Report Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
I, , am the general contractor or the owner-builder
at the following address:
Site Address:
City:
Permit#: . - �`L� 60
Subdivision/Lot#: `
and/or
Map and Tax Lot#:
To conform with the 2008 Oregon Residential Specialty Code(ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes,the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Signature: ,F ) Date: - ( -
-ben—ral Contractor or Owner-Builder
1:\Building\Form\RES-MoistureSensiliveWood.doc 09/25/08
• •
Oregon Residential Specialty- Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
am the general contractor or the owner-builder
at the following address:
Site Address:
City:
G
Subdivision/Lot#: \
and/or
Map and Tax Lot#:
To conform with the 2014 Oregon Residential Specialty Code (ORSC), Section R408.1
Ventilation. I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
7 The ground surface of the under-floor space is covered with 6-mil black polyethylene
sheeting with
Joints lapped 12"at seams and
(TBxtending up the foundation walls 12".
Signature: __ Date: COH
Co trador"or Owner-Builder
I:1Building\Fonn\RES-MoistureBarrier.doc 09/13/2016
Oregon Residential Specialty Code N1107.2
111G11-EITICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: Jurisdiction:
aST-4.OR-004-CDC
Site Address:
Subdivision/Lot#:
\ , -
and/or
Map and Tax
By my signature below, I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent,or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential S "alty Code NI107.2)1
Signature: Date: (..5- 4-6
Contractor/Authoriz AgenTt
Print Name:
ORSC Section N1107.2.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that
has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this
requirement
The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per
input watt.
INBauldingTorms\RES-HighEfficiencyLighting.doc 07/0 MS
Moffet Energy Modeling
CCB#223372
Phone: 916-342-0742
tyler@moffetco.com
Blower Door Test Affidavit
Permit#: Builder: Taylor Morrison
Site Address: Roshak Lot 113: 14228 SW Gold Coast Terrace,Tigard, OR 97224
Conditioned Floor Area (sq.ft.): 1554
Source: Calculated from plans Calculated Building Volume (cubic feet): 14970
TEST RESULTS: 1014 CFM @ 50 Pa
ACH @ 50 Pa = {(CFM x 60) _Volume}: 4.06
Ring: Open oA B
Minneapolis Blower Door and DG 700 Manometer
I certify that these building leakage rates are accurate and determined using standard BPI testing
protocol.
Company Name: Moffet Energy Modeling Technician: Tyler Moffet
Technician Signature: Date: 5/29/2020
I1