemena Date: 7/16/21
Contractor's Name: Premier Solar NW CCB #: 218826
Design Parameters of the Property/Structure
If"Yes", does not
Flood Hazard Is the installation ❑ Yes qualify for the
Area Located in a flood prescriptive path, follow
plain/flood way? n No OSSC or ORSC for
design requirements.
Wind Exposure Is the wind exposure C Yes If"Yes", qualifies for
"C"or less`. n No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes", qualifies for
family townhomes Q Yes the prescriptive path.
and/or their accessory
Ground structures. ❑ No
Snow Load Is the Ground Snow
Installations on all Load 50 ps or less?
structures other than "Yesqualifies for
Yes the If prescriptive path.
above
❑ No
1
1:/Building/Forms/PhotoVoltaic-Checklist02-01-11_docx
Is the construction
material wood and does 0 Yes
Type of If"Yes", qualifies for
the construction qualify
Construction as"conventional light E No the prescriptive path.
frame"construction?
Is the spacing 24 inches
or less?
Pre-engineered trusses. Yes If"Yes", qualifies for
the prescriptive path.
n No
Roof framing
members Is the spacing 24 inches
or less?
Nominal lumber. If"Yes", qualifies for
0 Yes the prescriptive path.
❑ No
Is the combined weight ® Yes
of the PV modules and If"Yes", qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation layout in accordance X Yes
with Section 305.4(3) of If"Yes", qualifies for
❑
the 2010 Oregon Solar No the prescriptive path.
Code?
Li Metal
Single layer If roofing material is
Roofing Check the type of ❑ of wood one of the three types
material roofing material shingle/shake checked, qualifies for
Max. two layers the prescriptive path.
U of composition
shingle.
Is the roof mounted C Yes
Connections of solar assembly If"Yes", qualifies for
the solar assembly connected to roof No
to the roof framing or blocking ❑ the prescriptive path.
directly?
2
1:/Building/Forms/1'hotoVoltaic-Checklist02-01-11.docx
U Yes If"Yes", qualifies for
Is the gauge 26 or less?
(1 No the prescriptive path.
115 lbs for 60 inch
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
n No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes", qualifies for
n Yes the prescriptive path.
❑ No
Attachment of
roof mounted Minimum 24 inches If the spacing falls
solar systems Spacing of clamps? within 24 inches and 60
directly to inches Maximum 60 inches inches, qualifies for the
standing seam prescriptive path.
metal panels Width of roofing If the width of the panel
panels? 18 inches or less is less than 18 inches,
inches qualifies for the
prescriptive path.
Minimum#10 at 24
inches o/c?
Size and spacing of If"Yes", qualifies for
fastener? Yes the prescriptive path.
❑ No
Is the roof decking of
WSP min. t/"thickness, n Yes
decking connected to If"Yes", qualifies for
framing members ❑ No the prescriptive path.
w/min. 8d nails @
6"/12"o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If"Yes", qualifies for
module to the roof x❑ Yes theprescriptive ath.
solar modules p
surface. ❑ No
3
1:/Building/Forms/PhotoVoltaic-Checklist02-01-11.docx
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing(rafter size, type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer: Panasonic
Model Number: EverVolt 350
Listing Agency: UL
4
1:/Building/Forms/PhotoVoltaic-Checklist02-01-1 l.docx