Report (5) Oregon Residential Specialty Code N1107.2
IIIGII-EFFICIENCY INTERIOR LIGIITING SYSTEMS
Permit No.: V\ST- apk.a --O094S' Jurisdiction:
Site Address: ki-tP.Sek k ct:c1 A-0-t_
Subdivision/Lot#: LA
and/or
Map and Tax Lot#:
By my signature below, I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code N1107.2)I
Signature:
Date: (.51//Si79•L
tractor/Authorid Agent
Print Name: .
1 ORSC Section N1107.2.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that
has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this
requirement.
The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per
input watt.
I:\Buil&giForms1RES-HighEfficiencyLighting.doc 07/01/08
•
Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
I, A-AA/ , am the general contractor or the owner-builder
at the following address:
Site Address: 11_4 ck u_c2. c01.-..
City:
Permit#:
Subdivision/Lot#:
and/or
Map and Tax Lot#:
To conform with the 2014 Oregon Residential Specialty Code(ORSC), Section R408.1
Ventilation. I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
RThe ground surface of the under-floor space is covered with 6-mil black polyethylene
sheeting with
EIT-0-:ints lapped 12"at seams and
EqEl-ctending up the foundation walls 12".
--
Signatut Date: Cf2 It 51 9-0
uethrg or Owner-Builder
LkBuildingTorm1RES-MoistureBarriendoc 09/13/2016
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
L , am the general contractor or the owneT-builder
at the following address:
Site -
Address. ILI,
City:
Permit#:
Subdivision/Lot#:
and/or
Map and Tax Lot#:
To conform with the 2008 Oregon Residential Specialty Code(ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes, the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Signatu Date: te27t
or Owner-Builder
I:\Buildinifform\RES-MoisturcSensitiveWood.doc 09/25/08
Moffet Energy Modeling
CCB#223372
Phone: 916-342-0742
tyler@moffetco.com
Blower Door Test Affidavit
Permit#: Builder: Taylor Morrison
Site Address: Roshak Lot 64: 14239 SW 169th Ave,Tigard,OR 97224
Conditioned Floor Area (sq. ft.): 1554
Source: Calculated from plans Calculated Building Volume (cubic feet): 14970
TEST RESULTS: 1030 CFM @ 50 Pa
ACH @ 50 Pa = {(CFM x 60)-Volume): 4.13
Ring: Open DA B
Minneapolis Blower Door and DG 700 Manometer
I certify that these building leakage rates are accurate and determined using standard BPI testing
protocol.
Company Name: Moffet Energy Modeling Technician:Tyler Moffet
Technician Signature: 7
yot �r %� Date: 6/12/2020