Report (2) Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
, am the general contractor or the owner-builder
at the following address:
Site Address:
144 asll C*13'
City:
yhr•
Permit#: aDA-oc)
subdivision/Lot#: 50(
and/or
Map and Tax Lot#:
To conform with the 2014 Oregon Residential Specialty Code(ORSC), Section R408.1
Ventilation. lam notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
ErThe ground surface of the under-floor space is covered with 6-mil black polyethylene
sheeting with
Dioints lapped 12"at seams and
rqritending up the foundation walls 12".
Signature: Date: Le/Ao
or Owner-Bader
uilding\FormkRES-Moisturegarriendoe 09/13/2016
••••
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
I, , am the general contractor or the owner-builder
at the following address:
Site Address:
14-A 0-4 Ct II-4 A-0
City:
Permit#:
NA ST ce)V4.
Subdivision/Lot#: S'"C
and/or
Map and Tax Lot#:
To conform with the 2008 Oregon Residential Specialty Code(ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes, the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Date: S'ALP/AD
Signatu*.: -
e traotoj:or Owner-Builder
I:\Building1Form\RES-MoistureSensitiveWood.doc 09/25/08
•••••••3 411I••I•4(M4-.H4 1.0A41.41.”...41*.Sk•
.-4.
A 4
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: p\s-c--
\%-t—00(.4C) Jurisdiction.
' I
Site Address: SL-) LL,2,0k 4-0-e_
Subdivision/Lot#: ct
and/or
Map and Tax Lot#:
By my signature below, I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent,or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code N1107.2)I
Signature: Date: SicA,C0/9.0
tractor/Authorized Agent
Print Name:
1 ORSC Section N1107.2.High-efficiency interior lighting systems, A minimum of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that
has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this
requirement
The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per
input watt.
DBuillingTorms RES-HighEfficiezicyLighting.doc 07/01/08
Moffet Energy Modeling
CCB#223372
Phone: 916-342-0742
tylermoffet@moffetenergymodeling.com
Blower Door Test Affidavit
Permit#: Builder: Taylor Morrison
Site Address: Roshak Lot 59: 14217 SW 169th Ave,Tigard,OR 97224
Conditioned Floor Area (sq. ft.): 1554
Source: Calculated from plans Calculated Building Volume (cubic feet): 14970
TEST RESULTS: 990 CFM @ 50 Pa
ACH @ 50 Pa= {(CFM x 60):Volume}: 3.97
Ring: Open oA B
Minneapolis Blower Door and DG 700 Manometer
I certify that these building leakage rates are accurate and determined using standard BPI testing
protocol.
Company Name: Moffet Energy Modeling Technician:Tyler Moffet
Technician Signature: 7 404
Date: 5/21/2020