Loading...
Report M' 249- /►�� HCE Horn Consulting Engineers LLC 1b, Special Inspection Report 4- ; avas r _ To: Brian Nathman From: David J. Horn Date: 2/17/2021 t �y Re: 14988 SW Lookout Dr. Tigard, OR 2-13-18: • Performed Special Inspection via Facetime • Intent of inspection was for the installation of 2- 5/8" diameter A36 threaded rod epoxy embeds with an embedment depth of 12" • Temperature at the time of installation was approximately 65 degrees (work was performed inside the house) Fahrenheit. • Simpson Set-XP10 epoxy was used. Expiration 10/06/2022 Lot 1000107665 • Verified holes for diameter, depth, and cleanliness. • Installation of anchors appeared to be per the plans and design intent. This report pertains to the material tested / inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. 7412 SW Beaverton-Hillsdale Hwy, Ste 202 Portland, OR 97225 Phone: 503.892.5782 Email: dave@a hornce.corn