Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
.rneurreruuwxaauuruuruuru+...r.. ....v - .. . CITY OF TIGARD ELECTRICAL PERMIT *. COMMUNITY DEVELOPMENT Permit#: ELC2021-00335 Date Issued: 8/2/2021 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 1 S1260000300 Jurisdiction: Tigard Site address: 9374 SW WASHINGTON SQUARE RD R05 Project: Peloton Subdivision: None Lot: None Project Description: Electrical for TI:(1)200 amp feeder,(73)branch circuits,and low voltage for audio/stereo,data telecommunications,and fire alarm systems. Contractor: ERTELL ELECTRIC LLC Owner: PPR WASHINGTON SQUARE LLC PO BOX 279 BY MACERICH RET FOREST GROVE,OR 97116 PO BOX 4085 SANTA MONICA, CA 90411 PHONE: 503-841-4511 PHONE: FAX: 503-359-5652 FEES Quantity Description Date Amount 1 ea Services or Feeders-200 07/21/2021 $100.70 Specifics: amps or less 73 crt Branch Circuits w/Purchase 07/21/2021 $541.66 Type of Use: COM Service or Feeder Class of Work: ALT 3 ea Signal circuit or Limited 07/21/2021 $225.00 Type of Const: Energy Panel Occupancy Grp: 1 ea Plan Review Electricial 07/21/2021 $216.84 1 ea 12%State Surcharge- 07/21/2021 $104.08 Electrical 16 ea Info Process/Archiving-Lg 07/21/2021 $32.00 $2.00(over 11x17) Total $1,220.28 Required Items and Reports(Conditions) This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 throuah OAR 952-001-0090. You may obtain a copy of the rules or direct auestions to OUNC by callina 503.232.1987 or 1.800.332.2344. Issued By: VavvDe,Weje Permittee Signature: OW OWNER INSTALLATION ONLY The installation is being made on property I own which is not intended for sale,lease or rent. OWNER'S SIGNATURE: Date: CONTRACTOR INSTALLATION ONLY SIGNATURE OF SUPR.ELEC'N Date: LICENSE NO. Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. 6ii ./ -6 Electrical Permit Application IOR()HILL 1 si_OyI_i. City of Tigard Received 111 -" 13125 SW Hall Blvd.,Tigard,OR 9722ECEIVEDPIanReview �f �r�� it#: ���1/' �33� Phone: 503.718.2439 Fax: 503.598.1960 DPateBy: �� /2_'5'/i. elated Permit t: �% Inspection Line: 503.639.4175 JUN Ready Date/By: tuns See Page 2 for T I G A R D Internet: vvww.tigard-or.gov 11 Notified/Method: 7/a7/ ),I ij t Supplemental information TYPE OF WORK3I• / OF IGARI.' 1: ,V.cf v /h LAN REVIEW 0 New construction 0Addition/alteratio j \' �} Please c ck all that apply(submit 2 sets of plans w/items checked): 'j� �lV�.-i I]I Y I�I'^" ❑Service or feeder 400 amps or more 0 Building over three stories. ❑Demolition ❑Other: where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or ❑Floating buildings. 1-and 2-familydwelling ■ Commercial/industrialless to ground,or exceeds 14,000 0 Commercial-use agricultural ❑ ❑ 0Accessory building amps far all other installations. buildings. ❑Multi-family 0 Master builder 0 Other: 0 Fire pump. 0 Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION n Emergency system. larger separately derived 0 Addition of new motor load of system. Job#: Job site address:9374 SW Washington Square Road 100HP or more. ❑"A "E "1-2 "1-3", ❑Six or more residential units. occupancy. City/State/ZiP:Tigard, OR 97223 ❑Health-care facilities. 0 Recreational vehicle parks. Suite/bldg./apt.#:R05 Project name:Peloton Washington Square 0 Hazardous locations. 0 Supply voltage for more than ❑Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: FEE SCHEDULE Washington Square Road Description I Qty. J Each i Total I New residential single-or multi-family dwelling unit. Includes attached garage. Subdivision:Washington Square Mall Lot#: g• g Tax map/parcel#:1 S1260000300 1,000 sq.ft or less 168.54 4 Ea.add'I 500 sq.ft.or portion 33.92 1 DESCRIPTION OF WORK Limited energy,residential 75.00 2 (with above sq.ft.) TENANT IMPROVEMENT:NEW INTERIOR LIGHTING,POWER AND DATA FOR AV/IT,AND Limited energy,multi-family — FLOOR OUTLETS FOR PRODUCTS.LIGHTING FIXTURE COUNT 352 residential(with above sq.ft.) 75.00 2 Renewable Energy 0 See Page 2 ❑ PROPERTY OWNER ® TENANT Services or feeders installation,alteration,and/or relocation Name:One Peloton 200 amps or less Ie:'ru_>nsoI! X 100.70 ill).), 2 Address:125 W 25th Street, 