Permit CITY OF TIGARD MASTER PERMIT
' I . COMMUNITY DEVELOPMENT Permit#: MST2021-00262
Date Issued: 08/05/2021
T f G A tt O 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S107AA15800
Jurisdiction: Tigard
Site address: 16683 SW TOWNSVILLE ST
Subdivision: ROSHAK RIDGE Lot: 158
Project: Polygon at Roshak Ridge Lot 158
Project Description: New single detached house with deck
BUILDING
Floor Areas Required Setbacks Required
Stories: 3 Bedrooms: 5 First: 978 sf Basement:
841 sf Left: 3 Parking Spaces: 0
Height: 27 Bathrooms: 4 Second: 1331 sf Garage: 416 sf Front: 8 Smoke Yes
Dwelling Units: 1 Third: sf Right: 3 Detectors:
Total: 3150 sf Value: $409,391.85 Rear: 10
PLUMBING
Sinks: 1 Water Closets: 4 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0
Lavatories: 6 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100
Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0
Bckflw Prevntr: 0
Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1
Other Fixtures: 0
Drywell-Trench Drain: 0
Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1
Natural Gas Heat Pump: N Hoods: 1 Other Units: 0
Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 4
Furn>=100K: 0
ELECTRICAL
Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits
1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0
Ea add'l 500 sf: 6 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0
Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+amp/volt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All
Y
Other: N Other Description:
Ecompasing:
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
NEW SF VB R-3 3150
Owner: Contractor:
POLYGON WLH LLC WILLIAM LYON HOMES INC Required Items and Reports(Conditions)
703 BROADWAY ST STE 510 703 BROADWAY STREET,SUITE 510 1 Ersn Cntrl 503-639-4175
VANCOUVER,WA 98660 VANCOUVER,WA 98660 2 One Hour Fire Rated Eaves
3 Geo Tech Report Required
Prior To Pour
PHONE: PHONE: 360-695-7700
FAX:
Total Fees: $44,587.95
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work
will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more
the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
oc9-nnl-nnin rhrn,,nh nAR QS9-nnl_nnan vnii n, ,nhtoin a rnnu of fho ndoc nr riirort nnoefinne to ru INC hu, iiinn gm 919 10R7 nr 1 grin 2'29 94dd
Holly Vowt/De/Wege
Issued By: wy Permittee Signature: 0 Vli A ppliZarGOTI
Call 503.639.4175 by 7:00 a.m.for the next available inspection date.
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
Building Permit Application ._- , Z.7A/
Residential tiFIFIVFD FOR OFFICE USE ONLY
City g JUN I V 2 3 ?0 2 1 of Tigard ReceiveDate/By: 7 t d +I k
/ PertnitNo.:VII'q04ZoUZ 2
r 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review
= Phone: 503.718.2439 Fax: 503.598.196t'7 ^ , Date/By: a / , ♦ Other Permit: pa,i'-60 I go
• V�! Ut- !1�..7t"�1t`ItJ / Juris:
Inspection Line: 503.639.4175 'f )ied/Meth /
e ReeadyBy: 74 0 See Page 2 for
TIGARU Internet: www.tigard-or.gov BUILDING DIVISION /i r/4 Supplemental Information
TYPE OF WORK REQUIRED D'l ::1-AND 2-FAMILY DWELLING
®New construction ❑Demolition Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
❑Addition/alteration/replacement 0 Other: equipment,materials,labor,overhead,and the profit for the
CATEGORY OF CONSTRUCTION work indicated on this application. S�
® 1-and 2-family dwelling 0 Commercial/industrial Valuation: $ � ' �� I
0 Accessory building 0 Multi-family Number of bedrooms: 5
ElMaster builder ❑Other: Number of bathrooms.
JOB SITE INFORMATION AND LOCATION Total number of floors:3 `„
Job site address: 16683 SW TOWNSVILLE St New dwelling area: 3,150 square feet L J 1
City/State/ZIP:Sherwood, OR 97140 Garage/carport area: 416 square feet On
Suite/bldg./apt.no.: Project name:Polygon at Roshak Ridge Covered porch area: square feet r
Cross street/directions to job site: Deck area: t►1, square feet l
Other structure area: square feet
REQUIRED DATA:COMMERCIAL-USE CHECKLIST
Subdivision: Polygon at Roshak Ridge Lot no.: 158 Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the
DESCRIPTION OF WORK work indicated on this application.
