Report 1:Rsr2o2.1--cotes OFFICE Copy I11 P RTER„ s INC . 7320 NE St. Johns Road •Vancouver,WA 98665 • 360-574-1366 • Lic# PORTEE1554DK • Fax 360-573-3723 Fire Alarm Product Submittals: Project: Dartmouth Apartments RECEIVED 11882 SW 72nd Ave 11974 SW 72nd Ave MAY 1 0 2021 Tigard, OR 97223 CITY OF TIGARD BUILDING DIVISION System: Fire Alarm System for Sprinkled Mixed Use Building Submittal Index: Page 1: Cover Page Page 2: FACP (Fire Alarm Control Panel) Specifications Model 6820 Page 6: RACP(Remote Annunciator Panel) Specifications PN#5860R Page 8: BEP (AV Power Expansion) Specifications Model 5496 Page 10: Cellular Alarm Communicator Panel Specifications PN#TG7LVF01 Page 12: Manual Pull Station Specifications PN#SK-PULL-SA Page 14: Photo Electric Smoke Detector Specifications PN#SK-Photo Page 16: Heat Detector Specifications PN#SK-Heat Page 18: Supervising Module Specifications PN#SK-Monitor-2 Page 20: Control Module Specifications PN#SK-Relay Page 22: Unit Low Frequency Horn Specifications PN#GHLFW Page 24: Common Area Horn& Horn-Strobe Specifications PN#s GCC24CW&GCS24CW Page 28: Common Area Wall Horn & Horn-Strobe Specifications PN#WGEC24-75WR Page 32: Bell Specifications PN# MBA2410 Page 34: Battery Specifications PN#s NP7-12 & NP18-12B Submitted by: Bill Robinson BR@PORTERElectriclnc.com 7320 NE St John's Rd Vancouver WA 98665 OFFICE COPY Office: 360-574-1366 Fax: 360-573-3723 Honeywell ( Addressable Fire Alarm Control Panels ElSILENT'T KMGH 6820 Ill IIIIIIIIIII Addressable Fire Alarm Control Panel The 6820 is an addressable fire alarm control panel(FACP)and is a direct replacement for the 5820XL FACP.The 6820 can be configured to achieve a point capacity of 1110 points and connect up to 17 panels in a single communications link. The 6820 has one built-in signaling line circuit(SLC),which can support 159(SK)System Sensor'sensors and 159 SK modules or 127 (SD)Hochiki®devices per loop.To increase point capabilities,additional SLC loops can be added using the 6815 SLC expander for SK devices or the 5815XL expander for SD devices,increasing the point capacity to a 6820 maximum of 1110 points for SK devices and 635 points for SD devices. Three additional SLCs are needed to reach 1110 points(SK devices). The 6820 also has a form-C trouble relay,two Four additional SLCs are needed to reach 635 points(SD devices). programmable form-C relays,along with powerful A common communications and annunciation link allows up to 17 features such as drift compensation,pre trouble panels to be connected via copper or fiber optic cable.A designated maintenance alert,a built-in sensor test to panel is configured as the communicator for all panels in the link for comply with NFPA 72 calibration testing convenient single-point communications.It also has a built-in,dual- requirements,and calibration trouble alert. line POTS and IP communicator with additional cellular options The 6820 su available pports a variety of devices,including the 6860,5860,and 6855 remote annunciators, The 6820 system can be enhanced by adding modules such as the 5824 serial parallel printer interface module(for 6860 remote annunciator which also has four programmable function printing system reports),the 5496 NAC expander, buttons to help automate tasks and reduce time spent at the panel. 5895XL power module,and SK or SD devices. SWIFT"wireless compatibility provides options for wireless detection through a Class A mesh network.It is ideal for hard-to-wire locations, buildings where new wiring is not allowed,or to provide an easy install fire system for new construction projects SWIFT devices can be combined with other hard-wired 6820 compatible devices. FEATURES & BENEFITS • Capable of providing • Connect up to 17 • Built-in dual path • Programmable date • Flexput" circuits can up to 1110 points for panels on one site with POTS and IP setting for automatic be individually enhanced design convenient single- communications with and convenient programmed to flexibility.Additional point access using the optional cellular Daylight Saving Time function as Signal Line Circuits SK-NIC Network models available for changes notification circuits, can be added until Interface Card. reliable backup • Four user- auxiliary power maximum point levels Connected panels can reporting outputs,or initiating programmable are reached have mixed compatible . 6860 annunciator with buttons minimize circuits that support • Built-in USB interface FACP models a 4 x 40 large display time spent executing both 2 and 4-wire for convenient and • Convenient complex or routine smoke detectors •quick programming field-upgradeable �umpStart"'auto tasks firmware programming reduces installation time SIGNAL LINE CIRCUIT(SLC) system silenced and system power. waterflow,sprinkler supervisory(DACT The 6815 signal line circuit(SLC) System operations include silencing non-coded)signaling services. supports multiple device types of SK alarms and troubles,resetting alarms • UL Listed:S2766 protocol,while the 5815XL signal line and the display of alarm troubles and • CSFM:7165-0559:0500 circuit(SLC)supports multiple device memory.The system's non-volatile types of SD protocol.You cannot mix SD event history buffer stores 1,000 FDNY:COA#6249 and SK SLC devices on a FACP. events for viewing from the built- • FM approved The 6820 has one built-in signaling in or remote annunciator.System ORDERING INFORMATION line circuit(SLC)which supports multiple operations can be initiated with a 6820:Addressable Fire Alarm devices.Additional points mechanical firefighter's key or a valid Control Panel.(Red cabinet). can be added using the 6815 SLC 4-to 7-digit operator's code. expanders to increase overall capacity to COMPATIBLE ANNUNCIATORS PROGRAMMING 1,110 maximum points(SK devices)or by 6860:4x40 LCD remote fire annunciator The 6820 system offers several options adding up to four 5815XL SLC expanders (4 lines and up to 160 characters)per to simplify and speed-up programming. to reach 635 maximum points(SD system;four programmable buttons JumpStart®AutoProgramming devices).The number of SLCs which can 5860:4x20 LCD remote fire is limited byminimizes programming required to be used within systemone annunciator.5860 is gray;5860R is red start a new system.The built-in keypad, point count.(See the Manual for or the 6860,5860 or 6855 remote 6855:4x20 LCD remote fire annunciator additional information.) 5865-3 or 5865-4:LED annunciators annunciators give you on-site access to The 6820 SLC loops support multiple current system programming. can display up to 30 LEDs(15 red and device types,maintenance alerts,and a Programming can also be accomplished 15 yellow).The 5865-4 has key switches built-in sensor test to comply with NFPA using the Windows"-based Honeywell for silence and reset,and a system 72 calibration testing requirements. Fire Software Suite(HFSS)program. trouble LED. 5880:The 5880 LED/10 module tr INDICATOR LIGHTS SOFTWARE TOOLS Iiiiiii has 40 programmable LED outputs and • General Alarm(Red):Flashes if in SKST:Silent Knight Selection Tool eight supervised dry contact inputs alarm;solid when alarm is silenced provides the installer or design architect which are useful for custom applications. • Supervisory(Yellow):Flashes if a with a Windows"'software system You can use up to eight 5880 modules supervisory condition exists;solid configuration tool to create a detailed on one control panel for maximum when supervisory is silenced Bill of Material(BOM)and battery flexibility.Its compact size allows • System Troubles(Yellow):Flashes calculations. mounting inside the annunciator,or in if a trouble condition exists; HFSS:Honeywell Fire Software Suite an accessory cabinet. solid when trouble is silenced provides communication and panel 6820 COMPATIBLE DEVICES AND programming,detector status,event ACCESSORIES • System Silenced(Yellow): See the data sheets listed below for a history and additional data. Requires a On when an alarm,trouble or complete listing of the SK,SD or SWIFT PC running Microsoft' Windows". devices. supervisory condition has been 53623:SK Devices Data Sheet silenced but not yet cleared ADDITIONAL INFORMATION 53624:SD Devices Data Sheet • System Power(Green):Flashes Twisted-unshielded pair wire is 350614,350616&350618:SWIFT wireless devices for AC failure;solid when recommended.The 6820 also has 13 For a complete and current listing of power systems are normal preset notification cadence patterns compatible devices and accessories,visit USER INTERFACE www.silentknight.com (including ANSI 3.41). Important:You cannot mix SK and SD The 6820 built-in 4 x 20 annunciator AGENCY LISTINGS AND APPROVALS devices in the same fire alarm system. with 80 character LCD display NFPA 13,NFPA 15,NFPA 16,NFPA 70, and large easy-to-use tactile NFPA 72:Central station;remote touchpad can be used for system Signaling;Local Protective Signaling operation,programming and Systems;Auxiliary Protected Premises maintenance.It has five LEDs for Unit;Water Deluge releasing service. alarm,supervisory,system trouble, Suitable for automatic,manual, Page 2 of 4—351610:B 9/26/2018 , SK COMPATIBLE ADDRESSABLE B200S-LF:Low-frequency intelligent WSK-PHOTO-T:Wireless Multi-criteria DEVICES sounder base photoelectric smoke detector with thermal SK-ACCLIMATE:Multi criteria detection(135°F fixed temperature)`' B224RB(-IV,-WH):Relay base and %Nophotoelectric smoke detector with thermal B224RB: Relay base B510W 4"base 135°F fixed temperature WSK-HEAT:Wireless Heat,(135°F fixed B22461(-IV,-WH):Isolator base SK-BEAM:Reflected beam smoke detector B224B1: Isolator base temperature)and B510W 4"base without test feature WSK-HEAT-ROR:Wireless heat,ROR SK-BEAM-T:Reflected beam smoke SD COMPATIBLE ADDRESSABLE (135°F fixed temperature)and B510W 4" detector with test feature DEVICES base SK-CONTROL:Supervised control module SD505-6AB:Addressable 6"base WSK-MONITOR:Wireless monitor module SK-CONTROL-6:Six circuit supervised SD505-6IB:Addressable 6"short circuit WSK-RELAY:Wireless relay module control module isolator base W-USB:SWIFT Tools USB transceiver used SK-DUCT:Photoelectric duct smoke SD505-6RB:Addressable 6"relay base for communication with SWIFT devices detector with extended air speed range SD505-6SB:Addressable 6"sounder base SK-FIRE-CO:Four criteria fire and carbon SD500-AIM:Addressable input module SBUS ACCESSORIES monoxide detector (switch input) 6815:Each Single Line Circuit allows for SK-HEAT:Fixed thermal detector(135°F) SD500-ANM:Addressable notification an additional 159 SK modules and 159 SK SK-HEAT-W:Fixed thermal detector module sensors to be added to the system-up to (135°F),white SD500-ARM: Addressable relay module 1,110 total points.Supports System Sensor SK-HEAT-ROR:Fixed rate of rise detector SD505-DTS-K: Remote test switch and SK devices only. (135°F) LED indicator for the SD505-DUCTR 5815XL:Each Single Line Circuit provides SK-HEAT-ROR-W:Fixed rate of rise detector SD505-DUCT:Addressable Duct Smoke an additional 127 SD devices to be added to (135°F),white Detector. the system-for a maximum of 635 points. SK-HEAT-HT:Fixed high temperature SD505-DUCTR:Addressable Duct Supports SD devices only. . thermal detector(190°F) Detector housing with relay base. 5496:A 6 amp notification power expander SK-HEAT-HT-W:Fixed high temperature SD505-HEAT:Absolute temperature heat with four power-limited notification thermal detector(190°F),white appliance circuit outputs. SK ISO:Fault isolator module detector.Trip point range from 135°F-150 F(0°C-37 C). 