Report (5) Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
am the general contractor or the owner-builder
at the following address:
Site Address: t-i3.01-C( SL-) k
City:
Permit#:
Subdivision/Lot#: (44,
and/or
Map and Tax Lot#:
To confordrwith the 2014 Oregon Residential Specialty Code(ORSC),Section R408.1
Ventilation.lam notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
[ The ground surface of the under-floor space is covered with 6-mil black polyethylene
sheeting with
DiCints lapped 12"at seams and
[Ig•-xtending up the foundation walls 12".
'
fp .7 7,0
Signature: ' Date:
or Owner-Builder
I 4iutldiostFone RES-Mouturil ariff doc !mole
Oregon Residential Specialty Code R318.2
------------
MOISTURE CONTENT ACICNOWLEDGEMENT FORM
't CA,\---• am the general contractor or the owner-builder
at the follovving address:
Site Address.
t(47,1A Lts2C(b" A .
City:
.‘
Permit#:
Subdivision/Lot#:
and/or
Map and"Tvx Lot#:
To conform with the 2008 Oregon Residential Specialty Code(ORSC),Section R318.2 and
OAR 918480-0140,I am notifying the building official that!tun aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement
[Section R3I8.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes,the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
'
Signature: or Date: 10(7(a.0
Giniiir-A"Serractqf Ownor-Builder
OBssiktineforcatr-S-MouurreScoisttrowood do c 0925,)
—
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Pt No.: , , ....cow. luriUdicbon:
Site Addresa: kmewt aPV--
Subdivision/Len 4:
and/or
Map and Tax Lot#:
By my signature below,I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above manioned building have been ironalled with compact or
linear fluorescent,or a lighting source that has a minimums efficacy of 40 lumens per input watt.
(Oregon Resickntial Specialty Code N1107.2)1
1611 tlr)
Signature: 4- Date:
()weer I3 -CainractorfAirthoriied. Amu
Print Name: ./-1,A.
ORSC Section NI 107.2.High-efficiency nstenor lighting systems A.omen=of fely(S0)Parent 0 thc
permanently installed lighting futures shall Sc testalled with oonspact or linear fluorescent,or a lists:mg source thal
has a=um=efficacy of 40 lumens par input watt. Seraw-in compact fluorescent lamps comply with this
requirecosept
Me bunnies()friend shall be eoufiect in writing at the&al usspeoncen Mat a=nun=of fifty Meant of the
permanently mstallad bghtmg fixtures are compact or linear fluorescent,or a muntnum efficacy of 40 lumens per
input wart
siumeecrerswitEs-Hisbertioraretiarreatior oPoios
Moffet Energy Modeling
CCB#223372
Phone: 916-342-0742
tyler@moffetco.com
Blower Door Test Affidavit
Permit#: Builder: Taylor Morrison
Site Address: Eastridge Lot 62: 14229 SW 169th Ave,Tigard, OR 97224
Conditioned Floor Area (sq.ft.): 1838
Source: Calculated from plans Calculated Building Volume (cubic feet): 17780
TEST RESULTS: 1009 CFM @ 50 Pa
ACH @ 50 Pa = {(CFM x 60)÷Volume}: 3.40
Ring: Open 0 B
Minneapolis Blower Door and DG 700 Manometer
I certify that these building leakage rates are accurate and determined using standard BPI testing
protocol.
Company Name: Moffet Energy Modeling Technician: Tyler Moffet
Technician Signature: -7 *A 71 Date: 9/30/2020