Loading...
Report OFFICE COPY RECEIVED C CITY OF TIGARD BUILDING DIVISION WYAT T FIRE PROTECTION, INC. 9095 S.W. Burnham Tigard, OR 97223 WARBY PARKER WASH 90.40 -9460 SW WASHINGTON SQ RD TIGARD, OR 97223 PLEASE PROVIDE OFFICE COPY COMPLETED NFPA 13 f CITY OF TIGARD, MATERIAL AND TEST REVIEWER FOR CODE COMPLIANCE CERTIFICATE AT 'Approved: I FINAL INSPECTION OTC: I I Permit#: AQca) ^O(7 0 g l Address: c J O plc,‹ sr. Suite#: By: ) A - Date: c`ZI VALIDITY OF PERMIT THE ISSUANCE OF A PERMIT BASED ON CONSTRUCTION PROVIDE EITHER DOCUMENTS AND OTHER FLEXIBLE SPRINKLER DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM HEAD OR 2-INCH REQUIRING THE CORRECTION OVERSIZE RINGS OF ERRORS. OSSC 105.4 OR. INTERP 10-01 FIRE PROTECTION EQUIPMENT SUBMITTAL ti,coWorldwide, Contacts Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General NOTICE The TYCO Series TY-FRB Sprinklers Description described herein must be installed ii ' and maintained in compliance with •` The TYCO Series TY-FRB,5.6 K-factor, this document, as well as with the Upright (TY313) and Pendent (TY323) applicable standards of the National Sprinklers described in this data sheet Fire Protection Association,in addition l . are quick response,standard coverage, to the standards of any other authori- decorative 3 mm glass bulb-type spray ties having jurisdiction.Failure to do so sprinklers designed for use in light or may impair the performance of these ordinary hazard,commercial occupan- devices. cies such as banks,hotels, and shop The owner is responsible for main- - ping malls. taining their fire protection system The recessed version of the Series and devices in proper operating con- TY-FRB Pendent Sprinkler, where dition. Contact the installing contrac- applicable, is intended for use in areas tor or product manufacturer with any with a finished ceiling. This recessed questions. pendent sprinkler uses one of the . following: Sprinkler • A two-piece Style 15 Recessed Identification . Escutcheon with recessed adjust- #. ** ment up to 5/8 in. (15,9 mm) from ` the flush pendent position. Number (SIN) ? ` • A two-piece Style 20 Recessed TY313. . . . Upright 5.6K, 1/2 in NPT Escutcheon with recessed adjust- TY323. . . .Pendent 5.6K, 1/2 in. NPT Tr. ment up to 1/2 in. (12,7 mm) from the flush pendent position. Technical The adjustment provided by the Operation Recessed'Escutcheon reduces the Data accuracy to which the fixed pipe drops The glass bulb contains a fluid which to the sprinklers must be cut. Approvals expands when exposed to heat.When Refer to Table A the rated temperature is reached, the Intermediate level versions of Series fluid expands sufficiently to shatter the TY-FRB Sprinklers are described in Maximum Working Pressure glass bulb, allowing the sprinkler to Thchnical data'sheet TFP57. Sprin- 175 psi(12.1 bar) activate and water to flow. kler guards and shields are described 250 psi(17.2 bar)' in Technical Data Sheet TFP780. "The maximum working pressure of 250 psi(17.2 bar) Design only applies to the listing by Underwriters Laborato- ries,Inc.(UL). Discharge Coefficient Criteria IMPORTANT K=5.6 GPM/psi"(80,6 LPM/bar'/=) The TYCO Series TY-FRB,5.6 K-factor, Refer to Technical Data Sheet Temperature Rating Upright (TY313) and Pendent (TY323) TFP2300 for warnings pertaining to Refer to Table A Sprinklers are intended for fire protec- regulatory and health information. tiori systems designed in accordance Finishes with the standard installation rules Always refer to Technical Data Sprinkler:Refer to Table B Sheet TFP700 for the "INSTALLER recognized by the applicable Listing or WARNING" that provides cautions Recessed Escutcheon:White Coated, Approval agency (such as, UL Listing with respect to handling and instal- Black Coated,Chrome Plated,or Brass is based on the requirements of NFPA lation of sprinkler systems and coal- Plated 13, and FM Approval is based on the ponents. Improper handling and Physical Characteristics requirements of FM's Loss Prevention installation can permanently damage Frame Bronze Data Sheets).Only the Style 15 or Style a sprinkler system or its compo- Button Brass/Copper 20 Recessed Escutcheon is to be used nents and cause the sprinkler to fail Sealing Assembly...Stainless Steel w/TEFLON for recessed pendent installations. to operate in a fire situation or cause Bulb Glass . it to operate prematurely. Compression Screw Bronze Deflector Bronze Page 1 of 4 AUGUST 2018 TFP172 TFP172 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16" (11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* 0.1/Ins=I,%\N� / I 5 ��, 7/,6" �__ \ \ (11,1 mm) 1 '■ 4 NOMINAL 2" } I� 0 R MAKE IN (50,8 mm) ei- 2 D' is 2" \j (� 1 3/8" 3 ! �� (50,8 mm) (34,9 mm) I J 1 WRENCH , i ATS 1/2"NPT** DEFLECTOR* -� 2-7/8"(73,0 mm)DIA. - CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Installation Step 2. With pipe-thread sealant L� applied to the pipe threads, hand- The TYCO Series TY-FRB,5.6 K-factor, tighten the sprinkler into the sprinkler WRENCH RECESS Upright (TY313) and Pendent (TY323) fitting. (USE ONLY Sprinklers must be installed in accor- Step 3. Tighten the sprinkler into the ........ END"A") dance with this section, sprinkler fitting using only the W-Type '� General Instructions 6 Sprinkler Wrench(Figure 2).With ref- FIGURE 2 Do not install any bulb-type sprin- erence to Figure 1,apply the W-Type 6 W-TYPE 6 kler if the bulb is cracked or there is Sprinkler Wrench to the wrench flats. SPRINKLER WRENCH a loss of liquid from the bulb. With the Torque sprinklers 7 to 14 lb-ft (9,5 to sprinkler held horizontally, a small air 19,0 N•m). bubble should be present. The diam- Recessed Pendent Sprinklers WRENCH eter of the air bubble is approximately The Series TY-FRB Recessed Pendent RECESS 1/16 in.(1,6 mm)for the 135°F(57°C)and Sprinklers must betse installed in accor- 3/32 in. (2,4 mm)for the 286°F(141°C) dance with the following instructions. rij temperature ratings. Step A. After intalling the Style 15 A leak-tight 1/2 in. NPT sprinkler joint or Style 20 Mounting Plate over the should be obtained by applying a sprinkler threads,and with pipe thread II minimum to maximum torque of 7 to sealant applied o the pipe threads, ., 14 Ib ft(9,5 to 19,0 N m). Higher levels hand tighten th sprinkler into the `�, of torque can distort the sprinkler Inlet sprinkler fitting. with consequent leakage or impairment StepB. Tighten the sprinkler into the PUSH WRENCH of the sprinkler. sprinkler fitting using only the W-Type IN TO ENSURE Do not attempt to compensate for 7 Recessed Sprinkler Wrench (Figure ENGAGEMENT insufficient adjustment in the Escutch- 3).With reference to Figure 1,apply the WITH SPRINKLER eon Plate by under- or over-tightening W-Type 7 Recessed Sprinkler Wrench WRENCHING AREA the sprinkler. Re-adjust the position of to the sprinkler wrench flats. Torque FIGURE 3 the sprinkler fitting to suit. sprinklers 7 to 14 lb-ft(9,5 to 19,0 N•m). W-TYPE 7 RECESSED SPRINKLER WRENCH Upright and Pendent Sprinklers Step C. After ceiling installation and The Series TY-FRB Upright and finishing, slide on the Style 15 or Style Pendent Sprinklers must be installed 20 Closure over the Series TY-FRB in accordance with the following Sprinkler and push the Closure over the instructions. Mounting Plate until its flange comes in Step 1.Install Pendent sprinklers in the contact with the ceiling. pendent position. Install upright sprin- klers in the upright position. TFP172 Page 3 of 4 Care and _ 2-7/8" DIA. _ (73,0 mm) Maintenance 2-1/4" DIA. - The TYCO Series TY-FRB,5.6 K-factor, FACE OF (57,2 mm) Upright (TY313) and Pendent (TY323) SPRINKLER Sprinklers must be maintained and ser- FITTING 5/8"(15,9 mm) viced in accordance with this section. + \ - FLUSH Before closing a fire protection system 3/8±5/16" main control valve for maintenance (9,5±7,9 mm) A.21 '/ / + , work on the fire protection system / that it controls, obtain permission to , 1/8, shut down the affected fire protection MOUNTING systems from the proper authorities SURFACE _ (3,2 mm) and notify all personnel who may be CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) affected by this action. TY-FRB PLATE 3/4"(19,1 mm) Absence of the outer piece of an FIGURE 4 escutcheon,hole,w canh is usedelasprinklert cover SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) a clearance delay E 5/8 INCH TOTAL ADJUSTMENT STYLE 15 WITH TWO PIECE operation in a fire situation. RECESSED ESCUTCHEON The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only 2-7/8" DIA. _ cleaned by means of gently dusting (73,0 mm) with a feather duster; otherwise, non- FACE OF operation in the event of a fire or inad- SPRINKLER _ 2-1/4" DIA. vertent operation may result. FITTING (57,2 mm) Sprinklers which are found to be 5/16±1/4" leaking or exhibiting visible signs of (7,9±6,4 mm) 1/2"(12,7 mm) corrosion must be replaced. + - FLUSH Automatic sprinklers must never be = I ► ,7 i painted, plated, coated, or other- wise altered after leaving the factory. } / 0�� Modified sprinklers must be replaced. MOUNTING 1/8" Sprinklers that have been