Report Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: S 161 , oD 7S Jurisdiction: k9
Site Address: ( tAi I Coq /906
Subdivision/Lot#: - a 3
and/or
Map and Tax Lot#:
By my signature below, I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code N1107.2)1
Signature: (jCo 4 Date: 9- v
Owner/General Contractor/Authorized Agent
Print Name:
1 ORSC Section N1107.2.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that
has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this
requirement.
The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per
input watt.
I:\Building\Fomu\RES-HighEfficiencyLighting.doc 07/01/08
Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
, am the general contractor or the owner-builder
at the following address:
Site Address: / £ 35-2 ( 69 'd QUe-
City: , �f
4J
Permit#: Ps 090 rj - OD? ',—
Subdivision/Lot#: Co-f ?j
and/or
Map and Tax Lot#:
To conform with the 2014 Oregon Residential Specialty Code(ORSC), Section R408.1
Ventilation.I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
7/ The ground surface of the under-floor space is covered with 6-mil black polyethylene
sheeting with
Joints lapped 12"at seams and
Extending up the foundation walls 12".
Signature: Lp VJ' Date: 9 - q -p0d fl
General Contractor or Owner-Builder
I:\Building\Ponn\RES-MoistureBarrier.doc 09/13/2016
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
I, ` 01/a , am the general contractor or the owner-builder
at the following address:
Site Address: ( q 3 c' S j / A4)6
City:
Permit#: 1/111 S.T— /9 1 00
Subdivision/Lot#: j-f-
and/or
Map and Tax Lot#:
To conform with the 2008 Oregon Residential Specialty Code(ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes,the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
- v-202,9
Signature: k ' Date:
General Contractor or Owner-Builder
I:\Building\Form\RES-MoistureSensitiveWood.doc 09/25/08
Form 640S 2017
Completion Certification—Site Inspection
EnerRyTrust
New Homes Program—Single Family
of Oregon
To be completed by Verifier
CLEAResult is a Program Management Contractor for Energy Trust of Oregon,Inc.
Payment information
Incentive Payee Company Name: 'William Lyon Homes Its this payment redirected?: INo
Builder or Company: William Lyon Homes Redirect to Name:
Verifier Payee Company Name: Performance Insulation and Energy Redirect Payee Corn
Affordable Housing No
Solar Ready Builder Incentive: jSolar ReadyVerifier Inc('
Site Information
Development: River Terrace Rowshack 'Lot 123 Axis ID: I 'REM/Rate®ID:
Address: 14352 SW 169TH AVE
Street Line 2 Mul6-Family INo City: BEAVERTON State: OR Zip: 97007
Total conditioned area(sq.ft.). 1,730 House Volume: I 15,828 Housing Type: Detached single family
Number of Stories: 12 Number of Bedrooms. 4 Foundation Type: Crawlspace
Electric Provider: Portland General Electric Gas Provider: INW Natural Gas
Solar installed Solar Installer Name/Company: II
Blue shaded fields are required for EPS sheet
Verification Type Actual Model Equipment Details&Notes
Slab Perimeter Insulation R- 0.0 Slab Under Insulation R-
Framed Floor R- 30.0 Secondary Framed Floor R- 59.0
Insulation
Above Grade Wall Insulation R- 23.0 Below Grade Wall Insulation R-
Flat Ceiling Insulation R- 49.0 Vaulted Ceiling Insulation R- 38
Windows Windows U- 0.3 SHGC:I0.3 Total window area: I207
Cooling Air Conditioning SEER: 0 Model#:
Primary Heating System Details AFUE: 95 Brand Lennox
Type: Gas Furnace HSPF: Model#: ML196UH045XE36B-51
Heating Fuel: Gas SEER:
Primary Heat
Source Comment: COP:
Location: Conditioned A Outdoor Unit(for heat pumps)
ECM: No Model#: I
AHRI Certificate:4805339 #of Systems 11
Gallons: 166 Brand: AOSmith
Water Heater Type Heat Pump EF: 13.17 Model#: HPTU-66N 130
Water Heating Fuel Electric Location: 'Garage or opu AHRI Certificate:
Ducts and Duct Location 'Conditioned %ducts inside: 195% 'rlDuct Leakage(CFM)@ 50Pa: I100
Testing
Infiltration Air Changes per Hour(ACH)@ 50Pa: 3.01 I
Ventilation Type HRV/ERV Model:
Ventilation --
Supply Side-Air Cycler Airflow measured or why untestable? 'Roof Termination
Appliances
Refrigerator kWhlyr Model:
ENERGY STAR Diswasher kWhlyr 270 Model: GDT60"*M"—
Percent High Efficacy Interior Lighting(%) 100% Thermostat
Showerhead 1.5 GPH I Showerwand 1.5 GPH ' Showerhead 1.6 GPH I IShowerhead 1.75 GPH I
Notes: