Loading...
Plans CD V ED „ SCOPE OF WORK: SYSTEM RATING TO INSTALL A ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM AT THE OWNER RESIDENCE GOVERNING CODES JUN 1 ,t 2021 LOCATED AT 12066 SW TURNAGAIN DRIVE TIGARD, OR 97224 2017 OREGON RESIDENTIAL SPECIALTY CODE 11.1 KWDC W 8 THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY 2019 OREGON FIRE CODE 8.85 KWAC CITY© TIGARC 1-o GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. 3UILDING DMSICEN i 5 N2017 OREGON ELECTRICAL SPECIALTY CODE DTHE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES F° N LIABILITY 2019 OREGON STRUCTURAL SPECIALTY CODE SHEET INDEX C� ; o " N ( EQUIPMENT SUMMARY The City of Tigard and its PV-0 COVER PAGE O•z PV-1 SITE PLAN w a 30 SILFAB SIL-370 BK MODULES employees shall not be Approved plans PV-2 ROOF PLAN&MODULES o w 30 ENPHASE 107 PLUS-72-2-US MICROINVERTERS responsible for discrepancies PV-2A STRING LAYOUT&BOM a z a which may appear herein. 5 haU be on fob S{=� PV-3 STRUCTURAL&ATTACHMENT DETAIL M GENERAL NOTES: WIRING AND CONDUIT NOTES: PV-4 ELECTRICAL LINE DIAGRAM&CALCS. • THESE CONSTRUCTION DOCUMENTS HAVE BEEN BASED ON FIELD INSPECTIONS AND • ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS PV-4A SPECIFICATIONS REVISIONS OTHER INFORMATION AVAILABLE AT THE TIME.ACTUAL FIELD CONDITIONS MAY REQUIRE PURPOSE AND APPROVED FOR THE SITE APPLICATIONS PV-5 SIGNAGE DESCRIPTION DATE REV MODIFICATIONS IN CONSTRUCTION DETAILS. • ALL PV CABLES AND HOMERUN WIRES BE#10AWG `USE-2, PV PV-6+ EQUIPMENT SPECIFICATIONS • ARCHITECT HAS NOT BEEN RETAINED TO SUPERVISE ANY CONSTRUCTION OR WIRE, OR PROPRIETARY SOLAR CABLING SPECIFIED BY MFR, INSTALLATION OF ANY EQUIPMENT AT SITE. OR EQUIVALENT; ROUTED TO SOURCE CIRCUIT COMBINER • CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, EQUIPMENT, TOOLS, OBTAINS ALL BOXES AS REQUIRED 1 PERMITS, LICENSES AND PAY ALL REQUIRED FEES AND COMPLETE INSTALLATION. • ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED 'PROJECT SITE -,,.,.i,, ., . , • THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE PROPER INSTALLATION AND ACCORDING TO NEC 690.8(A)(1)&(B)(1)], [NEC 240] [NEC COMPLETION OF THE WORK WITH APPROVED MATERIALS. 690.7] FOR MULTIPLE CONDUCTORS 'i • CONTRACTOR SHALL OBTAIN BULDING PERMIT. NO WORK TO START UNLESS BUILDING • ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT PERMIT IS PROPERLY DISPLAYED. SHALL BE DERATED ACCORDING TO [NEC TABLE 310.15 + ' l Signature with Seal • ALL WORKMANSHIP AND MATERIALS SHALL BE OF FIRST QUALITY AND IN COMPLIANCE (B)(2)(C)] BLACK ONLY** f i WITH THE REQUIREMENTS OF THE OR BUILDING CODE,THE DEPARTMENT OF • EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90°C I ENVIRONMENTAL PROTECTION AND ALL PERTINENT AGENCIES. RATED, WET AND UV RESISTANT,AND UL LISTED RATED FOR • IT IS ESSENTIAL THAT ALL WORK PROCEED WITH THE MAXIMUM COOPERATION OF ALL 600V, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT • , PARTIES AND WITH MINIMUM INTERFERENCE TO THE OCCUPANTS WITHIN THE BUILDING. WIRE FROM SHARP EDGES THE OWNER'S DIRECTIONS IN THIS REGARD SHALL BE FULLY COMPLIED WITH. • PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED . ' I • • THE CONTRACTOR SHALL PERFORM THE WORK IN STRICT CONFORMANCE WITH THE THHN/THWN-2 INSULATED, 90°C RATED,WET AND UV . • A • • DATE:06/05/2021 LOCAL LAWS, REGULATIONS AND THE NATIONAL ELECTRIC CODE. RESISTANT, RATED FOR 600V PER NEC 2008 OR 1000V PER PROJECT NAME&ADDRESS • THE CONTRACTOR SHALL OBTAIN ALL PERMITS,APPROVALS,AFFIDAVITS, NEC 2011 s ' CERTIFICATIONS, ETC.AND PAY ALL FEES AS REQUIRED BY THE LOCAL AUTHORITIES. • 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH ELECTRICAL NOTES: THE HIGHER VOLTAGE TO GROUND MARKED ORANGE OR THE EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE IDENTIFIED BY OTHER EFFECTIVE MEANS rL __ ... Lit • INSTALLED ONLY BY QUALIFIED PEOPLE.A QUALIFIED PERSON IS ONE WHO HAS SKILLS • ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCEL • > N AND KNOWLEDGE RELATED TO THE CONSTRUCTION AND OPERATION OF THE CIRCUIT PROTECTION . . _t Ci LC) ELECTRICAL EQUIPMENT AND INSTALLATIONS AND HAS RECIEVED SAFETY TRAINING TO • VOLTAGE DROP LIMITED TC)2%. H N I` RECOGNIZE AND AVOID THE HAZARDS INVOLVED. (NEC 690.4(E)AND 705.6) • NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE PV-0 HOUSE PHOTO SCALE:NTS LULU Z C J • LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY COLOR CODED AS FOLLOWS: DC POSITIVE- RED(OR MARKED f/ U Ur 0) CV SOLAR PHOTOVOLTAIC INSTALLATION. FOR A LINE SIDE TAP CONNECTION, UTILITY RED), DC NEGATIVE-GREY(OR MARKED GREY) z < 1Y CV NEEDS TO BE NOTIFIED WELL IN ADVANCE TO COORDINATE BUILDING ELECTRICAL SHUT • POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLOR Q LLI Z O N.