Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
/15105 f/1CIP/0 /114/Y / °3262/-OOd6S ..•.., COSCO Fire Protection RECEIVED t,i 11011 Mitt t., mi,.i .speti ili i,OFFICE COPY , a KIJ.�S r, . CITY OF TIGARD BUILDING DIVISION Fire Protection Material Fred Meyer 385 Click-List Expansion Tigard, Oregon COSCO Fire Protection Inc. Job # 24PS7847 2501 SE Columbia Way, Suite 100 Vancouver,WA 98661 Phone:360-883-6383 Fax: 360-883-6390 Toll Free:800-983-6383 .. ..... COSCO Fire Protection Fire Protection and life Safely Spc'cicctist.s • rinklers COSCO Fire Protection Inc. 2501 SE Columbia Way, Suite 100 Vancouver,WA 98661 Phone:360-883-6383 Fax: 360-883-6390 Toll Free:800-983-6383 Page 1 of 4 NIRKING VK1001 STANDARD TECHNICAL DATA RESPONSE UPRIGHT SPRINKLER (K5.6) The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. DESCRIPTION The Viking VK1001 Standard Response Upright Sprinkler is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT)coatings can be used in decorative applications where colors are desired. � � tMll3 In addition, these coatings have been investigated for installation in corrosive environments and are Listed and Approved as indicated in the Approval Chart. ., 2. LISTINGS AND APPROVALS C ® US UL Listed: Category VNIV ® FM Approved: Classes 2016, 2043 Approved for use in FM Approved vacuum dry sprinkler systems ,, APPROVED with a maximum supervisory vacuum pressure of-3 psi(-207 mbar). - Refer to the Approval Chart and Design Criteria for requirements that must be followed. 3. TECHNICAL DATA '.. Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to: UL -250 PSI (17.2 bar) WWP FM - 175 PSI (12 bar)WWP Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2" NPT(15 mm BSPT) /� WARNING:Cancer and Reproductive Harm- Nominal K-factor: 5.6 U.S. (80.6 metric") ( l www.P65Warnings.ca.gov Glass-bulb fluid temperature rated to-65 °F (-55 °C) Metric K-factor measurement shown is in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass CW602N, UNS-C84400 or QM Brass Deflector: Stainless Steel UNS S30400 Pip Cap Shell - Stainless Steel UNS-S44400 Pip Cap Disc- Stainless Steel UNS-S30100 Belleville Spring - Nickel Alloy Pip Cap Seal - Polytetrafluoroethylene (PTFE) Compression Screw: Brass CW612N, CW508L, UNS-C36000 or UNS-C26000 Shipping Cap: Polyethylene Bulb: Glass, nominal 5 mm diameter Available Finishes and Temperatures: Finish Brass Chrome White Polyester Black Polyester ENT -- Suffix A F M-/W M-/B JN -- Temperature 135°F(57°C) 155°F(68°C) 175°F(79°C) 200°F(93°C) 286°F(141 °C) Open Suffix A B D E G Z Ordering Information: (Refer to Table 1 and the current Viking List Price Book.) 4. INSTALLATION Refer to appropriate NFPA, FM Global, and/or any other applicable installation standards. 5. OPERATION During fire conditions,when the temperature around the sprinkler reaches its operating temperature, the heat-sensitive liquid in the glass bulb expands, causing the bulb to shatter, releasing the pip cap assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler Model VK1001 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_020316 19.09.23 Rev 19.6 Replaces Form No. F 020316 Rev. 19.5 (added 250 PSI rated PN for UL) Page 2 of 4 NIKINGS VK1001 STANDARD TECHNICAL DATA RESPONSE UPRIGHT SPRINKLER (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com TABLE 1: ORDERING INFORMATION Instructions: Using the sprinkler base part number, (1)add the suffix for the desired Finish (2)add the suffix for the desired Temperature Rating. Size 1: Finishes 2: Temperature Ratings Sprinkler Base Part NPT BSPT Max.Ambient Ceiling No. Inch mm Description Suffix, Nominal Rating Bulb Color Temperature2 Suffix 19914 1/2 -- Brass A 135 °F (57 °C) Orange 100 °F (38 °C) A 19926 -- 15 Chrome F 155°F (68 °C) Red 100 °F (38 °C) B 230986 1/2 White Polyester 3,5 M-/W 175°F (79 °C) Yellow 150 °F (65°C) D Black Polyester 3,5 M-/B 200 °F (93 °C) Green 150°F (65 °C) E ENT 3,4$ JN 286 °F (141 °C) Blue 225 °F (107 °C) G OPEN -- -- Z Example: 19914MB/W =VK1001 with White Polyester Finish and 155 °F (68 °C) Nominal temperature rating. This sprinkler is to be installed into an area with a maximum ambient temperature of 100°F(38°C)meaning if the area will experience temperatures above the maximum ambient rating, you shall use a higher temperature-rated sprinkler. Accessories Sprinkler Wrenches (see Figure 1): A. Installer Wrench: Part No. 22055. B. Cabinet Wrench: Part No. 20901M/B. C. Straight Wrench: Part No. 22940MB Sprinkler Cabinet: A. Up to 6 sprinklers: Part number 01724A. B. 6-12 Sprinklers: Part number 01725A. Footnotes +. Where a dash(-)is shown in the Finish suffix designation,insert the desired Temperature Rating suffix.See example above. 2 Based on NFPA 13, NFPA 13R, and NFPA 13D.Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction.Refer to specific installation standards. 3. UL Listed as corrosion resistant. +_ FM Approved as a corrosion proofing coating for installation in corrosive environments. 5. The corrosion resistant and corrosion proofing coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments.Prior to installation,verify through the end-user that the coatings are compatible with or suitable for the proposed environment.For automatic sprinklers,the ENT coating is applied to all exposed exterior surfaces,including the waterway. 6. UL Listed for 250 PSI(17.2 bar)WWP. A B A 1-15/16" (49 mm) A 1/2" NPT 15 mm BSPT A 7/16" (11 mm) — Nominal Pipe Engagement Figure 1: Sprinkler Wrenches Figure 2: Sprinkler Dimensions Form No. F_020316 19.09.23 Rev 19.6 Page 3 of 4 NIIKING R VK1001 STANDARD TECHNICAL DATA RESPONSE UPRIGHT SPRINKLER (K5.6) The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com APPROVAL CHART Finish(es) Z Viking Standard Response Upright Sprinkler Temperature(s)--4 A 1 X KEY VK1001 K5.6 (80.6 metric) Escutcheon(s),If applicable Thread Size Listings and Approvals2 Sprinkler Base NPT BSPT cULus FM Part Number' Inch mm Approval Code(s) Maximum WWP Approval Code(s) Maximum WWP 19914 1/2 -- Al 175 PSI (12 bar) Al 175 PSI (12 bar) 19926 -- 15 Al 250 PSI (17.2 bar) Al 175 PSI (12 bar) 23098 1/2 -- Al 250 PSI (17.2 bar) Al 175 PSI (12 bar) Approved Temperature Rating Codes: A= 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C)and 286 °F (141 °C) Approved Finish Codes:e 1 = Brass, Chrome, White Polyester 3'4, Black Polyester 3'4, and ENT4,5 Footnotes 1 Base Part number is shown.For complete part number,refer to Viking's current price schedule. z This table shows the listings and approvals available at the time of printing.Check with the manufacturer for any additional approvals. 3 Other colors are available upon request with the same Listings and Approvals as the standard colors. 4 cULus Listed as corrosion resistant. 5 FM Approved as corrosion-proofing for installation in corrosive environments. DESIGN CRITERIA- UL cULus Listing Requirements: The Viking VK1001 Standard Response Upright Sprinkler is cULus Listed as indicated in Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light, Ordinary, and Extra Hazard occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers shall be followed. IMPORTANT:Always refer to Form No. F_091699 -Care and Handling of Sprinklers.Also refer to Form No. F_080614 for general care, installation, and maintenance information.Viking sprinklers are to be installed in accordance with the latest edition of Viking Technical Data,the appropriate standards of NFPA, LPCB,APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards,whenever applicable. DESIGN CRITERIA - FM FM Approval Reauirements: The Viking VK1001 Standard Response Upright Sprinkler is FM Approved as standard response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM Installation guidelines may differ from UL and/or NFPA criteria. IMPORTANT:Always refer to Form No. F_091699 -Care and Handling of Sprinklers.Also refer to Form No. F_080614 for general care, installation, and maintenance information.Viking sprinklers are to be installed in accordance with the latest edition of Viking Technical Data, the appropriate standards of NFPA, LPCB,APSAD,VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards,whenever applicable. Form No. F_020316 19.09.23 Rev 19.6 W , Page 4 of 4 VK1001 STANDARD NiiiuNG® TECHNICAL DATA RESPONSE UPRIGHT SPRINKLER (K5.6) The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1� / -.le- 1 e. 42' f q 'o 414" d g ,,++ 4 � � e Frame arms , IP parallel to *°* the pipe. , 1. Slide the wrench around the protective cap 2. Press the wrench downward to engage on the wrench flats. ,. 3. Rotate the wrench clockwise to install the sprinklers, NOTE: The sprinkler frame arms shall be parallel to the pipe. Figure 3: Installation (Installers Wrench) 1 2 3 • Frame arms 1. Carefully slide the wrench around the protective cap. =r pthelpl pi teo 2. Press the wrench downward to engage on the wrench flats. 3. Rotate the wrench clockwise to install the sprinkler. NOTE: The sprinkler frame arms shall be parallel to the pipe. `qrt «q�tz d�fa 3ip7: �s"t�' 4 Figure 4: Installation (Straight Wrench) Form No. F_020316 19.09.23 Rev 19.6 Replaces Form No. F 020316 Rev. 19.5 (added 250 PSl rated PN for UL) Page 1 of 6 R� TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email:techsvcs@vikingcorp.com 1. DESCRIPTION Viking Quick Response Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry sys- tems and preaction systems where it is necessary to prevent water or condensation from entering the drop nipple before sprinkler operation. They may also be installed in spaces subject to freezing and supplied from a wet system in an adjacent heated area. Viking Quick Response Dry Pendent Sprinklers are available in various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings have been investigated for installation in I' corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global has no approval classification for Polyester coatings as corrosion resistant.) NOTE: When installed in some corrosive environments, the Polyester finish may change color.This natural discoloration over time is not in itself an indica- tion of corrosion and should not be treated as such.All sprinklers installed in A WARNING:Cancer and Reproductive Harm- corrosive environments should be replaced or tested as described in NFPA 25 ( \ www.P65Warnings ca gov on a more frequent basis. 