Report Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
I,
, am the general contractor or the owner-builder
at the following address:
Site Address:
1(-A 7_0 5 Cs-v-AA C
City:
t
Permit#:
Subdivision/Lot#:
2.)
and/or
Map and Tax Lot#:
To conform with the 2014 Oregon Residential Specialty Code(ORSC), Section R408,1
Ventilation. I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
1.-Rlhe ground surface of the under-floor space is covered with 6-mil black polyethylene
sheeting with
[ }fiats lapped 12"at seams and
{ ending up the foundation walls 12".
Signature: Date:
or Owner-Builder
IABui1dingTonn1RES-Moistureaarriendoc 09/13/2016
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
, am the general contractor or the owner-builder
at the following address:
Site Address:
(:-.)
City:
Permit#:
Subdivision/Lot#:
and/or
Map and Tax Lot#:
To conform with the 2008 Oregon Residential Specialty Code(ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes,the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
r-'s\
Signature:
Date: LI/I Li/t
cto or Owner-Builder
1:\Buildnieform\RES-MoistureSensitiveWood.doc 09/25/08
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: As-c- 4.0 et coos..1 Jurisdiction:
Site Address:
luk b 6,6A Cac,-,
Subdivision/Lot#:
and/or
Map and Tax Lot#:
By my signature below, I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code N1107.2)1
Si •
Date:
tractor/Authorized Agent
Print Name: n,,A.Az-L
1 ORSC Section N1107.2.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that
has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this
requirement
The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per
input watt.
1:\BuildineForms\RES-IlighEfficieneyLighting,doc 07/01/08
Moffet Energy Modeling
CCB#223372
Phone:916-342-0742
tvlermoffet@moffetenergvmodeling.com
Blower Door Test Affidavit
Permit#: Builder: Polygon
Site Address: Eastridge Lot 118:14208 SW Gold Coast Terrace,Tigard,OR 97224
Conditioned Floor Area (sq.ft.): 1554
Source:Calculated from plans Calculated Building Volume (cubic feet): 14970
TEST RESULTS: 876 CFM @ 50 Pa
ACH @ 50 Pa={(CFM x 60)_Volume}: 3.51
Ring: Open oA B
Minneapolis Blower Door and DG 700 Manometer
I certify that these building leakage rates are accurate and determined using standard BPI testing
protocol.
Company Name: Moffet Energy Modeling Technician:Tyler Moffet
Technician Signature: -7 4/40
Date: 4/10/2020