— - OFF. CODED: DC POSITIVE GREY(OR MARKED GREY), DC —, 0 [ SITE • NEW CONDUIT ROUTING SHOWN IS ESSENTIALLY SCHEMATIC. SUBCONTRACTOR SHALL NEGATIVE- BLACK(OR MARKED BLACK) PROJECTj E ICJ et LAY OUT RUNS TO SUIT FIELD CONDITIONS AND THE COORDINATION REQUIREMENTS OF • AC CONDUCTORS>4AWG COLOR CODED OR MARKED: PHASE I w � < 0 OTHER TRADES. A OR L1-BLACK, PHASE B OR L2-RED, PHASE C OR L3-BLUE, , • ARRAY WIRING SHOULD NOT BE READILY ACCESSIBLE EXCEPT TO QUALIFIED NEUTRAL WHITE/GRAY 1 .f t Gz}sc� ` F— _ scsv raw=s, PERSONNEL. VALIDITY OF PERMIT CD1 • ALL EXTERIOR CONDUIT, FITTINGS,AND BOXES SHALL BE WATERTIGHT AND APPROVED - FOR USE IN WET LOCATIONS. (NEC 314.15A). THE ISSUANCE OF A PERMIT • WIRING METHODS FOR PV SYSTEM CONDUCTORS AREN'T PERMITTED WITHIN 10 IN. OF BASED ON CONSTRUCTION OFFICE COPY THE ROOF DECKING OR SHEATHING EXCEPT WHERE LOCATED DIRECTLY BELOW THE DOCUMENTS AND OTHER OFFICE ] ROOF SURFACE THAT'S COVERED BY PV MODULES AND ASSOCIATED EQUIPMENT DATA SHALL NOT PREVENT ry 12066 SW Turnagain Dr, Tigard,OR 97224,USA SHEET NAME WIRING THE CODE OFFICIAL FROM CITE'OF TIGARDei• BACK-FED BREAKER MUST BE AT THE OPPOSITE END OF BUS BAR FROM THE MAIN REQUIRING THE CORRECTION '`A'} Cook Park COVER PAGE BREAKER OR MAIN LUG SUPPLYING CURRENT FROM THE UTILITIES. OF ERRORS. ORSC 105.4 REVIEWED FOR ODE COMPLIANC1 Kme City • ALL CONDUCTORS AND WIRE TIES EXPOSED TO SUNLIGHT ARE LISTED AS UV RESISTANT. Approved: [ 9 9 SHEET SIZE 3 • CONTRACTOR SHALL FOLLOW ALL ELECTRICAL EQUIPMENT LABELING REQUIREMENTS OTC: [ 1 Bridgeport Viilage ANSI B 1 IN NEC 690 AND IFC 2015 1 i • PV SOURCE, OUTPUT AND INVERTER CIRCUITS SHALL BE IDENTIFIED AT ALL POINTS OF Permit#: ( � d Z3Z Tualatin River 11 X 17 1 �� �� TERMINATION, CONNECTION,AND SPLICES. THE MEANS OF ID CAN BE SEPARATE COLOR Address: 1�kQ� �J� 0.� r inn, CODING, MARKING TAPE, TAGGING ETC. (NEC 690.4). 2 SHEET NUMBER • MEASURE THE LINE-TO-LINE AND LINE-TO-NEUTRAL VOLTAGE OF ALL SERVICE Suite#: Pv-o VICINITY MAP SCALE:NTS 1 ENTRANCE CONDUCTORS PROIR TO INSTALLING ANY SOLAR EQUIPMENT. THE $}; 7 , Date: L' Z( PV-0 VOLTAGES FOR THE 240VAC RATED. i 1 ,4,1.4�,..,,,,,,a,.,:. _,.,.a.-tea,.-.,,,:-�;-� ,.:: "S._,-.,-�.--. �.v,.--�-�-;ti -�.-.;-��w��-�- -��.��,,. SITE NOTES SW TURNAGAIN DRIVE _• THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITY ' INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 7i1 „ O • THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR — ti.1 v BUILDING ROOF VENTS. PROPERTY LINE c w H N • PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED — — w 3 ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION [NEC 110.26] 7 v�i o N _ N � F Z W Z WNW. I I W w a' (E)DRIVEWAY N- I d *Tip: 3o Lu I0 0 a Z a la c) M 6'_9" REVISIONS DESCRIPTION DATE REV I I (E)MAIN SERVICE PANEL --i I ROOF#1 (30)SILFAB SIL-370 BK MODULES Signature with Seal i I I 1 2-STORY HOUSE DATE:06/05/2021 NN PROJECT NAME&ADDRESS Eft I I "°' I 1 1 LO co I— Z CV N._ w w Q ti N (E)FENCE _I C.) o oC N I Qw Z0 � , 1 I ) O D o V/ 2,_8" } w , � f co � O Q Y co ~ 2 I I cNi 0 I I *-- �., SHEET NAME t SITE PLAN Ti J I �% 1 r. SHEET SIZE ,/,� a�� w ANSI B 40�► w ,x 11" X 17„ a \ _ SHEET NUMBER 55' l _ 1 PROPERTY LINE 1 PLOT PLAN WITH ROOF PLAN PV-1 SCALE: 1/16"=1'-0" - SW hARVEY'S AVE. r V p`, _I MODULE TYPE, DIMENSIONS&WEIGHT SW TU RNAGAI N DRIVE NUMBER OF MODULES: 30 MODULES I ARRAY AREA & ROOF AREA CALC'S at � (E) FRONT OF RESIDENCE ROOF o Ili y w ARRAY ROOF AREA MODULE TYPE: SILFAB SIL-370 BK 1 � ��, `l - ROOF #OF AREA AREA COVERED w o MODULE WEIGHT: 41.9 LBS MODULES (Sq.Ft.) (Sq.Ft.) BY ARRAY +- 3 m 23 MODULE DIMENSIONS: 70.67" X 39.98" = 19.62 SF (%) ° 0 N UNIT WEIGHT OF AREA: 2.13 PSF 4; L:-----Ici( I I I I I #1 30 571.72 3296.12 17 Q.Z re w Z m ll TOTAL ROOF AREA COVERED W w a v T BY ARRAY(%) 3296.12 17 w rn J 2 � 2 (E)UTILITY METER j (E) MAIN SERVICE PANEL _ * I - (N) FUSED AC DISCONNECT ROOF#1 ___7 REVISIONS (N) ENPHASE IQ COMBINER BOX I (30)SILFAB SIL-370 BK MODULES DESCRIPTION DATE REV I y � (30)ENPHASE IQ7 PLUS-72-2-US MICROINVERTERS (N)3/4" EMT CONDUIT(IN ATTIC) (N)SNAPNRACK UR-40 RAILS I • I ! � I 2"X4"ENGINEERED TRUSS @ 24"O.C. (54)SNAPNRACK ULTRA RAIL ATTACHMENT DESIGN SPECIFICATION I I @24"O.C.WITHIN 36"OF RIDGE/EDGE/HIP, I RISK CATEGORY: II I � 1 � @48"O.C. EVEWHERE ELSE CONSTRUCTION: SFD • Signature with seal ZONING: RESIDENTIAL ( I (N)JUNCTION BOX 750Max . SNOW LOAD (ASCE 7 10): 10 PSF 500M In ♦- F a :� EXPOSURE CATEGORY: B C. a,. .F N WIND SPEED (ASCE 7-10): 110 MPH W rvN j • I ROOF DESCRIPTION �� 1 DATE.06/05/2021 • I • PROJECT NAME&ADDRESS ENGINEERED ENGINEERED m m ~ I I ROOF ROOF ROOF TILT AZIMUTH TRUSS TRUSS MATERIAL Cn ROOF#01 SIZE SPACING m m TILT- g g #1 20" 90° 2"X4" 24"O.C. SHINGLE n n , Ili ' a ( AZIM.-90° 8 8 i 2 N LEGEND �- ♦ • a Lo U -JUNCTION BOX ® 1 TTT • _ z_ cV ~ n -IQ COMBINER BOX i WN (LU1 sTC N AC -FUSED AC DISCONNECT L. L 1— v V N MEI -MAIN SERVICE PANEL i I 1 E z a CC N n -UTILITY METER + i 1900.05 I < W 1 0 -VENT,ATTIC FAN(ROOF OBSTRUCTION) 2 T . ( Fes-- Q 0) • -ROOF ATTACHMENT I ( I tW O J. i Vertical Mounting Zone Horizon[al Mounting Zone /n _...