2. LISTINGS AND APPROVALS cOus cULus Listed: Category VNIV <'%«` FM Approved: Classes 2013 and 2015 NYC Approved: MEA 89-92-E Volume 15 Refer to Approval Chart 1 and Design Criteria on page 105d for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 105e for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: 175 psi (12 bar). Factory tested pneumatically to 100 psi (6.89 bar) Thread size: 1" NPT or 25 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric*)for all listed and approved lengths. * Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to-65 °F (-55 °C) Covered by the following U.S. Patents: 8,636,075 and 10,220,231 Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C26000 Bulb: Glass, nominal 3 mm diameter Viking Technical Data may be found on Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with The Viking Corporation's Web site at PTFE Tape http://www.vikinggroupinc.com. Compression Screw: Brass UNS-C36000 The Web site may include a more recent Pip Cap: Brass UNS-C31400 or UNS-C31600 Pip Cap Adapter: Brass UNS-C36000 edition of this Technical Data Page. Orifice: Copper UNS-C22000 or UNS-C11000 Tube: ERW Hydraulic Steel Tube Support(Internal): Stainless Steel UNS-S30400 Barrel: Steel Pipe UNS-G10260, Electrodeposited Epoxy Base finish Barrel End and Threads: QM Brass Sleeve (for Adjustable Standard style only): Brass UNS-C26000 or UNS-C26800 Escutcheon Materials: Adjustable Standard Dry Escutcheons: Brass UNS-C26000 or UNS-C26800 Form No. F 031793 19.06.24 Rev 19.1 Replaces Form F_031793 Rev. 15.1.P65 (ArtriPrt natant numhar . Page 2 of 6 NIKING® TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email:techsvcs@vikingcorp.com Recessed Dry Escutcheons: Cold Rolled Steel UNS-G10080 ENT Coated Adjustable and Recessed Escutcheons: Stainless Steel UNS-S30400 Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Dry Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish, the appropriate suffix for the temperature rating, and then the suffix for the length ("A" dimension)to sprinkler base part number. Order in a specific length noted as the "A" dimension. The "A" dimension is the distance from the face of the fitting (tee) to the desired finished surface of the ceiling. These sprinklers are listed and approved in lengths from 1-1/2"to 45-1/2"(38.1 mm to 1,156 mm)for the adjustable standard style, 3"to 47"(76.2 mm to 1,194 mm)for the plain barrel style,and 3-1/4"to 47-1/2"(82.5 mm to 1,207 mm)for the adjustable recessed style. Lengths exceeding the standard lengths are available,with no approvals,on a"made-to-order"basis: Recessed Dry Pendent up to 65-1/2" (1,664 mm).Adjustable Standard Dry Pendent up to 63-1/2"(1,613 mm). Plain Barrel Dry Pendent up to 65"(1,651 mm). Contact the manufacturer for more information. Finish Suffix: Brass =A, Chrome = F, White Polyester= M-/W, and ENT= JN Temperature Suffix: 155 °F (68 °C)= B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C)= G For example, sprinkler VK176 with a Chrome finish and a 155 °F (68 °C) temperature rating . • "`" length of 10" = Part No. 08383UFB10. Available Finishes And Temperature Ratings: Refer to Table 1. Wrench Flat Accessories: (Also refer to the "Sprinkler Accessories" section of the Protective j��xvurir,Nl Viking data book.) Sprinkler NOILYTWIIN 121.1 WNW Sprinkler Wrenches: III Shield A. Standard Wrench: Part No. 07297W/B (available since 1991) I`�l ) B. Wrench for recessed sprinklers: Part No. 07565W/B"* A% (available since 1991) '- **A'A"ratchet is required(not available from Viking). Sprinkler Guard: Chrome,with no listings or approvals,for installation on dry pendent sprinklers made after May 1994 only (Part No. 08954). VIKING U7297 Q Replacement Escutcheons: A.Adjustable Standard Dry Escutcheon: Base Part No. 07741 B. Recessed Dry Escutcheon Cup: Base Part No. 05459A Figure 1: Standard Sprinkler Wrench 07297W/B 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION MOM During fire conditions,the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the internal parts to open the _ waterway. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a Sprinkler Wrench uniform spray pattern to extinguish or control the fire. oused for stall be P Y g used installing recessed dry 6. INSPECTIONS, TESTS & MAINTENANCE sprinklers ma Refer to NFPA 25 for Inspection, Testing and `a_mil u�at ■l�r Maintenance requirements. II I II I Step 2, Carefully press it � Ir the wrench upward and i 7. AVAILABILITY � i turn slightly to ensure ` ly li The Viking Quick Response Dry Pendent Sprink- _ engagement with the ler is available through a network of domestic sprinkler wrench flats. and international distributors. See The Viking step 1, Carefully o*A 1/2• ratchet is Corporation web site for the closest distributor Slide the wrench required (Not avail- or contact The Viking Corporation. sideways around the able from Viking.) prinkler deflector, 8. GUARANTEE Figure 2: Wrench 07565W/B for Adjustable Recessed Dry Pendent Sprinklers For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_031793 19.06.24 Rev 19.1 Page 3 of 6 NEIKING, TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email:techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Te Bulb Color Ordinary 155°F (68°C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, and ENT Corrosion-Resistant Coating3'4: White Polyester and ENT in all temperature ratings Footnotes 'The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant Polyester and ENT coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts.These tests cannot and do not represent all possible corrosive environments. Note:These coatings are NOT cor- rosion proof. Prior to installation,verify through the end-user that the coatings are compatible with or suitable for the proposed environ- ment. Polyester and ENT coatings are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. 4 When installed in some corrosive environments,the Polyester finish may change color.This natural discoloration over time is not in itself an indication of corrosion and should not be treated as such. All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. For 'A' Dimension: 1. Determine the distance from the face of' the tee to the finished ceiling. 2. Round to the nearest 1/2' (12.7 mm) between 1-1/2' and 45-1/2" <38.1 mm and 1,156 mm). NOTE: The deflector will be located approximately 3-7/16' (87,3 mm) below the ceiling. with 1" (25.4 mm) upward and 1' (25.4 mm) downward adjustment. Deflector at minimum distance below ceiling. ANNIMIN NOTETo locate the deflector , at the minimum distance below the ceiling, with I I no downward adjustment A Minimum ceiling opening r-7/16" available, order the diameter: 1-3/4" (44.5 mm), (61.9 mm) dry pendent sprinkler Maximum ceiling opening I Minimum 1" (25,4 mm) shorter diameter: 2-1/4" (57 rim), than the 'A" dimension. ® 13/16' 1.11 NOTE: Finished-1 — (20.6 mm) To locate the deflector Ceiling at the maximum distance 4-7/16' below the ceiling, with 1 1/2' Sleeve finish (112.7 mm) no downward adjustment (38.1 mm) matches escutcheon. Maximum available, order the diameter dry pendent sprinkler 3-1/16' 1" (25.4 run) longer (77.8 mm) than the 'A' dimension. Deflector at maximum distance below ceiling Figure 3: Adjustable Standard Dry Pendent Sprinkler Form No. F_031793 19.06.24 Rev 19.1 Page 4 of 6 TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email:techsvcs@vikingcorp.com Approval Chart 1 (UL) Temperature KEY Quick Response Dry Pendent Sprinklers ; Finish A1X Maximum 175 PSI (12 bar)WWP � Escutcheon(if applicable) Sprinkler Thread Size Nominal K-Factor2 Order Length Increment Listings and Approvals" p SIN Style (Refer also to Design Criteria below.) Base Part No. NPT BSP U.S. metric' Inches mm cULuss NYC6 VdS LPCB (( 0 08383U Adjustable 1" -- 5.6 80.6 1/2" 12.7 Al,A5 Al -- -- -- -- VK176 16457U Standard -- 25 mm -- 80.6 1/2" 12.7 Al,A5 -- -- -- -- -- 08385U Adjustable 1" -- 5.6 80.6 1/4" 6.35 B2, B6 B2 -- -- -- -- VK180 16453U Recessed -- 25 mm -- 80.6 1/4" 6.35 B2, B6 -- -- -- -- -- 08387U Plain 1" -- 5.6 80.6 1/2" 12.7 A3 A4 -- -- -- -- VK172 16455U Barrel -- 25 mm -- 80.6 1/2" 12.7 A3 -- -- -- -- -- Approved Finishes and "A" Dimensions 1-Chrome or White Polyester'sprinkler with a Chrome or White Polyester Sleeve and Escutcheon Approved Temperature Ratings with"A"dimensions 1-1/2"to 45-1/2"(38.1 mm to 1,156 mm) A- 155 °F (68 °C), 175 °F (79°C), 200 °F (93 °C), 2-Chrome or White Polyester'with"A"dimensions 3-1/4"to 47-1/2"(82.5 mm to 1,207 mm) and 286°F(141 °C) 3-Chrome,Brass,White Polyester',or ENT'with"A"dimensions 3"to 47"(76.2 mm to 1,194 mm) B - 155 °F (68 °C), 175 °F (79°C), and 200 °F 4-Chrome or Brass with"A"dimensions 3"to 47"(76.2 mm to 1,194 mm) (93°C) 5 - ENT' sprinkler with an ENT' Sleeve and Escutcheon with "A" dimensions 1-1/2" to 45-1/2" (38.1 mm to 1,156 mm) 6-ENT'with"A"dimensions 3-1/4"to 47-1/2"(82.5 mm to 1,207 mm) Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths("A"Dimensions indicated above). 3 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process.Check with the manufacturer for any additional approvals. 5 Listed by Underwriter's Laboratories for use in the U.S.and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E,Vol. 15. 'cULus Listed as corrosion resistant. DESIGN CRITERIA- UL (Also refer to Approval Chart 1 above.) NOTE:When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-BI tees.When selecting other CPVC fittings, contact Viking Technical Services. cULus Listing Reauirements: Standard Dry Pendent Sprinklers are cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary Hazard occupancies. • The sprinkler installation and obstruction rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page DRY1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB,APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_031793 19.06.24 Rev 19.1 Page 5 of 6 NIIKING® TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings M149058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 2 (FM) Temperature KEY Quick Response Dry Pendent Sprinklers l;-Finish _ Maximum 175 PSI (12,bar)WWP A1X.--Escutcheon(it applicable) Sprinkler Base SIN Style Thread Size Nominal K-Factor2 Order Length Increment FM Approvals" Part No. NPT BSP U.S. metric Inches mm (Refer also to Design Criteria below.) 08383U 1" -- 5.6 80.6 1/2" 12.7 Al 16457U VK176 Adjustable Standard • -- 25 mm -- 80.6 1/2" 12.7 Al 08385U 1" -- 5.6 80.6 1/4" 6.35 B2 16453U VK180 Adjustable Recessed •-- 25 mm -- 80.6 1/4" 6.35 B2 08387U 1" -- 5.6 80.6 1/2" 12.7 A3 16455U VK172 Plain Barrel -- 25 mm -- 80.6 1/2" 12.7 A3 Approved Temperature Ratings Approved Finishes and"A"Dimensions A-155°F(68°C), 175°F(79°C),200°F(93°C) 1 - Brass, Chrome, White Polyester, or ENT' sprinkler with a Brass, Chrome, White Polyester, or and 286°F(141 °C) ENT5 Sleeve and Escutcheon with"A"dimensions 1-1/2"to 45-1/2"(38.1 mm to 1,156 mm) 2-Brass,Chrome,White Polyester,or ENT5 with"A"dimensions 3-1/4"to 47-1/2"(82.5 mm to 1,207 mm) B-155°F(68°C),175°F(79°C),and 200°F(93°C) 3-Brass,Chrome,White Polyester,or ENT' with"A"dimensions 3"to 47"(76.2 mm to 1,194 mm) Footnotes t Part number shown is the base part number. For complete part number,refer to current Viking price list schedule. 