5883:Relay Interface.Provides 10 Form C SK-MINIMON:Mini monitor module SD500-LIM:Addressable Line isolator relays. SK-MONITOR:Monitor module module 5824:Serial/Parallel Printer Interface SK-MONITOR-2:Dual input monitor SD500-MIM:Addressable Mini input Module for printer connection. module monitor module(switch input) 5895XL:Power Supply with six Flexput'' SK-MON-10:10 input monitor module SD505-PHOTO:Photoelectric smoke circuits,and two Form C relays.Max.16 per '' SK-PHOTO:Photoelectric smoke detector detector system. SD500-PS/-PSDA:Addressable Single 5815RMK:Remote mounting kit. or SK-PHOTO-W:Photoelectric smoke g Dimensions 10 3/8"W x 10-3/16"H x 3"D detector,white dual action pull station SK-PHOTO-T:Photoelectric smoke detector SD500-SDM:Addressable smoke detector COMMUNICATION OPTIONS with thermal(135°F fixed temperature) module CELL-CAB-SK:Cellular communicator, SK-PHOTO-T-W:Photoelectric smoke AUDIBLE/VISIBLE DEVICES metal enclosure with lock/key* detector with thermal(135°F fixed CELL-MOD:Cellular communicator,plastic temperature),white These AV devices are all2-wire.Color:"R" indicates red:"W"denotes white.For a enclosure* SK-PHOTOR:Photoelectric detector with *Sole path,powered by panel. remote test capability complete listing of Silent Knight AV devices SK-PHOTO-R-W:Photoelectric detector go to www.silentknight.com. IPGSM-4G:Dual path fire alarm capability, communicator,cellular and/or IP(primary with remote test ca p ty,white CHSRL/CHSWL:Wall chime/strobe or backup,selectable) SK-PULL-SA:Addressable single action pull CHSCRL/CHSCWL:Ceiling chime/strobe SK-IP-2:Remote reporting via the Internet. station CHRL/CHWL:Wall chime Requires a VisorAlarm'receiver at the SK-PULL-DA:Addressable dual action pull HRL/HWL:Wall horn central station station P2RL/P2WL:Wall horn/strobe SK-RELAY:Addressable relay module PC2RL/PC2WL:Ceiling horn/strobe MISC.ACCESSORIES SK-RELAY-6:Addressable Six relay control SRL/SWL:Wall strobe SK-NIC:Network Interface Card.Provides a module SK-RELAYMON-2:Addressable Dual relay/ SCRL/SCWL:Ceiling strobe common communications link for the 6820. monitor module SPSCRL/SPSCWL:Ceiling speaker/strobe SK-NIC-KIT:Installation Accessory Kit SK-ZONE:Addressable zone interface SPSRL/SPSWL:Wall speaker/strobe SK-FML:Fiber-Optic Multi Mode, module SPRL/SPWL:Wall speaker transmitter and receiver SK-ZONE-6:Six zone interface module SPCRL/SPCWL:Ceiling speaker SK-FSL:Fiber-Optic Single Mode B300-6(-IV):6"base for SK-W Series RBB:Remote battery box accessory cabinet SWIFT WIRELESS DEVICES for batteries that are too large to fit in the B210LP:6"mounting base FACP cabinet.Dimensions:16"W x 10"H x B501(-WHITE,-IV,-BL):4"Flangeless base SWIFT is only compatible with g System Sensor(SK)devices.It is not 6"D(406mm W x 254mm H x 152mm D). B501:4"Flangeless mounting base SK-SCK:Seismic Compliance Kit used to iiiieB200S(-IV,-WH):Intelligent sounder base compatible with Hochiki(SD)devices. securely fasten batteries to the fire panel. B200S:Intelligent sounder base WSK-WGI:Wireless Gateway B200S-LF(-IV,-WH):Low-frequency WSK-PHOTO:Wireless Photoelectric smoke intelligent sounder base. detector ' Page 3 of 4—351610:B 9/26/2018 6820 Technical Specifications PHYSICAL FLEXPUT CIRCUITS Flexput`,Honeywell', Overall Dimensions:16.36"W x 26.37"H x 3.91"D Six programmable circuits which can be JumpStart Silent Knight', Shipping Weight:32 lbs SWIFT',and System pp g g programmed individually as: Sensor are registered Color:Red Notification Appliance Circuits:3A @ 27.4VDC trademarks of Honeywell per circuit,power-limited(with a panel maximum International Inc. ENVIRONMENTAL current of 6A) Operating Temperature:32°F to 120°F (0°C to Auxiliary power circuits:3A @ 27.4VDC per circuit, Hochiki"'is a registered 49°C) power-limited trademark of Hochiki Corporation.Microsoft' Humidity:0 to 93%relative humidity(non- Initiating Circuits(Circuits 5 and 6 Only):100mA and Windows'are condensing) @ 27.4VDC per circuit,power limited registered trademarks of Microsoft Corporation. ELECTRICAL Supports Class B(Style 4)and Class A(Style 6) This document is not 6820 Primary AC:120AC @ 60Hz,3.3A Total configuration for SLC,SBUS,and Flexput circuits intended to be used for Accessory Load:6A @ 27.4VDC power-limited installation purposes.We Standby Current:190mA WIRING:See the product manual for wiring details try to keep our product Alarm Current:250mA information up-to date and accurate.We Battery Charging Capacity:7 to 35AH cannot cover all specific Battery Size:18AH max.allowed in control panel applications or anticipate cabinet.Larger capacity batteries can be housed in all requirements.All specifications are subject RBB accessory cabinet. to change without notice. For Technical Support,call 800-446-6444. Honeywell Silent Knight 12 Clintonville Road Northford,CT 06472 Honeywell 800-328-0103 sststo I B I osna www.silentknight.com <>2018 Honeywell International Inc. .1JTGI I' Mil IUTIGHT "RACP" Main Entry(s) INTELLIKNIGHT ACCESSORY SILENT 5860 Remote Annunciator « . KNIGHT by Honeywell Bring the power to control an IntelliKnight fire alarm control panel to every area within your facility. Now you can operate and program your IntelliKnight system from up to eight locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy-to-use interface found on the IntelliKnight panel's built-in annunciator. The 80-character display and ergonomically designed keypad allow for simple and error-free system operation.All operations—including reset, silence, detector status checking, fire drill, and programming—are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the IntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description multiple 5860s Features include an 80-character • RS-485 interface to panel ¢r backlit LCD providing easy-to- • Operation and appearance is r i 'z,im, ` ,-,-:> ,,:,,, i wit understand system messages. The identical to 5860 built-in 'fi is / � f •�� tf annunciator is ergonomically annunciator , � ' designed with over-sized buttons • On-board piezo sounder audibly 1 «f`;« ° / p g //` indicates alarms, troubles, and , .' r am `' ` ' `' ° for the most frequently used ai t ,r features, like Reset and Silence. supervisories f� '�'x v. ., 1, « • ', ' , • Five status LEDs for alarm, ` ' •'. 3 V «` ,„ In addition to status messages supervisory, trouble, silence and Al'r ' .« h!` displayed on the LCD, there are AC power conditions �`''�� 3 ' a' , «« five LEDs for alarm, supervisory, • Wiring lengths up to 6000 ft. from trouble, silence, and AC power the FACP (depending on wire 5860 status. gauge and number of devices on The annunciator is available in gray SBUS) Environmental• UL listed, complies with NFPA 72 Operating Temperature: 32°F— to match virtually any decor and 120°F (0°C—49°C) red for applications where the • CSFM approved Humidity: 10% —93% non- annunciator must stand out. The Electrical Specifications condensing annunciator enclosure can be Operating Voltage: 24 VDC surface or flush mounted.A trim Standby Current: 20 mA max Compatibility ring kit is available for surface Alarm Current: 25 mA The 5860 is compatible is the mounting. following FACP's: Features Wiring Distance: 6,000 max. from • IntelliKnight 5820XL FACP FACP (depending on wire gauge • 80-character backlit LCD display and number of devices on the • IntelliKnight 5808 FACP (4 lines with 20 characters on SBUS) • IntelliKnight 5700 FACP each line) • Tactile and audible feedback Max Per System: 8 Approvals/Listings NFPA 72; UL Listed; • Accepts user codes or fire Mechanical Specifications CSFM 7170-0559: 135; fighter's key Physical 9.1"W x 7.4" H x 1.5" D • Larger keypad buttons for system (23.1 W x 18.8 H x 3.8 D cm) MEA 429-92 E Vol. IX; reset and silence FM Approved • Install up to eight 5860s per Shipping Weight: 2.8 lbs (1.3 kg) FACP Color • Available in red or light gray 5860R: Red 5860: Gray • Support for simultaneous use of INTELLIKNIGHT ACCESSORY 5860 Remote Annunciator Engineering Specifications The main control must have a built-in annunciator and must support up to eight remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built-in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built-in annunciator.All annunciators must have an 80-character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of .040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. Wire Runs Up to 6000 Feet From FACP SBUS �) 0 x li '14} 4 , 5860 5860 5860 Up to Eight 5860s Per System Compatible IntelliKnight FACP Ordering Information 5860R Remote Annunicator four line LCD annunciator with 20 characters per line. Red. 5860 Remote Annunciator.Four line LCD annunciator with 20 characters per line. Gray. Accessories 5860TR Red Trim Ring for surface mounting. 5860TG Gray Trim Ring for surface mounting. 1;::1SILENT This document is not intended to be used for installation purposes.We try MADE IN AMERICA oduomoodte e canot e KNIGHT allto specifickeepur appliprocacttionsinf orr anticipateatinup-t all- a requirements.andaccurat All.speciWeficantionscov are FORM#350224 Rev E subject to change without notice. For more information,contact Silent ©2010 Honeywell International Inc. by Honeywell Knight 12 Clintonville Road,Northford,CT 06472-1610. Phone: (800)328-0103, Fax: (203)484-7118. www.silentknight.com FIRE SYSTEM ACCESSORY Firepower 5496 rt), Distributed Power Module k J l .4, ,,' , . ,, A dynamic combination of power and intelligence f for your notification expansion needs. • ,, jf r» / ' itii ',. The Model 5496 Intelligent Power Module by Silent Knight is the most- ' powerful and cost-effective power supply available today. It delivers 6 amps of S notification appliance circuit power and built-in synchronization for appliances from Gentex®, Faraday, AMSECO and Wheelock®—what you need to drive power-hungry components like ADA notification appliances. The 5496's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. For the most sophisticated and cost-effective notification power supply available, you need Firepower 5496. Call Silent Knight today for more information at 1-800-446-6444. Model 5496 • 3 amps per output circuit Intelligent Power Module • Ground fault detector g • Communicates to the FACP via 4- The model 5496 is a 6 amp notification wire SBUS (wire runs up to 6000 ft) power expander that provides its own • AC loss delay option shuts off power AC power connection, battery charging to non-essential high-current circuit, and backup battery for use with accessories like magnetic door fire and security controls such as the holders IntelliKnight Model 5808 Fire Control • Lightweight design adds to ease of /Communicator. The 5496 is the cost installation and reduces shipping1 effective solution for powering notification appliances required by the costs • Americans with Disabilities Act(ADA). UL 864 & 1481 listed The 5496 has built-in ANSI cadence • CSFM approved pattern, which can upgrade older • ANSI Cadence pattern output control panels that lack cadence capability built-in capability. The Output circuits can be Specifications programmed as Notification Appliance AC Input 120 VAC at 2.7 A Itt k��"" Circuits, or as Auxiliary Power (configurable for, constant, resettable, Output: 24 VDC at 6 amps Model 5496 Intelligent or door holder power). Current: Power Module Features Standby 40 mA Battery charging Alarm 160 mA capacity: 33.0 AH • UL Listed for 6 amps of notification power Notification/Aux. Ambient Temp.: 32°to 120° F • Power supply's advanced switch Power circuits: 4 0°to 49°C mode design reduces damaging Output Dimensions: 12.25"W x 16"H x heat and manages power up to 50% configuration: 2 Class A(Style Z) 3"D(30.88 cm W more efficiently than other systems 4 Class B(Style Y) x 40.64 cm H x • Built-in synchronization for (1 Class A& 7.62 D cm) appliances from AMSECO, Gentex®, 2 Class B) Faraday, and Wheelock Amps per Approvals: UL • 24 VDC filtered output voltage output circuit: 3.0(6.0 amps total) NFPA 72 • Four power-limited notification Notification outputs; 2 Class A or 4 Class B, or 1 circuit output: 20.4 to 27.3 VDC Class A and 2 Class B @ 3.0 amps each, • NACs are programmable as 4.7 kS2 EOL resistor required SILENT Notification Appliance Circuits, or as on each Class B KNIGHT auxiliary power to be used as circuit 41011 constant, resettable, or door holder power FIRE SYSTEM ACCESSORY Firepower 5496 Distributed Power Module Engineering Specifications The contractor shall supply a power module compatible with the Silent Knight FACP. The power module must have 6.0 amps of output power. The power module shall connect to the main FACP via an RS 485 system bus (SBUS). The Outputs shall be programmable as Notification Appliance Circuits, or as Auxiliary Power (configurable for, constant, resettable, or door holder power). The power module shall have four separate outputs. The power module RS 485 bus shall be optically isolated providing ground loop isolation and transient protection. 