New Construction/Type: SFU / Elevation plan: 222503BR Valuation: $
Projected start:November 2021 Existing building area: square feet
Deferrals: N/A New building area: square feet
® PROPERTY OWNER 0 TENANT Number of stories:
Name:Polygon Homes WLH LLC Type of construction:
Address:703 Broadway St., Ste 510 Occupancy groups:
City/State/ZIP:Vancouver, WA 98660 Existing:
Phone:(360) 946-8674 Fax:( ) New:
® APPLICANT 0 CONTACT PERSON U9 BUILDING PERMIT FEES*
(Please rejerto fee schedule)
Business name:Polygon Homes WLH LLC
Structural plan review fee(or deposit):
Contact name:Omar Alami Abouhafs
FLS plan review fee(if applicable):
Address:703 Broadway St., Ste 510
Total fees due upon application:
City/State/'ZIP:Vancouver, WA 98660
Amount received:
Phone:(360)946-8674 Fax::( )360 693-4442
E-mail: permitsubmittals@taylormorrison.com-OAIamiAbouhafs@taylormorrison.corn
PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES*
Commercial and residential prescriptive installation of
CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System.
Business name:Polygon Homes WLH LLC Submit two(2)sets of roof plan with connection details
and fire department access,along with the 2010 Oregon
Address:703 Broadway St., Ste 510 Solar Installation Specialty Code checklist.
City/State/ZIP:Vancouver, WA 98660 Permit Fee(includes plan review $180.00
and administrative fees):
Phone:( )360 695-7700 Fax:( )360 693-4442 State surcharge(12%of permit fee): $21.60
CCB lic.:207247 �/ �/` / _ Total fee due upon application: $201.60
Authorized signature: O/12. 4.. .rY .rY C 1,11. ad2 This permit application expires if a permit is not obtained
r/ within 180 days after it has been accepted as complete.
Print name:Omar Alami Abouhafs Date: 06/22/2021 *Fee methodology set by Tri-County Building Industry
Service Board.
I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(I 1/02/COM/WEB)
Mechanical Permit Applicatic FOR OFFICE USE ONLY
City of Tigard Received
t' Datefiiy: ?tip( Or Permit No. m f,12o? - Z Z
11 13125 SW Hall Blvd.,Tigard,OR 97223 3 2021Mau
rT
1 Phone: 503.718.2439 Fax: 503.598.1960 Date my, Other Permit: � `^0Z—
RU(,
tilt 11.1� Inspection Line: 503.639.4175 1GAR Date Ready/By: tarts @Sec Page 2 for
Internet: www.tigard-or.gov ;. Notificd/Method Su lementalInformation
BUILDINGIVISK;". pp
TYPE OF WORK COMMERCIAL FEE' SCh EDULE - USE CHECKLIST
Mechanical permit fees*are based on the value of the work
®New construction ❑Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all
❑Demolition 0 Other: mechanical materials,equipment,labor,overhead,and profit.
Value:S
CATEGORY OF CONSTRUCTION RESIDENTIAL EQUIPMENT/SYSTEMS FEES*
DR 1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building For special information use checklist
1 aMaid-family ❑ Master builder ❑Other: Description Qty. Ea. F Total
JOB SITE INFORMATION AND LOCATION Heating/cooling,:
Air conditioning I 46.75
Job site address: 16683 SW TOWNSVILLE ST Furnace 100,000 BTU(ducts/vents) 46.75
City/State/ZIP:Tigard,OR 97224 Furnace 100,0001 BTU(ducts/vents) 54.91
Suite/bldg./apt.no.: Project name: Polygon at Roshak Ridge
Heat pump 61.06 Duct work 23.32 I
Cross street/directions to job site: Hy(Ironic hot water_system 23.32
Residential boiler(radiator or
hydronic) _ 23.32
Unit heaters(fuel-type,not electric),
in-wall,in-duct,suspended,etc. 46.75
Flue/vent for any of above 23.32
Subdivision: Polygon at Roshak Ridge Lot no.: 158 other 23.32
Other fuel appliances:
Tax map/parcel no.: Water beater 23.3_2
DESCRIPTION OF WORK Gas fireplace/insert 33.39 _
New SFU construction Flue vent for water heater or gas
fireplace 23.32
Log lighter(gas) 23.32
- — —-- Wood/pellet stove 33.39
Wood fireplace/insert 23.32
Chimneyrliner/flue/vent 23.32
® PROPERTY OWNER 0 TENANT Other 23.32
Environmental exhaust and ventilation:
Name:Polygon WLII,LLC Range hood/other kitchen
_...__ equipment 33.39
Address:703 Broadway St.,Ste.510 - Clothes dryer exhaust 33.39
City/State/ZIP:Vancouver,WA 98660 Single-duct exhaust(bathrooms,
toilet compartments,utility rooms) 23.32
Phone:(360)695-7700 Fax:( ) Attic/crawlspace fans 23.32
® APPLICANT 0 CONTACT PERSON Other: _ 23.32
Fuel piping:
Business name:Polygon WLII,LLC
$14.15 for first four:$4.03 for each additional
Contact name:Tonja Morris Furnace,etc.