__.. _CONDUIT I W — 7 et- -RAFTER • * 750 Max i (.0I"' L 500 M ON a. s^T Al - ' 6� �Or 0 -I SHEET NAME CD W ROOF PLAN & ` ,/ z, _ 2 MODULES j�V ANSI B -," 11" X17" j 1 1 ROOF PLAN & MODULES ii SHEET NUMBER (E) BACK. OF RESIDENCE 4' / 11'-4" / 7'-11"- - L- It PV-2 SCALE: 1/8"= 1-0 SW HARVEY'S AVE. 2'-4" PV-2 BILL OF MATERIALS SW TURNAGAIN DRIVE EQUIPMENT QTY DESCRIPTION CC o SOLAR PV MODULE 30 SILFAB SIL-370 BK (E) FRONT OF RESIDENCE Ui r INVERTER 30 ENPHASE IQ7 PLUS-72-2-US MICROINVERTERS ' ,.c w 0 o JUNCTION BOX 1 JUNCTION BOX, NEMA 3R, UL LISTED _ c)l N 22 COMBINER BOX 1 ENPHASE IQ COMBINER W/IQ ENVOY(X-IQ-AM1-240-3) o o ° o N O o" N 60A FUSED AC DISCONNECT, (2)50A FUSES, 240V, NEMA 3R, UL -\ Z Ill Z o! ¢ i AC DISCONNECT 1 � w w Z - LISTED C-5 C-6 t - , w, m ATTACHMENT 54 SNAPNRACK, UMBRELLA LAG,TYPE 3, 41N, SS 3 F, ', } 2 ATTACHMENT 54 SNAPNRACK, ULTRA FOOT FOR U FLASHING, SILVER/BLACK , , C-4 ATTACHMENT 54 SNAPNRACK, COMP FLASHING,91N X 121N, SILVER/BLACK ALUM 0 ENPHASE Q CABLE 31 ENPHASE Q CABLE 240V, (PER CONNECTOR) m— C-3 C-8 REVISIONS BRANCH TERMINATOR 3 BRANCH TERMINATOR DESCRIPTION DATE REV WATER TIGHT CAPS 1 WATER TIGHT CAPS RAILS 15 SNAPNRACK RAIL- 14 FEET, UR-40(168") C-9 BONDED SPLICE 12 SPLICE KIT3 CLAMP 64 MODULES CLAMPS(MID CLAMPS&END CLAMPS) C-10 GROUNDING LUG 2 GROUNDING LUG oo • - MODULE STRINGING - A-1 B-1 Signature with Seal A-2 B-2 A-3 B-3 NN -'I 71 A-4 B-4 DATE:06/05/2021 -7 T:l PROJECT NAME&ADDRESS mm cc)cn m m A-5 B-5 Dow 0 0 A-6 B-6 Lu E N A-7 B-7 F— 0 LC) F- Z N 1..... W W Q ti N A-8 B-8 Q O 0 rn N • < W z p N= A-9 B-9 0 o rn ( 1- I2 W A-10 13-10 Q u) F- Z Y co _ o 0_ N SHEET NAME STRING ALAYOUT & BOM ,./ _. SHEET SIZE t % ANSI B `���T 11" X 17" 1 ROOF PLAN WITH STRING LAYOUT & BOM SHEET NUMBER (E) PACK OF RESIDENCE PV-2A SCALE: 1/8"= 1'-0" SW hARVEY'S AVE. PV-2A y S ,A" n LIJ 3 N F_o SNAPNRACK UR-40 RAIL SP PN w/''� 0 RI r m PV MODULE re ~M _ (E) COMP. SHINGLEl.z 2IJJ o SEE (2/PV-3) FOR // ` 3 W W-I z - ENLARGED VIEW -'� ' a , , REVISIONS 141111V PSP e DESCRIPTION DATE REV M -� Signature with Seal LBW LBW LBW --7 LBW 1 STRUCTURAL DETAIL DATE:06/05/2021 PV-3 SCALE: NTS PROJECT NAME&ADDRESS W co E N H 0 � PV MODULE W W Q P. N ( U (.9CY) N Z Q N Q W O LL ti END CLAMP SNAPNRACK, ULTRA FOOT FOR U - D o 0) FLASHING, SILVER/BLACK = (n I- QSNAPNRACK,COMP FLASHING,91N I- Ct w 0X 121N, SILVER/BLACK ALUM QCO 1 Si004°Jiriel*OF1 ,,1 CO�VII SNAPNRACK,UMBRELLA LAG,TYPE 3,41N, SSrV SNAPNRACK UR-40 RAIL SHEET NAME STRUCTURAL& ATTACHMENT DETAIL 1. 1 G• SHEET SIZE UgS @ 2 ,p. /G�NEER .°�(� ' X 1 ANSI g�. 2 ATTACHMENT DETAIL (enlarged view) 2*6: 0� SHEET NUMBER PV-3 SCALE: NTS PV-3 #OF CURRENT-CARRYING TERM. INITIAL CONDUCTOR FINAL CONDUCTOR CONDUIT FILL TEMP.CORR. CONDUIT CONT. MAX. BASE DERATED VOLTAGE ID TYPICAL CONDUCTOR CONDUIT PARALLEL CONDUCTORS IN OCPD EGC TEMP. LENGTH LOCATION LOCATION CIRCUITS CONDUIT PERCENT FACTOR FILL FACTOR CURRENT CURRENT AMP. AMP. RATING DROP y o BARE Ii a) *k 1 3 ARRAY JUNCTION BOX 12 AWG 0 CABLE - - 1 2 N/A N/A 6 AWG COPPER 0.76 (54°C) N/A 12.1A 15.1A N/A N/A 90°C 40FT 0.47% a F o .0 W D N m 2 1 JUNCTION BOX COMBINER BOX 10 AWG THWN-2 COPPER MIN 0.75"Dia EMT 3 6 26.72% 20A 10 AWG COPPER 0.96 (32°C) 0.8 12.1A 15.1A 40A 30.7A 90°C 54FT 0.70% o�% _ N rn FUSED AC THWN-2, C) o ~O o N 3 1 COMBINER BOX 6 AWG THWN-2 COPPER MIN 0.75"Dia EMT 1 3 36.53% 50A 6 AWG 0.96 (32°C) 1 36.3A 45.4A 75A 72.0A 90°C 5FT 0.07% Lam z g E a S U DISCONNECT COPPER 4 1 FUSED AC MSP 6 AWG THWN-2 COPPER MIN 0.75"Dia EMT 1 3 36.53% N/A 6 AWG THWN-2, 0.96 (32°C) 1 36.3A 45.4A 75A 72.0A 90°C 5FT 0.07% 3 w DISCONNECT COPPER 0 0. 2_ U, Lo M REVISIONS BRANCH A DESCRIPTION DATE REV 10- SILFAB SIL-370 BK MODULES / / • • • // ENPHASE Q CABLE - N /� \ Signature with Seal m ❑ ❑ ❑ BRANCH B 10- SILFAB SIL-370 BK MODULES / / TO UTILITY GRID DATE:06/05/2021 1 PROJECT NAME&ADDRESS BI-DIRECTIONAL • • • POINT OF INTERCONNECTION UTILITY METER#33 284 904 1 LINE SIDE TAP I 1-PH,3-W, 120V/240V L1J 2 - - _ (E)MAIN BREAKER TO 20A/2P ENVOY AC DISCONNECT: HOUSE 240 V,200A/2P IE=\ \ \ 240V,60A FUSED N �ii. 10A/2P NEMA 3R, UL LISTED o LO 20a/2P F- Z CV ~ m 0 ❑ ❑ i ' (2)50A FUSES CV L/ -1.r-— (E)MAIN SERVICE W 0LLI Q ~ N BRANCH C L. 1 20A/2P PANEL,200A RATED, i z Q CC CV 10- SILFAB SIL-370 BK MODULES - ---- - --- 1-PH,3-W,240V < LU Z 0 -3 CIp N— / / 3 4 ›- 7 F- O. • • • • 600 V,NEMA JUNCTION Q II CD Z UL LISTED Y co I (N)ENPHASE IQ EXISTING GROUND N 0_ \ \ \ COMBINER BOX ELECTRODE CONDUCTOR (X-IQ-AM 1-240-3) CO ID 0 0 C k (30)ENPHASE IQ7 PLUS-72-2-US MICROINVERTERS - SHEET NAME f SERVICE INFO \ ELECTRICAL LINE & CALCS. UTILITY PROVIDER: PGE SHEET SIZE AHJ NAME: CITY OF TIGARD MAIN SERVICE VOLTAGE: 240V ANSI B MAIN PANEL BRAND: SIEMENS 11" X 17" MAIN SERVICE PANEL: 200A _ A i _. _ ___. _ MAIN CIRCUIT BREAKER RATING: 200A