Plans HOOD INFORMATION �J r� ��5 / is HOOD DIMENSIONS(IN.) COOKING EXHAUST SUPPLY TOTAL i(// /�_�/�-�/ / /z�� EXHAUST ONLY DOUBLE SHELL FRONT DETAIL HOOD MARK MODEL HOOD LOAD/ TOTAL COLLAR(S) MUA AC WEIGHT SECTION v !�� vvAl NO. LENGTH WIDTH HEIGHT CONSTR. DUTY LOCATION RATING CFM WIDTH LENGTH DIA. CFM S.P. CFM CFM LBS. /' /� RECEIVED INSULATION0R 430 SS 14 1800 0.809 `�3 �[ ���% �rooD Fao"r RANEL `;000 1 H-1 XXDW-72-S 72 66 24 WHERE HEAVY 1800 288 SINGLE T , / EXPOSED _ INTERIOR SHELL HOOD INFORMATION HOOD ,'"TER LIGHTING DETAILS GREASE FILTRATION DETAILS UTILITY CABINET(S) HEIGHT PERFORMANCE ELI Q > R 2 0 .a 0.750 f HEM D HOOD MARK FIXTURE TYPE FOOT TYPE/MODEL SIZE(IN.) FIRE SYSTEM CONTROLS CONSTRUCTION W/U FREE CLOSED J NO. BULB/LAMP INFO OTY CANDLES MATERIAL OTY L H LOCATION TYPE SIZE MODEL INTERFACE ui rt OF TIGARD °- LEFT ANSUL R102 OVERLAP 6 2.125 �.-- (n INCANDESCENT(GLOBE) X-TRACTOR 2 16 ' 1 H-1 100W A19(BULBS NOT INCL.), 2 39.21 STAINLESS STEEL 2 20 20 3UILDING DIVISION HOOD FRONT SECTION VIEW o HOOD OPTIONS AVAILABLE ON EXHAUST ONLY RECTANGULAR HOOD MODELS ONLY Q UL 710 LISTED W/OUT EXHAUST FIRE DAMPER-UL#R25625 z 2 BACK INTEGRAL AIR SPACE-3 IN WIDE HOOD HANGING HEIGHT FOR FIRE SYSTEMS J FINISHED BACK-FULL LENGTH VERIFICATION OF HOOD HANGING HEIGHT ABOVE FINISHED FLOOR(A.F.F.) ' SHIPPED LOOSE EXHAUST COLLAR(S) IS REQUIRED FOR CORRECT PLACEMENT OF FIRE SYSTEM NOZZLES, H PERFORMANCE ENHANCING LIP(PEL)TECHNOLOGY RECOMMENDED HANGING HEIGHT=BU FROM Q STANDING SEAM CONSTRUCTION FOR SUPERIOR STRENGTH 0 FINISHED FLOOR TO LOWER FRONT EDGE OF HOOD. C OTHER HANGING HEIGHT= "FROM r0 CL FINISHED FLOOR TO LOWER EDGE OF HOOD, V HOOD HANGER BRACKET DETAIL pFFICE COPY NOT TO SCALE 1 R ~c aEAOEo U N 1' BRACKET �O ci'4.0 WrvcEa rs 'N O 2 sNER e a° REFERENCE SCALED DRAWING FOR ncnAL LOCATIONSII CP' eancKEr o�o • WTTYPIAL HOOD NGI° 0 -1 3.6 3.6 36 0 HOOD LENGTH x W Y DC SHIPPED LOOSE DUCT COLLAR INST.DETAIL ,0 o r 30 ❑Y<cp, l. i7 AIRSPACE roc n F crc smiory GTM 4 Z V 3.0 T j���sT/1 f a 1.oa vz¢o REAR INTEGRAL)R SPACE Q V ; 9d 9.0 > —1- ma 's � � � T+, )14 jjDIA O T `1 %_L 2 cn 0 36 IN.00 0 66.0 8.0 8.0 HOOD LENGTH :1 I,- X 72.0 L -+ 12.0 84.0 MARK:H-1-SECTION 1 PLAN VIEW 0 4.0 D i !, �� WI I 24.0 CONTROL PANEL J i ,,%! 0 USER INSULATED DOUBLE INTERFACE ® ® SHELL FRONT PANEL 0UL LISTED LIGHT FIXTURE 104.0 i . 80.0 % UL LISTED HIGH EFFICIENCY 6.0 �30.O—i ABOVE • FINISHED GREASE-X-TRACTOR.FILTERS � /� FLOOR REMOVABLE GREASE CUP Wl ,� IX CONCEALED GREASE TROUGH 0/ INTEGRAL AIRSPACE �� o u j� oyi agx 3 G m FULL LENGTH FINISHED BACK MARK:H-1-SECTION 1 MARK:H-1 ELEVATION VIEW SECTION VIEW r g Direct Drive Upblast Centrifugal Roof Exhaust Fan �'��9 MARK INFORMATION FAN INFORMATION _ MOTOR INFORMATION • OTY MARK MODEL VOLUME TOTAL EXTERNAL SP FAN OPERATING WEIGHT SIZE(HP) V/C/P ENCLOSURE M OTOR WINDINGS NEC FLA* (CFM) (IN WG) RPM POWER(HP) (LB.) RPM 1 EF XRUD-130-VG 1,800 0.998 1,721 0.57 76 0.75 115/60/1 OP 1725 1 13.8 *NEC FLA-Based on table 430.250 or 430.248 of National Electrical Code 2017.Actual motor FLA may vary for sizing thermal overload,consult factory" Q J EF:SELECTED OPTIONS AND ACCESSORIES d One piece fully welded windband Tapered bushing wheel hub a -- Breather tube outlet area min.4.4 sq.in.