4 outputs programmable as Notification Appliance Circuits, or as Auxiliary Power E,. Output 1 -, SBUS Communication to a compatible Output 2 . Silent Knight FACP 00' Output 3 ', Output 4 . Auxiliary power can be programmed to be, constant, resettable, or door holder power Compatible FACPs IntelliKnight 5808 IntelliKnight 5820XL 14 SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 MADE IN AMERICA `MOW' 800-446-6444 or in Minnesota 763-493-6435 FORM#350387, Rev. 04/02 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com Copyright©2002 Silent Knight 90. CELLULAR ALARM 4 ► TG ,.. 7Fs COMMUNICATOR TEL.GUARD P/LTELV01 FOR LTE NETWORKS a COMMERCIAL FIRE PRODUCT FEATURES I. Certified for use on Verizon's LTE network for long, sunset- free installation. I- Meets UL 864 requirements for sole, primary or backup path communications. I- Minimizes false alarms byprovidingdualpaths for self-tests. sts The Telguard TG-7FSLT E-V LTE V is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LTE-V transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2016 Edition of NFPA 72, the TG-7FS LTE-V can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LTE-V, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LTE-V can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LTE-V because of the new sixty minute supervision mode. The TG-7FS LTE-V can also be installed as a backup path and upgraded to sole path at a later date. Telguard Portal Telguard Cellular Service Advanced Reliability Telguard makes adopting cellular Telguard Cellular Service provides • Features the ability to utilize easy with a secure Internet portal. Verizon LTE network coverage multiple cellular technologies to The straightforward web interface for all Telguard units. Telguard's increase availability and reduce allows security dealers and central Communication Center is UL false alarms. stations to quickly and efficiently compliant and provides seamless • Automatic self-tests with central access Telguard based services 24/7. connectivity between the alarm station notification ensure the This advanced tool has multi-level panel, the Telguard family of cellular system is operating. user authorization and provides products and the central station. •of Telguard Technical SupportAvailable relay output for tripping total account management g provides UL Listed Telguard cellular alarm a single point of contact for both the alarm control panel when a communicators. cellular service and Telguard product trouble condition occurs. questions. „ , CELLULAR ALARM , , /�' 'r TG - 7FS COMMUNICATOR LTE -V FOR LTE NETWORKS T E LG U A R D P/N: TG7LVFO1 iin> Power ®� • Transmit Power: ® 11 200mW in all bands. ) III _ ii Power Consumption: II 60mA(Standby) ' 250mA(Transmission). • Transformer: 12VAC,800mA UL listed plug-in. Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power Radio Transceiver for superior in-building penetration. • LTE Bands:4&13. • Antenna:9” dipole with 2dBi gain Telguard products are easy to install, economical, and UL Listed. 12 ft of cable and universal mounting bracket. Accessories • FCC part 15,27 and 68 compliant. • ACD 12, ACD 35, ACD 50, ACD 100: iiiiiii12/35/50/100 feet of low loss, high performance cable. • HGDL-0: High gain directional antenna. Physical Details • EXDL-0: External antenna. • TG-7FS LTE-V: 7.5"H x 11,5"W x 3.5"D. • Shipping Weight: 81bs. • Operating Environment: 0°C to+50°C;up to 95%humidity (non-condensing). Standard Features UL Listings Commercial Fire 864 Commercial Burglary Residential • Full data reporting. • Control units& 365 • Police Station 985 • Household fire accessories for connected warning systems • Automatic self test(60 min.&daily). fire alarm systems burglar alarm 1023 • Household burglar • Power supply with battery harness. units and systems alarm systems • Locking, red metal enclosure. 1610 • Central station burglar • Two programmable supervisory alarm units; Line security servcies trip outputs. • Supports virtually all alarm formats ' For the most current product specifications and UL Listings visit www.Telguard.com. (Contact ID,SIA2,and others) using dial capture for universal SECURITY _, panel compatibility. SIGNALING GT] _ //�� • Telephone line monitor built-in, (� ) ; \I��: ,,,jkeowc Yer,Zen with Standard Line Security. a�-1' �/ �" �AssocinnoN NETWORK NFPA lil+ LISTED INTERNATIONAL CERTIFIED tliiid Telguard,a Division of Telular Corporation•3225 Cumberland Blvd SE•Suite 300•Atlanta,GA 30339• USA 800-229-2326,Option 5•www.Telguard.com •Copyright©2017 Telular Corporation•All Rights Reserved INTELLIKNIGHT ACCESSORY SILENT SK-PuII-SA and SK-Pull-DA KNIGHT by Honeywell Intelligent Pull Stations The SK-Pull-SA and SK-Pull-DA are a single action or dual action addressable fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SK-Pull-DA and SK-Pull-SA provide a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Pull-SA is a single action pull station requiring only FIRE , one motion to activate the station. The SK-Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight I PULL i DOWN Intelliknight series fire alarm control panels (FACPs). Features • Installer can open station without causing an alarm condition • Dual-color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition SK-PuII-SA • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks f I • Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG)controls and operating mechanisms 1 PUSH IN guidelines (Section 4.1.3[13]) [ TONI • Meets ADA requirement for 5 lbs maximum pull force to active • Shell, door, and handle molded from durable LEXAN® S1ft I. • Reliable analog communications for trouble-free operation • Braille text on station handle SK-PuII-DA • Handle latches in down position and the word Activated Compatibility appears, clearly indicating the station has been pulled The SK-Pull-SA and SK-Pull-DA are compatible • Rotary address switches for fast installation with the following IntelliKnight FACP's: 5600 • UL Listed, including UL 38, Standard of Manually Actuated 5700 5808 Signaling System 5820XL INTELLIKNIGHT ACCESSORY Model SK-Pull-DA and SK-Pull-SA Engineering Specifications The contractor shall furnish and install where indicated on the plans,Addressable Pull Stations, Silent Knight model SK-Pull-SA single action pull station or SK-Pull-DA, dual action pull station. SK-Pull-DA or SK-Pull-SA meet the ADAAG controls and operating mechanisms guidelines, and the ADA requirements for a 5 lb. maximum pull force to activate the pull station. rP, rag,EPfI}} NOW wro ki Nu'iv (fit, y Y L,' .....«...«.»_.»«.».«.«.» Class A..«_««,..........._..........»........».....«»..«.._»..�._.»»., Class S 1 Compatible FACP 1.dL ; i 1I r��� 1 I II rir�nEl I li oo n , , oAT , ) x Gass A Wiring: { ‘, 8 U I Class B Wring: ill '' iisa r — r IMring SK-Pull-SA&8K-Pull-DA Pull Stations Specifications Electrical Physical Operating Voltage: 15-32 VDC Height: 5.5"(14 cm) Average Operating Current(LED flashing): 300 pA Width:4" (10.2 cm) Wire Gauge: Up to 12 AWG (3.1 mm2) Depth: 5.4 oz. (3.7 cm) Environmental Housing Material: LEXAN polycarbonate resin Operating Temperature 32°— 120°F(0°C—49°C) Bi-Colored LED: Humidity: 10%—93% non-condensing Blinking Green: Normal Steady Red:Alarm Accessories Switch: Single pole, single throw(SPST)normally open (N/O) BG-TR Optional trim ring. switch which closes upon activation of the pull station SB-I/O Surface backbox This document is not intended to be used for installation purposes.We try to MADE IN AMERICA SILENTNI 41Ptill keep our product information up-to-date and accurate.We cannot cover all KNIGHT specific applications or anticipate all requirements.All specifications are subject to change without notice.For more information,contact Silent Knight FORM#350135 Rev A 12 Clintonville Road,Northford, CT 06472-1610 Phone: (800)328-0103, ©2009 Honeywell International Inc. by Honeywell Fax:(203)484-7118. www.silentknight.com Common Areas and Elevator Shafts/ INTELLIKNIGHT ACCESSORY Equip Rooms SK-Photo t: F, and Ph�T , Intelligent Photoelectric Smoke Sensors The SK-Photo is a photoelectric smoke detector and the SK-Photo-T is a photoelectric smoke detector with thermal. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight IntelliKnight Fire Alarm Control Panels (FACPs). For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103 or in Connecticut, call (203)484-7161. Description • Plug-in mounting provides ease of SK-Photo and SK-Photo-T are plug-in lu in installation type smoke sensors that combine a • Tamper-proof feature available on photoelectric sensing chamber with mounting bases addressable analog communications. • Listed for use in duct applications , ti t Point ID capability allows each ' , � " • Rota addressfor fast detector's address to be set with rotary �' switches �, - �' 1 : ` � , address switches, providing exact installationr detector locations for selective • UL Listed f .4 maintenance when chamber u,� e • FM Approved contamination reaches unacceptable /411 - levels. Specifications 1 11,14, SK-Photo and SK-Photo-T have a Physical / unique optical sensing chamber that is Height: 2.0"(5.0 cm) engineered to sense smoke produced by a wide range of combustion Diameter:4.1"(10.4 cm) sources. In the SK-Photo-T, dual Shipping Weight: 5.2 oz. (147 g) SK-Photo (Base included) electronic thermistors add 135°F(57°C) Electrical Compatibility thermal technology to maximize Operating Voltage: 15-32 VDC detection. Standby Current: The SK-Photo and SK-Photo-T are compatible with the following Features 300 pA @ 24 VDC Maximum IntelliKnight FACPs: • Sleek, low-profile design Alarm Current: 6.5 mA @ 24 VDC max 5700 • Base included (with LED on) 5808 • Reliable analog communications for Environmental 5820XL trouble-free operation Operating Temperature SK-Photo and SK-Photo-T are • Age resistant polymer housing SK-Photo: 32°— 120°F(0°C—49°C) compatible with the following detector SK-Photo-T: 32°— 100°F(0°C—38°C) bases: • Dual electronic thermistor design on Humidity: 10%—93% non-condensing B210LP (included)6" base the SK-Photo-T 8501 2 wire base Other Ratings B501 BHT-2 Temporal base • Superior EMI resistance for reliability SK-Photo-T Thermal: Fixed p B224RB Relay base • Simple field cleaning for code temperature set point 135°F(57°C) B224B1 Isolator base compliance Velocity: 0—4000 fpm (0—20 m/sec) B501 BH-2 Sounder base • Variety of mounting options to meet SK-Photo Insect Screen Hole Size: any application 0.016" (0.41 mm) nominal • Dual LED indicators for 360°visibility E211 SILENT • Detector transmits signal to indicate KNIGHT rWrr+� maintenance is required • Optional remote LED annunciator by Honeywell (System Sensor®PN RA100Z) INTELLIKNIGHT ACCESSORY Model SK-Photo and--SK-Pho-to--T Intelligent Photoelectric Smoke Sensors /,‘(.,$0411 Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent photoelectric smoke sensors Silent Knight SK-Photo or SK-Photo-T with thermal. The combination detector head, and twist-lock base, shall be UL listed and compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with SK-Photo or SK-Photo-T. Base shall be the appropriate twist-lock base part number B210LP (included). The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SK-Photo shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. St IN OUT i .,f04•a ......s• r_ i r itAinit(Opnorrai) al ,./. :7'111 ii,1\ del i;e. 1111111)117:%\\'..