exposed to SURFACE (3,2 mm) corrosive products of combustion,but have not operated,should be replaced if they cannot be completely cleaned CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) by wiping the sprinkler with a cloth or TY-FRB PLATE 7/8"(22,2 mm) by brushing it with a soft bristle brush. FIGURE 5 Care must be exercised to avoid SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) damage to the sprinklers before, WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 during, and after installation. Sprin- RECESSED ESCUTCHEON klers damaged by dropping, striking, wrench twist/slippage,or the like,must Limited Recessed Escutcheon be replaced. Also, replace any sprin- Specify: Style 15 Recessed Escutch- kler that has a cracked bulb or that has warrant eon with(specify*)finish,P/N(specify*) lost liquid from its bulb. (Ref. Installa- Y Specify: Style 20 Recessed Escutch- tion Section.) For warranty terms and conditions,visit eon with(specify*)finish,P/N(specify*) The owner is responsible for the www.tyco-fire.com. *Refer to Technical Data Sheet TFP770 inspection,testing,and maintenance of their fire protection system and devices Ordering Sprinkler Wrench in compliance with this document, as Specify: W-Type 6 Sprinkler Wrench, well as with the applicable standards Procedure P/N 56-000-6-387 of the National Fire Protection Asso- Specify: W-Type 7 Sprinkler Wrench, ciation (e.g., NFPA 25), in addition to Contact your local distributor for avail- P/N 56-850-4-001 the standards of any other authorities ability.When placing an order,indicate having jurisdiction.Contact the install- the full product name and Part Number ing contractor or product manufacturer (p/N)_ with any questions. Sprinkler Assemblies with NPT Automatic sprinkler systems are rec- ommended to be inspected, tested, Thread ConnectionsST or and maintained by a qualified Inspec- Specify: Series TY-FRB Upright IN tion Service in accordance with local Pendent (specify)Quick Sprinkler,p SIN requirements and/or national codes. (specify), K=5.6, Response, q (specify) temperature rating, (specify) finish, P/N (specify,refer to Table A). TFP172 Page 4 of 4 SPRINKLER FINISH(See Note 7) K TYPE TEMPERATURE BULB LIQUID NATURAL CHROME POLYESTERc FACTOR COLOR BRASS PLATED 135°F(57°C) Orange UPRIGHT 155°F(68°C) Red (TY313) and 175°F(79°C) Yellow 1,2,3,4,5,6 PENDENT(TY323) 200°F(93°C) Green 5.6 286°F(141°C) Blue 1/2 in.NPT 135°F(57°C) Orange PENDENT 155°F(68°C) Red (TY323) 175°F(79°C) Yellow 1,2,3,4 Figures 4a and 5b 200°F(93°C) Green Notes: 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. VdS Approved(For details,contact Johnson Controls,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-54-428-3377.) 6. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06)as Quick Response Sprinklers. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. a. Installed with Style 15(1/2 in.NPT)5/8 in.Total Adjustment Recessed Escutcheon,as applicable. b. Installed with Style 20(1/2 in.NPT)1/2 in.Total Adjustment Recessed Escutcheon,as applicable. c. Frame and Deflector only.Listings and approvals apply to color(Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS P/N a 7 7 — XXX — X — XXX SIN SPRINKLER TEMPERATURE FINISH RATINGS 370 5.6K UPRIGHT(1/2 in.NPT) TY313 1 NATURAL BRASS 135 135°F(57°C) 371 5.6K PENDENT(1/2 in.NPT) TY323 3 PURE WHITE(RAL9010)a 155 155°F(68°C) POLYESTER Notes: SIGNAL WHITE(RAL9003) a. Use suffix"I"for ISO 7-1 connection;for example, 4 POLYESTER 175 175°F(79°C) 77-370-4-175-I 5 JET BLACK(RAL9005) 200 200°F(93°C) POLYESTER 9 CHROME PLATED 286 286°F(141°C) Notes: a. Eastern Hemisphere sales only TABLE B SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 ^ 0)(002018 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. Joh/�so,1 NATIONAL FIRE PROTECTION ASSOCIATION and NFPA am registered trademarks of National Fire Protection Association-, Controls TEFLON Is a registered trademark of DuPont 1,l.1 mow : Eddythread 40 A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1.0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: • Has a Corrosion Resistance Ratio of 1.0 • Has a Pressure Rating of 300 psi • Is Lighter Weight Than Schedule 40 • Is Approved by Factory Mutual and Listed by Underwriters Laboratories • Is Produced in Accordance to ASTM A-135 and A-795 • Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves • Is Produced From Steel With Excellent Properties of Strength and Threadability • Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems` • Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS 1 1.461 1.083 70 1 1/4 2.070 1.418 51 1 1/2 2.547 1.654 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS 1 1.00 1.00 1 1/4 1.00 1.00 1 1/2 1.00 1.00 2 1.00 1.00 Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems n, 1819 Clarkson Road For additional information, UL us ( v�sL1 Chesterfield,MO 63017 contact your salesperson today at C `M� j BULL.MOOSE TUBE COMPANY (800)325-4467 (800)325-4467 or(636)537-2600 LISTED (� V FAX:(636)537-2645 in the USA, or from Canada www.bullmoosetube.com call(800)882-4666 41:> A CDED company e-mail:sales 2 bullmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 Ductile Iron Threaded Fittings rn ..74`` 'C'1441"er,4 ,'414 4,th „Alth.)di'61 1,11000,1444, tiny Iffi"F 424.t,it '1:1;AA'Phrfif. " tia4 44 3, 441 ?'11 'ff4 +,7 :11 /fir 1,1 al' 4 ,4 j 11:4t4f:/9).4 -P4? 4'74 4$71 ilAP" v 4/4 SMITHCOOPER® INTERNATIONAL Ductile Iron Threaded Fittings Specifications ' • branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 WSP Ductile iron castings conform to ASTM A536 C (1;11) US LISTED • Fitting dimensions conform to ASME B16.3 • Bushings and plugs conform to ASME B16.14 41>P • Fittings are 100% air tested APPROVED • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical&physical properties • Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Working Pressure, Nonshock psiG Degrees F 300# Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 � x- Ductile Iron Fittings- Class 300 UL/FM S` ' , ;; C ® tiS 414> APPROVED Fig. 35E 3- 90°Elbow LISTED filli , A , Size Part Number A Packing Weight in in Inner Master lb 1/7 35L 3001 1.13 100 200 0.2 3/4 35E 3006 1.31 70 140 0.3 A 1 35E 3010 1.50 40 80 0.5 j��; 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35L 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35L 3024 2.70 4 8 3.2 Fig. 35RE3- 90°Reducing Elbow B Size A B PackingWeight < > Part Number in in in Inner Master Ib irl3/4 x 1/2 358E3006004 1.20 1.22 80 160 03 lik ^• 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 1 x 3/4 35RE3010006 1.38 1.45 50 100 0 4 i�i i \II A 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4 x3/4 358E3012006 1,45 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1 52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1,80 20 40 0-8 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 358F3020004 1.60 1 97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 3511E3020010 1.73 2,02 16 32 12 2 x 1-1/4 35RE3020012 1.90 2.10 12 24 1.3 0, 2 x 1-1/2 3513E3020014 2.02 2.16 10 20 1.5 U 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 li C 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 T Fig. 35F 3-45°Elbow L. Size Part Number Weight PackingWei ht in in Inner Master lb _ yit 1/2 351 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 160 0.3 111111 1 35F 3010 1.13 40 80 05 1-1/4 35F3012 1.29 25 50 0.7 -1/2 35F 3014 1 44 20 40 1.0 ��� �A 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size A Packing Weight Part Number in in Inner Master lb 11111111 1/2 351 3004 1.13 80 160 0.3 •Vip4. Noe IA 3/4 35T 3006 1.31 30 60 0.5 I1 11 351 3010 150 25 50 0.7 ;, ,n.,....,.....qf 1-1/4 35T 3012 1.75 10 20 1.1 4 A )14 A ) 1-1/2 351 3014 1,94 10 70 1.5 2 35T 3020 2.25 6 12 2.4 2-1/2 351 3024 2.70 1 8 4.3 • 111 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com i 7 * ; t. Ductile Iron Fittings- Class 300 UL/FM :7 c (DI uS APPROVED Fig. 35RT3-Reducing Tee LISTED Size Part Number A B C Packing Weight jin in i2 i2 Inner Master lb � ; C 3 4 x 1/2 35813006004 1.20 1.20 1 22 60 120 0.4 1 x 1/2 35RT3010004 1.26 1.26 1.36 30 60 0.6 1 1 x 1/2 x 1 35RT3010004010 1.50 1.36 1.50 30 60 0-6 a ---_,.,_______ ,.., „, 1 x 3/4 35RT3010006 1.38 1.38 1.45 25 50 0.6 F t 1 x 3/4 x 3/4 35RT3010006006 1.38 1.31 1.45 35 70 0.6 B A 1 x 3/4 x 1 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1-1/4 x 1/2 351113012004 1,34 1.34 1.53 20 40 0.8 1-1/4 x 1/2 x 1-1/4 35RT3012004012 1.75 1.53 1.75 25 50 0.9 1-1/4 x 3/4 35E313012006 1-45 1.45 1.62 15 30 0.9 1-1/4 x 3/4 x 1-1/4 35RT3012006012 1.75 1.62 1.75 20 40 1.0 1 1/4 x 1 35813012010 1,58 1,58 1.67 15 30 1,0 1-1/4 x 1 x 1/2 35RT3012010004 1.34 1.26 1.53 25 50 0.7 1-1/4 x 1 x 3/4 351-313012010006 1 45 1.38 1.63 20 40 0.8 1-1/4 x 1 x 1 35RT3012010010 1.58 1.50 1.69 20 40 0.9 1 1/4 x 1 x 1-1/4 351313012010012 1.75 1.69 1.75 15 30 1.0 1-1/2 x 1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 1-1/2 x 1/2 x 1 1/4 35R73014004012 1.81 1.56 1.88 24 48 1.1 1-1/2 x 1/2 x 1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 1 1/2 x 3/4 