(sizes 99-480),2.0 sq.in.(sizes 60-95) Q Min.windband material thickness:0.051"aluminum(060-240),0.064"aluminum(240HP,240XP), Z W 0.080"aluminum(sizes 300-480) Q Standard Curb Cap Size-19 in.Square J UUcUL 762 Listed-"Power Ventilators for Rest.Exh.Appliances" I— I Switch,NEMA-1,Toggle,Shipped with Unit a Hinged Base(Attached) a, High Temp Curb Seal Rated for Continuous Duty at 1500 F(Attached) d Grease Trap(PN 475538) p -Th wo ct N a O_M 2 0 U X w wQDD UO O Q v U Q o a pccQco a2v a U Z 0 co a SUGGESTED ROOF OPENING II TSab ele 14S.Q50 RECOMMENDED EXHAUST DUCT SIZE 'ft _ W DUCT TYPE SIZE STANDARD 14 SQ f IRE-WRAPPED 4 SQcr 24.88r-0 24.88 ::: 1...--0 1 28.25 16.50 • i • I +I 3.44 I LI 'yrI I I 52.25 I 52.25 7.75 17.75 (24I.00) (24.00) 40'711 o 24.00 Cilli) -J 19.00 SQ L i 19.00 SQ L 2 21.75 DUCT DIMENSIONS ARE LARGEST POSSIBLE DUCT TO FIT THROUGH CURB. CONSULT SYSTEM DESIGN ENGINEER FOR RECOMMENDED DUCT SIZE. OVERALL HEIGHT MAY BE GREATER DEPENDING ON MOTOR,ADAPTER,AND/OR HINGE BASE. • CONTROL INFORMATION CONTROL FEATURES ®$ ELECTRICAL CONTROL PACKAGE USER INTERFACE 2 POSITION LIGHT SWITCH-QTY 1 CONTROL PANEL'LF'INSTALLATION DETAIL MARK MODEL LOCATION TYPE LOCATION 2 POSITION FAN SWITCH-QTY 1 CONTROLS SWITCHES SWITCHES HOOD-FACE MOUNT LEFT END OF H-1 CC„nnVO�T wEi cE` �` NE I,,,' FAN STARTERS ■- LEA' BY OTHER Q a_ S,ITCHES HOOD MOUNTED C OF REMOTE Q z J p U 0 CL a_ Wo cc O N Q 0_ O U } �U o 0 Y UQ r2CQ LI X Q G co Qa U Z O w D 0 0 i FIRE SYSTEM INFORMATION 412 MARK MODEL LOCATION FLOW POINTS SUPPLY DETECTION MARK(S)PROTECTED BY FIRE SYSTEM ANSUL R102 (WET CHEMICAL)OVERLAPPING FIRE PROTECTION SYSTEM HOODS PCU LINE CONTROL PANEL ANSUL R-102 8 UTILIZED H-1 SECTION 1 FIRE SYSTEM OVERLAPPING CABINET-LEFT END OF H-1 CONTINUOUS FUSIBLE LINK STAINLESS TANKLOS WRING DIAGRAMS WET CHEMICAL 12 AVAILABLE As CARTRIDGEW/DPOT MICRO SWITCH EXPELLENT LEASE5 REGULATOR 6.KNOCKOUT FOR WIRING MICROSNATCH WIRED EO PER TYPICAL EXAMP ES SHOWN T SWITCHES PROVIDED BY TVERIFY URER MAY CONNECTION FIRE SYSTEM OPTIONS AND ACCESSORIES 1LOCAL CODES He°Eo`�oRv"oualHPs:Inoo AS rw"E FULL INSTALLATION(INCLUDES PRE-PIPED HOOD(S)WITH DETECTION AND FACTORY COORDINATED INSTALL) O I CONNECTION TO BUILDINGS ALARM Q CHROME SLEEVES FOR FACTORY PROVIDED APPLIANCES DROPS-INCLUDED ��� 0 235 d OVERLAPPING PROTECTION TYPE-FULL HOOD 2I FLZ- 6 """} :�' .I CO METAL BLOW-OFF CAPS-INCLUDED B ` ' ° ` Q/ [IS ne 0 W GAS VALVE-INCLUDED-MECHANICAL SHUTOFF VALVE,2",(ANSUL)-PART#ANSULMECHSHUTOFFVALVE200 , 5 yB Y CONNECTION To COOKING 0 H 1e5 EQUIPMENT SHUT DOWN >- HOOD SUPPRESSION AGENT-INCLUDED-6 GAL.