SHEET NUMBER 1 ELECTRICAL RICAL LINE DIAGRAM MAIN SERVICE LOCATION: WEST PV-4 PV-4 SCALE: NTS \ SERVICE FEED SOURCE: UNDERGROUND \ SOLAR MODULE SPECIFICATIONS Voltage rise in Q Cable from the Microinverters to the Junction Box Cr8 MANUFACTURER/ MODEL SILFAB SIL-370 BK For branch circuit #A of 10 IQ 7PLUS Micros, the voltage rise on the 240 VAC Q Cable is 0.47% ; W �N VMP 38.3 V For branch circuit #B of 10 IQ 7PLUS Micros, the voltage rise on the 240 VAC Q Cable is 0.47% C _ 0 2 , o �'o N � IMP 9.66 A For branch circuit #C of 10 IQ 7PLUS Micros, the voltage rise on the 240 VAC Q Cable is 0.47% IS.0 w o N VOC 45.0 V Voltage rise from the Junction Box to the IQ Combiner Box o w< - J ISC 10.29 A VRise = (amps/inverter x number of inverters) x (resistance in DM) x (2-way wire length in ft) a ° TEMP. COEFF. VOC -0.279%/°C M = (1 .21 amp x 10) x (0.00129 QM) x (54 ft x 2) PTC RATING 345.5 W = 12.1 amps x 0.00129 0/ft x 108 ft REVISIONS MODULE DIMENSION 70.67"(L) x 39.98"(W) = 1 .68 volts DESCRIPTION DATE REV PANEL WATTAGE 370 W %VRise = 1 .68 volts _ 240 volts = 0.70% INVERTER SPECIFICATION The voltage rise from the Junction Box to the IQ Combiner Box is 0.70% ENPHASE IQ7 Voltage rise from the IQ Combiner Box to AC Disconnect MANUFACTURER / MODEL PLUS-72-2-US[240V] MAX DC SHORT CIRCUIT CURRENT 15A VRise = (amps/inverter x number of inverters) x (resistance in Q/ft.) x (2-way wire length in ft.) Signature with Seal CONTINOUS OUTPUT CURRENT 1.21 A (240V) = (1 .21 amp x 30) x (0.000491 Q/ft) x (5 ft x 2) = 36.3 amps x 0.000491 QM x 10 ft = 0.17 volts AMBIENT TEMPERATURE SPECS %VRise = 0.17 volts = 240 volts = 0.07% RECORD LOW TEMP -5°C The voltage rise from the IQ Combiner Box to the AC Disconnect is 0.07% DATE.06/05/2021 AMBIENT TEMP (HIGH TEMP 2%) 32°C PROJECT NAME&ADDRESS CONDUIT HEIGHT 0.5" Voltage rise from the AC Disconnect to Main Service Panel ROOF TOP TEMP 90°C VRise = (amps/inverter x number of inverters) x (resistance in 0/ft.) x (2-way wire length in ft.) CONDUCTOR TEMPERATURE RATE 54°C = (1 .21 amp x 27) x (0.000491 Q/ft) x (5 ft. x 2) o CN MODULE TEMPERATURE COEFFICIENT OF VOC -0.279%/°C = 36.3 amps x 0.000491 Q/ft x 10 ft. w W z N N 0.17 volts N U 0 rn CV %VRise = 0.17 volts _ 240 volts = 0.07% Et z z PERCENT OF VALUES NUMBER OF CURRENT The voltage rise from the AC Disconnect to the Main Service Panel is 0.07% -) p c o r` CARRYING CONDUCTORS IN EMT I- W 0.80 4-6 Total system voltage rise all wire sections Q ct .' 0 Oz 0.70 7-9 0.47% + 0.70% + 0.07% + 0.07% = 1 .31% c�Oo 2 0.50 10-20 oN � SHEET NAME SPECIFICATIONS SHEET SIZE ANSI B 11" X17" SHEET NUMBER PV-4A 1 WARNING-Electric Shock Hazard 7 NOMINAL OPERATING AC VOLTAGE: 240V =.. NONo user serviceable parts inside NOMINAL OPERATING AC FREQUENCY: 60HZ ' o Contact authorized service provider for assistance MAXIMUM AC POWER: 8.85KW UJ a) IL71 3 F LABEL LOCATION: MAXIMUM AC CURRENT: 45.4A ;.cc w o N COMBINER BOX MAXIMUM OVERCURRENT PROTECTIVE _ ° N (PER CODE:NEC690.13.G.3&NEC 690.13.G.4) DEVICE FOR AC MODULE PROTECTION: 50A a z FO N N Q.Z Z W .9g N Z �k LABEL LOCATION: ix ce w w< rn .71 MAIN SERVICE PANEL 1 2 A SECTION:NEC690.52 a0 Z EL s' LABEL LOCAT THIS EQUIPMENT FED BY MULTIPLE REVISIONS UTILITY METTERR 8 WARNING (PER CODE:NEC 705.12(D)(4)) SOURCES. TOTAL RATING OF ALL DESCRIPTION DATE REV OVERCURRENT DEVICES EXCLUDING MAIN 3 PHOTOVOLTAIC SYSTEM AC DISCONNECT SUPPLY OVERCURRENT DEVICE SHALL NOT RATED AC OUTPUT CURRENT 36.3 AMPS EXCEED AMPACITY OF BUSBAR. LABEL LOCATION: NOMINAL OPERATING AC VOLTAGE 240 VOLTS MAIN SERVICE PANEL LABEL LOCATION: AC DISCONNECT 9 RAPID SHUTDOWN SWITCH Signature with Seal (PER CODE:NEC 690.54) FOR SOLAR PV SYSTEM 4 WARNING LABEL LOCATION: INVERTER OUTPUT CONNECTION DO NOT AC DISCONNECT (PER CODE:OESC 690.56(C)(3) RELOCATE THIS OVERCURRENT DEVICE [A RAPID SHUTDOWN SWITCH SHALL HAVE A LABEL LOCATED DATE:06/05/2021 ON OR NO MORE THAN 1 M(3FT)FROM THE SWITCH.] LABEL LOCATION: PROJECT NAME&ADDRESS MAIN SERVICE PANEL (PER CODE:NEC 705.12(D)(7)) [Not required if panelboard is rated not less than sum of ampere ratings of all overcurrent devices supplying it] W A WARNING I— 0d' TERMINALS ON THE LINE AND I— Z CV t 5 LOAD SIDES MAY BE ENERGIZED W W Q N IN THE OPEN POSITION lCe 0 0LABEL LOCATION: Et z < CC N COMBINER BOX,AC DISCONNECT&MAIN < Q ? Q N-SERVICE PANEL (PER CODE:NEC 690.13(B)) _ I— Q W 0 0. SOLAR PV SYSTEM EQUIPPED Q FZ - WITH RAPID SHUTDOWN Y CO I CL 6 TURN RAPID SHUTDOWN 0 SWITCH TO THE N "OFF"POSITION TO AcoL4°gRe c`s,,c` SHUT DOWN PV SYSTEM °V NE AND REDUCE SHOCK HAZARDMill IN THE ARRAY 111 LABEL PER NEC 690.56(C)-PROVIDE AT SUB PANEL OR SHEET NAME SERVICE PANEL FOR RAPID SHUTDOWN COMPLIANT SIGNAGE SYSTEM SHEET SIZE ADHESIVE FASTENED SIGNS: •THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT ANSI B WHERE IT IS INSTALLED. •WHERE REQUIRED ELSEWHERE IN THIS CODE,ALL FIELD 11" X 1 7" APPLIED LABELS,WARNINGS,AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4[NEC 110.21(B)FIELD MARKING]. I SHEET NUMBER •ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY I ERLY [IFCD605.11.1.3] HRED. L SIGNS SHALL BE WEATHER PR PV-5 Cr V1 0 0 U w u - w D o Electrical S.ecifications 51L-370 BK mono PERC MWTTechnolo: 3 to N- '3 �.