Report (4) ........ ............. .... .. ... .....Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
tc . , am the general contractor or the owner-builder
at the following address:
Site Address.
tell Sk-.1 I La Ct%h•
City:
k ec„, y--
Permit#: -0032:1
Subdivision/Lot#:
t
and/or
Map and Tex Lot#:
To conform with the 2008 Oregon Residential Specialty Code(ORSC),Section R3182 and
OAR 918-480-0140,I am notifying the building official oe content
Requirement of ORSC Section R318.2 arid have talcen steps to meet this code requirement
(Section R318/is provided for ic=mice).
R318.2 Moisture Content: Prior to the installation of interior finishes,the builetinE
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Signaling:
e ,'•"411. •. • or Chrocr-auild. Date: 1" (g.eg>
1 likuktsarf armaLS-MautureSteauvoWood do 09,23AJI
Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
I, j , am the general contractor or the owner-builder
at the following address:
Site Address: Z.CVA W.., Let Au-0•e—
City:
Permit#:
Subdivision/Lot#:
and/or
Map and Tax Lot#:
To conforewith the 2014 Oregon Residential Specialty Code(ORSC),Section R408.1
Ventilation,lam notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
alit ground surface of the under-floor space is covered with 6-mil black polyethylene
sheeting with
[Thiiints lapped 12"at seams and
Dfitending up the foundation walls 12".
Sigaat /
ure: • Date: 1 11
,r4,or Cnvner-Btulder
t 4huldingTomORES-Motatiel arnar doe 09/t 3/2 o 6
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit NO
- t:4-)41•1 Jurisdiction:
I •
— -
Site Address:
14 Z.Cti 443-e—
Subdivisionlot Or:
and/or
Map mind Tax Lot a:
By my signanae below,I certify that a minimum of fifty(SO)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent,or alighting sowce that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code NI 107.2)1
Date: "tit IX°
Signanne: -
s'lKraltatnractori.sinhnrissit
Print Name: ri ,
'MSC Samoa N1107.2.High-efficiency intenor bighting iyaion A=um=of fifty(50)percent o the
permosofty aweened hetung fixtures shall be sonalled with compact or Linear Onorescans„or a lighting source thai
hen e swieememe efficacy of 40 humans per toper watt. Screwio ocenpect thiorowent lamps comply with this
requiveleet
The leribbeg edhied ilea be atitiffed bi writing at the final inspecnon that a minimum of fifty percent of the
pummildy assaid hiOgig axons ire sompact or haw fluorescent,or•ailanallin efficacy of 40 lumens per
opet gem
abeitliwpftworielleialegilebbewiteliimealte mem
Moffet Energy Modeling
CCB#223372
Phone: 916-342-0742
tyler@moffetco.com
Blower Door Test Affidavit
Permit#: Builder: Taylor Morrison
Site Address: Roshak Lot 71: 14297 SW 169th Ave,Tigard,OR 97224
Conditioned Floor Area (sq.ft.): 1649
Source: Calculated from plans Calculated Building Volume (cubic feet): 15750
TEST RESULTS: 1251 CFM @ 50 Pa
ACH @ 50 Pa = {(CFM x 60)_Volume}: 4.77
Ring: Open DA B
Minneapolis Blower Door and DG 700 Manometer
I certify that these building leakage rates are accurate and determined using standard BPI testing
protocol.
Company Name: Moffet Energy Modeling Technician: Tyler Moffet
Technician Signature: .7 1rot7,44
Date: 11/10/2020
)
l