\,%,. ...1%.0 14. ...:,ir., , , { ,......,..., op. 4 . Lr ._ ._ r Wjnn2 SK-Se++ee l?etltxiw Mcmir+t►ng*soft SILENT TNo KNIGHT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA filZ" keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject FORM#350118 Rev A, woe to change without notice. For more information, contact Silent Knight 12 ©2009 Honeywell International Inc. by Honeywei Clintonville Road, Northford,CT 06472-1610 Phone: (800)328-0103, Fax: (203)484-7118. www.silentknight.com Elevator Shafts and Equip Rooms INTELLIKNIGHT ACCESSORY SILENT SK-Heat, - ---H-T ii4000 10 KNIGHT -ate by Honeywell -} - Addressable thermal heat and rate-of-rise detectors The SK-Heat, SK-Heat-HT, and SK-Heat-ROR are plug in thermal detectors, with integral communication, that provide features that surpass conventional detectors. These thermal detectors are for use with Silent Knight IntelliKnight series Fire Alarm Control Panels (FACPs). IntelliKnight heat detectors are an essential component in virtually any IntelliKnight installation. The IntelliKnight panel recognizes each detector by its specific address, so precious seconds are not wasted in determining location of an alarm. Description • Dual LED indicators for 360° SK-Heat, SK-Heat-HT and SK- visibility Heat-ROR are intelligent sensors • Detector transmits signal to ,:. that utilize astate-of-the art ,.1 thermistor sensing circuit for fast indicate maintenance is required i , ;fs• response. Sensitivity is • Plug-in mounting provides ease continuously monitored and of installation iii,,_ reported to the FACP. Point ID • Optional remote LED annunciator capability allows each detector's address to be set with rotary (System Sensors PN RA100Z) address switches, providingexact SK-Heat(base included) • Tamper-proof feature available on detector locations for selective mounting bases Thermal Ratings maintenance when chamber SK-Heat: Fixed temperature alarm contamination reaches • Rotary address switches for fast 135°F (57°C) unacceptable levels. installation SK-Heat-HT: High temperature heat SK-Heat is a fixed temperature • UL Listed sensor 135°F - 190°F (57°C - 88°C) sensor that uses a thermistor Specifications sensing circuit to produce 135°F SK-Heat-ROR: Rate-of-rise (57°C)fixed temperature alarm. Physical detection 15°F/min (8.3°C/min) Height: 2.0" (51 mm) SK-Heat-HT is a variable high Diameter: 6.1" (155 mm)installed in Compatibility temperature detector that provides B210LP base The SK-Heat, SK-Heat-HT and SK- high temperature detection at Shipping Weight: 4.8 oz (137 g) Heat-ROR are compatible with the 135°F - 190°F. (57°C - 88°C) Electrical following IntelliKnight FACP's: SK-Heat-ROR is a rate-of-rise Operating Voltage: 15 to 32 Volts 5700 temperature sensor with 135°F DC Peak 5808 (57°C)fixed temperature alarm. 5820XL Standby Current: 300pA @ 24 Features VDC The SK-Heat, SK-Heat-HT and SK- • Reliable analog communications LED Current: 6.5 mA@ 24 VDC Heat-ROR are compatible with the following detector bases: for trouble-free operation Environmental B210LP (included) 6" base • Age resistant polymer housing Operating Temperature B501 2 wire base • Innovative thermistor sensing SK-Heat& SK-Heat-ROR: B224B1 Isolator base circuit -4°— 100°F (-20°C—38°C) B224RB Relay base • Superior EMI resistance for SK-Heat-HT -4°— 150°F B200SR Sounder base reliability (-20°C —66°C) • Variety of mounting options to Humidity: 10% —93% noncondensing meet any application INTELLIKNIGHT ACCESSORY Model SK-Heat, SK-Heat-HT, SK-Heat ROR Addressable Thermal and Rate-of-Rise Thermal Detectors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent Thermal Sensor Silent Knight Model SK-Heat, SK-Heat-HT or SK-Heat-ROR. The base included shall be B210LP. The Heat detector shall have a flashing status LED for visual supervision. When the detector is activated, the flashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field removable when not required.Voltage and RF/transient suppression techniques shall be employed to minimize false alarm potential. SLC i IN OUT rf ';'mow a K,,tl' ` Compatible FACP ik .JPm ) RA100Z(Optional) r r NI . e:,,, ,...;„, te.)1,„, 7 ., ,.,„,,,....i..„„....„ \ow ‘lifik • _ii \ill?" ■ ■ Claw A Optional Wirng I Wiring SK-Series Detector Mounting Bases Accessories M02-09-00-Test Magnet with Telescoping Handle. RA100Z-Remote LED Annunciator. XP-4-Extension Pole for XR2B. Extends from 5— 15 ft. RMK400-Recessed Mounting Kit. Provides low profile for use with T55-127-000-Detector Removal Head. B501. XR2B-Detector Removal Tool.A removal and re-placement tool BCK-200B-Black Detector Kit. For SK-series detectors. for SK plug-in detectors. Includes the T55-127-000. *Unless otherwise noted,specifications apply to all SK thermal detectors. M02-04-01 -Replacement Test Magnet. SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA keep our product information up-to-date and accurate.We cannot cover all KNIGHT specific applications or anticipate all requirements.All specifications are FORM#350120 Rev. C subject to change without notice. For more information,contact Silent Knight ©2010 Honeywell International Inc. by Honeywell 12 Clintonville Road Northford, CT 06472-1610 Phone: (800)328-0103, Fax: (203)484-7118.www.silentknight.com Sprinkler & HVAC Supervising Module Honeywell Ste' KNIGHT SK-MONITOR-2 Addressable Dual Monitor Module The SK-MONITOR-2 module is capable of monitoring two separate Class B circuits simultaneously,making it ideal for waterflow tamper switch and flow switch monitoring. fir 4IPI' ' ,% 1111) The SK-MONITOR-2 is an addressable monitor module with two initiating ' circuits for use with Honeywell Silent Knight series fire alarm control panels '.. (FACPs).The SK-MONITOR-2 acts as an interface to contact devices,such • as waterflow switches and pull stations. •- <"� The SK-MONITOR-2 supports Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and • trouble conditions.. % • p INSTALLATION SK-MONITOR-2 mounts directly into a 4"square electrical box.The box SK-MONITOR-2 must have a minimum depth of 2-1/8".A surface mount electrical box (System Sensors part number SMB500)is available from Silent Knight. FEATURES & BENEFITS • Monitor two circuits, • Panel controlled • Rotary address with unique status LED that switches for fast addresses, flashes green in installation simultaneously normal state and is • SEMS screws for easy • Support for Class g solid red in alarm wiring wiring • Attractive ivory cover plate • Fully supervised SK-MONITOR-2 Technical Specifications To Next Device + For a complete listing of all f compliance approvals and n certifications,please visit r t O 0 �� www.silentknight.com. I Microsoft,Windows,and 1, TV the Windows Logo are ZIA Se TIN registered trademarks �M...n trademarks oftC M Miccroosoft Corporation. Oo o op] coiopat mc•FAO!. Knight"',System Two initiating device circuits NFPA U Ti3 Sensor'and Honeywell' Stlye B Power limited 230pA Max @ are registered 12VDC max n SIC r trademarks of Honeywell OUT IN International,Inc. (6 0 �1-- rirrin This document is not intended to be used for 1 n "ix ' installation purposes.We try to keep our product information up-to V date and accurate.We U cannot cover all specific applications or anticipate all requirements.All Wiring SK-Monitor-2 Modules specifications are subject to change without notice. PHYSICAL AGENCY LISTINGS AND APPROVALS For Technical Support, call 800-446-6444. Height:4.5"H x 4"W x 1.25"D UL Listed Shipping Weight:6.3 oz(196 g) CSFM Approved City of New York Approved ELECTRICAL Operating Voltage:1.5-32 VDC COMPATIBILITY Standby and Alarm Current:750pA max Ca?24VDC The SK-MONITOR-2 is compatible with the (one communication every 5 sec with 47K EOL) following Honeywell Silent Knight fire alarm End-of-Line Resistance:47KS1 control panels: 6820:Addressable fire alarm control panel ENVIRONMENTAL 6820EVS:Addressable fire alarm control panel Operating Temperature:32°F-120°F(0°C- with an emergency mass notification system. 49°C) 6808:Addressable fire alarm control panel Humidity:10%-930/0 non-condensing 6700:Addressable fire alarm control panel 5700:Addressable fire alarm control panel ORDERING INFORMATION 5808:Addressable fire alarm control panel SK Monitor-2:Dual Monitoring Module 5820XL:Addressable fire alarm control panel ACCESSORIES. 5820XL-EVS:Addressable fire alarm control panel SMB500:4"Square Surface Mount Electrical Box with an emergency mass notification system. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com � Honeywell Silent Knight Honeywell "` 12 Clintonville Road Northford,CT 06472 Doc 3501241 Rev E 1 11/17 SILENT' 800-328-0103 ©2017 Honeywell International Inc. ®KNIGHT HVAC and Door Holder Control Module Honeywell ['SILENT' Ki KNIGHT SK-RELAY Intelligent Relay Module The SK-RELAY is an addressable relay module for use with Honeywell Silent Knight Series fire alarm control panels(FACPs).The SK-RELAY allows a Silent Knight FACP to switch discrete contacts by code command.The (4) relay contains two isolated sets of Form C contacts,which operate as a DPDT switch.No supervision is provided for the notification appliance circuit. Honeywell The SK-RELAY contacts can be used for virtually any normally open or �icvu.rrr normally closed application.Each SK-RELAY is programmed with a unique signaling line circuit(SLC)loop address.When an event occurs that controls the SK-RELAY,the relay is triggered by the FACP + INSTALLATION The SK-RELAY mounts directly into a 4"square electrical box.The box must SK-RELAY have a minimum depth of 2-1/8".A surface mount electrical box(System Sensor'PN SMB500)is available from Silent Knight. FEATURES & BENEFITS • Two sets of Form C • Panel controlled • Polling LED visible contacts status LED that through the cover • Rotary address flashes green in plate switches for fast normal state and is • SEMS screws for easy installation solid red in alarm wiring • Contacts are rated for • Relay programming is • UL Listed a variety of amps(see completely flexible Specifications) can be mapped to zone conditions SK-RELAY Technical Specifications For a complete listing of all compliance approvals and certifications,please visit PHYSICAL ORDERING INFORMATION www.sitentknight.com. 4.675"H x 4.275"W x 1.4"D SK-RELAY:Relay Module Shipping Weight:6.3 oz(196 g) Microsoft,Windows,and ACCESSORIES. the Windows Logo are registered trademarks ELECTRICAL SMB500:4"Square Surface Mount Electrical Box or trademarks of Operating Voltage:15-32 VDC CB500:Module Barrier Microsoft Corporation. End-of-Line Resistance:Not used Silent Knight',System SLC Standby&Alarm Current:.255mA max® COMPATIBILITY Sensor'and Honeywell' 24VDC(one communication every 5 sec with LED The SK-RELAY is compatible with the following are registered enabled) Honeywell Silent Knight fire alarm control panels: trademarks of Honeywell 6820:Addressable fire alarm control panel International,Inc. ENVIRONMENTAL 6820EVS:Addressable fire alarm control panel This document is not Operating Temperature:32°F-120°F(0°C- with an emergency mass notification system. intended to be used for 49°C) 6808:Addressable fire alarm control panel installation purposes.We Humidity:10%-93%non-condensing 6700:Addressable fire alarm control panel try to keep our product information up-to RELAY CONTACT RATINGS 5700:Addressable fire alarm control panel date and accurate.We 5808:Addressable fire alarm control panel cannot cover all specific 3.0A C 30VDC resistive applications or anticipate 0.9A®110VDC resistive 5820XL:Addressable fire alarm control panel all requirements.All 0.9A 125VAC resistive 5820XL-EVS:Addressable fire alarm control panel specifications are subject with an emergency mass notification system. to change without notice. 