358 13011006 1.52 1.52 1.75 16 32 1 1 1-1/2 x 3/4 x 1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 1.1 1-1/2x3/4x 1-1/2 35R13014006014 1-94 1.75 1,94 18 36 1.2 1-1/2 x 1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1 1/2 x 1 x 1/2 35813014010004 1.44 1.25 1.69 20 40 0.8 1-1/2 x 1 x 3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1-1/2 x 1 x 1 351313014010010 1.65 1.50 1.80 16 32 1.0 1-1/2 x 1 x 1-1/4 35RT3014010012 1.82 1.67 1.88 12 24 1.2 1-1/2x 1 x 1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1 3 1-1/2 x 1-1/4 35RT3014012 1.82 1.82 1.88 12 24 1.4 1-1/2 x 1-1/4 x 1/2 35R13014012004 1.41 1.34 1.66 16 32 0 9 1-1/2 x 1-1/4 x 3/4 35RT3014012006 1.52 1.45 1.75 16 32 1.0 1-1/2 x 1-1/4 x 1 351313014012010 1 65 1.58 1.80 16 32 1.1 1-1/2 x 1-1/4 x 1-1/4 35RT3014012012 1.82 1.75 1.88 14 28 1.3 1-1/2 x 1-1/4 x 1-1/2 35813014012014 1.94 1.88 1.94 14 28 1 4 2 x 1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 2 x 3/4 35R13020006 1.60 1.60 1.97 10 20 1 6 2 x 1 35RT3020010 1.73 1.73 2.02 8 16 1.7 2 x 1 x 2 35813020010020 2,25 2.02 2.25 8 16 1.9 2 x 1-1/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 2 x 1-1/4 x 2 351-313020012020 2.25 2.10 2.25 8 16 2.0 2 x 1-1/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 2 x 1-1/2 x 1/2 358T3020014004 1.49 1.41 1.88 10 20 1.3 2 x 1-1/2 x 3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2 x 1-1/2 x 1 35813020014010 1.73 1.65 ?02 8 16 1.5 2 x 1-1/2 x 1-1/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2x 1-1/2 x 1-1/2 35R43020014014 2.02 1.94 2.16 8 16 1.8 Fig. 35RT3-Bull Head Tee Size A B C Packing Weight IINI H Part Number ts lc MI in in in in Inner Master lb x 1 358 13006010 1.45 1.45 1.37 30 60 . �� 1 x 1-1/4 35BT3010012 1.67 1.67 1.58 20 40 0.9 �� � 3/4 x 1-1/7 35B13010014 80 1.80 65 0 6 15 30 1.0 A-►< B > 1-1/4 x 1 x 1-1/2 35B13012010014 1.88 1.80 1.82 15 30 1.2 1-114 x 1-1/2 35E313012014 1.88 1.88 1 1.82 15 30 1.3 1-1/4 x 2 35BT3012020 2.10 2.10 1.90 10 20 1.6 1-1/2 x 1-1/4 x 2 358[3014012020 2.16 2.10 202 10 20 1 8 1-1/2 x 2 35BT3014020 2.16 2.16 2.02 8 16 1.8 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com 112 - Ductile Iron Fittings- Class 300 UL/FM 1 iris- c ® us 41> APPROVED A Fig. 35CP3 -Straight Coupling with Ribs LISTED IPSize Part Number A Packing Weight in in Inner Master lb _ 1/� 35C83004 1.38 200 100 0.1 3/4 35C83006 1.63 100 200 0.2 Nil '•' °� 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 219 25 50 0,7 2 35CP3020 2.62 15 30 1.2 ?-1i2 35C83024 3,00 9 18 2.2 Fig. 35RC3 -Hex Reducing Coupling Size Part Number1 lli ilko‘ A Packing Weight in in Inner Master lb A 1 x 1/2 358C3010004 69 80 160 0.3 1 x 3/4 35RC3010006 1.69 60 120 0.4 _;_�,� 1-1/4 x 3/4 359C3012006 2.06 40 80 0.6 2 x 1 (not hex) 35RC3020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing Size Part Number A Packing Weight B in in Inner Master lb 1 x 1/2 35H83010004 1.06 180 360 0 2 A 1 x 3/4 35HB3010006 1.06 180 360 0.1 1-1/4 x 1 35HB3012010 1.19 90 180 0.2 i i il l 1-1/2 x 1 35HB3014010 1.25 75 150 0.4 1-1/2 x 1-1/4 35HB3014012 1,25 75 150 0-3 $ 2 x 1 35HB3020010 1.38 40 80 0.6 2 x 1-1/4 35HB3020012 1.38 40 80 0 6 2 x 1-1/2 35HB3020014 1.38 40 80 0.6 Fig. 35SP3 -Square Head Plug Size A Packing Weight E in Part Number in94 Master Ib 1/2 . 600 700 iirrita 1 3/4 Inner 35SP300635SP3004 1.12 350 700 0.1 IA 35583010 0 125 200 1 100 0.07 1 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 - Fig. 35U 3- Union with Brass Seat A Size A Packing Weight , Part Number 1!" in in Inner Master lb supi°k® 1 35U 3010 2 19 20 40 1 0 1-1/4 35U 3012 2.50 15 30 1.2 111I 2 35U 3014 2.62 10 30 1.7 `_=�� 2 35U 3020 3.12 6 12 2.4 113 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com +dfld....nh}1.....,,.......EtldatAhWV4#+i.4..dt....M.I eN%*tie hrtu...... e°ldMu6itNataMH... NiMStsn..et..wh ar,"„ltrTr .. .„„.. „... R.. :+ '` :, , l ucti a ron fittings- ass I I I T ,: c ® us APPROVED A Fig. 35X 3— Cross LISTED t '1t A ' Size A Packing Weight - 1 inPart Number In Inner Master lb __ i, \,_ JA 1 35X 3010 1.50 20 40 0.9 ' 1-1/4 35X 3012 1.75 12 24 1.4 I I IA 1- 35X3014 194 8 16 18 2 35X 3020 2.25 6 12 2.8 B 13 Fig. 35RX3—Reducing Cross ` '` ' Size A B Packing Weight tamp A in Part Number in in Inner Master lb 1-1/2 x 1 358X3012010 1.67 1.58 15 301 24 2 ' J. 1-1/2 x 1 35RX3014010 1.80 1.65 12 1.4 mi MI I IA 2 x 1 35RX3020010 2,02 1.73 8 16 2.0 i rm Fig. 35C 3— Cap Size Part Number A Packing Weight S, in in Inner Master lb _ A 1/2 35C 3004 0.87 300 600 0.1 I I I 3/4 35C 3006 0.97 200 400 0.1 �I�� 35C 3010 6 