�� Test Conditions STC NOCT 0C N rn `‘ O ... ..\ BC Series Module Power(Pmax) Wp 370 276.87 Q •--- ��xs Maximum power voltage(Vpmax) V 38.3 3591 Z Z w • __".� ._ __ -_. __., -__— . re X ¢ -tom) . W w J cn - -_.- �ti... :<-" Maximum power current(Ipmax) A 9.66 7.71 �_ ciC v Q7 J " CCpen circuit voltsg_e(Voc) V 45.0 42.19 ,YA--` w 7 Short circuit current{Isc) A 10.29 819 a z a I — _ a Module efficiency % 20.8 19.5 v, SOLAR Maximum system voltage(VDC) V 1000 �T v m -.._- __ ;.` (Early 2021) Se_nes fuse rating __._.._,__ A 20 Power Tolerance Wp Oto+10 REVISIONS Measurement conditions:STC 1000 W/m2.AM 1.5•Temperature 25°C•NOCT 800 W/ma•AM 1.5•Measurement uncertainty s 3% JUST TIER 1 0 •Sun simulator calibration reference modules from Fraunhofer Institute.Electrical characteristics may vary by 3596 and power by 0 to+10W. DESCRIPTION DATE REV BAA 25r _ IN- ONv[il BANKABLE Tem•erature Ratings SIL-370 BK mono PERC MWT Technology ARRA PAR i TIME ••«••• y�P�$ HIGH Temperature Coefficientlsc q_ +0.046%/°C 'IIRRNNTY „,c.,. ... — Temperature Coefficient Voc -0.279%/°C Temperature Coefficient Pmax -0.377%/°C NOCT(+2°C) . .__. 43.5°C HIGH EFFICIENCY INDUSTRY LEADING WARRANTY operating temperature 4o/+ss All our products include an industry Mechanical Pro.erties and Com•onents SIL-370 BK mono PERC MWT Technology PREMIUM leading 25-year product workmanship Module ht 19.0t0.2 k 4L9to4j and 30-year performance warranty. g _ g lbs MONO-PERC Dimensions(H x L x 0) 1795 mm x 990 mm x 38 mm 70.67 in x 39.98 in x 1.5 in Signature with Seal MAXIMUM ENERGY OUTPUT Maximum surface load(wind/snow)* 4000 Pa rear load!5400 Pa front load 83.5/112.8Ib/ft^2 PV MODULE Hail impact resistance o 25 mm at 83 km/h 0 1 in at 51.6 mph Silfab BC Series utilizes next generation 66 high efficiency back contact 66 high efficiency back contact Back Contact technology to reduce Cells mono-PERC c-Si cells mono-PERC c-Si cells production/manufacturing steps and Glass 3.2 mm high transmittance,tempered, 0.126 in high transmittance,tempered, Back Contact DSM anti-reflective coating DSM anti-reflective coating improve quality while maximizing power. Cables and connectors(refer to 1200 mm o 5.7 mm,MC4 from Staubli 47.24 in, 0 0.22 in,MC4 from Staubli Ideal for residential and commercial - Backsheet Multilayer,integrated insulation film and electrically conductive backsheet, Technology projects where maximum power density superior hydrolysis and UV resistance,fluorine-free PV backsheet is preferred. Frame Anodized Aluminum(Black) DATE:06/05/2021 Bypass diodes 3 diodes-30SQ045T(45V max DC blocking voltage,30A max forward rectified current) PROJECT NAME&ADDRESS C E 0.' NORTH AMERICAN QUALITY Silfab is the leading automated solar Junction Box UL 3730 certified,IP67 rated G Warranties Si4370 BK mono PERC MWTTechnoio a Module product workmanship warranty 25 years** module manufacturer in North America. (EC Fraunhofer 30 gears ---.• sE Utilizing premium quality materials and Linear power performance guarantee Z 97,1%end 1'r ear it 91.6%end 12"' ar1285.1%end 2S`" ear z 82.6%end 30r" ear n w strict quality control management to Certifications SIL-370 BK mono PERC MWT Technology t _ CO deliver the highest efficiency,premium ULCORDC1703***,UL1703***,CEClisted***,UL61215-1/-1-1/-2***,UL61730-1/-2***,IEC & W CNI c H U EB B quality PV modules 100%made in Product 61 21 5-1/-1-1/-2***.IEC61730-1/-2***,CSA C22.2#61730-1/-2***,!EC 62716 Ammonia g I- o LO .+re,a,o ,ssbn Instance to S+irab solo,Inc. 5 North America. Corrosion;IEC61701:2011 Salt Mist Corrosion Certifed,UL Fire Rating:Type 1 $ z N 1 Facto 15O9001:2015 1 _ _.. LLI LLI Q ti C\I St Modules Per Pallet 26 ��t1—s01 - cc O Ur c (N Hi Pallets Per Truck:34 N ' Modules Per Truck:884 ' r 1 y i S L.L Z < N *A Warning.Read the Safety and Installation Manual A i Q Li Z 0 PROVIDES MAXIMUM EFFICIENCY DOMESTIC PRODUCTION for mounting specifications and before handling, e I Q (` High-efficiency cells combined with a black conductive back- Silfab Solar manufactures PV modules in two automated installing and operating modules. t ri' i H sheet resulting in a maximum power rating of 370Wp. locations within North America.Our 500+North American **12 year extendable to 25 years subject to regis- .a 1 E S a I} (n 1 [ration and conditions outlined under'Warranty'at E Q 0 team is ready to help our partners win the hearts and minds www.silfabsoiar.com. W 35+YEARS OF SOLAR INNOVATION � o � f— � � of customers,providing customer service and product delivery ***Certification anticipated November 2020. g Z aeraging over 35+years of worldwide experience in the solar Erl that is direct,efficient and local. PAN files from 3rd e CO industry,Silfab is dedicated to superior manufacturing processes generatedparty performanceo data are available for download at. 7 3 (9 I and innovations such as Bifacial and Back Contact technologies SUPERIOR POWER wwwsilfabsolar.com/downloads. ' ; O LL to ensure our partners have the latest in solar innovation. Super power achieved through relocation of tabbing ribbon to = N BAA/ARRA COMPLIANT reduce shading on module front service and circuit resistance. 