2 K-Factor applies for standard lengths("A"Dimensions indicated above). 3 Metric K-Factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any ad- ditional approvals. 5 FM approved as corrosion resistant. DESIGN CRITERIA-FM (Also refer to Approval Chart 2 above.) NOTE:When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-BI tees.When selecting other CPVC fittings, contact Viking Technical Services. - FM Aoproval Requirements; The Dry Pendent Sprinklers in the Approval Chart above are FM Approved as quick response Non-storage standard spray sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements,reference the latest applicable FM Loss Prevention Data Sheets(includ- ing 2-0)and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT:Always refer to Bulletin Form No. F 091699-Care and Handling of Sprinklers.Also refer to page DRY1-3 for general care, installation,and maintenance information.Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data,the appropriate standards of NFPA, FM Global, LPCB,APSAD,VdS or other similar organizations,and also with the provisions of governmental codes,ordinances,and standards,whenever applicable. 0uIIDi' iIIni' j A For "A" Dimension ._ � } 1. Determine the distance from face of tee to TFor 'A' Dimension: the finished ceiling. A2. Round to nearest 1/4 A 1. Determine the Minimum ceilingopening: (6.35 mm) between distance from o p g' \ Outside the face of -the 2-1/8' (54 mm) diameter, 3-1/4' (82.5 mm) and diameter: Ns, tee to the base 47-1/2' (1,207 mm). 1-5/16' h of the sprinkler, Maximum ceiling opening: (33,4 mm) 2. Round up to the 2-1/2" (63.5 mm) diameter. NOTE: Sprinkler will be recessed approximately (same as next highest 1/2' 5/16' (7.9 mm) above 1' (25 mm) (12.7 mm) incre- Schedule meet between 3' the finished ceiling with 40 pipe). (76,2 mm) and Adjustment: 5/8' (15.8 mm) vertical 47' (1,194 mm). 5/16' (7.9 mm). t__ adjustment available, 5/16' (7.9 mm) INIMMENI t-- ---- Finished ceiling 1-5/8' Minimum: 1' (25.4 mm) (48.3 mm) Maximum: 1-5/8' (42.1 mm) -3-1/16' (77.9 nm)-- I Form No. F 0 f1 a 4:1�1 us�t,�ble ed Dry Pendent Sprinkler Figure 5: Plain Barrel Dry Pendent Sprinkler Page 6 of 6 NIIKING;R TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email:techsvcs@vikingcorp.com Exposed Barrel Ambient Install 1 inch NPT threaded Temperature Ambient Temperature / end of dryendent sprinkler Deflector at 40'F/4'CI50'F/10'CI60'F/16'C p p minimum distance of Protected -- into the 1 inch NPT outlet below ceiling Area* at the Exposed Minimum Barrel / (1 of a malleable iron tee fitting Discharge End Lengtho Face of Tee Yper ANSI B 16,3 (Class 150) of the Sprinkler to Top of Cen. (ri Upto 2' (50.8 mm) In, (mm) In, (mm) In, (mm) -. 4 or cast iron threaded tee fitting 40'F (4•C) 0 0 0 ! per ANSI 164 (Class 125) only. adjustment available. 30°F (-1•C) 0 0 0 333333l, Note: 20'F ( 7'C> 4 (100) 0 0 Minimum ceiling opening diameter: 1-3/4' (44.5 mm) i de locate the 10°F (-12'C) 8 (203) 1 (25.4) 0 (Exposed I deflector at the Barrel> Maximum ceiling opening diameter: ,-, minimum distance 0 F (-18 C) 12 (305) 3 (76) 0 2-1/4' (57 mm). 2-7/16' below the ceiling, -10'F (-23'C)14 (356) 4 (102) 1 (25.4) (613 mm) with no upward -20'F (-29'C)14 (356) 6 (152) 3 (76) / Seal the clearance I Minimum adjustment avail- ! -30•F (-34'C)16 (406)8 (203)4 (102) - space around the able, order the to avoid leak- dry pendent sprink- -40'F (-40'C)18 <457)8 (203)4 (102) �. i. sprinklerler 1' (25.4 mm) -50'F (-46'C)20 (508)10 (254)6 (152) age of air into the ®II shorter than the RR= � 60'F ( 51'C)20 (508)10 (254)6 (152) J 13/16' protected area and 'A' dimension. ./ _ (206 mm) consequent formation Ceiling of condensate around the frame, which could \� Note: Inhibit operation or To locate the 1 1/2' (38.1 mm) i7 r� Sleeve finish cause premature opera- 4-7/16' deflector at the diameter matches tion, Refer to Figure (112.7 mm) maximum distance escutcheon 7 below, below the ceiling, Maximum with no downward If humidity and temp- =OMNI adjustment avail- 3-1/16' erature differential I able, order the (Protected Area) - - causes condensation dry pendent sprink- (77,8 mm) on the exposed dry ler 1' (25.4 mm) sprinkler, consider longer than the wrapping the exposed Deflector at A' dimension. barrel with insulation, maximum distance foam insulating tape, below ceiling or equivalent. wThe protected area refers to the area below the ceiling. The ambient temperature Is the temperature at the discharge end of the sprinkler. For protected area temperatures that occur between the values listed, use the next cooler temperature. w*The minimum required barrel length is not the same as the 'A' dimension. Refer to Figures 3-5 for the 'A' dimension. NOTE: Exposed minimum barrel lengths are inclusive up to 30 mph wind velocities. Figure 6: Dry Pendent Sprinkler Required Minimum Barrel Length Based on Ambient Temperature in the Protected Area (Adjustable Standard Dry Pendent Sprinkler is Shown) MIMI Seal �__ (or equivalent method) - Seal 11. /pi" a Clearance ® Insulated Opening IIII Ceiling ■ f I _.Ih_ ,Il Dry Sprinkler Seal on the Dry Sprinkler Seal Within the Ceiling Exterior of the Ceiling Figure 7: Dry Sprinkler Seal(Adjustable Standard Dry Pendent Sprinkler is Shown) Form No. F_031793 19.06.24 Rev 19.1 Replaces Form F_031793 Rev. 15.1.P65 (Added natPnt rnimharl ..:..... COSCO •:::::�: • Fire Protection l ire Prow(rim' iittcl Life Safety Specialists ip • • 1 e & Fi in s COSCO Fire Protection Inc. 2501 SE Columbia Way, Suite 100 Vancouver,WA 98661 Phone:360-883-6383 Fax: 360-883-6390 Toll Free:800-983-6383 Itt) State Pipe & Supply, Inc. THIS INFORMATION PROVIDED IS BASED ON ASTM GUIDELINES FOR WELDED PIPE SPECIFICATIONS AND ASTM REQUIREMENTS ACTUAL PIPE AND MATERIAL TEST REPORTS PROVIDED WOULD MEET OR EXCEED THESE GUIDELINES TEST REPORTS WOULD PROVIDE SPECIFIC AND ACTUAL DETAILS CONCERNING THE MECHANICAL AND CHEMICAL PROPERTIES OF THE ACTUAL PIPE,AS WELL AS ADDITIONAL TESTS RESULTS REQUIRED BY ASTM SCHEDULE 10** Black and Galvanized Steel ERW Pipe Pipe Size Test Pressure Nominal O.D. I.D. Weight/Foot psi 1" 1.315 1.097 1.410 700 1-1 14" 1.660 1.442 1.810 1200 1-1/2" 1.900 1.682 2.090 1200 2" 2.375 2.157 2.640 2300 2-1/2" 2.875 2.635 3 530 2500 3" 3.500 3.260 4.340 1290 4" 4.500 4.260 5.620 1000 5" 5 563 5.295 7.780 1010 6" 6.625 6.357 9.300 1020 8"'" 8.625 8.249 16.960 780 —8"wall thickness is 0 188, not SCH10 or 0 148"wall thickness COMPOSITION AND PROPERTIES Chemical and mechanical properties requirements are as prescribed by applicable ASTM standards edition January 2006. Chemical Requirements,Percent(Product) C Mn P S Other Specification Grade max max max max ASTM A53 A 0.250 0.950 0.05 0,045 - 1 Residual elements max.Cu 0.40.Ni-0.40 Cr-0.40,Mo-0 18 and V.08 These live elements combined shall not exceed 1% Mechanical Properties-Tensile Requirements Strength-psi. Yield Tensile Specification Grade Min Max Min Max ASTM A53 A 30,000 - 48,000 - NOTE Elongation requirements vary with nominal area of test specimen and specified minimum tensile strength of the steel grade 9615 S Norwalk Blvd.. Santa Fe Springs,CA 90670 . (562)695-5555 • FAX: (562)692-1054 •www.statepipe.com IS x, ,,, State Pipe 1 & Supply, Inc. ,, 1 THIS INFORMATION PROVIDED IS BASED ON ASTM GUIDELINES FOR WELDED PIPE SPECIFICATIONS AND ASTM REQUIREMENTS. ACTUAL PIPE AND MATERIAL TEST REPORTS PROVIDED WOULD MEET OR EXCEED THESE GUIDELINES. TEST REPORTS WOULD PROVIDE SPECIFIC AND ACTUAL DETAILS CONCERNING THE MECHANICAL AND CHEMICAL PROPERTIES OF THE ACTUAL PIPE,AS WELL AS ADDITIONAL TESTS RESULTS REQUIRED BY ASTM. SCHEDULE 40 Black and Galvanized Steel ERW Pipe Pipe Size Test Pressure Nominal O.D. I.D. Weight;Foot psi €; 1" 1.315 1.049 1.680 700 1-1/4" 1.660 1.380 2 270 1200 / 1-1/2'' 1.900 1.610 2.720 1200 2" 2.375 2.067 3.660 2300 I 2-1/2" 2.875 2.469 5.800 2500 I 3" 3.500 3.068 7.580 2220 4" 4.500 4.026 10.800 1900 5" 5.563 5.047 14.630 1670 ) 6" 6.625 6.065 18.990 1520 !: 8" 8.625 7.981 28 580 1340 COMPOSITION AND PROPERTIES Chemical and mechanical properties requirements are as prescribed by applicable ASTM standards edition January 2006. b Chemical Requirements,Percent(Product) C Mn P S Other Specification Grade max max max max ASTM A53 A 0.250 0.950 0.05 0.045 - 1 Residual elements max Cu-0 40 Ni-0 40,Cr-0 40,Mo-0.15 and V-08 These live elements combined shall not exceed 1% • Mechanical Properties-Tensile Requirements Strencth-psi. Yield `1 Tensile Specification Grade Min Max Min Max j ASTM A53 A 30,000 - 48,000 - }i NOTE Elongation requirements vary with nominal area of test specimen and specified minimum tensile strength 41 of the steel grade ' 1 jj to 9615 S. Norwalk Blvd., Santa Fe Springs, CA 90670 •(562)695-5555 FAX:(562)692-1054 www.statepipe.com . State Pipe 41111 & Supply, Inc. 3508 NE 68"- ST • Vancouver, WA 98661 (360)693-3650 • FAX (360) 750-1364 A 5RAN Company To whom it concern State Pipe & Supply is a master distributor of Seah Vina products for Fire Protection. We are a Seah company and Seah Vina is our sister Company. We certify all the Mill Test reports are matching the heat numbers on all the product we sell. We also have all the UL/FM certifications for all our Seah Vina product. If you have any other questions or concerns, feel free to contact me directly. dr• : :ectfully t>t-1,1 Ron Hartman General Manager „,,, SeAH Steel Vina Corporation Aso Ail ”` i �� ` Add:No 7,Street 3A.BienI-b a 17,il.t?ongNai.Vietnam ± s i 1 '�t Tel:84.613 833 733/84-613 836 997(sales) UREt.0 Rl1)i Fax:84.61 3 833 7341 84-613 836 991 I:rnall:seahsteelvina ihcm von vn =_ QAkA f(T•4I 4> SUBMITTAL DATA Rev 05:Sep. 07th, 2018 ASTM A53 TYPE E GRADE A CARBON STEEL PIPE SCOPE: Covers black and hot-dipped galvanized electric-resistance-welded Grade A carbon steel pipe. Pipe intended for mechanical and pressure applications and is acceptable for ordinary uses in steam,water, gas and air lines. SSV ASTM A53/A135/A795 is UL Listed and FM Approved, sizes 1-1/4"through 6" nominal for SCH10 and 8"x 0.188", and sizes I"through 8"nominal for SCH40, for use in Fire Sprinkler Pipe Applications. SSV ASTM A53Gr.A is UL enhance mark, sizes 1/2" through 8" nominal for SCH40 for Fuel Gas Piping field. Pipe is suitable for welding, threading, grooving and bending. Pipe is not intended for flanging. Produced to latest revisions of ASTM A53/A 53M, Federal Specification WW-P404 and ASME B36.tOM. HOT-DIPPED GALVANIZED The average weight of zinc coating shall be not less than 1.8 oz. per sq.ft.of surface(inside and outside) When galvanized pipe is bent or otherwise fabricated to a degree which causes zinc coating to stretch or compress beyond the limit of elasticity, some flaking of the coating may occur. HYDROSTATIC TESTING Hydrostatic test pressures liar plain-end pipe are indicated belmt. NPS light Weight- PSI Standard Weight - PSI Extra Strom Weight- PSI 700 850 2500 700 850 I" 2500 700 850 1-1/4" 2500 1200 1800 1-1/2" 2400 1200 1800 2" 1900 2300 2500 2-1/2" 1700 2500 2500 3" 1400 2220 _-_ �_- 2500 3-1/2" 1200 2030 2800 4" 1200 ..._.