110 220 0,2 1-1/4 35C 3012 1.28 70 140 0.4 1-1/2 35C 3014 1.33 50 100 0.5 2 35C 3020 1.45 25 50 0.8 2-1/2 35C 3024 1.70 18 36 1 6 Y Fig. 35BC3—Beam Clamp Size A Packing Weight Part Number AI in in Inner Master lb 3(8 35BC3003 0.75 00 200 0.3 1/2 35BC3004 0.75 80 160 0.5 1 SMITH-COOPER INTERNATIONAL° • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com 114 IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T 11STED us ® VdS 9PCB1 �. SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating 1/2,3/4,and 1'/15,20 and 25mm outlets for directly connecting sprinklers,drop nipples,sprigs,gauges,drains and other outlet products.Available for 11/4 through 76.1 mm/32 to 76.1 mm piping systems,Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe.When tightened,the assembly compresses the gasket onto the OD of the pipe.The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard,lightwall,Schedule 5 and other specialty pipes." Contact Victaulic for other optional coatings. "Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. Gasket: • Grade"E"EPDM-Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc.and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services up to the rated working pressure using the Grade"E"Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: • Orange enamel(North America, Latin America,Asia Pacific) • Red enamel(Europe) f£}Sf£}WNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victautic.com uSi fc a fl^+ SAS Si SC SS A RfCSSTFRFSl TRASSFMARK CIF VICTAI II IC CnMPANY C WENVICTAI II IC COMPANY Al I RIGHTS RFSFRVFI IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock° Outlet-T STYLE 922 DIMENSIONS Nominal Size Hole Approx. inches/mm Diameter Dimensions-inches/millimeters Weight Each Run X Branch +0.06/+2.5 Y Z FPTt 0,00/-0.0 T* V W Y Z lbs/kg 1 Ya Yz 1 3/16 1.30 1.83 1.10 3.87 2.56 1.0 1 32 X 15 30.2 33.0 46.5 27.9 98.3 65.0 0.45 V ��^��� T 4 1 3/16 1.28 1.83 1.10 3.87 2.56 1.1 I . 4 t 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 \�, ,:nW 1i1 1 13/16 152 2.18 1.10 3.87 2.56 1.2 IVI 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 1/ Yz 1 3/16 1.42 1.95 1.22 4.08 2.56 1.2 40 X 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 3/4 i 13/16 1.40 1.95 1.22 4.08 2.56 1.2 20 1 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 ! 13/16 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 65.0 0.59 2 1 13/16 1.66 2.19 1.46 4.60 2.56 1.3 50 X 15 ! 30.2 42.2 55.6 37.1 116.8 65.0 0.59 3/47 13/16 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 1 13/16 1.88 2.54 1.46 4.60 2.56 1.5 25 i 30.2 47.8 64.5 37.1 116.8 65.0 0.68 2/ Yz 1 13/16 1.91 2.44 1.71 5.40 2.55 1.6 65 X 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 3/4 , 13/16 1.89 2.44 1.71 5.40 2.56 1.6 20 j 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 I 13/16 2.13 2.79 1.71 5.40 2.56 1.6 25 i 33.2 54.1 70.9 43.4 137.2 65.0 0.73 76.1 mm X 1/2 f 1 3/16 1.91 2.44 1.71 5.50 2.56 1.6 15 1 33.2 48.5 62.0 43.4 139.7 65.0 0.73 3/4 1 13/16 1.89 2.44 1.71 5.50 2.56 1.6 ' 20 , 30.2 48.0 62.0 43.4 139.7 65.0 0.73 1 1 13/16 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT(optional) male pipe threads only.Use of male threaded products with special features,such as probes,dry pen- dent sprinklers,etc.,should be verified as suitable for use with this Victaulic product.Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads(dimensions are approximate). www.victaulic.com iC 4 y li VICTAI II IC IS A RFGtSTFRFn TRADEMARK OF VICTAIILIC COMPANY©2009 VICTA(11 IC COMPANY All RIGHTS RESERVED. au �cm IPS CARBON STEEL PIPE- HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T STYLE 922 • PERFORMANCE Equivalent Length of 1 inch Schedule 40 Steel Pipe(per UL Ron Size x Outlet Size 213,Section 16)(C=120)',FT Inches/rum Feet/meters 11 X 1 I 8.5 32 25 2.6 1 Y2 1 8.5 40 X 25 ? 2.6 50 X 25 2.6 2Y X 1 8.5 65 25 2.6 76.1 mm X 1 ; 8.5 25 2.6 *Hazen-Williams coefficient of friction is 120 www.victaulic.com tonal a it is n arrlcrFRrn TG0nFM0RK nr onrTAuI If'rnnAPO V 9nn0 vi(1Ai n it rI cr ooN Al I uicu I c uuc,uvr n ICt'aukc IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 1 O.52 FireLock° Outlet-T STYLE 922 INSTALLATION Reference should always be made to the I-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 •ctaul,C vlrrei a it ice DFrIQTFDFn TOAnCIOADV nF virrei II Ir rfMAPtNV 9(YQ virrei II Ir enMPANV AI I RII I-ITS PFSFRVFfI Pipe Hangers Fig. 200- "Trimline" Adjustable Band Hanger (B-Line Fig.B317ONF) ®TOLCO Fig. 