3 _ `— Silfab panels are designed and manufactured to meet Buy AESTHETICALLY PLEASING American Act Compliance.The US State Department,US Military Sleek aesthetics from black cells to black back-sheet without and FAA have all utilized Silfab panels in their solar installations. tabbing or bus-bar ribbons,ideal for residential applications. LIGHT AND DURABLE STABLE PERFORMANCE Silfab Solar inc. ts Engineered to accommodate high wind load conditions for test loads Enhanced life-time performance through reduced thermal z40Courtneypark Drive East _ asrsmmtzr."a _ I SHEET NAME Mississauga ON LST2Y3 Canada EQUIPMENT validated up to 4000Pa uplift.The light-weight frame is exclusively stresses and increased current flow paths. Tel 905-255-2501 Fax 905-696-0267 E Slftal �' ` SPECIFICATION designed for wide-ranging racking compatibility and durability. PID RESISTANT s«.a info@silfabsolar.com I wwwsilfabsolar.com S I,. IQUALITY MATTERS PID Resistant due to advanced cell technology and material ri SilfabSolarInc. 1 1a Total automation ensures strict quality controls during the entire selection.In accordance to IEC 62804-1. ®® 800 Cornwall Ave - 9BDn""l'�'� - SHEET SIZE manufacturing process at our ISO certified facilities. Bellingham WA 98225 USA Tel+1 360-569-4733 e ANSI B 11" X 17" SHEET NUMBER PV-6 V' I o 11J # Data Sheet Enphase IQ 7 and IQ 7+ Microinverters i 2 Enphase Microinverters 0 a �o N 5 INPUT DATA(DC) IQ7-b0-2-US IQ7PLUS 72 2-US t re W J rn U it AMER;C.r-�, _ .. �. .��.�.�_� _ � z Z w o � Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ z Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules i U _ v Maximum input DC voltage 48 V 60 V o w Peak power tracking voltage 27 V-37 V 27 V-45 V - a z d Operating range 16 V-48 V 16 V-60 V , co Min/Max start voltage 22 V/48 V 22 V/60 V Max DC short circuit current(module Ise) 15 A 15 A Enphase The high-powered smart grid-ready OvervoltageclassDCport II it REVISIONS DC port backfeed current 0 A O A DESCRIPTION DATE REV Enphase IQ 7 Micror"and Enphase IQ 7+Micror" PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; IQ7 and 7+ dramatically simplify the installation process while AC side protection requires max 20A per branch circuit I achieving the highest system efficiency- OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Mlcreinverter Mi c ro i nve rte rs Peak output power 250 VA 295 VA Part of the Enphase IQ System,the IQ 7 and Maximum continuous output power 240 VA 290 VA IQ 7+Microinverters integrate with the Enphase Nominal(L-L)voltage/range' 240 V/ 208 V/ 240 V/ 208 V/ g p 211-264 V 183-229V 211-264 V 183-229 V IQ Envoy',Enphase IQ Battery-,and the Enphase Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Nominal frequency 60 Hz 60 Hz Enlighten" monitoring and analysis software. Extended frequency range 47-68 Hz 47-68 Hz Signature with Seal IQ Series Microinverters extend the reliability AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11(208 VAC) standards set forth by previous generations and Overvoltage class AC port III Ill undergo over a million hours of power-on testing, AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 enabling Enphase to provide an industry-leading Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading 0.85 laggin g Warranty of up to 25 years. Peak efficiency @208 V e 7 7ncy 97.6% 9 6% 9 5o V 97 DATE:06/05/2021 CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% PROJECT NAME&ADDRESS MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Easy to Install Connector type(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) W Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) • Lightweight and simple Weight 1.08 kg(2.38 Ibs) cc N • Faster installation with improved,lighter two-wire cabling Cooling Natural convection-No fans Q X)— • Built-in rapid shutdown compliant(NEC 2014&2017) Approved for wet locations Yes I- Z CV ~ fin Pollution degree PD3 W W Q (NI Productive and Reliable Enclosure Class II double insulated,corrosion resistant polymeric enclosure f U 0 0) N rNv — _ Environmental category/UV exposure rating NEMA Type 6/outdoor L L Z < • Optimized for high powered 60-cell and 72-cell*modules FEATURES < W Z O N ��S • More than a million hours of testing Communication Power Line Communication(PLC) 