Report (4) Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
I+ (� 3 l�- ,..,. , am the general contractor or the owner-builder
at the following address:
Site Address: 4 Z 4 3 $'..) r+.
1 la<{ Q-u c
City:
Permit#: �L n `J . ->E el_c e
Subdivision/Lot#: -10
and/or
Map and Tax Lot#:
To confonirWith the 2014 Oregon Residential Specialty Code(ORSC),Section R408.1
Ventilation.I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
Effie ground surface of the under-floor space is covered with 6-mil black polyethylene
sheeting with
plaints lapped 12"at seams and
[ ctending up the foundation walls 12".
Signature: — t
Date: t ‘t Lv
Ersergi or Owner-Bunder
I.\8%WoofonedREES-Moutuet a*+Q.doe 09/13/2016
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
. v c-- y ` , am the
general contractor or the owner-builder
at the following address:
Site Address: .L
(Cad ` 4,,,
City:
Permit#:
IL-V-�: .Xo\a-o83,).(a
Subdivision/Lot ifit O
and/or
Map and"'a Lot#:
To conform with the 2008 Oregon Residential Specialty Code(ORSC),Section R318.2 and
OAR 918-480-0140,I am notifying the building official that I am aware of the moisture content
Requitement of ORSC Section R3181 and have taken steps to meet this code requirement
[Section R318.2 is provided for reference].
R318.2 Moisture Content. prior to the installation of interior finishes,the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood flaming members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Signature: 111
I.VitoOdarfo,mUttS-MnyiortSmom voWood.doc 0929E4
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: , Jurisdiction: ,
16t.-(..)( Sd•-(Jo
. C
Site Address: t 4•Ct
Subdivision/Lat#: c
and/or
Map and Tax It#:
By my signature below,I certify that a minimum of fifty(50)percent of the pamaneady
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent,or a lighting source that has a minimum efficacy of 40 hmacns pa input watt.
(Oregon Residential Specialty Code N1107i)'
,
Signature: Date: 11" (V)
Ovese6;14CottracaoriAmbonied Agent
Print Name:
ORSC seams NI'07.2 High-efficiency tremor aortas systems A men of fifty(30)perreat o the
permanently metalled lightms fixtures shall be assialled with compact or imasr thamoscata,or a tighting source that
has a minimum efficacy of 40 lumens per input van SCTOW-in mama fluorement Imps compty with this
requirement
the buskin*official shall be Daubed ta vmunit at die final inspection that a nuanaum of fifty percent of the
permanently metalled lightms futures are compact or linear fluorescent,or a man=offgary of 40 lumens per
input watt
IkakidivrtanwARES4410ElSomeyLiallertg.doc 07,01e)
Moffet Energy Modeling
CCB#223372
Phone: 916-342-0742
tyler@moffetco.com
Blower Door Test Affidavit
Permit#: Builder: Taylor Morrison
Site Address: Roshak Lot 70: 14293 SW 169th Ave,Tigard, OR 97224
Conditioned Floor Area (sq.ft.): 1406
Source: Calculated from plans Calculated Building Volume (cubic feet): 13450
TEST RESULTS: 1030 CFM @ 50 Pa
ACH @ 50 Pa = {(CFM x 60)-Volume}: 4.59
Ring: Open O B
Minneapolis Blower Door and DG 700 Manometer
I certify that these building leakage rates are accurate and determined using standard BPI testing
protocol.
Company Name: Moffet Energy Modeling Technician: Tyler Moffet
Technician Signature: Date: 11/10/2020