0.5A®125VAC inductive(PF=.35) 0.7A@ 75VAC inductive(PF=.35) For Technical Support, call 800-446-6444. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight Honeywell 12 Clintonville Road Northford,CT 06472 Doc 350127I RevGI 11/17 SILENT 800-328-0103 ©2017 Honeywell International Inc. ®KNIGHT Units : Ceiling Mount Low Frequency Horn 44. GENTEX CORPORATION Low Frequency Audible Signal GHLF Applications 24VDC The GHLF is a high quality, low profile, low frequency audible appliance that offers a dependable audible alarm with a low current draw. The GHLF is ideal for any S E R ' E S occupancy that requires notification appliances. The GHLF horn offers a 520 Hz square wave,temporal 3 tone. A jumper selection is available for normal or loud decibel tone. A temporal 4 pattern is available when used with the Gentex GTSM Synchronization Control Module. The GHLF is shipped with a standard 4" metal mountingplate which incorporates the � t P popular Super-Slide®feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The GHLF also features the patented Checkmate®- Instant Voltage Verification feature which allows the installer to check the voltage drop and match it to the blueprint. The GHLF horn is listed to ANSI/UL 464 and CAN/ULC S525, is listed for use with fire Product Listings protective systems and is warranted for three years from date of purchase. SIGNAUNG Standard Features74 • Nominal voltage 24 VDC • Input terminals accept 12 to 18 AWG C a US j1i) • Unit Dimensions:6-1/8"(15.55 cm)high x • Produces a 520Hz square wave,temporal 3 LISTED 5-1/2"(13.97 cm)wide x 1-5/8"(4.13 cm) tone deep • Jumper selection for normal or loud dBA • ANSI/UL 464 Listed •• Super-Slide®Bracket-Ease of Supervision • Temporal 4 pattern available when used CANNLC ends Listed • Testing with Gentex GTSM Synchronization Module CSFM: Pending • Checkmate®-Instant Voltage Verification • Temporal 4 520Hz measured per Product Compliance • Synchronize horn with Gentex GTSM ANSI/UL 2075 • NFPA 72 Synchronization Control Module • Tamperproof re-entrant style grill and • IBC/IFC/IRC • Prewire entire system,install mounting locking screw(optional use) • Quality Management System bracket,then install signals • Faceplate available in red or off-white is certified to:ISO 9001:2008 Model Number Part Number Nominal Voltage Model Designations: R=Red Faceplate MEMBER GHLFW 904-0530-002 24 VDC W=White Faceplate < ASSEMBLED IN GHLFR 904-0531-002 24 VDC All units are plain(no lettering) THE USA Horn Decibel Levels: - 24VDC Nominal Horn Horn Current Ratings Reverberant Room Current Ratings(mA) Over Input Voltage Range of 16-33V(mA) Minimum SPL Minimum SPL 24VDC 24VDC 24VFWR 24VFWR Regulated Regulated Regulated Regulated at 10Ft.Per at 10Ft.Per Operating Operating Operating Operating 24VDC Max. 24VDC Max. 24VFWR Max. 24VFWR Max. Horn Mode ANSI/UL 464 ANSI/UL 464 Current Current Current Current Operating Operating Operating Operating (NORMAL) (LOUD) (NORMAL) (LOUD) (NORMAL) (LOUD) Current Current Current Current (NORMAL) (LOUD) (NORMAL) (LOUD) Temporal 3 520 Hz 77.8 dBA 7• 9.8 dBA 7• 2.1 mA 120.1 mA 104.6 mA 158.4 mA 99.4 mA 155.8 mA 152.1 mA 2• 13.5 mA Temporal 4 520 Hz* 81.5 dBA 8• 3.4 dBA 7• 5.9 mA 116.0 mA 108.1 mA 182.0 mA 100.1 mA 157.2 mA 163.1 mA - 2• 35.2 mA `Temporal 4 520 Hz measured per ANSI/UL 2075 NOTES: • Operating temperature:32"to 120"F(0"to 49°C).The GHLF is not listed for outdoor use. "`"W'*' • For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered(FWR[Full Wave Rectified])power,see installation manual. • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. ' RMS current ratings are per ANSI/UL average RMS method. ANSI/UL max current rating is the maximum RMS current within the listed voltage range(16-33VDC for 24VDC units). For unfiltered FWR ratings,see installation manual. 7; ,// I?, 'r l r;yii�d71 tr jt1,Jl t lti�f I�i� P, l�rrr rzl/' �11/ �l ul' yrtnr "• , ta NOTES: UL Listed • THIS APPLIANCE IS NOT RECOMMENDED FOR USE ON CODED OR Control Signal signal PULSING SIGNALING CIRCUITS Panel s+ s+ S- H+ H- S+ S+ s- H+ H- • THE FOUR PULSE TEMPORAL PATTERN(TEMPORAL 4)CAN ONLY BE Supervised ► O. ;, 0 0 0 0 ;, 0 0 OBTAINED ON THIS PRODUCT WHEN USED IN CONJUNCTION WITH Signal Circuit " " THE GENTEX GTSM SYNCHRONIZATION MODULE \ 0 • SEE GTSM CONTROL MODULE MANUAL(550 O6 2,MANUAL ISSUE ENO RESISTOROF E DATE(02-01-15)FOR SYNCHRONIZATION MOD E WIRING DIAGRAMS. 0 GTSM MANUAL CAN BE OBTAINED AT WWW. NTEX.COM/FIRE OR CALL GENTEX CORPORATION AT 1-800- -8391. DC)NM Malt 71e r-N CD SC ,I' 411Sb E' LOCKING 8+ I SCREW ' I l.—.1 r j CO 0 8P s (optional) L'— -�,-1� +- S , .----t _—..1 •11 p i\ l 1- .— El] i RED WIRES !s, l —►rl t1 011!r - 0 BLACK WIRES p;; l C i r --- -` m Il O r L�wt� I.h Ili — , _ ____,:/ ill \ 411 o ���/1 �o o NORMAL-LOUDI »»• ��, \� o `-�p.J� j DECIBEL JUMPER. Qmar �0 FOR LOUD DECIBEL 1.- t 11 11 II 11 4 INSTALL JUMPER. SLIDE ONTO BRACKET Gentex Checkmate® Gentex Super-Slide® LOCKING �l'%►� Instant Voltage Verification: Mounting Bracket: SCREW i���� (----,- . It is often necessary to confirm the voltage drop Allows the installer to pre-wire the system, (optional) "" along a line of devices.The access holes are test for system supervision,remove the r provided in the back of the terminal block to signal head until occupancy,switch out \It' allow the voltage to be measured directly without Gentex signals without changingIi removing the device.Typically this would be done mounting brackets and has locking edge �r ' i at the end of the line to confirm design criteria. connector for snap-in-place installation. ,- _II Most measurements will be taken using the S+and S-locations although access is provided to other locations.NOTICE:CARE SHOULD BE TAKEN TO NOT SHORT THE TEST PROBES. Architect & Engineering Specifications The alarm horns shall be Gentex model GHLF.The appliance shall be listed with Underwriters Laboratories(ANSI/UL)for use with fire protective signaling systems (ANSI/UL 464) and with CAN/ULC S525 with intended use in fire alarm systems. The GHLF will produce a peak sound output of 88.3 dBA as measured in an anechoic chamber. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate. The GHLF shall be mounted on the wall or the ceiling. The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power at 24 VDC. The appliance shall be capable of testing supervision without disconnecting wires,verify voltage without removing unit and be capable of mounting to a surface back box. 24 units per carton Important Notice. G H LF-01 GENTEX These materials have been prepared by Genies Corporation("Gentex")for informational purposes only,are necessanty summary,and are not purported to serve as legal advice and should not be used as such. Gentex makes no representations and warranties,express or implied,that these materials are complete and 'Wm. CORPORATION accurate.up-to-date,or In compliance with all relevant local,state and federal laws,regulations and rules. The materials do not address all legal considerations as there is inevitable uncertainty regarding interpretation of laws,regulations and rules and the application of such laws,regulations and rules to Fire Protection Products Group•www.gentex.com particulartact patterns.Each persons activities can differently affect the obligations that exist under applicable laws,regulations or rules.Therefore,these materials should be used only for informational 10985 Chicago Drive •Zeeland, Michigan 49464 purposes and should not be used as a substitute for seeking professional legal advice.Gentex will not be responsible for any action or failure to act in reliance upon the information contained in this material 616.392.7195 • 1.800.436.8391 •616.392.4219 Fax Gentex Corporation reserves the right to make changes to the product data sheet at their discretion. Interior Common Area Ceiling Mount •udible/Visual Alarm Device • GENTEX CORPORATION II Smarter Vision" Commander4 Series Selectable GCC/GCS Ceiling Mount Strobe and Horn Strobe 24 VDC Applications SERIES The GCS/GCC Series is a ceiling mount strobe or horn/strobe combination that offers dependable audible and visual alarms and the lowest current available. The GCS/GCC offers tamperproof field selectable candela options of 15, 30, 75, 95, 115 and 150 candela. The GCC horn offers a continuous or synchable temporal three in 2400Hz or mechanical tone. These tones are easy for the professional to change in the field by using switches. The models are shipped from the factory in the +it..� r. . ,, temporal three alarm mode. , `> The GC Series has a minimal operating current and has a minimum flash rate of 1 Hz regardless of input voltage. The Commander4 Series comes standard with the 4" mounting plate which r°>' incorporates the popular Super-Slide'"feature that allows the installer to eas ,a.F 4'"" ily test for supervision. The Commander4 also features the CheckmateTM- Instant Voltage Verification feature which allows the installer to check the voltage without Product Listings removing the signal. 4010 S ti. The GC Series appliances are UL 464 and UL 1971 listed for use with fire ' ^ C US protective systems and are warranted for three years from the date of pur- I APPROVED Thus symbol or hn{nocuc'x nsmep4Ne moans A us chase. ,..led by UNDERWRITERS LABORATORIES INC • BFP(City of Chicago) Standard Features • BS+A/MEA#285-91-E • Nominal Voltage 24 VDC • CSFM 7135-0569:122 (GCC) • Tamperproof Field Selectable Candela options of 15, 30, 75, 95,115 & 150 7125-0569:123 (GCS) • FM Approved • Super-SlideTM Bracket - Ease of Supervision Testing • UL 464 & UL 1971 Listed • CheckmateTM- Instant Voltage Verification • CAN/ULC S526-M87 Listed • Unit Dimensions: 6" x 2.6" ULSZ7.S3406 Listed (GCC) • Synchronize GC Series by using Gentex Series Control Module • Prewire Entire System, then Install Your Signals Product Compliance • Input Terminals 12 to 18 AWG • Switch Selection for High or Low dBA • NFPA 72 • Switch Selection for 2400Hz or Mechanical Tone • Americans with Disabilities Act(ADA) • Switch Selection for Continuous or Temporal 3 • Tamperproof Re-entrant Grill ?