0 D 0 CD ' • Class it double-insulated enclosure Monitoring Enlighten Manager and MyEnlighten monitoring options, _ (n I— Both options require installation of an Enphase IQ Envoy. W UL listed Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break I 0 e"P"ase -' disconnect required by NEC 690. Q Z IQ 7 Smart Grid Ready Compliance CA Rule 21(UL 1741-SA) Y o CO UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 • Com lies with advancedgrid support,ort,voltage and El— tip � �� P PPThis product is UL Listed as PV Rapid Shut Down Equipment and conforms with NECNEC-2014 and r— frequency ride-through requirements NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC • Remotely updates to respond to changing and DC conductors,when installed according manufacturer's instructions. grid requirements • Configurable for varying grid profiles • Meets CA Rule 21(UL 1741-SA) SHEET NAME T 0 *The IQ 7+Micro is required to support 72-cell modules. EQUIPMEN 1 1.No enforced DC/AC ratio.See the compatibility calculator at httos'//enphase-corn/en-us/support/module-compatibility. SPECIFICATION 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. cexnnr° SHEET SIZE ENPHASE. Enphaseofferings, enphase.com '' ENPHASE. To learn more about visit To learn more about Enphase offerings,visit enphase.com t.d %./ ANSI B 0 2019 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. 2019-3-26 1 1 n X 1 7" SHEET NUMBER PV-7 CC N 0 IW o �,r 41 Tt L � � fw�rn w � torn 2 r-- Data Sheet Enphase IQ Combiner 3 0 a o N Enphase Networking MODEL NUMBER 2 O m N —._._.....___.. z w z -- gt IQ Combiner 3 IQ Combiner 3 with Enphase IQ Envoy'"printed circuit board for integrated revenue grade PV W w< r; U X-IQ-AM1-240-3 production metering(ANSI C12.20+1-0 5%)and optional*consumption monitoring(+/-2.5%). 3 w>1- ElJ ACCESSORIES and REPLACEMENT PARTS(not included,order separately) a d z Enphase Mobile Connect'" CELLMODEM-03(4G/12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 M CELLMODEM-01(3G/5-year data plan) microinverters.(Available in the US.Canada,Mexico,Puerto Rico,and the US Virgin Islands, CELLMODEM-M1(4G based LIE-M/S-year data plan) where there is adequate cellular service in the installation area.) Consumption Monitoring*CT Split core current transformers enable whole home consumption metering(+/-2.5%). REVISIONS Enphase The Enphase IQ Combiner 3r" with Enphase CT-200-SPLIT DESCRIPTION DATE REV *Consumption monitoring is regwred for Enphase Storage Systems IQ Envoy- consolidates interconnection Wireless USB adapter Installed at the IQ Envoy.For communications with Enphase Encharge storage and Enphase IQ Combiner 3 COMMS-KIT-01 Enpower-smart switch.Includes USB cable for connection to IQ Envoy or Enphase IQ Combiner"' equipment into a single enclosure and and allows redundant wireless communication with Encharge and Enpower. Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240.BR250,and BR260 circuit breakers (X-IQ-AM1-240-3) streamlines PV and storage installations by BRK-10A-2-240 Circuit breaker,2 pole,10A,Eaton BR210 BRK-15A-2-240 Circuit breaker,2 pole,15A,Eaton BR215 BRK-20A-2P-240 Circuit breaker,2 pole,20A,Eaton BR220 providing a consistent,pre-wired solution for EPLC-01 Power line carrier(communication bridge pair),quantity-one pair residential applications. It offers up to four XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3(required for EPLC-01) 2-pole input circuits and Eaton BR series XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board(PCB)for Combiner 3 Signature with Seal busbar assembly ELECTRICAL SPECIFICATIONS _. Rating Continuous duty System voltage 120/240 VAC,60 Hz Eaton BR series busbar rating 125 A Max.continuous current rating(output to grid) 65 A Max.fuse/circuit rating(output) 90 A DATE:06/05/2021 Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DC)breakers only(not included) Smart Max.continuous current rating(input from PV) 64 A PROJECT NAME&ADDRESS •t ' Includes IQ Envoy for communication Max.total branch circuit breaker rating(input) 80A of distributed generation/90A with IQ Envoy breaker included and control Production Metering CT 200 A solid core pre-installed and wired to IQ Envoy • Flexible networking supports Wi-Fi, MECHANICAL DATA >i I EEtphernet,or cellular Di ent ions(WxHxD) __H,__ T__ 49.5 x 37 5 x 16-8 cm(19 5"'x 14.75-x 6-63").Height is 21_06"(53.5 cm with mounting brackets)- > CO ?b Optional AC receptacle available for PLC 7.5 kg(16.5Ibs) Q CN r 1 - ` ° bridgeAmbient temperature range -40°C to+46°C(-40°to 115°F) • Provides production metering and optional f— Z CV r Cooling Natural convection,plus heat shield LL.I W N (NIT, €.� consumption monitoring Q f� r r ry Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction Q U 0 CA N a Q N Wire sizes • 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors Z < t Simple • 60 A breaker branch input. 