Report M' 249-
/►�� HCE
Horn Consulting Engineers LLC
1b,
Special Inspection Report 4- ; avas
r _
To: Brian Nathman
From: David J. Horn
Date: 2/17/2021 t �y
Re: 14988 SW Lookout Dr. Tigard, OR
2-13-18:
• Performed Special Inspection via Facetime
• Intent of inspection was for the installation of 2- 5/8" diameter A36 threaded rod epoxy embeds with
an embedment depth of 12"
• Temperature at the time of installation was approximately 65 degrees (work was performed inside
the house) Fahrenheit.
• Simpson Set-XP10 epoxy was used. Expiration 10/06/2022 Lot 1000107665
• Verified holes for diameter, depth, and cleanliness.
• Installation of anchors appeared to be per the plans and design intent.
This report pertains to the material tested / inspected only. Information contained herein is not to be
reproduced, except in full, without prior authorization from this office.
7412 SW Beaverton-Hillsdale Hwy, Ste 202 Portland, OR 97225
Phone: 503.892.5782 Email: dave@a hornce.corn