� • Surface Mount with the GCSB (Gentex Ceiling Surface Mount Box). MEMBER ASSEMBLED IN '"' ' • Silence Horn While Strobes Remain Flashing THE USA • Wide Voltage Range 16-33 VDC or FWR • Faceplate Available in Red or Off-White +rufetYUYYtNaliultteNx/W/fa)!N{YLaWNYi#iUYfWulMlttS igfiUxlutstGexllY" GCS 24 Volt Ceiling Mount Selectable Strobe Model Number Part Number Nominal Voltage Candela U CS24CR 904-1213-002 24 VDC 15, 30, 75, 95. 115, 150 Strobe Only UCS24CW 904-1215-002 24VDC 15, 30, 75, 95, 115, 150 < U CS24PCH 904-1214-002 24VDC 15, 30, 75, 95, 115, 150 GCS24PCW 904-1216-002 24VDC 15, 30, 75, 95, 115, 150 GCC 24 Volt Ceiling Mount Selectable Horn/Strobe Model Number Part Number Nominal Candela Reverberant In Anechoic Voltage dBA @ 10ft. Room dBA Per UL 4641 @10ft. ZiCC24CR 904-1209-002 24 VDC 15, 30, 75. 95, 115, 150 81-86 90 ZGC24PCH 904-1210-002 24 VDC 15, 30, 75, 95, 115, 150 81-86 90 Horn Strobe GCC24CW 904-1211-002 24 VDC 15, 30, 75, 95, 115, 150 81-86 90 GCC24PCW 904-1212-002 24 VDC 15, 30, 75, 95, 115, 150 81-86 90 Notes: •The GC Series is not listed for outdoor use. •Operating temperature: 32°to 120°F (0°to 49°C) • For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual. •Gentex does not recommend using a coded or pulsing signaling circuit with any of our strobe products(see technical bulletin number 014 for more information). Model designations: "P" = Plain (no lettering) "C" =Ceiling Mount, "R" = Red Faceplate/"W" =Off-White Faceplate GCS/GCC Product Strobe Current Ratings Candela 15cd 30cd 75cd 95cd 115cd 150cd 24 VDC 72mA 101 mA 167mA 200mA 214mA 286mA UL Max2 120mA 130mA 247mA 318mA 360mA 454mA Horn Mode Minimum dBA Minimum dBA Regulated 24VDC @ 10ft. per @ 10ft. per Max. Operating UL464(HIGH) UL464(LOW) @ High Setting (mA) Temp 3 2400Hz 83 75 23 Temp 3 Mechanical 81 73* 22 Continuous 2400Hz 86 78 23 t ontinuous Mechanical 84 76 22 *Operating the horn in this mode at this voltage will result in not meeting the minimum UL reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application. Notes: The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. To obtain the horn/strobe current draw, add the strobe current draw and the horn current draw. 1 The listed horn current draws are for the Continuous Tone mode. The Temporal 3 Tone has a reverberant dBA @ 10ft. per UL 464 is 77-83 with a horn current draw of 34mA. 2 RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33VDC for 24VDC units) (8-17VDC for 12VDC units). For strobes the UL max current is usually at the minimum listed 'tom' voltage (16VDC for 24VDC units) (8VDC for 12VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings, see installation manual. Mounting Super-SlideTM Ve 3. SNAP COVER OVER ASSEMBLY 2. INSERT LOCKING SCREW / ire I I I I.I IIII!!!. .4%fi n b . IA 41110111k.. Ilj�li► it ks Pill" eo..*N li �, l' qiirt1IIIIIU1� IIr`i1fr.,.._ Ir."1 -7-...-rallit . .vemeem.4 II► ._ (., o!+ ,�� __. ally i 1. SLIDE ONTO BRACKET CheckmateTM Instant Voltage Verification Switch Locations DO NOT PAINT / 1 2 3 4 5 cop R y G T Lt-�' 1 RFD WIRES R ,' Sis .- R�',e O f Jl LW 4 • U...�.. 'j OO O 1;m $- s 15 o 1® IMMIIIMMIIIMI ,1 BLACK WIRES ,1- �� -r ' A 0 o 6 0 ..® i M IMP The access holes are provided in the back of the terminal block to allow the voltage to be measured directly without removing Switch positions 1 and 2 in the down position to select the device.Typically this would be done at the end of the line to isolated horn and strobe power inputs. Switch 3 confirm design criteria. Most measurements will be taken using selects between temporal or non-temporal tone. Up is the S+ and S- locations although access is provided to other temporal. Switch 4 selects between mechanical or locations. NOTE: Care should be taken to not short the test high frequency tone. Up is mechanical. Switch 5 probes. selects between high or low dBA. Up is high dBA. Conventional GCS/GCC Wiring Diagrams UL Listed Control UL Listed Panel Signal Signal Control S. S+ S- H+ H- S. S+ S- H+ H- Signal Signal Supervised ►� y f1 i.nliaii Panel g+ g+ S- H+ H- S+ S+ S- H+ H- Signal Circuit Supervised 9 S 9 9 0 6 9 9 © "I"' 111111 Signal Circuit III \ 0 "" I"' END OF RESISTORE \ Ci / ERE OF LIN SISTOREI MI O \ O END OF 0 it r rE' ! Wiring Diagram GCS/GCC Series with Gentex Synchronization Module F.A.C.P. 00I ENO TOR NE FOR + TO NEXT SIGNAL TO NOTIFICATION ALARM CIRCUIT RESISTOR CUSS A RARING ONLY - iI TO NEXT SIGNAL' TO NOTIFICATION ALARM CIRCUIT REMOVE JUMPER NCHORINDEPENDENT �Jt 0 0 `'T SYNCHRONIZEDORERATION �(J C.' AUDIBLE SIGNAL°i ESI OF FOR AND HORN OPERATION - �'+•��• .m�a.+•.w�- CIRCUIT RESISTOR P SYNCHRONIZATION LEAVE JUMPERIN PLACE WRINGTO ELIMINATE NEED FOR MODULE LEAVE JUMPER IN PLACE ON 00 0 HORN INPUT ON AVSM 9LI1VE UNITS UNLESS SEPARATE / AND OPERATE SIGNAL w CONTROL OVER HORN < IN UNISON MODE 11 m 0 IS REQUIRED. SYNCHRONIZATION MODULE Signal Signal S+ S+ S H+ H- Tp s s el Is s e el VISIBLE SIGNAL®+ I ��- ENO OF LINE RESISTOR FOR CIRCUIT I I I I CUSS E 0 y — A9 1 y WIRING ONLY t I I ENO OG LINE RESISTOR TOR I CUSS WIRING ONLY. J r Note: See Technical Bulletin 015 for proper synchronization module for application. Ia Architect & Engineering Specifications The visible and audible/visible signal shall be Gentex model GCS or GCC or approved equal and shall be listed by Underwriters Laboratories Inc. per UL 1971 for the GCS and also UL 464 for the GCC.The notification appliance shall also be listed with the California State Fire Marshal (CSFM) and the Bureau of Standards and Appeals (NYC). The notification appliance (combination audible/visible units only)shall produce a peak sound output of 90dBA or greater as measured in an anechoic chamber.The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires.Additionally, the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 2Hz regardless of power input voltage. The appliance shall have an operating current of 72mA or less at 24 VDC for the 15 Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting brack- et with terminals with barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox with the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power. The appliance shall be capable of test supervision without disconnecting wires. Also the appliance shall be capable of mounting to a sur- face box. The unit shall also be able to verify voltage at the unit without removing unit. 24 units per carton 29 pounds per carton Important Notice: G E N T E X These materials have been prepared by Gentex Corporation('Gentex')for informational purposes only,are 5 51 0051-02 necessarily summary,and are not purported to serve as legal advice and should not be used as such. Gentex makes no representations and warranties,express or implied,that these matedals are complete 'ram CORPORATION and accurate,up-to-date,or in compliance with at relevant local,stale and federal laws,regulations and rules.The materials do not address all legal considerations as there is inevitable uncertainty regarding interpretation of laws,regulations and rules and the application of such laws,regulations and rules to panic- Fire Protection Products:www.gentex.com ular fact patterns. Each person's activities can differently affect the obligations that exist under applicable laws,regulations or rules. Therefore,these materials should be used only for informational purposes and 10985 Chicago Drive Box 310 •Zeeland, Michigan 49464 should not be used as a substitute for seeking professional legal advice.Gentex will not be responsible for any action or failure to act in reliance upon he information contained in this material.616.392.7195 • 1.800.436.8391 •616.392.4219 Fax Gentex corporation reserves the right to make changes to the product data sheets at their d scretion. C,Printed on Recycled Paper Exterior Wall Mount AV Horn/Horn- Strobe WGES / WGEC Series Outdoor Evacuation Signals 24 VDC Outdoor Commander Strobe and Horn/Strobe 1 unit per carton,3 pounds per carton Applications sf� ( The Outdoor Commander Series is a outdoor listed strobe and horn/strobe f a tl comination that offers dependable visible and/or audible alarms for all outdoor ! 5 mologir needs. r The WGE Series offers a fixed 75 candela strobe. The WGEC horn/strobe offers a continuous or synchable temporal 3 in 2400Hz,mechanical and chime as well as a whoop tone.All tones are easy for the professional to change in the field by the use of r^ switches. , •'+r ; +r .p 4 Included with the WGE Series is the GOE or GOELP outdoor enclosure.The enclosure 10,1010 is made of high quality Lexan®material,providing protection from weather related conditions and allowing the necessary full candela output.This highly constructed enclosure meets various installation requirements including deterring moisture from entering the enclosures. The Outdoor Commander Series is equipped with a standard 4"mounting plate which incorporates the Super-Slides feature that allows the installer to easily test for supervision.The product also features a locking mechanism which secures the product to the bracket without any screws showing. The WGE Series also features the Checkmates instant voltage verification feature which allows the installer to check the voltage drop draw and match it to the blueprint. The WGE Series appliances are ANSI/UL 464,ANSI/UL 1638, CAN/ULC 5525 and/or CAN/ULC S526 listed for use with fire protective systems and are warranted for three years from date of purchase. Product Listings SIGNALING Standard Features • Nominal voltage 24 VDC US • Fixed 75 candela C LISTED 1 • GOE Unit Dimensions:5.84"(14.83 cm)high x 4.81"(12.22 cm)wide x 4.22"(10.72 cm)deep • ANSI/UL 464 and ANSI/UL 1638 Listed • GOELP Unit Dimensions:5.84"(14.83 cm)high x 4.81"(12.22 cm)wide x • CAN/ULC 5525 and/or CAN/ULC S526 Listed 3.25"(8.255 cm)deep • CSFM:7135-0569:122(WGEC) • Super-Slides-Ease of Supervision Testing 7125-0569:127(WGES) • Checkmates Instant Voltage Verification 7300-0569:124(ENCLOSURE) • Prewire entire system,install mounting bracket,then install signals • MEA: 285-91E-XVI • Input terminals accept 12 to 18 AWG • Horn/strobe switch selection for high or low dBA Product Compliance • Horn/strobe switch for 2400 Hz,mechanical,chime and whoop tones • Horn/strobe switch for continuous or temporal 3(not available on whoop tone) • NFPA 72 • Synchronize strobe and/or horn by using Gentex AVSM Control Module ▪ Americans with Disabilities Act(ADA) • Silence audible while visual appliance will remain flashing • IBC/IFC/IRC • Tamperproof re-entrant grill and locking screw(optional use) • Quality Management System is certified to: • GOE/GOELP made of clear Lexan®-provides maximum visibility and reliability for ISO 9001:2008 effective visible signaling-allowing full 75cd output • Faceplate available in red or off-white I • Wall mount GENTEX rea- Assembled 111 CORPORATION 1 in the USA GEH Low Profile Evacuation Horn rkil t W�' Reverberant Anechoic Room � Model Part Number Voltage(VDC) dBA at 10ft. dBA at 10ft. GEH24-1( 904-1205-002 24 70-82 dBA 100 dBA GEH24-W 904-1207-002 24 70-82 dBA r 100 dBA NOTE:Must order the GOE or GOELP(sold separately)when using the GEH24 in an outdoor application. WGES24 Evacuation Outdoor Strobe Model Part Number Voltage(VDC) Candela WGES24 75WR i 904-1219-002 24 75 WGES24-75WW l 904-1220-002 i 24 75 WGES24-75WRLP 904-1261-002 24 75 WGES24-75WWLP ; 904-1263-002 24 75 WGEC24 Evacuation Outdoor Horn/Strobe Reverberant Anechoic Room Model Part Number Voltage(VDC) Candela dBA at 10ft. dBA at 10ft. WGEC24-75WR l 904-1217-002 I 24 75 ' 70-82dBA ! 