Address:703 Broadway St.,Ste 510 Gas heat pump
Wall/suspended/unit heater
City/State/ZIP:Vancouver,WA 98660 Water heater
Phone:(360)695-7700 I Fax::(360)693-4442 Fireplace
Ranee
E-mail:permitsuhmittalst taylofmofriSOD.COM Barbecue
CONTRACTOR Clothes dryer(gas)
Business name:Pro Heating&Cooling Other:
MECHANICAL PERMIT FEES'
Address: NW Alociek Dr,Ste.1104
Subtotal
City/State/ZIP:Hillsboro,OR Minimum permit fee($90.00)
Plan review(25%of permit fee)
Phone:(360)270-1590 Fax:( ) State surcharge(12%of permit fee)
CCB lie.:209001 TOTAL PERMIT FEE
This permit application expires if a permit is not obtained within 180
Q� days after it has been accepted as complete.
Authorized signature: "" �u Fee methodology se;by Tri-County Building Industry Service Board
Print name:Elia Duran Date 10/30/20
\anila+ne\Prrmirc\14rsr P.rmie Ann tm s,11 A..r ran.r.l rr. r mn vv.e.,neee o
Electrical Permit Application FNED
City of Tigard Received
'u 13125SW lailBlvd.,Tigard,OR 97223 �' 3 2U21 _ �Ptxmittt �so' '- Z4p2
* flan Review (epO
Phone. 503.718 2439 Fax. 503.59 ;960 Related permit t': G Oteia I-00 Q V
Inspection Line: 503 639 4175 Gi /r 1IGARD Dawns,
5uris_ f^c"
tor
."CARD Internet: www.0 and-or, ov Di !!lam' 1 fl1/1q!('M Y Y Bl pementlIn
$ $ ��.1j�� Notiticd''lytcdtad. supplemental Information
TYPE OF WORK _ PLAN REVIEW
®New construction ❑Addition/alteration/replacement Please check all that apply(submit a sets of plans whims checked)
El Demolition ❑Other: 0&iatce or feeder 400 amps a more ❑Budding over three stones
where the available fault current 0 Marinas and boatyard,
CATEGORY OF CONSTRUCTION cowed.'10,000 amps at 150 volts or ❑F1oatmg buildings
® 1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building less tou =or exceed 14.000 ❑Commercial-use agricultural
amps for all other installations buildin
0 Multi-family ❑Master builder ❑Other; ❑Fire pump R 0 Installation of 150 KVA or
JOB SITE INFORMATION AND LOCATION 0 1:mergeney system larger separately derived
Job#: Job site address:16683 SW TOWNSVILLE ST ❑ 001IPurmorion of ssmoeorload rf s''`t`�-
1001TP o>r more. ❑"A`,"k.°","1-2"•"I-3",
City/State/ZIP: Tigard,OR 97140 ❑six or more reside-owl units occupatv-y
_.. ❑Health-care facilities. 0 Recreational vehicle parks.
SuitclbldgJapL#: Project name: Polygon at Roshak Ridge ❑Hazardous locations ❑Supply voltage for more than
❑Service or Icedct 600 amps or more 600 volts nominal.
Cross street/directions to job site: FEE SCHEDULE
-..... Description I Qty. I Each I 'fatal 1
New residential single-or multi-family dwelling unit,
Subdivision:Polygon at Roshak Ridge Lot#: 158 Includes attached garage.
fax map/parcel#:
1,000 sq 11.or less 168 54 4
F,a.add'!500 sq.it.or portion 33 92 1
DESCRIPTION OF WORK Limited tangy,rrsidtutial
Nett'construction.Type SFU N (with above sq.ft.) 75.00 2.
