Loading...
Report Oregon Residential Specialty Code N1107.2 HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS Permit No.: As-c- — cDVA-CX4A2> Jurisdiction. _-- • Site Address: C__nPt-S*V Subdivision/Lot#: and/or Map and Tax Lot#: By my signature below, I certify that a minimum of fifty(50)percent of the permanently installed lighting fixtures in the above mentioned building have been installed with compact or linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt. (Oregon Residential Specialty Code N1107.2)1 Signatur : Agent Date: (a/I ti/ )to- tractor/Authoriled Print Name: ORSC Section N1107.2.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that has a minimum efficacy of 40 lumens per input watt Screw-in compact fluorescent lamps comply with this requirement. The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per input watt 1:\BuildingWorms\RES-liighEfficiencyLighting.doc 07/01/08 Oregon Residential Specialty Code R408.1 MOISTURE BARRIER ACKNOWLEDGEMENT FORM I, , am the general contractor or the owner-builder at the following address: Site Address: City: Permit#: Subdivision/Lot#: kk Cc) and/or Map and Tax Lot#: To conform with the 2014 Oregon Residential Specialty Code(ORSC), Section R408.1 Ventilation.I am notifying the building official that I have installed the Moisture Barrier as per Requirement in ORSC Section 408.1 and have taken the following steps to meet this code requirement: The ground surface of the under-floor space is covered with 6-mil black polyethylene sheeting with DiOints lapped 12"at seams and rq-EXtending up the foundation walls 12". f Date: (.0/0fr) or Owner-Builder IABuildineForm\RES-MoistureBarrier.doc 09/13/2016 Oregon Residential Specialty Code R318.2 MOISTURE CONTENT ACKNOWLEDGEMENT FORM , am the general contractor or the owner-builder at the following address: Site Address: City: Permit#: Subdivision/Lot#: t\Co and/or Map and Tax Lot#: To conform with the 2008 Oregon Residential Specialty Code(ORSC), Section R318.2 and OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement. [Section R318.2 is provided for reference]. R318.2 Moisture Content: Prior to the installation of interior finishes,the building official shall be notified in writing by the general contractor that all moisture-sensitive wood framing members used in construction have a moisture content of not more than 19 percent by dry weight of dry framing members. Signatum: _ N71 Date: ctn;or Ovvner-Builder I:\Buildineform\RES-MoistureScuitiveWooct.doc 09/25/08 Moffet Energy Modeling CCB#223372 Phone:916-342-0742 tylerPmoffetco.com Blower Door Test Affidavit Permit#: Builder: Taylor Morrison Site Address: Roshak Lot 116: 14218 SW Gold Coast Terrace,Tigard,OR 97224 Conditioned Floor Area (sq. ft.): 1838 Source: Calculated from plans Calculated Building Volume (cubic feet): 17780 TEST RESULTS: 1193 CFM @ 50 Pa ACH @ 50 Pa = {(CFM x 60)_Volume}: 4.03 Ring: Open O B Minneapolis Blower Door and DG 700 Manometer I certify that these building leakage rates are accurate and determined using standard BPI testing protocol. Company Name: Moffet Energy Modeling Technician:Tyler Moffet Technician Signature: Date: 6/16/2020