Loading...
Report (5) Oregon Residential Specialty Code R408.1 MOISTURE BARRIER ACKNOWLEDGEMENT FORM am the general contractor or the owner-builder at the following address: Site Address: t-i3.01-C( SL-) k City: Permit#: Subdivision/Lot#: (44, and/or Map and Tax Lot#: To confordrwith the 2014 Oregon Residential Specialty Code(ORSC),Section R408.1 Ventilation.lam notifying the building official that I have installed the Moisture Barrier as per Requirement in ORSC Section 408.1 and have taken the following steps to meet this code requirement: [ The ground surface of the under-floor space is covered with 6-mil black polyethylene sheeting with DiCints lapped 12"at seams and [Ig•-xtending up the foundation walls 12". ' fp .7 7,0 Signature: ' Date: or Owner-Builder I 4iutldiostFone RES-Mouturil ariff doc !mole Oregon Residential Specialty Code R318.2 ------------ MOISTURE CONTENT ACICNOWLEDGEMENT FORM 't CA,\---• am the general contractor or the owner-builder at the follovving address: Site Address. t(47,1A Lts2C(b" A . City: .‘ Permit#: Subdivision/Lot#: and/or Map and"Tvx Lot#: To conform with the 2008 Oregon Residential Specialty Code(ORSC),Section R318.2 and OAR 918480-0140,I am notifying the building official that!tun aware of the moisture content Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement [Section R3I8.2 is provided for reference]. R318.2 Moisture Content: Prior to the installation of interior finishes,the building official shall be notified in writing by the general contractor that all moisture-sensitive wood framing members used in construction have a moisture content of not more than 19 percent by dry weight of dry framing members. ' Signature: or Date: 10(7(a.0 Giniiir-A"Serractqf Ownor-Builder OBssiktineforcatr-S-MouurreScoisttrowood do c 0925,) — Oregon Residential Specialty Code N1107.2 HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS Pt No.: , , ....cow. luriUdicbon: Site Addresa: kmewt aPV-- Subdivision/Len 4: and/or Map and Tax Lot#: By my signature below,I certify that a minimum of fifty(50)percent of the permanently installed lighting fixtures in the above manioned building have been ironalled with compact or linear fluorescent,or a lighting source that has a minimums efficacy of 40 lumens per input watt. (Oregon Resickntial Specialty Code N1107.2)1 1611 tlr) Signature: 4- Date: ()weer I3 -CainractorfAirthoriied. Amu Print Name: ./-1,A. ORSC Section NI 107.2.High-efficiency nstenor lighting systems A.omen=of fely(S0)Parent 0 thc permanently installed lighting futures shall Sc testalled with oonspact or linear fluorescent,or a lists:mg source thal has a=um=efficacy of 40 lumens par input watt. Seraw-in compact fluorescent lamps comply with this requirecosept Me bunnies()friend shall be eoufiect in writing at the&al usspeoncen Mat a=nun=of fifty Meant of the permanently mstallad bghtmg fixtures are compact or linear fluorescent,or a muntnum efficacy of 40 lumens per input wart siumeecrerswitEs-Hisbertioraretiarreatior oPoios Moffet Energy Modeling CCB#223372 Phone: 916-342-0742 tyler@moffetco.com Blower Door Test Affidavit Permit#: Builder: Taylor Morrison Site Address: Eastridge Lot 62: 14229 SW 169th Ave,Tigard, OR 97224 Conditioned Floor Area (sq.ft.): 1838 Source: Calculated from plans Calculated Building Volume (cubic feet): 17780 TEST RESULTS: 1009 CFM @ 50 Pa ACH @ 50 Pa = {(CFM x 60)÷Volume}: 3.40 Ring: Open 0 B Minneapolis Blower Door and DG 700 Manometer I certify that these building leakage rates are accurate and determined using standard BPI testing protocol. Company Name: Moffet Energy Modeling Technician: Tyler Moffet Technician Signature: -7 *A 71 Date: 9/30/2020