I ..... [muted ctaagy,multi-family 75.00
residential(with above sq.ft.)
Renewable Energy 0 See Page 2
El PROPERTY OWNER ❑ TENANT Services or feeders installation,alteration,and/or relocation
Name: Polygon Homes WLH LLC 200 amps or less 100.70 2
Address: 703 Broadway St.,Ste 710 201 amps to 400 amps 133--- 2
_ 401 amps to 600 amps 200 34 2
City/State/ZIP: Vancouver,WA 98660 601 amps to 1,000 amps 301 04 _ 2
Phone:( 360 )946 8674 Fax:( ) Over 1,000 amps or volts 552.26 2
Temporary services or feeders installation,alteration,and/or
Email: OAiamiAbouhafs@taylormorrison.com-PermitSubmittals(a taylormorrison-coat relocation
Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 I
intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125 08 2
Owner signature: _ Date: 401 amps to 599 amiss 168 54 2
❑ APPLICANT __ ❑ CONTACT PERSON Branch circuits--new,alteration,or extension,per panel
A Fee for branch circuits with
Business name: Polygon Homes WI.H LLC above service or featix fee,
each branch circuit 7 42 -
Contact name: Omar Alami Abouhafs El Fee for branch circuits without
service or feeder fed,first Address: 703 Broadway St.,Ste 710 branch 56.18 2
circuit
City/State/ZIP: Vancouver,WA 98660 Each add'!branch circuit 7.42 2
Miscellaneous(service or feeder not included)
Phone:(360 )946 8674 Ems,:
( ) Each manufactured or modular 67 84
dwelling,service and/or feeder
Email:OAlarniAbouhafs@taylormorri son.com-PennitSubmittals@taylormorrison.com Reconnect only 67 8.4 2
CONTRA(11011 Pump or tm fation circle 67 84 2
Business name: Wallace Electric Sign or outline lighting 67 84 2
Signal eircuit(s)or hmited-energy
Address: 105 Dresden St ❑ See Page 2 2
panel,alteration,or extension.
City/State/ZIP: Astoria OR 97103 Each additional inspection over allowable in any of the above
Additional inspection(l fu min) 66 25/1u i
Phone:(501 308 0563 Fax:( ) Investigation(1 hr min) 9O.0Xlt hr
Email: David@wallacewires.com
ires.com Industrial plant(1 hr min) 78 Bair br
Inspections for which no lee is
CCII lie.;224868 Electrical Li-, CI 441 Su v. 1, .: 6363S specifically listed(Is hr min) 40 00/hr
ELECTRICAI, PERMIT FEES
Suprv.Electrician signature,required: il.. �^�" Subtotal
Print name;D. tp �•1;_ Date: q / (/l��t"_"' ❑Plan Review Required(25%ofpermit fcc):
t { State surcharge(12%of permit fee)
Authorized signature �� TOTAL PERMIT EGG:
This permit application expires if a permit is not obtained within ISO
Print natnC: _ l)atc. days after it has been accepted as complete.
-- eLJ1f4 _ t + Number of inspectruus allowed per permit.
I:iusldtng'd'cralil5'd:T.c_PerteitApp_EIR ORE.dcc Rev 06,17/2015 d,v-l6151.(1 l/45rCOA/WF9
Plumbing Permit Application Building Fixtures RECEIVED FOR OFFICE USE ONLY
City of Tigard Received
t Permit No.:MsC Z
+� Date/Bv: n
's 13125 SW Hall Blvd-,Tigard,OR 97223J U N 2 3 L 0 21 Plan Review ���t�2� N� ��
31- Phone: 503.71$.2439 Fax: 503.598.1960 Other Permit No: 5'(pQ. 1-0
Date.E3v:
TIGARD Inspection Line: 503.639.4175 CITY OF TIGARD pate Ready/By: to a 11 See Page 2 for
Internet: www.tigard-or.gov 3U?LDING DIVISION _Notified/Method: Supplemental Information
TYPE OF WORK FEE* SCHEDULE
®New construction 0 Demolition For special information use checklist.