__..__.__ 1900 2700 1200 1670 2430 6" 1200 1520 2350 8" 1200 1340 2090 • END FINISH Plain End: NPS 1-1/2 and smaller: unless otherwise specified on order, end finish shall be at the option of the manufacturer. NPS 2 and larger: STD and SCH.80 weights: ends beveled to angle of 30°,+5",-0° with a root face of l/16"±l/32"(1.6mm ±0.8mm). Threaded: To ANSI Standard B 1.20.1 Couplings: To ASTM Standard A 865. CHEMICAL REQUIREMENTS Composition, max. % _ Carbon Manganese Phosphorus Sulfur *Copper *Nickel *Chromium *Molybdenum *Vanadium .30 1.20 .05 .045 .40 .40 .40 .15 .08 *The combination of these five elements shall not exceed 1.00% TENSILE REQUIREMENTS Tensile Strength, min. 48 000 psi Yield Strength, min. 30 000 psi Elongation in 2" Refer to A 53 Table x 4.1, latest revision-ASTM A53/A 53M BENDING TEST (COLD) FOR NPS 2 and UNDER: Degree of Bend Diameter of mandrel Standard 90" 12 x outside pipe diameter Close coiling 90" 12 x outside pipe diameter FLATTENING TEST-NPS 2-1/2 and GREATER As a test for quality of the weld, position the weld at 90" from the direction of force and flatten until the OD is 3/4 of the original outside diameter. No cracks shall occur along the inside or outside surface of the weld. DIMENSION and WEIGHTS BLACK PLAIN ENT) _ OD_. Sch.10 Sch.30 Sch.SO NPS Wall Weig UI. Wall Weig UL Wall Weig ht ht Inch mm CCR I bt COI Inch m LbJ m Inch mm Inch mm LW Ft Ft Ft 1,4" 840 21.3 ,109 2 77 85 147 3 73 1.09 '!;` 1 050 26.7 .083 2 11 0.86 113 287 113 154 3.91 1.48 I" I 315 33.4 109 2.77 1.41 .133 3.38 1.68 10 179 4.55 217 1.1/4" 1660 42.2 .109 2.77 1.81 7.3 140 3.56 2.27 1,0 191 485 3.00 1-1/2" 1.900 48.3 .109 2.77 2,09 5.8 .145 3.68 2.72 1.0 .200 5.08 3.63 2" 2.375 60 3 .109 2 77 2.64 4.7 154 3.91 3.66 1 0 218 5.54 5.03 2-1/2" 2875 730 120 3.05 3.53 3.5 .203 5.16 5.80 1.0 276 701 7.67 3" 3 500 88 9 .120 3.05 4.34 26 .216 5 49 7.58 1.0 300 7.62 10.26 3-1/2" 4.000 101.6 120 3.05 4.98 226 5.74 9.12 1.0 318 8.08 12.52 4" 4,500 114.3 .120 3.05 5.62 1.6 237 6.02 10.80 10 337 8.56 15.00 5" 5 563 141 3 134 3 40 7 78 1 5 258 6 55 14.63 1.0 375 9.52 20.80 6" 6,625 168.3 .134 3 40 9.30 1.0 280 7 II 18 99 1 0 432 10.97 28.60 8" 8.625 219.1 0.188• 4 78 16.96 2,1 322 8.18 28.58 1.0 .500 12.70 43.43 (*)Not Schedule 10. PERMISSIBLE VARIATIONS IN WALL THICKNESS Minimum wall thickness at any point shall not be more than 12.5% under nominal wall thickness specified. PERMISSIBLE VARIATIONS IN OUTSIDE DIAMETER NPS 1-1/2 and under ±0.16"(±0.4mm) NPS 2 and over ±1% PERMISSIBLE VARIATIONS IN WEIGHT PER FOOT Pipe shall not vary more than±10% from the standard specified. PRODUCT MARKING Each length of pipe '/z NPS and larger is continuously stenciled to show the manufacturer, the grade of pipe (ASTM A 53), the kind of pipe (ERW for electric-resistance-welded, A for Grade A,) the size (Sch. 80 for extra strong),and length. Stencil markings indicate UL Listing and FM Approval for sizes 1-1/4" through 8" nominal for SCH 10 and for sizes 1"through 8"nominal for SCH40 use in Fire Sprinkler Pipe Applications. UL enhance mark is printed on a plastic tag and attached on pipe bundles. SUBMITTAL INFORMATION PROJECT: CONTRACTOR: DAT : ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: BLACK I HOT-DIP GALVANIZED ,All information contained herein is accurate as known the time of publication. SSV reserves the right to change product specifications without incurring obligations. CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets ! 0 '4 �c vds LPCB ., VNIIPO SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLES 920 AND 92ON Victaulic Mechanical-Te Outlet provides a direct branch connection at any location a hole can be cut in pipe.The hole is cut oversize to receive a"holefinder" locating collar which secures the outlet in position permanently.A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size,with the same or differing branch size connections. NOTE:Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded STYLES 920 AND 920N STYLE 920 CROSS outlet.Specify choice on order. Units are supplied painted with plated bolts.Galvanized hous- PATENTED ings are available,supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe.They may also be used on high density polyethylene or poly- butylene(HDPE)pipe. Pressure ratings on HDPE are dependent on the pipe rating.Contact Victaulic for ratings on other pipe.Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90°angle when permanently attached to the pipeline surface. Additionally,the Vic-Tap Ile hole cutting tool,which allows for hole cutting capabilities on pressurized systems,utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit.See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating:Ductile iron conforming to ASTM A-536,grade 65-45-12,with orange enamel coating. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. • Optional: Hot dipped galvanized Gasket:(Specify choice*) • Grade"E"EPDM EPDM(Green color code).Temperature range—30°F to+230°F/-34°C to+110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold+86°F/+30°C and hot+180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade"T"nitrite Nitrile(Orange color code).Temperature range—20°F to+180°F/-29°C to+82°C. Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over+150°F/+66°C or for hot dry air over+140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ictaulid Rt..5 t}a: 11 OP l CARBON STEEL PIPE- HOLE CUT PRODUCTS 11.02' Mechanical T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS D .,i.. V;h ht E ach Run x Branch i i Hole V z k V 4 Female I Nominal Size 920 I Diameter T" TM. Grv. W Y Z 1 Thd. I Grv. Inches I or 1 psi +0.13 Inches Inches Inches Inches Inches Inches Lbs. 11 Lbs. Y mm 1 920N 1 kPa -0.00 mm mm mm mm mm mm kg kg r } 2 x '/z(a)° 920N 500 1.50 2.00 2.53 _ 1.61 5.35 2.75 3.1 _ ...1V 50 15 3450 38.1 51 64 41 136 70 1.5 /` �� iii I[i�11 ' (a)° 920N 500 1 50 1.97 2.53 _ 1.61 5.35 2.75 3.1 ���_ 20 3450 38.1 50 64 41 136 70 1.5 1(a)5 500 1.50 1.85 2.53 - 1.61 5.35 2.75 3.0 \ ± t 25 920N 3450 38.1 47 64 41 136 70 1.4 - 1 Y(a)t°' 920N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 GROOVED OUTLET 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 11/2(a)t° 920N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 41 136 83 1.7 15 Y rt Z-► 2'/2 /z(15§° 500 380 2.21 2.74 1.82 4 2.75 3.0 - 65 x 15 920N 3450 38.1 56 70 46 143 70 14 t r PR 1 3/4(a)5G 920N 500 1.50 2.18 2.74 1.82 5.64 2.75 3.0 V die i� ter T 4F:--h 20 3450 381 SS 70 46 143 70 1.4 1(a)§° 920N 500 1.50 2.06 2.74 _ 1.82 5.64 2.75 2.9 �r I" 25 3450 38.1 52 70 46 143 70 1.4 I I 1 Y,t(a)G, 920N 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 H-� 32 3450 44.5 58 76 83 46 160 76 1.7 1.5 FEMALE THREADED OUTLET 1 1/2t(a)G 920N 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 33 40 3450 50.8 58 76 83 46 159 83 1.7 1.6 Yz(a) 300 1.50 2.22 2.75 _ 2.25 6.46 3.18 3.9 76.1 x 15 920N 2065 38.1 56 70 57 164 81 1.8 • Provides a direct branch connection at 3/4(a) 920N 300 1.50 2.19 2.75 - 2.25 6.46 3.18 3.9 any location where a hole can be cut 20 2065 381 56 70 57 164 81 1.8 in the pipe 1(a) 920N 300 1.50 2.07 2.75 _ 2.25 6.46 3.18 3.8 _ 25 2065 38.1 53 70 57 164 81 1.7 • A pressure responsive gasket provides 11/4(a)a 920N 500 1.75 2.30 3.00 331 1.92 6.29 3.00 3.5 3.2 the seal 32 3450 44.5 58 76 84 49 160 76 1.6 1.5 1 14(a)° 920N 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 • Request Publication 11.03 for 40 3450 508 58 76 84 49 160 83 1.6 1.5 Mechanical-T cross assemblies 3 '/_(a)o 500 1.50 2.52 3.05 - 2.28 6.15 2.75 3.4 80 x 15 920N 3450 38.1 64 78 58 156 70 1.6 • Pressure rated up to 500 psi/3450 kPa 3(a)° 920N 500 1.50 2.49 3.05 2.28 6.15 2.75 3.4 on steel pipe;also available for use 20 , 3450 38.1 63 78 - 58 156 70 1.6 with HDPE pipe 1(a) 920N 500 1.50 2.38 3.06 _ 2.28 6.15 2.75 3.3 _ 25 3450 38.1 61 78 58 156 70 1.6 • Sizes from 2 x 1/2"/50 x 15 mm iv,(a)fa 920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 through 8 x 4"/200 x 100mm 32(b) 3450 44.5 65 83 90 58 156 76 1.8 1.8 11/2(a)ta 920N 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8 40(b) 3450 50.8 71 89 90 58 156 83 1.9 1.8 2(a)a 920N 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 3450 63.5 70 89 90 58 172 99 23 2.1 3Yz 2 500 2.50 3.00 3.75 244 6.72 388 _ 3.8 90 x 50 920N 3450 63.5 76 95 62 171 99 , 18 IMPORTANT NOTES: TABLE CONTINUED ON PG.3 Style 920 and Style 920N housings cannot be **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). mated to one another t Available with grooved or female threaded outlet.Specify choice on order. to achieve cross connections. t Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 2'/z"BSPT clearly on order. §Vds approved for fire protection services °LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iCtaUlia 11-02 2 REV M . CARBON STEEL PIPE-HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Style Max.Work Approx. Size No. Pressure@ Dimensions Weight Each Ran x branch 'rszrr r "f s. Nominal Size 920 a 4 Y > Z ► Inches or fir!`. ..7a ;.,, t t•M;w,,„ `' .1 �` '`, ° nE r = roes 920N irPa 0.00 mm mm mm anm mrn ins kg kg _ TABLE CONTINUED FROM PAGE 2 1 � f�1 �� 5 + 4 x /(a)a 920N 500 1.50 3.03 3.56 _ 2.69 701 2.75 3.7 m l� 13111 r rR I 100 15 3450 38.1 77 90 68 178 70 1.8 ► 3/4(a) 920N 500 1.50 3.00 3.56 2.69 7.01 2.75 3.7 @4W W I�II 20 3450 38.1 76 90 68 178 70 1.8 1 1(a)D920N 500 1.50 2.88 3.56 _ 2.69 7.01 2.75 3.6 25 3450 38.1 73 90 68 178 70 1.8 GROOVED OUTLET 11/4(a)to 920N 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 32(13) 3450 44.5 78 96 102 68 178 76 1.9 1.8 1 Yz(a)to 920N 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 4 Y 1 1 Z--4. 