-((2)3.0 TANK(S)J I►' Z CO REMOTE PULL STATION-STANDARD-INSTALLATION AT SINGLE POINT OF EGRESS NOT TO SCALE �_� `°°ar", ,�„�, lU • NOTES: E. :",} ..�.a.m® ,_ ,_ ,,, WET CHEMICAL FIRE PROTECTION SYSTEM TO BE ANSUL R-102.DESIGNED IN �,yam rfw' aA c.a.z O I COMPLIANCE WITH UL 300 REQUIREMENTS. ¢,vmul -VERIFICATION OF ALL COOKING EQUIPMENT MAKE,MODEL AND LOCATION ^ REQUIRED FOR ALL FIRE PROTECTION SYSTEMS. EL -ALL FIRE SYSTEM PIPING IS STANOAROLY TO THE RIGHT END OF THE HOOD CONNECTION TO FAN SHUT DOWN 0_UNLESS A WALL IS LOCATED ON THE RIGHT END. -ANSUL AUTOMAN RELEASE TO BE LOCATED WITHIN 60"OF HOOD. rn THE BASIC FIRE SYSTEM SKILL INCLUDE THE FOLLOWING' lop. V III♦ -GAS SHUT-OFF VALVE,IF REQUIRED,TO BE SUPPLIED BY MANUFACTURER(UP "M)"^^ TO 2.DIAMETER AS STANDARD),AND INSTALLED BYA LICENSED PLUMBER. -MICRO SWITCH TO BE SUPPLIED BY MANUFACTURER FOR CONNECTION TO. •N- `IKKI z >a BUT NOT LIMITED TO,BUILDING ALARM SYSTEM(S),EXHAUST AND SUPPLY FANS • AND ELECTRICAL POWER SHUT DOWN.FIELD WRING AND CONNECTIONS TO BE YAWN 6"""" ( `1 PERFORMED BY LICENSED ELECTRICIAN. ,en,mxwvc r ww®frnn, za.z WED Et THE BASIC FIRE SYSTEM DOES NOT INCLUDE THE FOLLOWING: -FULL DUMP TEST OTHER THAN N/HT IS SPECIFIED PER THE INSTALLATION 0-,- MANUAL,OR TO SATISFY A STATE OR LOCAL CODE.PERMIT AND TESTING FEES Et 2 ARE NOT INCLUDED UNLESS NOTED UNDER THE EQUIPMENT SCHEDULE FOR CL CO THE FIRE SYSTEM. -MORE THEN TON TRIPS TO THE JOBSITE OR SPECIAL TRANSPORTATION,OR OVERNIGHT LODGING REQUIREMENTS IN REMOTE AREAS.NORMAL TRAVEL DISTANCE IS FIRST 5O MI.(80.5 KM)FROM OFFICE. -SPECIAL CLASSES OR ADDITIONAL LABOR FOR ACCESS TO SECURITY SENSITIVE AREAS. -INSTALLATION OF GAS SHUT-OFF VALVE. 0 -SPECIAL DRAWINGS REQUIRED TO SATISFY STATE OR LOCAL CODE.PLAN 0 EXAMINATION FEES,PE OR FS APPROVAL STAMP, -UNION LABOR.GOVERNMENT LABOR.OR PREVAILING WAGES REQUIRED FOR X FINAL FIELD HOOD-UP. W -ANY AND ALL ELECTRICAL COMPONENTS/CONNECTIONS REQUIRED TO SHUT IX DOWN FANS,SHUTOFF DEVICE FOR ELECTRIC COOKING EQUIPMENT(SHUNT >-. =TRIP BREAKER),OR ACTIVATE AN ALARM SYSTEM,ETC. CQ 0 0 -ANY DISMANTLING OR REASSEMBLY REQUIRED TO GAIN ACCESS TO THE FIRE y'C 0 SUPPRESSION PIPING LOCATED ON THE TOP OF THE HOOD. AlEI oo -ROUGH-IN HIDDEN CONDUIT FOR REMOTE PULL STATION OR GAS VALVE Z Al CI -INSTALLATION OF ORE THAN(1(FLUSH MOUNTED PULL ))REMOTE PULL STATIONS OR DISTANCES NOTES. X>2 M FT S FIELD FACTORY INSTALLION ATION ~ -PARTSGREATER LABOR IMJDENOTES ON 0 Z Q O -PARTS OR LABOR REQUIRED TO CORRECT PIPING DUE TO COOKING WIRE ON SNAP-ACTION SWATCH IN Q C CC O EQUIPMENT CHANGES OR DEVIATION FROM PLANS.OR ANY CHARGES FOR NORMAL INSTALLATION.BLACK WIRE TO BE USED ONLY IBC Q OD MISSING OR ADDITIONAL PARTS OTHER THEN THOSE INDICATED ON THE FIRE FOR EXTRANEOUS ALARM,LIGHT CIRCUITS.ETC. Q 2 SUPPRESSION DETAIL. Q Q U Z 0 m Q w ce .. U 0