- __ Description I Qty. j Ea. I Total
0 Addition/alteration/replacement 0 Other: New 1-2-family dwellings(includes I00 ft.for each utility connection)
CATEGORY OF CONSTRUCTION SFR(1)bath 312.70
I-and 2-family dwelling ❑Commercial/industrial SFR(2)bath 437.78
SFR(3)bath 500.32
0 Accessory building 42-Multi-family - -
Each additional bath/kitchen 25.02
❑Master builder 0 Other: Fire sprinkler( sq.ft.) Page 2
JOB SITE INFORMATION AND LOCATION Site utilities:
Job site address: 16683 SW TOWNSVILLE ST Catch basin or area drain 18.76
City/State/ZIP:Tigard,OR 97224 Drytvell,leach line,or trench drain 18.76
Footing drain(no.linear ft.: ) Page 2
Suite/bldg./apt.no-: Project name:44riskorkpfkizeg.Polygon at Roshak Ridge Manufactured home utilities 50.03
Cross street/directions to job site: Manholes 18.76
Rain drain connector 18.76
Sanitary sewer(no.linear ft.:_) Page 2
Storm sewer(no.linear ft.:_) Page 2
Water service(no.linear ft.: ) Page 2
Subdivision: Polygon at Roshak Ridge Lot no.: 158 Fixture or item:
Tax map/parcel no.: Backflow preventer 31.27
DESCRIPTION OF WORK Backwater valve 12.51
New SFU construction Clothes washer 25.02
Dishwasher 25.02
- _
Drinking fountain 25.02
Ejectors/sump 25.02
0 PROPERTY OWNER 0 TENANT Expansion tank 12.51
Name:Polygon WLH,LLC Fixture'sewercap 25.02
Floor drain/floor sink/hub 25.02
Address:703 Broadway St,Ste 510
Garbage disposal 25.02
City/State/ZIP:Vancouver,WA 98660 Hose bib 25.02
Phone:(360)695-7700 Fax:( ) Ice maker 12.51
0 APPLICANT L ❑ CONTACT PERSON Interceptor/grease trap 25.02
Business name:Polygon WLH,LLC Medical gas(value:S ) Page 2
Primer 12.51
Contact name:Tonja Morris
Roof drain(commercial) 12.51
Address:703 Broadway St.,Ste 510 Sink'basin lavatory 25.02
City/State/ZIP:Vancouver,WA 98660 Solar units(potable water) 62.54
Phone:(360)695-7700 Fax::(360)693-4442 Tub./shower/shower pan 12.51
E-mail:permitsubmittalstlipolygonhomes.corn Urinal 25.02
Water closet 25.02
CONTRACTOR
Water heater 37.52
Business name:G&B Plumbing&Sons Inc
Water I m iDVV 56.29
Address:P.O.Box 92 Other: 25.02
City/State/ZIP:St.Paul,OR 97137 Subtotal
Phone:(503)868-1417 Fax:(971)727-8170 Minimum permit fce: S72.50
Plan review (25%of permit fee) 1
CCB Lic.: 184372 �� Plumbing Lic.no.:pb634 State surcharge(12°l0 of perm
b TOTAL PERMIT
feel
Authorized signature: �j=� V e� -� FEE
Print name:Steve Fowler I Date: 1 0/30/20 This permit application expires if a permit is not obtained within 180 days
after it has been accepted as complete.
*Fee methodology set by Tri-County Building Industry Service Board.
Il Building\Pcrnits5LMU-PermiiApp-doc I0/0U05 440-4616r(10w02.COM,WEB)
f
City of Tigard
III COMMUNITY DEVELOPMENT DEPARTMENT
■
T 1 cA R n Building Permit Review — Residential
Building Permit #: f WIDI\'(Vial
Site Address: 16683 SW Townsville St
Project Name: Polygon at Roshak Ridge Lot #: 158
Planning Review
Proposal: New house
SIC Verify address/suite# active in Accela. K] In River Terrace: ❑ No lk Yes, River Terrace Review Addendum
Site Plan Elements: WErosion Control
®3 copies of site plan on 8-1/2"x 11"or 11 x 17"paper flRetained trees with drip line and tree protection measures
flDrawn to scale(standard architect or engineer scale) k Footprint of new structure(including decks)and FFE
Xi North arrow kUtility locations&easements(required for new and additions)
Site address,project or subdivision name and lot number $]Sidewalk/driveway approach
[ Applicant information(name and phone number) Ia,ocation of wells/septic systems
ZILot dimensions and building setback dimensions ®Street tree size,type and location
square footage of buildings to be demolished a Street names
existing structures on site ®Corner elevations(2'contours if more than 4'differential)
1Lot area,building coverage area,percentage of coverage and >1,000 sf of impervious area created or replaced? ❑ h0No
impervious area (applicable if R-7,R-12,R-25&R-40) If yes,is a storm water quality facility shown? es No
® Clean Water Services—Service Provider Letter(lot platted prior to 9/10/1995):