11th Floor 201 amps 10 aoo amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZiP:New York, NY 10001 601 amps to i,000 amps 301.04 2 Phone:( ) Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: relocation ' Owner installation:This installation is being made on property that 1 own which is not 200 amps or less 59.36 I '' intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 11APPLICANTBranch circuits—new,alteration,or extension,per panel 0 000NTACT PERSON A.Fee for branch circuits with Business name:Paroline&Associates above service or feeder fee,eac 7 42 51 (� 2 Feet-,k h bor nch circuit J Contact name:April House B. for branch circuits without service or feeder fee,first Address:3617 SW Charlestown St branch circuit 56.18 2 R' City/State/ZIP:Seattle WA 98126 Each add'l branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:( )206-478-0844 Fax: :( ) Each manufactured or modular dwelling,service and/or feeder 67.84 2 Email:permits@parolineassociates.com Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name:TBD Sign or outline lighting 67.84 2 Signal circuit(s)or limited-energy Address: panel,alteration,or extension. 'See Page 2 j.S 2 City/State/ZIP: Each additional inspection over allowable in any of the above Additional inspection(I hr min) 66.25/hr Phone:( ) Fax:( ) Investigation(1 hr min) 90.00/hr industrial plant(I hr min) 78.18/hr Email: inspections for which no fee is 90.00/hr CCB Lie.: Electrical Lie.: Suprv.Lie.: specifically listed(/a hr min) ELECTRICAL PERMIT FEES Suprv.Electrician signature,required: Subtotal 1-6, 7, 3to Print name: Date: 0 Plan Review Required(25%of permit fee): 24 6.`61 State surcharge(12%of permit feeE). j U k e, Authorized signature: TOTAL PERMIT FE 915 This permit application expires if a permit is not obtained within ISO Print name:April House c,;,...,ed Date:06/10/2021 days after it has been accepted as complete. * Number of inspections allowed per permit. I:\Building\Permits\ELC_PermitApp_ELR_EREdoc Rev O6/1712015 440-4615T(11/05/COM/WEB L /t ) Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY: FEE SCHEDULE Description ( Qty. I Each j Total Fee for all residential systems combined: $75.00 Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 ❑ Garage Door Opener* 50.01 to 100 kva 552.26 2 >100 kva(fee in accordance 552.26 2 with OAR 918-309-0040) ❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva-no additional charge 0.0 3 Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspection is 66.25/hr 1 charged at an hourly(1 hr min) Inspections for which no fee is 90.00/hr specifically listed(Y2 hr min) COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES Subtotal(Enter on Page 1): Fee for each commercial system: $75.00 * Number of inspections allowed per permit. (SEE OAR 918-309-0000) Check Type of Work Involved: ® Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems • Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: 3 *No licenses are required. Licenses are required for all other installations I:\Building\Permits\ELC PermitApp ELR_ERE,doc Rev 06/17/2015 Electrical Permit Application FOR OFFICE LSE ONLY City of Tigard Received II 13125 SW Hall Blvd.,Tigard.OR 97223 Plan Review Phone: 503.718.2439 Fax: 503.598.1960 Date B Permit tt:Related Permit P: Inspection Line: 503.639.4175 Ready Date/By lures, ® Sec Page 2 for TIGARD, Internet: www.tigard-or.gov Notificd'Mcthod: Supph mental Information TYPE OF WORK PLAN REVIEW ❑New construction 0 Addition alteration'replacement Please check all that apply(submit 2 sets of plans w tcms checked): ❑Service or fecdcr 400 amps or more 0 Buildin;over three stories. ❑Demolition ['Other: where the available fault current 0 Marina and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floatin; buildings. ❑ 1-and 2-family dwelling 0 Commercial industrial ❑Accessory building less to ground,or exceeds 14,000 ❑Commercial-use agricultural amps for all other installations. buildings. ❑ Multi-family ❑Master builder ❑Other: 0 Fire pump. 0 Installa ion of 150 KVA or JOB SITE INFORMATION AND LOCATION ®Emergency system. larger s iparatcly derived ❑Addition of new motor load of system. Job#: Job site address:9374 SW Washington Square Road 10011P or more. ❑`A "r 1-2"• 1-3"• ❑Six or more residential units. occupai:cy. City State/ZIP:Tigard, OR 97223 0 Health-care facilities. 