Loading...
Report m41100 00/03 Oregon Residential Specialty Code R318.2 MOISTURE CONTENT ACKNOWLEDGEMENT FORM , am the general contractor or the owner-builder at the following address: Site Address: (-tt-t(-11 3 61°.1-b 174e.a__ City: Permit#: 11/4-A 7./.0ar->60(_0()) Subdivision/Lot#: and/or Map and Tax Lot#: To conform with the 2008 Oregon Residential Specialty Code(ORSC), Section R318.2 and OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement. [Section R318.2 is provided for reference]. R318.2 Moisture Content: Prior to the installation of interior finishes,the building official shall be notified in writing by the general contractor that all moisture-sensitive wood framing members used in construction have a moisture content of not more than 19 percent by dry weight of dry framing members. Signature: I Date: S113/A1 ie ••.1:ctjo or Owner-Builder I:\BuiidingWorm\RES-MoistureSensitivewood.doc 09/25/08 Oregon Residential Specialty Code R408.1 MOISTURE BARRIER ACKNOWLEDGEMENT FORM I, 6, -., L► .•.r- 5 , am the general contractor or the owner-builder at the following address: Site Address: City: Permit#: t.")\5 -C ld' Subdivision/Lot#: and/or Map and Tax Lot#: To conform with the 2014 Oregon Residential Specialty Code(ORSC), Section R408.1 Ventilation. I am notifying the building official that I have installed the Moisture Barrier as per Requirement in ORSC Section 408.1 and have taken the following steps to meet this code requirement: e ground surface of the under-floor space is covered with 6-mil black polyethylene sheeting with [E rots lapped 12"at seams and (-Ending up the foundation walls 12". Signatur I.i • Date: 5"1(3/A4 G •: ,:1 • �' • or Owner-Builder 1:ll3uiJding\F'orm\RES-Moist urBarrier.doc 09/13/2016 Oregon Residential Specialty Code N1107.2 HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS Permit No.: i c)DkC3 Jurisdiction: Site Address: 143'31-4 SL ) LaA-%V ' t_ Subdivision/L,ot#: C1 and/or Map and Tax Lot#: By my signature below, I certify that a minimum of fifty(50)percent of the permanently installed lighting fixtures in the above mentioned building have been installed with compact or linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt. (Oregon Residential Specialty Code N1107.2)1 " Signature: lmom Date: S1 /X.1 __. 4'1" +tractor/Authorized Agent s • Print Name: ,,-,LA, c.� � A A c, ORSC Section N1107.2.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this requirement. The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per input watt. I:\BuildineForms\RES-HighEfficiencyLighting.doc 07/01108 clowisor ) . V.WALa. 6s .NS�Jt-,..-c Certificate of Compliance . This document certifies that the fiberglass insulation has been installed in conformance with the manufacturer's recommendations and requirements to provide thermal resistance value(s)of: R-value Thickness Coverage Area Ceilings: R-49 X New Construction Vaults/Slopes: Walls: in Upgrade Blown in R-23 Rim Joist: Floors: Over Garage R-38 Crawl Vapor Barrier installed_Y _N Sprinkler Tenting 4 mil Poly x Y _N Loose-Fill Insulation R-49 using bags of insulation to cover 576 square feet of area at a thickness of 16.75 inches. Owens Corning`PROPINK"L77 Loosefill Insulation Owens Corning will accept no responsibility when the product is not installed in accordance with the product label.Stated R-value is provided by installing the required number ofbags at a thickness not less than the labeled minimum thickness.Installation of the required number ofbags may yield more than the specified minimum thickness.Failure by the installer to provide both the required bags and at least the minimum thickness will result in lower insulation R-value. R-VALUE BAGS PER MAXIMUM NET MINIMUM WEIGHT MINUMUM 1000 SQ.FT. COVERAGE PER SQ.FT. THICKNESS To obtain a No.of bags per 1000 sq. Contents of this bag Weight per sq.ft.of Installed insulation thermal resistance ft.of net area: should not cover installed insul.should should not be less (R)of: more than:(sq.ft.) not be less than:(lbs.) than:(in.) 60 28.0 35.8 0.895 20.00 49 22.2 45.0 0.711 16.75 44 19.7 50.7 0.631 15.00 38 16.7 59.9 0.534 13.25 30 13.0 77.0 I 0.416 10.50 26 11.2 89.6 I 0.357 9.25 22 9.4 106.3 I 0.301 8.00 19 8.0 125.0 I 0.256 7.00 13 5.4 184.6 I 0.173 4.75 Property Address: 14344 SW Gold Coast Terrace Lot 99. Tigard. OR 3/06/21 Carolina Jarquin Date of Installation thorization 5/04/21 Today's Date Signature Taylor Morrison Company/Customer Name P.O.BOX 99*HUBBARD,OR 97032*(503)620-7036*FAX(503)624-0599*CCB#71044