Required: ❑ Yes,applicant was notified ® No Received: ❑ Yes ❑ No
X Water Meter Fixture Unit Worksheet—Additions,Remodels and ADUs
Required: ❑ Yes,applicant was notified ® No Received: ❑ Yes ❑ No
q SDC exemption for ADU applied for: ❑ Yes jil No Received: ❑ Yes ❑ No
] Public Facilities Improvement (PFI) Permit
Required: ❑ Yes,applicant was notified ® No Applied For: ❑ Yes ❑ No,stop intake
IN Land Use Case#: SUB2015-00004 E Zoning: R-7 / R-12
® Required Setbacks: Front: 8 Rear: 10 Side: 3 Street Side: na Garage: 20
$I Building Height: Max.Height: na Actual Height: ±2-1
! Landscape Area: 20 % ® Lot Coverage Max: 80
❑ Set back no more than 8'from street-facing wall ❑ Parallel to street or offset 45 de re
Windows • 12%of area of all street-facing facades
Garage ❑ Garage door i ' est street-facing wall ❑ Ye ,one of the following is met:
❑ Door extends no --r.--,11 --11-1,,- - ,I ,,,A, -+ending beyond garage.
CI Door extends no SEE RIVER TERRACE ADDENDUM bove garage on 2nd floor.
❑ Garage door width is r ess Li 50%or less o GO%or less and includes 7 of following:
❑ rc ❑ Recessed entrance ❑ Wall offset ❑ 1 ❑ Roof offset
Fire shingles ❑ Lap Siding ❑ Roof pitch ❑ Gable,hip,or gambrel roo mer
❑ Accent siding ❑ Window trim ❑ Window recess ❑ Window projection ❑ B c
IE Visual Clearance ':1 Urban Forestry Plan
f7 Sensitive Lands: ❑ Yes X No Type:
] Conditions met prior to issuance of building permit
Notes:
® Approved By Planning: Arerole---.— Date: (Q 12- 4 2.0Z 1
Revisions (after Building Submittal only) Reviewer Date
Revision 1: ❑ Approved ❑ Not Approved
Revision 2: 0 Approved 0 Not Approved
I:\Building\Forms\Bl dgPermitRvw_RES_122419.docx
,
Building Permit Submittal
Original Submittal Date: 6.414i
Site Plans: # '7
Building Plans:
Building Permit#: Enter building pe . above.
Workflow Routing: %Planning ngineering t Coordinator ding
Workflow Sign-off: ign-off for Planning(include notes from planning review)
Route Application Documents: Pg. En •' eering: (1) copy of permit application, (1) site plan, (1)building plan and
riginal plan review routing form.
Building: original permit application,site plans,building plans,engineer and
beam calculate, s and trust details,if applicable,etc.
Notes:
/
By Permit Technician: jar am-- Date: _7/ /0(
Engineering Review
Slope at building pad: 2-444
CQi Conditions "Met"prior to issuance of building permit de//051--
Easements (encroachments)per engineering conditions of approval and plat
Water Quality/Quantity Facility
Assess Water Quality Fee in-lieu: ❑ Yes 'No
Assess Water Quantity Fee in-lieu: ❑ Yes No
LIDA Facility on lot ❑ Yes L4'' Io
[ hinal Plat Recorded:
❑ NOT Approved by Engineering: Date:
Notes:
Approved by Engineering: Date: 7 1 Z
Revisions (after Building Submittal only) Reviewer Date
Revision 1: ❑ Approved ❑ Not Approved
Revision 2: ❑ Approved ❑ Not Approved
Permit Coordinator Review
7(Conditions "Met"prior to issuance of building permit
❑ Approved,NOT Released: Date:
Notes:
Revisions (after Building Submittal only)
Revision Notice 1: Date Sent to Applicant:
Revision Notice 2: Date Sent to Applicant:
0 ❑ RecSDC Exemption:
eived Does not apply
SDC Fees Entered: Wash Co Trans Dev Tax: Yes ❑ N/A
Tigard Trans SDC: /Yes ❑ N/A
Parks SDC: /Yes ❑ N/A
LIDA ❑ Yes if N/A
pi OK to Issue Permit
Approved by Permit Coordinator: lbill & Date: 1116(2011
I:\Building\Forms\BldgPermitRvw_RES_122419.docx
City of Tigard
114 COMMUNITY DEVELOPMENT DEPARTMENT
T 1 c A R D River Terrace Building Permit Review Addendum
Building Permit #:
Site Address: 16683 SW Townsville St
Project Name: Polygon at Roshak Ridge Lot #: 158
(New dwelling=subdivision name;Addition or Alteration=last name of owner)
Pla1211-11V.Review ofJ iver ?'errace Plan District besiin Standards (18.640.070.)):
Is the project subject to the plan district design standards? ® Yes ❑ No
1.Articulation: a minimum of 1 element per each street-facing façade that has 30-60 ft. of frontage. An additional
element required for lots with over 60 ft. of street frontage shall be provided every 30 ft.