4 to 1/0 AWG copper conductors < W Z 0 N— i. ti • Main lug combined output 10 to 2/0 AWG copper conductors I` $ (j v1 • Reduced size from previous combiner • Neutral and ground 14 to 1/0 copper conductors - D C) I Always follow local code requirements for conductor sizing. Cl) I"— —3...p $ f-i) • Centered mounting brackets support single Altitude To 2000 meters(6,560 feet) _ I I Q ^" stud mountingNN INTERNET CONNECTION OPTIONS ~ L� (I) • Supports back and side conduit entry Q O r=, •, Integrated Wi-Fi 802-11b/g/n Y CO • Up to four 2-pole branch circuits for 240 VAC CS) Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable (not included) p plug-in breakers(not included) CV a '.•.,, • 80 A total PV or storage branch circuits Cellular Optional,CELLMODEM-01(3G)or CELLMODEM-03(4G)or CELLMODEM-M1(4G based LTE-M) (not included) COMPLIANCE Reliable Compliance,Combiner UL 1741, CAN/CSA C22.2 No.107.1,47 CFR,Part 15,Class B,ICES 003 Production metering.ANSI C12.20 accuracy class 0.5(PV production) • Durable NRTL-certified NEMA type Compliance,IQ Envoy UL 60601-1/CANCSA 22.2 No.61010-1 3R enclosure SHEET NAME (111) • Five-year limited warranty EQUIPMENT • UL listed To learn more about Enphase offerings,visit enehase.com SPECIFICATION LISTED ©2018 Enphase Energy.Ail rights reserved Enphase,the Enphase logo,IQ Combiner 3,and other trademarks or service names are the SHEET SIZE To learn more about Enphase offerings,visit enphase,com N." EN P HAS E. 20tra1de 1t1 rkkss of Enphase Energy,Inc-04 , ,-` EN PHAS E. ANSI B 11" X17" SHEET NUMBER PV-7A X Y o U.10 Tk 17) �a DESCRIPTION. DRAWN BY: DESCRIPTION: I DRAWN BY: — L rn 2 1- SNAPNRACK, ULTRA RAIL COMP KIT mwatkins SNAPNRACK, ULTRA RAIL COMP KIT mwatkins Sina3Nr,q, CkcZ z w o U. 2 REVISION: 1 REVISION: 9:1, re cc w W 7, PART NUMBER(S): 1 PART NUMBER(S): Llt ) p >w 595 MARKET STREET.29TH FLOOR•SAN FRANCISCO.CA 96/05 USA PHONE(11 51 880 8900•FPJ((4,51880-9902 I g 595 MARKET STREET.29TH FLOOR•SAN FRANCSCO.CA 96105 USA PRONE(415)580.0900.FAX(115)5 ISCO J a >d C Z SEE BELOW BSEE BELOW N N nmo aau w S[ n _Cwrmco vnm6nconaEn.or su�n.nswTH tic UMBRELLA L FOOT PROPERTIES REVISIONS SKU DESCRIPTION DESCRIPTION DATE REV 242-01219 ULTRA RAIL UMBRELLA L FOOT, SILVER s 242-01220 ULTRA RAIL UMBRELLA L FOOT, BLACK '-�-1.37 N. > 38 — 30 �> v I 1.00 �, SLOT ® ft 1 Signature with Seal Ni. _ 1 '0000',,,,i'lr J 1.50 0 1 3.25 2.78 yor r�• 1.78 -•--1.62 I1 DATE:06/05/2021 1.80--{ 1.50 -I PROJECT NAME 5 ADDRESS COMP FLASHING PROPERTIESk)00 \ , 4[..t':-.--4' SKU DESCRIPTION �� 232-01375 COMP FLASHING, 9" X 12", BLACK ALUM W � 232-01376 COMP FLASHING, 9" X 12", SILVER ALUM �'' E CV T 1-- tiG� , - - -® " -L� N �, I in w Q rc.1 (�I c Cr ( QwZ Q Q ,I 30 61.00 S nV © i� = w cc 6.75 ® I r., ,i1,1_ 11.75 J co _ o PARTS LIST 1 0 0 CV 4.20 I ITEM QTY PART NUMBER DESCRIPTION 105° 1 1 242-92266 'SNAPNRACK, UMBRELLA LAG, TYPE 3, 4IN, SS l 2 1 242-01219, 242-01220 SNAPNRACK, ULTRA FOOT FOR U FLASHING, SILVER/ BLACK y 3 1 232-01375, 232-01376 SNAPNRACK,COMP FLASHING, 9IN X 12IN, SILVER/ BLACK ALUM 4 I MATERIALS: 6000 SERIES ALUMINUM, STAINLESS STEEL, RUBBER 0.35 SHEET NAME DESIGN LOAD (LBS): 802 UP, 1333 DOWN, 356 SIDE 3.25 EQUIPMENT ULTIMATE LOAD (LBS): 2005 UP, 4000 DOWN, 1070 SIDE SPECIFICATION SHEET SIZE TORQUE SPECIFICATION: 12 LB-FT CERTIFICATION: UL 2703, FILE E359313; WIND-DRIVEN RAIN TEST FROM UL SUBJECT 2582 ".• 8.75 — .45—.- H ANSI B WEIGHT (LBS): 0.80 ALL DIMENSIONS IN INCHES 1 1" X 17" SHEET NUMBER PV-8 DESCRIPTION: DRAWN BY: CC-00 SNAPNRACK, UR-40 RAIL i mwatkins S(ni 1\\rack- w� Tk W TN REVISION: 0 1 �H'as N 2 PART NUMBER(S): o �r o N B 595 MARKET STREET,29TH FLOOR•SAN FRANOISCO.CA 94105 USA '� Z W z W it PHONE(415)580-6900•FAX(415)580-6802 Ct• M d'Q (0 232-02449, 232-02450, 232-02451 w w THE NFORMATION N THIS CRANING IS CONFIDENTIAL AND PROPRIETARY.ANY LLI REPRODU.C.TION.DISCLOSURE.CR USE THEREOF IS PROMO.WITHOUT THE ^ - NINTTEN CONSENT OF SUNRUN SOUTH LLC. d O Za In CO REVISIONS UR-40 RAIL DESCRIPTION DATE REV PROPERTIES SKU FINISH 232-02449 MILL / 232-02450 CLEAR 232-02451 BLACK 17'',O /, /,17-,""' Signature with Seal .:- --...:••:4---'----'- '-'''':'7'- '-'' -''''---- '---N-fclb(3P DATE:06/05/2021 1.500 i PROJECT NAME&ADDRESS, _. " ' [. Ili j- .750 — 1 4 [ — w I >_ co cNi I— p in •832 N Z W LLI Q Pi_ N CY U 0 rn N QW Zp SECTION PROPERTIES -) a 1 p � 1.624 t U5 F- A 0.357 0 Ix in4 CENTROID 11 W cl x 0.125 m Q Ct cn i— 0 Iyy 0.132 in4 Y co _ Sx (TOP) 0.150 in3 792 0 EL Sx (BOT) 0.158 in3 Sy (LEFT) 0.175 in3 Sy (RIGHT) 0.175 in3 1 1 SHEET NAME ALL DIMENSIONS IN INCHES EQUIPMENT MATERIALS: 6000 SERIES ALUMINUM OPTIONS: SPECIFICATION DESIGN LOAD (LBS): N/A CLEAR/ BLACK ANODIZED SHEET SIZE ULTIMATE LOAD (LBS): N/A MILL FINISH ANSI B TORQUE SPECIFICATION: N/A LB-FT BUNDLES OF 144 11" X 17" CERTIFICATION: UL 2703, FILE E359313 BOXES OF 8 SHEET NUMBER WEIGHT (LBS): 5.85 PV-9