0 Recreat.onal vehicle parks. Suite/bld /a t.#:R05 Project name:Peloton Washington Square 0 Hazardous locations. ❑Supply voltage for more than $- p J g q 600 vol s nominal. ❑Service or feeder 600 amps or more. Cross street/directions to job site: FEE SCHEDULE Description I Qty. I Each I Total I Washington Square Road New residential single-or multi-family dwe ling unit. Subdivision:Washington Square Mall Lot#: Includes attached garage. 1.000 sq.ft.or less 163.54 4 Tax map/parcel#:1 S1260000300 Ea.add'l 500 sq.ft or portion 31.92 1 DESCRIPTION OF WORK Limited energy,residential 75.00 2 (with above sq.ft.) TENANT IMPROVEMENT:NEW INTERIOR LIGHTING;POWER AND DATA FOR AV/IT,AND — Limited energy,multi-family , FLOOR OUTLETS FOR PRODUCTS.LIGHTING FIXTURE COUNT 352 residential(with above sq.ti.) 7 i.00 Renewable Energy 0 See Page 2 ❑ PROPERTY OWNER © TENANT Services or feeders installation,alteration,a nd/or relocation Name:One Peloton 200 amps or less extension X 10).70 2 201 amps to 400 amps 131.56 2 Address:125 W 25th Street, 11th Floor 401 amps to 600 amps 20).34 City State/ZIP:New York, NY 10001 601 amps to 1,000 amps 301.04 2 Phone:( ) Fax: ( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation, alteration,and/or Email: relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 51.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 123.08 2 Owner signature: Date: 401 amps to 599 amps 163.54 2 Branch circuits—new,alteration,or extension,per panel 0 APPLICANT 0 CONTACT PERSON A.Fee for branch circuits with �-.-7 Business name:Paroline & Associates above service or feeder fee. 1"I 7.42 2 each branch circuit Contact name:April House B.Fcc for branch circuits without service or feeder fcc.first 55.18 ' Address:3617 SW Charlestown St branch circuit CityEach add'I branch circuit 7.42 2 Stale'ZIP:Seattle WA 98126 Miscellaneous(service or feeder not included) Phone:( )206-478-0844 Fax: :( ) Each manufactured or modular 6 7.84 2 dwelling,service and'or feeder Email:permits@parolineassociates.com Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name:Ertell Electric, LLC Sign or outline lighting 67.84 2 Signal circuits)or limited-energyEl See Pa to 2 Address:5293 NE Elam Young Parkway Suite 120 panel,alteration,or extension. Each additional inspection over allowable in any of the above City Statel7_IP:Hillsboro,OR 97124 Additional inspection(I hr min) 66.25/hr Phone:( )503-596-2199 Fax:( ) Investigation(I hr min) 90.)0/hr Industrial plan:(I hr min) 78.18/hr Email:billing@ertellselectrie.com Inspections fot which no fee is specifically listed('/hr min) 90.)0/hr CCB Lic.:180540 Electrical Lic.:C390 Suprv.Lic.:5420S ELECTRICAL PERMIT F'sES Suprv.Electrician signature,required: t ��� _ Subtota: Print name:Dylan Wentworth Date:07/26/2021 0 Plan Review Required(25°o of permit fee State surcharge(12%of permit fee,: TOTAL PERMIT FEI: Authorized signature: This permit application expires if a permit is not obtained within 180 Print name:April House Date:06/10/2021 days after it has been accepted as c.mplete. p ' Number of inspections allowed per permit. I.Hu,idmg Permits ELCPermitApp_EL R_E.RE.doc Rev 06.'17:2015 440-4615TI I l/05'COM/WEB Electrical Permit Application —City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY: FEE SCHEDULE Description I Qls• I Each I Total I • Fee for all residential systems combined: $75.00 Renewable electrical energy systems: 5 kva or less 101.70 2 Check Type of Work Involved: 5.01 to 15 kva 131.56 2 E Audio and Stereo Systems* 15.01 to 25 kva 201.34 2 Wind generation systems in excess of 25 kv:.: I Burglar Alarm 25.01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 I I Garage Door Opener* >100 kva(fee in accordance 2 with OAR 918-309-0040) 55)__6 n Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 n Vacuum Systems* >100 kva-no additional charge 0.0 3 Each additional