40(b) 3450 50.8 83 102 102 68 178 83 2.0 1.9 t PI 2(a)to 920N 500 2.50 3.25 4.00 4.00 2.69 7.01 3.88 5.0 4.6 50 3450 63.5 83 102 102 68 178 99 2.3 2.1 V ails a� T I 21/2(a)t 920 500 275 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 65 3450 69.9 73 102 102 68 186 118 2.6 2.3 1 500 2 75 2.88 _ 4.00 2.69 7.34 4.63 _ 6 4 w 76.1 mm 920 3450 69.9 73 102 68 186 118 2.9 + 3(a)t 920 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 64 80 3450 88.9 84 114 105 68 196 130 3.8 2.9 FEMALE THREADED OUTLET 1'Y4(a)u 500 1.75 3.08 3.78 _ 2.63 764 3.05 5.0 _ 108.0 x 32 920N 3450 44.5 78 96 67 194 78 2.3 1'h(a)o 920N 500 2.00 3.28 4.00 - 2.63 7.64 3.25 5.0 - • Provides a direct branch connection at 40 3450 50.8 83 102 67 194 83 2.3 any location where a hole can be cut 2(a) 920N 500 2.50 3.25 4.00 2.63 7.64 4.00 4.0 - in the pipe 50 3450 63.5 83 102 - 67 194 102 1.9 76.1 mm 920 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 7.8 • A pressure responsive gasket provides 3450 69.9 73 102 102 67 194 109 3.6 3.5 the seal 3(a) 920 500 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 80 3450 88.9 84 114 114 67 194 124 3.1 3.0 • Request Publication 11.03 for 5 1 k(a)t 500 2.00 4.03 4.75 4.75 3.16 9.70 3.69 7.4 7.6 Mechanical-T cross assemblies 125 x 40 920 3450 50.8 102 121 121 80 246 94 3.4 3.4 2(a)t 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 • Pressure rated up to 500psi/3450kPa 50 920 3450 63.5 102 121 121 80 246 111 37 3.6 on steel pipe;also available for use 21/2(a)t 920 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9 with HDPE pipe 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 76.1 mm o 920 500 2.75 3.75 _ 4.75 3.16 9.70 4.63 8.0 • Sizes from 2 x W/50 x 15mm 3450 69.9 95 121 80 246 118 3.6 through 8 x 47200 x 100 mm 3(a)t 920 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 88.9 97 127 118 80 246 135 3.8 4.0 2 500 2.50 3.75 4.50 - 3.17 8.00 3.88 8.0 - 133.0 x 50 920N 3450 63.5 95 114 81 203 99 3.6 3 500 3.50 3.81 5.00 _ 3.00 9.46 5.31 8.0 80 920 3450 88.9 97 127 76 240 135 3.6 TABLE CONTINUED ON PG.4 IMPORTANT NOTES: **Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet.Specify choice on order. mated to one another # Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 21/2"BSPT clearly on order. §Vds approved for fire protection services n LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. /CtaUllid U(6.,r (s' I 1 t) 3 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Style Max.Work Appror, No. Pressure C Dime'nc ons WE Each I Run x Branch '' 1 Hai' V r.k V% I Female Nomina1 Sue 1 920 I 'Diameter T- Thd Grv, W Y Z Thd. {' Ore ittihr; or p,I o-0. .... s Iti,. _ .,,c;Inches Inches hn..hes Lbs. I Lbs4 . Y r 14---Z --ilmT 920N j It," 0.," ,'i ,", • :atnm mrn mm kg ' kg ISM TABLE CONTINUED FROM PAGE 3 �� 139.7 x 1 Yx t 920N 500 2.00 3.78 4.50 - 3.30 8.23 3.25 70 /.5r i-� t5r 1 40 3450 50 8 96 114 84 209 83 3 2 2 t 920N 500 2.50 3.75 4.50 - 3.30 8.23 3.88 9.0 _ Ai 3450 63 5 95 114 84 209 99 4.1 \ VV 6 11.4(a) 500 1.75 4.43 5.13 5.13 3.79 9.15 3.25 5.1 4.8 150 x 32(b) 920N 3450 44.5 112 130 130 96 232 83 2.3 2.2 GROOVED OUTLET 1 V2(a)t° 920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40(6) 3450 50.8 112 130 130 96 232 83 2.4 2.3 2(a)to 920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 y_____a I -Z ►1 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 216 920 500 2.75 4.01 5.13 5.12 3.69 10.51 4.63 8.3 7.6 r 1111111 _ 65 3450 69.9 110 130 130 94 267 118 3.8 3.4 V ,rir �� tip T 76.1 mm 6' 920 500 2.75 4.15 - 5.21 369 10.51 4.63 _ 8.4 �> �� 1�1 ( 3450 69.9 105 132 94 267 118 3.8 3(a)t 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 11111/4444.11) + I v I 80 920 3450 88.9 110 140 130 94 267 135 4.5 3.8 l-1 4(a)fx 500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1 100 920 3450 114.3 97 146 137 94 267 159 4.6 4.6 FEMALE THREADED OUTLET 12(a) 500 2.00 4.41 5.13 - 3.63 9.40 3.25 7.8 _ 159.0 x 40 920N 3450 50.8 112 130 92 239 83 3.5 2(a) 920N 500 2.50 4.38 5.13 3.63 9.40 3.88 8.0 • Provides a direct branch connection at 50 3450 63.5 111 130 92 239 99 3.6 any location where a hole can be cut 76.1 mm 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 in the pipe 3450 69.9 111 140 130 92 239 118 4.3 4.3 3 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 • A pressure responsive gasket provides 80 920 3450 88.9 110 140 130 92 239 135 3.7 6.4 the seal 108.0mm 920 500 4.50 4.45 - 5.38 3.63 9.40 6.12 _ 10.0 3450 114.3 113 137 92 239 155 4.5 • Request Publication 11.03 for 4 500 450 3.81 5.75 - 3.63 9.40 6.25 18.0 _ Mechanical-T cross assemblies 100 920 3450 114.3 96.80 146 92 239 159 8.2 TABLE CONTINUED ON PG.5 • Pressure rated up to 500 psi/3450 kPa CC Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). on steel pipe; also available for use t Available with grooved or female threaded outlet.Specify choice on order. with HDPE pipe t Center of run to end of fitting, • Sizes from 2 x 1/2"/50 x 15mm # Female threaded outlets are available to NPT and BSPT specifications. through 8 x 4"/200 x 100 mm @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 21/2"BSPT clearly on order. §Vds approved for fire protection services LPCB approved for fire protection services IMPORTANT NOTES: 0 Approved for use in China by Tianjin Approvals Company. Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICtaUI1Gr 11 01 4 R E V M CARBON STEEL PIPE-HOLE CUT PRODUCTS 1 1.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Style Max.Work Apra._ No. Pressure@ Dimensions Wci;;n.t Fad, Run x Branc ' resaassaa . V�'. {r I Female Nominal Size 920 T Ihd. Gni. W Y Z Tint i Grv. . InchesI or j �" Y > 't-Z nun 920N I kPaxY 'i?. rnrn mm kg k8 - ,,,. .....______4 1t TABLE CONTINUED FROM PAGE 4 ^� �/ 1651 x 1 920N 500 50 3.88 4.56 _ 3.79 9.34 2.75 8.0 - r r �� lin 25 3450 38.1 99 116 96 237 70 3.6 -- v „AD D 920N 500 1.75 4.43 5.13 _ 3.79 9.34 3.25 8.4 32 3450 44.5 113 130 96 237 83 3.8 1.... 1'/2(a)tn' 920N 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 5.4 40 3450 50.8 112 130 130 96 237 83 3.8 2.4 GROOVED OUTLET 2(a)t 920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 50 i 3450 63.5 111 130 130 96 237 99 3.9 2.7 76.1 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 4 3450 69.9 110 130 132 92 267 118 3.9 3.4 3(a)t A 920 500 3.50 4.31 5.50 5.13 3.63 1051 5.31 10.2 84 80 3450 88.9 110 140 130 92 267 135 46 3.8 Vi ,oIiI 4(a)In 920500 450 3.81 5.75 5.38 363 10.51 6.25 10.5 84100 3450 114.3 97 146 137 92 267 159 4.8 38 '� 8 2(a)t 500 2.75 5.44 6.19 6.25 4.81 1242 4.50 11.6 11.6 200 x 50 920 3450 69.9 138 157 159 122 316 114 5.3 5.3 J-1 2 r/z(a)t 500 2.75 507 6.19 6.19 4 81 12.42 4.50 11 6 11.6 65 920 3450 69.9 129 157 157 122 316 114 5.3 5.3 FEMALE THREADED OUTLET 76.1 mm a 920 500 2.75 5.25 _ 6.25 4.81 12.42 4.56 - 11.6 3450 69.9 133 159 122 316 116 5.3 3(a)to 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6 • Provides a direct branch connection at 80 920 3450 88.9 135 165 165 122 316 135 5.7 5.3 any location where a hole can be cut 4(a)to 920 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.5 in the pipe 100 3450 114.3 122 171 162 122 316 159 6.9 5.7 ..Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). • A pressure responsive gasket provides t Available with grooved or female threaded outlet.Specify choice on order. the seal * Center of run to end of fitting. • Request Publication 11.03 for # Female threaded outlets are available to NPT and BSPT specifications. Mechanical-T cross assemblies @ See page 7 for Fire Protection approvals and pressure ratings: • Pressure rated up to 500 psi/3450 kPa (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. on steel pipe;also available for use (b)For 76.1 mm threaded outlet,specify 2i/i'BSPT clearly on order. with HDPE pipe §Vds approved for fire protection services ❑LPCB approved for fire protection services • Sizes from 2 x 1750 x 15mm 0 Approved for use in China by Tianjin Approvals Company. through 8 x 47200 x 100mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. , www.victaulic.com 'CtaUIlc' VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. RE 0 tv% 11 02 f CARBON STEEL PIPE-HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N . FLOW DATA Flow test data has shown that the total head loss between point(1)and(2)for the Style 920,920N and 929 Mechanical-T®fittings can best be expressed in terms of the pressure difference across the inlet and branch.The pressure difference can be obtained from the relationship below. 0 C0 and Kv Values Values for flow of water at+60°F/+16°C are shown in the table below. 14.—M P__ Formulas for Cv/Kr Values: DP = Q2 Where: �P = Q2 Where: / \� C2 Q=Fbw(GPM) K , dui 4P=Pressure Drop(psi) LP=pressure Drop(bar) Q = C x DP C =Flow Coefficient Q = K x OP K =Flow Coefficient Exaggerated for clarity Equivalent Length of Outlet Size Schedule 40 Carbon Steel Pipe • (per UL 213,Sec.16) OUTLET SIZE (C=120)t FT CA,.Value • NOMINAL ACTUAL ,e, DIAMETER 0.D. In/rum Inlmrn GROOVED THREADED GROOVED THREADED • 0.840 11 15 21.3 • 2 9.4 . . .... 3/a . 1.050 16 20 26.7 4 13.7 1 1.315 21 • 2 33.7 8 1.8 1 Y, 1.660 i 5 Y2 6 50 48 32 42.7 42.9 41.1 1 1 1.900 • 53 53 40 98.3 11 11 45.4 45.4 2 2.375 112 104 50 60.3 9 10'h 96 89.1 7 V 2.875 119 150 65 73.0 20 12 Yz 102 128.5 3.000 • • 161 76.1 mm 76.1 16* 138.1 3 3.500 249 237 80 88.9 14 • • 15/2 213.4 203.1 4 4.500 421 401 100 114.3 20 22 360.8 343.6 t Hazen-Williams coefficient of friction is 120. Pipe with a wall thickness of 0.165in./4.2mm. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.81 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICt.'eaulld 11 (12 6 REV M "CARBON STEEL PIPE-HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies.Contact Victaulic for performance on other pipe and the latest listings and approvals. Approval Agency Run Siz' outlet Sizr P pe Rated Working Pressures—psi/kPa Actual f#� a ? ,..,,1 Ford #t r, l )``€,4 to4,4114 zM t ,4 9, P .. ,. Nominal Outside g ,. ¢ '_;.. : t1, Vds --'— Size Diameter Inches/mm 'inches/mm Inches/mm Schedule UI- ULC FM LPCB (Style 920) (Style 920N)A 21/2-6 2.875-6.625 All 10,40 400 400 400 290 232 362 65-150 73.0-168.3 2755 2755 2755 1999 1599 2496 21/2-4 2.875-4.500 All DF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 21/2-4 2.875-4.500 All SF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 6 6.625 3 4 10 300 300 250 290 232 362 150 168.3 2065 2065 1724 1999 1599 2496 6 6.625 3,4 30,40 150 168.3 300 300 300 290 232 362 2065 2065 2065 1999 1599 2496 8 8.625 21/2 10,40 400 _ _ _ 145 200 219.1 2755 1000 8 8.625 34 (0 300 250 _ 145 — 200 219.1 2065 1724 1000 8 8.625 3,4 30,40 300 _ 300 _ 145 — 200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4-8"/100-200 MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve.The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 4"/100mm, T 5"/125mm,67150mm and 8Y200 mm diameter pipe.The Style 931 comes with a 21/2"/65mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter(GFCI)in accordance with safety codes. 