Report (91) Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
, am the general contractor or the owner-builder
at the following address:
Site Address:
IL\ D c)(-6 173-12. 2_,
City
Permit#:
t'A a-O\et -9-01
Subdivision/Lot#: t
and/or
Map and Tax Lot#:
To conform with the 2008 Oregon Residential Specialty Code(ORSC), Section R318.2 and
OAR 918480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes, the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Signatu6: -(1) r
Date: 62-7 SVALD"GeW(ratintra.ct,oi or Chvner-Builder
1:\BuildingTorm\RES-MoistureSensitiveWood.doc 09/25/08
. _
Oregon Residential Specialty Code N1107.2
HIGH—EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: Jurisdiction.
'
Site Address: 14-0
Subdivision/Lot#:
and/or
Map and Tax Lot#:
By my signature below, I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code N1107.2)1
Signatur . Date: LA/
tractor/A Agent
Print Name:
ORSC Section N1107.2.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that
has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this
requirement.
The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or lini-Ar fluorescent,or a minimum efficacy of 40 lumens per
input watt.
\Building\Forms\RES-HighEfficiencyLighting.doc 07/01/08
Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
s , am the general contractor or the owner-builder
at the following address:
Site Address:
l SL3 C__C_1( 1-S -0.3.1241_
City:
t Permit#:#: -
Subdivision/Lot#:
t
and/or
Map and Tax Lot#:
To conform with the 2014 Oregon Residential Specialty Code(ORSC), Section R408.1
Ventilation.I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
r-M1'<-he ground surface of the under-floor space is covered with 6-mil black polyethylene
sheeting with
[ }its lapped 12"at searns and
1.--4tending up the foundation walls 12".
Signature Date: 61./I
or Owner-Builder
1:V3ui1dinifform\RES-MoistureBarriendoc 09/13/2016
Moffet Energy Modeling
CCB#223372
Phone: 916-342-0742
tyler@moffetco.com
Blower Door Test Affidavit
Permit#: Builder: Taylor Morrison
Site Address: Roshak Lot 115: 14220 SW Gold Coast Terrace,Tigard,OR 97224
Conditioned Floor Area (sq. ft.): 1554
Source: Calculated from plans Calculated Building Volume (cubic feet): 14970
TEST RESULTS: 1008 CFM @ 50 Pa
ACH @ 50 Pa = {(CFM x 60)_Volume}: 4.04
Ring: Open DA B
Minneapolis Blower Door and DG 700 Manometer
I certify that these building leakage rates are accurate and determined using standard BPI testing
protocol.
Company Name: Moffet Energy Modeling Technician:Tyler Moffet
Technician Signature: Date: 6/12/2020