Balcony w/ access 2 Window Projection Vertical Wall Offset a
Porch min. 5 ft. deep ft. deep min. 2ft., 5 ft.wide min. 2 ft., 6ft.wide Gabled dormer
2. Eyes on the street: a minimum of 12%of each street facing facade must include windows or entrance doors.
Percentage Shown: 14%
3. Entrances:At least one entrance must meet both of the following standards:
Max. 8 ft. setback from longest street facing wall g Parallel to street, angle no more than 45° from street,
or open onto porch
Entrance opens to a porch: ® Yes ❑ No
If yes,all the following apply: ® 25 sq.ft. min.
$] One street facing entry 1) 12 ft. max.roof above floor of porch
CA 5 ft.depth min. ® 30%min.porch roof coverage
4. Detailed Design:All buildings shall include a min. of five of the following elements on all street-facing facades:
Kl Covered porch min. 5 ft.wide x 5 ft. deep Recessed entry area min. 5 ft.wide x 2 ft. deep
ki Wall offset min. 16 inches ❑ Dormer min. 4 ft.wide
Roof eave min. 12 inch projection ® Roof offset min. of 2 ft.
❑ Roof shingles either tile or wood ® Gable,hip or gambrel roof design
❑ Roof pitch oriented south min. 500 sq. ft. ❑ Horizontal lap siding min. 3-7 inches wide
❑ Accent siding min. 40%of street facade ® Window trim min. 2 1/2"wide by 5/8" deep
❑ Window recess min. 3 inches for all street facing ❑ Bay window min. 5 ft.wide by 2 ft. deep
❑ Balcony min. 5 ft.wide x 3 ft. deep with inside access ❑ Attached garage is 35% or less of street facade
5. Garages and Carports:May face the front or side lot line on a corner lot.
Setbacks:
No closer to front or side lot line,than longest street-facing wall. ® Yes ❑ No. If No (Check one):
❑ May extend up to 5 ft.if there is a covered front porch and garage does not extend beyond the front porch.
❑ May extend up to 5 ft.where the garage is part of a two-story building and there is a window at the second story
above the garage that faces the street with a min. area of 12 sq.ft.
Width: (Check one)
❑ 12-foot-wide garage door ❑ 40%max. of street façade
• 50%max. of street facade with 7 detailed design elements
Notes:
Approved By Planning: Date: (. ((21 1Z41. 1
I:\Building\Forms\BldgPermitRvw_RES_RT_121417.docx V T
laylorMorri son.
Polygon at Roshak Ridge, Lot 158 RECEIVED
New submittal JUN 2 3 2021
CITY Of -I'IGARD
BUILDING DIVISION
Subject: New residential construction — SFU.
Address: 16683 SW TOWNSVILLE ST.
Elevation: 222503BR.
Total R3 occupancy: 3,150 SF.
Projected start: December 2021.
This packet contains the following documents:
• 1x Building application.
• 1x Mechanical, Electrical and Plumbing applications.
• 3x Site plan (size: 11"x 17").
• 2x Structural calculations.
• 2 x Basement floor layout (size: 11"x 17").
• 2 x Basement floor Calculations.
• 2 x Main floor layout (size: 11"x 17").
• 2 x Main floor Calculations.
• 2 x Upper floor layout (size: 11"x 17").
• 2 x Upper floor Calculations.
• 2x Roof truss Layout (size: 11"x 17").
• 2x Roof truss Calculations.
• 3x Architectural plans (full size).
Thank you
taylor TaylorMorrison.
morrison.
Hoxar svreabyYoi, COMMUNITIES