200F- "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig.B317ONFF) COus Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) LISTED Fig.200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" 115mm)thru 8" 1200mm)pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and othergeneral piping p p p g purposes. Knurled swivel nut design permits hanger adjustment after installation. T Features: U ® • (1/2" (15mm)thru 2" (50mm)) Flared edges ease installation for all pipe ir types and protect CPVC plastic pipe from abrasion. Captured design 1 keeps adjusting nut from separating with hanger. Hanger is easily a B installed around pipe. A , For hanger with non-captured nut order Fig. 200S. ;, • (21/2" (65mm)thru 8" (200mm)) Spring tension on nut holds it securely in _ hanger before installation.Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm)thru 8" (200mm)) = Fig.200-1/z.200-3/4 in the USA(UL) and Canada (cUL)for steel and CPVC plastic pipe and Factory Mutual Engineering Approved(FM) (3/4" (20mm)thru 8" (200mm))• Fig.20a1to200-2 Fig.200-21/zto200-8 Conforms to Federal Specifications VVW-H-171 E&A-A-1192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, Type 10. Maximum Temperature: 650°F(343°C) Si.: Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts • ,. in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of o) FM DS 2-0. COC kill. 410006 13. Tv Fig. Fig.200C Fig.200F -Pipe Size Rod Size A B Approx.Wt./100 Part No. in. bum) in. (mm) in. Imm) lbs. (kg) -4.-- 200-1/2 1/2" (15) 3/8"-16 31/8" (79.4) 25/8" (66.7) 11 (5.0) 200-3/4 3/4" (20) 3/8"-16 31/8" (79.4) 21/2" 163.5) 11 15.0) 200-1 1" (25) 3/8"-16 33/8" (85.7) 25/8" 166.7) 12 (5.5) 200-11/4 11/4" 132) 3/8"-16 33/4" (94.0) 27/8" (73.0) 13 (5.9) 200-11/2 11/2" (40) 3/8"-16 37/8" (98.4) 27/8" (73.0) 14 (6.4) 200-2 2" (50) 3/8"-16 41/2" 1114.3) 3" (76.3) 15 (6.9) 44 200-21/2 21/2" (65) 3/8%16 55/8" (142.9) 41/8" (104.71 27 (12.3) 200-3 3" (75) 3/8'-16 57/8" (149.1) 4" 1101.6) 29 (13.3) Fig.200S 200-31/2 31/2" (90) 3/8"-16 73/8" 1187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) 3/8"-16 73/8" (187.3) 5" (127.0) 35 (16.0) 200-5 5" (125) 1/2'.13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2"-13 101/8" (257.2) 63/4" 1171.4) 73 (33.4) 200-8 8" (200) 1/2"-13 131/8" (333.4) 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line ° Fire Protection Solutions 21 by .` •111 r4:Piiii Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig.103) B3205L - Threaded Rod (right& left hand threads) Specify Length Ti. �lll. Size Range. 3/8"-16 thru 3"-4 rod L•�1ll4 01 Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. TLRod is threaded on A availableboth shown. with left and right hand threads-specify Fig. B3205L when �l ordering. 1h1111 Thread Size Maximum Temperature: 750°F(399°C) Finish: Plain.Contact B-Line for alternative finishes and materials. Order By: Part number, rod size, length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-3/8 x'L' 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) 03205-1/2 x'L' 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) B3205-5/8 x'L' 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) B3205-3/4 x'L' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) 133205-7/8 x'L' 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) B3205-1 x'L' 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55) B3205-11/8 x'L' 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93) 83205-11/4 x'L' 11/4%7 5" (127.0) 9500 (42.25) 7440 (33.09) B3205-11/2 x'L' 11/2"-6 6" (152.4) 13800 (61.38) 10807 (48.07) B3205-13/4 x'L' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) B3205-2 x'L' 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) 03205-21/4 x'L' 21/4"-41/2 9" (228.6) 32300 (143.67) 25295 (112.51) 03205-21/2 x'L' 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138,64) B3205-23/4 x'L' 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) 83205-3 x'L' 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR - All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig.100) Fig. 99 - All Threaded Rod Cut To Length ��\\`\� i11�11111111111111* Size Range: 3/8"-16 thru 11/2"-6 rod in 120"(3.05m)lengths or cut to length �..Y.' 1 111� Material: Steel f---" ,- , H 1:1d Maximum Temperature: 750°F(399°C) w `o Finish: Plain. Contact B-Line for alternative finishes and materials. c d t U Order By: Part number, rod diameter and finish a Part No.-Size x Length Threads Recommended Load Approx.Wt./100 Ft. ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) ATR 1/4"x 120 99-1/4"x length 20 240 (1.07) 12 (5.44) ATR 3/e"x 120 99-3/8"x length 16 730 (3.24) 29 (13.15) ATR 1/z"x 120 99-1/z"x length 13 1350 (6.00) 53 (24.04) ATR 5/8"x 120 99-5/a"x length 11 2160 (9.60) 89 (40.37) ATR 3/4"x 120 99-3/4"x length 10 3230 (14.37) 123 (55.79) ATR 7/8"x 120 99-7/8"x length 9 4480 (19.93) 170 (77.11) ATR 1"x 120 99-1"x length 8 5900 (26.24) 225 (102.06) ' All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Pipe Hangers&Supports 236 Revised 4/28/2014 by FA•N by VERTICAL MOUNT SAMMYS :,/.' ' -/'. SAMMYS° for Wood s : c Not less than ` r 2"nominal width Wood Flooring Product Features (1-1/2") s �► 4 •No pre-drilling required. Not less than •Quick to install using the Sammy I 3"nominal Nut Driver with an 18V cordless thickness(2-1/2") (depth or side Wood Joist drill/driver. e. r of vertical member) ...-- ' •Saves time from traditional • Double Sheetrock 1 methodsler . l tFor vertical use- Ceiling i! install in center of lower face. 1 •Reduces installation cost. Minimum 2"embedment into base material for NFPA t3 compliance. Composite/Truss •Made in the U.S.A. Vet Consult truss manufacturer for . ? recommended installation point. r = *Pre-drilling maybe required for GST f• '.. 25-380.Tool available on page 10.a reigi Agfo Approvals Rod Part Model Screw Ultimate UL Test FM Test Box Case - Size Number Descriptions Pullout(Ibs) Load fibs) Load(Ibs) Qty Qty — r',At210(7/16"OSB) 1/4" 8002957 GST 100 1/4 x 1" 25 125 670(3/4"Ply) -f 1/4" 8003957 GST 200 1/4 x 2" 1760 (Fir) 25 125 1/4" 8004957 GST 300 1/4 x 3" 2060(Fir) 25 125 3/8" 8006957 GST 75 1/4 x 3/4" 564 (3/4"Ply) 25 125 `v 3/8" 8007957 GST 10 1/4 x 1" 210(7/16"OSB) 300 25 125 azi oN4670(3/4"Ply) _ Q-Q 3/8" 8008957 GST 20 1/4 x 2" 1760 (Fir) 850 1475 25 125 viirier 3/8" 8068925 GST 20-SS 1/4 x 2" 1760(Fir) 850 25 125 °.` 3/8" 8009925 GST 25-380 3/8 x 2-1/2" 2113 (Fir) 1500 25 125 al Q 3/8" 8010957 GST 30 1/4 x 3" 2060(Fir) 1500 1475 25 125 #14 Black Nut Driver 3/8" 8069925 GST 30-SS 1/4 x 3" 2060 (Fir) 25 125 Part#8113910 3/8" 8011925 GST 40 1/4 x 4" 2180(Fir) 25 125 3/8" 8012925 GST 60 1/4 x 6" 2230 (Fir) 25 125 1/2" 8013925 GST 2 1/4 x 2" 1760(Fir) 25 125 1/2" 8014925 GST 2.5-380 3/8 x 2-1/2" 2113 (Fir) 25 125 1/2" 8015925 GST 3 1/4 x 3" 2275(Fir) 25 125 —1/2" 8016925 GST 4 1/4 x 4" 2180 (Fir) 25 125 ON 1/2" 8017925 GST 6 1/4 x 6" 2230(Fir) 25 125 _ #14 SW Red Nut Driver Part#8114910 A SAMMY Swivel Head° for Wood Product Features •Eliminates distortion of threaded rod. •Saves time from traditional methods. •Accommodates up to 3''/z"x 12 pitch roof. •Reduces installation cost. r •Allows 17°deflection from vertical. •Made in the U.S.A. 57/4414 Rod Part Screw Ultimate UL Test FM Test Min Box Case r. . Approvals Model r Size Number Descriptions Pullout(Ibs) Load fibs) Load(Ibs) Thickness Qty Coy 0 4 3/8" 8139957 SH-GST 20 1/4 x 2" 1257(Fir) 1050 1475 25 125 125 #0), Q..- 3/8" 8141957 SH-GST 30 1/4 x 3" 1720(Fir) 1500 1475 25 125 #14 Black Nut Driver gall SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into Part#8113910 contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. ' For the most up to date information,visit www.sammysuperscrew.com 4 I. III ____f' t 4 0 I II I 4 s i Iloilo,. RECEIVED • JUL 23707 CITY OF TIGARD SAMMY SIDEWINDER (GST IA BUILDING DIVISION ALL THREAD ROI (-,4*k ADJUSTABLE RING HANGER EYE GLASS RETAILER - A\GEC DETAIL SPACE L_ 1GiCF 2. NOT TO SCALE ',Annoy. I) / / i tE (• ti �7' ,:r _IS iii---,,_^;• it — _. .... f P, ttl �_ r_ y t IL �z ,_0 ` ( , ,, .0 . I �j 1 , ' i` ..: ,I ., S l , i -. E dl I ls - ` r - - 13+ I I : t , ' , $ r 7 , 1: I r e r 4 • -jI , , -rr 1 X F3 z �. I r— • „ __ 1 1 11 { tom. DEFLECTED CE LAG PLA\ <EY PLA\ 1/ 0" © NOT TO SCALE 0' 8' 16' NOTES REVISIONS SPRINKLER SYMBOLS Meets design requirements of NFPA 13 2016 edition. DATE DESCRIPTION BY SYIA�a STATUS BRAND ON TYPE RASH MET)ORIFICE THREAD<-FACTOWOTY __ FP-1 All piping to be Eddy Thread w/ screwed ductile iron fittings. NEW TYCO TY351 sSP-ORxn 155 1/2' 1/2' 5.620 ? ., q WARBY PARKER W YAT T •(�rr nn PERMIT NO. All hangers to be per NFPA 13 requirements. J�UV SW WASHINGTON SQ CONTRACT NO. C21-407 All armovers greater than 2'-0" shall be provided with hangers. FIRE PROTECTION,0 T EC T I O N, INC. DRAWN BY R.CAMPBELL [___. All of work area will be ordinary hazard occupancy. SCALE t/B's t'-o` Max. sprinkler spacing to be 130 sq. ft. per head. 9095S.W.Burnham TIGARD, OR 97233 All heads cut in from branch lines. Tigard,OR 97223 DATE /e,wN 2021 • (503)684-2928 REVISED HORIZON RETAIL CONSTRUCTION,1500 HORIZON OR STURTEVANT,VA 53177 1 OF 1