Report (4) Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
�� a /� a S , am the general contractor or the owner-builder
at the following address:
Site Address: (L k 4
.1 q Sw 1 LAC(` .45y�,
City:
t�1r
Permit#:
Subdivision/Lot#: to q
and/or
Map and Tax Lot#:
To conforrfl'with the 2014 Oregon Residential Specialty Code(ORSC),Scc.tion R408.1
Ventilation.I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this rndr
requirement:
{ The ground surface of the under-floor space is covered with 6-mil black polyethylene
sheeting with
�oints lapped 12"at seams and
ding up the fonnd.tion walls 12".
rl ( i
Signature: ` •} aim Date: "1�u (Lt?
.'YT or Owner-Builder
tiu r iaisoa aveks Mauna rrlr.doc 0A1Y2Ar6
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
, am the general contractor or the owner-builder
at the following address:
Site Address: , L-,K
bw l(A q z Aw-C—
---
Permit#:
c.)o3Z
Subdivision/Lot#: Ci
and/or
Map and'^ax Lot#:
To conform with the 2008 Oregon Residential Specialty Code(ORSC),Section R318.2 and
OAR 918-480-0140,I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes,the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Signature. Date: ut+�•�
Gcirc .�_.
c�a Unnt you Ow;�u 13 der !
1.VBWidmrFormitES-MaistcrSmim WWooa doe 0925438
. . .
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No
t ' 'ket-Ob13-5"
Jurisdiction: ----
Site Addressz
Sk-,) ci 114 A—u 4.—
‘t-11.1.ck
Subdivision/Lot*V
• Co
and/or
Map and Tax Let
By my signanne below,I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above mullioned building have been installed with compact or
linear fluorescent,or a lighting source that has a minimum efficacy of 40 lumens per input watt
(Oregon Residential Specialty Code NI 1072)1
Signature: _ Date: f
i_lwrie- tabizseterfAuthorated Ayes
Print Name: ,
ORSC Season NI 107.2.High-efficiency interior lighting systems A mminium of fifty(50)percent o the
permanently metalled lighting fames shall be installed with compact or lama fluorescent,or a liahnna source that
has a innumuns efficacy of 40 lumens pa input welt Sanw-in compact fluorescent lamps comply with this
requiranent
The b1S adtlead dna ba wafted to writing at the final inspection that a minimum of tiny pertain of the
pemoommilly Vatats*tures are compact or linear fluorescent,or a unonnum refi,acy of 40 lumens pa
split pm
Lvb4ftev1mmoia141011060.44~pc(Ivo vs
1
Moffet Energy Modeling
CCB#223372
Phone: 916-342-0742
tyler@moffetco.com
Blower Door Test Affidavit
Permit#: Builder: Taylor Morrison
Site Address: Roshak Lot 69: 14279 SW 169th Ave,Tigard,OR 97224
Conditioned Floor Area (sq.ft.): 1406
Source: Calculated from plans Calculated Building Volume (cubic feet): 13450
TEST RESULTS: 1050 CFM @ 50 Pa
ACH @ 50 Pa = {(CFM x 60)_Volume}: 4.68
Ring: Open 0 B
Minneapolis Blower Door and DG 700 Manometer
I certify that these building leakage rates are accurate and determined using standard BPI testing
protocol.
Company Name: Moffet Energy Modeling Technician: Tyler Moffet
Technician Signature: 7 l' "" Date: 11/10/2020