inspection over allowable in any of the above: n Other: Each additional inspection is 66.2;/hr charged at an hourly(1 hr min) Inspections for which no fee is 90.0 11 In- specifically listed(Y-_lu min) ELECTRICAL. PERMIT K ES COMMERCIAL WORK ONLY: Subtotal(Enter on Page I): Fee for each commercial system: $75.00 • Number of inspections allowed per permit. (SEE OAR 918-309-0000) Check Type of Work Involved: RI Audio and Stereo Systems I I Boiler Controls n Clock Systems [A Data Telecommunication Installation (v Fire Alarm Installation I HVAC n Instrumentation Intercom and Paging Systems I I Landscape Irrigation Control* Medical C Nurse Calls Outdoor Landscape Lighting* n P• rotective Signaling n O• ther: Total number of commercial systems: 3 *\o licenses are required. Licenses are required for all other installations I:Building Permits FLC_PermitApp_ELR ERE.dtx Rev 06.17/2015 COMcheck Software Version COMcheckWeb rill 1 Interior Lighting Compliance Certificate RECEIVED Project Information JUN 1 1 Z0Z1 Energy Code: 90.1 (2019) Standard CITY OF TIGARD Project Title: Peloton at Washington Square BUILDING DIVISION Project Type: Addition Construction Site: Owner/Agent: Designer/Contractor: 9355 SW Washington Square road One Peloton Thorson Baker and Associates Portland, Oregon 97223 441 Ninth Avenue, Sixth Floor 3030 W Streetsboro Road New York, New York 10001 Richfield, Ohio 44286 979-229-0987 Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed (ft2) Watts/ft2 Watts 1-Main Sales(Retail:Sales Area) 1463 1.05 1536 Allowance: Other retail highlighting/Fix. ID:Cl 1097(a) 0.45 494(b) 2-Secondary Sales(Retail:Sales Area) 495 1.05 520 3-Trial Room 1 (Common Space Types:Office- Enclosed <=250 sq ft) 82 0.74 61 4-Trial Room 2 (Common Space Types:Office- Enclosed <=250 sq ft) 82 0.74 61 5-Trial Room 3 (Common Space Types:Office- Enclosed <=250 sq ft) 103 0.74 76 6-Trial Room 4 (Common Space Types:Office- Enclosed <=250 sq ft) 103 0.74 76 7-Storage closet(Common Space Types:Storage >=50- <=1000 sq.ft.) 55 0.43 24 8-Restroom (Common Space Types:Restrooms) 100 0.63 63 9-BOH (Common Space Types:Storage >=50- <=1000 sq.ft.) 426 0.43 183 10-Fitting Room (Retail:Dressing/Fitting Room) 47 0.51 24 Supplemental Allowed Watts(null) = 94 Total Allowed Watts = 3211 (a)Area claimed must not exceed the illuminated area permitted for this allowance type. (b)Allowance is (B x C)or the actual wattage of the fixtures given in Section 2, whichever is less. (c)Supplemental watts must be associated with retail merchandise highlighting fixtures. Supplemental watts are not included calculation of lighting complaince percentage. Proposed Interior Lighting Power A B C D E Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixture Watt. 1-Main Sales (Retail:Sales Area) LED: D2: LED Downlight: Other: 1 22 18 396 LED: Cl: Linear Cove: Other: 1 147 4 588 LED: P3: Pendant Fixture: Other: 1 4 17 68 2-Secondary Sales (Retail:Sales Area) LED: D2: LED Downlight: Other: 1 11 18 198 LED: Cl: Linear Cove: Other: 1 32 4 128 LED: P3: Pendant Fixture: Other: 1 1 51 51 3-Trial Room 1 (Common Space Types:Office - Enclosed <=250 sq ft) LED: L7: Linear LED: Other: 1 24 4 96 Project Title: Peloton at Washington Square Report date: 06/07/21 Data filename: Page 1 of 6 A B C D E Fixture ID : Description / Lamp /Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixture Watt. 4-Trial Room 2 (Common Space Types:Office - Enclosed <=250 sq ft) LED: L7: Linear LED: Other: 1 24 4 96 5-Trial Room 3 (Common Space Types:Office - Enclosed <=250 sq ft) LED: L7: Linear LED: Other: 1 30 4 120 6-Trial Room 4 (Common Space Types:Office - Enclosed <=250 sq ft) LED: L7: Linear LED: Other: 1 30 4 120 7-Storage closet (Common Space Types:Storage >=50 - <=1000 sq.ft.) LED: D2: LED Downlight: Other: 1 4 18 72 8-Restroom (Common Space Types:Restrooms) LED: D3: LED Downlight: Other: 1 4 14 56 LED: P4: Mirror Pendant: Other: 1 1 10 10 9-BOH (Common Space Types:Storage >=50 - <=1000 sq.ft.) LED: L5: LED Flat Panel: Other: 1 15 38 570 10-Fitting Room (Retail:Dressing/Fitting Room) LED: D2: LED Downlight: Other: 