Report ds
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
I, 4,t. c ( , am the general contractor or the owner-builder
at the following address:
Site Address: /��7 f $ Taaw7.l5vft.t-a
City:
Permit#: sra-0i c — 73
Subdivision/Lot#:
and/or
Map and Tax Lot#:
To conform with the 2017 Oregon Residential Specialty Code(ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes,the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry frami : members.
Signature: dit Date: 1 `1/?-oôZ
o 'ri uilder
I:\Building\Fo►m1RFS-MoistureContentAcknowledgement 022018
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: r15r2 o—00)/73 Jurisdiction: , 0
Site Address: l09c-
5,J �/.JxJStN 2.c_c- sr--
Subdivision/Lot#:
and/or
Map and Tax Lot#:
By my signature below, I certify that all of the permanently installed lighting fixtures in the
above mentioned building contain high-efficacy lamps. Screw-in compact fluorescent and LED
lamps comply with this requirement. (Oregon Residential Specialty Code N1107.2)1
Signature: f Date: � 4 Att
Cf /> /Authorized Agent
Print Name: l41-es (7 l GKrivi
'ORSC Section N 1107.2.High-efficacy lamps. All permanently installed lighting fixtures shall contain high-
efficacy lamps. Screw-in compact fluorescent and LED lamps comply with this requirement.
The building official shall be notified in writing at the final inspection that the permanently installed lighting fixtures
have met this requirement.
Exception: Two permanently installed lighting fixtures are not required to have high-efficacy lamps.
l:lBuilding\Forms\RES-HighEfficiencyLightingAcknowledgement_022018
Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
I, egotike6 ‘zterA-01 , am the general contractor or the owner-builder
at the following address:
Site Address: /4.7 c Si ''.J5 r l.LC
City:
Permit#: 15T 9-41/ — ob a r7 3
Subdivision/Lot#: 3�
and/or
Map and Tax Lot#:
To conform with the 2017 Oregon Residential Specialty Code(ORSC), Section R408.1
Ventilation. I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
^-� The ground surface of the under-floor space is covered by a Class I vapor retarder or
other approved materials,with
EA/Joints lapped 12 inches at seams and
Extending up the foundation walls 12 inches.
Signature: Date: 5l/rZ/2az d
eral or er-Builder
I:\Building\Form\RES-MoiistureBarrierAcknowiedgement 022018
Form 640S 2017
Completion Certification—Site Inspection F r- -•C4, s
New Homes Program—Single Family
oe Ofeton4
To be completed by Verifier
CLEAResult is a Program Management Contractor for Energy Trust of Oregon,Inc.
Payment information
Incentive Payee Company Name William Lyon Homes Its this payment redirected?: INS
Builder or Company: William Lyon:Homes
Redirect to Nama:
Verifier Payee Company Name: Performance insulation and Energy Redirect Payee Com
Affordable Housing No
Solar Ready Builder Incentive: jSolar ReadyVerdier lncr{
Site.Information
Development River Terrace Rowshecit Lot ( E
iiE1 , Axis ID- REM/Rated0 ID
�if
��,y,,W���WW�y, 66�E( Y ((( kt3 i E':iE:(• :•E o.. E _,a.••SEE
Address :kEREhriRft. E. ..E:E€EI€E€€�`�5,� ..��:EEiEi€(�E�...:I3iEt,s.e"'.`.�:." •��€€i€�: EEyijy
Street Line 2 Multi-Family No City: Beaverton :Slate: OR Zip: 97007
Total conditioned area(sq.ft.): 2,065I House Volume: I 18.495:Housing Type: Detached single family
Number of Stories: 12 :Number of Bedrooms: 4 Foundation Type: Crawlspace
Electric Provider: Portland General Electric Gas Provider: NW.Natural Gas
Solar installed Solar Installer Name/Company:
Blue shaded welds are required for EPS sheet
Verification Type - Acts*;.Model Equipment netats B,Notes
Slab Perimeter Insulation R- 0.0 Slab Under Insulation R-
Framed Floor R- 30.0 SecondaryFramed Floor R- 5 0
Insulation 9
Above Grade Wall Insulation R- 23.0 Below Grade Wall Insulation R-
Flat Ceiling Insulation R- 49.0 Vaulted Ceiling Insulation R-
Windows Windows U- 0.3 SHGC'0.3-:Total window area: 1314
Cooling Air Conditioning SEER: 0 Model#:
Primary Heating System Details AFUE: 92.1 Brand Bryant
Type: Gas Furnace HSPF: Model#: 912SD36040E17A-A
Heating Fuel: Gas SEER:
Primary Heat
Source Comment: COP:
Location: Conditioned A Outdoor Unit(tor heat pumps)
ECM: No "Model#: I
AHRI Certificate:7126235 #of Systems 11..
Gallons: 166 Brand: ADSm ith
Water Heater Type Heat Pump EF: 13.17 :" Model#: HPTU-66N 130
Water Heating Fuel Electric Location: (Garage or ope AHRI Certificate:
Ducts and Duct Location 'Partial oc ducts inside: ...`.n...1.
i Duct Leakage(CFM)@ 50Pa: " •
I R+E ( n r
�
Testing
Infiltration Air Changes per Hour(ACH)@ 50Pa: 259: I
Ventilation Ventilation Type HRV/ERV Model:
'Supply Side Air Cycler Airflow measured or why untestable? IlRoof Termination
Appliances
Refrigerator kWh/yr Model
ENERGY STAR Diswasher kWhryr Model
Percent High Efficacy Interior Lighting(%) 100% Thermostat
Showerhead 1.5 GPH I Showerwand 1.5 GPH I Showerhead 1.6 GPH I JShowerhead 1.75 GPH I
Notes.