1 ' For more information, refer to publication 24.01. i .. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.CD2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ictaulll[, ul:v --''.1 1102 7 CARBON STEEL PIPE HOLE CUT PRODUCTS 11 .02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing.Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 11.02 1480 REV M UPDATED 03/2012 ✓ctaulic VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. - - - IF'S CARBON STEEL PIPE HOLE CUT PRODUCTS 10.52 FireLock® Outlet-I c®. ® VdS LPCB �. SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating i ,14,and 1"/15,20 and 25mm outlets for directly connecting sprinklers,drop nipples,sprigs,gauges,drains and other outlet products.Available for 134 through 76.1 mm/32 to 76.1mm piping systems,Style 922 outlets are UL/ULC Listed,LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. 111 The locating collar engages into the hole prepared in the pipe.When tightened,the assembly compresses the gasket onto the OD of the pipe.The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard,lightwall,Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing:Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. Gasket: • Grade"E"EPDM-Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc.and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services up to the rated working pressure using the Grade"E"Type A Gasket System. Bolts/Nuts:Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: • Orange enamel(North America,Latin America,Asia Pacific) • Red enamel(Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. jctaVlie E V i 1(1 r2 1 IPS CARBON STEEL PIPE-HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T STYLE 922 DIMENSIONS N ,,-i., i• Approx. Dimensions-inches/millimeters Weight Each Run X Branch i +0 061+1.5 '„ Y Z FPT. 1 -0.00/-0.0 T' ,.� .. : 1'/a '/ 13/16 1.30 183 1.10 3.87 2.56 1.0 V ��� 1 C\ 32 X 15 302 33.0 46.5 27.9 98.3 65.0 045 1 :� TJ \\ ?Cy '/< 13/16 1.28 1.83 3.87 2.56 1.1 ■ i ' I 20 30.2 32.5 46.5 27.9 98.3 65 0 0.50 - i, iris, iW ►�riq 1 13/16 1.52 2.18 1.10 3.87 2.56 1.2 NA 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 11/2 Y 13/16 1.42 1.95 1.22 4.08 2.56 1.2 40 X 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 34 13/16 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 13/16 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 65 0 0.59 2 h 13/16 166 2.19 1.46 4.60 2.56 1.3 50 X 15 30.2 42.2 55.6 37.1 116.8 65 0 0.59 3/4 13/16 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41 7 55.6 37.1 116.8 65.0 0.64 1 13/16 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 21/2 '/ 13/16 1.91 244 1.71 5.40 2.56 1.6 65 X 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 3 1 3/16 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 13/16 2.13 2.79 1.71 5.40 2.56 1.6 25 30,2 54.1 70.9 43.4 137.2 65.0 0.73 76.1 mm X 1/21 3/16 1.91 2.44 1.71 5.50 2.56 1.6 15 30.2 48.5 62.0 43.4 139.7 65.0 0.73 3/4 13/16 1.89 244 1.71 5.50 2.56 1.6 20 302 48.0 62.0 43.4 139.7 65.0 0.73 1 13/16 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT(optional) male pipe threads only.Use of male threaded products with special features,such as probes,dry pen- dent sprinklers,etc.,should be verified as suitable for use with this Victaulic product.Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads(dimensions are approximate). www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. jctaulid i 0 52 2 REV G IPS CARBON STEEL PIPE-HOLE CUT PRODUCTS 1 0.5 2 FireLock® Outlet-T STYLE 922 PERFORMANCE Equivalent Length of 1 inch Schedule 40 Steel Pipe(per UL 213,Section 16)(C=120)-,FT Inches/rum Feet/meters 116 X 1 8.5 32 25 2.6 1/a X 1 8.5 40 25 2.6 2 X 1 8.5 50 25 2.6 Z/ X 1. 8.5 65 25 2.6 76.1mm X 1 8.5 25 2.6 •Hazen-Williams coefficient of friction is 120 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY OD2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ictauIiC° REV tz IPS CARBON STELE PIPE HOLE CUT PRODUCTS 10.52 FireLock ' Outlet-T STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing.Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 �ctauIic VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. Victaulic® FireLockTM Fittings ✓ctaulid 10.03 • 1.0 PRODUCT DESCRIPTION Available Sizes • 11/a—8'/DN32—DN200 Maximum Working Pressure • Pressure ratings for Victaulic FireLockTM Fittings conform to the ratings of Victaulic FireLock EZTM Style 009N couplings (refer to publication 10.64 for more information). Application • FireLockTM fittings are designed for use exclusively with Victaulic couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. • Connects pipe, provides change in direction and adapts sizes or components Pipe Materials • Carbon steel 2.0 CERTIFICATION/LISTINGS ©1s ® LPCB vds ( E EN 10311 Regulation(EU) No.305/2011 3.0 SPECIFICATIONS- MATERIAL Fitting: Ductile iron conforming to ASTM A536, Grade 65-45-12. Fitting Coating: ❑ Orange enamel. ❑ Red enamel in Europe, Middle East, Africa, and India. ❑ Optional: Hot dipped galvanized. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date i victaulic.com 10.03 1539 Rev N Updated 09/2017 ©2017 Victaulic Company.All rights reserved. 1 ✓ctaulic: victaulic.com • 4.0 DIMENSIONS .-ct°E.j c i(4- -ro i to V" ii % CtoE 0 0 fi _K.1 0 C -0 - -4 br t of J�✓, __ tE e e No.001 No.003 No.002 No.006 1 No.001 No.003 No.002 No.006 90°Elbow 45°Elbow Straight Tee Cap Actual Approximate Approximate Approximate Approximate Nominal Outside 1 Weight Weight Weight Weight Size Diameter C to E Each C to E Each C to E Each T Each inches inches inches lb inches lb inches lb inches lb DN mm mm kg mm kg mm kg mm kg 1 Y4 1.660 - - - - - - 0.82 0.3 DN32 42.4 - - 21 0.1 _ 11/2 1.900 - - _ - - - 0.82 0.4 DN40 48.321 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 DNSO 60.3 70 0.8 51 0.8 70 1.1 22 0.3 2 Y 2.875 1 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 73.0 76 1.4 57 1.0 76 1.6 22 0.5 3.000 3.00 3.30 2.25 2.4 3.00 3.8 - 0N65 76.1 76 1.5 57 1.1 76 1.7 3 1 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 ' DN80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 _ 4.250 4.00 5.7 3.00 5.1 4.00 7.5 108.0 102 2.6 76 2.3 102 3.4 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 DN100 ! 114.3 102 3.0 76 2.5 102 3.9 25 1.1 _ 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 141.3 4 124 5.7 83 3.8 124 7.1 25 1.9 5.500 4.88 12.4 3.25 8.2 4.88 15.4 DN125 139.7 r 124 5.6 82.6 3.7 124 6.9 I 6.250 5.50 12.6 3.50 9.2 5.50 17.9 Ez4i.ey'�.. - - r 158.8 140 5.7 89 4.2 140 8.0 6 1 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 DN150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 6.500 5.43 17.6 3.50 11.4 5.50 22.0 165.1 140 7.9 89 5.2 140 9.9 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 DN200 i 219.1 173 11.6 108 9.3 176 17.6 29 5.8 _ ,' 8.515 6.81 23.1 - - 6.94 33.6 - - 1` I 216.3 173 10.5 I - - 176 15.2 - - • • 10.03 1539 Rev N Updated 09/2017 ®2017 Victaulic Company.All rights reserved. victaulic.com 2 jotaulic? • •5.0 PERFORMANCE Flow Data Size Frictional Resistance Equivalent of Straight Pipe' No.002 �- Actual Elbows Straight Tee Nominal Outside No.001 No.003 Size Diameter 90°Elbow 45°Elbow Branch Run inches inches feet feet feet feet DN mm meters meters meters meters 1'/4 1.660 - - - - DN32 42.4 - - - - _ j DN40 48.3 - I 2 2.375 3.5 1.8 8.5 3.5 DN50 60.3 1.1 0.5 2.6 1.1 21/2 2.875 4.3 2.2 10.8 4.3 73.0 1.3 0.7 3.3 1.3 3.000 4.5 2.3 11.0 4.5 DN65 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 DN80 88.9 1.5 0.8 4.0 1.5 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 1 3.4 I 16.0 + 6.8 DN100 j 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 141.3 2.6 1.3 6.4 2.6 5.500 8.3 4.1 20.6 8.3 DN125 139.7 2.5 1.3 6.3 2.5 1 6.250 9.4 4.9 25.0 9.6 i 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 DN150 168.3 3.0 1.5 7.6 3.0 _ 6.500 9.8 4.9 24.5 9.8 165.1 3.0 1.5 7.5 3.0 t _ 8 I 8.625 13.0 5.0 33.0 13.0 DN200 ]1 219.1 4.0 1.5 10.1 4.0 8.515 13.0 - 33.0 13.0 216.3 4.0 - 10.1 4.0 ' The flow data listed is based upon the pressure drop of Schedule 40 pipe. • • 10.03 1539 Rev N Updated 09/2017 ®2017 Victaulic Company.All rights reserved. victaulic.com 3 ✓ctaulic' victaulic.com 6.0 NOTIFICATIONS General Notes NOTE: When assembling FireLock EZTM couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZTM Style 009N/009H couplings, use FireLockTM No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H/009N couplings. 7.0 REFERENCE MATERIALS 10.64:Victaulic®FireLockTur Rigid Coupling Style 009N 10.02:Victaulic®FireLockTM Rigid Coupling Style 005H with Vic-PIusTM Gasket System 29.01:Victaulic®Terms and Conditions of Sale • User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products for a particular end-use application,in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications,and the applicable building codes and related Victaulic reserves the right to change product specifications,designs and standard regulations as well as Victaulic performance,maintenance,safety,and warning equipment without notice and without incurring obligations. instructions.Nothing in this or any other document,nor any verbal recommendation, Installation advice,or opinion from any Victaulic employee,shall be deemed to alter,vary,supersede, Reference should always be made to the Victaulic installation handbook or installation or waive any provision of Victaulic Company's standard conditions of sale,installation instructions of the product you are installing.Handbooks are included with each shipment guide,or this disclaimer. of Victaulic products,providing complete installation and assembly data,and are available Intellectual Property Rights in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warranty product,service,or design is intended,or should be constructed,to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patentor other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design,or as a recommendation for the use of such Trademarks material,product,service,or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right.The terms"Patented"or"Patent Pending"refer to design or utility patents Victaulic Company,and/or its affiliated entities,in the U.S.and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other countries. • 10.03 1539 Rev N Updated 09/2017 ®2017 Victaulic Company.All rights reserved. victaulic.com 4 ✓ctaulic C.I. THREADED FITTINGS STAR`TIPEPRODUCTS a 0 41> LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 Cast iron threaded fittings are UL,ULC listed and factory mutual approved for 300 psi service. Gray iron per ASTM A126 class B. Dimensions conform to ANSI B16.4 class 125 except plugs conform toASME B16.14.Threads are NPT per ANSI/ASME B1.20.1. - • ` i i �; I 1 I A .1 j 1 L " CAST IRON STRAIGHT TEE CAST IRON 90 DEGREE ELBOW NOMINAL ITEM MAX. DIMENSIONS WEIGHT NOMINAL ITEM MAX. DIMENSIONS WEIGHT SIZE CODE WORKING EACH SIZE CODE WORKING EACH (INCH) # P.S.I. A B PIECE (INCH) # P.S.I. A B PIECE 1 CT333 300 1.50 1.50 1.21 1 CB90033 300 1.50 1.50 0.95 11/4 CT444 300 1.75 1.75 1.87 1 1/4 CB90044 300 1.75 1.75 1.34 1 1/2 CT555 300 1.94 1.94 2.51 11/2 CB90055 300 1.94 1.94 1.80 2 CT666 300 2.25 2.25 3.96 2 CB90066 300 2.25 2.25 2.90 21/2 CT777 300 2.70 2.70 6.45 21/2 C890077 300 2.70 2.70 4.75 l • 4 I lx, , L CAST IRON RED. COUPLING NOMINAL ITEM MAX. DIMENSION WEIGHT CAST IRON 45 DEGREE ELBOW SIZE CODE WORKING EACH (INCH) # P.S.I. A PIECE NOMINAL ITEM MAX. DIMENSIONS WEIGHT 1X1/2 CRC031 300 1.7D 0.62 SIZE CODE WORKING EACH 1X3/4 CRC032 300 1.70 0.80 (INCH) # P.S.I. A B PIECE r, 1 CB45033 300 1.12 1.12 0.84 1 1/4 C B45044 300 1.29 1.29 1.40 1 1/2 C B45055 300 1.43 1.43 1.80 4 7.