1 2 18 36 Total Proposed Watts = 2605 nterior Lighting PASSES: Design 16%better than code Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 90.1 (2019) Standard requirements in COMcheck V sion COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Jeff D. Miterko, P.E. 6/9/2021 Name-Title Signature Date Project Title: Peloton at Washington Square Report date: 06/07/21 Data filename: Page 2 of 6 44, COMcheck Software Version COMcheckWeb 1 r i Inspection Checklist Energy Code: 90.ift 1 (2019) Standard Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Req.ID 4.2.2, Plans, specifications, and/or ❑Complies Requirement will be met. 8.4.1.1, calculations provide all information ❑Does Not 8.4.1.2, with which compliance can be 8.7 determined for the electrical systems ENot Observable [PR6)2 and equipment and document where ❑Not Applicable exceptions are claimed. Feeder connectors sized in accordance with approved plans and branch circuits sized for maximum drop of 3%. 4.2.2, Plans, specifications, and/or ❑Complies Requirement will be met. 9.4.3, 9.7 calculations provide all information ❑Does Not [PR4]' with which compliance can be determined for the interior lighting ['Not Observable and electrical systems and equipment ❑Not Applicable and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts,transformers and control devices. Additional Comments/Assumptions: 1l Impact(- L 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) ! 3 Low (Tier 3) 1, Project Title: Peloton at Washington Square Report date: 06/07/21 Data filename: Page 3 of 6 Section # Rough-In Electrical Inspection Complies? Comments/Assumptions & Re IDS 8.4.2 At least 50%of all 125 volt 15-and ❑Complies Exception: Space type is not private office, open office, or 1[EL10]2 20-Amp receptacles are controlled by ❑Does Not computer classroom. an automatic control device. ❑Not Observable :Not Applicable 8.4.3 New buildings have electrical energy ❑Complies Requirement will be met. [EL11]2 use measurement devices installed. ❑Does Not Where tenant spaces exist, each tenant is monitored separately. In ❑Not Observable buildings with a digital control system ❑Not Applicable the energy use is transmitted to to control system and displayed graphically. 9.4.1.1 Automatic control requirements ❑Complies Requirement will be met. [ELi]2 prescribed in Table 9.6.1,for the ❑Does Not appropriate space type, are installed. ['Not Observable Mandatory lighting controls(labeled as 'REQ') and optional choice controls ❑Not Applicable (labeled as'ADD1' and 'ADD2')are implemented. 9.4,1.1a Independent lighting controls installed ❑Complies Requirement will be met. [EL2]2 per approved lighting plans and all ❑Does Not manual controls readily accessible and ❑Not Observable visible to occupants. ❑Not Applicable 9.4.1.1b No lighting shall be automatically ❑Complies Exception: Manual on function would endanger safety and [EL26]2 turned on-restriced to manual. ❑Does Not security. ❑Not Observable ❑Not Applicable 9.4.1.1c <= 50%of general lighting power ❑Complies Requirement will be met. [EL27]2 shall be allowed to be automatically ❑Does Not turned on. ❑Not Observable ❑Not Applicable 9,4.1.1d Bilevel lighting control - <= 50%of ❑Complies Requirement will be met. [EL28]2 general lighting controlled with one ❑Does Not intermediate step between full off and full on. ❑Not Observable ❑Not Applicable 9.4.1.1e Automatic daylight responsive ❑Complies Exception: Retail lighting. [EL29]2 controls for sidelighting >= 150 watts ❑Does Not controlled by photocontrols. ['Not Observable ❑Not Applicable 9.4.1.1f Automatic daylight responsive ❑Complies Exception: Requirement does not apply. ([EL30]2 controls for toplighting >= 150 watts ❑Does Not controlled by photocontrols. ❑Not Observable ❑Not Applicable 9.4.1.1g Automatic partial OFF: lighting shall ❑Complies Requirement will be met. =[EL31]2 be reduced >= 50%within 20 minutes ❑Does Not of zero occupancy. ❑Not Observable ❑Not Applicable 9.4.1.1h Automatic full OFF: lighting shall be ❑Complies Exception: General lighting and task lighting in spaces where [EL32]2 shut off