Report (8) _ .... .
Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
, am the general contractor or the owner-builder
at the following address:
Site Address:
t*--k LCi
City:
t ,3-a‘r•
Permit#: oct• c_i
Subdivision/Lot#:
3
and/or
Map and Tax Lot
To conform with the 2014 Oregon Residential Specialty Code(ORSC), Section R408.1
Ventilation. I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
[ f"--The ground surface of the under-floor space is covered with 6-mil black polyethylene
sheeting with
Egio-ints lapped 12"at seams and
rq-6tending up the foundation walls 12".
Signature: Date: ti
or Owner-Builder
1:\Bui1dingTorm\RES-MoistureBarrier.doc 09/13/2016
• 0tvp•ai
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: V\M- -- .J)/ Jurisdiction-
Site Address:
‘LtI3i 5 \ ( --e--
Subdivision/Lot#:
and/or
Map and Tax Lot#:
By my signature below, I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code N1107.2)1
Signature: Date:
. tractor/Authoriled Agent
Print Name:
ORSC Section N1107.2.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that
has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this
requirement.
The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per
input watt.
\BuildineForms\RES-HighEfficiencyLighting.doc 07/01/08
•
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
, am the general contractor or the owner-builder
at the following address:
Site Address:
c.cy—
ILA t31
City:
k
Permit#:
STa-C) \ck oo
Subdivision/Lot#:
and/or
Map and Tax Lot#:
To conform with the 2008 Oregon Residential Specialty Code(ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes,the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Signatuie:
Date:
cto or Owner-Builder
1:\BuilcitneForm\RES-MoisturcSanitiveWood.doc 09/25/08
Moffet Energy Modeling
CCB#223372
Phone: 916-342-0742
tylermoffet@moffetenergvmodeling.com
Blower Door Test Affidavit
Permit#: Builder: Polygon
Site Address: Eastridge Lot 53: 14131 SW 169th Ave,Tigard, OR 97224
Conditioned Floor Area (sq.ft.): 1554
Source: Calculated from plans Calculated Building Volume (cubic feet): 14970
TEST RESULTS: 891 CFM @ 50 Pa
ACH @ 50 Pa = {(CFM x 60)_Volume}: 3.57
Ring: Open O B
Minneapolis Blower Door and DG 700 Manometer
I certify that these building leakage rates are accurate and determined using standard BPI testing
protocol.
Company Name: Moffet Energy Modeling Technician: Tyler Moffet
Technician Signature: 7 1��� �+0 Date: 4/10/2020