----- 2 CB45066 300 1.68 1.68 2.79 I. CAST IRON RED. 90 DEG. ELBOW NOMINAL ITEM MAX. DIMENSIONS WEIGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A B PIECE I I 1X1/2 CB90031 300 1.26 1.36 0.64 1X3/4 CB90032 300 1.37 1.45 0.87 CAST IRON PLUGS 11/4X1/2 C690041 300 1.34 1.53 0.96 NOMINAL ITEM MAX. DIMENSION WEIGHT 11/4X3/4 CB90042 300 1.45 1.62 1.13 1 1/4X1 CB90043 300 1.58 1.67 1.16 SIZE CODE WORKING EACH 1 1/2x1 1/2 CB90051 300 1.41 1.66 1.17 (INCH) # P.S.I. A PIECE 1 1/2x3/4 CB90052 300 1.52 1.75 1.28 1/2 CPL001 300 0.94 0.10 1 1/2X1 C890053 300 1.65 1.80 1.51 3/4 CPL002 300 1.07 0.17 1 1/2X1 1/4 CB90054 300 1.82 1.88 1.62 1 CPL003 300 1.25 0.28 2X1/2 CB90061 300 1.49 1.88 2.00 11/4 CPL004 300 1.36 0.44 2X3/4 CB90062 300 1.60 1.97 2.05 11/2 CPL005 300 1.45 0.62 2X1 CB90063 300 1.73 2.02 2.10 2 CPL006 300 1.56 0.91 2X1 1/4 CB90064 300 1.90 2.10 2.30 2X1 1/2 CB90065 300 2.02 2.16 2.60 Page 19 C.I. THREADED FITTINGS STAR®PIPE PRODUCTS 0 U L LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 CAST IRON CROSS r ( NOMINAL ITEM MAX. DIMENSIONS WBGHT ( SIZE CODE WORKING EACH (INCH) # P.S.I. A B PIECE 1 CX033 300 1.50 1.50 1.54 f, _ r- 1 1/4 CX044 300 1.75 1.75 2.40 t._._�� 1 1 1/2 CX055 300 1.94 1.94 3.10 2 CX066 300 2.25 2.25 4.00 1 1/4X1 CX043 300 1.58 1.67 2.05 1 1/2X1 CX053 300 1.65 1.80 2.40 2X1 CX063 300 1.73 2.02 2.75 CAST IRON REDUCING TEE NOMINAL ITEM MAX. DIMENSIONS WEIGHT . F.- SIZE CODE WORKING EACH (INCH) # P.S.I. A B C PIECE 1X1X1/2 CT331 300 1.26 1.26 1.36 0.95 1 X1 X3/4 CT332 300 1.37 1.37 1.45 1.10 ` 1 X1/2X1 CT313 300 1.50 1.36 1.50 1.08 1X3/4X1 CT323 300 1.50 1.45 1.50 1.18 1X1X1 1/4 CT334 300 1.67 1.67 1.58 1.52 1X1X1 1/2 CT335 300 1.80 1.80 1.65 1.73 1 1/4X1 X1/2 CT431 300 1.34 1.26 1.53 1.17 1 1/4X1 X3/4 CT432 300 1.45 1.37 1.62 1.38 1 1/4X1 X1 CT433 300 1.58 1.50 1.57 1.47 1 1/4X1 X1 1/4 CT434 300 1.75 1.67 1.75 1.80 1 1/4X1X1 1/2 CT435 300 1.88 1.80 1.82 2.05 1 1/4X1 1/4X1/2 CT441 300 1.34 1.34 1.53 1.37 1 1/4X1 1/4X3/4 CT442 300 1.45 1.45 1.62 1.54 1 1/4X1 1/4X1 CT443 300 1.58 1.58 1.67 1.65 1 1/4X1 1/4X1 1/2 CT445 300 1.88 1.88 ' 1.82 2.21 1 1/4X1 1/4X2 CT446 300 2.10 2.10 1.90 2.55 1 1/2X1 X1/2 CT531 300 1.41 1.34 1.66 1.41 1 1/2X1 X3/4 CT532 300 1.52 1.37 1.75 1.65 1 1/2X1 X1 CT533 300 1.65 1.50 1.80 1.65 1 1/2X1X1 1/4 CT534 300 1.82 1.67 1.88 2.00 1 1/2X1X1 1/2 CT535 300 1.94 1.80 1.94 2.30 1 1/2X1 1/4X1/2 CT541 300 1.41 1.34 1.66 1.58 1 1/2X1 1/4X3/4 CT542 300 1.52 1.45 1.75 1.72 1 1/2X1 1/4X1 CT543 300 1.65 1.58 1.80 1.85 1 1/2x1 1/4x1 1/4 CT544 300 1.82 1.75 1.88 2.22 1 1/2x1 1/4x1 1/2 CT545 300 1.94 1.88 1.94 2.45 1 1/2X1 1/4X2 CT546 300 2.16 2.10 2.02 2.80 1 1/2X1 1/2X1/2 CT551 300 1.41 1.41 1.66 1.76 1 1/2X1 1/2X3/4 CT552 300 1.52 1.52 1.75 1.87 1 1/2X1 1/2X1 CT553 300 1.65 1.65 1.80 1.94 1 1/2X1 1/2X1 1/4 CT554 300 1.82 1.82 1.88 2.29 1 1/2X1 1/2X2 CT556 300 2.16 2.16 2.02 3.28 2X1X2 CT636 300 2.25 2.02 2.25 3.40 2X1 1/4X2 CT646 300 2.25 2.10 , 2.25 , 2.80 2X1 1/2X1/2 CT651 300 1.49 1.41 1.88 2.09 2X1 1/2X3/4 CT652 300 1.60 1.52 1.97 2.40 2X1 1/2X1 CT653 300 1.73 1.65 2.02 2.54 2X1 1/2X1 1/4 CT654 300 1.90 1.82 2.10 2.85 2X11/2X11/2 CT655 300 1.49 1.41 1.88 2.24 2X1 1/2X2 CT656 300 2.25 2.16 2.25 3.75 2X2X1/2 CT661 300 1.49 1.49 1.88 2.60 2X2X3/4 CT662 300 1.60 1.60 1.97 2.71 2X2X1 CT663 300 1.73 1.73 2.02 2.97 2X2X1 1/4 CT664 300 1.90 1.90 2.10 3.32 2X2X1 1/2 CT665 300 2.02 2.02 2.16 3.72 2x2x2 1/2 CT667 300 2.60 2.60 2.39 5.10 Page 20 •••••••• COSCO Fire Protection i t+a P 3?'lt (tt°1tl ,q 1 I lit ',(fi !! ';{'i: Pipe Hangers COSCO Fire Protection Inc. 2501 SE Columbia Way, Suite 100 Vancouver,WA 98661 Phone:360-883-6383 Fax: 360-883-6390 Toll Free:800-983-6383 • CRDcY® Branch Line Restraint System hill f ''4 5 #/,tad P 4 bi fikfsY WkRd "eR.e3' ,. i.,.:::.iii, .s �re�r�eerFa«w.w�a � . � MfuSt4tf."CY�'f rc=%Brf2F.,is'lir4V UYx5 rm•- �yw...ww.wn*+' .... t., •;,.. , n p ..„,,,,{,. ,....,.,.... .....,.. . A ..., yrill[$ • 1`3411111) CMDDY <k .::>, W ERIED -- raditional methods for installing Patent Pending branch line restraints in fire . � ., sprinkler systems are cumbersome and time-consuming. Contractors often cut (and re-cut) threaded rod to precise measurements to restrain the sprinkler pipe with a loop hanger and surge restraint. Traditional methods also commonly require five or more partstk.nhw g .• per restraint. To avoid these labor-intensive methods, 44.4 . .4 ERICO has streamlined the process and developed the Branch Line Restraint System, part of the CADDY° line of hanging & bracing solutions for the fire Features protection market. Ideal for restraining • Complete restraint system is quick and easy to install 1" (25 mm) through 2" (50 mm) branch • Offers up to 80% time savings per branch line restraint lines, this innovative system is significantly • Eliminates need to cut threaded rod to exact dimensions faster and easier to install than current • Works with 3/8" and 1/2" (M10 and M12) rod methods. It attaches directly to steel • Restraint distances up to 40" (960 mm) from pipe to structure bar joists, I-beams or purlins, as well with 1/2" (M12) threaded rod as concrete and wood structures. The • All components install with a 5/16" (8 mm) socket drill driver hardware is installed with only one tool, • Meets requirements of NFPA® 13 section 9.3.6 a 5/16" (8 mm) socket drill driver, which provides significant labor savings and • Electro-zinc plated finish convenience. It features a simple, two- step installation process, allowing a time Branch Line Restraint Pipe Attachment savings up to 80% compared to other W I.-- methods. tifl F*,, RS- �I Unlike most solutions that only accept 3/8" threaded rod, the versatile Branch I o/ I Line Restraint System features a swivel attachment that can be rotated to accept j J 3/8" (M10) or 1/2" (M12) threaded rod. This allows greater restraint distances cULus Listed,FM Approved,and OSHPD pre-approved for light walled(SCH 7),SCH 10,and SCH 40 from the pipe to structure with 1/2" (M12) service pipes. threaded rod. •Accepts 3/8" (M10)or 1/2"(M12)threaded rod on either side of the service pipe The system meets the requirements •Quick grip clamp simplifies measuring and cutting of threaded rod of NFPA° 13, making it ideal for new •Works with rough-cut threaded rod and eliminates pipe-side deburring construction applications.The total •Shear-off head helps ensure correct torque and simplifies inspection system is cULus Listed and FM® Approved, Part Article Nominal OD„ RS": H„ w" L„ Pipe Size" and has been pre approved by the state Number Number (mm) (mm) (mm) (mm) (mm) (mm) of California (OSHPD OPA-2629-10). CSBBRPO100EG 404477 1 1.32 3/8,1/2 6.67 0.88 2.86 (25) (33.4) (M10,M12) (169.4) (22.2) (72.6) CSBBRPOIZSEG 404478 1-1/4 1.66 3/8,1/2 7.56 0.88 3.31 (32) (42.2) (M10,MU) (192.0) (22.2) (84.1) 44>IPC V� US CSBBRP0150EG 404479 1-1/21.90 3/8,1/2 8.20 0.88 3.63 111111 nvnnnvr LISTED (40) (48.3) (M10,M12) (208.4) (22.2) (92 2) h CSBBRP0200EG 404480 2 2.38 3/8, 1/2 9.45 0.88 4.25 (50) (60.3) (M10,M12) (240.0) (22.2) (108.0) ,„ www.erico.com Branch Line Restraint Structure Attachment to Steel ._._ } �. I SCxI III ! i caoor• __4- t C�1E1-.� d ;; sl \ /H 11011 , F RS w • Swivel connector accepts 3/8" (M10) or 1/2" (M12)threaded rod • Attaches to steel members with thickness from 0.105" (12 GA)to 0.5" (2.7 - 12.7 mm) with self-drilling/tapping screw Part Article RS" SCxL" H" W" L" Number Number (mm) (mm) (mm) (mm) (mm) CSBBRS1EG N/A 3/8,1/2 12-24x 1-1/4 1.11 1.06 1.59 (12-24 x 32) (28.2) (26.9) (40.4) CSBBRS1MEG 402239 (M10,M12) 12-24x 1-1/4 1.11 1.06 1.59 (12-24 x 32) (28.2) (26.9) (40.4) __.. _....._..... ill Branch Line Restraint Structure Attachment to Wood/Concrete401 #? t ' -SC.L --- 6 1.V°7; H �I 'iII r# • (. 13 4,. RS L l; W • Swivel connector accepts 3/8" (M10)or 1/2"(M12)threaded rod ; •Attaches to wood/concrete structure. , Pre-drill concrete with 3/16" (4.8 mm)drill bit(not included) Part Article RS" SCxL" H" W" L" Number Number (mm) (mm) (mm) (mm) (mm) NIP CSBBRS2EG N/A 3/8,1/2 1/4 x 1-3/4 1.11 1.06 1.59 i (6.4 x 44.5) (28.2) (26.9) (40.4) CSBBRS2MEG 402240 (M10,M12) 1/4 x 1-3/4 1.11 1.06 1.59 ,x:ry (6.4 x 44.5) (28.2) (26.9) (40.4) Branch Line Restraint Structure Attachment to Threaded Insert 11111.100"" SCxL - w !..-.. '" Utfie'F?S3Yi3 .6v.x*S 4 ttf"e.:i 3 h_ CADDY. ��I�1�r�° » ° ,'Y. H II' II d t 1 yk RS L W I j .,. i •Swivel connector accepts 3/8" (M10)or 1/2" (M12)threaded rod j •Attaches to concrete anchors or structural attachments with female threads •Also for use with Snake+e anchor(not included);part number 64015D Part Article RS" SC x L" H" W" L" Number Number (mm) (mm) (mm) (mm) (mm) CSBBRS3EG N/A 3/8, 1/2 3/8-16 x 3/4 1.11 1.06 1.59 C. (M10x19) (28.2) (26.9) (40.4) 3/8-16 x 3/4 1.11 1,06 1.59 3" CSBBRS3MEG 402241 (M10,M12) (M10 x 19) (28.2) (26.9) (40.4) Note:Branch line structural attachments are for restraint only and not for the hanging of fire sprinkler piping. www.erico.com ERICD Maximum Restraint Lengths Other products available for restraint lengths over 40" Continuous Threaded Rod (960 mm). Visit www.erico.com Least Radius for more fire protection and Rod Root of Gyration Maximum Unbraced Length(L)•in hanging & bracing solutions. Size(") Dia.(") r(") : L/r=100 L/r=200 L/r=300 I L/r=400* 3/8 0.300 0.075 7 14 22 30 "*4,^4 1/2 0.404 0.101 10 20 30 40 +� " e Rod Root Least Radius Maximum Unbraced Length(L)-mm of Gyration Size(mm) Dia.