Loading...
Report P4; sW Caddy ,I tis'Irp30-00770 Bend Office (541) 330-9155 Geotechnical Office (503) 601-8250 Carlson Testing, Inc. Eugene Office (541) 345-0289 Salem Office (503) 589-1252 Tigard Office (503) 684-3460 Daily Report of Proprietary Anchors Client: ROGUE REMODEL - DAVIS STONE Project: KELLY CORLL RESIDENCE CTI Job#: T2103076. Address: 13303 SW CADDY PLACE TIGARD OR Jurisdiction: TIGARD CTI representative J. VIALPANDO WABO SI 02254/ACI 01538462 was on site this date Jan. 15, 2021 to perform Special Inspection for: Permit MST2020-00270 DFS #(s) PO Number: KELLY SCOPE OF INSPECTION Location of proprietary anchors inspected [to include grid lines, elevations (floors) and drawing details]: 1. Checked in with superintendent or client representative. Name: DAVIS STONE WITNESSED THE INSTALLATION OF 4 5/8 THREADED ROD Com an ROGUE REMODEL 3 WITH 9" EMBED 1 WITH 13" EMBED AND 6 1/2 TITEN p y HD ON THE NORTH AND SOUTH WALLS OF NEW BEDROOM 2. Inspection was "IBC" Continuous x Periodic AS PER 1/P-2 GARAGE LEVEL PLAN PROPRIETARY ANCHORS YesNoN/A 1. Reviewed previous inspection reports? x 2. Reviewed evaluation report? x Verified following items meet manufacturer's published installation instructions. REPORT SUMMARY 3. Verified minimum embedment depth of the anchors. x 1. Work inspected was: Completed x In progress 4.Verified installation of the anchors. X 2. Work inspected in progress was in compliance with 5. Verified anchor diameter. X R Approved plans and specifications n Shop drawings 6. Verified steel grade. x 7. Verified hole diameter. ❑ RFI Design change Submittal N/A X 8. Verified type of drill bit used. x Document #(s) SITE PLANS Dated: 12-04-2020 9. Verified hole cleaning method. X 3. Noncompliance item(s) were noted this date, details on 10. Verified adhesive application. X following page(s). n Yes ❑ No El N/A 11. Verified edge distance. x 12. Verified spacing. 4. Noncompliance item(s) were reinspected this date, details p g. X on following page(s). Yes I I No I x I N/A 13. Verified installation torque. PI Conform E. Remain in progress Evaluation report number & date: ESR 2508 7/20 - 7/21 Report(s) findings were discussed and left with ESR 2713 1/21 - 9/21 DAVIS STONE of ROGUE REMODEL Name of product being installed SIMPSON SET XP & TITEN HD Batch Number 1000113866 Expiration Date 2022-11-22 Based on the Code, approval is required from the Building Official before the SPECIAL INSPECTED items noted above can be covered. Carlson Testing has no authority to direct work of contractors or subcontractors. See additional report page(s). n Distribute attachments. Page 1 of 2 Daily Report of Proprietary Anchors For: 01/15/2021 CTI Job#: T2103076. Project: KELLY CORLL RESIDENCE Notes: In some cases more than one box may be checked for a given item on the front page. Our reports pertain to the material tested/inspected only.Information contained herein is not to be reproduced,except in full, without prior authorization from this office.Under all circumstances,the information contained in this report is provided subject to all terms and conditions of CTI's General Conditions in effect at the time this report is prepared.No party other than those to whom CTI has distributed this report shall be entitled to use or rely upon the information contained in this document. If there are any further questions regarding this matter,please do not hesitate to contact this office. Respectfully submitted, CARLSON TESTING,INC. Johnny Johnson Reviewed By:Project Manager Project Manager Review Date:01/15/2021 JV/JV CC: ROGUE REMODEL - DAVIS STONE ROGUEREMODEL@OUTLOOK.COM • CITY OF TIGARD BUILDING DIVISION - WALTER 'CHIP' BARNETT FINAL/NCL ONLY DELTA STUDIOS ARCHITECTURE AND PLANNING LLC OREGONARCHITECT@HOTMAIL.COM PROPERTY DAMAGE SOLUTIONS LLC (PDS) - CHRIS NESTLERODE CHRIS@PDSLLCNW.COM ROGUE REMODEL - DAVIS STONE ROGUEREMODEL@OUTLOOK.COM KELLY CORLL KCORLL@COMCAST.NET 8430 SW HUNZIKER ST,TIGARD OR-PO BOX 230997,TIGARD OR 97281 Page 2 of 2