100dBA WGEC24-75WW 904-1218-002 24 75 70-82 dBA 100 dBA WGEC24 75WRLP 904-1257-002 j 24 I 75 70-82 dBA 100 dBA WGEC24-75WWLP 904-1259-002 24 j 75 70-82 dBA 100 dBA R=Red Faceplate,W=White Faceplate LP=Low Profile(GOELP Enclosure) All units are available in plain(no lettering) Plain units are not returnable ;I: WGES/WGEC is shipped with the GOE or GOELP Outdoor Enclosure WGE 24 VDC Series Strobe Current Ratings Candela 24 VDC UL Max 75 cd 112 mA 170 mA WGE 24 VDC Horn Decibel(dBA)and Current Ratings(mA) Horn Decibel Horn Current Levels(dBA) Ratings(mA) UL MAX Minimum Minimum Regulated SPL at 10ft. SPL at 10ft. 24 VDC per per Operating ANSI/UL 464 ANSI/UL 464 Current Horn Mode (HIGH) (LOW) (HIGH) Temp 3 2400Hz 78 dBA 71 dBA* 28 mA Temp 3 Mechanical 76 dBA 70 dBA* 25 mA Temp 3 Chime 70 dBA' 66 dBA* 15 mA Continuous 2400Hz 81 dBA 74 dBA* 28 mA Continuous Mechanical 80 dBA 72 dBA* 25 mA Continuous Chime 70 dBA* 66 dBA* 15 rnA Whoop 82dBA 69dBA* 56mA *Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application(not applicable when using the chime tone. The chime ktilliiii tone is always private mode). WGES/WGEC -Outdoor Evacuation Signals • © 'o ii 5.84" _ 1 14.83 cm c--' , —\'''' ; V 41111111111111111111 4.81" H 4.22" 4 12.22cm 10.72cm Gentex Super-Slide® Mounting Bracket UL Listed Allows the installer to prewire the system,test for system Control signal Signal supervision,remove the signal head until occupancy,switch out Panel s+ s+ S- H+ H- s+ s+ s- H+ H- Gentex signals without changing mounting brackets and has Supervised S 6 S S 6( IS g S 0 B Signal Circuit locking edge connector for snap-in-place installation. AY ENO ONE 0 ______#______ 3 RESISTOR Gentex Checkmate° Instant Voltage Verification It is often necessary to confirm the voltage drop along a line of devices.The access holes are provided in the back of the terminal TOP r'''' block to allow the voltage to be measured directly without removing the device.Typically this would be done at the end of the0 0 line to confirm design criteria.Most measurements will be taken 0 0J-_-_ ) using the S+and S locations although access is provided to other n locations.Notice:Care should be taken to not short the test probes. <j= o ,-1' I"1`\ 1II V Notes E i,<<��' The WGE Series is listed for outdoor use. Indoor operating . 1l'.(r)w IIH+ III 32°to 120°F(0°to 49°C). Outdoor operating r ' temperature:-31°to 150°F(-35°to 66°C) l��� p- • For nominal and peak current across ANSI/UL regulated voltage 'A -I�I ����� range for filtered DC power and unfiltered(FWR[Full Wave i ,1'•. 11—- ii q Rectified])power,see installation manual • The sound output for the temporal 3 tone is rated lower since C :2Hi Cl DU 1311) c3 the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode,its C g. ®T PANT 0 sound pressure is the same as the continuous mode. • This appliance is not recommended for use on coded or pulsing signaling circuits WG ES / WG EC Series Outdoor Evacuation Signals Architect & Engineering Specifications The audible and/or visible signal shall be Gentex WGES,WGEC Outdoor Evacuation Signal Series or approved equal and shall be listed by Underwriters Laboratories Inc.per ANSI/UL 1638 and/or ANSI/UL 464 and CAN/ULC 5526 and/or CAN/ULCS525. The notification appliance (WGEC)shall produce a peak sound output of 100dBA or greater at as measured in an anechoic chamber and shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires.Additionally,the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. The audible/ visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 2 Hz regardless of power input voltage. The appliance shall have an operating current of 170mA or less for the 75Cd strobe circuit. The appliance shall also be capable of meeting the candela requirements of the ADA(75cd). The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals with barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current of full wave rectified power for 24 volt models. The appliance shall be capable of testing supervision without disconnecting wires.Also the appliance shall be capable of mounting to a surface back box. The unit shall also be able to verify voltage at the unit without removing unit. The appliance has extended temperature range of-31°to 150°F(-35°to 66°C). The appliance shall satisfy virtually all outdoor and severe environment applications. The GOE Enclosure is includes a gasket that must be inserted between the box and mounting bracket. There are drain holes in the back box to allow for drainage,the seal on the GOE Enclosure is not water tight.The GOELP Enclosure includes a weather seal for mounting to wall and intended for use with universal electrical box. To allow for drainage,bottom edge of enclosure is not water tight. GENTEX Fire Protection Products Group 110985 Chicago Drive I Zeeland,MI 49464 551-0047-04 i, . CORPORATION gentex.com I Phone:616.392.7195 I Toll-free:800.436.8391 I Fax:616.392.4219 Important Notice:These materials have been prepared by Gentex Corporation("Gentex")for informational purposes only,are necessarily summary,and are not purported to serve as legal advice and should not be used as such.Gentex makes no representations and warranties,express or implied,that these materials are complete and accurate,up-to-date,or in compliance with all relevant local,state and federal laws,regulations and rules.The materials do not address all legal considerations as there is inevitable uncertainty regarding interpretation of laws,regulations and rules and the application of such laws,regulations and rules to particular fact patterns.Each person's activities can differently affect the obligations that exist under applicable laws,regulations or rules. Therefore,these materials should be used only for informational purposes and should not be used as a substitute for seeking professional legal advice.Gentex will not be responsible for any action or failure to act in reliance upon the information contained in this material.Gentex Corporation reserves the right to make changes to the product data sheet at their discretion. • P POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC UL,ULC,and FM Approved Sizes Available: 6"(150mm),8"(200mm)and 10"(250mm) Voltages Available: 24VAC 120VAC 12VDC(10.2 to 15.6)Polarized 24VDC(20.4 to 31.2)Polarized Service Use: Fire Alarm General Signaling t,"'!'. Burglar Alarm !'` Environment: Indoor or outdoor use(See Note 1) -40°to 150°F(-40°to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells-4 No. 18 AWG stranded wires 0 DC Bells-Terminal strip ® Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox Model BBX-1 deep weatherproof backbox These vibrating type bells are designed for use as fire,burglar or general Notes: signaling devices. They have low power consumption and high decibel 1. Minimum dB ratings are calculated from integrated sound pressure ratings.The unit mounts on a standard 4"(101mm)square electrical box measurements made at Underwriters Laboratories as specified in UL for indoor use or on a model BBK-1 weatherproof backbox or BBX-1 Standard 464. UL temperature range is-30°to 150°F(-34°to 66°C). deep weatherproof backbox for outdoor applications. Weatherproof 2. Typical dB ratings are calculated from measurements made with a backbox model BBK-1,Stock No. 1500001. conventional sound level meter and are indicative of output levels in an actual installation. 3. ULC only applies to MBA DC bells. Size inches Voltage Model Stock Current Typical dB at Minimum dB at (mm) Number Number (Max.) 10 ft.(3m)(2) 10 ft.(3m)(1) 6(150) 12VDC MBA126 1750070 .12A 85 76 8(200) 12VDC MBA 128 1750080 .12A 90 77 10(250) 12VDC MBA 1210 1750060 .12A 92 78 6(150) 24VDC MBA246 1750100 .06A 87 77 8(200) 24VDC MBA248 1750110 .06A 91 79 10(250) 24VDC MBA2410 1750090 .06A 94 80 6(150) 24VAC PBA246 1806024* .I7A 91 78 8(200) 24VAC PBA248 1808024* .I7A 94 77 10(250) 24VAC PBA2410 1810024* .17A 94 78 6(150) 120VAC PBA1206 1806120* .05A 92 83 8(200) 120VAC PBA1208 1808120* .05A 99 84 10(250) 120VAC PBA12010 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. *Does not have ULC listing. In outdoor or wet installations,bell must be mounted with weatherproof backbox,BBK-1 or BBX-1.Standard electrical boxes will not provide a weatherproof enclosure.If the bell and/or assembly is exposed to moisture,it may fail or create an electrical hazard. Potter Electric Signal Company,LLC•2081 Craig Road,St.Louis,MO,63146-4161•Phone:800-325-3936/Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#5400776-REV Y PAGE 1 OF 2 5/08 P POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC Bells Dimensions Inches(mm) Wiring(rear view) Fig. 1 Fig.3 A.C.BELLS 10°[ 1) WHITE(INl WHITE(OUT) (250) 8 — 6. ( FROM CONTROL 1P111 (200) 6•. CEDINGPANEL B (150) I �7 PRECEDING BELL IBLACK(IN) _I- BLACK(OUT) CAUTION: WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. 2 11/16" (68) DW(I6 776-I NOTES: I.WHEN USING AC'BELLS,TERMINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL. 2 END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS. DWG4 776-1 Weatherproof Backbox Dimensions Inches(mm) Fig.2 FACP Box has one threaded 1/2"conduit entrance Ilk. _r1_ pi itillov 5 3/4" — JL To Next (146) (66) (I27) Device or End-of-Line L_ p Resistor w- ___ .....0.1 1 5/8" 186) (411 f- 4 1/4" (108) Installation DW(,6 776.2 I. The bell shall be installed in accordance with NFPA 13,72,or local AHJ.The top of the device shall be no less than 90"AFF and not less than 6"below the ceiling. 2. Remove the gong. 3. Connect wiring(see Fig.3). o / 4. Mount bell mechanism to backbox(bell mechanism must be Dmounted with the striker pointing down). 1110, 5. Reinstall the gong(be sure that the gong positioning pin,in the mechanism housing,is in the hole in the gong). 6. Test all bells for proper operation and observe that they can (, 5 BBX-1 i be heard where required(bells must be heard in all areas as designated by the authority having jurisdiction). Failure to install striker down will prevent bell from operating. IIYW' PRINTED IN USA MFG.#5400776-REV Y PAGE 2 OF 2 5/08 "BEP" 12V DC Data Sheet 7Ah Batteries NP SERIES - NP7-12 ,,„. Reliability is your Security Yuasa NP, NPC and NPH Batteries. Utilising the latest advance design Oxygen Recombination "" 1111111111111111111 `;2via� Technology, Yuasa have applied their 80 years 7.:71...L2 ----� e re9�deteaexperience in the lead acid battery field to producelir ed eea.