(mm) r(mm) L/r=100 L/r=200 L/r=300 I L/r=400* M10 7.94 1.99 198 397 595 794 M12 9.60 2.40 240 480 720 960 Reference: NFPA13,(2007) *Reference: NFPA13,(2010) som 'r .04 #; I • �rx FM is a registered certification mark of FM Approvals LLC,LTD. NFPA is a registered trademark of the National Fire Protection Association. Snake+is a registered trademark of Powers Fasteners,Inc. cULus is a registered certification mark of UL LLC. WARNING ERICO products shall be installed and used only as indicated in ERICO's product instruction sheets and training materials. Instruction sheets are available at www.erico.com and from your ERICO customer service representative. Improper installation,misuse,misapplication or other failure to completely follow ERICO's instructions and warnings may cause product malfunction,property damage,serious bodily injury and death. WARRANTY ERICO products are warranted to be free from defects in material and workmanship at the time of shipment.NO OTHER WARRANTY,WHETHER EXPRESS OR IMPLIED(INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE),SHALL EXIST IN CONNECTION WITH THE SALE OR USE OF ANY ERICO PRODUCTS.Claims for errors, shortages,defects or nonconformities ascertainable upon inspection must be made in writing within 5 days after Buyer's receipt of products.All other claims must be made in writing to ERICO within 6 months from the date of shipment or transport.Products claimed to be nonconforming or defective must,upon ERICO's prior written approval in accordance with its standard terms and procedures governing returns,promptly be returned to ERICO for inspection.Claims not made as provided above and within the applicable time period will be barred.ERICO shall in no event be responsible if the products have not been stored or used in accordance with its specifications and recommended procedures.ERICO will,at its option, either repair or replace nonconforming or defective products for which it is responsible or return the purchase price to the Buyer. THE FOREGOING STATES BUYER'S EXCLUSIVE REMEDY FOR ANY BREACH OF ERICO WARRANTY AND FOR ANY CLAIM,WHETHER SOUNDING IN CONTRACT,TORT OR NEGLIGENCE,FOR LOSS OR INJURY CAUSED BY THE SALE OR USE OF ANY PRODUCT. LIMITATION OF LIABILITY ERICO excludes all liability except such liability that is directly attributable to the willful or gross negligence of ERICO's employees.Should ERICO be held liable its liability shall in no event exceed the total purchase price under the contract.ERICO SHALL IN NO EVENT BE RESPONSIBLE FOR ANY LOSS OF BUSINESS OR PROFITS,DOWNTIME OR DELAY,LABOR,REPAIR OR MATERIAL COSTS OR ANY SIMILAR OR DISSIMILAR CONSEQUENTIAL LOSS OR DAMAGE INCURRED BY BUYER. Copyright 02012 ERICO International Corporation.All rights reserved. CADDY,CADWELD,CRITEC,ERICO,ERIFLEX,ERITECH,and LENTON are registered trademarks of ERICO International Corporation. ERICa M10955-WWEN DM1457LT11WWfN 101*10312 Beam Clamps B3034 - C-Clamp Size Range: 3/8"-16 thru 3/4"-10 rod G ` US Material: Cast Malleable Steel with hardened cup point set LISTED screw and jam nut Function: Recommended for hanging from steel beam 144> where flange thickness does not exceed 3/4"(19.0mm). APPROVED Features: May be used on top or bottom flange of the ---"'"\ > D beam. Beveled lip allows hanging from top flange where t clearance is limited. May be installed with the set screw in the up or down position. Offset design permits unlimited rod B adjustment by allowing the rod to be threaded completely Throat , y' through the clamp.The rear window design permits inspection Opening 6110. J of thread engagement. 3/4'(MA A �� (Rod Size) Approvals: Underwriters Laboratories Listed (cULus) and *- Hanger Rod Factory Mutual Engineering Approved (FM)for 3/8"-16 and 10 Not Included 1/2"-13 rod sizes. Conforms to Federal Specification WW-H-171 E &A-A-1192A, Type 23 and Manufacturers Set Screw and Locknut Included Standardization Society ANSI/MSS SP-69&SP-58, Type 19. 3/8"-16 is (cULus) Listed to support up to 4" (loomm) pipe with the set screw in the down position, up to 3"(75mm)pipe with the set screw in the up position. 1/2°-13 is(cULus) Listed to support up to 8"(200mm) pipe with the set screw in the down position, up to 6"(150mm) B3034-3/4" pipe with the set screw in the up position. shown. Factory Mutual Engineering Approved only with the setscrew a in the down position. Top Flange E R Finish: Plain. Contact customer service for alternative finishes Attachment Applications and materials. d Order By: Figure number, rod size and finish 0° Setscrew Torque: Per MSS SP-58 14.2.5 3/8" -16 set screws= 5 ft./lbs. (7 Nm) _ 1/2" -13 set screws = 11 ft./lbs. (15 Nm) Caution should be taken not to over-tighten set screws. B3034-5/e"and B3034-3/4'sizes Attach only as shown. C '� r --O C B Throat 411.1fr = .. Opening ""*„4„, ,gg ) g 3/4'(19.0) ti107 Bottom Flange A Attachment OP' = (Rod Size) Applications ;� = Hanger Rod W' i = Not Included Set Screw and Locknut Included Part Rod Set Screw Maximum Iron Approx. No. Size Size B C D Pipe Size Per UL Wt./100 A in. (mm) in. (mm) in. (mm) in. (mm) Lbs. (kg) B3034-3/8 3/8"-16 3/8"-16 x 11/2" 15/8" (41.3) 2" (50.8) 7/8" (19.0) 4" (100) 30 (13.6) B3034-1/2 1/2" 13 1/2"-13 x 11/2" 1t3/16" (46.0) 23/16" (55.6) 13/16" (30.2) 8" (200) 47 (21.3) B3034-5/8 5/8"-11 1/2"-13 x 2" 13/4" (44.5) 21/8" (54.0) 11/4' (31.7) -- -- 58 (26.3) B3034-3/4 3/4"-10 1/2"-13 x 2" 2" (50.8) 21/4" (57.2) 11/4" (31.7) -- -- 77 (35.0) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Fire Protection Solutions 13 Eaton Beam Clamps • TOLCOTM Fig.69 - Beam Clamp Retaining Strap Size Range: 3/8"-16 thru 3/4"-10 rod CON 4" (101.6mm)thru 16" (406.4mm) lengths LISTED Note: longer lengths are available consult factory Material: Pre-Galvanized Steel _ 7/16' ® — _" cm) Function: To offer more secure fastening of various types of 9/16, beam clamps to beam where danger of movement might be 114.3) expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies Fig.69-3/e-1/2 requirements of NFPA 13. Important Note: Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly.Therefore a locking mechanism of some kind, such as a hex nut for the Fig. 69 or Detail A the beveled locking slot of the Fig.69R will provide a more secure reliable installation. Approvals: Underwriters Laboratories Listed in the USA(UL) and Canada (cUL). Approved for use with any listed B-Line series or Tolco beam clamp. Finish: Pre-Galvanized D Order By: Figure number, length (L), and finish. Note: Minimum return on strap is 1" (25.4mm). Lengths over 16" (406mm)are not UL Listed. U CO CO it s � � Fig.69-5A-3A 1 ;, 1as Hole Dia.D For Use With Length Part No. in. Imm) B3033-3/8,B3034-3/a,B3031-3/a, 69-3/s-1/2-L see Detail A 65-3/8,65XT-3/s,66-3/8 Specify = j� B3033-1/2,B3034-1/2,65-1/2,66-1/2 69-5/8-L 11/1s" (17.5) B3033-5/8,65-5/a,66-5/8 Specify 69-3/4-L 13/16" (20.6) B3033-3/4 Specify ) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Fire Protection Solutions 17 Eaton Pipe Hangers TOLCO Fig. 200 - "Trimline" Adjustable Band Hanger TOLCO Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining for Copper Tubing TOLCO Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated TOLCO Fig. 200S - "Trimline" Adjustable Band Hanger with Removable Nut (For sizes 1"thru 2") Size Range: t Fig 200 - 1/2" (15mm)thru 8" (200mm) pipe A C 0 US 11.41100. Overall Height LISTED APPROVED Material: Steel, Pre-Galvanized e Function: For fire sprinkler and other general piping purposes. Knurled Center of pipe to top of knurled hanger rod nut. swivel nut design permits hanger adjustment after installation. o Top of pipe to bottom of hanger rod nut. Features: • '/2" (15mm)thru 2" (50mm) sizes have flared edges for ease of Fig. s installation on all pipe types and protects CPVC plastic pipe from ,� ' Zoo-'I & abrasion. Captured knurled nut design (flared top)on 1"thru 2"sizes 200-'/° keep nut from separating with hanger. Hanger is easily installed around pipe. -r,f- l'44? '' . • '/2" (15mm), 3/4" (20mm), and 21/2" (65mm)thru 8" (200mm)) Spring i / tension on nut holds it securely in hanger before installation. Knurled nut is easily removed. & ,' • For 1/2" (15mm) and 3/4" (20mm)sizes with non-captured knurl nuts V, order Fig. 200S Approvals: Underwriters Laboratories listed eh" (15mm)thru 8" (200mm)) Fig. in the USA(UL) and Canada (cUL)for steel and CPVC plastic pipe and Fig. ( 200-2'hto200-8 Factory Mutual Engineering Approved(FM) (3/4" (20mm) thru 8" (200mm)). ��z Conforms to Federal Specifications WW-H-171 E&A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, Type 10. Maximum Temperature: 650°F (343°C) VIP w Finish: Pre-Galvanized. Stainless Steel r ,:Y op ,drtn/ materials will be supplied with (2) hex nuts 'm.• ,„ 1',. t. in place of a knurl nut. rn c { Order By: Part number and pipe size .: (..). 1 t ** Note: For metric hanger rod sizes add the metric rod size to the figure number. ' Example: 200M8-172 or 200M10-11/2 Fig.200C Fig.200F Fig.200 Fig.200&Fig.200S t M8 rod size is not UL Listed or FM Approved 2000-11/2 shown 200E-1'/2 shown shown with captured nut shown with 1"thru 2"sizes only non-captured nut Pipe Size Rod Size A B D Max.Rec.Load Approx.Wt./100 Part No.** in. (mm) in. mm** in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kg) 200-'f2 1/2 (15) 3/8"-16 M8t or M10 33/4" (79.4) 25/8" (66.7) 111/32" (34.1) 400 (1.78) 11 (5.0) 200-3/4 3/4" (20) 3/e"-16 M81 or M10 31/8" (79.4) 21/2' (63.5) 1'/1s" (27.0) 400 (1.78) 11 (5.0) 200-1 1" (25) 3/e"-16 M81 or M10 33/e" (85.7) 25/8" (66.7) 11/8" (28.6) 400 (1.78) 12 (5.5) 200-1'/4 1'/4" (32) 3/8"-16 M81 or M10 33/4" (94.0) 27/s" (73.0) 15/32' (29.3) 400 (1.78) 13 (5.9) 200-1'/2 11/2" (40) 3/8-16 Mt8 or M10 37/8" (98.4) 2'/s" (73.0) 13/1s" (30.2) 400 (1.78) 14 (6.4) 200-2 2" (50) 3/8'"-16 M8t or M10 4'/2" (114.3) 39/50" (80.8) 13/,s" (30.2) 400 (1.78) 15 (6.9) 200-2'/2 2'/2" (65) 3/8-16 M10 55/8" (142.9) 41/8" (104.7) 1'/1s" (36.5) 600 (2.67) 27 (12.3) 200-3 3" (75) 3/t"-16 M10 57/8" (149.1) 4" (101.6) 13/4" (31.7) 600 (2.67) 29 (13.3) 200-3t/2 31/2" (90) 3/s"-16 M10 73/s" (187.3) 5'/4" (133.3) Vie (55.6) 600 (2.67) 34 (15.6) 200-4 4" (100) 3/s"-16 M10 73/8' (187.3) 5" (127.0) 13/8" (34.9) 1000 (4.45) 35 (16.0) 200-5 5" (125) 1/2' 13 M12 9'/8" (231.8) 61/4" (158.7) 311/32" (84.9) 1250 (5.56) 66 (30.2) 200-6 6" (150) 3/4"-13 M12 103/4" (257.2) 63/4 (171.4) 21/32' (56.3) 1250 (5.56) 73 (33.4) 200-8 8" (200) 1/2"-13 M12 131/8" (333.4) 83/4" (222.2) 37/32' (81.7) 1250 (5.56) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Fire Protection Solutions 23 Eaton