Report (28) Oregon Residential Specialty Code N1107.2
HIGII—EleFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: Jurisdiction:
PiST 1-t) 00k
Site Address:
111 4-0 et. 1.Lo-CA- A-0--A--
Subdivision/Lot#:
(5"
and/or
Map and Tax Lot#:
By my signature below, I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Spec'e ode NI 107.2)1
Signature: Date:
Own Contractor/Authorized Agent
Print Name:
ORSC Section N1107.2.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that
has a minimum efficacy of 40 lumens per input watt Screw-in compact fluorescent lamps comply with this
requirement.
The building official shall be notified in wriiing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or linear fluorescent,or a traininum efficacy of 40 lumens per
input watt.
1:113uading\Forms\RES-HighEfficiencyLighting.doc 07/0i/08
Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
_ , am the general contractor or the owner-builder
at the following address:
Site Address:
ILA 4.-C) CA
City:
Peuuit
#:
spe)kick
Subdivision/Lot#:
and/or
Map and Tax Lot#:
To conform with the 2014 Oregon Residential Specialty Code(ORSC), Section R408.1
Ventilation. I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
17rThe ground surface of the under-floor space is covered with 6-mil black polyethylene
sheeting7th
F-. Joints lapped 12"at seams and
[ ‘c-tending up th foundation walls 12".
Signature. Date:
Gene'ri Coro \tor or Owner-Builder
1:1BuildineForm1RES-MoistureBarriendoc 091/3/2016
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
( cAAr..\ - .. am the general contractor or the owner-builder
at the following address:
Site Address:
City:
Permit#:
I\XS-C 40\cl-0 0 1-Scl
Subdivision/Lot
and/or
Map and Tax Lot#:
To conform with the 2008 Oregon Residential Specialty Code(ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes,the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Signature: Date:
on tor or er-Builder
1:1Bui1dinfform\RES-MoistureSensitveWood.doc 09/25/08
QRY WALL a....1i NrUt„p�-6ON
Certificate of Compliance
This document certifies that the fiberglass insulation has been installed in conformance
with the manufacturer's recommendations and requirements to provide thermal resistance value(s)of:
R-value Thickness Coverage Area
Ceilings: X New Construction
Vaults/Slopes:
Walls: 0 Upgrade
Blown in R-23
Rim Joist:
Floors:
Over Garage
Crawl Vapor Barrier installed Y _N Sprinkler Tenting 4 mil Poly x Y _N
Loose-Fill Insulation
R- 49 using bags of insulation to cover 576 square feet of area at a thickness of 18.25 inches.
Our loose fill insulation is made by Certainteed
THERMAL PERFORMANCE-HORIZONTAL OPEN BLOW
R-VALUE BAGS PER MAXIMUM NET MINIMUM WEIGHT MINUMUM
1000 SQ.FT. COVERAGE PER SQ.FT. THICKNESS
To obtain a No.of bags per 1000 sq. Contents of this bag Weight per sq.ft.of Installed insulation
thermal resistance ft.of net area: should not cover installed insul.should should not be less j
(R)of: more than:(sq.ft.) not be less than:(lbs.) than:(in.)
60 28.9 34.5 0.897 21.75
49 23.5 42.6 0.727 18.25
44 20.8 48 0.646 16.5
38 17.9 55.7 0.556 14.5 .
30 13.8 72.5 0.427 11.5
26 11.8 84.8 0.366 10
22 9.9 101.4 0.306 8.5
19 8.6 116.2 0.267 7.5
13 5.9 170.4 0.182 5.25
11 5.0 200.5 0.155 4.5
Property Address: 14209 SW 169' Avenue Lot 58, Tigard, OR
1/08/20 Carolina Jarquin
Date of Installation ' thorization
3/26/20
Today's Date Signature
Polygon
Company/Customer Name
P.O.BOX 99*HUBBARD,OR 97032*(503)620-7036*FAX(503)624-0599*CCB#71044
Moffet Energy Modeling
CCB#223372
Phone: 916-342-0742
tylermoffet@moffetenergymodeling.com
Blower Door Test Affidavit
Permit#: Builder: Polygon
Site Address: Eastridge Lot 58: 14201 SW 169th Ave,Tigard, OR 97224
Conditioned Floor Area (sq.ft.): 1554
Source: Calculated from plans Calculated Building Volume (cubic feet): 14970
TEST RESULTS: 811 CFM @ 50 Pa
ACH @ 50 Pa = {(CFM x 60)_Volume}: 3.25
Ring: Open oA B
Minneapolis Blower Door and DG 700 Manometer
I certify that these building leakage rates are accurate and determined using standard BPI testing
protocol.
Company Name: Moffet Energy Modeling Technician: Tyler Moffet
Technician Signature: 7 Date: 3/23/2020