��n�ar9eaPle petrery 9 the optimum design of Sealed Lead Acid batteries. yuASA — p lop'5 ., ,r FEATURESjT0 ._______:_----,ER,A uK YUA$`. ,1g� ypoEMu. • Superb recovery from deep discharge. r. . , • Electrolyte suspension system. • Gas Recombination. • Multipurpose:Float or Cyclic use. Terminals • Usable in any orientation(except continuous inverted). NP batteries are manufactured using a range of terminals • Superior energy density. which vary in size and type.Please refer to details as • Lead calcium grids for extended life. shown. • Manufactured World wide. Operation in any Orientation • Application specific designs. The combination of sealed construction and Yuasa's unique electrolyte suspension system allows operation in Technical Features any orientation,with no loss of performance or fear of electrolyte leakage. (Excluding continuous use inverted) Sealed Construction Yuasa's unique construction and sealing technique Valve Regulated Design ensures no electrolyte leakage from case or terminals The batteries are equipped with a simple,safe low pressure venting system which releases excess gas and Electrolyte Suspension System automatically reseals should there be a build up of gas ,,,,.,, All NP batteries utilize Yuasa's unique electrolyte within the battery due to severe overcharge. Note.On no suspension system incorporating a microfine glass mat to account should the battery be charged in a sealed retain the maximum amount of electrolyte in the cells.The container. electrolyte is retained in the separator material and there General is no free electrolyte to escape from the cells.No gels or other contaminants are added. Specifications 7 Control of Gas Generation Nominal Capacity(Ah) NP7.12 The design of Yuasa's NP batteries incorporates the very latest oxygen recombination technology to effectively Layout 20hr to 1.75vpc 30°C 7 control the generation of gas during normal use. 10hr to 1.75vpc 20°C 6.4 Low Maintenance Operation 4 O 5hr to 1.70vpc 20°C 5,9 Due to the perfectly sealed construction and the 1nr to 1.60vpc 20°C 4.2 recombination of gasses within the cell,the battery is O Voltage 12 almost maintenance free. Energy Density(wht2ohr) 91 Specific Energy(wh kgzonr) 32 Terminals I Int. Resistance(m.Ohms) 25 Maximum discharge(A) 1 40/75 Faston tab:187 A Faston tab:250 D Short Circuit current(A) 210 i85-004 70 JNCHH=MM 250 .004 020 INCH=MM Dimensions(mm) .250 6.35 I 1 .310 7.90 Length 1__51 059 .185 4.70 .250 6.35 —lc —; �� Width 65— .124 3.15 .16 4.0 .098 2.50 .031 0.8 Height overall 97.5 .059 1.50 —� .020 0.5 , r- .031 0.80 I Weight(Kg) 2.65 .020 0.50 ' Terminal A/D 'll fl« .004 0.10 031..aaa Layout 4 .031 W WWA yu s - a er o.uk rat, NP SERIES - NP7-12 Data Sheet Lead Calcium Grids Long shelf Life The heavy duty lead calcium alloy grids provide an extra The extremely low self discharge rate allows the battery to margin of performance and life in both cyclic and float be stored for extended periods up to one year at normal applications and give unparalleled recovery from deep ambient temperatures with no permanent loss of capacity. discharge. Operating Temperature Range Long Cycle Service Life The batteries can be used over a broad temperature range Depending upon the average depth of discharge,over a permitting considerable flexibility in system design and thousand discharge/charge cycles can be expected. location. Float Service Life Charge -15°C to 50°C The expected service life is five years in float standby Discharge -20°C to 60°C applications. Storage -20°C to 50°C(fully charged battery) Separators The use of the special separator material provides a very efficient insulation between plates preventing inter-plate SELF DISCHARGE CHARACTERISTICS short circuits and prohibiting the shedding of active materials. (501100 0°C t32°F) 75 CYCLIC RECHARGE REGIME G15G" Bulk Charge ��Standby Charge Z 20°C B"F) Z 0.3- 150 I I] _ Time=t 0` Time=1l2 . , 40°C(104°') 30°C(865F) -16 25 _0.25 - 125 -'"- Charge Volume z. 15 > 0.2 -6L 100- Z o Charge voltage -14 0 A 3 6 9 12 I5 18 9.16 75- 4STORAGE TIME(MONTHS) j +13 0.1 - 50- Current Trip Point -12 ?, G,t i-0.07C Amps 0.95 25- _It It FLOAT CHARGE CHARACTERISTICS .,Charge Current 0 - 0 ,0 C U' aw me �w < co w� ¢¢ C u> ...>Qm 0.25CA-2.275VPC CONSTANT VOLTAGE CHARGING ¢- (%) (4CA) (V) AT 20°C(68°F) rlo 140 - IV) NP DISCHARGE CHARACTERISTICS ,n 0.25 CURVES AT 25°C (77°F) 7.50- CHARGED VOLUM __-_ 15.0 100 0.20 - - (V) IV) Note.C-Given capacity as slated on each battery In Ah 7.00- FOR 12V FOR 6V CHARGE VOLTAGE 74.0 BATTERY BATTERY 80 NP AT 25°C(77°F) 0.15 I 13.0- 6.5-- 60 6.50-/1' AFTER 100%DISCHARGE 1J 0 12,0' 6.0 0.10 / ---AFTER 50%DISCHARGE 6.00-/ 1 120 f ° 0.05 FWD- 11.0- 5.5 20 1 5.50 I' • 11.0 JO J 'o cn o SCA 0 __ CHARGING CURRENT <10.0_ 5,0 i-- 92GA 0 0 2 4\ 6 B 10 12 '4 16 18 20 CHARGING TIME(MOURSI Fs ..� 8.0- 4 0 -- TYPICAL DISCHARGE CHARAC- TERISTICS NP RANGE - 1 2 4 6 810 20 40 60 2 4 6 010 20 MINUTES DISCHARGE TIME HOURS CYCLE SERVICE LIFE IN RELATION TO DEPTH OF DISCHARGE TESTING CONDITIONS:DISCHARGE CURRENT.0.17C Amp.(P.O 1.7V/CELL CHARGING CURRENT 0.09C Amp. CHARGING VOLUME:125%OF DISCHARGED CAPACITY < 'A"4' AMBIENT TEMPERATURE 20°C TO 25°C(68"F TO 77°F) FLOAT SERVICE LIFE NP RANGE l 4 \ -_TESTfKi CONDITIONSOM VOLTAGE ,7VPC(AH°) ABbrr TO18EATUrie.,C leflFTO7F b `0 .1_ en 100 Yam 0 O 80- ° DOD 100% O T, OF DISCHARGE b 49 20 -0 0 1 2 3 4 5 5.5 2rx, ma eao ace loon Ism 1w0 '4rj,/}+• LIFE(YEARS) NUMBER OF CYCLES r fPy�q g ./F//jig�.' !'t//�x)rygy± / p3 �w. p fj • r -f r ��r:r !, , W Si 6. N 1'hrfi w TtrtkF' s, 'kr�®!ry.,c;o.4d6 t. tn.t y;,f' , NP SERIES - NP7-12 Data Sheet INTELLIGENT BATTERY CHARGERS Manufactured to BS3456, IEC335,UL 1236, NPH DISCHARGE CHARACTERISTIC CURVES EN60335,CE mark to EN5008-1 (a, (V) FOR 12V FOR EL( BATTERY BATTERY Features 13-0- 6.5 Micro processor controlled 12.0- 5.0 . Short circuit protection a F11.0- 5.5---------------------,,...,._) Reverse polarity protection o High temperature protection > 10.0_ 5.0 0.ao ,'0.2CA a 0.4CA Soft start current control E 90_ 45- cAecA Fast constant current bulk charge W 3CA 3 stage charging CI-CV-float I- 80- 40 «A - Constant voltage float/standby 7.0_ 3.5 0.1 0.6 1 2 34 5610 20 304060 2 34 6810 Proportional timing MINUTES HOURS Flexibility,to match battery specification. DISCHARGE TIME Standard Range Standard NP YCP03Al2 300mA 12v Available in a wide range of sizes to suit general applications. YCP03A24 300mA 24v YCP03A6 300mA6v NPH/NPW YCP06Al2 600mA 12v High performance batteries specially designed for applications requiring YCP06A6 600mA 6v high rate discharge,supplying up to 50%(NPH),(NPW)more power YCP1.5Al2 1.5A 12v (Watts)for short durations when compared to conventional NP models. YCP1.5A24 1.5A 24v YCP1.5A6 1.5A 6v NPC YCP1 Al2 1 A 12v Specifically designed to suit the arduous requirements of cyclic YCP1 A6 1 A 6v applications allowing increased cycle life(at least double that of YCP2Al2 2A 12v conventional types).(NPC Shortform refers) YCP2A24 2A24v NPL YCP2A6 2A 6v Long Life Model also to BS629Opt4(FR Options) YCP3Al2 3A 12v Dedicated literature available on request.(NPL Shortform refers). YCP4Al2 4A 12v YCP6Al2 6A 12v Applications YCP8Al2 8A 12v Yuasa NP batteries,having excellent deep discharge recovery YCP10Al2 10A 12v characteristics coupled with long life on float standby,are ideal for YCP8A24 8A24v numerous applications in both cyclic and standby modes.For advice on the use of NP batteries in your particular application please contact RELATIONSHIP BETWEEN our Sales Office. CHARGING VOLTAGE AND TEMPERATURE Charging For Float Standby Applications Charged at 2.275 volts per cell continuous.The battery will seek its own k w current level and float fully charged. However,users should be aware - that when charging from fully discharged,the battery can draw an initial 5. z charge current of approximately 2cA.Care should therefore be taken to 15.6 7.6 2.6 -- ensure that this initial charge current(if ungoverned)is within the CYCLE ISE output capability of the equipment.Final charge current at 2.275 volts 15.0 7.5 25`4...-- per cell is typically between 0.0005cA to 0.004cA. 0III 2 14.4 7.2 2.4 Charging For Cyclic Applications See cyclic recharge regime graph. 3.6 6.9 2.,----. - CAUTION STAND-SY USE - Do not Short Circuit 13.2 6.6 2.2-- -"-"-- I r - Do not charge in a sealed container _,0 0 10 20 30 40 60 601C1 Service life and operational characteristics will 14 32 50 66 86 04 22 40;°F7 be affected by temperature AMBIENT TEMPERATURE - AC Ripple reduces service life. 1) Yua Batt Sales (UK) Ltd Distributed by Unit 22 Rassauery Industrial Estate sa Ebbw Vale,Gwent,NP23 5SD Tel:08708 500312 Fax:08708 500317 E-mail:enquiries@yuasa-sales.co.uk YUASARegistered number 1548820 Cat.No. NP7-12 February 07 E&O.E. "FACP" 12V DC 18Ah Batteries 4. gélesis/ i a. r,. t t,f�er rr 6 � � ,wi,j4,,J( f *If k„„-,10 r,..,,,..7.,-- ',.. ••.•r: ,47,„„;„,,,,„ ,,,,,, .„ _,,„„,„„ ; ,, ........ ,,, „tit ,/.4„a„,, , , „../.,,.„,„„.,, i.4„, 4„, ,.,,,,,„ ,/ ..., 1 i0„ 4lYt l t 14/, E; 41,7/1` NP 18- 12B r :,,, r i r �,e#i;r /rg 1,f /` ,i rra, N ' ° ' NP 1 B- 12Br1?7 Sealed Rechargeable Specifications Lea1d/Acid Battery •NOMINAL VOLTAGE: 12V •CHARGE RETENTION(shelf life) 12 V, 17.2A h at 68'F(20'C): •NOMINAL CAPACITY: 1 month 97% 20 hr.rate of 0.86A to 10.5V 17.2Ah 3 months 91% 10 hr.rate of 1.6Ato 10.5V 16.0Ah 6 months 85% Terminal 5 hr.rate of 2.9A to 10.2V 14.5Ah 1 hr.rate of 10.3A to 9.60V 10.3Ah •LIFE EXPECTANCY: STANDBY USE 3 to 5 years ply=OD4 •WEIGHT(approx.): 13.70 pounds CYCLE USE (approx.): 6T sea (6.2 kgs.) 100%depth of discharge 250 cycles 216 1 r 50%depth of discharge 550 cycles •ENERGY DENSITY(20 hr.rate): 30%depth of discharge 1200 cycles 1.47 WH/cubic inch(90 WH/liter) - •SEALED CONSTRUCTION: •SPECIFIC ENERGY(20 hr.rate): Can be operated in any position _ 15.1 WH/pound(33.28 WH/kg) without leakage. INCH = MM •INTERNAL RESISTANCE OF CHARGED •STANDARD TERMINAL: ` .427 12.00 BATTERY: Bolt fastened terminal �- 433—•� 453 11.50 11 milliohms(approx.) .433 11.00 •HOUSING MATERIAL: ABS Resin .216 5.50 •MAXIMUM DISCHARGE CURRENT .079 2.00 WITH STANDARD TERMINALS: •OPTIONAL: DIMENSIONS:INCHES 150 amperes Container and cover made from Flame Retardant ABS •MAXIMUM SHORT-DURATION (UL94-VO/L.O.I.>28%) DISCHARGE CURRENT: Dimensions 450 amperes •HARDWARE: 2-M5-.8 x 12mm Bolt w/nuts, � r= 1 •OPERATING TEMPERATURE RANGE: lock washer&flat washer CHARGE 5°F to 122°F L (-15°C to 50°C) o6.z.1 l I,_ __ DISCHARGE -4°F to 140°F I`r'1a04°s°z1 El 6 L ® ID565 (-20°C to 60°C) u+:+ r r1 :_� 3 gg Xi I . . DIMENSIONS:MM(INCHES) T'l la m RECOGNIZED BY UL,File No.MH 16464 ner ry „......00E Power/Full So/utions— Publication No:US-NP18-12B-01 •November 2002 z#, • DISCHARGE CHARACTERISTIC TEMPERATURE EFFECTS IN RELATION CURVES AT 25°C (77°F) TO BATTERY CAPACITY al m Ba:Iery BanelY Banery NP Temperature 25•C(T2•F) W ) 02 120 1 120• to-+0 ;�•��.•'`�-I„ c 100' pp5GA _�.11��1\�11r1 F. re.p SO—319Pow— .'1''„1„� T.2C '.iCA1.05C• a. C •,./' 0'2G CC e° +0-2 e2.,111 2Cp 11111111 44 s �_20 3GA ■■ ■, ■,1'■, I o_ 0 2 + e e m za +o e° 2 + e e is zp —20 --10 0 10 20 30 40 50 ("C) 1.- -T111 I rnee 44 -24 14 32 50 68 86 104 122 (°F) p�:cn Temperature SELF DISCHARGE CHARACTERISTICS OPEN CIRCUIT VOLTAGE VS REMAINING CAPACITY (%) i41Io AT 25°C(77°F) a 100 L. a t I _. 75 > 13.0 -----. 1- co z c2 zcc a 50 I __ '_ _____ _y u 120 20'C(68'F) z x 40'C(104T) 30'C(86'9 a- I I II i t l 0 6 9 12 15 18 10.0 I 1 0 20 40 60 80 100 STORAGE TIME(MONTHS) REMAINING CAPACITY(%) CYCLE SERVICE LIFE IN RELATION FLOAT SERVICE LIFE TO DEPTH OF DISCHARGE u TESTING CONDITIONS:DISCHARGE CURRENT:0.17C AMP.(F.V.1.7V/CELL) a CHARGING CURRENT:0.09C AMP. J TESTING CONDITIONS:FLOATING VOLTAGE 2.25 TO 2.30V/CELL CHARGING VOLUME:125%OF DISCHARGED CAPACITY a cc AMBIENT TEMPERATURE:20°C TO 22%(64'F TO 72.9 a (AH%) AMBIENT TEMPERATURE:20'C TO 25'C(6MF TO 77°F) a (pH%) L 120 120 i 100 IIS; La 40 100%D.O.D. 50%D.O.O. 30%DEPTH OF DISCHARGE 1- 20 w () 40 U ¢ 0 1 2 3 4 5 5.5 d e. 20 LIFE(YEARS) o 0 O 200 400 600 800 1000 1200 1400 N NUMBER OF CYCLES -oo E c, When the battery will be used by current in excess of 3C,consult with EnerSys, Inc.prior to use. Z • CHARGING METHODS(At 20°C) Cycle use: Maximum charging current 4.3A Charging voltage 14.4 to 15.0V CAUTION •Avoid short circuit Standby use: Float charging voltage 13.50 to 13.80V N •Do not charge in a sealed container. °p a Z L- b Z c 0 0 u a o EnerSys Inc. EnerSys EMEA P.O. Box 14145 Brussels, Belgium Represented by: Reading, PA 19612-4145 Tel:+32(0)2 247 94 47 941. .4........ USA EnerSys Asia Tel:+1-610-208-1991 Guandong, China +1-800-538-3627 Te1:+86 755 2689 3639 www.enersysinc.corn