Report ........................_........... ........ . . _ .
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
No •
P 't...errtu •. k,..ke,..)-c-- co,Let..... ocouto Jurisdiction: ---
Site Address: tut k CM StA) C_-144...b. C-CA-S%-- laigA-C4-;
Subdivision/Lot#:
lX\
and/or
Map and Tax Lot#:
By my signature below, I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code N1107.2)1
J.. 'Signature: 1-
......_, Date:
, tractor/Authorilecl Agent
...,.„.
Print Name:
1 ORSC Section N1107.2.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that
has a minimum efficacy of 40 lumens per input watt Screw-in compact fluorescent lamps comply with this
requirement
The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or linmr fluorescent,or a minimum efficacy of 40 lumens per
input watt,
I:\13uildingTonns\RES-HighEfficiencyLighting.doc 07/01/08
.....
Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
11,-.&\,-' , am the general contractor or the owner-builder
at the following address:
Site Address:
StA.) crASIF
City:
Permit#: "Y-C- _,) tc - boLiD,
Subdivision/Lot#:
and/or
Map and Tax Lot#:
To conform with the 2014 Oregon Residential Specialty Code(ORSC), Section R408.1
Ventilation. I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
Erfhe ground surface of the under-floor space is covered with 6-mil black polyethylene
sheeting with
'Ioints lapped 12"at seams and
MErctending up the foundation walls 12".
Signattu(
orOwner-Builder Date: 6757-C)
I:\BuildjForm\RES-MoistyjreBarrjetdoc 09/13/2016
..........._________
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
, am the general contractor or the owner-builder
at the following address:
Site Address:
Co A-sr 'V
City.
k 7k.
Permit#:
NAs .1,0 Let- oDDLIC)
Subdivision/Lot#:
and/or
Map and Tax Lot#:
To conform with the 2008 Oregon Residential Specialty Code(ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes, the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Signe*: Date: yV
to or Owner-Builder
IABuildiafform\RES-MoistureSensitiveWood.doc 092908
"if+iisffie a»iaae{HNM4fitHe[fa+iufeie++ Ye+ralnai. i ei+++ti+f twa utrai! r rn. ..+r ra+ i'+lMt##F11#tlittiNltiNWI#fu1 f fiFN1lL!}#i -.a.:.a.. - .rx+lsata '.ifi+iFil#eWNdHaiFt#iFti}4NtFi#iN#HA}iltdlltls6YMMF46MlHi#}ibtMWsbSiid4U' ux{eifu}{+uaui:.a-.
Moffet Energy Modeling
CCB#223372
Phone: 916-342-0742
tyler@moffetco.com
Blower Door Test Affidavit
Permit#: Builder: Taylor Morrison
Site Address: Roshak Lot 121: 14194 SW Gold Coast Terrace,Tigard, OR 97224
Conditioned Floor Area (sq.ft.): 1490
Source: Calculated from plans Calculated Building Volume (cubic feet): 15395
TEST RESULTS: 1015 CFM @ 50 Pa
ACH @ 50 Pa = {(CFM x 60)-Volume}: 3.96
Ring: Open O B
Minneapolis Blower Door and DG 700 Manometer
I certify that these building leakage rates are accurate and determined using standard BPI testing
protocol.
Company Name: Moffet Energy Modeling Technician: Tyler Moffet
Technician Signature: Date: 6/1/2020