within 20 minutes of zero ❑Does Not automatic shutoff would endanger the safety or security of occupancy. ❑Not Observable room or building occupants. ❑Not Applicable 9.4.1.1i Scheduled shutoff: all lighting shall be ❑Complies Requirement will be met. [EL33]2 shut off when scheduled to be ❑Does Not unoccupied. ['Not Observable ❑Not Applicable 1 'High Impact(Tier 1) 12_Medium Impact(Tier 2) 1 3 Low Impact(Tier 3) Project Title: Peloton at Washington Square Report date: 06/07/21 Data filename: Page 4 of 6 • , Section # Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID 9.4.1.3 Separate lighting control devices for ❑Complies Requirement will be met. [EL4]1 specific uses installed per approved ❑Does Not lighting plans. ['Not Observable ❑Not Applicable 9.6.2 Additional interior lighting power ❑Complies Requirement will be met. [EL8]1 allowed for special functions per the ❑Does Not approved lighting plans and is ❑Not Observable automatically controlled and separated from general lighting. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) f 2 Medium Impact(Tier 2) 13 Low Impact(Tier 3) Project Title: Peloton at Washington Square Report date: 06/07/21 Data filename: Page 5 of 6 Section # Final Inspection Complies? Comments/Assumptions 1& Req.ID 8.7.1 Furnished as-built drawings for ❑Complies Requirement will be met. [FI16]3 electric power systems within 30 days ❑Does Not of system acceptance. ❑Not Observable ❑Not Applicable 8.7.2 Furnished O&M instructions for ❑Complies Requirement will be met. [FI17]3 systems and equipment to the ❑Does Not building owner or designated ❑Not Observable representative. ❑Not Applicable 9.2.2.3 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values. [F118]i lighting power is consistent with what ❑Does Not is shown on the approved lighting ❑Not Observable plans, demonstrating proposed watts are less than or equal to allowed ❑Not Applicable watts. ---------------- 9.4.4 At least 75%of all permanently ❑Complies Requirement will be met. [F120]1 installed lighting fixtures in dwelling ❑Does Not units have >= 55 Im/W efficacy or a >= 45 Im/W total luminaire efficacy. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2.'Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Peloton at Washington Square Report date: 06/07/21 Data filename: Page 6 of 6 Branden Taggart From: #Building Permit Technicians Sent: Wednesday,July 21, 2021 2:38 PM To: 'April House' Cc: Holly Van De Wege Subject: RE: ELC2021-00335 - 9374 SW Washington Square Rd. Attachments: Invoice.pdf;Application Copy.pdf Hi April, The Electrical permit for Peloton at Washington Square Mall is ready to issue now. The balance due is$1,220.28, and I have attached an invoice above for you to reference. These fees can be paid online now at https://aca- prod.accela.com/TIGARD/Welcome.aspx by searching for the permit record number ELC2021-00335 under the Building tab. There is a 3%service fee for credit cards, but e-checks do not have a service fee. Once paid, please email the Permit Technicians at TigardBuildingPermits@tigard-or.gov so that we may issue this permit and make it available for pick up. Please note that contractor license information and a Supervising Electrician's signature are required prior to permit issuance. I have attached a copy of the application above for the contractor to sign. Thank you, Branden Taggart III ■ City of Tigard Senior Permit Technician Community Development Ct;.AI+I) 13125 SW Hall Blvd Tigard,OR 97223 (503)718-2449 brandent@tigard-or.gov From:April House<april@parolineassociates.com> Sent:Tuesday,July 20, 2021 12:27 PM To:#Building Permit Technicians<TigardBuildingPermits@tigard-or.gov> Subject: [CAUTION: SUSPECT SENDER] BUP2021-00135 & ELC2021-00335 Warning!This message was sent from outside your organization and we are unable to verify the sender. Hi Team, Checking on the following permits issuance timeline. Can you provide? BUP2021-00135&ELC2021-00335 Thanks APRIL HOUSE I PROJECT MANAGER PAROLINE&ASSOCIATES I PERMIT CONSULTING 3617 SW CHARLESTOWN ST I SEATTLE WA 98126 206.478.0844 I WWW.PAROLINEASSOCIATES.COM 1 1